Environmental Emissions Monitor
TodayÕs cost-effective solution
SPECIFICATIONS
Sensors
Oxygen range 0% to 25%Oxygen resolution 0.1%Oxygen accuracy +/-0.3%
C O range 0 to 10,000 ppmC O resolution 1 ppmC O accuracy <100 ppm: +/- 5 ppm
>100 ppm: +/- 5%
N O range 0 to 1,000 ppmN O resolution +/-1 ppmN O accuracy <100 ppm: +/- 5 ppm
>100 ppm: +/- 5%
NO2 range 0 to 200 ppm NO2 resolution 1 ppm NO2 accuracy <20 ppm: +/- 2 ppm
>20 ppm: +/- 5%
SO2 range 0 to 2,000 ppm SO2 resolution 1 ppm SO2 accuracy <100 ppm: +/- 5 ppm
>100 ppm: +/-5%
H2S range 0 to 200 ppm H2S resolution 1 ppm H2S accuracy >40 ppm: +/- 5%
<40 ppm: +/- 2ppm
Instrument
Ambient operating temp. 0oC to 40oC; 32oF to 104oFBattery recharge to full 2 hoursCharger input voltage 115V or 230V; 50/60 Hz ACFuels Natural gas, light oil, propane,
heavy oil, coal, cokeDisplay Backlit LCD: 4 lines, 20 characters widePersonalised header 2 lines, 16 characters eachDimensions (mm/Ó) 280w x 120d x 112h; 11Ó x 4.8Ó x 4.5ÓW eight 1.3Kg; 3lbs (no case)
Probe
Construction Pistol-grip with stainless steel shaftInsertion length 300mm; 11.8ÓHose length 2500mm; 98ÓK-type thermocouple accuracy +/-0.3%; +/-1oCMax, temp. standard probe 800oCMax. temp. high temp. probe 1100oC
Integral printer
Type Impact with replaceable printer ribbon
Paper width 45mmCharacter width 16 characters
Draught/pressure measurement
Range +/- 150mb; +/- 60ÓWGResolution 0.01mb; 0.01ÓWGAccuracy +/- 0.5% fsd
These items are available as options
Wide Variety of
Applications
¥Power stations ¥Incinerators ¥ Landfill sites
¥ Furnaces ¥Industrial boilers ¥ Heattreatment ¥ Cement plant¥Ceramics kilns ¥ Paper
plant ¥ Crematoria
The Fleming Centre Fleming Way CrawleyW est Sussex RH10 2NN EnglandTel: +44 (0) 1293 528866 Fax: +44 (0) 1293 528811e-mail: [email protected] w w.telegangas.co.uk
TEMPEST 100 BROCHURE 2/1/01 10:23 am Page 1
Data download for easy system
integration
¥ Data download to PC via RS232 link, for further data analysis or inclusion in reports
¥ Compatible with most computers, with no extra software required.
Compact, portable, easy to use
¥ Integral printer provides immediate hard copy records ¥ Easy portability supported by 5-hour rechargeable battery,
or mains operation¥ Probe options: high temperature probe, 1Ð and 2Ðmetre
probes, probe extensions.
Emissions monitoring with automatic data
logging/print-out
¥ Enables unattended operation, with measurements stored and printed at userÐdefined time intervals
¥ Automatic measurements over extended periods forprocess monitoring.
Powerful portable versatility at economic cost
CO, 02 & NO measured (CO2 calculated) as standard - NO2, SO2 & H2S options
In todayÕs economic climate, many companies are balancing tough emissions standards withstringent budgetary limits. Addressing this requirement, Tempest 100 offers outstandinganalytical performance in one compact instrument at an affordable price.
Backed by the well established Tempest family, Tempest 100 offers an array ofgas sensors with integral printer and data logging, all packaged together inan ergonomic design.
Analytical Flexibility - wide range of gases and fuels
¥ Standard and optional gas ranges providing versatility and future upgradability
¥ Provision for six standard fuels, plus optional user-defined fuels
Temperature/efficiency and pressure measurement
¥ Inlet, stack and ambient temperature measurement with combustion efficiency calculation
¥ Gas pressure, flue draught and differential pressure measurements.
Operation stand-alone or with a fixed system
Tempest 100 can be standÐalone or complementary to a fixed monitoringsystem. It can validate readings of the fixed system and measure otherpoints around the plant. Furthermore it can provide backÐup when the fixedsystem is out of operation
TEMPEST 100 BROCHURE 2/1/01 10:23 am Page 3