Citation preview
AMAXCooling
Solutions
™
The AMAX System
AMAX uses multiple heat exchange stages to maximize the energy savings potential of evaporative cooling while maintaining comfort across a broad range of ambient conditions.
AMAX offers Indirect Only Evaporative Cooling (IEC), Indirect/Direct (IDEC) and Hybrid DX configurations to meet all cooling requirements while saving up to 80% of the electric cost of comparable compressor based systems.
AMAX Applications• AMAX offers the greatest energy saving benefits in
extreme climate conditions- the hotter the ambient conditions the better the performance compared to DX.
• AMAX can provide 100% outdoor air and is ideal for casinos, hospitals, schools, restaurants or other installations that require large amounts of fresh conditioned air.
• AMAX Return on Investment is greatest when large amount of process cooling are required for extended periods – for example, in data centers, manufacturing facilities etc. Outdoor air is not required for these applications.
AMAX• Custom Engineering Solutions with
variable sizing and configuration to meet all requirements.
• Powered Economizers and Powered Pre-Coolers sized for quick retrofit to existing RTUs
• Integrated chilled or hot water coils for cost effective full HVAC solution.
Indirect/Direct Evaporative CoolersCommercial and Industrial Cooling Solutions
AMAX Features and Benefits
• Up to 125% adiabatic effectiveness• EER 40+ • Competitive pricing and low installed cost
for quick payback• Rugged, proven and designed for harsh
environmental conditions• Easy assembly and maintenance• Full engineering support
AMAX Retrofit Options
• Powered Economizers™ in IDEC or Indirect Only configuration significantly reduce DX cooling hours while providing cold conditioned fresh air.
• Powered Economizers can also be used to pre-cool condensing units for significant energy savings.
• Adding low cost Powered Economizers to RTUs results in Energy Savings, Rebates and Extended Life of the RTU.
How AMAX Works
AMAX Economizer Classic IDEC Rated at 115% adiabatic effectiveness
AMAX Economizer in fabrication
20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120
DRY BULB TEMPERATURE - °F
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
10 15 20 25 30
35
40
45
50
55
55
60
60
65
ENTH
ALPY
- BT
U P
ER P
OU
ND
OF
DR
Y AI
R
10
15
20
25
30
35
40
45
50
ENTH
ALPY
- BT
U PE
R PO
UND
OF DR
Y AI
RSA
TURA
TION
TEM
PERA
TURE
- °F
20
25
2530
3035
35 40
40 45
45 50
50 55
5560
60
65
65
70
70
75
75
80 WET BULB TEMPERATURE - °F
80
85
10% RELATIVE HUMIDITY
20%
30%
40%
50%
60%
70%
80%
90%
15.0
15.5
16.0
16.5 SPECIFIC VOLUM
E ft³/lb OF DRY AIR
17.0
17.5
18.0
HU
MID
ITY
RAT
IO -
GR
AIN
S O
F M
OIS
TUR
E PE
R P
OU
ND
OF
DR
Y AI
R
PSYCHROMETRIC CHART 5000 Feet above Sea LevelBAROMETRIC PRESSURE 24.906 inches of Mercury
Linric Company Psychrometric Chart, www.linric.com
.1
.2
.3
.4
.5
.6
.7
.8
.9
1
1.1
VAPO
R P
RES
SUR
E - I
NC
HES
OF
MER
CU
RY
-20
0
10
20
25
30
35
40
45
50
55
60
65
70
75
80
DEW
PO
INT
- °F
Ambient2nd Stage
Supply
AMAX IDEC Performance
Denver, Colorado
AMAX Psychrometric Chart for Denver, CO• Ambient = 93 DB/59 WB RH= 12.6%• 2nd Stage = 75.9/53.1 RH= 22.5%• Supply Temp = 53.9/53 RH= 95%
AMAX Supply Temperature and Cooling OutputASHRAE 1% Design Condition for Denver, Colorado
ASHRAE Design Conditions Ambient Unit AMAX Supply Dry Bulb
°FWet Bulb
°F Delta T EffectivenessDelta
TTemp
°FAMAX 1.0% 93 59 34 115% 39.1 54
AMAX Premium 1.0% 93 59 34 125% 42.5 51AMAX IEC Only 1.0% 93 59 34 75% 25.5 68
Single Stage Cooler 1.0% 93 59 34 85% 28.9 64
AMAX Calculated Cooling Output AMAX AMAX
Premium
Single Stage Cooler
AMAX Indirect Only
Unit size (cfm) 5,500 5,500 5,500 5,500
Unit Power Consumption (watts) 1,950 2,680 1,500 2,193
Unit Sensible Cooling (tons) 15 17 11 10
Unit EER (using Equivalent Tons) 87 72 69 54
AMAX Cooling Output and Energy ConsumptionEconomizer Retrofit Proposal – Monte Vista, CO
AMAX Sizing - Colorado ASHRAE Design Conditions Ambient AMAX AMAX AMAX
Dry Bulb °F Wet Bulb Delta T effectiveness Delta T Supply
1.0% 97 61 36 115% 41.4 55.6
AMAX Calculated Cooling Output in Monte Vista
Project Total Supply Air (CFM) 77,101
AMAX Total Power Consumption (watts) 7,500
Additional RTU Fan Power 7,710 (.1watt/cfm at .7" based on generic blower curve)
Total AMAX Power Consumption (watts) 15,210
AMAX Unit Sensible Cooling (tons) 226
AMAX Unit EER 178
AMAX Data Center Unit
AMAX Data Center Units- Portland, OR
AMAX Data Center UnitsRated at 15,000 cfm and 75% Effectiveness
AMAX Indirect Only Data Center Units
EasyStreet® Online Services, Inc. is Oregon’s largest independent Internet and IT services provider. Founded in 1995, EasyStreet is Oregon’s leading independent Managed Hosting and Co-location provider because it is reliable, responsive and responsible — to its customers, its community and the environment. http://easystreet.com/about/
Jack FlugVice President of Finance
Direct: 503-671-1894Email: [email protected]
For more information on the AMAX installation at EasyStreet Data Services please contact:
• “Energy-saving technologies such as Indirect Evaporative Cooling… reduce costs as well as carbon emissions while directing more power to customer cabinets.”
• “With this state-of-the-art design we have achieved an estimated 1.3 PUE (Power Use Effectiveness) where a traditional data is typically above a 2.0.”
• PUE is calculated by dividing total facility power consumption by server power use.
• PUE with standard CRAC was estimated at 1.6. PUE with AMAX is estimated at 1.3. Total AMAX cooling power use is .07.
• AMAX power consumption is estimated to cost $7,000 per month and save $30,000 per month compared with traditional CRAC units according to Rich Bader, President and CEO of EasyStreet.
AMAX Indirect Only Data Center UnitsEasyStreet Sustainablility Data Sheet
• Corey Trease – Carrier West– www.CarrierWest.com– 303.825.4328– [email protected]
• Mike Ballard – AMAX USA– www.AMAX.us.com– 720.641.5919– [email protected]
AMAXAdvanced Evaporative Cooling