89
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Prefix® Panel SystemMany offices desire collaboration and the ability to stay connected. Lower panels with added glass allow for natural light and interaction. From call center activity, impromptu dialogues, private conversations and open plan environments, Prefix provides just the right amount of privacy. Connect stackers to your panels, choose your favorite worksurface and add some personal storage to create an efficient and attractive aesthetic that can accommodate all your privacy needs.
Prefix panels are 21/8" thick, and can be configured in a variety of heights and fabric finishes. The ability to combine fabric base panels with glass or fabric stackers allows for multiple height, aesthetic and reconfigure options. This provides the versatility needed for today's ever changing offices spaces.
Connector posts are available in straight, extended straight, 2-Way, 3-Way, 4-Way and 120° options, provide optimal versatility and structural rigidity. Connect two stations or 10 depending upon your needs. Quick delivery and easy installation means you're up and working fast.
Worksurfaces are available with laminate to meet your budget and aesthetic needs. Prefix is manufactured in the USA and is covered by Maxon's Limited Lifetime Warranty. Workstations made easier.
90
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
TypicalsPlease refer to our typicals gallery for all Maxon systems. www.maxonfurniture.com/design-resources/typicals. Here you can download Cad files, BOM's with current pricing and PDF's of each drawing. Each month we add new ideas to support industry trends.
Use the Maxon Typicals Gallery to find the components in Prefix workstations:
Prefix “L” Station 6' x 6'
Prefix “U” Station 8' x 8'Provides seated privacy with ample storage and worksurface space
72x36-24L/24R 36x72-2
4L/24R
24x36 24x36
C1L-20 C1R-20
3636
4 4
1 2
BBF-R BBF-R
FF-R
FF-R
65X24T
65X24T65X24T
65X
24T
65X36T65X36T
65X
36T
65X
36T
65X36T65X36T
24B
IF
36F 36F
36F 36F
65L IC 65T
65T
IC
IC 65L
65E
65E
65E
65E
24TC24TC
36TC36TC
36TC
36TC
36TC36TC
3030 30
30
C1L
C1R
C1RC
1LDA
B1D
AB
1
50X48T50X48T
50X
48T
50X
48T
50X48T 50X48T
48x72-2
4L/24R
48x24
24x48
24x28-O
SC60
BBF-R
RDFF-R
4848
41
BIF
FGS-1548FGS-1548
FGS
-154
8FG
S-1
548
FGS-1548 FGS-1548
IC
50E50L
IC
50L
IC 50E
28-PB
L
91
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Prefix Panels
Doors Frameless Glass
Connector PostsAvailable in straight, extended straight, 2-Way 90° “L”, 3-Way “T”, 4-Way “X” and 120°
Monolithic Raceway*Available in fabric options
35" High 42" High 65" High50" High 65" High50" High
15" Segmented Raceway Glass Upper*Available in fabric base
15" Glass Stacker
15" Fabric Stacker
Glass and Fabric Stackers
30" Glass Stacker
Sliding Door Hinge Door
24"W
35"H
15"H
421⁄2"H
50"H
65"H
30"W 36"W 42"W 48"W 60"W 72"W
24"W
35"H
15"H
421⁄2"H
50"H
65"H
30"W 36"W 42"W 48"W 60"W 72"W
Extended Straight
2-Way 900 "L"
120° 2-Way
3-Way "T"
4-Way "X"
120° 3-Way
92
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Working with Prefix Panels
Top trim is relocated from base panel frame.
Structural panel frames are available in 35", 421⁄2", 50", and 65" nominal heights.
Stacking panels are available in 15"H tackable or glazed and 30"H glazed. Frameless glass screens are also available for topping off panels in 71⁄2" or 15"H, select either clear or frosted glass.
Panels are 21⁄8" nominal thick, (use 21⁄4" to calculate inter-sections in length of panel runs).
Lay-in base pathwayaccepts voice, data and
fiber optic cable, as well as electrical system.
Base pathway cover has outlet openings that accept duplex receptacles or commercially avai lable modular data faceplates.
Leveling glides provide 21⁄8" of adjustment.
Frame Dimensions (Actual)
Depth: 21⁄8" (use 21⁄4" to calculate intersections in length of panel run)
Widths: 20", 24", 30", 36", 42", 48", 60", 72"
Heights: 341⁄4", 413⁄4", 491⁄4", 641⁄4" (with levelers fully retracted)
Leveling Glides: 21⁄8" range
Stacking Panels: 15"H fabric and glass, 30"H glass
Frameless Glass: 71⁄2" H Top of Glass to Extrusions, 81⁄4"H Top of Glass to Top of Top Cap, 15" H Top of Glass to Extrusions , 16"H Top of Glass to Top of Top Cap
Inline connections between panels in a continuous run are accomplished with an inline connector kit.
Panel frames are shipped with base pathway covers installed.
93
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Building Vertically with Prefix Panels
Tackable Panels ∙ Specifications: 4-sided, welded tubular steel panel frame. ∙ Hardware included with connector kits. ∙ Available in 4 heights and 8 widths — add 3/8" for each panel vertical
end trim. ∙ Panel frames can be leveled up to 21/8". Actual panel height varies
depending on position of leveling glides. ∙ Direct connections between same height frames in a continuous run
are accomplished with provided hardware. There is no incremental increase in dimension along the run.
∙ For adequate stability, one of two methods of stabilization shown on page 94 must be adhered to.
∙ Due to depth of panel, back-to-back data modules should not be used in the base.
∙ Add 21/4" to panel run for each “L”, “T”, “X”, or extended straight connector (“S”).
∙ Acoustical panels meet BIFMA recommendations.
Tackable Glass Panels ∙ Available 50"H and 65"H with 15"H clear or frosted tempered safety
glass inserts (specified). ∙ Glass frame is painted to match trim. ∙ Top trim is specified separately. ∙ Cannot stack on glass panels. ∙ Glass is not load bearing/no overheads can be mounted.
Stacking Fabric and Glass Stackers ∙ Stacking connection provides a solid connection, allowing the stacking
frame to accept hang-on components, per Prefix configuration guidelines.
∙ Includes attachment hardware. Specify connectors separately. ∙ Only one Glass Stacker can be added to top position of any Prefix panel
of same width from 20"W to 72"W up to a maximum combined height of 80".
∙ End trim is specified in full end height to include height of base panel + stacking panel.
∙ Guidelines for using overhead storage with Stackers are given on pages 123-124.
∙ Glass Stackers feature clear or frosted tempered safety glass inserts (specified). Glass frame is painted to match trim.
∙ Stacking frames can be added to base frames of the same width to achieve a maximum height of 80"H. Stackers can be added to 421⁄2"H Base Frames to achieve heights of 571⁄2"H and 721⁄2"H.
∙ Slot modularity will be lost on Stacker used with 421⁄2"H panels. If panel mounting slots are not being used, this is not an issue.
∙ Stackers must match the width of the base frame and are unable to span multiple panels.
∙ Stacking frames cannot be used as base frames. ∙ Glass Stackers must be installed at top portion. ∙ Cannot double stack Glass Stackers. ∙ Stackers cannot be used on Top Tier Glass Panels. ∙ Only one 15" and 30" Glass Stacker can be used on a panel. ∙ Fabric Stackers cannot be used on top of a Glass Stacker.
Standard Top Cap ∙ Specified separately. ∙ It is possible to span multiple panels when the combined panel width is
equal to the top cap width.
Frameless Glass Top Cap ∙ Frameless insert integrated into the base panel frame top trim. ∙ Replaces top trim on structural or Fabric Stacker. ∙ It is possible to span multiple frames when the combined frame width
is equal to the panel mounted screen width. ∙ Cannot do variable height, must go on highest panel(s). ∙ Frameless glass screens are non-structural. ∙ Do not hang or stack on top of frameless glass screens. ∙ Available in clear or frosted glass and heights of 7.5" or 15". ∙ Made with 3/8" thick laminated tempered safety glass. ∙ To be included in overall height of panel with a maximum combined
height of 80". ∙ Unit itself serves as the top cap. Top cap does not need to be ordered. ∙ Can not be used on Glass Stacker or Glass Panels. ∙ Can be used as a marker board on both sides.
94
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Building Horizontally with Prefix PanelsImportant planning guidelines: For adequate stability, one of two methods of stabilization must be adhered to:
Definitions:Parent Panel Run (Spine) – Panels (or a single panel) configured in a straight line intended to divide space. Parent panel runs greater than 60".
Return Panels – Panels attached to a parent run for the purpose of stability. Return panels may also have the effect of dividing space.
Note: Return panels must be no more than 30" lower than the maximum height of the parent panel run. When stacking, the maximum height allowed is 80". This includes frameless glass. If attaching overhead storage, return panels must be the same height as parent run.
W
Method 1 — Opposing returns ∙ A parent run must be a minimum of 48" and a maximum of
144" between return panels. ∙ The parent run must have a minimum of two 24"W return
panels running in opposing directions on each end of run. ∙ Return panels must not be any more than 30" shorter in height
than parent run. ∙ Any panel run greater than 60" is considered a spine. ∙ When using 120° connectors, 12" must be added to length of
return panels as determined by methods 1 and 2.
Method 1
Parent Run Length Minimum Return Panels
Minimum Return Panel Widths with
Stack-Ons
48"-108" 20" 20"
114"-144" 24" 24"
X
Y
Method 2 — Single-sided returns ∙ A parent run must be a minimum of 48" and a maximum of
144" between return panels. ∙ The parent run must have a minimum of two return panels
extending in one direction. Stack-ons may require additional length.
∙ Return panels must not be any more than 30" shorter in height than parent run.
∙ Any panel run greater than 60" is considered a spine. ∙ When using 120° connectors, 12" must be added to length of
return panels as determined by methods 1 and 2.
Method 2
Parent Run LengthMinimum
Return Panels Total (X+Y)
Minimum Return Panel Widths with
Stack-Ons Total (X+Y)
48"-108" 84" 84"
114"-144" 84" 96"
Door Panel Frame ∙ The 80"H door panel frame includes 42"W
frame, 36"W laminate door. ∙ Door panel frame comes with hinges and
attaching hardware. ∙ Immediate adjacent panels must be equal
in height to the door panel frame. ∙ Lockset with lever ordered separately. ∙ Keyed alike option not available on door
panels. ∙ Door is non-handed. For left or right
hand: change to desired swing at time of installation.
∙ Top Cap ordered separately.
Sliding Doors and Mounting Kits ∙ Frosted Translucent Acrylic door. ∙ Sliding doors are available in 50"H, 65"H,
and 80"H. ∙ Sliding doors are 42" wide to cover a 36"
wide opening. ∙ Must connect to a panel of equal or taller
height. ∙ See illustration and specification informa-
tion on page "Working with Sliding Doors" on next page.
∙ Sliding Door Kits must be ordered separately.
95
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Working with Sliding DoorsSliding doors for Prefix are a great addition to any new or existing installations. The sliding door can be specified with specific mounting kits for each door ordered. With a Frosted Translucent insert and your choice of P1 or P2 paint, the sliding door will create a unique look for any office environment.
The sliding doors are available in 50", 65", and 80"H models and can mount to 30", 36", 42", and 48"W panels. They accommodate a 36"W opening and are 42"W, nominally. The door ships from the factory non-handed and can be installed in either right or left handed applications. The handle pulls located on each side of the door are non-locking and are color matched to the trim to create a uniform style. And with the threshold free design, the sliding door offers better aesthetics and safety by eliminating the potential for tripping.
General Guidelines for Use of Sliding Door ∙ The system requires the ordering of both a door and a mounting bracket kit. ∙ All doors are 42" wide to accommodate a 36"W opening and are non-handed. Door leveling is dependant on floor being level. ∙ A mounting bracket kit must be ordered for each door corresponding to the mounting panels width (30", 36", 42", or 48"W). ∙ Mounting bracket kits are system specific and for Prefix.
General Guidelines for Layout Planning of Sliding Door ∙ Stability guidelines must be followed when specifying a sliding door. The sliding door system was designed to close an opening in a
run of lateral panels. Doors mounted to long runs of panels without floor support, ties to worksurfaces, or return panels may seem less stable
If the door is used to close an opening (A) where the panel opposite the door is at 90°, there will be a gap equal to the panel thickness between the door and the panel end when closed. To close this gap, an Extended Straight Connector should be specified as shown.
If back-to-back doors are mounted on panels (C) that are less than 42"W they will interfere with each other if both are open at the same time.
When planning the layout, care must be taken if the plan includes a door mounted on a panel that is less than 42"W. If the panel is at a corner (B), the door will protrude into the aisle or next workstation when in the open position.
The slide door is designed to be attached to an end of run panel only. The slide door should not be specified on a panel that is connected on both ends, regardless if one of those ends is connecting to a connector kit. Failure to abide by this rule will result in a failure to install the door.
If the door is mounted to a panel run that is positioned adjacent to a wall (E) inside a 90° angle there must be 42" clearance between the track stop and the wall/inside 90°.
The door is attached at the base of the panel at any end position with a wrap around bracket. Bracket kits are ordered in conjunction with appropriate end trim profiles. The slots at the base of the panel must be clear (D) and cannot be utilized by worksurface supports or panel hung components.
If a door is closing an opening of a workstation that includes a “T” connector in the opposite wall, an extended straight connector may need to be used to maintain the 36" required opening.
To provide additional panel stability when sliding doors are specified, worksurface support in the form of worksurface bracket kits or spanner rails are suggested.
96
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Hinged Door
Best placement of a door is at an L, T, X connector or wall starter connector for rigidity.
Use of spanning top caps at an inline will also help add additional rigidity.
Door frame is 42"WLaminate Door Opening is 36"W.
Wall starts should be used if panels are not required along the wall.
65X36T
65X36T
65X36T65X36T65X36T
42X80D
oor
65X
36T
65X
30T
65X36T
15X36T
15X36T
15X36T
15X36T15X36T15X36T
15X
36T
15X
30T
IC
IC
ICIC
80L
IC IC
80L
36TC36TC
36TC36TC36TC
36TC
30TC
36TC
42TC
80W
80W
24x66
24x48
FB24
C1L
FEP
FEP
C1L
-20
42X80Door42TC
3'-6"
3'-0"
65X36T 65X36T 65X36T
65X36T
65X36T
65X36T
65X36T65X36T65X36T
42X80D
oor
65X
30T
65X
36T
15X36T 15X36T 15X36T
15X36T
15X36T
15X36T
15X36T15X36T15X36T
15X
30T
15X
36T
IC
80L
IC
80L
IC IC
80L
ICIC
80L
ICIC
36TC 36TC 36TC
36TC36TC
36TC
36TC36TC36TC
42TC
30TC
36TC
65X36T 65X36T 65X36T
65X36T65X36T65X36T
42X80D
oor
65X
30T
65X
36T
15X36T 15X36T 15X36T
15X36T15X36T15X36T
15X
30T
15X
36T
IC
80L
IC
80L
IC IC
ICIC
36TC 36TC 36TC
36TC36TC36TC
42TC
30TC
36TC
80W
80W
97
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Connectors and TrimIntersecting Connectors
“S”, Connector Kits ∙ Specify post height as height of tallest
panel at the connection. ∙ Extended straight connector kit “S”
can be used to keep continuous runs dimensionally consistent with opposing panel runs which incorporate “T” or “X” intersections.
∙ Add 2 ¼" to the length of the run for every extended straight connector used.
“L” 90°
“X” 4-Way
“T” 3-Way
“L”, “T”, “X”, Connector Kits ∙ Specify post height as height of tallest panel
at the connection. ∙ “L”, “T”, and “X” connector kits are used
when connecting panels at intersecting runs. For “L”, “T”, and “X” connector kits, add 2 ¼" to the total length of the panel run for each intersection, whether located in the middle or at the end of the run.
∙ Includes transition piece, connectors, vertical cover(s), and attaching hardware.
50"HPanel Frame
65"HPanel
1 – 15"H StackingPanels
Example 3Connectors required:1–65"H “L”
Inline Connectors
Inline Connector Kit ∙ Inline connections between panels in
a continuous run are accomplished with an inline connector kit. There is no incremental increase in dimension along the run.
∙ Inline connector kits include all parts required for connecting two panels of same height together.
∙ Kit includes inline connector strap, hardware, and glide tower to glide tower screw.
∙ Order panel end trim kits to finish the end of every panel run (except when attaching panels to permanent walls).
Inline Variable Height End Trim Finish Kits ∙ Includes connectors, vertical cover, and
attaching hardware. ∙ High-low “H” covers the exposed end
of a panel when joining panels inline of differing heights.
∙ Order one per each panel height change in an inline connection. (See example 5 for application.)
35"H
50"H
Example 1Connectors required:1–50"H “T” 1–15"H “VH”
P3CONVH1565"H
50"H
P3CONL65
Example 4
M-PFXC-15HL
M-PFXC-65L
Finish ConnectorsPanel End Trim ∙ End vertical trim cover (includes top cap —
adds 3⁄8" to run). ∙ Order to finish the end of every panel
run (except when attaching panels to permanent walls).
Variable Height Connector Kits — Post Trim ∙ Includes connectors, vertical cover, and
attaching hardware. ∙ Order one per each panel height change in
an “L”, “T”, “X”, or “S”.
Multiple-Height Connections ∙ Multiple-height connections also utilize
standard “L”, “T”, “X”, and “S” connectors, in the height of the tallest panel. (See examples 1-4)
Wall Mount Kits ∙ Specify post height as height of tallest
panel at the connection. ∙ M-PFXC-65YEB is a pair of ends.
M-PFXC-65YM is the middle unit. ∙ All wall track system worksurfaces must be
floor supported by an end panel, pedestal or lateral file, with one floor support at each end of the worksurface run and a maximum spacing of 8' between floor supports.
∙ Not recommended for masonry. ∙ Wall mount kits provide a means to affix a
panel run to a permanent building wall. ∙ Includes top cap.
(Color must be specified.) ∙ Connector adds 1" to length of panel run. ∙ Anchor devices are not supplied with the
wall mount kit. Refer to Prefix Installation Instructions for appropriate hardware.
50"H
65"H
35"H421⁄2"H
Example 2Connectors required:1–65"H “X” 1–15"H “VH”1–221⁄2"H “VH”1–30"H “VH”
Example 5
98
Prefix® Panel System GSA SIN 711-1
See pages 90-97 for the specification guide.All Actual Dimensions are listed on page 92. Pricing listed below for P1 Paint. P2 Paint finishes apply a 10% of LIST upcharge.
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Standard Monolithic Tackable Fabric — Panel
Description Model H W Wt. Cubes Grade A Fabric
Grade B Fabric
Standard Monolithic Tackable Fabric 35"H
M-PFXM-3520FP 35" 20" 20.2 1 509 523M-PFXM-3524FP 35" 24" 21.8 1.2 515 529M-PFXM-3530FP 35" 30" 23.5 1.5 520 534M-PFXM-3536FP 35" 36" 25.2 1.8 525 539M-PFXM-3542FP 35" 42" 26.9 2.1 531 546M-PFXM-3548FP 35" 48" 28.6 2.4 534 549M-PFXM-3560FP 35" 60" 30.3 3 632 650M-PFXM-3572FP 35" 72" 32 3.6 707 727
Standard Monolithic Tackable Fabric 42.5"H
M-PFXM-4220FP 42.5" 20" 22 1.2 577 592M-PFXM-4224FP 42.5" 24" 24.8 1.5 586 601M-PFXM-4230FP 42.5" 30" 27.5 1.8 593 609M-PFXM-4236FP 42.5" 36" 30.3 2.2 603 619M-PFXM-4242FP 42.5" 42" 33.1 2.6 621 638M-PFXM-4248FP 42.5" 48" 35.8 3 640 658M-PFXM-4260FP 42.5" 60" 38.6 3.7 769 790M-PFXM-4272FP 42.5" 72" 41.4 4.4 862 885
Standard Monolithic Tackable Fabric 50"H
M-PFXM-5020FP 50" 20" 23.4 1.4 603 619M-PFXM-5024FP 50" 24" 26.9 1.7 629 645M-PFXM-5030FP 50" 30" 30.5 2.2 655 672M-PFXM-5036FP 50" 36" 34 2.6 697 716M-PFXM-5042FP 50" 42" 37.5 3 739 759M-PFXM-5048FP 50" 48" 41.1 3.5 782 803M-PFXM-5060FP 50" 60" 44.6 4.3 935 960M-PFXM-5072FP 50" 72" 48.2 5.2 1047 1075
Standard Monolithic Tackable Fabric 65"H
M-PFXM-6520FP 65" 20" 30.3 1.9 619 635M-PFXM-6524FP 65" 24" 34.9 2.3 651 668M-PFXM-6530FP 65" 30" 39.5 2.8 689 707M-PFXM-6536FP 65" 36" 44.2 3.4 735 757M-PFXM-6542FP 65" 42" 48.8 3.9 766 786M-PFXM-6548FP 65" 48" 53.4 4.5 809 831M-PFXM-6560FP 65" 60" 58 5.6 951 977M-PFXM-6572FP 65" 72" 62.6 6.8 1064 1092
HOW TO SPECIFYSelect Model Number Select Fabric
See pages 15-16
Select Trim Color
See page 14
M - . .
99
Prefix® Panel SystemGSA SIN 711-1
See pages 90-97 for the specification guide.All Actual Dimensions are listed on page 92. Pricing listed below for P1 Paint. P2 Paint finishes apply a 10% of LIST upcharge.
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Tackable Glass — PanelIncludes ∙ Assembled panel with glass.
List List
Description Model H W Wt. Cubes Grade A Fabric
Grade B Fabric
Grade A Frosted
Glass
Tackable Glass Panel 50"H with 15"H Glass
M-PFXH-5020FGP 50" 20" 20.8 1.5 819 840 861M-PFXH-5024FGP 50" 24" 23.4 1.8 898 921 943M-PFXH-5030FGP 50" 30" 26.7 2.2 977 1002 1027M-PFXH-5036FGP 50" 36" 30.5 2.6 1053 1080 1107M-PFXH-5042FGP 50" 42" 34.4 3 1113 1142 1172M-PFXH-5048FGP 50" 48" 38.8 3.4 1131 1162 1194M-PFXH-5060FGP 50" 60" 46 4.3 1375 1411 1446M-PFXH-5072FGP 50" 72" 55.2 5.1 1591 1632 1673
Tackable Glass Panel 65"H with 15"H Glass
M-PFXH-6520FGP 65" 20" 23.8 2 951 975 999M-PFXH-6524FGP 65" 24" 26.6 2.3 1043 1069 1095M-PFXH-6530FGP 65" 30" 30.4 2.8 1144 1173 1202M-PFXH-6536FGP 65" 36" 34.3 3.4 1241 1273 1304M-PFXH-6542FGP 65" 42" 38.8 3.9 1344 1378 1413M-PFXH-6548FGP 65" 48" 43.2 4.4 1447 1484 1521M-PFXH-6560FGP 65" 60" 50.7 5.5 1659 1702 1744M-PFXH-6572FGP 65" 72" 60.3 6.5 1921 1970 2019
HOW TO SPECIFYSelect Model Number Select Fabric
See pages 15-16
Select Trim Color
See page 14
Select Glass
C Clear GlassFT Frosted Glass
M - . . .
100
Prefix® Panel System GSA SIN 711-1
See pages 90-97 for the specification guide.All Actual Dimensions are listed on page 92. Pricing listed below for P1 Paint. P2 Paint finishes apply a 10% of LIST upcharge.
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Glass StackersIncludes ∙ Assembled glass stacker.
List List
Description Model H W Wt. Cubes Clear Glass
Frosted Glass
Glass Stacker 15"H M-PFXS-1520G 15" 20" 8.3 1.9 521 546M-PFXS-1524G 15" 24" 9.4 1.9 571 599M-PFXS-1530G 15" 30" 10.9 1.9 645 677M-PFXS-1536G 15" 36" 12.5 2.2 666 699M-PFXS-1542G 15" 42" 14.1 2.6 740 776M-PFXS-1548G 15" 48" 15.7 2.9 795 834M-PFXS-1560G 15" 60" 18.8 3.6 909 954M-PFXS-1572G 15" 72" 22 4.3 1074 1126
Glass Stacker 30"H M-PFXS-3020G 30" 20" 14.3 3.3 542 569M-PFXS-3024G 30" 24" 16.8 3.3 593 623M-PFXS-3030G 30" 30" 19.8 3.3 665 699M-PFXS-3036G 30" 36" 23 3.8 686 721M-PFXS-3042G 30" 42" 26.2 4.4 755 793M-PFXS-3048G 30" 48" 29.4 4.9 811 852M-PFXS-3060G 30" 60" 35.6 6.2 921 968
HOW TO SPECIFYSelect Model Number Select Trim Color
See page 14
Select Glass
C Clear GlassFT Frosted Glass
M - . .
101
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
See pages 90-97 for the specification guide.All Actual Dimensions are listed on page 92.
Fabric Stackers (Tackable)Includes ∙ Assembled fabric stacker.
Description Model H W Wt. Cubes Grade A Fabric
Grade B Fabric
Fabric Stacker 15"H (tackable)
M-PFXS-1520F 15" 20" 6 1.9 429 435M-PFXS-1524F 15" 24" 6.8 1.9 460 467M-PFXS-1530F 15" 30" 8.1 1.9 496 503M-PFXS-1536F 15" 36" 9.3 2.2 534 542M-PFXS-1542F 15" 42" 10.5 2.6 574 582M-PFXS-1548F 15" 48" 11.7 2.9 615 624M-PFXS-1560F 15" 60" 14.2 3.6 693 703M-PFXS-1572F 15" 72" 17.2 4.3 803 815
Prefix Panel Top Cap
List List
Description Model W Wt. Cubes P1 P2
Prefix Panel Top Cap M-PFXTC20 20" 2 0.3 46 51M-PFXTC24 24" 2 0.3 46 51M-PFXTC30 30" 2 0.3 58 64M-PFXTC36 36" 2 0.3 75 83M-PFXTC42 42" 2 0.4 88 97M-PFXTC48 48" 3 0.5 96 106M-PFXTC60 60" 4 0.6 108 119M-PFXTC72 72" 4 0.7 114 125
HOW TO SPECIFYSelect Top Cap Model Number Select Trim Color
See page 14
M - .
HOW TO SPECIFYSelect Fabric Stacker Model Number Select Fabric
See pages 15-16
M - .
102
Prefix® Panel System GSA SIN 711-1
See pages 90-97 for the specification guide.All Actual Dimensions are listed on page 92. Pricing listed below for P1 Paint. P2 Paint finishes apply a 10% of LIST upcharge.
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Frameless GlassIncludes ∙ Frameless Glass which replaces need for top cap.
List List
Description Model H W Wt. Cubes Clear Glass
Frosted Glass
Frameless Glass 7"H M-PFXFGS-0720 7.5" 20" 18 0.7 421 458M-PFXFGS-0724 7.5" 24" 20 0.8 481 521M-PFXFGS-0730 7.5" 30" 22 1 538 581M-PFXFGS-0736 7.5" 36" 24 1.2 558 605M-PFXFGS-0742 7.5" 42" 26 1.4 599 649M-PFXFGS-0748 7.5" 48" 28 1.6 646 699M-PFXFGS-0754 7.5" 54" 30 1.8 678 735M-PFXFGS-0760 7.5" 60" 32 2 715 775M-PFXFGS-0766 7.5" 66" 34 2.2 780 843M-PFXFGS-0772 7.5" 72" 36 2.4 816 883
Frameless Glass 15"H M-PFXFGS-1520 15" 20" 18 0.7 451 491M-PFXFGS-1524 15" 24" 20 0.8 511 554M-PFXFGS-1530 15" 30" 22 1 588 635M-PFXFGS-1536 15" 36" 24 1.2 631 681M-PFXFGS-1542 15" 42" 26 1.4 707 760M-PFXFGS-1548 15" 48" 28 1.6 781 838M-PFXFGS-1554 15" 54" 30 1.8 871 931M-PFXFGS-1560 15" 60" 32 2 924 987M-PFXFGS-1566 15" 66" 34 2.2 979 1046M-PFXFGS-1572 15" 72" 36 2.4 1021 1091
HOW TO SPECIFYSelect Model Number Select Trim Color
See page 14
Select Glass
C Clear GlassFT Frosted Glass
M - . .
103
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
See pages 90-97 for the specification guide.
Sliding Door
List List
Description Model H W Wt. Cubes P1 P2
Prefix Sliding Door M-PFXSD5042 50" 42" 28 5.5 1687 1856M-PFXSD6542 65" 42" 38 7.1 1758 1934M-PFXSD8042 80" 42" 46 8.6 1826 2009
Sliding Door Mounting Kit
List List
Description Model W Wt. Cubes P1 P2
Prefix sliding door mounting kit M-PFXSDKIT30 30" 4 0.4 265 292M-PFXSDKIT36 36" 5 0.5 284 312M-PFXSDKIT42 42" 6 0.5 302 332M-PFXSDKIT48 48" 7 0.5 313 344
HOW TO SPECIFYSelect Model Number Select Trim Color
See page 14
M - .
104
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
See pages 90-97 for the specification guide.All Dimensions are Nominal.
Hinged Door Kits
List List
Description Model H W Wt. Cubes P1 P2
Prefix Door Panel - NO Top Cap M-PFXDP8042P 80" 42" 155 7.3 2154 2369
Top Cap not included with door
Description Model H W Wt. Cubes List
Door Lever M-DOORLEVER 6" 10" 2 0.1 424
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
Select Door Laminate
See page 19
M - . .
105
Prefix® Panel SystemGSA SIN 711-1
See pages 90-97 for the specification guide.All Dimensions are Nominal.
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Extended Straight ConnectorIncludes ∙ Connector post, post cap, 2 panel to post connectors and hardware.
List List
Description Model H Wt. Cubes P1 P2
Extended Straight Connector M-PFXC-35S 35" 1.8 0.5 159 175M-PFXC-42S 42.5" 2.3 0.5 171 188M-PFXC-50S 50" 2.7 0.6 182 200M-PFXC-57S 57.5" 3.2 0.8 195 215M-PFXC-65S 65" 3.6 0.8 207 228M-PFXC-72S 72.5" 4 0.9 217 239M-PFXC-80S 80" 4.5 0.9 232 255
"L" ConnectorIncludes ∙ Connector post, post cap, 2 panel to post connectors and hardware.
List List
Description Model H Wt. Cubes P1 P2
"L" Connector M-PFXC-35L 35" 1.8 0.5 159 175M-PFXC-42L 42.5" 2.3 0.5 171 188M-PFXC-50L 50" 2.7 0.6 182 200M-PFXC-57L 57.5" 3.2 0.8 195 215M-PFXC-65L 65" 3.6 0.8 207 228M-PFXC-72L 72.5" 4 0.9 217 239M-PFXC-80L 80" 4.5 0.9 232 255
HOW TO SPECIFYSelect Model Number Select Trim Color
See page 14
M - .
106
Prefix® Panel System GSA SIN 711-1
See pages 90-97 for the specification guide.All Dimensions are Nominal.
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
"T" ConnectorIncludes ∙ Connector post, post cap, 3 panel to post connectors and hardware.
List List
Description Model H Wt. Cubes P1 P2
"T" Connector M-PFXC-35T 35" 1.8 0.5 159 175M-PFXC-42T 42.5" 2.3 0.5 171 188M-PFXC-50T 50" 2.7 0.6 182 200M-PFXC-57T 57.5" 3.2 0.8 195 215M-PFXC-65T 65" 3.6 0.8 207 228M-PFXC-72T 72.5" 4 0.9 217 239M-PFXC-80T 80" 4.5 0.9 232 255
"X" Connector
Includes ∙ Connector post, post cap, 4 panel to post connectors and hardware.
List List
Description Model H Wt. Cubes P1 P2
"X" Connector M-PFXC-35X 35" 1.8 0.5 159 175M-PFXC-42X 42.5" 2.3 0.5 171 188M-PFXC-50X 50" 2.7 0.6 182 200M-PFXC-57X 57.5" 3.2 0.8 195 215M-PFXC-65X 65" 3.6 0.8 207 228M-PFXC-72X 72.5" 4 0.9 217 239M-PFXC-80X 80" 4.5 0.9 232 255
HOW TO SPECIFYSelect Model Number Select Trim Color
See page 14
M - .
107
Prefix® Panel SystemGSA SIN 711-1
See pages 90-97 for the specification guide.All Dimensions are Nominal.
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Prefix 120° 2-Way ConnectorIncludes ∙ Connector post, 120° post cap, 2 panel to post connectors and hardware.
List List
Description Model H Wt. Cubes P1 P2
Prefix 120° 2-Way Connector M-PFXC-35V 35" 6 0.4 169 186M-PFXC-42V 42.5" 6 0.4 182 200M-PFXC-50V 50" 6 0.6 197 217M-PFXC-57V 57.5" 8 0.7 208 229M-PFXC-65V 65" 8 0.7 222 244M-PFXC-72V 72.5" 9 0.9 235 259M-PFXC-80V 80" 9 0.9 247 272
Prefix 120° 3-Way ConnectorIncludes ∙ Connector post, 120° post cap, 3 panel to post connectors and hardware.
List List
Description Model H Wt. Cubes P1 P2
Prefix 120° 3-Way Connector M-PFXC-35Y 35" 6 0.4 169 186M-PFXC-42Y 42.5" 6 0.4 182 200M-PFXC-50Y 50" 6 0.6 197 217M-PFXC-57Y 57.5" 8 0.7 208 229M-PFXC-65Y 65" 8 0.7 222 244M-PFXC-72Y 72.5" 9 0.9 235 259M-PFXC-80Y 80" 9 0.9 247 272
HOW TO SPECIFYSelect Model Number Select Trim Color
See page 14
M - .
108
Prefix® Panel System GSA SIN 711-1
See pages 90-97 for the specification guide.All Dimensions are Nominal.
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Straight Connector Kit
Includes ∙ Panel-to-panel connector and hardware.
Description Model Wt. Cubes List
Straight Connector Kit M-PFXC-S 0.0 1 12
Panel End CoversIncludes ∙ End trim, connector, hardware and end trim clips.
List List
Description Model H Wt. Cubes P1 P2
Panel End Covers M-PFXC-35E 35" 3 0.5 87 96M-PFXC-42E 42.5" 3 0.5 92 101M-PFXC-50E 50" 4 0.6 96 106M-PFXC-57E 57.5" 5 0.8 101 111M-PFXC-65E 65" 5 0.8 106 117M-PFXC-72E 72.5" 6 0.9 111 122M-PFXC-80E 80" 6 0.9 117 129
HOW TO SPECIFYSelect Model Number Select Trim Color
See page 14
M - .
109
Prefix® Panel SystemGSA SIN 711-1
See pages 90-97 for the specification guide.All Dimensions are Nominal.
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Panel Wall Mount KitIncludes ∙ Wall mount, wall mount top cap, panel to wall mount connector and hardware.
List List
Description Model H Wt. Cubes P1 P2
Panel Wall Mount Kit M-PFXC-35W 35" 4 0.5 182 200M-PFXC-42W 42.5" 4 0.5 203 223M-PFXC-50W 50" 5 0.6 221 243M-PFXC-57W 57.5" 6 0.8 236 260M-PFXC-65W 65" 6 0.8 254 279M-PFXC-72W 72.5" 7 0.9 267 294M-PFXC-80W 80" 7 0.9 282 310
Panel Wall Strip KitIncludes ∙ Wall mount and hardware.
List List
Description Model H Wt. Cubes P1 P2
Panel Wall Mount Kit M-PFXC-65YEB 65" 6 0.7 216 238M-PFXC-65YM 65" 3 0.7 209 230
HOW TO SPECIFYSelect Model Number Select Trim Color
See page 14
M - .
110
Prefix® Panel System GSA SIN 711-1
See pages 90-97 for the specification guide.All Dimensions are Nominal.
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Variable Height Connector KitIncludes ∙ Connector, trim and hardware.
List List
Description Model H Wt. Cubes P1 P2
Variable Height Connector Kit
M-PFXC-07HL 7.5" 2 0.2 87 96M-PFXC-15HL 15" 2 0.4 92 101M-PFXC-22HL 22.5" 3 0.4 106 117M-PFXC-30HL 30" 3 0.4 127 140
In-Line Variable Height Finishing KitIncludes ∙ Trim cap, trim and hardware.
List List
Description Model H Wt. Cubes P1 P2
In-Line Variable Height Finishing Kit
M-PFXC-07HLS 7.5" 2 0.2 87 96M-PFXC-15HLS 15" 2 0.4 92 101M-PFXC-22HLS 22.5" 3 0.4 107 118M-PFXC-30HLS 30" 3 0.4 127 140
HOW TO SPECIFYSelect Model Number Select Trim Color
See page 14
M - .
111
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Electrical Specification Information
Base pathway accommodates
power and lay-in capacity for data and
communication.
Fiber optic cables can follow 90° turns at the intersection of panel runs.
Electrical power harness accepts up to 2 duplex recepta-cles per panel side (24"W limited to 1) at base pathway.
Base pathway power in-feed mounts into any receptacle position in the base pathway area and is connected to the building electrical supply.
Ceiling in-feed connects to building electrical supply. Ceiling in-feed can also be used at the bottom to feed up into panel where permitted by codes. This in-feed can be prewired before panels are installed. M-EPF3 in-feed must be installed in panel before connecting to building wiring.
Integrated power pole accommodates power in-feed and communication/data lines.
Power blocks snap into base pathway
horizontal frame members and accept
duplex receptacles.
Single block pass- thru harnesses have
capacity for one duplex receptacle
per panel side.
112
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Byrne Electrical System Capabilities ∙ Prefix features a Byrne 4-circuit/8-wire modular power distribution
system. The standard power configuration provides three utility circuits, which share a common Neutral and Ground, plus an isolated/dedicated fourth circuit, with an independent Neutral and Ground. As an option, the system can also provide 2 utility circuits + 2 isolated circuits.
∙ The power distribution system provides access to multiple electrical outlets and circuits within the same panel.
∙ The standard power distribution through the base-level raceway can branch electrical service up to the work surface level as needed.
∙ Each electrical circuit is rated 120volts/20amp. Up to four 20 Amp circuits may be accessed from a 3-phase power source, and up to three circuits may be used with a single-phase source.
∙ The electrical system is UL LISTED.
NOTE ON THE SPECIFICATION AND INSTALLATION OF ELECTRICAL COMPONENTS
The Maxon 4-Circuit/8-Wire power system conforms to National Electrical Code requirements. However, some variations may exist in the local authority of electrical code standards. The specifier or user is responsible for confirming code standard compliance in these locations before specification and ordering. The availability of power components and systems does not constitute local code approved by Maxon Furniture Inc.
All electrical installation work on Maxon power systems should be done under the supervision of a licensed electrician or approved electrical contractor.
Electrical SystemsPrefix Electrical SystemsPrefix offers a choice of two electrical systems:
∙ Four-circuit, 3 + 1 ∙ Four-circuit, 2 + 2
∙ Both systems utilize an 8-wire electrical system, rated at 20 amps per circuit (15 amps Canadian).
∙ Prefix panels and electrical components are UL Listed. Electrical components are also CSA certified.
∙ Installation and use of the electrical system, the number of recep tacles used on a given circuit, and connections to the building power supply should be in compliance with all local and national electrical codes.
Caution: Electrical equipment cords or extension cords MUST NOT BE ROUTED through panels.
Hardwire Junction Box – New York Code (page 121) ∙ Hardwire (New York Code)
junction box (model M-EPFX) is used when local electrical codes require hardwire entry.
∙ For use in panels 30"W to 72"W. ∙ When used in 30"W and 36"W panels, power can be routed
only in one direction. ∙ When used in 42" and wider panels, an electrical pass-thru
or power harness the same width as the panel can be used to route power back in the opposite direction.
∙ Unit must connect to a power or pass-thru harness positioned in the base pathway area of an adjacent panel.
Hardwire Chicago Code (page 121) ∙ Wiring Harnesses and snap connectors are not allowed in
Chicago — base pathways must be comprised of all metallic compo nents.
∙ The base pathway junction box (model M-ECH1) clips directly into receptacle locations for single sided applications.
∙ Customer must furnish conduit, wiring, and designer-type receptacles for the base pathway.
∙ Power entry can be routed from the ceiling, via Prefix power pole, or from the floor into a junction box (model M-ECH1).
∙ Junction box can be positioned at any duplex receptacle location.
∙ Cannot be used in back to back applications.
Electrical In-Feeds ∙ Power in-feed cables deliver power from building to panel's electrical
system. ∙ In-feed cables are housed in conduit to separate electrical system from
communications and data lines. ∙ Select quantity of base or ceiling in-feed cables depending on
individual power requirements.
Base Pathway Power In-feed ∙ M-EPF2 - (72" Long) For use in all Maxon Panel
Systems to connect system from a building junction box. It also enters into a panel from the right or left (it pivots) and must mount in to an M-EH model number (Electrical Wiring Harness) or an M-EPS model number (Single Block).
∙ Sealtight base pathway power in-feed mounts into any receptacle position in the base pathway area.
∙ A heavy rubber sheathing shields conduit, allowing in-feed to be exposed.
Ceiling Power In-feed ∙ M-EPF3 - (168" Long) For use in
all Maxon Panel Systems. M-EPF3 connects to building junction box and poles. Can be used with desk height power applications for a 12' ceiling.
∙ Ceiling power in-feed connects to a prewired electrical harness in the base pathway, traverses through an adjacent panel, and terminates in the junction box at the top of the integrated power pole.
∙ Use integrated power pole model M-PFXC-78P. ∙ Most codes allow flex conduit to be exposed after installation. Verify
code requirements before ordering for exposed application.
Integrated Power/Communication Pole ∙ Integrated power pole accommodates
ceiling power in-feed and communication/data lines.
∙ Provide capacity for routing power in-feed and cables to the base pathway of a panel.
∙ Conduit of the in-feed cable serves as the division of electrical and communications cabling.
∙ Installs into 421⁄2-65"H or 15"H stacking 90°, “T”, and “X” connections.
∙ Integrated power pole includes trim kit. ∙ Single cavity with removable cover. ∙ Field-cut to desired length. ∙ Outside Dimension: 2" square. ∙ When using a ceiling power in-feed, consider that the in-feed must
connect into an electrical harness located in an adjacent panel. ∙ To power the prewired electrical system, from a ceiling power source, a
ceiling in-feed cable, M-EFP3 must be purchased separately. ∙ For applications requiring longer integrated power poles, a 156"H
model is available.
113
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
To Order:1. Determine which electrical system you
will use after consulting your electrician and computer support personnel: ∙ The four-circuit system
(4-Hot/2-Neutral/2-Ground)– 3 + 1 option– 2 + 2 option
2. Determine location, quantity, and circuit of duplexes.
3. Determine the appropriate choice and use of isolated, isolated/dedicated.
4. Specify appropriate power harnesses* and pass-thru cables.*
5. Determine the location, quantity, and type of power in-feed needed.
* Select Double Block Harness (M-EHXX), Single Block Harness (M-EPSXX), and Pass-Thru Harness (M-EPXX) with the last two digits corresponding with the panel width into which the component is to be positioned. The initial cable length can be stretched approximately 3" to transverse “T”, “X”, “L”, and extended straight connectors.
Electrical System OptionsThe four-circuit, eight-wire electrical system is widely specified and trusted by hundreds of thousands of end-users. This proven system delivers four circuits for every power in-feed in either a 3 + 1 or 2 + 2 configuration. The isolated/dedicated circuits are ideal for sensitive computing equipment, while the common circuits are suitable for faxes, copiers, task lights and other peripherals. Both the 3 + 1 and 2 + 2 systems use the same prewired components, making it easy to adjust as electrical needs change.
GRAYWHITEGRN/YLWGRN/BAREPINKBLUEREDBLACK
DUPLEX RECEPTACLECIRCUIT 1
12 GA10 GA12 GA12 GA12 GA12 GA12 GA12 GA
NEUTRAL - 2NEUTRAL - 1ISOLATEDGROUNDHOT - 4HOT - 3HOT - 2HOT - 1
CIRCUIT 2 CIRCUIT 3
CIRCUIT 4ISOLATED/DEDICATED
GRAYWHITEGRN/YLWGRN/BAREPINKBLUEREDBLACK
DUPLEX RECEPTACLECIRCUIT 1
12 GA10 GA12 GA12 GA12 GA12 GA12 GA12 GA
NEUTRAL - 2NEUTRAL - 1ISOLATEDGROUNDHOT - 4HOT - 3HOT - 2HOT - 1
CIRCUIT 2CIRCUIT 3ISOLATED
CIRCUIT 4ISOLATED
Four-circuit, 3 + 1 Receptacle Option
Four-circuit, 2 + 2 Receptacle Option
The 3 + 1 option is the electrical standard used on Maxon systems for many years in most installations. This wiring option provides three utility circuits plus an isolated/dedicated circuit for more sensitive equipment. Circuit 2 (one of the 3 common circuits sharing a neutral wire) cannot be used with single-phase building electrical supply.
The 2 + 2 option is a wiring option that provides two utility circuits and two isolated circuits for more extensive computer usage applications.
114
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Prefix System Receptacle UsageTwo 8-wire, 20 amp (15 amp Canadian electrical systems are offered
Electrical System Circuitry Receptacle Capacity
Four-circuit 4-Hot/2-Neutral/2-Ground
3 + 1Common Circuit-1 M-ED1
Common Circuit-2(1)
M-ED2
Common Circuit-3 M-ED3
Iso/Dedicated Circuit-4 M-ED4
2 + 2Common Circuit-1 M-ED1
Common Circuit-2 M-ED2
Isolated Circuit-3 M-ED3D
Isolated Circuit-4 M-ED4
(1) Circuit 2 (one of the 3 common circuits sharing a neutral wire) cannot be used with a single-phase building electrical supply.
Typical power usage by the most commonly specified office equipment.EQUIPMENT AMPS EQUIPMENT AMPS EQUIPMENT AMPS
ComputersPersonal Compute ............................. 3Notebook Computer.......................... 3Monitors13" Color Monitor ............................. 217" Color Monitor ............................. 321" Color Monitor ............................. 415" Plasma Monitor ....................... 0.520" Plasma Monitor .......................... 1
CopiersDesktop Copier ............................... 15Console Copier ............................... 20Copier/Duplicator ............................ 30PrintersInkJet .................................. less than 1Personal Laser or LED ........................ 8Workgroup Laser or LED .................. 15
Fax MachinesInkJet Fax ............................ less than 1Plain Paper Fax .................................. 8Task Lights30" T5 Fluorescent ...............0.12/bulb60" T5 Fluorescent ...............0.24/bulb
Source: Industry Analysis, Inc., Rochester, NY
Notes: ∙ Each Power In-feed has a capacity of a maximum of 60 amps. ∙ Each Circuit has a capacity of 15 amps.
Notes: ∙ Maxon Model Numbers are
printed on the UL labels, and components are color-coded to provide visual identification of the different components.
∙ Four-circuit components have black plastic parts.
15 amp Receptacle
Duplex Receptacles
115
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Electrical HarnessesElectrical power harnesses are used to distribute power in Prefix panels. Harness power blocks snap directly onto brackets in base pathway. Power blocks on electrical power harness and pass-thru harness accept duplex receptacles.
All electrical power harnesses and pass-thru harnesses will stretch 31⁄2", allowing them to span through "S" extended straight connections.
Note: "T" and 120° intersections require a minimum of one double block power harness and "X" intersections require a minimum of (2) double block power harnesses.
Electrical Double Block Harness ∙ Electrical Double Block Harnesses are used to distribute power
in panels. ∙ Prefix electrical can only be located at base pathway. ∙ Specify harness length to match panel width. ∙ 24" power harness accepts one receptacle on each side of the
harness, all other length power har nesses have power blocks to accept four duplex receptacles (two on each side of panel).
∙ Connectors at both ends of power harnesses allow power distri-bu tion in either direction.
∙ Harness power blocks snap directly onto brackets in base pathway.
Single Block Pass-Thru Harness ∙ Single Block Pass-Thru Harness with power block have capacity
to handle one duplex receptacle on each side of the panel when exposed.
∙ Specify harness length to match panel width or combined panel widths.
∙ Single Block Pass-Thru harnesses accept one duplex receptacle per panel side.
∙ Note: “T” intersections require a minimum of one power harness and “X” intersections requires a minimum of two power harnesses.
∙ All electrical Double Block Harnesses and Single Block Pass-Thru Harnesses with power block will stretch 31/2", allowing them to span “T”, “X”, “A” intersections, and “S” extended straight connections.
∙ Pass-Thrus are directional.
Electrical Pass-Thru Harness ∙ Specify harness length to match panel width or combined panel
widths. ∙ Electrical Pass-Thru Harnesses distribute power through any
panel(s) where receptacles are not required. Cable length cannot be stretched.
∙ Allows you to take power through a panel raceway. ∙ Duplex outlets cannot be used with M-EP Pass-Thru wiring. ∙ Pass-Thru runs from the receptacle location through the
connection to next panels receptacle location.
Single Block Pass-Thru Harness
Electrical Pass-Thru Harness
Electrical Double Block Harness
Requires minimum of one double block power
harness.
Use of a ceiling in-feed at this location requires an additional power harness.
Requires minimum of two double block power harnesses.
116
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Receptacles
Receptacle Color Recommended to Coordinate with Plastic Color
Paint Color Receptacle Plastic CodeBlack — MPBL .................................................................Black — E4Flint — MP02 .................................................................... Flint — E9Loft — MP7B .....................................................................Loft — EVGreige — MPT5 ............................................................Muslin — EUBrownstone — MP7D ...........................................Brownstone — EYMuslin — MPT3 ............................................................Muslin — EUGunmetal — MPR3 ...............................................Brownstone — EYChampagne — MPR5 ...................................................Muslin — EUPlatinum — MPPL .......................................................Titanium — TIDesigner White — PJW ................................. Designer White — DW
Duplex Receptacles ∙ Available with 3 integrated circuits 1, 2, or 3 (M-ED1, M-ED2,
M-ED3) and 1 isolated circuit 4 (M-ED4) or 2 integrated circuits 1 and 2 (M-ED1, M-ED2) and 2 isolated circuits 3 and 4 (M-ED3D, M-ED4).
∙ Each duplex outlet receptacle is rated at 15 amps. ∙ Each circuit has a 20 amp maximum capacity (depending upon
building wiring). ∙ Power-In Wiring (M-EPF2) plugs into Duplex Wiring Harness (M-EH
or M-EPS) in place of a Duplex Outlet Receptacle. ∙ Duplex Outlets may be added at any time by removing the outlet
cover plate and plugging the Duplex Outlet Receptacle into the Double or Single block harness.
∙ Isolated circuits are designated with an orange triangle. ∙ Duplex receptacles snap into power blocks of Double Block and
Single Block harnesses. ∙ Each receptacle is labeled to indicate which circuit it will be
connected to: 1, 2, 3, or 4. ∙ Duplexes support either 3+1 and 2+2 electrical in-feed.
Power/Data Modules — Clamp On Worksurface ∙ 6' Power cord. UL Listed. ∙ Includes adapters to allow use of commercially
available data terminals or blanks to fill unused openings. Many of the AMP, AT&T, Krone, Leviton and most commercial data terminals can be used.
∙ Color finish available: Loft. ∙ Fits on any worksurface with a 4′′ overhang.
Power/Data Modules — Clamp On Worksurface ∙ Must be installed at time of initial worksurface
installation if installing between a worksurface and panel.
∙ 6' Power cord. UL Listed. ∙ The USB hub allows simultaneous powering of
2 USB-A devices. The USB hub is a charger only, no ability to connect to a PC. The charging capacity is limited and may not charge all devices.
∙ Color finishes available: Storm (STRM) and Snow (SNW).
∙ Fits on any worksurface with a 4′′ overhang.
Power/Data Modules — Under Worksurface ∙ 6' Power cord. UL Listed. ∙ Color finishes available: Storm (STRM) and
Snow (SNW). ∙ Works with any top that has a 5′′ x 5′′ square
clearance.
Data Components
Data Faceplates ∙ Prefix not only provides space for large volumes of voice and data
cables, it also offers several means of mounti ng commercially available voice and data components.
∙ Commer cially available modular data faceplates can be mounted in vacant base receptacle openings.
∙ Due to panel depth, back-to-back data modules should not be used at the base on Prefix.
∙ Faceplates and Jacks available in black only.
Data Jacks ∙ AMP RJ45 CAT 5E Jack
∙ Black only ∙ Toolless
∙ AMP RJ45 CAT 6 Jack ∙ Black only ∙ Requires Tool
Duplex Receptacle
M-COMDOME2
M-PWRMOD2WC
M-PWRMOD3UWM
Voice/Data Receptacles
M-FP3RJ45 M-FP4RJ45
M-SIJRJ456S
117
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Base Pathway Receptacle Locations Circuit UsageStrategy 1Circuits to EquipmentAssign specific uses for each of the circuits: ∙ For example, in a
four-circuit system:Circuit 1 — Calculators,
fans, etc.Circuit 2 — Task lights
(could be wired to wall switch)
Circuit 3 — CRT or flat screen monitors
Circuit 4 — CPUs
Strategy 2Circuits to WorkstationsAssign specific workstations to each of the three avail-able circuits. Use circuit 4 for power-sensitive electronic equipment.
Placement of pedestals and lateral files may render some duplex locations inaccessible. Pedestal placement may also affect com-patibility with pull-up receptacles.
Knockout Dimension2.700"W x 1.377"H
Lay-in Cable Capacity ∙ The base pathway allows continuous voice and data lines to run
through and between panels without interruption. ∙ Lay-in is provided for environ ments where systems furniture or
cabling are subject to frequent change. ∙ Prefix base pathway accepts up to 77 voice/data cables (.25"
dia.) (6.27 sq. in.) at 60% fill. ∙ When electrical system shares base pathway, the cable capacity
in Prefix is reduced to 25 cables (2.03 sq. in.). ∙ Cable capacity of the Prefix integrated power pole is 3.3 sq. in.
for a total capacity of 34 cables of .25" diameter. ∙ Cables can enter/exit panel through underside of base path way
on frames.
Note: Cable quantities listed are at 60% fill ratio.
Prefix
77 cables
Prefix
25 cables
2"
2"Prefix
34 cables.25 dia
Model M-PFXD-78P
118
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Cable and Wire ManagementCable Management Tray ∙ Attaches under the worksurface to contain cables. ∙ Metal tray shelf is 4" deep. Can hold electrical power strip and/or surge protector. ∙ 24" and 36" lengths, use multiple units for larger worksurfaces. ∙ Attachment hardware included, specify paint color.
LightingTask Lighting ∙ Light Available in Black finish only. ∙ Mount under Overhead Storage Cabinet or Shelf. ∙ For Chicago Version with Fuse Plug, order FP Option. ∙ 6' Cord. ∙ Includes Florescent light bulb and hanger bars.
Universal Overhead Task Lighting ∙ Light Available in Black finish only. ∙ Mount under Overhead Storage Cabinet or Shelf. ∙ For Chicago Version with Fuse Plug, order FP Option. ∙ Excluded from GSA. ∙ Includes Florescent light bulb, mounting bars, 9' Cord and Four cord clips. ∙ Recessed task lights are black with a 9' long black cord that is attached to the right rear corner of the fixture. (Color does not
need to be specified.) ∙ Bulbs are included. ∙ RECOMMENDATION: Provide a separate circuit for task lights to ensure proper, long-term operation. ∙ Includes 4 cord retainer clips. ∙ Shorter width models can be used on wider overheads, shelves and hutches. ∙ All models are equipped with electronic ballast for longer bulb life and cooler operating temperature. ∙ On/Off switch provides individual control of tasklight within the workstation.
Cable Management Tray
119
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
See pages 111-118 for the specification guide.
Byrne Power-In Wiring
Description Model Wt. List
Power In-Feed through Side Receptacle (72") M-EPF2 0.5 348Power In-Feed through End or Power Pole (Ceiling-168") M-EPF3 0.5 348
Byrne Electrical Double Block HarnessIncludes ∙ Build-in Jumper.
Description Model W Wt. List
Single Block Duplex Harness 24W M-EH24 24" 2 235Double Block Duplex Harness 30W M-EH30 30" 2 261
M-EH36 36" 3 287M-EH42 42" 3 302M-EH48 48" 3 312M-EH60 60" 4 333M-EH72 72" 4 359
NOTE: Electrical harnesses are intended for use with Maxon systems furniture and are approved under GSA SIN 711-1. When purchased separately and used without Maxon systems furniture, those electrical harnesses are considered Open Market.
HOW TO SPECIFYSelect Model Number
M -
120
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
See pages 111-118 for the specification guide.
Byrne Electrical Pass-Thru Harness
Description Model Wt. List
Pass-Thru Harness M-EP24 1.2 164M-EP30 1.5 181M-EP36 1.7 189M-EP42 2 196M-EP48 2.3 219M-EP60 2.8 235M-EP72 4 262
Byrne Electrical Pass-Thru Harness
Description Model Wt. List
Single-Block Pass-Thru Harness M-EPS24 1.5 189M-EPS30 1.8 196M-EPS36 2 219M-EPS42 2.3 229M-EPS48 2.6 248M-EPS60 3.1 275M-EPS72 4 308
Byrne Electric Duplex Outlet Receptacle
Description Model Wt. Cubes List
Byrne Electric Duplex Outlet Circuit M-ED1 1 0.1 55M-ED2 1 0.1 55M-ED3 1 0.1 55
M-ED3D 1 0.1 55M-ED4 1 0.1 55
HOW TO SPECIFYSelect Model Number Select Plastic Color
See page 14
M - .
121
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
See pages 111-118 for the specification guide.
Telecommunication Receptacles
Description Model Wt. List
3-Port Faceplate (Shown) M-FP3RJ45 0.1 294-Port Faceplate M-FP4RJ45 0.1 29
Snap In Jack R45 Cat 5E (Shown) M-SIJRJ45 0.1 54Snap In Jack R45 Cat 6 M-SIJRJ456S 0.1 160
Byrne Chicago Outlet Box
Description Model Wt. List
Chicago Outlet Box - Base Raceway M-ECH1 0.1 133
Byrne New York Junction Box
Description Model Wt. List
Power In-Feed NY Junction Box M-EPFX 0.5 323
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
M - .
122
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
See pages 111-118 for the specification guide.
Prefix Integrated Power PoleIncludes ∙ Power Pole and trim.
List List
Description Model H Wt. Cubes P1 P2
Prefix Integrated Power Pole - 78"H(For 42.5"H panels and greater) M-PFXC-78P 78" 14 0.5 477 525
Prefix Integrated Power Pole -156"H M-PFXC-156P 156" 28 1.4 821 903
Electrical AccessoriesDescription Model Wt. Cubes List
2 Receptacles 1 USB Under Worksurface MT (Shown) M-PWRMOD2UWM 2.3 0.2 6303 Receptacles Under Worksurface Mt M-PWRMOD3UWM 2.3 0.2 437
Available in Storm (STRM) or Snow (SNW)
2 Receptacles 2 Data Accessory M-COMDOME2 2.5 0.2 458
Available in Loft
2 Receptacles 1 USB M-PWRMOD2WC 2.3 0.2 6303 Receptacles (Shown) M-PWRMOD3WC 2.3 0.2 437
Available in Storm (STRM) or Snow (SNW)
HOW TO SPECIFYSelect Model Number Select Plastic Color
See page 14
M - .
123
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Overhead storage cabinets can be
positioned vertically in 1" increments.
Locking clip feature secures storage
cabinets to panels.
Available in sliding door, flipper door and hinged door. Flipper door slides over top of cabinet.
Finish options include P1 and P2 paint.
Core removable locks allow lateral files, center drawers, pedestals, and overhead cabinets to be keyed alike.
Storage shelves can be positioned vertically in 1" increments.
Locking clipfeature secures storage
shelves to panels.
Backstop on assembled models keeps books, binders, and supplies from coming in contact with tile fabric.
Straight low profile end panels.
Center divider in sliding door models allows for either half to be locked.
15" design allows maximum storage while minimizing space.
Assembled Overhead Storage CabinetProduct DimensionsWidth: 24", 30", 36", 42", 48", 60", and 72"Inside Width: Flipper or 24"-36"W Hinged door — 3⁄8" less than width
42"-48"W Hinged or Sliding door — two compartments that are half of 3⁄8" less than width
Depth: 141⁄4 "Inside Depth: 127⁄8"Height: 15"Inside Height: 123⁄4"
RTA Overhead Storage CabinetProduct DimensionsWidth: 24", 30", 36", 42", 48", 60", and 72"Inside Width: Flipper or 24"-36"W Hinged door — 3⁄8" less than width
42"-48"W Hinged or Sliding door — two compartments that are half of 3⁄8" less than width
Depth: 12"Inside Depth: 115⁄8"Height: 15"Inside Height: 123⁄4"
Assembled ShelfProduct DimensionsWidth: 24", 30", 36", 42", 48", 60", and 72"Depth: 127⁄8"Height: 45⁄8"
RTA ShelfProduct DimensionsWidth: 24", 30", 36", 42", 48", 60", and 72"Depth: 111⁄2"Height: 55⁄8"
124
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
Specification Guidelines ∙ In a panel run, only two overhead storage cabinets or open
storage shelves are recommended per panel side. ∙ Overhead storage cabinets and open storage shelves can be
mounted on Prefix structural and stacking panels to a maximum height of 80"H.
∙ Base panel frames with stacking frames that have an overall height of 571/2" will not accept overhead storage cabinets if spanning between stacker and base panel.
∙ Immediate adjacent panels must be equal height to panels with overhead storage cabinets on them.
When overhead storage units are suspended from stacking frames, the following guidelines should be adhered to: ∙ Stacking panels can be added to any base panel up to 80"H. ∙ Stacking frames should be added to all the parent run panels,
and to each return-panel run. Stacking panels added to return panel must match the parent run configuration.
∙ A maximum of two overhead storage units should be suspended from each side of stacking frames on any given panel.
∙ No limitation to the number of units on structural frames when run is supported with return panels on each side of storage shelves or overhead storage cabinets.
∙ Assembled metal overhead cabinets can be mounted on a panel equal to or up to 18" narrower than cabinet.
∙ One side of overhead must be held on-module.
∙ RTA overhead and RTA shelf width must correspond with width of panel(s).
∙ It is possible to span two panels when combined panel width equals cabinet or shelf width.
Prefix65" + 15"
Prefix15"
291⁄2"
125
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Overheads, Shelves, and HutchesAssembled Overhead Storage Cabinet ∙ Overhead Cabinets have exposed back with
backsplash. ∙ Ball bearing Overhead Door slides. Door
recedes over top of Overhead Cabinet. ∙ Can be upmounted on base panel only. ∙ Steel cabinet with backstop. ∙ Available with sliding, hinged, or flipper
door(s). ∙ Sliding door overhead has (1) door. ∙ Easy-Assist flipper door optional —
requires minimal assistance in opening and closing.
∙ Easy-Assist flipper door not available on 60"W or 72"W cabinets — specify 2–30"W cabinets or 2–36"W cabinets.
∙ Self-engaging safety latch to secure cabinet to panel.
∙ Width can correspond with width of panel, or two panels joined with an inline connector kit.
∙ 60"W and 72"W flipper door cabinets have two doors with two independent locks.
∙ 24"-36"W hinged door cabinets have 1 lock and 2 arched pulls, 42"-48"W have 2 locks and 4 arched pulls.
∙ Accommodates recessed task lighting (specified separately).
∙ 15"H cabinets can also be mounted on a panel equal to or up to 18" narrower than cabinet.
∙ Sliding Door Overhead has a single door with built-in pull. ∙ Sliding, Hinged, and Flipper Door Overhead Weight Limits:
24"W ................59 lbs. 42"W ................ 105 lbs. 30"W ................74 lbs. 48"W ................ 121 lbs. 36"W ................90 lbs. 60"W ................ 152 lbs. ∙ Mounting an overhead on frames that have an overall height
of 571/2"H is not recommended. Slot modularity in relation to adjacent panels may be compromised.
Assembled Open Shelf ∙ Overhead Shelves have exposed back with
backsplash. ∙ Metal shelf with back stop. ∙ Locking clips (2) standard. ∙ Will accommodate recessed task lighting
(ordered separately). ∙ Weight Limits:
24"W ................61 lbs. 48"W ................ 124 lbs. 30"W ................77 lbs. 60"W ................ 155 lbs. 36"W ................93 lbs. 72"W ................ 183 lbs. 42"W ................108 lbs. ∙ Mounting an open shelf on Prefix frames cannot span base
panel frame and stack-on frame — slot modularity is not maintained.
Upmount Kits for Assembled Overhead Cabinets ∙ For use on base panels only. ∙ Consists of two upmount brackets, full back
panel, and required installation hardware. ∙ Allows mounting of an assembled overhead
cabinet up to 15" above height of panel. ∙ Specify upmount kits with 15"H, 35"H,
50"H, or 65"H Prefix panels. Upmount kits will not work with 421/2" panels.
∙ Brackets require a clearance of 61/2" below bottom of overhead cabinet.
∙ Width must correspond with width of panel frame or 2 panel frames joined directly inline.
∙ Full back panel adds 1/2" to depth of overhead case. ∙ Full back panel only used when upmounting cabinet. ∙ Cannot be used with RTA models.
Ready to Assemble (RTA) Flipper Door Overhead ∙ Overhead Cabinets have exposed back. ∙ Does not come preassembled. ∙ Can not be mounted off modular or
upmounted. ∙ Steel cabinet with open back. ∙ 60"W and 72"W cabinets have 2 doors
with independent locks. ∙ Accommodates recessed task lighting —
ordered separately. ∙ Random keying, for locking
specifications see page 129.
Ready to Assemble (RTA) Shelf ∙ Metal shelf with locking clips. ∙ Accommodates recessed task lighting —
ordered separately.
Sliding Door Overhead
Flipper Door Overhead
Hinged Door Overhead
Open Shelf
Upmount Kit for Overhead Cabinets
Ready to Assemble (RTA)Flipper Door Overhead
Ready to Assemble (RTA) Shelf
126
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
See pages 123-125 for the specification guide.All Actual Dimensions are listed on page 123.
Overhead Cabinets with Flipper DoorIncludes ∙ Overhead cabinets. ∙ Core removable locks. ∙ Two keys. ∙ Attaching brackets.
List List
Description Model H D W Wt. Cubes P1 P2
Flipper Painted Door - Panel Mount M-USOH1524F 15" 14.25" 24" 35 3.6 621 683M-USOH1530F 15" 14.25" 30" 38 4.4 645 710M-USOH1536F 15" 14.25" 36" 41 5.3 683 751M-USOH1542F 15" 14.25" 42" 46 6.1 733 806M-USOH1548F 15" 14.25" 48" 52 6.9 798 878M-USOH1560F 15" 14.25" 60" 62 8.6 1076 1184M-USOH1572F 15" 14.25" 72" 72 15.1 1234 1357
Flipper Easy Assist Painted Panel Mount M-USOH1524FE 15" 14.25" 24" 35 3.6 962 1058M-USOH1530FE 15" 14.25" 30" 38 4.4 1009 1110M-USOH1536FE 15" 14.25" 36" 41 5.3 1063 1169M-USOH1542FE 15" 14.25" 42" 46 6.1 1099 1209M-USOH1548FE 15" 14.25" 48" 52 6.9 1158 1274
Flipper Painted Door - Wall Mount M-UWMSOH1524F 15" 14.25" 24" 35 3.6 621 683M-UWMSOH1530F 15" 14.25" 30" 38 4.4 645 710M-UWMSOH1536F 15" 14.25" 36" 41 5.3 683 751M-UWMSOH1542F 15" 14.25" 42" 46 6.1 733 806M-UWMSOH1548F 15" 14.25" 48" 52 6.9 798 878M-UWMSOH1560F 15" 14.25" 60" 62 8.6 1076 1184
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
M - .
127
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
See pages 123-125 for the specification guide.All Actual Dimensions are listed on page 123.
Ready-to-Assemble Overhead Cabinet
Includes ∙ Overhead cabinets. ∙ Core removable locks. ∙ Two keys. ∙ Assembly hardware.
List List
Description Model H D W Wt. Cubes P1 P2
Panel Mount Ready-to-Assemble Overhead Cabinet with Flipper Door
M-USOC24R 15" 12" 24" 21 1.6 380 418M-USOC30R 15" 12" 30" 24 1.6 396 436M-USOC36R 15" 12" 36" 27 1.6 420 462M-USOC42R 15" 12" 42" 30 1.8 449 494M-USOC48R 15" 12" 48" 33 2.1 491 540M-USOC60R 15" 12" 60" 42 2.5 661 727M-USOC72R 15" 12" 72" 49 3 831 914
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
M - .
128
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
See pages 123-125 for the specification guide.All Actual Dimensions are listed on page 123.
Overhead Cabinets with Hinged DoorIncludes ∙ Overhead cabinets. ∙ Core removable locks. ∙ Two keys. ∙ Attaching brackets.
List List
Description Model H D W Wt. Cubes P1 P2
Panel Mount Hinged Painted Door M-USOH1524H 15" 14.25" 24" 35 3.6 1206 1327M-USOH1530H 15" 14.25" 30" 38 4.4 1253 1378M-USOH1536H 15" 14.25" 36" 41 5.3 1306 1437M-USOH1542H 15" 14.25" 42" 46 6.1 1342 1476M-USOH1548H 15" 14.25" 48" 52 6.9 1397 1537
Overhead Cabinets with Steel Sliding DoorIncludes ∙ Overhead cabinets. ∙ Attaching brackets. ∙ Two keys.
List List
Description Model H D W Wt. Cubes P1 P2
Panel Mount Steel Sliding Door M-USOH1524S 15" 14.25" 24" 35 3.6 749 824M-USOH1530S 15" 14.25" 30" 38 4.4 777 855M-USOH1536S 15" 14.25" 36" 41 5.3 813 894M-USOH1542S 15" 14.25" 42" 46 6.1 862 948M-USOH1548S 15" 14.25" 48" 52 6.9 921 1013M-USOH1560S 15" 14.25" 60" 62 8.6 1292 1421
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
M - .
129
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
See pages 123-125 for the specification guide.
Upmount Kits for OverheadsIncludes ∙ Two upmount brackets. ∙ Full back panel. ∙ Required installation hardware.
List List
Description Model W Wt. Cubes P1 P2
Up Mounted Overhead Kits M-USUM24 24" 7 0.3 266 293M-USUM30 30" 8 0.3 282 310M-USUM36 36" 10 0.4 301 331M-USUM42 42" 11 0.4 314 345M-USUM48 48" 12 0.5 325 358M-USUM60 60" 16 0.6 362 398
Overhead Cabinet Locks
Includes ∙ Each Lock Core Kit includes one core and core removal tool, two keys and instructions.
Description Model Wt. Cubes List
Lock Core Kit M-LC 1 0.1 40Master Key (1) M-MK 1 0.1 26
HOW TO SPECIFYSelect Model Number Select Paint Color or Lock Number
See page 14
M - .
130
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
See pages 123-125 for the specification guide.All Actual Dimensions are listed on page 123.
Overhead ShelvesIncludes ∙ Straight Shelf with Steel End Panels.
List List
Description Model H D W Wt. Cubes P1 P2
Universal Open Straight Shelf M-UOSS24 4.625" 12.875" 24" 11 1 314 345M-UOSS30 4.625" 12.875" 30" 13 1.2 325 358M-UOSS36 4.625" 12.875" 36" 14 1.3 332 365M-UOSS42 4.625" 12.875" 42" 17 1.5 337 371M-UOSS48 4.625" 12.875" 48" 19 1.6 342 376M-UOSS60 4.625" 12.875" 60" 23 2 362 398M-UOSS72 4.625" 12.875" 72" 23 3.6 445 490
Ready-to-Assemble (RTA) Overhead ShelfIncludes ∙ Straight Shelf with Steel End Panels.
List List
Description Model H D W Wt. Cubes P1 P2
Panel Mount RTA Overhead Shelf M-USSC24R 5.625" 11.37" 24" 10 1.9 190 209M-USSC30R 5.625" 11.37" 30" 11 1.9 198 218M-USSC36R 5.625" 11.37" 36" 12 1.9 214 235M-USSC42R 5.625" 11.37" 42" 13 2.1 237 261M-USSC48R 5.625" 11.37" 48" 14 2.4 260 286M-USSC60R 5.625" 11.37" 60" 16 3 291 320M-USSC72R 5.625" 11.37" 72" 18 3.5 320 352
Shelf OrganizerIncludes ∙ Vertically divides and aligns books, magazines and folders.
List List
Description Model Wt. Cubes P1 P2
Shelf Organizer M-PSO14 6 0.4 80 88
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
M - .
131
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
Accessories SpecificationsMaxon’s tool rail works in conjunction with a variety of accesso-ries. Modular accessories free up worksurface space and provide orderly storage that is well within reach. Units can be arranged and rearranged to respond to changing workflow. The work tools that attach to the tool rail are:
∙ Letter Tray ∙ File Pocket ∙ Binder Bin ∙ Tool Box
∙ Small Paper Clip Tray ∙ Personal Shelf ∙ Diagonal Tray ∙ Paper Clip
Coat hooks, marker boards and center drawers round out the organization offering.
Tool rail, shown above, is height-adjustable in 1" increments using slots in panels. Tool rail shown with two tool boxes, two letter trays and file pocket. File pocket and binder bins extend below a tool rail. Diagonal tray and contents extend above a tool rail.
Tool Rails and Work Tools ∙ The rails are designed for use on panels only. ∙ Accessories can be used only on the Universal Accessory Rail. ∙ Sturdy aluminum extrusion with steel support construction. ∙ Powder coated for durable finish. ∙ Cannot be used to support monitor arms. ∙ Suggested weight capacity not to exceed 80 lbs. ∙ Consideration needs to be given to height of tools and location
of worksurfaces. ∙ 5" high rail (widths coordinate with panels). ∙ Attachment via vertical reveals. ∙ Can be hung from wall track. Good solution for above copiers. ∙ Universal Accessory Rail is off-modular — can be used on a
panel of equal width or one size smaller. ∙ May span two panels of appropriate size, i.e., 60"W Tool Rail on
two 30"W panels.
Letter Tray ∙ Holds standard letter-size paper and
inter-office envelopes. ∙ Minimal horizontal intrusion.
File Pocket ∙ May be stacked by hanging back of File Pocket
onto front of another File Pocket to maximize space.
∙ Stores vertically for easy access to files.
Binder Bin ∙ Holds folders, binders, and manuals.
Tool Box ∙ Holds pencils and other writing utensils, large post-it
notes, and other desk top accessories.
Small Paper Clip Tray ∙ Holds paper clips and other small objects.
Personal Shelf ∙ Holds office supplies and personal
effects.
Diagonal Tray ∙ Diagonal trays are non-handed. ∙ Provides 3 fully divided slots for organizing
files. ∙ Keeps papers from “bowing” at bottom.
Paper Clip ∙ Binds project papers together. ∙ Mounts to tool rail or tool tile.
Coat Hook M-PMC6 ∙ Hangs directly into slotted Emerge or Prefix panel frame.
Use for coat or bag. ∙ Package of six. Available in black only.
Marker Board ∙ Panel Mount can be moved from space to
space as needed. ∙ This surface is a dry erase application. ∙ For use with dry marking pens. ∙ Hangs directly on Prefix panel frame. ∙ Steel tile with whiteboard paint. ∙ Surface is magnetic. ∙ Width must correspond with width of
panel.
Shelf Organizer ∙ Fits all Universal Overhead Cabinets and
Shelves. ∙ Not compatible with Overhead Cabinets with
Sliding Doors.
132
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
See page 118 for the specification guide.All Dimensions are Actual.
Task LightingIncludes ∙ Fluorescent light bulb. ∙ Hanger bars.
Description Wattage Model H D W Wt. Cubes List
Task Light 24W or greater 15 M-USL24 1.425" 6.875" 18.3" 6 0.4 284Task Light 30W or greater 20 M-USL30 1.425" 6.875" 24.3" 7 0.4 321Task Light 42W or greater 30 M-USL42 1.425" 6.875" 36.3" 9 0.4 357Task Light 54W or greater 40 M-USL54 1.425" 6.875" 48.3" 11 0.4 417
Task Light 24W or greater-Fuse Plug 15 M-USL24FP 1.425" 6.875" 18.3" 6 0.4 393Task Light 30W or greater-Fuse Plug 20 M-USL30FP 1.425" 6.875" 24.3" 7 0.4 432Task Light 42W or greater-Fuse Plug 30 M-USL42FP 1.425" 6.875" 36.3" 9 0.4 471Task Light 54W or greater-Fuse Plug 40 M-USL54FP 1.425" 6.875" 48.3" 11 0.4 510
List List
Description Model H D W Wt. Cubes P1 P2
Cord Cover (Manager) M-CCM10 10" 1.415" 1.125" 2 0.2 38 42Cord Cover (Manager) M-CCM15 15" 1.415" 1.125" 2 0.2 40 44Cord Cover (Manager) M-CCM20 20" 1.415" 1.125" 2 0.2 53 58
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
M - .
133
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
See page 118 for the specification guide.All Dimensions are Actual.
Universal Overhead Task LightingIncludes ∙ Fluorescent light bulb. ∙ 9' cord. ∙ 4 cord clips ∙ Mounting bars.
Description Model H D W Wt. Cubes List
Universal Overhead Task Light 24W M-USLO24 1.125" 3.7" 18.375" 5 0.4 236Universal Overhead Task Light 30W M-USLO30 1.125" 3.7" 22.875" 7 0.6 259Universal Overhead Task Light 42W M-USLO42 1.125" 3.7" 34.625" 10 0.9 293Universal Overhead Task Light 60W M-USLO60 1.125" 3.7" 46.5" 12 1.1 356
Universal Overhead Task Light 24W - Fuse Plug M-USLO24FP 1.125" 3.7" 18.375" 5 0.4 248Universal Overhead Task Light 30W - Fuse Plug M-USLO30FP 1.125" 3.7" 22.875" 7 0.6 281Universal Overhead Task Light 42W - Fuse Plug M-USLO42FP 1.125" 3.7" 34.625" 10 0.9 310Universal Overhead Task Light 60W - Fuse Plug M-USLO60FP 1.125" 3.7" 46.5" 12 1.1 383
HOW TO SPECIFYSelect Model Number
M -
EXCLUDED
EXCLUDED
134
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
See page 131 for the specification guide.All Dimensions are Actual.
Universal Accessory Panel Rail and AccessoriesList List
Description Model H D W Wt. Cubes P1 P2
Universal Accessory Rail M-ACCRAIL24 5" .5" 24" 5 0.2 228 251M-ACCRAIL30 5" .5" 30" 6 0.3 244 268M-ACCRAIL36 5" .5" 36" 7 0.3 257 283M-ACCRAIL42 5" .5" 42" 8 0.4 271 298M-ACCRAIL48 5" .5" 48" 9 0.4 280 308M-ACCRAIL60 5" .5" 60" 11 0.5 327 360
List List
Description Model H D W Wt. Cubes P1 P2
Personal Shelf (21") M-PS21 1.75" 7" 21" 3 0.05 161 177
List List
Description Model H D W Wt. Cubes P1 P2
Letter Tray M-LT 1.7" 9" 13" 0.05 0.05 156 172
List List
Description Model H D W Wt. Cubes P1 P2
Binder Bin M-SB 8.5" 5.2" 3" 0.08 0.08 156 172
List List
Description Model H D W Wt. Cubes P1 P2
Diagonal Tray - (Non-handed) (3) M-DT 8.5" 9.5" 4.5" 2 0.03 216 238
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
M - .
135
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
See page 131 for the specification guide.All Dimensions are Actual.
Universal Accessory Panel Rail and Accessories Continued...
List List
Description Model H D W Wt. Cubes P1 P2
File Pocket M-FP 8.9" 1.25" 12.25" 2 0.3 161 177
List List
Description Model H W Wt. Cubes P1 P2
Paper Clip M-CLIP2 1.9" 5" 1 0.2 161 177
List List
Description Model H W Wt. Cubes P1 P2
Small Paper Clip Tray M-SMTRAY 1.8" 6.8" 1 0.1 111 122
List List
Description Model H D W Wt. Cubes P1 P2
Tool Box M-TB 5.25" 1.5" 5" 1 0.2 125 138
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
M - .
136
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
See page 131 for the specification guide.All Dimensions are Nominal.
Panel Accessories
Description Model Wt. Cubes List
Coat Hook (6 pack) M-PMC6 0.3 0.3 46
Carpet Grippers
Description Model H W Wt. Cubes List
Carpet Grippers (12 pk) M-AGC12 6.5" 1.5" 0.2 0.3 49Carpet Grippers (4 pk) M-AGC4 6.5" 1.5" 0.1 0.3 29
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
M - .
137
Prefix® Panel SystemGSA SIN 711-1
|
M
eTL
STORAGE
VERSÉPREPARE
DeXTRINDEX
EM
ERGE
PREFIXREFERENCE
SM
ARTSPACESEATING
WORKSURFACES
ACCESSORIES
See page 131 for the specification guide.All Dimensions are Nominal.
Universal Panel Mounted WhiteboardIncludes ∙ Panel mounted whiteboard. ∙ Marker tray.
List List
Description Model H W Wt. Cubes P1 P2
Panel Mounted Whiteboard M-PMWB1324 13" 24" 6 1 424 466M-PMWB1330 13" 30" 7 1.3 463 509M-PMWB1336 13" 36" 9 1.5 485 534M-PMWB1342 13" 42" 10 1.7 496 546M-PMWB1348 13" 48" 12 2 507 558M-PMWB1360 13" 60" 15 2.4 524 576M-PMWB2624 26" 24" 9 1.9 507 558M-PMWB2630 26" 30" 11 2.3 527 580M-PMWB2636 26" 36" 13 2.8 535 589M-PMWB2642 26" 42" 15 3.2 546 601M-PMWB2648 26" 48" 18 3.6 557 613M-PMWB2660 26" 60" 23 4.5 572 629
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
M - .
138
Prefix® Panel System GSA SIN 711-1
|
SM
ARTS
PACE
VE
RSÉ
M
eTL
PREP
ARE
DeXT
RIN
DEX
SE
ATIN
G
EMER
GE
PREF
IXRE
FERE
NCE
W
ORKS
URFA
CES
ST
ORAG
E
ACCE
SSOR
IES
See page 131 for the specification guide.All Dimensions are Nominal. Pricing listed below for P1 Paint. P2 Paint finishes apply a 10% of LIST upcharge.
Universal Fabric Tackboard
Description Model H W Wt. Cubes Grade A Fabric
Grade B Fabric
Panel Mounted Fabric Tackboard M-PMTB1324 13" 24" 6 0.6 370 379M-PMTB1330 13" 30" 7 0.8 386 395M-PMTB1336 13" 36" 9 0.9 416 425M-PMTB1342 13" 42" 10 1.1 447 458M-PMTB1348 13" 48" 12 1.3 487 498M-PMTB1360 13" 60" 15 1.6 516 527M-PMTB2624 26" 24" 9 1.3 386 398M-PMTB2630 26" 30" 11 1.5 416 428M-PMTB2636 26" 36" 13 1.7 441 453M-PMTB2642 26" 42" 15 1.9 472 485M-PMTB2648 26" 48" 18 2.1 509 522M-PMTB2660 26" 60" 23 2.3 547 560
Wall Mounted Fabric Tackboard M-WMTB1324 13" 24" 6 0.6 370 379M-WMTB1330 13" 30" 7 0.8 386 395M-WMTB1336 13" 36" 9 0.9 416 425M-WMTB1342 13" 42" 10 1.1 447 458M-WMTB1348 13" 48" 12 1.3 487 498M-WMTB1360 13" 60" 15 1.6 516 527M-WMTB2624 26" 24" 9 1.3 386 398M-WMTB2630 26" 30" 11 1.5 416 428M-WMTB2636 26" 36" 13 1.7 441 453M-WMTB2642 26" 42" 15 1.9 472 485M-WMTB2648 26" 48" 18 2.1 509 522M-WMTB2660 26" 60" 23 2.3 547 560
HOW TO SPECIFYSelect Model Number Select Paint Color
See page 14
Select Fabric
See pages 15-16
M - . .