View
243
Download
2
Category
Preview:
Citation preview
Lipase Color LiquidA milestone in acutepancreatitis diagnosis
LAB
LAB
Sample - 1 partReagent 1 - 100 partsReagent 2 - 20 parts
Mixing and Lag phase Reading time 120”
Take the 1st reading Take the 2nd reading
0” 180”60”
10
110
100
90
80
70
60
50
40
30
20
10
Identity
30 50 70 11090Lipase Color Liquid Lot#1
Scatter Plot with Fit
Lipas
e C
olor
Liq
uid
Lo
t#2
Linear Fit(-0.30 + 1.00x)
Ref. Description Kit Size17401B* Lipase Color Liquid R1: 4x10 mL; R2: 1x8 mL; Cal: 1x1 mL
17616H* Lipase Color Liquid R1: 4x50 mL; R2: 2x21 mL
16401* Lipase Calibrator 4x1 mL
16150 Clin Chem Control 1 6x5 mL
16250 Clin Chem Control 2 6x5 mL
16550 Clin Chem Cal 4x3 mL
Lot-to-lot comparison
Lipase Color Liquid
Analytical Procedure 580 (570-590) nmTemperature 37° C - Reading Mode Kinetic
Sentinel CH. SpA
Via Robert Koch, 220152 Milan - ItalyPhone: +39 02 3455141Fax: +39 02 34551464sentinel@sentinel.itwww.sentineldiagnostics.com WAT
CHIN
G OV
ER LI
FE
MethodSentinel Diagnostics Lipase Color Liquid was the fi rst method to use a specifi csubstrate 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6-methylresorufi n) ester for thedetermination of Lipase. The use of the long-chain specifi c substrate, which acts assignal amplifi er of the reaction, and the absence of secondary reactions guaran-tees the most reliable and accurate results. Right from the outset, Lipase Color Liquidhas represented a reference point in the routine diagnosis of pancreatic diseases.
Features and AdvantagesLiquid and ready to use reagents.
24 months stability from date of manufacture.
Applications for the most common automatedanalyzers available on request.
Analytical procedure simplicity.
Sensitivity 5 U/L.
Extended dynamic range assured by linearityup to 250 U/L (37°C).
High lot-to-lot consistency.
Reagents fi lled in Universal Vials suitable for AU series, ADVIA series, Roche Modular, Hitachi 917, Dirui series, Mindray BS-800.
Registered under FDA 510 (k) approval number K961179*.
DPL
427
R
EV 0
2 09
/14
In
form
atio
n re
porte
d in
this
docu
men
t may
var
y w
ithou
t not
ice
due
to th
e co
ntin
uous
tech
nolo
gica
l up
date
. NO
T FO
R C
AN
AD
IAN
MA
RKET
.
Sample - 1 partReagent 1 - 100 partsReagent 2 - 20 parts
Mixing and Lag phase Reading time 120”
Take the 1st reading Take the 2nd reading
0” 180”60”
10
110
100
90
80
70
60
50
40
30
20
10
Identity
30 50 70 11090Lipase Color Liquid Lot#1
Scatter Plot with Fit
Lipas
e C
olor
Liq
uid
Lo
t#2
Linear Fit(-0.30 + 1.00x)
Recommended