23
Integrated Detector Electronics AS at the European Spallation Source (ESS) Detector Front-end Readout and Application Specific Integrated Circuits Products [email protected] 2014-02-11 Integrated Detector Electronics AS (IDEAS) 1

Ideas ASIC products with possibilities for use in neutron detection

Embed Size (px)

DESCRIPTION

Application of Integrated Detector Electronics (IDEAS) ASICs to neutron detection as defined by the needs of the European Spallation Source, Lund, Sweden.

Citation preview

Page 1: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 1

Integrated Detector Electronics AS at the

European Spallation Source (ESS)

Detector Front-end Readout and Application Specific Integrated Circuits

Products

[email protected]

2014-02-11

Page 2: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 2

IDEAS, http://www.ideas.no

2014-02-11

Page 3: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 3

Overview of the Presentation

Heritage of IDEAS ASICs for Science

IDEAS ASICs for Detector Front-end Readout

Public Information on the Requirements for Detectors at the ESS (from ESS website)

2014-02-11

Page 4: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 4

Heritage of IDEAS ASICs for Science

VA1

1992 20062002 2013

Low noise Viking ASICs

Counters,Spectral counting

SEU/SEL Radiation Tolerant

Comparators& Timing

Low power

1997

Nygard et al. NIMA301 (1991)

ALPHA ATHENA PHOBOS PHOENIX

CLEO NOMAD BELLE

PAMELA AMS1, AMS2 AGILE MEGA

SWIFT STEREO CALET

POLAR ASTROH FOXSI BEPICOLOMBO DAMPE STIX

ANKE PAX R3B

NGRM JUICE HXMT EPM

2014-02-11

ALICE BTEV CREAM

ASIM

AEGIS

Page 5: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 5

IDEAS ASIC Products1 Amplifiers, SH, MUX

2 Comparators, Triggers

3 Data Driven Detector Frontend Readout

4 Counters ICs

5 Current Integrators, CDS, ZDT

6 Analogue Samplers

7 Parallel ADCs and TACs

8 Pixelated ICs

9 Data Acquisition Systems (SoC)

2014-02-11

Page 6: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 6

Amplifiers with SH, MUX, Parallel Out

IDE1162Others:VA2VA140IDE1160, etc.

ApplicationsNuclear Physics and Astrophysics, forSemiconductors, wire chambers, PMTs

2014-02-11

Pulse height

Page 7: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 7

Comparators and Triggers

TA160, can be combined with VA160Combined chip is VATA160 and IDE3160

Trigger output

ApplicationsTrigger, timing

2014-02-11

Page 8: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 8

Amplifiers with Triggers and MUX

2014-02-11

IDE3160

ApplicationPMT readout

Page 9: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 9

Data Driven Detector Frontend Readout

ApplicationsIDE4183 Medical ApplicationsIDE4184 Preclinical ApplicationsIDE4281 Meier et al. Proc. IEEE NSS 2013

2014-02-11

IDE4281

Page 10: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 10

FE-ASIC for Event Counting with external FPGA

2014-02-11

ApplicationsMeier et al. Proc. IEEE NSS 2013

VA64TAP3

IDE3465

Parallel trigger outputs

Page 11: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 11

Event Counting on Chip

ApplicationsIDE3466 in Desorgher et al. RADEM for JUICE, EGU2014Similar ASICs: CA3 in Mikkelsen et al. Proc. IEEE NSS 2008, and

Schlomka et al. Phys. Med. Biol. 53 (2008) 4031 - 4047 2014-02-11

Counters

Page 12: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 12

Current Integrators

VASCM3.2

ApplicationsCommercial Dosimeter System in Radiation TreatmentOestling et al. Nucl. Instr. Meth. A525 (2004)

2014-02-11

2 chips bonded on flex

Page 13: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 13

Pixelated ICs

ApplicationsCastilla et al. (2008), Proc IEEE NSS

VATA211P

32 x 32 pixels, 300µm pitchDiagram of a pixel

2014-02-11

Page 14: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 14

Analogue Samplers

Preamplifier output is continuously sampled. A signal above threshold stops the sampling and samples can be read out.

IDE3421D

Ring sampler or pipeline

Technology and Applications:Gamma spectrometer and camera, Kaye et al. (UoM), Proc. IEEE NSS 2011

2014-02-11

Page 15: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 15

Parallel Digitization on the ASIC

ApplicationsIshikawa et al., IEEE TNS 58 (2011)

IDE3450, IDE3451, IDE3460, IDE3461

Wilkinson A/D Converter

2014-02-11

Page 16: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 16

Timing and Time to Amplitude (TAC)

VATA64HDR16, VASTAT

Time-of-flight (TOF)

Peak-Hold

ApplicationsBagliesi et al., Nucl. Phys. B 215 (2011) 344Zhang, He, Knoll, Wehe, Berry, IEEE TNS 52 (2005)

2014-02-11

Page 17: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 17

Data Acquisition System (SoC)

uCSystemMaster

digital control system

SPI

SENSADC

0 SENSADC15

AUXADC

OUTFSM

VREFVBIAS

NIRDetector

ROIC

SPImiso/mosiscsn / sck

SPImiso/mosiscsn / sck

sensor_ctrl[7:0]

SPImiso/mosiscsn / sck

clock_vector[31:0]

AOUT[15:0]

DOUT[7:0]

TempOUT[3:0]

VREF[7:0]

VBIAS[7:0]

CONTROL-MASTER16b addr / 8b data

IRQ

ApplicationsBerge et al. (IDEAS), NIRCA Abstract, submitted to SPIE Astronomical Instruments 2014

2014-02-11

Page 18: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 18

ESS Instrument Proposals 2012

LoKI – A Broad-Band SANS Instrument

Compact SANS Optimised for Biological Samples

nMX Macromolecular Crystallography

ODIN – Optical and Diffraction Imaging with Neutrons

2014-02-11

From http://europeanspallationsource.se/instrument-proposals-2012-0

Page 19: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 19

LoKI – Broadband SANS

IDEAS can provide detector readout solutions on integrated circuits (ASICs) that • help mitigating the technological risk. The solutions can involve integrated circuits (IC) off-the-shelf or existing designs • to mitigates schedule risks.

From ESS Construction Proposal LoKI, A.J.JacksonAnd Kalliopi Kanaki, 28. Feb. 2013.

2014-02-11

Page 20: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 20

Compact SANS for Biological Samples

Baseline: SANS2D (ISIS) and D33 (ILL) use pixel-cell detectors from ORDELA. With 1cm pitch and discrete electronics readout.

IDEAS designs ASICs for detector readout that enables • very small pixels (microns to centimeter)• reads out many channels (thousands)• reduces the cost per channel (a few EUR per channel)

From ESS Instrument Construction Proposal, Compact SANS, March 1, 2013.

2014-02-11

Page 21: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 21

nMX and ODIN

ASIC Detector Front-end Readout is essential for advanced neutron imaging

2014-02-11

Page 22: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 22

ASICs in 2D Detectors at ILL

ILL, 26.09.2013

ASICs can reduce the cost of detectors.

2014-02-11

Page 23: Ideas ASIC products with possibilities for use in neutron detection

Integrated Detector Electronics AS (IDEAS) 23

From R.H.Wilton, 14.March 2012

Detector Systems at ESS as of 2012

Next: Discussion about FEE Needs at ESS