How to Calibrate a Frac Pump and Data Van Pressure Transducer David Aakre Technologist

How To Calibrate a Frac Pump and Data Van Pressure Transducer

Embed Size (px)

Citation preview

Page 1: How To Calibrate a Frac Pump and Data Van Pressure Transducer

How to Calibrate a Frac Pump and Data Van Pressure Transducer

David Aakre Technologist

Page 2: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Pressure Transducer 0 to 15,000. Uses Calibration Pin A and D.

Page 3: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Transducer Calibration Switch on Pump Control Panel.

Page 4: How To Calibrate a Frac Pump and Data Van Pressure Transducer

From Remote Box Go to Pump Control.

Page 5: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Next Choose Hardware Setup

Page 6: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Choose Pump

Page 7: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Pump Sensors

Page 8: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Discharge Pressure

Page 9: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Calibration Screen

Page 10: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Calibration Steps for Pressure Transducer On Pump

SCREEN

MIN-SCALE READING 0 PSI SET

CALIBRATE MIN-SCALE 819 AVG COUNTS 21

FULL SCALE READING 15,000

CALIBRATE FULL SCALE 4095

ZERO CALIBRATION:

1. With very little pressure on pump, Press Calibrate Min-Scale Twice. The Scale counts should be around 819.

2. Press SET twice to save calibration.

FULL-SCALE CALIBRATION:

1. Hold calibration switch up at pump truck. Pressure on remote box should be 15,000 PSI. 2. Press Calibrate Full-Scale Twice. The Scale counts should be around 4095. 3. Release calibration switch at pump truck. 4. Press SET twice to save calibration.

Page 11: How To Calibrate a Frac Pump and Data Van Pressure Transducer

NOV Rolligon Pump Use Zero and Span to Calibrate Pressure Transducer

Page 12: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Data Van Well Head Pressure Transducer can be Calibrated this Way.

Page 13: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Data Van Well Head Pressure Transducers

• The Data Van usually has calibration switches for well head pressure transducers .

• Low counts are set in software which is zero pressure and is at 4 milliamps. 4ma= 0 psi

• High counts are set by holding switch up and hitting span or High counts button. 20 ma=15k

• Accufrac and Essex Software is set up using this method. Two point Calibration

Page 14: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Some Software Uses Pressure Transducer Slope for Calibration

• Slope =Max Pressure on Transducer / (4ma- 20ma)

• Slope = 15000psi/ 16 ma = 937.50• Slope= 100 psi transducer/ 16 ma= 6.25• Slope = 20k psi transducer/ 16 ma= 1250• I believe you got the point take max psi

reading on transducer and divide by 16.

Page 15: How To Calibrate a Frac Pump and Data Van Pressure Transducer

Software Using Slope for Pressure Transducer

Page 16: How To Calibrate a Frac Pump and Data Van Pressure Transducer

DAVID AAKRE TECHNOLOGIST

Make Shure you Calibrate all your pressure Transducers before you start the job. Safety is your first Priority.