42
Scott Hodgdon Senior Technical Marketing Engineer November 18, 2014 Catalyst Backbone and Instant Access Technologies 24.11.2014 © 2014 Cisco and/or its affiliates. All rights reserved.

Catalyst Backbone and Instant Access Technologies

Embed Size (px)

Citation preview

Page 1: Catalyst Backbone and Instant Access Technologies

Scott HodgdonSenior Technical Marketing EngineerNovember 18, 2014

Catalyst Backbone and Instant Access Technologies

24.11.2014 © 2014 Cisco and/or its affiliates. All rights reserved.

Page 2: Catalyst Backbone and Instant Access Technologies

New 6800 10GE Modules

New Instant Access Switches

Catalyst Instant Access Enhancements

Updated 6800 1GE Modules

Agenda

LISP Host Mobility (ASM)

Page 3: Catalyst Backbone and Instant Access Technologies

Catalyst 6807-XL How Sup2T will Operate

Supervisor Engine 2T:• Using the same XBAR Fabric ASIC

• Can use 1 to 4 channels (per Card)

• Increased per Channel bandwidth • New Clock Frequencies (up to 7.5Ghz)

• New Line Encodings (up to 64/66B)

• Applicable Only to Next-Gen Cards

• No changes to the MSFC5 or PFC4

• Local Channels for Uplinks @ 20Gbps

28 x 55G Channels

Support for up to 220G

per slot

Page 4: Catalyst Backbone and Instant Access Technologies

Introducing Updated C6800 1GE Cards

C6800-48P-TXC6800-48P-SFP

New ASICs and New C6807-XL Faceplate

1.5MB Buffers per 1GE Port

48 x 1GE Port

Density

Integrated DFC-4ALocal Forwarding

Fiber or Copper with Standard or XL Version

Strict Priority Queue on Transmit

Embedded Hardware RFID

Support in15.2(1)SY

Page 5: Catalyst Backbone and Instant Access Technologies

Updated C6800 1GE Cards

C6800-48P-TX:• 48 ports of RJ45• Single DFC4-A for 60Mpps

• 40Gbps Capacity per Slot

• Updated 1G Port ASICs• Fully integrated DFC-4A

• 1.5MB per Port buffering

• New Hardware RFID• Broadcasts PID and S/N

• New C6807-XL Faceplate

40Gper slot

Support in15.2(1)SY

Based on WS-X6848-TX

Page 6: Catalyst Backbone and Instant Access Technologies

Updated C6800 1GE Cards

C6807-XL.4SUP.VSS# sho mod swi 1 slot 7Switch Number: 1 Role: Virtual Switch Active---------------------- -----------------------------Mod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------ -----------7 48 DCEF-XL 48P 10/100/1000MB Ethernet C6800-48P-TX-XL SAL1736CC7W

Mod MAC addresses Hw Fw Sw Status--- ---------------------------------- ------ ------------ ------------ -------7 7c69.f69b.c8d8 to 7c69.f69b.c907 0.1 12.2(18r)S1 15.2(1)IC273 Ok

Mod Sub-Module Model Serial Hw Status ---- --------------------------- ------------------ ----------- ------- -------7 Distributed Forwarding Card WS-F6K-DFC4-AXL SAL1736CC7W 0.1 Ok

Mod Online Diag Status ---- -------------------7 Pass

C6807-XL.4SUP.VSS#

C6807-XL.4SUP.VSS# sho idprom swi 1 mod 7IDPROM for module, chassis 1, module 7

(FRU is 'DCEF-XL 48P 10/100/1000MB Ethernet')OEM String = 'Cisco Systems, Inc.'Product Number = 'C6800-48P-TX-XL'Serial Number = 'SAL1736CC7W'Manufacturing Assembly Number = '73-16637-01'Manufacturing Assembly Revision = '02'Hardware Revision = 0.1Current supplied (+) or consumed (-) = -7.00A

Page 7: Catalyst Backbone and Instant Access Technologies

Updated C6800 1GE Cards

C6800-48P-SFP:• 48 ports of SFP• Single DFC4-A for 60Mpps

• 40Gbps Capacity per Slot

• Updated 1G Port ASICs• Fully integrated DFC-4A

• 1.5MB per Port buffering

• New Hardware RFID• Broadcasts PID and S/N

• New C6807-XL Faceplate Based on WS-X6848-SFP

40Gper slot

Support in15.2(1)SY

Page 8: Catalyst Backbone and Instant Access Technologies

Updated C6800 1GE Cards

C6807-XL.4SUP.VSS# sho mod swi 2 slot 7 Switch Number: 2 Role: Virtual Switch Standby---------------------- -----------------------------Mod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------ -----------7 48 DCEF 48P 1GE SFP C6800-48P-SFP SAL1810N5E2

Mod MAC addresses Hw Fw Sw Status--- ---------------------------------- ------ ------------ ------------ -------7 b838.61d7.fca8 to b838.61d7.fcd7 0.1 12.2(18r)S1 15.2(1)IC273 Ok

Mod Sub-Module Model Serial Hw Status ---- --------------------------- ------------------ ----------- ------- -------7 Distributed Forwarding Card WS-F6K-DFC4-A SAL1810N5AL 2.0 Ok

Mod Online Diag Status ---- -------------------7 Pass

C6807-XL.4SUP.VSS#

C6807-XL.4SUP.VSS# sho idprom swi 2 mod 7IDPROM for module, chassis 2, module 7

(FRU is 'DCEF 48P 1GE SFP')OEM String = 'Cisco Systems, Inc.'Product Number = 'C6800-48P-SFP'Serial Number = 'SAL1810N5E2'Manufacturing Assembly Number = '73-16740-01'Manufacturing Assembly Revision = '01'Hardware Revision = 0.1Current supplied (+) or consumed (-) = -5.32A

Page 9: Catalyst Backbone and Instant Access Technologies

Updated 6800 1GE Modules

New 6800 10GE Modules

New Instant Access Switches

Catalyst Instant Access Enhancements

Agenda

LISP Host Mobility (ASM)

Page 10: Catalyst Backbone and Instant Access Technologies

6800 10GE Modules – 32 Ports

C6800-32P10G:• 32 ports of SFP / SFP+• Up to 8 Ports of QSFP*

• Dual DFC4-E for 120Mpps

• 160Gbps Capacity per Slot• Fully integrated DFC-4E (x2)

• Performance Mode for 1:1

• 250/500MB Per Port TX Buffers

• New Hardware RFID• Broadcasts PID and S/N

• New C6807-XL Faceplate

160G per slot

* with new CVR-4SFP-QSFP Adapter Cable

Based on WS-X6904-40G

Support in15.2(1)SY

Page 11: Catalyst Backbone and Instant Access Technologies

6800 10GE Modules – 32 Ports

FrontPanel

FIREASIC

Local Fabric ASIC

FIREASIC

DFC4

DFC4

40G

Fabric ASIC of Active Sup Fabric ASIC of Standby Sup

Backplane55G

Port ASIC Port ASIC

SFP 01-04

Port ASIC Port ASIC

Inband

Inband

Inband

Inband

FIREASIC

FIREASIC

PHY

SFP 05-08

PHY

SFP 09-12

PHY

SFP 13-16

PHY

SFP 17-20

PHY

SFP 21-24

PHY

SFP 25-28

PHY

SFP 29-32

PHY

55G 55G 55G 55G 55G 55G 55G

40G 40G40G

2x20G 2x20G

C6800-32P10G:• 8 x 4-SFP Port-Groups• DFC4-E supports 16 x SFP Ports

• New FIRE and Fabric ASICs• 55Gbps per Fabric Channel

• 40Gbps per FIRE ASIC • 2:1 Oversubscribed @ FIRE ASIC

• Performance Mode, per Port-Group

• 10GE or 40GE Mode, per Port-Group

• 1.25/2.5MB RX and 250/500MB TX

160G per slot

Page 12: Catalyst Backbone and Instant Access Technologies

6800 10GE Modules – 32 Ports

C6807-XL.4SUP.VSS# sho mod swi 2 slot 6Switch Number: 2 Role: Virtual Switch Standby---------------------- -----------------------------Mod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------ -----------6 40 DCEF2T 8 port 40GE / 32 port 10GE C6800-32P10G-XL SAL1829X3KC

Mod MAC addresses Hw Fw Sw Status--- ---------------------------------- ------ ------------ ------------ -------6 1005.caea.c804 to 1005.caea.c82b 0.103 15.1(58r)SYL 15.2(1)IC273 Ok

Mod Sub-Module Model Serial Hw Status ---- --------------------------- ------------------ ----------- ------- -------6 Distributed Forwarding Card C6800-DFC-XL SAL1829X3KC 0.103 Ok6 Distributed Forwarding Card C6800-DFC-XL SAL1829X46K 0.103 Ok

Mod Online Diag Status ---- -------------------6 Pass

C6807-XL.4SUP.VSS#

C6807-XL.4SUP.VSS# sho idprom swi 2 mod 6IDPROM for module, chassis 2, module 6

(FRU is 'DCEF2T 8 port 40GE / 32 port 10GE')OEM String = 'Cisco Systems, Inc.'Product Number = 'C6800-32P10G-XL'Serial Number = 'SAL1829X3KC'Manufacturing Assembly Number = '73-15693-02'Manufacturing Assembly Revision = '06'Hardware Revision = 0.103Current supplied (+) or consumed (-) = -14.00A

Page 13: Catalyst Backbone and Instant Access Technologies

6800 10GE Modules – 32 PortsInterface RepresentationC6807-XL.4SUP.VSS# sho int status swi 2 mod 6

Port Name Status Vlan Duplex Speed TypeTe2/6/1 connected routed full 10G 10Gbase-SRTe2/6/2 connected routed full 1000 1000BaseSXTe2/6/3 connected routed full 10G 10Gbase-SRTe2/6/4 connected routed full 1000 1000BaseSXTe2/6/5 disabled routed full 10G No ConnectorTe2/6/6 disabled routed full 10G No ConnectorTe2/6/7 connected routed a-full a-1000 10/100/1000BaseTTe2/6/8 connected routed full 10G 10Gbase-CU1MTe2/6/9 disabled routed full 10G No ConnectorTe2/6/10 disabled routed full 10G No Connector<snip>

C6807-XL.4SUP.VSS# sho int ten2/6/1 | i BW|mediaMTU 1500 bytes, BW 10000000 Kbit/sec, DLY 10 usec, Full-duplex, 10Gb/s, media type is 10Gbase-SR

C6807-XL.4SUP.VSS#

C6807-XL.4SUP.VSS# sho int ten2/6/2 | i BW|mediaMTU 1500 bytes, BW 1000000 Kbit/sec, DLY 10 usec, Full-duplex, 1000Mb/s, media type is 1000BaseSX

C6807-XL.4SUP.VSS#

NOTE: The TenGigabitEthernet interface name remains, even if 1G SFP transceiver is installed.

Use “show interface status” or “show interface” to determine the speed & type of transceiver.

Page 14: Catalyst Backbone and Instant Access Technologies

6800 10GE Modules – 32 PortsPort Groups, Operationa Mode and Buffers

C6807-XL.4SUP.VSS# sho hw-mod swi 2 slot 6 opSwitch 2 module 6 port group 1 is running in TenGigabitEthernet modeSwitch 2 module 6 port group 2 is running in TenGigabitEthernet modeSwitch 2 module 6 port group 3 is running in TenGigabitEthernet modeSwitch 2 module 6 port group 4 is running in TenGigabitEthernet modeC6807-XL.4SUP.VSS#

C6807-XL.4SUP.VSS# sho hw-mod swi 2 slot 6 oversubport-group oversubscription-mode1 enabled2 enabled3 enabled4 enabled

C6807-XL.4SUP.VSS# sho plat hard cap int | i buffer|2/6/Interface buffer sizes:Sw/Mod/Port Bytes: Tx buffer Rx buffer2/6/1 44015616 18595842/6/2 21528576 9344002/6/3 44015616 18595842/6/4 21528576 9344002/6/5 44015616 18595842/6/6 21528576 9344002/6/7 44015616 18595842/6/8 21528576 9344002/6/9 24576 N/A(Shared)2/6/10 21528576 9344002/6/11 24576 N/A(Shared)2/6/12 21528576 9344002/6/13 24576 N/A(Shared)2/6/14 21528576 9344002/6/15 24576 N/A(Shared)2/6/16 21528576 9344002/6/17 21528576 9344002/6/18 21528576 934400

<snip>

C6807-XL.4SUP.VSS# conf tEnter configuration commands, one per line. End with CNTL/Z.C6807-XL.4SUP.VSS(config)# no hw-mod swi 2 slot 6 oversub port-gr ?<1-4> Port group number of line card

C6807-XL.4SUP.VSS(config)# no hw-mod swi 2 slot 6 oversub port-gr 1WARNING: Switch to TRANSPARENT mode on switch 2 module 6 port-group 1.

C6807-XL.4SUP.VSS(config)#000749: Oct 2 04:20:45.322: %C6K_PLATFORM-SW1-6-VSS_NON_OVERSUBSCRIPTION_TEN_GIG: Ports 9, 11, 13, 15 switch 2, slot 6 disabled to prevent module bandwidth oversubscription.C6807-XL.4SUP.VSS(config)#endC6807-XL.4SUP.VSS#C6807-XL.4SUP.VSS# sho hw-mod swi 2 slot 6 oversubport-group oversubscription-mode1 disabled2 enabled3 enabled4 enabled

Page 15: Catalyst Backbone and Instant Access Technologies

80G per slot

6800 10GE Modules – 16 Ports

C6800-16P10G:• 16 ports of SFP / SFP+• Up to 4 Ports of QSFP*

• Single DFC4-E for 60Mpps

• 80Gbps Capacity per Slot• Fully integrated DFC-4E

• Performance Mode for 1:1

• 250/500MB Per Port TX Buffers

• New Hardware RFID• Broadcasts PID and S/N

• New C6807-XL Faceplate* with new CVR-4SFP-QSFP Adapter Cable

Based on WS-X6904-40G

Support in15.2(1)SY

Page 16: Catalyst Backbone and Instant Access Technologies

80G per slot

FrontPanel

FIREASIC

Local Fabric ASIC

DFC4

40G

Fabric ASIC of Active Sup Fabric ASIC of Standby Sup

Backplane55G

Port ASIC

SFP 01-04

Inband Inband

PHY

SFP 05-08

PHY

55G 55G 55G 55G 55G 55G 55G

FIREASIC

40G

Port ASIC

SFP 09-12

PHY

SFP 13-16

PHY

2x20G 2x20G

6800 10GE Modules – 16 Ports

C6800-16P10G:• 4 x 4-SFP Port-Groups• DFC4-E supports 16 x SFP Ports

• New FIRE and Fabric ASICs• 55Gbps per Fabric Channel

• 40Gbps per FIRE ASIC • 2:1 Oversubscribed @ FIRE ASIC

• Performance Mode, per Port-Group

• 10GE or 40GE Mode, per Port-Group

• 1.25/2.5MB RX and 250/500MB TX

Page 17: Catalyst Backbone and Instant Access Technologies

6800 10GE Modules – 16 Ports

C6807-XL.4SUP.VSS# sho mod swi 1 slot 6Switch Number: 1 Role: Virtual Switch Active---------------------- -----------------------------Mod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------ -----------6 20 DCEF2T 4 port 40GE / 16 port 10GE C6800-16P10G-XL SAL1815Q9ZK

Mod MAC addresses Hw Fw Sw Status--- ---------------------------------- ------ ------------ ------------ -------6 7426.acea.8520 to 7426.acea.8533 0.101 15.1(54r)SYL 15.2(1)IC273 Ok

Mod Sub-Module Model Serial Hw Status ---- --------------------------- ------------------ ----------- ------- -------6 Distributed Forwarding Card C6800-DFC-XL SAL1815Q9ZK 0.101 Ok

Mod Online Diag Status ---- -------------------6 Pass

C6807-XL.4SUP.VSS#

C6807-XL.4SUP.VSS# sho idprom swi 1 mod 6IDPROM for module, chassis 1, module 6

(FRU is 'DCEF2T 4 port 40GE / 16 port 10GE')OEM String = 'Cisco Systems, Inc.'Product Number = 'C6800-16P10G-XL'Serial Number = 'SAL1815Q9ZK'Manufacturing Assembly Number = '73-15856-02'Manufacturing Assembly Revision = '01'Hardware Revision = 0.101Current supplied (+) or consumed (-) = -7.24A

Page 18: Catalyst Backbone and Instant Access Technologies

80G per slot

6800 10GE Modules – 8 Ports

C6800-8P-10G:• 8 ports of SFP / SFP+• Up to 2 Ports of QSFP*

• Single DFC4-E for 60Mpps

• 80Gbps Capacity per Slot• Fully integrated DFC-4E

• 500MB Per Port TX Buffers

• New Hardware RFID• Broadcasts PID and S/N

• New C6807-XL Faceplate

* with new CVR-4SFP-QSFP Adapter Cable

Based on WS-X6904-40G

Support in15.2(1)SY

Page 19: Catalyst Backbone and Instant Access Technologies

FrontPanel

FIREASIC

Local Fabric ASIC

DFC4

40G

Fabric ASIC of Active Sup Fabric ASIC of Standby Sup

Backplane55G

Port ASIC

SFP 01-04

Inband Inband

PHY

55G 55G 55G 55G 55G 55G 55G

FIREASIC

40G

Port ASIC

SFP 05-08

PHY

2x20G 2x20G

80G per slot

6800 10GE Modules – 8 Ports

C6800-8P10G:• 2 x 4-SFP Port-Groups• DFC4-E supports 8 x SFP Ports

• New FIRE and Fabric ASICs• 55Gbps per Fabric Channel

• 40Gbps per FIRE ASIC

• 1:1 Line-Rate @ 80G

• No Oversubscribe / Performance Mode

• 10GE or 40GE Mode, per Port-Group

• 2.5MB RX and 500MB TX

Page 20: Catalyst Backbone and Instant Access Technologies

6800 10GE Modules – 8 Ports

C6807-XL.4SUP.VSS# sho mod swi 2 slot 6Switch Number: 2 Role: Virtual Switch Standby---------------------- -----------------------------Mod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------ -----------6 10 DCEF2T 2 port 40GE / 8 port 10GE C6800-8P10G-XL SAL1816QGVT

Mod MAC addresses Hw Fw Sw Status--- ---------------------------------- ------ ------------ ------------ -------6 7426.acea.8ac0 to 7426.acea.8ac9 0.101 15.1(54r)SYL 15.2(1)IC273 Ok

Mod Sub-Module Model Serial Hw Status ---- --------------------------- ------------------ ----------- ------- -------6 Distributed Forwarding Card C6800-DFC-XL SAL1816QGVT 0.101 Ok

Mod Online Diag Status ---- -------------------6 Pass

C6807-XL.4SUP.VSS#

C6807-XL.4SUP.VSS# sho idprom swi 2 mod 6 IDPROM for module, chassis 2, module 6

(FRU is 'DCEF2T 2 port 40GE / 8 port 10GE')OEM String = 'Cisco Systems, Inc.'Product Number = 'C6800-8P10G-XL'Serial Number = 'SAL1816QGVT'Manufacturing Assembly Number = '73-15858-02'Manufacturing Assembly Revision = '01'Hardware Revision = 0.101Current supplied (+) or consumed (-) = -7.24A

Page 21: Catalyst Backbone and Instant Access Technologies

6807-XLOptimized for 10G/40G/100G

160G/slot6900

CARD80G/slot

New 10/40G

SPEED

6500-E

92G/slot6900

SPEEDCARD80G/slot

New 10/40G

Optimized for 1G/10G/40G

New High Density Multi-Rate Line CardsSupported in both C6500-E and C6807-XL

Page 22: Catalyst Backbone and Instant Access Technologies

New 6800 10GE Modules

Updated 6800 1GE Modules

New Instant Access Switches

Catalyst Instant Access Enhancements

Agenda

LISP Host Mobility (ASM)

Page 23: Catalyst Backbone and Instant Access Technologies

New IA Client w/ Redundant PSU• C6800IA-48FPDR• Available @ 15.1(2)SY3• Same design as 48FPD

Two Removable Power Supply Units Each PSU provides 1025W AC

Total Available Power Is Still 740W

1:1 Redundant (No Combined Mode)

Instant Access ClientC6800-IA-48X – Redundant Power

Built-In Stack Module (Rear)

System and Status LEDs

2 x SFP+ Uplink Ports

48 x RJ45User PortsRJ45 Console

and Mgmt Ports*

(Rear) Built-In Stack Module

1025W AC Redundant PSU

1025W ACRemovable PSUPower Cord

Management

PSU StatusLEDs PSU

Thumb Lock

AC Input

Page 24: Catalyst Backbone and Instant Access Technologies

New Compact IA Client• C3560CX-12PD-S• Available @ 15.2(1)SY

12 Ports of 1GE RJ45 with POE+ 15W or 30W per port 240W POE Budget

2 Port of 10GE SFP+ Uplinks

2 Ports of 1G RJ45 Uplinks

Compact IA Setup• A Local CLI for FEX Mode• FEX Mode Dynamic Detect• Does Not Support Stacking

Instant Access ClientC3560-CX – FEX Mode

System and Status LEDs

2 x SFP+Uplink PortsUSB Type B

Console Port

12 x RJ45POE Ports

RJ45 Serial Console Port

USB Type A Disk

Drive

2 x RJ45Uplink Ports

More SKUs Coming Soon

Page 25: Catalyst Backbone and Instant Access Technologies

New 6800 10GE Modules

Updated 6800 1GE Modules

New Instant Access Switches

Catalyst Instant Access Enhancements

Agenda

LISP Host Mobility (ASM)

Page 26: Catalyst Backbone and Instant Access Technologies

Cisco Catalyst Instant Access

STANDALONE VSS

LACP orPAGP

LACP orPAGP

Access Switch Access Switch

VSL

INSTANT ACCESS

SDPSRPSCP

Instant AccessClient

Instant AccessClient

VSL

Access Switch Access Switch

LACP orPAGP

Page 27: Catalyst Backbone and Instant Access Technologies

Connect Compact SwitchSTACKING POE+

Instant Access Client CapabilitiesDifferences From Nexus FEX

Fabric Link

Spanning-tree bpduguard

Disable

Page 28: Catalyst Backbone and Instant Access Technologies

Catalyst 6880-X

Catalyst 6800IA

Catalyst 6500-E Sup2T

Instant Access Platform Support New Line Cards and Client Switch

6800IA-48FPD

6800IA-48FPDR

WS-C3560CX-12PD-S

Sup2TCatalyst 6807-XL

WS-X6904-40GC6800-

32P10G/XLC6800-

16P10G/XLC6800-8P10G/XL

6800IA-48TDC6800-32P10G/XL

C6800-16P10G/XL

C6800-8P10G/XL

WS-X6904-40G

Page 29: Catalyst Backbone and Instant Access Technologies

15.1(2)SY + 15.2(1)SY +

53

12FEX 102 FEX 103 FEX 104 FEX 105 FEX 106 FEX 107 FEX 108 FEX 109 FEX 110 FEX 111FEX 101

FEX 102 FEX 103 FEX 104 FEX 105 FEX 106 FEX 139 FEX 140 FEX 141 FEX 142FEX 101- - - - - -

42

Boosting Instant Access Scale

STACKING

FABRIC LINK

Page 30: Catalyst Backbone and Instant Access Technologies

Boosting Instant Access Scale

Switch#sh module fex 101Switch Number: 101 Role: FEX---------------------- ------------------------------------------Mod Ports Card Type Model Serial No.--- ----- -------------------------------------- ------------------1 48 C6800IA 48GE C6800IA-48TD FOC1737W0PF2 48 C6800IA 48GE POE C6800IA-48FPD FOC1736Z0363 48 C6800IA 48GE C6800IA-48TD FOC1737W0NP4 48 C6800IA 48GE POE C6800IA-48FPD FOC1741S58N5 48 C6800IA 48GE POE C6800IA-48FPD FOC1736Z03L

Switch#sh fex 101 detail FEX: 101 Description: FEX0101 state: onlineFEX version: 15.2(3.2.3)EExtender Model: C6800IA-48FPD, Extender Serial: FOC1736Z036FCP ready: yesImage Version Check: enforcedFabric Portchannel Ports: 8Fabric port for control traffic: Te1/2/5 Fabric interface state:Po10 - Interface Up.

Te1/2/5 - Interface Up. state: bound Te1/2/6 - Interface Up. state: bound Te1/2/7 - Interface Up. state: bound Te1/2/8 - Interface Up. state: bound Te2/2/5 - Interface Up. state: bound Te2/2/6 - Interface Up. state: bound Te2/2/7 - Interface Up. state: bound Te2/2/8 - Interface Up. state: bound

Switch#sh etherchannel 10 summary Flags: D - down P - bundled in port-channel!Number of channel-groups in use: 3Number of aggregators: 3Group Port-channel Protocol Ports------+-------------+---------------------------------10 Po10(SU) - Te1/2/5(P) Te1/2/6(P) Te1/2/7(P)

Te1/2/8(P) Te2/2/5(P) Te2/2/6(P) Te2/2/7(P) Te2/2/8(P)

Last applied Hash Distribution Algorithm: Adaptive

Page 31: Catalyst Backbone and Instant Access Technologies

Catalyst Instant Access Phase 2 Scalability

SUP2T * 15(2)1SY 15(2)1SY1Maximum Client Node User Ports 1200 1500

Maximum FEX ID’s 25 32

Maximum Client Switches 25 32

Maximum Clients in Stack 5 5Maximum User Ports in Stack 240 240

6880X SwitchMaximum Client Node User Ports 2000Maximum FEX ID’s 42Maximum Client Switches 42Maximum Clients in Stack 5Maximum User Ports in Stack 240

Switch#sh fex system platform usageFEX id usage details

Fex-ids inuse: 101Fex-ids online: 101Total Used Free----- ---- ----42 1 41

FEX slot usage detailsFEX-id Switch-id Vslot Pslot Status------ -------- ----- ----- ------

101 3 50 3 In-use 101 3 51 2 In-use 101 3 52 5 In-use 101 3 53 4 In-use 101 3 54 1 In-use

Total Used Reserved Free----- ---- -------- ----42 5 0 37

FEX ports usage detailsFEX-id Switch-id Ports------ -------- -----

101 3 240Total Used Free----- ---- ----2016 240 1776

Stack members usage detailsFEX-id Switch-id Used Free------ -------- ---- ----

101 3 5 0

VNTAG MGR Usage-----------------------Max unicast VIFs available 2048Total unicast VIFs used 432Max non-mdest VIFs available 1019Total non-mdest VIFs used 1Max mdest VIFs available 16380Total mdest VIFs used 0

* Maximum Supported by TAC

Page 32: Catalyst Backbone and Instant Access Technologies

Instant Access with C3560-CX

• 15.2(1)SY or above on Cat6K

• 2 x 10G uplink models:

• 3560CX-12PD-S• 3560CX-8XPD-S (1H,CY15)

• Compact IA Scale: 42 clients (FEXs)504 ports with 3560CX-12PD-S336 ports with 3560CX-8XPD-S

• Standalone Mode (default)

• Instant Access Mode (CLI, Auto Detect)

• New image for 3560-CX bundled with Sup2T (~20MB increase in image size)

• Both 3560-CX and 6800IA can be connected to the same Cat6K parent

Access

Aggregation Catalyst

6500/6800 VS

C6800IA C3650-CX IA C3650-CX IA

C3560CX# fex-mode enable System will reload after mode conversion.Do you want to continue? [no] yes

FEX-130# sho fexFEX FEX FEX FEXNumber Description State Model Serial-------------------------------------------------------------------------------------------------------------130 Local FEX online WS-C3560CX-12PD-S FHH1810P07A

C6K-VSS# sho fexFEX FEX FEX FEXNumber Description State Model Serial-------------------------------------------------------------------------------------------------------------110 FEX0110 online C6800IA-48TD FOC1725X2AG130 FEX0130 online WS-C3560CX-12PD-S FHH1810P07A

3K-CX

6K

Page 33: Catalyst Backbone and Instant Access Technologies

New 6800 10GE Modules

Updated 6800 1GE Modules

New Instant Access Switches

Catalyst Instant Access Enhancements

Agenda

LISP Host Mobility (ASM)

Page 34: Catalyst Backbone and Instant Access Technologies

LISP Host Mobility Three Simple Steps for Host Mobility…

1. Detection of Mobility Eventa) For any host, without agents on the host or protocols

2. Registration with the Mapping System

3. Notifications to other xTRs / PITRsa) Update routing tables at old sites (map-notify)

b) Update LISP Map-Caches (Solicit Map Request)

Page 35: Catalyst Backbone and Instant Access Technologies

LISP Across Subnet Mode (ASM) Topology

Enterprise Core

RLOC 12.0.0.1

RLOC 12.1.1.1

RLOC 12.2.2.1

xTR1

xTR1xTR1

MS/MR:1.1.1.1

10.17.1.0/2410.18.1.0/24

LISP SITE: BUILDING 1

LISP SITE: BUILDING 2

10.10.10.0/24

LISP SITE:DC

MS/MR

router lispdatabase-mapping 10.10.10.0/24 12.0.0.1 priority 1 weight 100!ipv4 itripv4 etripv4 itr map-resolver 1.1.1.1ipv4 etr map-server 1.1.1.1 key abcdexit

router lisplocator-set ASM12.1.1.1 priority 1 weight 50

!database-mapping 10.17.0.0/16 12.1.1.1 priority 1 weight 50dynamic-eid MOBILE_SUBNETdatabase-mapping 10.17.1.0/24 locator-set ASM

!ipv4 itripv4 etripv4 itr map-resolver 1.1.1.1ipv4 etr map-server 1.1.1.1 key abcd

!interface Vlan20ip address 10.17.1.1 255.255.255.0ip verify unicast source reachable-via rx allow-self-pinglisp mobility MOBILE_SUBNETplatform lisp-enablemac-address 0000.0e1d.010c

end

router lisplocator-set ASM12.2.2.1 priority 1 weight 50

!database-mapping 10.18.0.0/16 12.2.2.1 priority 1 weight 50dynamic-eid MOBILE_SUBNETdatabase-mapping 10.17.1.0/24 locator-set ASM !ipv4 itripv4 etripv4 itr map-resolver 1.1.1.1ipv4 etr map-server 1.1.1.1 key abcd

!interface Vlan30ip address 10.18.1.1 255.255.255.0ip verify unicast source reachable-via rx allow-self-pinglisp mobility MOBILE_SUBNETplatform lisp-enablemac-address 0000.0e1d.010c

end

Page 36: Catalyst Backbone and Instant Access Technologies

Enterprise Core

RLOC 12.0.0.1

RLOC 12.1.1.1

RLOC 12.2.2.1

xTR1

xTR1xTR1

MS/MR:1.1.1.1

10.17.1.0/2410.18.1.0/24

10.10.10.0/24

LISP SITE:DC

LISP Across Subnet Mode(ASM)MS/MR Configuration

MS/MR

MS:1.1.1.1MR:1.1.1.100

interface loopback0description *** Map-Server/Map-Resolver ***ip address 1.1.1.1 255.255.255.255!router lisp!ipv4 map-serveripv4 map-resolver

!site DCauthentication-key abcdeid-prefix 10.10.10.0/24

!site BLDG2authentication-key abcdeid-prefix 10.18.0.0/16 accept-more-specifics

!site BLDG1authentication-key abcdeid-prefix 10.17.0.0/16 accept-more-specifics

end

LISP SITE: BUILDING 1

LISP SITE: BUILDING 2

Page 37: Catalyst Backbone and Instant Access Technologies

Enterprise Core

RLOC 12.0.0.1

RLOC 12.1.1.1

RLOC 12.2.2.1

xTR1

xTR1xTR1

MS/MR:1.1.1.1

10.17.1.0/2410.18.1.0/24

LISP SITE: BUILDING 1

LISP SITE: BUILDING 2

10.10.10.0/24

LISP SITE:DC

LISP Across Subnet Mode(ASM)Routing Table and Map Cache Content Prior to Migration

Routing Table:10.17.1.0/24 – Local10.17.1.10/32 - LocalMapping Database:10.17.1.0/16 – RLOC 12.1.1.110.18.0.0/16 - RLOC 12.2.2.110.17.1.10/32 – RLOC 12.1.1.1

Map Cache @ ITR10.17.1.0/16 – RLOC 12.1.1.110.18.0.0/16 – RLOC 12.2.2.110.17.1.10/32 – RLOC 12.1.1.1

10.17.1.10

Routing Table:10.18.1.0/24 – Local10.17.1.0/24 – LISP010.17.1.10/32 – LISP0Mapping Database:10.17.1.0/16 – RLOC 12.1.1.110.18.0.0/16 – RLOC 12.2.2.110.17.1.10/32 – RLOC 12.1.1.1

MS/MR

Page 38: Catalyst Backbone and Instant Access Technologies

Enterprise Core

RLOC 12.0.0.1

RLOC 12.1.1.1

RLOC 12.2.2.1

xTR1

xTR1xTR1

10.17.1.0/2410.18.1.0/24

10.10.10.0/24

LISP SITE:DC

LISP Across Subnet Mode(ASM)Host Workload Mobility

MS/MR

1

Routing Table10.17.1.0/24 - LISP010.18.0.0/24 – Local

2

10.17.1.10/32 - Local

Mapping Database10.17.0.0/16 - 12.1.1.110.18.0.0/16 – 12.2.2.1

10.17.1.10/32 – 12.2.2.1

34

Routing Table10.17.1.0/24 - Local

5

10.17.1.10/32 – LISP010.17.1.10/32 – Local

10.17.1.10/32 – 12.1.1.1

10.17.1.10 10.17.1.10

Map Register10.17.1.10/32RLOC: 12.1.1.1

LISP SITE: BUILDING 1

LISP SITE: BUILDING 2

MS/MR1.1.1.1

Page 39: Catalyst Backbone and Instant Access Technologies

Enterprise Core

RLOC 12.0.0.1

RLOC 12.1.1.1

RLOC 12.2.2.1

xTR1

xTR1xTR1

MS/MR:1.1.1.1

10.17.1.0/2410.18.1.0/24

10.10.10.0/24

LISP SITE:DC

LISP Across Subnet Mode(ASM)Refreshing Map-Caches

MS/MR

10.17.1.10

Mapping Database10.17.0.0/16 - 12.1.1.110.18.0.0/16 – 12.2.2.110.17.1.10/32 – 12.1.1.110.17.1.10/32 – 12.2.2.1

1. ITRs, PITRs with cached mappings continue to send traffic to the old locators until updated

1

2. Old Building xTR sends Solicit Map Request (SMR) messages to any encapsulators sending traffic to “it” for a dynamic EID that is not discovered (data-triggered SMR)

2

map-request

3. SMR causes ITR to initiate a new map-request/map-reply process

map-request

4. Map-Reply updates map-cache with new location

5. Traffic now flows to the SAME HOST at its NEW location34

LISP SITE: BUILDING 1

LISP SITE: BUILDING 2

Page 40: Catalyst Backbone and Instant Access Technologies

LISP Host Mobility Requirements for ASM

xTR should be first Layer-3 hop (IP Gateway)

Proxy-ARP should be enabled on xTR’s gateway interface

xTR’s gateway MAC address should be same on all roaming sites

All roaming sites xTRs should register with the same set of map-servers

Mobility hosts should not be “silent” after they move

Requires multicast on xTRs (only if site has multiple xTRs)

Page 41: Catalyst Backbone and Instant Access Technologies

LISP Host Mobility Show/Debug

Show commands show lisp dynamic-eid summary show ip lisp database show ip route <dynamic-eid> show ip cef <dynamic-eid> show ip cef <dynamic-eid> internal

Debug commands debug lisp control-plane dynamic-eid debug lisp control-plane link-layer debug lisp forwarding data-signal-discover-dyn-eid

Page 42: Catalyst Backbone and Instant Access Technologies

CiscoRu Cisco CiscoRussia

Ждем ваших сообщений с хештегом#CiscoConnectRu

Пожалуйста, заполните анкеты. Ваше мнение очень важно для нас.

Спасибо

КОД ДЛЯ ОЦЕНКИ ДОКЛАДА -3520

24.11.2014 © 2014 Cisco and/or its affiliates. All rights reserved.