3
Efficient installations 2-poles installation contactor Thermal current: 32 A Rated current AC-1: 32 A AC remote control Installation contactor for applications such us residential, hospitals, hotels and business premises Fast switching of motors, electric heating, lights and lighting, all kind of electrical and electronic equipment Mounting on 35 mm rail Degree of protection IP20 Installation Contactor IKA232-20/230 V Series 200 Advanced operation Other benefits

Manual IKA232-20-230V

Embed Size (px)

Citation preview

Page 1: Manual IKA232-20-230V

Efficient installations

2-poles installation contactor

Thermal current: 32 A

Rated current AC-1: 32 A

AC remote control

Installation contactor for applications such us residential, hospitals, hotels and business premises

Fast switching of motors, electric heating, lights and lighting, all kind of electrical and electronic equipment

Mounting on 35 mm rail

Degree of protection IP20

Installation ContactorIKA232-20/230 V

Series 200

Advanced operation

Other benefits

Page 2: Manual IKA232-20-230V

Installation ContactorIKA232-20/230 V

Technical data IKA232-20/230 VGeneral

Main circuit

Standard

Rated insulation voltage

1

4

63 x 10

32

-15 ... +55

230

-40 ... +80

50/60

max.3

32

NO: 9 ; NC: 6

32 / 24 V / 1 pole

max.240 - 50 °C

17 V; > 50 mA

3.6

7.0

NO: 1.3 ; NC: 0.75

1 ... 10

100.000

NO: 150.00 ; NC: 100.000

300.000

1 ... 6

M3.5

PZ1

1.2

2.5

72

32

300

600

3000

0.13

IEC/EN 60947-4-1, IEC/EN 61095

440

Module width (1 module width = 17.5 mm)

Rated impulse withstand voltage

Mechanical endurance

Thermal current

Ambient temperature

Rated operational voltage

Storage temperature

Rated frequency

No. of contactors side-by-side

Rated operational current

Rated operational current

Rated operational current

< 40 °C

AC-1 - Non-inductive or slightly inductive loads, resistance furnaces

AC-3 - Squrrel-cage motors, starting: switching off during running

DC-1 -Non-inductive or slightly inductive loads, resistive furnaces

AC-7a - Slightly inductive loads in household appliances and similar applications

AC-7b - Motor-loads for household applications

Contact reliability

Operational power for AC-1/AC-7a

Operational power for AC-3/AC-7b

Electrical endurance for DC-1

Electric endurance for AC-1/AC-7a

Electric endurance for AC-3/AC-7b

Terminal capacity

Screw

Screw head

Tigtening torque

Min. distance of open contacts

Power dissipation per pole

Overcurrent withstand capability

Max. back-up fuse for short-circuit protection gG (gL) - coordination type 1

Max. operating frequency

AC-1/AC-7a/AC-3/AC-7b/lamp loads

single-phase 230 V

single-phase 230 V

rigid

flexible

L/R < 1 ms

No load

DC-1

Weight

°C

V

°C

Hz

mm

W

kW

W

op.c.

op.c.

op.c.

A

A

V

kV

A

A

A

A

kg

Iv

Ui

Ith

Ie

Ie

Ie

S 2mm

Nm

Pe

Pe

Ue

f

Uimp

Efficient installations

Page 3: Manual IKA232-20-230V

Dimensions

Contact arrangements

Operation position

• Published by Iskra, d. d. • Version 1.0 October 2015

www.iskra.eu

Installation ContactorIKA232-20/230 V

Technical data IKA232-20/230 VControl circuit

Range of control voltage

AC

230

50/60

2

15 - 25

1 ... 2.5

2.8 / 1.2

10 - 30

1 ... 2.5

2

0,6

85 ... 110

Kind of voltage

Control voltage

Frequency (AC)

Surge immunity test (1.2/ 50 µs) acc. to IEC/EN 6100-4-5

Coil consumption

Delays

Terminal capacity

Surge immunity test (1.2/ 50 µs) acc. to IEC/EN 6100-4-5

Tighening torque

Hz

Uc

Uc

f

S

%

V

kV

VA/W

ms

2mm

kV

Nm

make

rigid

operation

break

flexible

A2 2 4

A1 1 3

IKA232-20/ 230 V

15° 15°180° 15° 15°

4585

17.5

35

5

60

44

Ordering data

IKDA32 – 20 / 230 V

Control voltage

Version of contacts

Type