View
2
Download
0
Category
Preview:
Citation preview
ROOF HATCHES
AUTOMATIC SMOKE VENTS
FLOOR DOORS
SAFETY PRODUCTS
HorizontalAccessProducts
We have just the opening for you!
Uniclass EPIC
CI/SfB
L41 D1
(37.5) X2010
77969 Revised - Covers:Layout 1 29/2/12 16:51 Page 2
Our Commitment
Bilco products are designed and fabricated to con-sistently high quality standards to ensure completecustomer satisfaction.
As part of its commitment, Bilco has implementeda company-wide quality system, which hasachieved ISO 9001 and 14001 accreditation. TheBilco Company is committed to producing accessproducts that are unequalled in quality, design, andworkmanship.
Our Guarantee
Warranty is for a minimum period of ten yearsfrom the date of purchase. Electric motors, specialfinishes, and other special equipment, if applicableare covered separately.
Bilco UK, Bury St. Edmunds, Suffolk, England
Bilco History
The Bilco Company was established in America in1926 and has for many decades designed and sup-plied access products for construction and engi-neering industries all over the world. Under thesame family ownership the Company has been apioneer in the development of a unique line of hori-zontal access products.
In 1989, Bilco UK & Europe was formed and hasbuilt a reputation amongst architects, engineers,specifiers, and the construction trades for provid-ing the right access solution.
Bilco Today
Based in Suffolk, Bilco can supply the trade with arange of standard roof hatches, smoke vents, andfloor doors in various sizes and materials directfrom stock, delivered by a nationwide pallet-linesystem or dedicated consignment. Standard itemsare delivered anywhere in the UK in 3-4 workingdays and best of all, there’s no extra charge. If aspecial product is required, the fast-track shopallows delivery in an industry leading 4-6 weeks.
Bilco also provides technical assistance for morecomplex product requirements. The technicaldepartment will assist you to develop a creativedesign solution for your unique applications. Qualityaccess products comply with current BuildingRegulations & Legislation, and are engineered toprovide many years of trouble-free service.
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - page 2:Layout 1 29/2/12 16:52 Page 1
Automatic Smoke Vents 14-15
Contents
Roof Access Hatches 4-5
Floor Doors 26-27
Safety Products 13 &35
Bil-Guard® Hatch Rail System 13
LadderUp® Safety Post 35
Floor Door Fall Protection Grating 35
Ladder Access Type S, Type E 6
Ladder Access Type GS 7
Ship Stair Type NB 8
Service Stair Type L, Type SSY 9
Refurbishment VersaMount® 10
Security Access Security Series 11
Plant Access Type D, Type F, Type SS 12
Roof Hatch Options 24-25
Drainage Doors Type J-AL, JD-AL 28
Drainage Doors Type J-ALH20, JD-ALH2O 29
Non-Drainage Doors Type K, KD 30
Non-Drainage Doors Type TER, TRD 31
Fire Doors Type J-FR 32
Fire Doors Type FR 33
Floor Door Options 34
Solid Covers Single Leaf 140° 16
Solid Covers Single Leaf 90° 17
Translucent Single Leaf 90° 18
Translucent Double Leaf 90° 19
Special Sizes Type D-50REM 20
Acoustic Type ACDSH 21
Controls 22-23
Smoke Vent & Roof Hatch Options 24-25
77969 Revised - page 2:Layout 1 29/2/12 16:52 Page 2
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Roof Hatches
4
Bilco roof hatches provide safe and convenient roof access by means of an interior ladder, ship stair, or service stair.Larger sized hatches are also available to facilitate the easymovements of equipment to and from a building. Eachaluminium hatch comes with a 10 year guarantee.
The curb upstand is manufactured with a cap-flashing thatincludes the Bilclip® flashing system which accepts a varietyof felts and membranes. As a result installation time andrelated costs are greatly reduced and a more effectivemechanical termination which does not rely on adhesives aloneis provided. Alternatively a metal curb liner can be specified tomake site installation easier, ideally suited for hot-works, wetapplied waterproofing and standing seam roofs.
Customised designs are also available which can featuresecurity options, motorised operation, a range of paint finishesand safety aids.
Rugged hold-open armautomatically locks thecover in the openposition. Grip handleallows for easy, one-hand release andclosing.
Fully insulated coverand curb. 50mm thickfaced rigidpolyisocyanuratethermal insulationboard. U value of0.47Wm2/K
Curb Liners - Hatches can be fitted with curb liners tomake site installation easier. See suffix CL.
New enhanced
Typical Applications
Banks
Prisons
Factories
Fast Food Restaurants
Gymnasiums
Hospitals
Hotels
High-Rise Housing
Office Buildings
Manufacturing Plants
Schools
Shopping Centres
Storage Facilities
Distribution Depots
Warehouses
Key Features & Benefits
Weathertight construction
Fully insulated and gasketed forenergy efficiency
Lift assistance for smooth, easy,one-hand operation
Corrosion resistant hardware
Bilclip® Flashing System forease of installation
Custom sizes and options arereadily available
Meets the requirements ofmanual handling regulations
Hatches can be specified withcurb liners
Heavy duty slam latchsecurely locks cover inthe closed position.Interior and exteriorhasps provide additionalsecurity
77969 Revised - pages 4-13:BLC366 UK CATALOG 29/2/12 17:01 Page 4
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com 5
Bilco’sexclusive
YEARWARRANTY
10
Insulated curbwith cap flashingand Bilclip®flashing system.Installation issimply a matterof placing thehatch over theroof opening andsecuring it to theroof deckthrough theholes providedin the baseflange. Theintegralcapflashingreadily acceptsroofingmembranesreducinginstallation timeand costs.
Fully enclosed compression springscounter balance the cover for smooth,easy and controlled operationregardless of cover size or weight.Bilco hatches meet the requirements ofManual Handling Regulations
specification on all roof access hatches!
Interior channel reinforcingmembers are welded in place forcover strength and rigidity.
Top sidelatch withturn handleand padlockhasp
Newly designed closed cell EPDM spongegasket, helps meet Building Regulations airleakage targets by providing a better sealof the cover to the curb, ensuringcomplete weather-tightness. Air leakageperformance 4.83m3/hr/m2 @ 600 PaTested to BS EN 12207: 2000
Thermal insulation board
Capflashing
Meets BS EN12207Curb
Membrane(adhered to itself) Bilclip®
Bilclip®flashing system
77969 Revised - pages 4-13:BLC366 UK CATALOG 29/2/12 17:01 Page 5
mm8383mm
®
50mm Polyisocyanurate
Hinge
Insulation throughout cover
Cover
and Compression Springs
and Padlock HaspCombination Lock Strike
Capflashing and BilclipCurb with integral
and Cover Release
Red Vinyl Grip
Cover Liner
Automatic Hold Open Arm
Reinforced Composite Tubes
and Padlock HaspsInside-Outside Handles
(All Around)Gasket
Spring Latch with
Lifting Mechanism with
50mm PolyisocyanurateInsulation around outsideof curb
114mmmm114
mm187
mm
70°
305
915mm
Untitled-1 1 11/12/08 16:00:58
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Type S-50T
Ladder Access
6
Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the cover shall be smooth and easy with controlled operation throughout the entire arc of opening and closing.
Operation of the cover shall not be affected by temperature.
Entire hatch shall be weathertight with fully welded corner joints on cover and curb.
Cover: 2.3mm aluminium with a 100mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K. Insulation shall be fully covered and protected by
an aluminium liner.
Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip® flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place.
Curb Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K.
Lifting Manufacturer shall provide compression spring operators mechanisms: enclosed in telescopic tubes to provide smooth, easy, and
controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent accumulation of moisture, grit, and debris inside the lower tube assembly. The lower tube shall interlock with a flanged support shoe that is bolted to the curb assembly.
Hardware: Heavy pintle hinges shall be provided.
Cover shall be equipped with a spring latch with interior and exterior turn handles.
Shall be equipped with interior and exterior padlock hasps.
The latch strike shall be bolted to the curb assembly.
Cover shall automatically lock in the open position with a rigid hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing.
Compression spring tubes shall be an anti-corrosive composite material and all other hardware shall be zinc plated and chromate sealed. Springs shall be manufactured from steel and packaged in grease for corrosion resistance. [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space.
Finishes: Factory finish shall be mill finish aluminium.
Options: See page 24
SPECIFICATIONSFurnish and install where indicated on plans metal roof hatch. Length denotes hinge side. These roof hatches shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer.
Type Size - clear internal dimensions Overall Dimensions Weight
S-50T 915mm x 760mm (H) 1143mm x 988mm 50 kg
S-50T CL 915mm x 760mm (H) 1143mm x 988mm 56 kg
E-50T 915mm x 915mm 1143mm x 1143mm 53 kg
E-50T CL 915mm x 915mm 1143mm x 1143mm 60 kg
50 - Aluminium (H) - Hinge Side CL - Curb Liner
Special sizes and materials - galvanized, copper, lead clad and stainless steel, available on request.
STANDARD SIZES & WEIGHTS Performance
BS EN 12207:2000 Air Permeability4.83 m3/hour/m2 at 600 Pa
BS EN 12208:2000 Water Tightness Class 9A
BS EN 12210:2000 Wind Resistance Class E2400
BS EN 1991-1 Snow Load 1200Pa for 1 hour
BS 8200 Impact Resistance Pass
BS EN ISO 140 Acoustic 25dB
BS EN 1627 – 1630 Security Pass
Wind Speed With Open Cover 30 m/s
NOTE – Copies of Taylor Woodrow Developments test reports for S-50Tproduct available on request.
TYPE S-50T & TYPE E-50T - AluminiumEasy one-handed operation to fully open or closed position provides the user the security of having one handfirmly on the ladder at all times.
Type E-50TShown withoptionalBilcoLadderUP®
Safety Post
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 4-13:BLC366 UK CATALOG 29/2/12 17:02 Page 6
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
TYPE GS-50T - AluminiumAll the security and convenience of the Type S roof hatch with the added benefits of a skylight. GS Roof Hatches feature aluminium construction and virtually indestructible polycarbonate domes.
Ladder Access
SPECIFICATIONS Furnish and install where indicated on plans metal roof hatch. Length denotes hinge side. The roof hatch shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer.
Type Size - clear internal dimensions Overall Dimensions Weight
GS-50T 915mm x 760mm (H) 1143mm x 988mm 92 kg
GS-50T CL 915mm x 760mm (H) 1143mm x 988mm 98 kg
GSS-50T Special sizes on request
STANDARD SIZES & WEIGHTS
Type GS-50T
Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m2.
Operation of the cover shall be smooth and easy with controlled operation throughout the entire arc of opening and closing.
Operation of the cover shall not be affected by temperature.
Entire hatch shall be weathertight with fully welded corner joints on cover and curb.
Cover: Aluminium extrusion with built in drainage channel and clear polycarbonate double skin dome. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip® flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place.
Curb Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K.
Lifting Manufacturer shall provide compression spring operators mechanisms: enclosed in telescopic tubes to provide smooth, easy, and
controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent accumulation of moisture, grit, and debris inside the lower tube assembly. The lower tube shall interlock with a flanged support shoe that is bolted to the curb assembly.
Hardware: Heavy pintle hinges shall be provided.
Cover shall be equipped with a spring latch with interior and exterior turn handles.
Shall be equipped with interior and exterior padlock hasps.
The latch strike shall be bolted to the curb assembly.
Cover shall automatically lock in the open position with a rigid hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing.
Compression spring tubes shall be an anti-corrosive composite material and all other hardware shall be zinc plated and chromate sealed. Springs shall be manufactured from steel and packaged in grease for corrosion resistance. [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space.
Finishes: Factory finish shall be mill finish aluminium.
Options: See page 24
7
50 - Aluminium (H) - Hinge Side CL - Curb Liner
Special sizes available on request.
Shown withoptionalBilcoLadderUP®
Safety Post
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 4-13:BLC366 UK CATALOG 29/2/12 17:02 Page 7
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Type NB-50T
TYPE NB-50T - AluminiumIdeal for installations where frequent use may be expected. Permits easier movement of maintenancepersonnel, tools and equipment.
Lifting Manufacturer shall provide compression spring operators mechanisms: enclosed in telescopic tubes to provide smooth, easy, and
controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent accumulation of moisture, grit, and debris inside the lower tube assembly. The lower tube shall interlock with a flanged support shoe that is bolted to the curb assembly.
Hardware: Heavy pintle hinges shall be provided.
Cover shall be equipped with a spring latch with interior and exterior turn handles.
Shall be equipped with interior and exterior padlock hasps.
The latch strike shall be bolted to the curb assembly.
Cover shall automatically lock in the open position with a rigid hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing.
Compression spring tubes shall be an anti-corrosive composite material and all other hardware shall be zinc plated and chromate sealed. Springs shall be manufactured from steel and packaged in grease for corrosion resistance. [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space.
Finishes: Factory finish shall be mill finish aluminium.
Options: See page 24
SPECIFICATIONS Furnish and install where indicated on plans metal roof hatch. Length denotes hinged side. The roof hatch shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer.
Type Size - clear internal dimensions Overall Dimensions Weight
NB-50T 760mm x 1370mm (H) 988mm x 1598mm 63 kg
NB-50T CL 760mm x 1370mm (H) 988mm x 1598mm 71 kg
Ship Stair Access
STANDARD SIZES & WEIGHTS
8
Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the cover shall be smooth and easy with controlled operation throughout the entire arc of opening and closing.
Operation of the cover shall not be affected by temperature.
Entire hatch shall be weathertight with fully welded corner joints on cover and curb.
Cover: 2.3mm aluminium with a 100mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K. Insulation shall be fully covered and protected by
an aluminium liner.
Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip® flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place.
Curb Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K.
PerformanceBS EN 12207:2000 Air Permeability
4.83 m3/hour/m2 at 600 Pa
BS EN 12208:2000 Water Tightness Class 9A
BS EN 12210:2000 Wind Resistance Class E2400
BS EN 1991-1 Snow Load 1200Pa for 1 hour
BS 8200 Impact Resistance Pass
BS EN ISO 140 Acoustic 25dB
BS EN 1627 – 1630 Security Pass
Wind Speed With Open Cover 30 m/s
NOTE – Copies of Taylor Woodrow Developments test reports for S-50Tproduct available on request.
50 - Aluminium (H) - Hinge Side CL - Curb Liner
Special sizes and materials - galvanized, copper, lead clad and stainless steel, available on request.
83mm83mm
50mm Polyisocynurate
of curbInsulation around outside
and Compression Springs
Hinge
Cover
Combination Lock Strike
Spring Latch with
Gasket(All Around)
50mm Polyisocyanurateand Padlock Hasps
Cover Liner
Insulation throughout coverInside-Outside Handles
Red Vinyl Grip
Automatic Hold Open Arm
and Padlock Hasp
and Cover Release
Lifting Mechanism withReinforced Composite Tubes
Curb with integralCapflashing and Bilclip®
305mm
187mm
87°
760mm
114mm 114mm
Untitled-1 1 11/12/08 16:07:27
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 4-13:BLC366 UK CATALOG 29/2/12 17:02 Page 8
TYPE L-50T & SSY-50T - AluminiumFor where frequent use may be expected. Permits easier movement of maintenance personnel, tools andequipment from a full size stairway.
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Service Stair Access
SPECIFICATIONS Furnish and install where indicated on plans metal roof hatch. Length denotes hinged side. These roof hatches shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer.
Type Size - clear internal dimensions Overall Dimensions Weight
L-50T 760mm x 2440mm (H) 988mm x 2668mm 115 kg
L-50T CL 760mm x 2440mm (H) 988mm x 2668mm 128 kg
SSY-50T 760mm x 3360mm (H) 988mm x 3588mm 142 kg
SSY-50T CL 760mm x 3360mm (H) 988mm x 3588mm 158 kg
STANDARD SIZES & WEIGHTS
Type L-50TType L-50T
Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the cover shall be smooth and easy with controlled operation throughout the entire arc of opening and closing.
Operation of the cover shall not be affected by temperature.
Entire hatch shall be weathertight with fully welded corner joints on cover and curb.
Cover: 2.3mm aluminium with a 100mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K. Insulation shall be fully covered and protected by
an aluminium liner.
Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip® flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place.
Curb Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K.
Lifting Manufacturer shall provide compression spring operators mechanisms: enclosed in telescopic tubes to provide, smooth, easy, and
controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent accumulation of moisture, grit, and debris inside the lower tube assembly. The lower tube shall interlock with a flanged support shoe that is bolted to the curb assembly.
Hardware: Heavy pintle hinges shall be provided.
Cover fitted with enclosed two point spring latch with interior andexterior turn handles.
Shall be equipped with interior and exterior padlock hasps.
The latch strike shall be bolted to the curb assembly.
Cover shall automatically lock in the open position with a rigid hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing.
Compression spring tubes shall be an anti-corrosive composite material and all other hardware shall be zinc plated and chromate sealed. Springs shall be manufactured from steel and packaged in grease for corrosion resistance. [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space.
Finishes: Factory finish shall be mill finish aluminium.
Options: See page 24
9
PerformanceBS EN 12207:2000 Air Permeability
4.83 m3/hour/m2 at 600 Pa
BS EN 12208:2000 Water Tightness Class 9A
BS EN 12210:2000 Wind Resistance Class E2400
BS EN 1991-1 Snow Load 1200Pa for 1 hour
BS 8200 Impact Resistance Pass
BS EN ISO 140 Acoustic 25dB
BS EN 1627 – 1630 Security Pass
Wind Speed With Open Cover 30 m/s
NOTE – Copies of Taylor Woodrow Developments test reports for S-50Tproduct available on request.
Type SSY-50T
50 - Aluminium (H) - Hinge Side CL - Curb Liner
Special sizes and materials - galvanized and stainless steel, available on request.
83mm 83mm
Cover Liner
Red Vinyl Grip
Gasket(All Around)
Inside-Outside Handles
and Compression Springs
Hinge
Reinforced Composite Tubes
50mm PolyisocyanurateInsulation around outsideof curb
50mm Polyisocyanurate
Material as cover
Insulation throughout cover
Enclosure, Same
Cover
Two Point Lock
and PAdlock Hasps
Lock Strike
Automatic Hold Open Armand Cover Release
Padlock Hasp
Lifting Mechanism with
Spring Latch with
Curb with integralCapflashing and Bilclip®
mm411mm411
87°
187mm305mm
760mm
Untitled-1 1 11/12/08 16:07:56
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 4-13:BLC366 UK CATALOG 29/2/12 17:02 Page 9
and Padlock Hasp
Automatic Hold Open Arm and Cover Release
CoverGasket
Red Vinyl Grip
(All Around)
Insulation throughout cover50mm Polyisocyanurate
Hinge
around outsideFiberboard Insulation25mm Rigid
Cover Liner
of curb
Spring Latch withInside-Outside Handles
and Padlock Hasps(Handles to be installed
on site by customer)
Combination Lock Strike
Anchor Clips
915mm
87°
140mm
67mm
78mm
38mm
78mm
Lifting Mechanism withReinforced Composite Tubes
and Compression Springs
Untitled-1 1 11/12/08 16:09:04
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Type S-50VMT - Optional anodized finish shown
Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the cover shall be smooth and easy with controlled operation throughout the entire arc of opening and closing.
Operation of the cover shall not be affected by temperature.
Entire hatch shall be weathertight with fully welded corner joints on cover and curb.
Cover: Shall be 2.3mm aluminium with a 100mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K. Insulation shall be fully covered and protected by
an aluminium liner.
Curb: Shall be 102mm in height and of 2.3mm aluminium. The curb shall be formed with a 67mm flange and a 38mm apron, fully welded at corners. Stainless Steel anchor clips are included. Bilco recommend maximum upstand width is 65mm
Curb Shall be polyisocyanurate of 25mm thickness with a U-value of insulation: 0.87 W/m2K.
Lifting Manufacturer shall provide compression spring operators mechanisms: enclosed in telescopic tubes to provide smooth, easy, and
controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent accumulation of moisture, grit, and debris inside the lower tube assembly. The lower tube shall interlock with a flanged support shoe that is bolted to the curb assembly.
Hardware: Heavy pintle hinges shall be provided.
Cover shall be equipped with a spring latch with interior and exterior turn handles.
Shall be equipped with interior and exterior padlock hasps.
The latch strike shall be bolted to the curb assembly.
Cover shall automatically lock in the open position with a rigid hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing.
Compression spring tubes shall be an anti-corrosive composite material and all other hardware shall be zinc plated and chromate sealed. Springs shall be manufactured from steel and packaged in grease for corrosion resistance. [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space.
Finishes: Factory finish shall be mill finish aluminium.
Options: See page 24
SPECIFICATIONS Furnish and install where indicated on plans metal roof hatch. Length denotes hinge side. The roof hatch shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer.
Type Size - clear internal dimensions Overall Dimensions Weight
S-50VMT 915mm x 760mm (H) 1071mm x 916mm 46 kg
Refurbishment
STANDARD SIZES & WEIGHTS
10
PerformanceBS EN 12207:2000 Air Permeability
4.83 m3/hour/m2 at 600 Pa
BS EN 12208:2000 Water Tightness Class 9A
BS EN 12210:2000 Wind Resistance Class E2400
BS EN 1991-1 Snow Load 1200Pa for 1 hour
BS 8200 Impact Resistance Pass
BS EN ISO 140 Acoustic 25dB
BS EN 1627 – 1630 Security Pass
Wind Speed With Open Cover 30 m/s
NOTE – Copies of Taylor Woodrow Developments test reports for S-50Tproduct available on request.
TYPE VERSAMOUNT®
The VersaMount® is ideal for refurbishment projects where a weather proof upstand is existing. Easy tofit the anchor clip system and versatile frame design helps complete the job efficiently.
50 - Aluminium (H) - Hinge Side
Special size not available
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 4-13:BLC366 UK CATALOG 29/2/12 17:02 Page 10
Untitled-1 1 11/12/08 16:09:04
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Security Access
50 - Aluminium (H) - Hinge Side CL - Curb Liner
Special sizes and materials - galvanized and stainless steel, available on request.
STANDARD SIZES & WEIGHTS
Type S-50CT - Optional Tnemec finish shown
Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the cover shall be smooth and easy with controlled operation throughout the entire arc of opening and closing.
Operation of the cover shall not be affected by temperature.
Entire hatch shall be weathertight with fully welded corner joints on cover and curb.
Cover: Shall be 5mm aluminium with a 100mm beaded flange with formed reinforcing members. Cover shall have a heavy extrudedEPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K. Insulation shall be fully covered and protected by
an aluminium liner.
Curb: Shall be 305mm in height and of 5mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners.
Curb Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K.
Lifting Manufacturer shall provide compression spring operators mechanisms: enclosed in telescopic tubes to provide smooth, easy, and
controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent accumulation of moisture, grit, and debris inside the lower tube assembly. The lower tube shall interlock with a flanged support shoe that is bolted to the curb assembly.
Hardware: Heavy pintle hinges shall be provided.
Cover shall be equipped with a spring latch with interior and exterior turn handles.
Shall be equipped with interior and exterior padlock hasps.
The latch strike shall be bolted to the curb assembly.
Cover shall automatically lock in the open position with a rigid hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing.
Springs shall be manufactured from steel and packaged in grease for corrosion resistance. All other hardware shall be zinc plated and chromate sealed [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space.
Finishes: Factory finish shall be mill finish aluminium.
Options: See page 24
11
SPECIFICATIONS Furnish and install where indicated on plans metal Security Series roof hatch. Length denotes hinge side. The roof hatch shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer.
TYPE SECURITY SERIESConstructed of heavier gauge materials for high security applications such as prisons, banks, embassies,and pharmaceutical buildings. A variety of lock options as well as security glazing is also available.
Type Size - clear Overall Openinternal dimensions Dimensions Weight angle
S-50CT 915mm x 760mm (H) 1143mm x 988mm 68 kg 70°
E-50CT 915mm x 915mm 1143mm x 1143mm 80 kg 70°
NB-50CT 760mm x 1370mm (H) 988mm x 1598mm 95 kg 90°
SS-50CT Special sizes on request
PerformanceBS EN 12207:2000 Air Permeability
4.83 m3/hour/m2 at 600 Pa
BS EN 12208:2000 Water Tightness Class 9A
BS EN 12210:2000 Wind Resistance Class E2400
BS EN 1991-1 Snow Load 1200Pa for 1 hour
BS 8200 Impact Resistance Pass
BS EN ISO 140 Acoustic 25dB
BS EN 1627 – 1630 Security Pass
Wind Speed With Open Cover 30 m/s
NOTE – Copies of Taylor Woodrow Developments test reports for S-50Tproduct available on request.
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 4-13:BLC366 UK CATALOG 29/2/12 17:02 Page 11
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Type F-50T standard hatch
Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the cover shall be smooth and easy with controlled operation throughout the entire arc of opening and closing.
Operation of the cover shall not be affected by temperature.
Entire hatch shall be weathertight with fully welded corner joints on cover and curb.
Cover: 2.3mm aluminium with a 100mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K. Insulation shall be fully covered and protected by
an aluminium liner.
Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip® flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place.
Curb Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K.
Lifting Manufacturer shall provide compression spring operators mechanisms: enclosed in telescopic tubes to provide smooth, easy, and
controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent accumulation of moisture, grit, and debris inside the lower tube assembly. The lower tube shall interlock with a flanged support shoe that is bolted to the curb assembly.
Hardware: Heavy pintle hinges shall be provided.
Cover shall be equipped with a spring latch with interior and exterior turn handles. Double leaf and single leaf covers over 2133mm have a 2-point spring latch system.
Shall be equipped with interior and exterior padlock hasps.
The latch strike shall be bolted to the curb assembly.
Cover shall automatically lock in the open position with a rigid hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing.
Compression spring tubes shall be an anti-corrosive composite material and all other hardware shall be zinc plated and chromate sealed. Springs shall be manufactured from steel and packaged in grease for corrosion resistance. [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space.
Finishes: Factory finish shall be mill finish aluminium.
Options: See page 24
SPECIFICATIONSFurnish and install where indicated on plans metal roof hatch. These roof hatches shall be single leaf and/or double leaf and shall be pre-assembled from the manufacturer.
50 - Aluminium CL - Curb Liner Special sizes available on requestType SS - Single LeafType D - Double Leaf
Plant Access
STANDARD SIZES & WEIGHTS
12
Type D double leaf roof hatch for larger openings,over 2135mm in width.
D-50T
TYPE F-50T, TYPE SS-50T & TYPE D-50TThere are a wide range of options for plant access making it easy to install or remove equipmentfrom a building.
Type Size - clear internal dimensions Overall Dimensions Weight
F-50T 1220mm x 1220mm 1448mm x 1448mm 99 kg
F-50T CL 1220mm x 1220mm 1448mm x 1448mm 109 kg
D-50T Special sizes on request
SS-50T Special sizes on request
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 4-13:BLC366 UK CATALOG 29/2/12 17:02 Page 12
Bil-Guard Hatch Rail System
13
STANDARD SIZES & WEIGHTS Type Size - Overall Weight Hatch
clear internal dimensions Dimensions type
RL-S 915mm x 760mm (H) 1285mm x 1130mm 24 kg S
RL-E 915mm x 915mm 1285mm x 1285mm 24 kg E
RL-F 1220mm x 1220mm 1590mm x 1590mm 28 kg F
RL-NB 760mm (H) x 1370mm 1130mm x 1815mm 28 kg NB
RL-L 760mm (H) x 2440mm 1130mm x 2885mm 35 kg L
Plan ViewShown without hatch coverA = hatch opening widthB = hatch opening length
Isometric ViewType RL-S shown on Type S roof hatch
SPECIFICATIONSPosts and rails are pultruded from a fire retardant, fibreglass-reinforced polymer (FRP). FRP material has amoulded-in, high visibility, safety yellow colour and is treated with a UV inhibitor. Mounting brackets arefabricated from 6mm thick hot dip galvanized steel. Gate hinges and post guides are constructed of 6063-T5 aluminium and torsion rod is Type 302 stainless steel. All fasteners are Type 316 stainless steel.Manufacturer shall provide a 25-year warranty against defects in material and workmanship.
ROOF SAFETYSYSTEMBil-Guard® is a fixed railingsystem that provides apermanent means of fallprotection for hatch andsmoke vent openings. It canalso help provide continuousprotection especially wheremansafe systems have beeninstalled on the roof area. Bil-Guard® features aninnovative attachment systemthat does not penetrate theroofing membrane and onstandard hatches pre-drilledholes in the capflashing acceptthe mounting brackets. Bil-Guard® can be installedquickly and easily using basictools.
Hin
ge s
ide
B +
368
mm
nom
A + 368mm nomA
B
Top of railto be set107cmabove theroofsurface ordeck
Key Features & Benefits
Corrosion resistant - 25-yearwarranty
High visibility safety yellow colour
Non-penetrating attachment
Pivoting mounting sleeve forinstallation flexibility
Standard self-closing gate feature
Available in a variety of sizes
Fits all Bilco roof hatches
Easily installed on new or existinghatches and smoke vents (H) - Hinge Side Special sizes can also be manufactured
Pivoting mountingsleeve for installationflexibility
Self-closing gatehinge ensurescontinuous protection
Quick-mountbracket for fast,secureattachment
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com 13
77969 Revised - pages 4-13:BLC366 UK CATALOG 29/2/12 17:02 Page 13
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Smoke Vents 95% of all fire
14
Type EEW-50REM
Typically positioned at the head of astairwell or smoke shaft. The vent will actas a chimney clearing the building of heatand smoke.
Typical Applications
High-Rise Housing
Offices and Commercial Buildings
Aircraft Hangars
Auditoria
Concert Halls and Theatres
Convention Centres
Gymnasiums
Manufacturing Plants
Retail Centres
Schools
Hospitals
Distribution Depots
Warehouses
Bilco smoke vents are designed to satisfy Building Regulationsand meet Approved Document B, BS 9999 (which supercedesBS5588) and European Standards enshrined in EN 12101.
For the EN 12101 keyareas of theregulations are thatthe covers must reachthe fire open positionwithin 60 seconds andthat single coversopen to 140° toensure there are nonegative wind co-efficients ie windblowing smoke backinto the building.
Bilco smoke vents arealso compatible withother guidance andcodes of practices,for example thoseissued by the BritishResearchEstablishment such asBRE 79204.
The new range ofBilco smoke ventshave all beenthermally enhancedand a higherperformance gaskethas been introduced.
Key Features & Benefits
Increased evacuation time anddecreased risk of smokeinhalation and damage
Enhanced visibility to allowfirefighters to quickly locate thefire
Protection against secondaryignitions and lateral fire spread
Exhausting of noxious andpotentially explosive fumes
Structure protection fromdamaging heat
Reduce damage to buildingcontents
Can be used for access andcomfort ventilation
Approved Document B - The diagram above depicts atypical stand alone system which is installed in a 4 storeybuilding stairwell with the ventilator positioned at the headof the stair and control systems within the stairwell.
Fully insulated coverand curb. 50mm thickfaced rigidpolyisocyanuratethermal insulationboard. U value of0.47Wm2/K
Flange with 10 pre-drilledfixing points for easyinstallation
Entire vent shall beweathertight with fullywelded corner joints oncover and curb.
A single linear actuatormounted on a pivotingcarriage capable ofopening the cover to thefire open position of 140degrees within 60seconds.
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:02 Page 14
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com 15
related deaths result from smoke inhalation
Bilco’sexclusive
YEARWARRANTY
10
Insulated curbwith capflashing and Bilclip® flashingsystem.Installation issimply a matterof placing thevent over theroof openingand securing itto the roof deckthrough theholes providedin the baseflange. Theintegralcapflashingreadily acceptsroofing feltsreducinginstallation timeand costs.
Thermal insulation board
Capflashing
Meets BS EN12207Curb
Membrane(adhered to itself) Bilclip®
Bilclip®flashing system
Newlydesignedclosed cellEPDMspongegasket,helps meetBuildingRegulations air leakage targetsby providing a better seal ofthe cover to the curb, ensuringcomplete weather-tightness.
Curb mountedjunction box withterminal blockenclosed forpower cableconnection.
Enclosed hinge assembly
Standard product- clear vent areasof 1m2 and 1.5m2
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:02 Page 15
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Type EEW-50REM
TYPE REM SMOKE VENTS - Single Leaf 140°Electric actuation for remote opening & closing.
SPECIFICATIONSThe smoke vent shall be single leaf and provide 1m2 or 1.5m2 clear vent area. The smoke vent shall be pre-assembled from the manufacturer.
50 - Aluminium (H) - Hinge Side CL - Curb Liner
Smoke Vents - Solid Covers
STANDARD SIZES & WEIGHTS - Single Leaf 140°
16
Bilco’sexclusive
YEARWARRANTY
10
Type Size - clear internal dimensions Overall Dimensions Weight Clear Vent Area
ENB-50REM 760mm x 1620mm (H) 988mm x 1848mm 118 kg 1m2
ENB-50REM CL 760mm x 1620mm (H) 988mm x 1848mm 127 kg 1m2
EEW-50REM 1000mm x 1250mm (H) 1228mm x 1478mm 120 kg 1m2
EEW-50REM CL 1000mm x 1250mm (H) 1228mm x 1478mm 129 kg 1m2
EFW-50REM 1250mm x 1500mm (H) 1478mm x 1728mm 143 kg 1.5m2
EFW-50REM CL 1250mm x 1500mm (H) 1478mm x 1728mm 154 kg 1.5m2
EHW-50REM 1000mm x 1750mm (H) 1228mm x 1978mm 195 kg 1.5m2
EHW-50REM CL 1000mm x 1750mm (H) 1228mm x 1978mm 206 kg 1.5m2
ESS-50REM Min 760mm x Consult UK Office for sizing 1.5m2 max
ESS-50REM CL Min 760mm x Consult UK Office for sizing 1.5m2 max
Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the cover shall be through a 24VDC battery backed control system that will open the cover to the fire open position within 60 seconds and be capable of closing the cover.
Operation of the cover shall not be affected by temperature.
Entire vent shall be weathertight with fully welded corner joints on cover and curb.
Cover: Shall be 2.3mm aluminium with a 100mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket that is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K. Insulation shall be fully covered and protected by
an aluminium liner.
Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip®
flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place.
Curb insulation: Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m2K.
Operating A single linear actuator mounted on a pivoting carriage capable of mechanism: opening the cover to the fire open position of 140 degrees.
(Note – roof obstructions should be considered – alternative products opening to 90°)
Hardware: Heavy pintle hinges shall be provided.
Curb mounted junction box with a terminal block enclosed for power cable connection.
Finishes: Factory finish shall be mill finish aluminium.
Controls: See page 22
Options: See page 24
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:02 Page 16
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
TYPE REM SMOKE VENTS - Single Leaf 90°Electric actuation for remote opening & closing.
50 - Aluminium (H) - Hinge Side CL - Curb Liner *Springs included on larger sizes
Smoke Vents - Solid Covers
STANDARD SIZES & WEIGHTS - Single Leaf 90°
17
Bilco’sexclusive
YEARWARRANTY
10
SPECIFICATIONSThe smoke vent shall be single leaf and shall be pre-assembled from the manufacturer.
Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip® flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place.
Curb insulation: Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m2K.
Operating Two 24VDC linear actuators capable of opening the cover to the mechanism: fire open position of 90 degrees. (Note – alternative products
opening to 140°)
Hardware: Heavy pintle hinges shall be provided.
Curb mounted junction box with a terminal block enclosed for power cable connection.
Finishes: Factory finish shall be mill finish aluminium.
Controls: See page 22
Options: See page 24
Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the cover shall be through a 24VDC battery backed control system that will open the cover to the fire open position within 60 seconds and be capable of closing the cover.
Operation of the cover shall not be affected by temperature.
Entire vent shall be weathertight with fully welded corner joints on cover and curb.
Cover: Shall be 2.3mm aluminium with a 100mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket that is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K. Insulation shall be fully covered and protected by
an aluminium liner.
Type UEW-50REM
Type Size - clear internal dimensions Overall Dimensions Weight Clear Vent Area
UNB-50REM 760mm x 1620mm (H) 988mm x 1848mm 113 kg 1.23m2
UNB-50REM CL 760mm x 1620mm (H) 988mm x 1848mm 122 kg 1.23m2
UEW-50REM 1000mm x 1250mm (H) 1228mm x 1478mm 115 kg 1.25m2
UEW-50REM CL 1000mm x 1250mm (H) 1228mm x 1478mm 124 kg 1.25m2
UFW-50REM 1250mm x 1500mm (H) 1478mm x 1728mm 138 kg 1.88m2
UFW-50REM CL 1250mm x 1500mm (H) 1478mm x 1728mm 149 kg 1.88m2
UHW-50REM 1000mm x 1750mm (H) 1228mm x 1978mm 190 kg 1.75m2
UHW-50REM CL 1000mm x 1750mm (H) 1228mm x 1978mm 201 kg 1.75m2
USS-50REM Min 760mm x Consult UK Office for sizing *
USS-50REM CL Min 760mm x Consult UK Office for sizing *
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:03 Page 17
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com18
Type UGEW-50REM
TYPE UGEW-50REM - Single Leaf 90°Electric actuation for remote opening & closing, the UGEW-50REM offers a natural daylight option withpolycarbonate cover to maximise light transmission whilst minimising solar heat gain.
Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the cover shall be through a 24VDC battery backed control system that will open the cover to the fire open position within 60 seconds and be capable of closing the cover.
Operation of the cover shall not be affected by temperature.
Entire vent shall be weathertight with fully welded corner joints on cover and curb.
Cover: Aluminium extrusion with built in drainage channel and clear polycarbonate double skin dome. Cover shall have a heavy extruded EPDM rubber gasket that is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip®
flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place.
Curb insulation: Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m2K.
Operating Two 24VDC linear actuators capable of opening the cover to the mechanism: fire open position of 90°.
Hardware: Heavy pintle hinges shall be provided.
Curb mounted junction box with a terminal block enclosed for power cable connection.
Finishes: Factory finish shall be mill finish aluminium.
Controls: See page 22
Options: See page 24
SPECIFICATIONSThe smoke vent shall be single leaf and provide 1.0m2 clear vent area. The smoke vent shall be pre-assembled from the manufacturer.
Smoke Vent - Translucent
STANDARD SIZES & WEIGHTS - Translucent - Single Leaf 90°
CL - Curb Liner Special sizes available on request
Bilco’sexclusive
YEARWARRANTY
10
Type Size - clear internal dimensions Overall Dimensions Weight Clear Vent Area
UGEW-50REM 1000mm x 1000mm 1228mm x 1228mm 111 kg 1.m2
UGEW-50REM CL 1000mm x 1000mm 1228mm x 1228mm 119 kg 1.m2
UGSS-50REM Consult UK Office for sizing
UGSS-50REM CL Consult UK Office for sizing
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:03 Page 18
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Type UFW-LVREM
SPECIFICATIONSProduct provides natural daylight and energy efficiency while minimizing solar heat gain. Product features aluminium construction and a virtually indestructiblepolycarbonate cover. The smoke vent shall be double leaf and provide 1.5m2 clear vent area. The smoke vent shall be pre-assembled from the manufacturer.
Smoke Vent - Translucent
STANDARD SIZES & WEIGHTS - Translucent - Double Leaf 90°
19
REM LUMIVENT® - Double Leaf 90° Electric actuation for remote opening & closing, the Lumivent® provides the security and value of anautomatic smoke vent with the added benefits of a skylight.
Type Size - clear internal dimensions Overall Dimensions Weight Clear Vent Area
UFW-LVREM 1250mm x 1250mm 1478mm x 1478mm 113 kg 1.5m2
UFW-LVREM CL 1250mm x 1250mm 1478mm x 1478mm 123 kg 1.5m2
Bilco’sexclusive
YEARWARRANTY
10
Performance Covers shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the covers shall be through a 24VDC battery backed control system that will open the covers to the fire open position within 60 seconds and be capable of closing the covers.
Operation of the covers shall not be affected by temperature.
Entire vent shall be weathertight with fully welded corner joints on covers and curb.
Covers: Shall be constructed with a translucent multi-wall polycarbonate sheet framed with rigid extruded aluminium and coated for UV resistance. Covers shall slope 4:12.
Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip® flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place. There shall be a fixed central drip channel through the centre section of the curb.
Curb insulation: Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m2K.
Operating Two 24VDC linear actuators per cover (four actuators total) mechanism: capable of opening the cover to the fire open position of 90°.
Hardware: Heavy pintle hinges shall be provided.
Curb mounted junction box (2 no.) with terminal blocks enclosed for power cable connection.
Finishes: Factory finish shall be mill finish aluminium.
Controls: See page 22
Options: See page 24
CL - Curb Liner Special sizes available on request
Features a multi-wallpolycarbonate coverdesign that resists UVdegradation and offerssuperior insulationperformance comparedto traditional domes
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:03 Page 19
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com20
TYPE UD-50REM - Double Leaf 90°REM smoke ventilator, electric actuation for remote opening & closing, features aluminium constructionand can be fabricated to just about any size to meet your unique venting requirements.
Smoke Vent - Specials
SPECIFICATIONSThe smoke vent shall be double leaf and provide ____m2 clear vent area. The smoke vent shall be pre-assembled from the manufacturer.
Type Size - Overall Weight Clearclear internal dimensions Dimensions Vent Area
UD-50REM Consult UK Office
STANDARD SIZES & WEIGHTS - Double Leaf 90°
Type UD-50REM
Performance Covers shall be reinforced to support a minimum live load of characteristics: 195 kg/m2 with a maximum deflection of 1/150th of the span or
97 kg/m2 wind uplift.
Operation of the covers shall be through a 24VDC battery backed control system that will open the covers to the fire open position within 60 seconds and be capable of closing the covers.
Operation of the covers shall not be affected by temperature.
Entire vent shall be weathertight with fully welded corner joints on covers and curb.
Covers: Shall be 2.3mm aluminium with a 100mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket that is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb.
Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m2K. Insulation shall be fully covered and protected by
an aluminium liner.
Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip® flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place. There shall be a fixed central drip channel through the centre section of the curb.
Curb insulation: Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m2K.
Operating Two 24VDC linear actuators per cover (four actuators total) mechanism: capable of opening the cover to the fire open position of
90 degrees.
Hardware: Heavy pintle hinges shall be provided. Curb mounted junction box (2 no.) with terminal blocks enclosed for power cable connection.
Finishes: Factory finish shall be mill finish aluminium.
Controls: See page 22
Options: See page 24
Bilco’sexclusive
YEARWARRANTY
10
*Springs included on larger sizes
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:03 Page 20
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com 21
Smoke Vent - Acoustic
STANDARD SIZES & WEIGHTS
Type ACDSH
Performance: Vent(s) shall be UL listed.Characteristics: Covers shall be reinforced to support a minimum live load of
40 psf (195 kg/m2) with a maximum deflection of 1/150th of the span or 90 psf (439 kg/m2) wind uplift.Corrosion resistant gas springs shall open the vent covers simultaneously when latch is manually released or when heat breaks the UL listed fusible link. Opening shall be in a controlled manner to avoid damage to surrounding roof surfaces.Entire roof fire vent shall be weathertight with fully welded corner joints on cover and curb.Latch mechanisms shall hold the covers in the closed position without overstressing the fusible link and withstand 90 psf (439 kg/m2) wind uplift forces acting on the cover.
Latch operation: When heat parts the UL listed fusible link, the latch shall release instantaneously, allowing vent covers to open. The latch shall be designed for easy resetting, after a fire or test, so that the covers cannot be latched closed unless the mechanism has been reset properly. Manufacturer shall provide instructions for resetting the latch with each unit.
Transmission Vent(s) shall carry STC-46 sound rating.Sound Rating:Covers: 14 gauge (2mm) paint bond G-90 galvanized steel with a
5" (127mm) beaded flange with formed reinforcing members.Gasket: PVC gaskets shall be permanently adhered to the underside of
the covers and on top of the curb.
Type Size - Overall Weightclear internal dimensions Dimensions
ACDSH4848 1220mm x 1220mm 1398mm x 1398mm 363 kg
ACDSH4872 1220mm x 1830mm (H) 1398mm x 2008mm 426 kg
ACDSH4890 1220mm x 2290mm (H) 1398mm x 2468mm 533 kg
ACDSH4896 1220mm x 2440mm (H) 1398mm x 2618mm 558 kg
ACDSH6060 1520mm x 1520mm 1698mm x 1698mm 528 kg
ACDSH6096 1520mm x 2440mm (H) 1698mm x 2618mm 701 kg
ACDSH66144* 1680mm x 3660mm (H) 1858mm x 3838mm 1032 kg
ACDSH7272 1830mm x 1830mm 2008mm x 2008mm 685 kg
(H) - Hinge Side *This size has four covers
TYPE ACDSH - Double Leaf 90° Mechanically operated smoke vents. Ideal for concert halls, theatres, casinos, sporting arenas andother applications.
SPECIFICATIONSFurnish and install where indicated on plans metal fire vent Type ACDSH, size [insert: width (______) x length (______) ]. Length denotes hinge side. The roof fire vent shallbe double leaf. The roof fire vent shall be pre-assembled from the manufacturer.
Cover Fibreglass of 3" (76mm) in thickness, fully covered and protectedinsulation: by a 14 gauge (2mm) paint bond G-90 galvanized steel liner. Curb: 12" (305mm) in height and of 14 gauge (2mm) paint bond G-90
galvanized with a fixed centre channel. Curb shall be formed with a 5" (127mm) flange with 7/16" (11mm) holes provided for securing to roof deck. Curb shall be equipped with integral metal capflashing of the same gauge and material as the curb and feature the Bil-Clip® flashing system, including stamped tabs, 6" (153mm) on centre, to be bent inward to hold single-ply roofing membrane securely in place.
Curb insulation: 3" (76mm) fibreglass insulation, fully enclosed by a 14 gauge (2mm) paint bond G-90 galvanized steel liner.
Lifting Corrosion resistant gas springs open covers automatically mechanisms: against a 10 lb/ft2 (49Kg/m2) snow/wind load. Gas springs shall
have built in dampers to assure a controlled rate of opening and automatically lock the covers in the full open position. A release mechanism shall be provided to allow the covers to be closed.
Latch Shall be the BILCO Thermolatch® II positive hold/release mechanism: mechanism with a separate latching point for each cover
controlled by a single UL listed 165°F (74°C) fusible link. Fusible link shall be curb mounted on a non-hinged end to allow the latching mechanism to be easily reset from the roof level.
Hardware: Corrosion resistant gas springs and hot dip galvanized steel stop cables. All other hardware is zinc plated/chromate sealed.
Finish: Factory finish shall be alkyd base red oxide primer.
Options: See page 24
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:03 Page 21
MCPDesigned toallow the FireOfficer tomanuallyoveride thesmoke controlsystem througha user friendlyinterface. Design includes an openbutton and a close/reset button,which are accessed by lifting theclear front door. The unit isequipped with a tamper evident tie. 1RPREM-02
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Control Options
22
Bilco controls and accessories are designed to workeffectively with the range of natural smoke ventilators androof hatches. The OS2 control unit can be a stand-alonemanagement system - in it's own right, or it can be integratedinto a fully networked fire alarm or BMS system. In the eventof a fire, if the mains electrical supply to the building is cut theOS2 offers a failsafe option as it incorporates a backupbattery system to ensure the natural smoke vents will stillopen. Special control units for unique applications can also bemanufactured.
Other control accessories are available to independently openand close access equipment in non-emergency situations forexample for roof inspection and maintenance, as well asmaking it easier to utilize the roof space for plant andrecreational use. There are a number of security accessoriesavailable and options for comfort ventilation. Indeed, with thegrowing demand for buildings to be sustainable, energyefficient and environmentally friendly, a building that canventilate solar heat gains in the summer and retain heat in thewinter is vitally important. Controls such as thermostats andrain sensors can for example, moderate a building 'over-heating' during the day, as well as providing additional revenuesaving benefits in terms of reducing the use of energy hungryH&V equipment.
Junction boxFitted asstandard to allsmoke ventsready for wiring.Meets IP55
Control panel The OS2 control unit can be astandalone management system or it can be integrated into a fullynetworked fire alarm or BMSsystem.OS2 accepts a supply of 230V AC50/60 Hz from a 3A fused un-switched spur and has a currentrating of 2A. Output is 24V DC 2-Channels. Combined outputmust not exceed 8A. Intermittent -6mins in any 1 hour; 5Acontinuous. The backup battery modulecomprises 2x12V DC which has2.2Ah sealed lead-acid batteries.1RPREM-09
Control panel kitComprises-control panel,fireman’s switch(MCP) andsmoke detector1RPREM-01
Typical smokevent
SMOKEVENTS
OPEN CLOSE / RESET
SMOKEVENTS
OPEN CLOSE / RESET
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:03 Page 22
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com 23
The heart of the system
Smoke detector Non-latching &optical, withflashing LED 1RPREM-03
Rain sensor robust & costeffective 1RPREM-15
BMS ExternalConnections (eg. alarm &ventilationsystems)
Auto/manualcontrol switch. To be used inconjunction withthermostatand/or rainsensor.Stainless steelface plate,designed to beused as a 2position switch1RPREM-07
Open/close smokevent switch.Stainless steel faceplate, designed tobe used as a keyedor paddle switch1RPREM-08(keyed)1RPREM-08A(paddle)
Open/closeswitch. 10 amp durablewhite plasticsprung switch. 1RPREM-10
Weather proofopen/close switch.Made from steelthe keyed switchis sprung tocentre and cannotbe operated without the securitykey.1RPREM-11
230V Fused Spur
Volt free contact from fire alarm
Network in
Network out
ThermostatIndustrystandard 10° to 30°crange1RPREM-04
MCPWith breakglass 1RPREM-21
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:03 Page 23
OptionsRoof Access Hatches & Automatic Smoke Vents
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com24
PAINT FINISHES Common options include polyester powdercoating, anodizing aluminium as well as Tnemec®
finishes. Stock items can be polyester powdercoated to any standard RAL or BS colour within2-3 weeks.
CURB OPTIONS Curb Liner Metal insulation liner of the same materials as thecurb and capflashing. Ideal for applications whereaggressive adhesives or torch applied weatherproofing systems are being used.
Built-in LouversUseful for reducing condensation in buildings orfor air displacement in lift shafts.
Flanged Apron DesignA ‘top-hat’ design which makes installation veryeasy and virtually eliminates the problems of waterproofing on the roof. Ideal for situations where theroofing material is applied prior to the hatch orvent arriving on-site.
Fully Enclosed CurbInsulation liner of the same materials as the curb,which replaces the capflashing. Used with hotapplied systems or where the hatch is weldeddirectly to the roofing panel.
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:03 Page 24
EXPLOSION RELIEF SMOKEVENTS Bilco automatic smoke vents may also beequipped to operate as explosion vents or ascombination fire/explosion vents. The explosionrelease mechanism is preset and factory-tested torelease at between 122kg/m2 and 146kg/m2 ofpressure on the underside of the covers.
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Options
25
SECURITY OPTIONS Keyed Cylinder Locks Provide keyed exterior access and are available witheither keyed or turn knob interior access. Idealsecurity enhancement for many applications. Foradded security and weathertightness, the lockcylinder is accessed from the exterior through agasketed, threaded deck plate.
Detention Locks Provide keyed interior and exterior access and areideal for prisons and other buildings requiring amaximum level of security. For added security andweathertightness, the lock is accessed from theexterior through a gasketed, threaded deckplate.Bilco roof hatches can be prepared for fieldinstallation of many leading lock brands.
Emergency EgressBilco roof hatches can be supplied with a paniclatch for rapid egress in an emergency situation.Available with keyed exterior access.
STAINLESS STEEL HARDWARE Installation in highly corrosive environments, Type 316stainless steel hardware, including slam latch andlifting mechanism assemblies; hold-open arms andguides; all brackets, hinges, pins, and fasteners arestandard on J-AL, JD-AL, J-ALH20 and JD-ALH20.
SECURITY GLAZING Allows personnel to visibly scan a secure areabefore entering or exiting a roof area. Glazing isavailable in ballistic ratings.
77969 Revised - pages 14-25:BLC366 UK CATALOG 29/2/12 17:03 Page 25
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Floor Doors
26
Typical Applications
Airports
Distribution Depots
Factories
Hospitals
Manufacturing Facilities
Office Buildings
Ports
Prisons
Retail Centres
Schools
Sewage Treatment Works
Telecommunications Vaults
Utilities
Warehouses
Water/Waste Treatment Works
Structurallyreinforcedcover.Withstands alive load of1464kg/m2 ormore
EXTERIOR • INTERIOR • FIRE RATEDBilco pit and floor doors are available in a wide range of sizes andconfigurations to meet virtually any floor access situation-exterior &interior in aluminium or steel. They range from small interior floordoors complete with insets for carpets and tiles to reinforced doorsfor areas of heavy traffic or high security. Customised designs arealso available which can feature security options, motorisedoperation, a range of finishes and safety aids.
DRAINAGE DOORSConstructed for use in exterior applications or in those situationswhere there is concern of water or other liquids entering the accessopening. These doors are supplied with a threaded drain couplingfully welded to the channel frame for connection to a dry or wet wellin the field.
NON-DRAINAGE DOORSGenerally for interior use or exterior applications where water orliquid infiltration is not a concern. Some models are designed toaccept a wide variety of flooring materials, allowing them to blendinto virtually any building environment.
FIRE DOORSOne and two hour fire rated doors with a choice of diamond patterncover or 25mm pan for matching floor finishes.
Key Features & Benefits
Engineered lift assistance forsmooth, easy door operation,regardless of cover size andweight
Automatic hold-open arm thatlocks the cover in the openposition to ensure safe egress
Even the largest door weighinganything up to 500kg can beeasily opened by one personthanks to Bilco's uniquecounterbalance spring system.
Type 316 stainless steel slamlock to prevent unauthorizedaccess
Constructed with corrosionresistant materials andhardware
Automaticallylocks in thevertical/openposition
Type 316Stainlesssteel slamlock
Cover does not protrude into thechannel frame
Unique counter opposing springsystem means that all Bilcodoors meet Manual HandlingRegulations
6mm aluminium diamond platecover
Type J-AL door shown
77969 Revised - pages 26-35:BLC366 UK CATALOG 29/2/12 17:04 Page 26
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com 27
Engineered excellence for horizontal access!
Versatile Anchor Tabs for addedsupport
Special finishes available
All hardwarecorrosionresistant
Top-sideRemovablesquare keyhandle
Heavy-dutyhinges andopeningsystemprotectedfrom theelements
Top-side - Waterdrainage channelwith drainageoutlet
Underside -38mm threadeddrain coupling forpipe connection
ContinuousEPDM debrisgasket
Lift assisted counter-balanced cover. Liftingmechanism comprisesreinforced Type 316stainless steel springs and tubes
77969 Revised - pages 26-35:BLC366 UK CATALOG 29/2/12 17:04 Page 27
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Type J-AL
Drainage Door
28
TYPE J-AL & JD-AL Aluminium - Single or Double LeafIdeal for most corrosive environments. Single or double leaf covers are constructed of 6mm diamondpattern plate and reinforced for a 1464 kg/m2 live load. Features anti-corrosion hardware, standarddebris gasket, and a versatile anchoring system for ease of installation.
STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight
J-1AL 610mm x 610mm 762mm x 762mm 30 kg
J-2AL 760mm x 760mm 912mm x 912mm 40 kg
J-3AL 915mm x 760mm (H) 1067mm x 912mm 44 kg
J-4AL 915mm x 915mm 1067mm x 1067mm 49 kg
J-5AL 1065mm x 1065mm 1217mm x 1217mm 61 kg
JD-1AL 1220mm x 760mm (H) 1372mm x 912mm 66 kg
JD-2AL 1220mm x 1220mm 1372mm x 1372mm 79 kg
JD-3AL 1220mm x 1830mm (H) 1372mm x 1982mm 106 kg
JD-4AL 1525mm x 1525mm 1677mm x 1677mm 109 kg
Debris Gasket Adjustable Anchor Tabs
Features on all J/JD aluminium doors include
Models with "D" in the Model Type indicate double leaf configuration (H) - Hinge Side
Material: Cover and frame are 6.3mm aluminium.
Cover: Diamond-pattern tread plate reinforced for 1464 kg/m2 live load.
Frame: Extruded aluminium channel frame with bent down anchor tabs around the perimeter. A 38mm drain coupling is welded under the frame for a pipe connection to a dry well or disposal system.
Gasket: EPDM gasket mechanically attached to the frame reduces the amount of dirt and debris that may enter the channel frame.
Hinges: Type 316 stainless steel hinges.
Latch: Type 316 stainless steel slam lock with fixed interior handle and removable exterior turn/lift handle. Latch release is protected by a flush, gasketed, removable screw plug.
Lift Assistance: Compression spring operators enclosed in telescopic tubes. Automatic hold-open.
Finish: Mill finish aluminium with a bituminous coating applied to the exterior of the frame.
Hardware: All hardware stainless steel.
Options: See page 34
SPECIFICATIONS
77969 Revised - pages 26-35:BLC366 UK CATALOG 29/2/12 17:04 Page 28
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
TYPE J-AL H20 & JD-AL H20 Aluminium - Single or Double LeafDesigned to withstand vehicular traffic in off-street locations. Single or double leaf covers are constructedof 6mm diamond pattern plate and reinforced for AASHTO H-20 wheel loading (14,500 kg. axle load).With all the same features as the Type J-AL, this door is also ideal for most corrosive environments.
Drainage Door
Type J-AL H20
29
STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight
J-1AL H20 610mm x 610mm 762mm x 864mm 55 kg
J-2AL H20 760mm x 760mm 912mm x 1014mm 64 kg
J-3AL H20 915mm x 760mm (H) 1067mm x 1014mm 81 kg
J-4AL H20 915mm x 915mm 1067mm x 1169mm 87 kg
J-5AL H20 1065mm x 1065mm 1217mm x 1319mm 111 kg
JD-1AL H20 1220mm x 760mm (H) 1372mm x 1014mm 91 kg
JD-2AL H20 1220mm x 1220mm 1372mm x 1474mm 132 kg
JD-3AL H20 1220mm x 1830mm (H) 1372mm x 2084mm 226 kg
JD-4AL H20 1525mm x 1525mm 1677mm x 1779mm 207 kg
Debris Gasket Adjustable Anchor Tabs
Features on all J/JD aluminium doors include
PerformanceDesigned to withstand H-20 wheel loadings suitable for use in off-street locations where not subject tohigh density traffic
Models with "D" in the Model Type indicate double leaf configuration (H) - Hinge Side
SPECIFICATIONSMaterial: Cover and frame are 6.3mm aluminium.
Cover: Diamond-pattern tread plate reinforced for H-20 wheel loading. Designed for installation in off-street locations where the door is not subjected to high density, fast moving traffic. Structural calculations available upon request.
Frame: Extruded aluminium channel frame with bent down anchor tabs around the perimeter. A 38mm drain coupling is welded under the frame for a pipe connection to a dry well or disposal system.
Gasket: EPDM gasket mechanically attached to the frame reduces the amount of dirt and debris that may enter the channel frame.
Hinges: Type 316 stainless steel hinge pins.
Latch: Type 316 stainless steel slam lock with fixed interior handle and removable exterior turn/lift handle. Latch release is protected by a flush, gasketed, removable screw plug.
Lift Assistance: Compression spring operators enclosed in telescopic tubes. Automatic hold-open arm.
Finish: Mill finish aluminium with a bituminous coating applied to the exterior of the frame.
Hardware: All hardware stainless steel.
Options: See page 34
77969 Revised - pages 26-35:BLC366 UK CATALOG 29/2/12 17:04 Page 29
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Type K-1
TYPE K & KD Aluminium - Single or Double LeafSingle or double leaf covers are constructed of 6mm diamond pattern plate and reinforced for a732 kg/m2 live load. Features zinc plated and chromate sealed hardware, concealed hinges, andthe T-CAM® lifting system for ease of operation.
Material: Cover and frame are 6mm aluminium.
Cover: Diamond-pattern tread plate reinforced for 732 kg/m2 live load.
Frame: Extruded aluminium angle frame with strap anchors bolted around the perimeter.
Hinges: Cast steel cam-action hinges that are concealed from the exterior of the door.
Latch: Type 316 stainless steel slam lock with fixed interior handle and removable exterior turn/lift handle.
Lift Assistance: Torsion bars that pivot on cam-action hinges. Automatic hold-open arm with grip handle release.
Finish: Mill finish aluminium with a bituminous coating applied to the exterior of the frame.
Hardware: Zinc plated/chromate sealed.
Options: See page 34
SPECIFICATIONS
Non-Drainage Door
STANDARD SIZES & WEIGHTS
30
Type Size - clear internal dimensions Overall Dimensions Weight
K-1 610mm x 610mm 832mm x 832mm 23 kg
K-2 760mm x 760mm 982mm x 982mm 30 kg
K-3 915mm x 760mm (H) 1137mm x 982mm 35 kg
K-4 915mm x 915mm 1137mm x 1137mm 39 kg
K-5 1065mm x 1065mm 1287mm x 1287mm 50 kg
KD-2 1220mm x 1220mm 1442mm x 1442mm 69 kg
KD-3 1220mm x 1830mm (H) 1442mm x 2052mm 97 kg
KD-4 1525mm x 1525mm 1747mm x 1747mm 101 kgModels with "D" in the Model Type indicate double leaf configuration (H) - Hinge Side
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 26-35:BLC366 UK CATALOG 29/2/12 17:04 Page 30
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Non-Drainage Door
Models with "D" in the Model Type indicate double leaf configuration (H) - Hinge Side Note: Option available with drain coupling.
Type TER-1
Material: Cover and frame are 6mm aluminium.
Cover: Smooth plate reinforced for 732 kg/m2 live load. Cover designed with 25mm fillable pan for field installation of architectural flooring material (specify flooring material including type, thickness, and weight).
Frame: Extruded aluminium frame with built in anchor flange around the perimeter.
Hinges: Continuous heavy-duty Type 316 stainless steel hinge.
Latch: Type 316 stainless steel slam lock with fixed interior handle and removable exterior turn/lift handle. Latch release is protected by a flush, gasketed, removable screw plug.
Lift Assistance: Compression spring operators enclosed in telescopic tubes. Automatic hold-open arm with grip handle release.
Finish: Mill finish aluminium with a bituminous coating applied to the exterior of the frame.
Hardware: Engineered composite compression spring tubes. Springs shall be manufactured from steel and packaged in grease for corrosion resistance. Type 316 stainless steel hinges. All other hardware is zinc plated/chromate sealed.
Options: See page 34
31
SPECIFICATIONS
TYPE TER & TRD Aluminium - Single or Double Leaf - Accepts Architectural Flooring MaterialThese single and double leaf doors are designed with a pan cover to accept a variety of flooringmaterials up to 25mm in thickness. Each door is spring balanced at the factory to ensure smooth, easyoperation upon installation of the specified flooring material in the field.
STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight
TER-1 610mm x 610mm 814mm x 814mm 45 kg
TER-2 760mm x 760mm 964mm x 964mm 50 kg
TER-3 915mm x 760mm (H) 1119mm x 964mm 54 kg
TER-4 915mm x 915mm 1119mm x 1119mm 59 kg
TER-5 1065mm x 1065mm 1269mm x 1269mm 75 kg
TRD-2 1220mm x 1220mm 1424mm x 1424mm 91 kg
TRD-3 1220mm x 1830mm (H) 1424mm x 2034mm 125 kg
TRD-4 1525mm x 1525mm 1729mm x 1729mm 129 kg
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 26-35:BLC366 UK CATALOG 29/2/12 17:04 Page 31
Material: Cover and frame are 6mm steel. Cover: Diamond pattern plate reinforced for 1464kg/m2 live load. Note: special sizes are available,
but certification only available with a maximum size of 1.14 m2. Intumescent fire coating applied to the underside of the cover.
Frame: Formed channel frame with anchor angle welded around the perimeter. Intumescent fire coating applied on the interior surfaces of the frame.
Hinges: Heavy forged brass hinges with 10mm Type 316 stainless steel hinge pins.Latch: Type 316 stainless steel slam lock with fixed interior handle and removable exterior turn/lift
handle. (Note: can be supplied with self-closing mechanism on sizes 762mm in width and greater when specified, see picture on page 33).
Lift Assistance: Compression spring operators enclosed in telescopic tubes. Automatic hold-open arm with grip handle release. Compression spring operators enclosed in telescopic tubes. Mechanical hold-open system with release button automatically holds the cover in the open position.
Performance Tested in accordance with BS476: Part 22 and approved for a 1-hour fire rating whenRatings: exposed to fire from the underside.Finish: Alkyd base red oxide primer.Hardware: Engineered composite compression spring tubes. Springs shall be manufactured from steel
and packaged in grease for corrosion resistance. All other hardware is zinc/plated and chromate sealed.
Options: See page 34
TYPE JFR Steel - Single Leaf - One Hour Fire-Rated Fire-rated floor doors allow you to specify convenient access through a fire-rated floor withoutjeopardizing fire code compliance. Doors contain flames and limit heat transmission between fire-ratedfloor/ceiling assemblies, and feature fire-proof coating, balanced cover operation, and are available witha specially designed closing mechanism to ensure the door closes automatically when a fire occurs.
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Type JFR-2
SPECIFICATIONS
Fire Doors
32
*Models without BS476: Part 22 certification (H) - Hinge Side
STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight
JFR-1 610mm x 610mm 826mm x 826mm 99 kg
JFR-2 760mm x 760mm 976mm x 976mm 132 kg
JFR-3 915mm x 760mm (H) 1131mm x 976mm 158 kg
JFR-4 915mm x 915mm 1131mm x 1131mm 176 kg
JFR-5 1065mm x 1065mm 1281mm x 1281mm 236 kg
JFR-6 760mm x 1220mm (H) 976mm x 1436mm 190 kg
JFR-7 915mm x 1220mm (H) 1131mm x 1436mm 221 kg
JFR-8* 760mm x 1525mm (H) 976mm x 1741mm 227 kg
JFR-9* 915mm x 1525mm (H) 1131mm x 1741mm 265 kg
JFR-10* 915mm x 1830mm (H) 1131mm x 2046mm 306 kg
PerformanceBS476: Part 22 Certified by for integrity & Chiltern Fire Internationalinsulation
Diamond pattern cover
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 26-35:BLC366 UK CATALOG 29/2/12 17:04 Page 32
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
TYPE FR Aluminium - Single Leaf - Two Hour Fire-Rated Maintains the fire rating of a 2-hour floor/ceiling assembly where access is required between buildingfloors. Features include an optional UL Listed automatic closing system, intumescent fire resistantcoating, and a pan cover designed to accept architectural flooring materials.
Type Size - clear internal dimensions Overall Dimensions Weight
FR-2 740mm x 600mm (H) 962mm x 962mm 123 kg
FR-3 890mm x 600mm (H) 1117mm x 962mm 126 kg
FR-4 890mm x 750mm (H) 1117mm x 1117mm 148 kg
FR-5 1015mm x 910mm (H) 1267mm x 1267mm 167 kg
FR-6 735mm x 1060mm (H) 962mm x 1422mm 149 kgAvailable without self-closing mechanism suffix LC (H) - Hinge Side
STANDARD SIZES & WEIGHTS
Type FR-2
33
Fire Doors
Material: Cover and frame are 6mm aluminium.
Cover: Aluminium plate reinforced for 732 kg/m2 live load. Intumescent fire coating applied to the underside of the cover. Designed with 25mm fillable pan for field installation of architectural flooring material up to 13mm thickness (specify flooring material including type, thickness, and weight). The remaining depth must be filled with concrete to maintain the fire rating of the door assembly (if finish flooring is not desired, the pan must be filled with 25mm of concrete).
Frame: Extruded aluminium frame with built in anchor flange around the perimeter. Intumescent fire coating applied on the interior surfaces of the frame.
Hinges: Continuous heavy-duty Type 316 stainless steel hinge.
Latch: Pneumatic self closing system that automatically closes the door in the event of a fire when heat parts a UL-listed 74˚C fusible link.
Lift Assistance: Compression spring operators enclosed in telescopic tubes. Mechanical hold-open system with release button automatically holds the cover in the open position.
Performance: Tested in accordance with BS476: Part 22, and UL-listed.
Ratings: (File R15197) as having a 2-hour fire rating when exposed to fire from the underside.
Finish: Mill finish aluminium with a bituminous coating applied to the exterior of the frame.
Hardware: Engineered composite compression spring tubes. Springs shall be manufactured from steel and packaged in grease for corrosion resistance. Type 316 stainless steel hinges. All other hardware is zinc plated/chromate sealed.
Options: See page 34
SPECIFICATIONS
New self-closingmechanism
• Simplified design takesup less frame area
• Requires lowermaintenance
• More cost effective• UL Listed
Top side - ready toaccept floor finish.
PerformanceBS476: Part 22 Certified by for integrity & Chiltern Fire Internationalinsulation
Bilco’sexclusive
YEARWARRANTY
10
77969 Revised - pages 26-35:BLC366 UK CATALOG 29/2/12 17:04 Page 33
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com
Floor Door Options
34
Bilco floor doors can include any of the modifications shown below.
Special finishes
Grating panel covers Handrails
Stainless steel hardware
Cylinder lock with a keyway protectedby a threaded cover plug
Panic lock
Recessed padlock hasp covered by aflush hinged lid
Security cover McGuard plugs
STAINLESS STEEL In highly corrosive environments or where there isprolonged exposure to hot water or steam all steeland aluminium doors are available with Type 316stainless steel hardware. Included are all parts ofthe latch and lifting mechanism assemblies; hold-open and guide arm and guides; and all brackets,hinges, pins and fasteners.Note: Standard on J-AL, JD-AL, JAL-H20, JD-ALH20
PAINT FINISHESAll aluminium doors can be supplied with ananodized finish. Other custom finishes areavailable when specified.
LOCKS & LATCHESFour standard lock options are available to addsecurity and prevent unauthorized access. Additional lock options include padlock lugswelded to the exterior door surface, high securitydetention locks and magnetic locks are availableon request.
OTHER OPTIONSHandrails Steel or aluminium gratingSlip resistant coatingsSubmersible pump guide rail bracketsMetal enclosed insulationDrop-in installation modificationsSnow and ice melting cablesElectric motor operation.
77969 Revised - pages 26-35:BLC366 UK CATALOG 29/2/12 17:04 Page 34
SPECIFICATIONSGrating panel(s) shall be fibreglass mouldedin one piece with load bearing bars in bothdirections to allow for use withoutcontinuous side support. Panel shall bedesigned to support a 1464 kg/m2 live loadand be high visibility safety yellow in colour.Torsion rod lift assistance shall be providedfor ease of operation and a hold open armshall also be included to automatically lockthe panel in the fully open 90 degreeposition. A release handle shall be providedto allow the grating panel to be closed andthere shall be a provision for locking thepanel to prevent unauthorized access. Holdopen arm shall be aluminium with a stainlesssteel release handle. All other hardware,including mounting brackets, hinges, torsionrod, padlock loop, andfasteners, shall be Type 316stainless steel. Manufacturershall provide a twenty-fiveyear warranty against defects inmaterial and workmanship.
Tel: 01284 701696 for technical details and drawings: www.bilcouk.com 35
Ideal for safer access and a safer working environment
LADDER UP SAFETY POSTLadderUp® Safety Posts provide easier, safer ladder access through roof hatches, floordoors, and manholes. This telescopic post permanently mounts to the top two rungs ofany fixed ladder, providing a positive hand-hold and enabling the user to enter or exit anopening in an upright and balanced position. Available in four different finishes.
SPECIFICATIONSInstall on fixed ladder(s) below hatch cover(s),LadderUp® safety post Model as manufactured byThe Bilco Company. Device shall be (refer to chartfor material/finish* of model specified). It shall bedesigned with a telescoping tubular section that locksautomatically when fully extended. Upward anddownward movement shall be controlled by astainless steel spring balancing mechanism. Unit shallbe completely assembled with fasteners for securingto the ladder rungs in accordance with themanufacturer’s instructions. * If installation is to be incorrosive atmosphere, specify Model LU-2, LU-3 orLU-4 as conditions warrant.
Bilco’sexclusive
YEARWARRANTY
10Key Features & Benefits
Telescopic design is spring balancedfor ease of operation
Adjustable mounting hardwareaccommodates virtually any ladderrung size or spacing
Automatically locks in the fullyraised position to provide the userwith a firm and steady hand-hold
Handy release lever allows the postto be easily lowered to its retractedposition
Available in four levels of corrosionresistance to provide many years oftrouble free, dependable service.
Handy release lever
Type Description kg
LU-1 BLK Steel/black enamel 11
LU-2 Steel hot dip galv 11
LU-3 Stainless type 304 11
LU-4 Aluminium mill finish 7
STANDARD SIZES & WEIGHTS
Adjustable mounting Automatically locks off
FALL PROTECTION Fall protection grating system is available for J-AL & JD-AL Bilco floor doors. Retrofit kitsare also available for field installation. The fibreglass panel includes lift assistance and anautomatic hold open arm.
Key Features & Benefits
Provides a permanent means of fallprotection under access doors
Fibreglass panel includes liftassistance and an automatic holdopen arm for ease of operation anduser safety
The grating panel consists of25.4mm moulded fibreglass squares
Equipped with stainless steelhardware for maintenance-freeperformance
Grating panel rated for a 1464 kg/m2
live load
Grate operates independently of thecover reinforcing
25 year warranty
Telescopic design
Safety Products
77969 Revised - pages 26-35:BLC366 UK CATALOG 29/2/12 17:04 Page 35
Bilco UK LtdPark Farm Business Centre, Fornham St. GenevieveBury St. Edmunds Suffolk, IP28 6TS, United Kingdom
Tel: +44 (0) 1284 701696 Fax: +44 (0) 1284 702531 E-Mail: bilcouk@bilco.comWeb: www.bilcouk.com
Republic of Ireland/Northern IrelandNewbridge Metal Products, Tougher Business Park
Lewistown, Newbridge, Co. Kildare, Republic of IrelandTel: 00 353 45 431502 Fax: 00 353 45 433747
E-Mail: info@newbridgemetal.ieWeb: www.newbridgemetal.ie
CA
T-U
K 2
012
The Bilco Company reserves the right to make design changes or towithdraw designs and products shown throughout this brochure without
notice as we deem advisable.
©2012 The Bilco Company, New Haven, Connecticut 06505
77969 Revised - Covers:Layout 1 29/2/12 16:51 Page 1
Recommended