Sheet No - 28 - Details (11) - Structural Glazing Sloped @ Pharmacy

Preview:

Citation preview

150mm Precast Concrete HollowcoreFloor Slab Has A Span Of 10M

Steel Base Plate To SuppportCHS Above

120mm PIR Rigid InsulationBeing Used On Ground Level

75mm Self Leveling Stuctural Screed

4mm Mormoleum Floor Finish

300mm Cast Insitu Concrete Column

Concrete Infill To SupportDrainage Channel

30mm Sand Blinding BeneathPaving

60x100mm PermeablePaving 1:50 Gradient

Drainage Channel Used To DrainWater Away From Curtain Walling

Hardcore

150mm Corble To Allow SteelBAse Plates To be Fixed To InTerm Supporting Structural Glazing

Machined stainless Steel AngleBrackets Supporting StructuralGlazing

50mm PIR Rigid InsulationUSed To Stop Cold Bridging

Steel PLate Used To DrainWater Away From Glazing

25mm Sloped Structural Glazing2400x2400mm Panel Sizes

Aluminium Plate used to Hold TheGlazing In Place

Aluminium Spider Clamp Used ToSupport The Structural Glazing

Suitable Sealant Used To SealPanels And Make An Airtight Seal

219mm Hot Rolled CHS Secondary Structure ToSupport Structural Glazing

100mm CHS Acting As A Truss Rod SupportingSteel Rod Which Supports Spider Clamp

Steel Rod Acting As A Truss RodWhich Supports Spider Clamp

Steel Plate Pivetted To An 8Degree Slope To Suit Glazing

Trench Heating UsedTo Stop CondensationOccuring On Glazing

Intumescent Seal UsedFor Fire Proporties

150

120

754

300

150

52

15050

25

180

219

25mm Sloped Structural Glazing2400x2400mm Panel Sizes

Aluminium Plate used to Hold TheGlazing In Place

Aluminium Spider Clamp Used ToSupport The Structural Glazing

Suitable Sealant Used To SealPanels And Make An Airtight Seal

4mm ACM Panel Used As ACoping For The Parapet

50mm PIR Rigid Insulation UsedTo Stop Cold Bridging

4mm Aluminium CompositeMaterial Panel RainscreenCladding 600x1200mm Panel Size

Horizontal Steel Z Bracket Used ToSupport The Main Cladding Rail

50mm Horizontal RainscreenCladding Railing System

180mm Secondary Vertical ColdRolled Steel Structure @ 600 Centres

12mm Fibre Cement Particle BoardContinuing Aroung Steel Frame

3 Degree Slope On ACM Coping To AllowIt To Drain Back Onto The Green Roof

Hot Rolled Steel Channel Used ToForm Upstand On The Parapet

180x250mm Hot Rolled Steel Beam ToBe Approved By Structural Engineer

Vapour Barrier

150mm Growing Medium

40mm Drainage Layer/Pots

120mm PIR Rigid Insulation

180X250mm Hot Rolled Steel Purlin ToBe Approved By Structural Engineer

75mm Self Leveling Stuctural Screed

Machined stainless SteelAngle Brackets SupportingStructural Glazing

Hot Rolled Steel Channel Used ToForm Wall Upstand

Removable ACM Panel In Case GlazingNeeds To Be Repaired Or Cleaned

Intumescent Seal Used For FireProporties

Vapour Barrier

219mm Hot Rolled CHS Secondary Structure ToSupport Structural Glazing

100mm CHS Acting As A Truss Rod SupportingSteel Rod Which Supports Spider Clamp

Steel Rod Acting As A Truss RodWhich Supports Spider Clamp

3 Degree Slope On ACM Coping To AllowIt To Drain Back Onto The Green Roof

Protection mat to prevent mechanicaldamage to the waterproofing system

PE Foil Seperator Layer Between TheWaterproofing & Green Roof Components

Gravel Or Stone

203

250

7512

040

150

3Sheet No - 28

Sim

2Sheet No - 29

Sim

1Sheet No - 28

Sim

1Sheet No - 32

Sim

Scale

LECTURER

Drawn by

Date

Project number

As indicated

22/0

4/20

16 2

0:53

:10

Details (11) - Structural GlazingSloped @ Pharmacy

3

15/03/16

Con Mc Evoy

Noel Dunne, Dan O'Sullivan &Mark Duffy

Sheet No - 28

1 : 5Structural Glazing Foundation1

1 : 5Structural Glazing W/ Green Roof3

1 : 20120 ACM Panel Section5

Key PlanNTS

6

3D Perspective Rendered ViewNTS

7

4150

3600

3920

3000

1100mm High GlassBalustrade Provided ForHealth And Safety Reasons

Green Roof

TintedInternalGlass

Intermediate Floor

Circular HollowSections

Ground Floor Level

ACM Rainscreen Cladding

3000x3000mm StructuralGlazing Panels

Basement RaftFoundation

300mm WallBuild Up InBasement

InternalPartitionWall

Section Cut Structural GlazingNTS

4

The Steel Plates And Angled Brackets Protecting And SupportingThe Structural Glazing Are Removable So That In The Event WhereA Panel Is Broken And Needs To Be Replaced It Is Easy To Do So.

This Also Applies To The Top As The Angle Brackets And CladdingPanels Are Removable As To Get Easy Access To Replace TheStrucural Glazing.

Removable BracketsNTS

8Removable Cladding Panel

NTS10

Removable Aluminium BaseCover Panels

NTS9

3D Perspective Rendered ViewNTS

11

Recommended