LYNX TECHNICAL SEMINAR LYNX TECHNICAL SEMINAR
SEMINAR STRUCTURESEMINAR STRUCTURE
FERMAX IP Devices
FERMAX LYNX
VIVO MonitorOperationalfunctions
IP PanelsOperational
functions
Property Management
Unit
Technicalfeatures
Operationalfunctions
Basic System
How to configure
LYNX Overview
IP Relay Decoder
NetworkSwitch
Operationalfunctions
Recommended Specs
SimpleConfiguration
IPEssentials
1. LYNX OVERVIEW1. LYNX OVERVIEW
LYNX = FERMAX IP SYSTEMLYNX = FERMAX IP SYSTEM
A complete IP-Based system which allows to get all the possible features required for any special high-profile project, mainly due to a good electronic design as well as a good looking aesthetic and thanks to the capabilities provided by the advanced IP Technology available nowadays.
A - The best looking aesthetics available in the market
B - The most friendly user experience
C - The easiest to install
PRODUCT STRATEGYPRODUCT STRATEGY
The best looking aesthetics available in the marketThe best looking aesthetics available in the market
• Fermax traditional competitive strength.• High-profile compounds requirement.• Not only for the housing but also the graphic interface.• Customizable features.
1. LYNX OVERVIEW1. LYNX OVERVIEW
1. LYNX OVERVIEW1. LYNX OVERVIEW
The most friendly user experienceThe most friendly user experience
Integrated functions which makes a friendly interface like in standard mobile-phone interfaces:
• OSD Logical interactive menus in all devices• Standard intuitive interaction icons.• Selectable ringtones for each notification. • Touch–Keypad when necessary in VIVO or PMU.• Monitor status LEDs.• System management via computer.• Different profiles for PMU (access levels) • 3.5” display on Panels: Retroview, interactive image.• List of users available (agenda).
1. LYNX OVERVIEW1. LYNX OVERVIEW
The easiest to installThe easiest to installMain devices:Main devices:• Skyline Panels
• Digital• Pushbuttons
• Cityline Panels• 1L Pushbuttons
• Guard Unit (PMU)• Switchers• VIVO Monitors + Connectors
Wiring:Wiring:• Ethernet Cable
• CAT5 / CAT5E / CAT6• RJ-45 connectors
Power Supply:Power Supply:• 12Vdc• PoE (Power over Ethernet)
Optional devices & Features:Optional devices & Features:• IP Relay Decoders• Home Automation• Lift control• 4+N Villa Panels• Home Automation Systems (Gateway recommended)• IP Cameras
Guard Unit
Monitor Monitor
switch
……
……
Monitor Monitor
switch
……
Monitor Monitor
switch
……
Inner Panel
Monitor Monitor
switch
……
……
Monitor Monitor
switch
……
Monitor Monitor
switch
……
Monitor Monitor
switch
…… ……
Monitor Monitor
switch
……
Monitor Monitor
switch
……
switch
switch
Guard Unit
Administrator Guard Unit
…… Block 1 Block 2 Block N
Floor N
Floor 2
Floor 1
General Panel
Block Panel
Block Panel
Block PanelSector
Panel
2. IP ESSENTIALS2. IP ESSENTIALS
LYNXLYNX
PRIVATE LAN
CLASS A IP ADDRESSINGNetwork 10.0.0.0Subnet mask 255.0.0.0Hosts 10.BBB.YYY.XXX
ETHERNET CONNECTION10/100/1000Mbps IEEE 802.3Fiber Optics optionalPoE Available
SIP & RTP PROTOCOL (VoIP)Standard Audio/Video codecs
G.711 (A-Law), G.726H.264
SIP P2P or Server
IP ESSENTIALS BRIEFING FOR LYNX
10.201.100.000
10.200.100.000
10.100.000.001
10.000.000.003
10.000.000.002
10.000.000.001
3. FERMAX IP DEVICES3. FERMAX IP DEVICESVIVO MONITORVIVO MONITOR
GENERALGENERAL
• In-home device for LYNX• Designed by Ramon Benedito• Communication, security & comfort• Full-IP technology• Dimensions:
• 230 (W) x 170 (H) x 20 (D)• User friendly graphic interface. • 7” Touch Screen• 2 Capacitive pushbuttons• 6 Hidden LED-icons• Customizable
• Menu• Background• Applications
• Web server embedded• Flush-box & Wall-mounted connector
32.4
129
130
xx
230
170
20
3. FERMAX IP DEVICES3. FERMAX IP DEVICESVIVO MONITORVIVO MONITOR
OPERATIONAL FUNCTIONSOPERATIONAL FUNCTIONS
Audio/Video communication:Audio/Video communication: Outdoor LYNX panels & PMU
VGA Resolution for video (640 x 480) Other VIVO Monitors (audio only)
Same apartment Different apartments if accepted in a Friend List
On time settings: Brightness/contrast/color Audio volume
Text Messages:Text Messages: Property Management Unit Other VIVO Monitors
Accepted in a Friend List Touch QWERTY keypad available for this function New messages Notified by message led icon Maximum length: 128 characters Storage capacity: 128 messages
Panic distress call:Panic distress call: SOS capacitive button
• Calling to Guard Unit External Panic button / Panic sensor
• Warning message to Guard Unit
Picture capture and memory:Picture capture and memory: Capturing pictures from Panels, PMU, IP Cams Storage capacity: 128 pictures QVGA resolution (320x240) Possibility to download pictures to SD Card.
Doormatic:Doormatic: Doormatic function available Programmable:
• Period of time or permanently
Do not disturb (DND):Do not disturb (DND): DND function available Programmable:
• Period of time or permanently
Audio Notes:Audio Notes: Possibility to record Audio notes Maximum length: 30 seconds each Storage capacity: 300 seconds
Timer:Timer:CountdownTimer function for lapsed warnings
3. FERMAX IP DEVICES3. FERMAX IP DEVICESVIVO MONITORVIVO MONITOR
OPERATIONAL FUNCTIONSOPERATIONAL FUNCTIONS
Home automation managementHome automation management Multi-brand home automation system. 3rd party application management. Acting as a human interface
Sending configuration commandsDisplay status
Video monitoringVideo monitoring Video image from IP Cameras 3rd party IP Cameras compatible (ONVIF) CCTV System behavior
Lift controlLift control Lift calling from apartment Lift destination management
Calls registering:Calls registering: Calls log available:
Calls missed/sent/answeredPossibility to take picture for missed callMissed calls notified by message led iconTotal = 256 (Missed + Received + Sent)
Real time:Real time: Clock indicator. NTP Server configurable for time synchronization
Customization:Customization:Menu
Background colorFunctional icons position
Ringtones:20 different ring tones by default2 custom ring tones can be added by installer Programmable ring-tone for each source call. Maximum ring tone time: 20 seconds
4+N Panel connection:4+N Panel connection:Possibility to connect a 4+N panelConnections available in VIVO connector
3. FERMAX IP DEVICES3. FERMAX IP DEVICESIP PANELSIP PANELS
GENERALGENERAL
• Skyline FERMAX design• Outdoor purposes• Flush / Surface options• Digital / Pushbutton options• Dimensions:
• According to Skyline frames
• New Video & Audio AmplifierNew Video & Audio Amplifier• Full-IP system • Web-Server embedded• Access control connection
• New graphical display availableNew graphical display available• 3,5” TFT Screen• OSD menu. User friendly• Customizable
Skyline LYNX Video ModuleSkyline LYNX Video Module
Skyline LYNX Display ModuleSkyline LYNX Display Module
CAC Direct keypad
VDS/BUS2 pushbutton module
VDS/BUS2 pushbutton module
Skyline LYNX Video ModuleSkyline LYNX Video Module
DIGITAL PANELDIGITAL PANEL
PUSHBUTTON PANELPUSHBUTTON PANEL
VILLA PANELVILLA PANEL
1L Pushbutton Cityline Panel
Proximity reader (Optional)
3. FERMAX IP DEVICES3. FERMAX IP DEVICESIP PANELSIP PANELS
OPERATIONAL FUNCTIONSOPERATIONAL FUNCTIONS
Audio/Video communication:Audio/Video communication: VIVO monitors
• One way video Guard Units (PMU)
• Two ways video Different types of call
• Direct Call (keypad or pushbuttons)• Call through directory (only digital)• Call to guard unit
“Bell button” in digital panelsSpecified button in pushbutton panels
Door opening:Door opening: Two integrated relays
• RELAY 1 , RELAY 2 = 2A@24V Selectable from VIVO and PMU when opening door Selectable for access control option Door opening time settings
Scene illumination:Scene illumination: 6 LEDS crown for lighting Activated when camera is turned on
Picture capture:Picture capture: Automatic capture of visitor Set by VIVO monitor or PMU
Configuration via Web-ServerConfiguration via Web-Server Inbuilt web-server
• Available for PMU or any PC Programming options Firmware update
Voice synthesizer:Voice synthesizer: Voice message for opening notification 32 available languages Activated from:
• PMU | VIVO monitor | Egress button
Access control connection:Access control connection: Secondary reader connection Wiegand / DataClock compatible
• Proximity card reader• Fingerprint reader• Keypad for PIN code
User access control set in DDBB (via PMU)
Hard reset:Hard reset: Hard reset button to reset information stored
3. FERMAX IP DEVICES3. FERMAX IP DEVICESIP PANELSIP PANELS
OPERATIONAL FUNCTIONS (Digital panels, Graphical display)OPERATIONAL FUNCTIONS (Digital panels, Graphical display)
Retroview:Retroview: Optional video reflection of the visitor on TFT Same image as shown by guard/tenant
Customization:Customization: XML file configuration Standard logos
• By default standard logos available• Personal logos can be used.
Personalized messages display:• Custom messages shown on TFT• Individually for each panel
Picture display:• Custom pictures loaded on TFT• *.jpg format • Resolution 320 x 240
Date and Time info:Date and Time info: Information displayed on screen NTP Server configurable for time synchronization Sent to VIVO monitors during conversation
Motion sensor:Motion sensor:To preserve the TFT life and energy consumptionTFT is normally in stand-by mode, switched off.Visitor approaching wakes TFT upDetection field = 1m (adjustable)
OSD Menu:OSD Menu: OSD Menu available to set panel configurationAccess for Menu Options
PIN CODE = 0 + AB21AB + 19025INSTALLER CARD (if card reader available)
Agenda:Agenda: Available users will be shown
• One by one : 1 x Name + additional info• Groups of 4 : 4 x Names
Filtering is also possible Depending on the panel:
• General Entrance: All users shown• Sector Entrance: Sector users shown • Block Entrance: Block users shown
3. FERMAX IP DEVICES3. FERMAX IP DEVICESIP PANELSIP PANELS
GRAPHICAL DISPLAY: TFT PICTURES OVERVIEWGRAPHICAL DISPLAY: TFT PICTURES OVERVIEW
• Calling:Calling:
• Direct Call• Call through directory• Call to Guard Unit
• Communiction in course:Communiction in course:
• Unit does not Exist • Unit busy • Conversation • Retroview • Door opening
• Access control PINAccess control PIN
• CustomizationCustomization
• OSD MENUOSD MENU
3. FERMAX IP DEVICES3. FERMAX IP DEVICESPROPERTY MANAGEMENT UNITPROPERTY MANAGEMENT UNIT
GENERALGENERAL
• PC Multipurpose Software application• Windows OS based• Tool for service provision and system set-up• Maximum User-friendliness & operational convenience• External periferics needed• UI prepared for touch-screen panels
• Big controls and buttons• Windows Keypad available
• Functions determined by user login profile:• INSTALLER / ADMIN / GUARD
It develops Guard Unit functions :• Receiving/sending calls or messages• Managing alarm warnings and panic calls
It develops Setting-up functions :• Events registering/consulting• Managing general system database
PMU
3. FERMAX IP DEVICES3. FERMAX IP DEVICESPROPERTY MANAGEMENT UNITPROPERTY MANAGEMENT UNIT
TECHNICAL SPECSTECHNICAL SPECSFermax Lynx Property Management Unit is recommended to be installed in a Panel PC Station.Nevertheless, it can also be installed in any standard PC with minimum requirements running over Windows 7, Vista or XP.
3. FERMAX IP DEVICES3. FERMAX IP DEVICESPROPERTY MANAGEMENT UNITPROPERTY MANAGEMENT UNIT
OPERATIONAL FUNCTIONSOPERATIONAL FUNCTIONS
Audio/Video communication:Audio/Video communication: Outdoor LYNX panels and Other PMU:
Two ways videoUp to 5 simultaneous incoming callsTime-out to answer: 30 seconds
VIVO Monitors: One way video (PMU-VIVO)House call reception queue: 128 calls
On time settings:Brightness/contrast/colorAudio volume
Text Messages:Text Messages: Other Property Management Unit VIVO Monitors
Touch QWERTY Unicast / Multicast No friend-list acceptation needed.
New messages Notified by pop-up window Maximum length: 128 characters
Alarms management:Alarms management:ALARM RECEPTIONALARM RECEPTION
• Apartment and outdoor alarms• Panic distress calls• Tamper/sabotage detection• Maximum priority, notified by pop-up window• Call-back action available• (Optional) Automatic SMS to owner
Picture capture and recording:Picture capture and recording: Recording Audio/Video during call
• Audio from VIVO• Maximum length: 90 seconds
SMS:SMS: GSM-Modem needed. Telephone number List of external services List of users
Set by installer, numbers are not shown.
Customization:Customization: 10 predefined bell tones Different bell tones for each notification
3. FERMAX IP DEVICES3. FERMAX IP DEVICESPROPERTY MANAGEMENT UNITPROPERTY MANAGEMENT UNIT
OPERATIONAL FUNCTIONSOPERATIONAL FUNCTIONS
Operation modes:Operation modes: FULL service:FULL service:It will receive calls from panels and will filter all the calls from panels assigned HOUSES service:HOUSES service:It will receive calls from apartments and also from panels if only the bell button is pressed. OFF service:OFF service:The PMU will not receive any call
Events log:Events log:All actions are registeredChecking available only for admin profilePossibility to print or export to Excel file
Profile functions:Profile functions:Installer profile (2)To set up and configure the parameters of the installation and perform functionality tests Administrator profile (10)To create and erase accounts and set up operational options Guard profile (100)For normal operation mode. No system paremeters can be modified
Lift control:Lift control:Lift control configuration from PMUPMU can send any Lift to any floor
Application blocking:Application blocking: Blocking application for temporary absence. Incoming Calls can be transferred to other PMU
System configuration:System configuration: Database management
Static: agenda, names, addressesDinamic: Events log
VIVO & Panels. Configuration by Web-Server
FULLFULL HOUSESHOUSES OFFOFF
3. FERMAX IP DEVICES3. FERMAX IP DEVICESPROPERTY MANAGEMENT UNITPROPERTY MANAGEMENT UNIT
PMU SCREEN CAPTURES:PMU SCREEN CAPTURES:
• LoginLogin
• SettingsSettings• Installer settings• Profiles• User settings
• Incoming callsIncoming calls• From door panel• From apartment• From Guard Unit PMU
• Queued callsQueued calls• Pending messages• Pending calls
• PANIC calls
• CallingCalling• To apartment• To door panel• To Guard Unit PMU
• MessagesMessages• Sending messages• Alarm notifications
3. FERMAX IP DEVICES3. FERMAX IP DEVICESIP Network SWITCHIP Network SWITCH
GENERALGENERAL
• IP Switches are not provided by FERMAX
• Compatibility with most switch trademarks
• Preferably PoE and QoS support.
• No special configuration needed for LYNX
• Wide range of Network Switches:• 4 / 8 / 16 / 24 /… Ports
NETWORK SWITCH:NETWORK SWITCH:A network switch or switching hub is a computer networking device that connects network segments or network devices. The term commonly refers to a multi-port network bridge that processes and routes data to its corresponding port in a local area network.
3. FERMAX IP DEVICES3. FERMAX IP DEVICESIP Network SWITCHIP Network SWITCH
NETWORK SWITCH RECOMMENDATIONS for LYNX:NETWORK SWITCH RECOMMENDATIONS for LYNX:
Endspan:Endspan:The switch (Power Sourcing Equipment, PSE) shall provide power on the Ethernet cable itself, without the need of using a midspan.
PoE support:PoE support:IEEE 802.3af (up to 15.4W)Optional: IEEE 802.3at (up to 25.5W) PoE+.
Number of ports:Number of ports:4/8/16 ports 10/100 BASE-T (10/100 Mbps)Price depends mostly on the number of ports.
Coverage:Coverage:Data transmission up to 100 m in Ethernet segments.Optional: 5 km in fiber optical segments.Optional: 150m or 250m in Ethernet segments.
•Bandwidth10/100MbpsOptional: 1000Mbps, 10Gbps
Bandwidth:Bandwidth:10/100MbpsOptional: 1000Mbps, 10Gbps
Form factor & Temperature:Form factor & Temperature:Desktop or DIN rail mountedTemperature: -20ºC to 70ºC
Quality of Service (QoS):Quality of Service (QoS):Good QoS support for simultaneous video & audio streaming channels.
• Traffic prioritization (IEEE 802.1p)• Layer 4 prioritization (based on TCP/UDP port number)
IPv6:IPv6:Optional: not necessary at a first stage, but may be in the future.
Multicast support:Multicast support:IGMP snooping: Internet Group Management Protocol Optional: MLD (if IPv6 supported)
Management:Management:At least one configuration method supported:
serial console, CLI, web or SNMP. Switches will be configured from factory.Switches will be configured from factory.
Optional: remote in-field management via SNMP
Monitoring:Monitoring:Optional: port mirroring or SMON (nice-to-have).
Backup power supply:Backup power supply:The switch shall support the possibility to be connected to an UPS or backup battery, so as to keep on working in the case of a power outage.
SWITCHES - EXAMPLES:SWITCHES - EXAMPLES:
FERMAX
Ref.1617 – Switch LYNX Cisco (4 PoE + 4)Ref.1618 – Switch LYNX Cisco (8 PoE + 8)
3. FERMAX IP DEVICES3. FERMAX IP DEVICESIP Network SWITCHIP Network SWITCH
3. FERMAX IP DEVICES3. FERMAX IP DEVICESIP RELAY DECODERIP RELAY DECODER
GENERALGENERAL
• Dry contact integration in LYNX systems• Standard protocol Modbus• DIN rail mounted•Two different modules: MASTER and SLAVE
MASTERMASTER• 4 dry contact relays available • LED status available• It can work as an individual IP relay decoder for dry contacts activation and also as Modbus Gateway for a whole bus of relay slave modules.
SLAVESLAVE• 10 dry contact relays available• It works as slave module and upon request from IP Master module handle 10 dry contacts for each unit.
MASTER Ref.1615MASTER Ref.1615
SLAVE Ref.1615SLAVE Ref.1615
3. FERMAX IP DEVICES3. FERMAX IP DEVICESIP RELAY DECODERIP RELAY DECODER
OPERATIONAL FUNCTIONSOPERATIONAL FUNCTIONS
Lift controlLift control• Main device for lift control features• MASTER Receives TCP/IP coded instructions-:
• PMU – Property Management Unit• VIVO Monitors• Digital IP Panels
• SLAVE receives activation instructions from MASTER via Modbus RS-485• Dry contacts signal • LYNX integration with most of the lift systems
Secure door opening:Secure door opening:• Door opening from relay modules instead of Panel relays. • For special anti-vandal features: security
Additional functions:Additional functions:• Flexibility for multiple tasks
• For Example: Switch On/Off stair lights
CONNECTION:CONNECTION:10.203.000.000 Module 1 Module 32
4. FERMAX LYNX4. FERMAX LYNXEssentialsEssentials
LYNX TECHNOLOGY SPECS:LYNX TECHNOLOGY SPECS:
* SIP ServerAvailable soon
4. FERMAX LYNX4. FERMAX LYNXEssentialsEssentials
INSTALLATION FEATURES:INSTALLATION FEATURES:
Capacity:Capacity:
Distances, Wiring:Distances, Wiring:
4. FERMAX LYNX4. FERMAX LYNXEssentialsEssentials
INSTALLATION FEATURES:INSTALLATION FEATURES:
Fiber OpticsFiber OpticsDifferent types of standard connectorsDifferent types of standard connectors
Ethernet - Straight cableEthernet - Straight cable““To connect different type of devices (PC-to-switch, To connect different type of devices (PC-to-switch,
PC-to-router ..) you use Straight Through cable”PC-to-router ..) you use Straight Through cable”
Connectors:Connectors:
4. FERMAX LYNX4. FERMAX LYNXEssentialsEssentials
INSTALLATION FEATURES:INSTALLATION FEATURES:
4. FERMAX LYNX4. FERMAX LYNXEssentialsEssentials
INSTALLATION FEATURES:INSTALLATION FEATURES:
IP AddressingIP Addressing (Transparent to user)
PRIVATE IP ADDRESS – TYPE APRIVATE IP ADDRESS – TYPE A 10.BBB.XXX.YYY10.BBB.XXX.YYYBBBBBB TYPETYPE SETTINGSSETTINGS
000…099 MonitorMonitor BBB = Block number = 100 blocks
XXX.YYY = Terminal number (256x256 = 65536 per Block)•3 MSB bits: inside apartment monitor number (max. 8)•13 LSB bits: apartment number (max. 8.192)
Default: 10.000.000.001 = 10.000.00000000.00000001
100…199 Indoor apartment panelsIndoor apartment panels BBB = Block number = 100 blocks
XXX.YYY= Terminal number. (256x256= 65536 per Block)•3 MSB bits: inside apartment panel number (max. 8)•13 LSB bits: apartment number (max. 8.192)
Default: 10.100.000.001 = 10.100.00000000.00000001
200 Outdoor panelsOutdoor panels XXX:• 000 … 099 – Block number (100 Blocks)• 100 – General Entrance• 200 – Sector Entrance = General entrance for specific blocks
YYY:• 000 … 099 – Panel number (100 per Block / General Entrance)
Default: 10.200.100.000
INSTALLATION FEATURES:INSTALLATION FEATURES:
BBBBBB TYPETYPE SETTINGSSETTINGS
201 Guard UnitsGuard Units XXX:• 000 … 099 – Block number (100 Blocks)• 100 – General Guard Unit• 200 – Sector Guard Unit = General Guard Unit for specific blocks
YYY:• 000 … 099 – Guard Unit number (100 per Block / General Entrance)
Default: 10.201.100.000
203 Relay DecoderRelay Decoder XXX : 000 … 099 - Block number (100 Blocks)
YYY : 000 … 255 – Relay Decoder number (255 Relay Decoders per Block)
Default: 10.203.000.000
204 ServersServers XXX : Functionality (001 = SIP Server)
YYY : Server number
Default: 10.204.000.000
205 Emergency PanelEmergency Panel XXX : 000 … 099 Block Number (100 Blocks)
YYY : 000 … 255 Panel Number (255 Emergency Panels per Block)
Default: 10.205.000.000
10.BBB.XXX.YYY10.BBB.XXX.YYY
4. FERMAX LYNX4. FERMAX LYNXEssentialsEssentials
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 1: Project Data CollectionSTEP 1: Project Data Collection
PROJECT: PROJECT: ITS BUILDINGITS BUILDING
General Entrance Panels: 1General Entrance Guard Units: 1Internal Blocks: 2Internal Entrance Panels: 1/BlockInternal Entrance Guard Units: NoApartments: 17/Block
4/Floor + 1Lift Control: YesFloors: 5
Additional specs:1. General Entrance Panel
DigitalCard reader access available
2. Internal panels with pushbuttons3. Top apartments (x2):
Indoor Apartment panel: 1PB for Apartment1PB for Guard Unit
Home Automation System (InDomo)
FERMAX DATA COLLECTION SHEET
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 2: Wiring designSTEP 2: Wiring design
PROJECT: PROJECT: ITS BUILDINGITS BUILDING
Bandwith considerations:Bandwith considerations:
Available Bandwith• Net structure will be tipically Fast Ethernet:
• BW = 100Mbps• Fiber optic links will be tipically Gigabit Ethernet:
• BW = 1000Mbps
Bandwith consumption• Audio conversation:
• G.711 = 64Kbps• G.726 = 32kbps
• Video conference: • H.264 = 5Mbps (VGA)
• Switch (Layer 2 device) distributes packets only to the corresponding output.
• Two conversations which are using different switches, are not sharing the bandwith.
• Two conversations using same switch (bottleneck) will share the bandwith
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 2: Wiring designSTEP 2: Wiring design
PROJECT: PROJECT: ITS BUILDINGITS BUILDING
Bandwith considerations:Bandwith considerations:
HOW MANY CONVERSATIONS WILL BE AVAILABLE THROUGH THE BOTTLENECK?
Fast Ethernet switch: BW = 100MbpsAudio codec G.711 = 64kbpsVideo codec H.264 = 5Mbps
20 videoconferences1500 audio conversations
100Mbps
Huge compounds - avoid bottlenecks connecting additional switchers to split up the communcations path.
Example10 Video conferences: 10 x 5Mbps = 50Mbps.10 Audio conversations: 10 x 64kbps = 0’64Mbps.Total: 51Mbps -> 49Mbps remaining in the bottleneck
!!
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 2: Wiring designSTEP 2: Wiring design
PROJECT: PROJECT: ITS BUILDINGITS BUILDING
Fail-Safe considerations – Redundancy (optional)Fail-Safe considerations – Redundancy (optional)
• Network Redundancy avoids the system goes down due to fails in one link.• Switches will always select the best way to route a packet using Spanning Tree adaptative protocol
“If you have a single point of failure and it fails, then you have nothing to rely on. If you put in a secondary (or tertiary) method of access, then when the main connection goes down, you will have a way to connect to resources and keep the business operational.” – Robert J. Shimonski
Redundant links improves system behaviour against link fails
Redundant switch
If this link fails, some devices will be out of communication
?? ?
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 2: Wiring designSTEP 2: Wiring design
PROJECT: PROJECT: ITS BUILDINGITS BUILDING
FO Ethernet Cat-5 RJ45
Fiber Optic SMF FDDI
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 3: Bill of Quantities (BOQ)STEP 3: Bill of Quantities (BOQ)
PROJECT: PROJECT: ITS BUILDINGITS BUILDING
FERMAX References:FERMAX References:
GENERAL ENTRANCE (x1)
1 x Ref.1622 – LYNX Amplifier Skyline1 x Ref.1623 – LYNX TFT Graphical Display1 x Ref.7457 – CAC Direct Keypad1 x Ref.7440 – Proximity Reader Module1 x Ref.7337 – Skyline Frame 7V S81 x Ref.8858 – Flush-mounted box S81 x Ref.1610 – LYNX Property Management Unit2 x Ref.4813 – Power Supply Unit 12Vdc/2ª2 x Ref.2060 – Emergency Battery adapter
INTERNAL BLOCK (x2)
2 x Ref.1622 – LYNX Amplifier Skyline1 x Ref.1623 – LYNX TFT Graphical Display2 x Ref.7371 – 8 double VDS/BUS2 Pushbutton Skyline2 x Ref.7368 – 2 simple VDS/BUS2 Pushbutton Skyline1 x Ref.7337 – Skyline Frame 7V S81 x Ref.7333 – Skyline Frame 3V S4 1 x Ref.8858 – Flush-mounted box S81 x Ref.8854 – Flush-mounted box S417 x Ref.1600 – LYNX VIVO Monitor17 x Ref.1605 – LYNX VIVO Connector1 x Ref.1615 – LYNX MASTER Relay Decoder1 x Ref.1616 – LYNX 10 Output Relay decoder (Slave)2 x Ref.4813 – Power Supply Unit 12Vdc/2ª2 x Ref.2060 – Emergency Battery adapterSwitches and networking elements requiredSwitches and networking elements required
Depending on the installation topology.Depending on the installation topology.-Ref. 1617: Switch 4 PoE + 4Ref. 1617: Switch 4 PoE + 4-Ref. 1618: Switch 8 PoE + 8Ref. 1618: Switch 8 PoE + 8
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: INSTALLATION AND CONFIGURATIONSTEP 4: INSTALLATION AND CONFIGURATION
FO
Ethernet Cat-5 RJ45
Fiber Optic SMF FDDI
SECTION 1: Cabling and SwitchingSECTION 1: Cabling and Switching
Endpoints
Closets
NO CONFIGURATION REQUIRED ON SWITCHERS
ROUTING and REDUNDANCY: Spanning-Tree Protocol
Ethernet Cat-6 RJ45
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: INSTALLATION AND CONFIGURATIONSTEP 4: INSTALLATION AND CONFIGURATION
SECTION 2: RELAY DECODERSSECTION 2: RELAY DECODERS
MASTER - At office via Software: NetIOConfigToolNetIOConfigTool
• Connect SERIAL PORT RS-232 cable
2. Run application NetIOConfigTool and set COM port:SERIAL PORT : COM1BAUD RATE: 9600bpsDATA BIT: 8STOP BIT: 1PARITY: NONEFLOW: NONE
Serial RS-232
3. Press OPEN to open communications4. Press READ to get the paramenters5. Set paramenters
1. DEV IP: 10.203.Block.Group2. MASK: 255.0.0.03. WORK MODE: TCP4. LOCAL PORT: 270005. Web-Server: (optional)
6. Press WRITE to save settings
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: INSTALLATION AND CONFIGURATIONSTEP 4: INSTALLATION AND CONFIGURATION
SECTION 2: RELAY DECODERSSECTION 2: RELAY DECODERS
SLAVE - At office via Software: MODBUS RTU ADDRESS CONFIG TOOLMODBUS RTU ADDRESS CONFIG TOOL
1. Connect RS-485 Cable Interface (Ref.24661)
2. Run application and set COM port:SERIAL PORT: COMXBAUD RATE: 9600bpsDATA BIT: 8STOP BIT: 1PARITY: NONEFLOW: NONE
3. Press OPEN to open communications4. Press READ to get Modbus address5. Set new address (1 to 254)6. Press WRITE to save settings
RS-485 / USB2466124661
• LIFT CONTROL is set by using SLAVES (MASTER relays are reserved for additional functions)• Use of Lift will be set in Guard Unit / Panel / Monitor once Relay decoders have been set properly • Up to 320 relays/floors, using Slaves
LIFT CONTROL LIFT CONTROL NOTESNOTES
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: INSTALLATION AND CONFIGURATIONSTEP 4: INSTALLATION AND CONFIGURATION
SECTION 2: RELAY DECODERSSECTION 2: RELAY DECODERS
The LIFT CONTROLLIFT CONTROL configuration screens in (Monitors / Panels / PMU) support the following relay addressing scheme. A relay is no further defined by a single number, but a triplet.
GROUP NUMBER
The IP module inside the block (Last byte of the address: [0..254]).
MODULE NUMBER
Address of the module in the RS-485 bus: [1..32]. 255 = the IP module.
OFFSET 1 of the 4 relays in the module: [0..3] (in the IP module).1 of the 10 relays in the module: [0..9] (in the 485 module)
Relay number / floor = Group + Module + OffsetRelay number / floor = Group + Module + Offset
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: INSTALLATION AND CONFIGURATIONSTEP 4: INSTALLATION AND CONFIGURATION
SECTION 3: PROPERTY MANAGEMENT UNITSECTION 3: PROPERTY MANAGEMENT UNIT
ADMIN PC – Installer SettingsADMIN PC – Installer Settings
1. Install USB-Key: • Install drivers and Software
• Windows 7• SQL Server (DDBB Engine)• Property Management Installation• Click-Once Installation Wizard
2. Set valid name and address: • By default: USER “installer”, PASS “123”
3. Installer settings:• Settings Wizard for first time
• General settings• PMU settings• Maintenance settings
• Set LIFT CONTROL information:• Send one command to every lift
• Panel custom settings (optional)• Logos + Pictures + Messages
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: INSTALLATION AND CONFIGURATIONSTEP 4: INSTALLATION AND CONFIGURATION
SECTION 3: PROPERTY MANAGEMENT UNITSECTION 3: PROPERTY MANAGEMENT UNIT
PMS Wizard Installer.mp4
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: INSTALLATION AND CONFIGURATIONSTEP 4: INSTALLATION AND CONFIGURATION
SECTION 3: PROPERTY MANAGEMENT UNITSECTION 3: PROPERTY MANAGEMENT UNIT
Admin SettingsAdmin Settings
Set admin settings – (Administrator task)• Logins
• Guards/Admins/Alarms
• Agenda• User’s Database
• Lift settings• Available lifts must be set
previously by installer
• Events Log• Events storage options
• SMS services settings• Services via SMS
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: System ConfigurationSTEP 4: System Configuration
SECTION 4: GENERAL ENTRANCE DIGITAL PANELSECTION 4: GENERAL ENTRANCE DIGITAL PANEL
OSD MenuOSD Menu• Dial “0” + “AB21AB” + “19025”• Configuration Menu
• Panel Settings• Block, lifts, General Entrance
• Audio Settings• Audio levels
• Call settings•
•Presentation• Customization
• Access Control• Secondary reader
Web-ServerWeb-Server• 10.200.0.0 IP by default• Configuration Menu
• Basic Setup• Advanced Setup• Look & Feel• System Management
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: System ConfigurationSTEP 4: System Configuration
SECTION 4: GENERAL ENTRANCE DIGITAL PANELSECTION 4: GENERAL ENTRANCE DIGITAL PANEL
Panel Display Options.mp4
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: System ConfigurationSTEP 4: System Configuration
SECTION 5: INTERNAL BLOCK PUSHBUTTON PANELSSECTION 5: INTERNAL BLOCK PUSHBUTTON PANELS
Web-ServerWeb-Server• 10.200.0.0 IP by default• Configuration Menu
• Basic Setup• Advanced Setup• Look & Feel• System Management
NOTE1: Intelligence resides on Video/Audio module. When it is connected, it detects which elements are connected:
• TFT + Keypad = Digital panel = General entrance• Pusbuttons = Pushbutton panel = Internal block
NOTE2: Web-server will show the corresponding options:Depending on the panel it will show
• TFT Customization options (Digital panel)• Pushbuttons address options (Pushbutton panel)
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: System ConfigurationSTEP 4: System Configuration
SECTION 5: INTERNAL BLOCK PUSHBUTTON PANELSSECTION 5: INTERNAL BLOCK PUSHBUTTON PANELS
Panel Web Options.mp4
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: System ConfigurationSTEP 4: System Configuration
SECTION 6: APARTMENTS, VIVO MONITORSSECTION 6: APARTMENTS, VIVO MONITORS
Web-ServerWeb-Server• 10.0.0.1 IP by default• Configuration Menu
• Basic Setup• Advanced Setup• Look & Feel• System Management
OSD Screen MenuOSD Screen Menu• User Options
• Ringtones• Background• Language• Camera• Date and Time• Password (1111 by default)• Communication options• Installer options
• Password (4444 by default)• Monitor settings• Lift settings• Home automation• Sensor settings• Reset• Applications• SD-Card
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: System ConfigurationSTEP 4: System Configuration
SECTION 6: APARTMENTS, VIVO MONITORSSECTION 6: APARTMENTS, VIVO MONITORS
Monitor Options.mp4
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
STEP 4: System ConfigurationSTEP 4: System Configuration
BRIEFINGBRIEFING
1. Cabling and Switching • Follow the wiring design• No special configuration required on switchers
2. Relay Decoders configuration• Master IP Relay via software (NetIOConfig)• Slave IP Relay via software (MODBUS RTU)
3. PMU settings• Install software (SQL-Server + PMU)• Basic configuration using wizard• Set lifts• Set Admin features
4. Digital panels• From OSD Menu or Web-server• Set Type, Area, Block and Number• Set custom features
5. Pushbutton panels• From Web-server• Set Type, Block, Number• Set pushbutton numbers• Set custom features
6. VIVO monitors• Set Block, Floor, Number• Set Server address (ADM-PC)• Set custom features
4. FERMAX LYNX4. FERMAX LYNXSystem configurationSystem configuration
FINISHFINISH
PROJECT: PROJECT: ITS BUILDINGITS BUILDING
FO Ethernet Cat-5 RJ45
Fiber Optic SMF FDDI
10.1.0.1 10.1.0.2 10.1.0.3 10.1.0.4
10.1.0.5 10.1.0.6 10.1.0.7 10.1.0.8
10.1.0.9 10.1.0.10 10.1.0.11 10.1.0.12
10.1.0.13 10.1.0.14 10.1.0.15 10.1.0.16
10.2.0.1 10.2.0.2 10.2.0.3 10.2.0.4
10.2.0.5 10.2.0.6 10.2.0.7 10.2.0.8
10.2.0.9 10.2.0.10 10.2.0.11 10.2.0.12
10.2.0.13 10.2.0.14 10.2.0.15 10.2.0.16
10.2.0.1710.1.0.17
10.200.1.0 10.200.2.0
10.200.100.0
10.201.100.0
10.203.1.0 10.203.2.0
International Technical DepartmentInternational Technical Department