ABUTMENT VENTILATION SYSTEMS · Glidevale’s range of abutment ventilation is at the core of an...

Preview:

Citation preview

4640. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ABUTMENT VENTILATION SYSTEMS

CI/SfB (47) Uniclass L529February 2015

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GLIDEVALE LIMITED2 Brooklands Road, Sale, Cheshire M33 3SS Tel: 0161 905 5700 Fax: 0161 905 2085Email: info@glidevale.com Web: www.glidevale.com

Glidevale Limited maintains a policy of continuous development and reserves the right to amend product specifications without notice.

A division of Building Product Design Ltd. Company Registration No; 3944123

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Stockist’s stamp

Glidevale’s range of abutment ventilation isat the core of an unrivalled capability.Glidevale also offer the widest range ofslate tile and ridge, eaves and valleyventilation solutions to compliment theabutment ventilation range for both newbuild and refurbishment projects. Glidevale is the ‘one stop shop’ for roofventilation solutions.

Other productsGlidevale underfloor and cavity wallventilators.

Glidevale loft access traps/ladder.

Glidevale Sunscoop tubular rooflights.

In-line Ridge Ventilators

G Range and In-line Tile and Slate Ventilators

MR50 Monovent with AluFlash

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Glidevale abutment ventilationsystems have beendesigned to provide a range

There are two primary methods of

providing the ventilation at high level at

abutments, either via the roof covering

in discrete units such as G range or

In-line ventilators or the use of

unobtrusive continuous systems

using the Glidevale Monoventand AbVent ranges.

Both systems provide full compliance

with BS 5250 Control of Condensation

in Buildings, the primary means to

comply with Building Regulations in

the UK as well as providing driving rain

and large insect resistance.

of solutions to provide high levelventilation into roofspaces in anunobtrusive way.

AV50 AbVent with AluFlash

AV50 AbVent

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Eaves Ventilators

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MR50 MONOVENT

MR50 Monovent provides unobtrusive ventilation to top edge abutments of lean-to roofs.

The innovative design ensures a continuous ventilation gap of5000mm2/m. MR50 Monovent is recommended be used inconjunction with Glidevale eaves ventilation systems to ensurethrough ventilation of the roof space from low to high level. Whenused with Type LR underlays such as Protect VP400 Plus LR it canalso be used on its own to provide the ventilation requirement.

The Glidevale AV50 AbVent provides unobtrusive high-level

ventilation and can be used in conjunction with traditional ‘lead roll’ details on plain tile and slate roofs. It is also particularly useful in top edge abutmentsituations where MR50 Monovent cannot beinstalled because of limited vertical clearance.

● Guaranteed 5000mm2/m ventilation provision to comply with BS 5250 and Building Regulations.

● Deluge and driving rain resistant as well as preventing large insect ingress.

● Suitable for installation under dormer window sills when insulation is at rafter level.

● Unobtrusive when installed. Hidden within the roof flashings.

● Available with integral AluFlash the revolutionary lead free alternative.

● Each unit overlaps the next to ensure integrity of flashing.

● Quick and easy to install.

BENEFITS

● Guaranteed 5000mm2/m ventilation provision to comply with BS 5250 and Building Regulations.

● Deluge and driving rain resistant as well as preventing large insect ingress.

● Unobtrusive when installed. Hidden within the roof flashings.

● Available with integral AluFlash the revolutionary lead free alternative.

● Each unit overlaps the next to ensure integrity of flashing.

● Quick and easy to install. Does not affect the normal laying of the roof covering.

● Minimum pitch 20o.

BENEFITS

Specification clauseInstall Glidevale MR50Monovent at roof/wallabutment to provideventilation of5000mm2/m inaccordance withBuilding Regulationsand BS 5250. Install continuously asshown on drawings,and fix in accordancewith manufacturer’sinstructions.

Composition, ManufactureThe unit comprises two PVC-Uextruded sections supplied in 1.22mlengths complete with spacers,screws, washers and clips. AluFlashapron flashing for dressing over thetiles is supplied. A lead or AluFlash cover flashing (notsupplied) must be installed with MR50Monovent (as shown below), inaccordance with the recommendationsof the Lead Sheet Association orAluFlash. Horizontal cavity trays with short leador AluFlash cover flashing provide acomplete solution in new buildconstruction. MR50 Monovent can also be suppliedwith code 4 lead flashing to order.

Composition, ManufactureManufactured from ABS. All exposed surfaces are treated witha uv-resistant polymeric resin.AluFlash apron flashing for dressingover the tiles is supplied. A lead or AluFlash cover flashing (notsupplied) must be installed with AV50AbVent (as shown). Horizontal cavity trays with short leador AluFlash cover flashing provide acomplete solution in new buildconstruction. AV50 AbVent can also be supplied withcode 4 lead flashing to order.

AV50 ABVENT

Horizontal cavity traywith integral short leador AluFlash coverflashing

Fixing position of MR50 Monoventvaries according to roof pitch

Protect VP400 Plus LR underlay

Lower extrusion

Spacer bracket

MR50 Monovent

Top extrusion

AluFlash or Code 4 lead flashingto order

Protect roofingunderlay

Lead roll ridge

Code 4 or 5 leador AluFlash

Glidevale AV50 AbVent

Protect roofing underlay

Limited height top edge abutment

Window sill

Glidevale AV50 AbVent

AluFlash or Code 4 leadto order

Protect roofingunderlay

Flat to pitched roof junction

Code 4 or 5 leador AluFlash

Glidevale AV50 AbVent

Specification clauseInstall Glidevale AV50AbVent underleadroll*/top edgeabutment* /with/without integralAluFlash flashing* toprovide ventilation tothe roofspaceequivalent to5000mm2/m inaccordance withBuilding Regulationsand BS 5250.

. . . . . . . . . .

Install continuously asshown on drawing andfix in accordance withmanufacturer’sinstructions*Delete as appropriate

Recommended