The ID-6.2 system may be used at airports of all sizes and categories. The user may start with monitoring of a single system and then extend the scope of use to cover multiple systems. In the same way the system configuration may be changed. At the beginning the system may work with a single computer and subsequently more servers and workstations may be added.
Citation preview
ID-6.2AIRPORT CONTROL AND MONITORING SYSTEM
Control and monitoring system ID-6.2
All size airports control and monitoring
Software development since 1988
The modular concept
From single computer to redundant system
Based on object oriented SCADA software
Lifetime software warranty
Description The ID-6.2 complex control and monitoring system is designed for monitoring and control:
◦ airfield ground lighting (CCR, lamp control),◦ radio navigation devices,◦ radio communication devices,◦ energy facilities (switchboards, diesel generators, ups),◦ meteorological equipment,◦ fire and security signaling systems,◦ communication infrastructures( servers, workstations, routers).
ID-6.2
Interfaces Binary and analogue inputs and outputs of RTU/PLC units,
serial lines (standard communication interfaces RS232 and RS485),
network communication protocols (MODBUS, SNMP, OPC, SQL, OPC, ActiveX, DLL and DDE),
Simatic, Saia, Omron, Mitsubishi, Allen-Bradley, Adam, Tecomat, the Modbus protocol, open char/binary protocol etc.
Architecture Control server
Control workstation
Information workstation
Web based access to data◦ IE, Chrome, Firefox◦ Android, IOS
Security The ID-6.2 system security model is an object-oriented model with rights and authorizations delegated down to the level of particular points or objects. No matter what the type of client application is, each request for data must be in compliance with the data security settings.
All logins are registered in event database of ID-6.2 system, just as the changes in configuration, control settings and acknowledgement of alarm states/ messages.
Network management solution Errors and failures on systems can be prevented, if technical operators can react before the system failure occurs.
Information that indicate potential problems ◦ high CPU load,◦ high HDD usage,◦ system application freezing,◦ old (non-refresh) data,◦ communication status,◦ hardware status..
are obtained from servers and workstations via ◦ ICMP, SNMP, WMI protocols
Recommended use The ID-6.2 system may be installed at all types of airports
◦ from the smallest airports to the largest ones, ◦ from category I. to III., even at heliports.
Network Management Solutions
One HMI for many existing systems
AGL monitoring and control
Constant current regulators
Radiocommunication devices
Radionavigation devices
Energetics
Meteo
CCTV
Network monitoring
Network monitoring
One HMI for all systems
HMI based on user's requirement
Technical room
Control tower
Heliport
Control box
Thank you for your attention
Ing. Roman Šianský
RSI SOFT s.r.o.
Tel.: +420 606 762 933www.rsi-soft.cz e-mail: [email protected]