This presentation shows maps of a very large plume of fugitive methane capture by Picarro in a drive-by emissions check in the town of Flower Mound 10 minutes from the Dallas-Fort Worth International Airport. The plumes were so elevated that the Picarro gas analyzer maxed out its readings -- likely environmental levels of fugitive methane were higher than in the chart. This may also imply extremely high levels of toxic VOCs such as benzene and xylene, both of which are often associated with methane in fugitive emissions resulting from petrochemical and natural gas installations. Alisa Rich of Wolf Eagle Environmental created this presentation using data gathered with a Picarro analzyer.
Citation preview
Methane Mapping, Flower Mound, Texas
Alisa Rich, Wolf Eagle Environmental
Flower Mound, Tx - Wind DataMarch 2, 2010
Measurements taken @ 8-10 pm
Wind from the NW
Flower Mound, looking downwind
• Source isolated to this area
Methane: +40 ppm
• Closest peaks saturated the instrument (> 40 ppm)
• Peaks get broader and lower further downwind
Methane: +40 ppm
Flower Mound, looking cross-wind
Flower Mound, looking upwind• Downwind peak (in
foreground) is about five miles from the source area, and the methane level is +4.5 ppm