Upload
vanthuan
View
264
Download
2
Embed Size (px)
Citation preview
Russia
JOINT STOCK COMPANY
“ATOMSTROYEXPORT”
KUDANKULAM NPPUnits 3-6
NPP Coding System
Agreement on KKS codification system appliance in the NPP “Kudankulam” Project in India
Package Number T2
Number of the Document Total Number of Pages Date Revision Number
R01.KK36.0.0.OO.KKS.P002 143 08.2017 0
Document Inventory № File:R01 KK36 0 0 OO KKS P002=e0
Document Control №
Contract Number 77-255/1624000
JOINT STOCK COMPANY “АTOMENERGOPROEKT”
Title of NPP KUDANKULAM NPPUnits 3-6
Title of Package and Document
NPP Coding System
Agreement on KKS codification system appliance in the NPP “Kudankulam” Project in India
Package Number T2
Number of the Document Total Number of Pages
Date Revision Number
R01.KK36.0.0.OO.KKS.P002 143 08.2017 0
Document Inventory № File: R01 KK36 0 0 OO KKS P002=e0
Document Control №
Contract Number 77-255/1624000
Design Chief Engineer Deputy Director for Kudankulam NPP Designing
Director of the Moscow Design Institute
V.V. Kats I.A. Chistozvonov E.B. Mishin Date Signature Date Signature Date Signature
Translation by: Translation checked by:
E.Yu. Babkina V.I. FilatovDate Signature Date Signature
This
doc
umen
t she
ll no
t be
fully
or p
artia
lly re
prin
ted,
cop
ied
and
dist
ribut
ed w
ithou
t per
mis
sion
of
JSC
“A
tom
ener
gopr
oekt
”
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
ANNOTATION
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 2
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
CONTENTS
Definitions............................................................................................................................ 5
List of Abbreviations............................................................................................................ 6
1 Application requirements................................................................................................... 9
1.1 General requirements...................................................................................................... 9
1.2 Basic principles and fields of application......................................................................10
1.3 Procedure of producing................................................................................................. 11
1.4 Procedure of coordination and approval........................................................................11
1.5 Procedure of dictribution............................................................................................... 11
1.6 Responsibility............................................................................................................... 11
2 Subjects to finalize........................................................................................................... 12
3 Requirements agreed upon...............................................................................................14
4 List of codes for process systems, buildings and structures..............................................22
5 list of equipment codes................................................................................................... 101
6 List of codes for equipment parts...................................................................................110
Appendix A Structure of functional-technological code KKS...........................................117
Appendix B Numbering in the equipment code.................................................................118
Appendix C Correlation between the service elevations and grade levels..........................130
Appendix D Principles of cable coding.............................................................................131
Appendix E Coding principle of ULCS video frames........................................................140
Appendix F Principles for coding ventilation system plants and equipment......................141
Distribution list................................................................................................................. 142
Revision list...................................................................................................................... 143
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 3
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
DEFINITIONS
Term Definition
NUCLEAR PLANT Structures and complexes with nuclear reactors, necessary systems, devices, and equipment for generating power in the specified modes and application conditions, located within the limits of a territory determined by the NPP design, with the necessary personnel and documentation; an NPP may also contain fuel and radwaste storage facilities [NP-001-15 “General provisions on NPP safety OPB-88/15”]
NUCLEAR POWER PLANT (NPP) Nuclear power plant intended for production of electric energy [NP-001-15 “General provisions on NPP safety OPB-88/15”]
OUTER CONTAINMENT (UJB) The outer (secondary) shell of the reactor building including its annulus
«KUDANKULAM» NPP Nuclear Power Generating Plant «Kudankulam» consisting of six power Units with VVER - type reactor plants along with all its associated systems to be set up at the Site including Units 1 & 2 under construction and four additional Units. Power unit shall mean a part of the Plant performing its function in the designed scope. A Unit shall comprise one set of reactor plant, one set of turbo-generator system and all related systems necessary for safe and reliable electric power generation [Contract 77-255/1624000]
KKS CLASSIFICATION AND CODING SYSTEM
The system developed by VGB, Germany
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 4
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
LIST OF ABBREVIATIONS
APC automatic power controller;ARSMS automated system of radiation situation monitoring;ACSAPCSBRU-A
automated control system;automated process control system;fast-acting steam dump system with discharge into atmosphere;
BRU-DBRU-K
fast-acting steam dump valve for discharge into deaerator;fast-acting steam dump valve with discharge to turbine condenser;
BRU-SN fast-acting steam dump unit with discharge to auxiliary header;ELHEPSS
essential loads header;emergency power supply system;
CCRCESCMSCMS DCRWSCSCSS
central control room;central engineering storage;control and monitoring system;control, monitoring and diagnostics system;central repair workshops;computer system;control safety system;
CTWEP
chemically treated water;emergency protection;
GISGCB
gas-insulated switchgear; generator circuit breaker;
FAFEFPS TDFRWS
HPH
fuel assembly;fuel element;feed pump set – turbine drivenfresh radioactive waste storage;high pressure heater;
HPC ISCSIAS
high pressure cylinder;initiating safety control system;integrated analysis system;
I&C instrumentation and control system;ICSS initial control safety system;IRG inert radioactive gases;ISH in-house supply header;KKS classification and coding system;
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 5
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
LMS leak monitoring systems;LPCLPH
low pressure cylinder;low pressure heater;
MCR main control room;MCDS monitoring, control and diagnostic system;MS/SR moisture separator / steam reheater;NFME neutron flux monitoring equipment;NFS new fuel storage;NPP nuclear power plant;NONOSOPB
normal operation;normal operation system;general provisions for assurance of safety at nuclear power stations;
OSPP
open switchgear;preventive protection;
PHRS passive heat removal system;PRZ pressurizer;PSV pilot operated safety valve;PTCPTLRBRCRCP
personnel training center;power transmission lines;reactor building (compartment);reactor containment;reactor coolant pump;
RCPS reactor coolant pump set;RCPS STD system for technical diagnosing of RCPS;RPV reactor pressure vessel;RCD remote Control DeviceRWRWTSRWSBSCSSgSG
radioactive wastes;radioactive water treatment;solid radioactive wastesspecial building;safety control system;switchgear;steam generator;
SGCLSGVHCSRWSSS
steam generator control level;steam generator vapor humidity control;spent radioactive waste storage;safety system;
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 6
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
SVTDPTPTS
safety valves;turbine-driven feed water pump set;standard computerized automation facilities;
UDPULCSUSH
unit demineralizing plant.upper level control system.unified Set of Hardware
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 7
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
1 APPLICATION REQUIREMENTS
1.1 GENERAL REQUIREMENTS
1.1.1 For coding buildings, structures, systems, equipment and its components in NPP “Kudankulam” project there is applied a unified classification and coding system KKS developed by technical committee of industrialists association VGB (Germany) VGB.
1.1.2 The KKS classification and codification system is a universal system that enables it to identify any process system, facility, structure or component in the process of designing, erection and operation of a power plant.
1.1.3 The «Agreement on KKS codification system appliance in the NPP “Kudankulam” Project in India» (hereinafter the Agreement) regulates activity of organizations involved in development of NPP “Kudankulam” project as for application of the classification and coding system KKS. The agreement has been developed in compliance with requirements of standard regulations for KKS application.
1.1.4 The standard regulations for KKS application are stipulated in KKS documents:
«Guidelines for KKS Application», 4-th version of 1995;
«KKS Application Commentaries. Part A General», version of 1988;
«KKS Application Commentaries. Part B Engineering Discipline-Specific. Part B1 Identification in Mechanical Engineering», version of 1988;
«KKS Application Commentaries. Part B Engineering Discipline-Specific. Part B2 Identification in Civil Engineering», version of 1988;
KKS Application Commentaries. Part B Engineering Discipline-Specific. Part B3 Identification in Electrical and Instrumentation and Control Engineering», version of 1988;
«Usage Instructions. Part B Engineering Discipline-Specific Application Commentaries. Part B4 Identification of I&C Tasks and Functions in Process Systems and of Functions in I&C Systems», version of 1993;
«KKS Keys», version of 1991;
1.1.5 Structure of functional-technological code KKS is addressed in appendix А.
1.1.6 Section 3 of this document «Requirements agreed upon» contains a list of non-regulated by KKS provisions, which is a subject of agreement. This list may be extended if new provisions appeared in the course of work.
1.1.7 Since the full number of process systems, buildings and structures can be known and coded only when the detailed design is finalized this document presents the list of codes adopted at the stage of first-period design works.
The full list of codes for process systems, buildings and structures shall be issued at the working documentation stage.
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 8
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
1.1.8 To meet any additional identification requirements, the KKS codes, or parts thereof, can be combined with other coding systems. This shall be reported to the Customer and all participants of the project in writing.
1.2 BASIC PRINCIPLES AND FIELDS OF APPLICATION
1.2.1 Fields of KKS Application
1.2.1.1 The KKS system is used to identify facilities (process systems), structures, equipment, components and devices in accordance with their purpose, location and installation. This system is utilized in designing, construction, operation and maintenance of power engineering facilities as well as in communication with Regulatory Authorities.
Buildings, structures, functional process systems and equipment, including stationary tools at NPP “Kudankulam” are subject to coding. Boundaries of coding for NPP components are specified by the developer of the documentation.
1.2.1.2 KKS elements are applied to coding the documentation. The Documentation is coded in accordance with R01.KK36.0.0.QA.WI.P002 “Manual on documentation coding of NPP “Kudankulam” Project”.
1.2.2 Basic Principles of KKS
1.2.2.1 KKS is based on the following principles:
uniform identification for all types of power stations and any related processes;
sufficient capacity and detailing for identification of all systems, components, structures and areas;
extension capacity to incorporate new technologies;
uniform identification during designing, erection, operation, maintenance and decommissioning;
applicability in mechanical engineering, civil engineering, electrical engineering, I & C and other disciplines with the possibility to identify the items that belong to these disciplines as well as places of installation and location;
consideration of national and international standards;
language-unbiased coding to ensure the possibility of international application;
application of computer data processing.
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 9
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
1.3 PROCEDURE OF PRODUCING
1.3.1 This document must be revised in the following cases:
- at the request of the Indian Customer or the Customer (JSC “Atomstroyeksport”);
- on the decision of the General Designer if there is a significant amount of changes that have to be introduced into the document.
1.3.2 Each of participants of Kudankulam Project may put forward a proposal about altering or complementing the document and send it to the General Designer for approval.
1.3.3Changes are incorporated by the General Designer as per a duly established procedure.
1.4 PROCEDURE OF COORDINATION AND APPROVAL1.4.1 This document is subject to coordination with main participants of NPP
«Kudankulam» Project. The General Designer of the Power Plant specifies the list of main participants coordinating the document.
1.4.2 The document is considered coordinated if no reply is available from the project participants for 20 working days from receipt of the official letter about its direction for approval. The fact of receiving the letter is considered the moment of registering incoming letter in the workflow system of the Project participant.
1.4.3 The document is to be revised and a new revision is to be issued after its approval by the Indian Customer.
1.5 PROCEDURE OF DISTRIBUTION1.5.1 The General Designer of the Power Plant sends this document to the Indian
Customer, the Customer (JSC «Аtomstroyexport») and its subcontractors.
1.6 RESPONSIBILITY1.6.1 The General Designer of the Power Plant is responsible for development and
revision of this document.
1.6.2 The Customer (JSC «Аtomstroyexport») and the General Designer of the Power Plant are responsible for providing their subcontractors with the document.
1.6.3 Developer of particular documentation of Kudankulam Project is responsible for accuracy of structure and coding of KKS.
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 10
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
2 SUBJECTS TO FINALIZE
2.1 The conditions of application are strictly and explicitly covered by the KKS system as a whole and only in particular cases general recommendations regarding possible and expedient ways of coding the NPP components are provided. These KKS regulations shall be mutually agreed between all designing participants which ensures the uniformity of the KKS coding system application, to extend the information content of the codes and will ensure unambiguous understanding of the technical documentation by the Principal.
2.2 The list of codes not specified in KKS and being subject to agreement between all the participants of design development is given below.
General conditions
1 Modification of titles (possible only without content changing ).
2 Determination of the numerical system and its direction for all numerical parts of designation.
3 Determination of sector 0 in respect to:
the content;
type of code (application of numerals or characters);
coding order.
4 Determination of code entering method.
5 Application of reserve codes.
Conditions of application of the process-related coding
6 Application of codes for process-related items.
7 Utilization of group F0.
8 Definitions for group FN numbers.
9 Definitions for group AN numbers.
10 Definitions for group A3 numbers.
11 Definitions for group BN numbers.
12 Definitions for signal codes and their application, and specification of subdivisions in the main groups X, Y and Z in sector 3.
13 Coding of mounting hardware in mechanical engineering.
14 Coding of support systems in mechanical engineering.
15 Coding of standard separation methods for media preparation.
16 Coding of civil structures.
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 11
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Conditions of application of coding of structures (board, cabinet, panel)
17 Application of codes for electrical equipment, I&C and automation structures (board, cabinet, panel) coding.
18 Application of group F0 codes for structure coding.
19 Numbering in group FN for structure coding.
20 Coding of the mounting place in the structure.
Conditions of application of location coding
21 Application of code groups for location coding.
22 Application of group F0 for structures coding.
23 Application of group F3.
24 Numbering in group FN for structures coding.
25 Coding of rooms.
26 Coding of separate structures combined with a specific structure.
27 Coding of channels and trestles as connecting facilities.
28 Coding of joint.
29 Principles of cable coding.
30 Coding principle of ULCS video shots.
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 12
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
3 REQUIREMENTS AGREED UPON
List of the KKS regulations
Accepted for the Kudankulam NPP
General conditions
1 Modification of code titles
1.1 It is allowed to modify code titles provided in the code guide (alphabetic index of KKS) without any changes of the content. Such modifications should be approved by the representative of the General Designer of the Power Plant.
The list of codes adopted in the beginning of the design development is given in Section 4 of this Agreement
1.2 The code of buildings (structures) for two power units is given in the Agreement in the separate names of codes of the functional systems applied for two power units (units 3 and 4), for example:
KTN - Active drainage pipework system (traps) of the 30UKC (40UKC) building (free-flow part).
If the documentation is developed only for Unit 3, the KTN code name indicates only the building of Unit 3, namely:
30KTN - «Active drainage pipework system (traps) of the 30UKC building (free-flow part)»;
If the documentation is developed only for Unit 4, the KTN code name indicates only the building of Unit 4, namely:
40KTN - «Active drainage pipework system (traps) of the 40UKC building (free-flow part)
1.3 The separate names of functional system codes used in the Agreement indicate all buildings, to which the specified system applies (sequentially, separated by a comma), for example:
SMT20 – Electric travelling cranes in buildings 00UTF, 00UTH.
In the documentation is developed only for the 00UTF building, the 00SMT20 code name indicates only this building, namely:
00SMT20 - « Electric travelling cranes in buildings 00UTF»;
If the documentation is developed only for the 00UTH building, the 00SMT20 code name indicates only this building, namely: 00SMT20 - « Electric travelling cranes in buildings 00UTH ».
2 Order and direction of numbering in all numerical code sectors
2.1 The numerical numbering increases toward the flow direction (fluid, energy, data). The following rules are observed in this case:- numbering starts anew, if one of the preceding code elements changes;
- numbering can be inseparable or groupwise;
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 13
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
List of the KKS regulations
Accepted for the Kudankulam NPP
- numbering can be effected using wrong counting;
- assigned numerical code characters shall not change in the process of designing;
- all zeroes before a significant digit must be written;
- numbering shall follow some kind of logic which can be different for different parts of the project
3 Regulation on application of sector 0 regarding the content, code type (numbers or characters) and direction of coding
3.1 Sector 0 is for belonging to the unit, common-unit or common-station installations.3.2 Coding of Unit 3 is performed with digital symbol 3.
3.3 Coding of Unit 4 is performed with digital symbol 4.
3.4 Coding of Unit 5 is performed with digital symbol 5.
3.5 Coding of Unit 6 is performed with digital symbol 6.
3.6 Coding of common-unit facilities for Units 3 and 4, Units 5 and 6 is performed with digital symbol «0».
3.7 Coding of common-station facilities (for Units3-6) is performed with digital symbol «0»
4 Code writing 4.1 A code is written in one, two, or three lines, e.g.:- in one line:
30JND20AP001MK01;
40JND20AP002;
30CCA03GW001;
30UMA10AB001;
- in two lines:30JND20 30CCA03 30UMA10 AP001MK01; GW001; AB001;
- in three lines:30JND20 AP001 MK01
4.2 When a code is introduced in a programmer product, the code should be written without spaces in compliance with margins used according to the principle 1 code = 1 record. Software products shall contain neither hyphenations, nor «Alt+Enter» keys combinations. If information is not available in the functional process code group A3, this group is replaced in the SPE and on a paper carrier by a space.
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 14
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
List of the KKS regulations
Accepted for the Kudankulam NPP
5 Application of reserve codes
5.1 Reserve codes may be used:
- upon coordination with the technical committee of Association of Industrialists VGB (such codes are marked in the reference book of KKS codes with words «blocked»);
- upon coordination with the General Designer of Kudankulam NPP (such codes are marked in the reference book of KKS codes with * «free for use»
Functional and process-related codes
6 Application of codes clusters for Process Related identification
6.1 Use of codes clusters is performed in accordance with i.3.1 «Guidelines for KKS Application». Cluster of codes G is applied in accordance with i. 3 of section 2 «Coordinated provisions» of this document. Cluster of codes A3 is applied in case of necessity
7 Application of code F 0 (sector 1)
7.1 The digital group (cluster) F0 uses numbering from 0 to 9. The use of cluster F0 is mandatory:
7.2 For the civil part of the design, the digital cluster F0 is used for denoting the same functional types of buildings and structures.
7.3 The following characters are used in the F0 cluster for the mechanical, electrical, and I&C parts of the design:
7.3.1 the digital symbols 1, 2, 3, 4 are used to denote:- safety system trains and their elements,
- elements used in the trains of the emergency power supply system (EPSS),
- elements that take power supply from the EPSS;
7.3.2 the digital symbol 0 is used to denote:
- elements of normal operation systems,
- elements belonging to the normal-operation auxiliary power supply system,
- NO functional systems,
- Functional safety systems as a whole (for denotation of SS trains see i .7.3.1);
7.3.3 The digital symbol 5 is used to denote elements of heating, ventilation, and air conditioning systems taking power supply from the normal-operation diesel-generator
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 15
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
List of the KKS regulations
Accepted for the Kudankulam NPP
8 Application of code FN (sector 1)
8.1 In digital code FN numbering is used within 00 to 99. Examples of possible numbering for thermal part are given in i.1.3.2.1 «KKS Application Commentaries. Part B Engineering Discipline-Specific. Part B1 Identification in Mechanical Engineering».
When writing references in documents (schedules, main inscriptions in graphic and writing documents, etc.) to codes of functional systems, consisting of several numerals (e.g. MKF10-50; PGB74,78), it is allowed to indicated a code with one numeral only, for example:
- MKF10 code is indicated for MKF10-50 code;
- PGB74 code is indicated for PGB74, 78 code
9 Application of code AN (sector 2)
9.1 The numerical code AN is applied for assigning a number to a structure. The biggest number is 999. The numbering of each group starts from 001. In order to extend the information content of the code the first letter of code AN can be attached to the definite types of items, or to have another meaning. Information on application of groups of numerical data characters of codes AN from 001 to 900 is provided in appendix B “Numbering in Equipment Code”
10 Application of the alphabetic code A3 (sector 2)
10.1 Additional group of the alphabetic codes A3 is used:
- for coding double drive of some piece of equipment;
- for coding several measuring circuits with one sensor;
- for coding phases (A, B, C) in the equipment unit code for electrical devices when execution is in phases;
- for further separation of rooms;
- for further separation of lighting system by applying letters of Latin alphabet:
N – operating lighting system;
E – emergency lighting system;
F – evacuation lighting system
11 Application of code BN (sector 3)
11.1 Numbering of parts of assemblies from 01 to 99. In force are definitions i. 3.1.3. «Guidelines for KKS Application». Examples of BN-numbering are given in i. 3.1.3.2 «KKS Application Commentaries. Part A General»
12 Application of code signals X, Y, Z (sector 3)
12.1 Codes of signals X, Y, Z are applied in accordance with Section 4 of this "Agreement…" Numbering of signals for programmable devices is not limited
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 16
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
List of the KKS regulations
Accepted for the Kudankulam NPP
12a Coding of components in the I&C and electrical circuits (sector 3)
12a.1 “-“symbol is used for coding electrical devices in the component codes (as per KKS).
12a.2 The coding of the electrical devices in the electrical circuits in sector 3 “equipment component” is allowed to be carried out not as per the KKS but in combination with GOST 2.710-81. In this case the code characters between sectors 2 and 3 are divided by “/” symbol , for example:
F1F2F3NN A1A2NNN/ABCNN
code as per KKS (part) code as per GOST 2.710-81 (part)13 Coding of mounting hardware for electrical and I &C systems(sector 2)
13.1 Elements of fixing in thermal systems are encoded in accordance with i. 5.4.3 «Guidelines for KKS Application».
13.2 For indication of elements of fixing in electrical systems and I&C devices there is used code GZ (i.5.6.1 «Guidelines for KKS Application»
14 Coding of support systems for mechanical engineering (sector 1)
14.1 In force are definitions of i. 5.4.3 «Guidelines for KKS Application». Examples of encoding of support systems are given in i. 3.1.1.3 «KKS Application Commentaries. Part B Engineering Discipline-Specific. Part B1 Identification in Mechanical Engineering»
15 Application of the standard code for media preparation and processing systems (sector 1)
15.1 For media preparation and processing systems (main codes G, P and L), for code groups GB, GC, GD, GN, GR, PB, PD, PF, PH, PK and LD the same meaning of F3 code is used:
Code F3 B- filtration, mechanical purification;
D- sediment;
E- acid measuring;
G- evaporation;
F- ion exchange;
H- degassing, de-watering;
J- heating, de-watering;
N- chemicals supply;
P- regeneration and flushing;
Q- softening;
S- sediment compaction (sludge thickening)16 Application of coding for civil structures
16.1 See paras. 21-28
Coding of installation (mounting) points for the electrical and I & C equipment
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 17
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
List of the KKS regulations
Accepted for the Kudankulam NPP
17 Use of cluster of codes for identification of installation site
17.1 The clusters of codes are used in accordance with subsection 3.2 «Guidelines for KKS Application». Cluster of codes G is used in accordance with i. 3 of section 2 «Coordinated provisions» of this document
18 Application of code group F0
18.1 The cluster of codes F0 is used in accordance with i. 7 of «Coordinated provisions» of this document
19 Numbering in cluster FN
19.1 In digital code FN numbering is used within 01 to 99. Examples of possible numbering are given in subsections 5.2 and 5.3 of Special comments to KKS application, part В, section В3
20 Coding of an erection spot in an erection block
20.1 Coding is carried out in accordance with i. 3.2.2 «Guidelines for KKS Application». Examples of coding are given in subsection 5.1 «KKS Application Commentaries. Part B Engineering Discipline-Specific. Part B3 Identification in Electrical and Instrumentation and Control Engineering»
Coding of the arrangement place (buildings, elevations, rooms)
21 Application of code groups for identification of the arrangement place
21.1 The clusters of codes are used in accordance with subsection 3.3 «Guidelines for KKS Application». Cluster of codes G is used in accordance with i. 3 of section 3 «Coordinated provisions» of this document
22 Application of code F0 (sector 1)
22.1 The preliminary code F0 is used in accordance with i. 7 of Section 2 "Agreed Provisions" in this document
23 Application of codes F2, F3
(sector 1)
23.1 Alphabetic designation of codes F2, F3 is taken from the code guide according to the priority purpose of the coded building/ structure
24 Application of sector FN (sector 1)
24.1 Numeration of service elevations for each building and structure is made independently, see appendix C “Correlation between the service elevations and grade levels”
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 18
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
List of the KKS regulations
Accepted for the Kudankulam NPP
25 Coding of rooms (sector 2)
25.1 Rooms are encoded in accordance with i. 3.3.2.1 «Guidelines for KKS Application». Examples of the coding are given in i. 3.2.1.1 «KKS Application Commentaries. Part B Engineering Discipline-Specific. Part B2 Identification in Civil Engineering».
In this case:
direction of numbering should be according to rectangular coordinates;
in cluster of codes A1 - code R or S should be present always ;
numbering of rooms in cluster AN is carried out with three-sign digital symbol.
For shafts and rooms that includes several service elevations a three-digital group coding is used:
3NN – transport shafts;
4NN – cable shafts;
5NN – stair cases;
6NN – elevators;
7NN – reactor cavities;
8NN – process shafts;
9NN – ventilation shafts.
The numbering of FN of sector 1 can be carried out on the lower service elevation where the shaft or room starts or on each service elevation
26 Coding of separate structures combined with a specific structure
26.1 In case of combining buildings and structures possessing their own KKS codes, the combined assignment gets a separate KKS code.
If it is impossible to assign an individual code for these buildings and structures, the code of the top process priority building is assigned to the entire complex. In this case in Section 4 of this "Agreement…" the code should firstly consist of designation of united building and using symbol "/" designation of building, to which this code belongs directly.
For example:
30UJA Reactor building/Internal containmentIn documentation: for the inner containment of the 30UJA building, the full name is used: “Reactor building/Inner containment”;
for the united building, the following name is used: “Reactor building”
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 19
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
List of the KKS regulations
Accepted for the Kudankulam NPP
27 Coding of channels and trestles as connecting structures
27.1 Channels and trestles are coded as per the code of one of the connected buildings/structures depending on the process priority of the building/structure
28 Coding of aggregates of fixing
28.1 Aggregates of fixing are encoded in the aggregate code BQ in accordance with i. 5.4.2. «Guidelines for KKS Application». Digital cluster of signs of the aggregate code BQ is divided in accordance with appendix B
29 Principles of cable coding
29.1 See appendix D
30 Coding principle of ULCS video shots
30.1 See appendix E
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 20
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
4 LIST OF CODES FOR PROCESS SYSTEMS,BUILDINGS AND STRUCTURES
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 21
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
A.. Networks and switchgears
AC. 400 kV gas insulated switchgear and control gear
ACA Bus system I
ACB Bus system II
ACE 400 kV gas-insulated bus duct
ACL 400 kV power transmission line
ACQ 400 kV switch
ACR 400 kV reactor
ACT 400/220 kV autotransformer
AD. 220 kV gas insulated switchgear and control gear
ADA 220 kV bus system I
ADB 220 kV bus system II
ADE 220 kV SFG bus duct
ADL 220 kV power transmission line
ADQ 220 kV switch
AF. Systems at 60 kV and less
AFA Section 0,38 kV (from AFT11)
AFB Section 0,38 kV (from AFT21)
AFT Auxiliary transformers 6/0.4 кV, belonging to power output system
AH. Standby power supply of power output delivery system
AHA Trunk line of standby power supply of common-station load from AHT10
AHT Stand-by transformers 6/0.4 kV of normal operation
AR. Auxiliary low-voltage switchgear, uninterruptible (inverter) power supply of the power output system
ART Inverter of normal common plant system
AT. Installation of storage batteries of power output delivery system
ATA 220 V batteries of normal common plant system
ATL Boost charging & battery charging rectifier of normal common plant system
AU. Control devices, signaling devices, and auxiliary devices
AUA DC distribution board
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 22
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
AUB DC distribution board
AUS Portable system for cable fault detection
B.. Power transmission and auxiliary power supply
BA. Energy removal, generator voltage conductors
BAA Removal from generator, generator voltage conductors
BAB Foundation cells
BAC 24 kV GCB, including chilling installations
BAT Generator transformers, including chilling installations
BAY Control monitoring and relay protection system of electric equipment
BB. 6 kV auxiliary sections and transformers. Normal operation system
BBA 6 kV switchgears for normal operation system (Unit section 1)
BBB 6 kV switchgears for normal operation system (Unit section 2)
BBC 6 kV switchgears for normal operation system (Unit section 3)
BBD 6 kV switchgears for normal operation system (Unit section 4)
BBT 24/6,3-6,3 kV working transformer for power auxiliaries for normal operation system
BBY Control monitoring and relay protection system of electric equipment
BC. Standby power supply section for the common-station load and standby power supply transformers of 6 kV buses. Normal operation system.
BCA 6 kV standby power supply section (network 1)
BCB 6 kV standby power supply section (network 2)
BCC 6 kV standby power supply section (network 3)
BCD 6 kV standby power supply section (network 4)
BCE 6 kV section 1 for common-station load
BCF 6 kV section 2 for the whole plant load
BCG 6 kV section 4 for the whole plant load
BCH 6 kV section 3 for the whole plant load
BCJ 6 kV section for common-station load
BCK 6 kV section for common-station load
BCL 6 kV standby power supply line
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 23
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
BCT 220/6,3-6,3 kV standby and common-station auxiliary transformers
BD. Switchgears 6 kV of emergency power supply system
BDA Emergency power supply system (EPSS) switchgears (safety channel 1)
BDB Emergency power supply system (EPSS) switchgears (safety channel 2)
BDC Emergency power supply 6 kV system (EPSS) switchgears (safety channel 3)
BDD Emergency power supply 6 kV system (EPSS) switchgears (safety channel 4)
BDE Section 1 of emergency power supply (diesel common-station network) of normal operation system
BDF Section 2 of emergency power supply (diesel common-station network) of normal operation system
BDG 6 kV cable assembly of XKA 50 diesel-generator
BDH 6 kV cable assembly of XKA 60 diesel-generator
BDL 6 кV section power supply line of EPSS and 6 kV section power supply line of NOS reliable power supply
BF. 0,4 kV auxiliary unit sections and 6/0,4 kV transformers. Normal operation system
BFA Unit section from BFT11
BFB Unit section from BFT21
BFC Unit section from BFT31
BFD Unit section from BFT41
BFE Unit section from BFT12
BFF Unit section from BFT22
BFG Unit section from BFT32
BFH Unit section from BFT42
BFJ Pressurizer section from BFT13
BFK Pressurizer section from BFT23
BFL Pressurizer section from BFT33
BFM Unit section from BFT41
BFN Lighting section from BFT14
BFP Control and protection system section from BFT24
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 24
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
BFR Control and protection system section from BFT44
BFT 6/0,4 kV auxiliary transformer of Main Building
BFW Lighting section from BFТ34
BG. Sections 0,38 kV and transformers 6/0,4 kV of normal reliable power supply system
BGE Section 0,38 kV from BGT11
BGF Section 0,38 kV from BGT21
BGJ Section 0,38 kV from BGT12
BGK Section 0,38 kV from BGT22
BGN Section 0,38 kV from BGT13
BGP Section 0,38 kV from BGT23
BGT Auxiliary 6/0,4 kV transformer, belonging to normal reliable power supply system
BH. Main standby power supply low-voltage networks 0,38 kV and standby transformers 6/0,4 kV
BHA Standby auxiliary section 0,38 kV from BHT11
BHC Standby auxiliary section 0,38 kV from BHT31
BHD Standby auxiliary section 0,38 kV from BHT43
30BHE Standby auxiliary section 0,38 kV from 30BHT51
40BHE Standby auxiliary section 0,38 kV from 40BHT21
30BHF Standby auxiliary section 0,38 kV from 30BHT61
40BHF Standby auxiliary section 0,38 kV from 40BHT41
40BHG Standby auxiliary section 0,38 kV from 40BHT51
BHH Standby auxiliary section 0,38 kV from BHT62
BHK 0,38 kV section of NO reliable power supply from BHT71
BHL 0,38 kV section of NO reliable power supply from BHT72
BHT Standby auxiliary transformer 6/0,4 kV
BJ. Low-voltage subdistribution boards and transformers 6/0,4 kV, normal operation system
BJB Section 0,38 kV from BJT21 main pump station
BJC Section 0,38 kV from BJT31 main pump station
BJT Transformers 6/0,4 kV main pump station
BK. Sections 0,38 kV and transformers 6/0,4 kV of common-station
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 25
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
load
BKD 0,38 kV section of common-station load from ВКT15
BKE Section 0,38 kV from ВКT11
BKF 0,38 kV section of common-station load from ВКT11
BKG Section 0,38 kV from ВКT12
BKH Section 0,38 kV from ВКT22
BKJ Section 0,38 kV from ВКT13
BKK 0,38 kV section of common-station load from ВКT23
BKL 0,38 kV section of common-station load from ВКT14
BKM 0,38 kV section of common-station load from ВКT24
BKN Section 0,38 kV from ВКT15
BKQ 0,38 kV section of common-station load from ВКT11
BKS Section 0,38 kV from BKT17
BKT Transformer 6/0,4 kV of common-station load
BKU Section 0,38 kV from BKT27
BL. Low voltage subdistribution boards and transformers
BLT 0,38/0,415 kV matching transformer for electric lighting supply
BM. Low-voltage switchgears 0,38 kV and transformers 6/0,4 kV. Emergency power supply system
BMA Section 0,38 kV from BMT11
BMB Section 0,38 kV from BMT21
BMC Section 0,38 kV from BMT31
BMD Section 0,38 kV from BMT41
BME Section 0,38 kV from BMT12
BMF Section 0,38 kV from BMT22
BMG Section 0,38 kV from BMT32
BMH Section 0,38 kV from BMT42
BMJ Section 0,415 kV from BMT13 (6/0,433 kV)
BMK Section 0,415 kV from BMT23 (6/0,433 kV)
BML Section 0,415 kV from BMT33 (6/0,433 kV)
BMM Section 0,415 kV from BMT43 (6/0,433 kV)
BMT Auxiliary transformer 6/0,4 kV for power supply to sections
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 26
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
0,38 kV
BR. Auxiliary low-voltage switchgears, uninterrupted (inverter-type) power supply to both EPSS and NOS
BRA Power supply cabinets for MCR/SCR Channel 1 safety panel instrumentation
BRB Power supply cabinets for MCR/SCR Channel 2 safety panel instrumentation
BRC Power supply cabinets for MCR/SCR Channel 3 safety panel instrumentation
BRD Power supply cabinets for MCR/SCR Channel 4 safety panel instrumentation
BRG Power supply cabinets for MCR components (NO) and service devices
BRH TPTS power supply cabinets
BRT Inverter of emergency power supply system, normal operation system
BRU Inverter of emergency power supply system
BT. Storage battery installations
BTA Storage batteries 220 V, normal operation network
BTB Storage batteries 110 V, reactor control and protection system
BTD EPSS storage batteries 220 V
BTL Charging rectifier 220 V for normal operation system
BTM Charging-recharging rectifier 110 V, reactor control and protection system
BTP EPSS boost charging & battery charging rectifier
BU. DC boards, normal operation system
BUA DC board 220 V from BTA10
BUB DC board 220 V from BTA20
BUC DC board 220 V from BTA30
BUD DC board 220 V from BTA40
BUE DC board for chlorination plant
BUF DC board for chlorination plant
BUL Control and protection system DC board 110 V
BUM Control and protection system DC board 110 V
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 27
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
BUS Portable system for cable fault detection
BV. DC boards, emergency power supply system
BVA DC boards 220 V from BTD11
BVB DC boards 220 V from BTD21
BVC DC boards 220 V from BTD31
BVD DC boards 220 V from BTD41
BVE DC boards 220 V from BTD13
BVF DC boards 220 V from BTD23
BVG DC boards 220 V from BTD33
BVH DC boards 220 V from BTD43
BVJ DC boards 220 V from BTD12
BVK DC boards 220 V from BTD22
BVL DC boards 220 V from BTD32
BVM DC boards 220 V from BTD42
BVS Portable system for cable fault detection
C.. I&C equipment
CD. Drives control (control circuits decoupling cabinets)
CDA Alarm and control circuits decoupling cabinets of safety systems (channel 1)
CDB Alarm and control circuits decoupling cabinets of safety systems (channel 2)
CDC Alarm and control circuits decoupling cabinets of safety systems (channel 3)
CDD Alarm and control circuits decoupling cabinets of safety systems (channel 4)
CE. Alarm system
CEJ Operation important parameters registration system
CER IAEA Surveillance system
CF. Measurement, recording
CFL Radiation monitoring cabinets (for gateway)
CFM Radiation monitoring cabinets (for data storage and processing device)
CFN Radiation monitoring cabinets (for switching device)
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 28
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
CFP Radiation monitoring cabinets (for alarm device)
CFQ Archiver with time server
CH. Protection (excl. reactor protection)
CHC Main protections of the power unit (electric equipment)
CHE Main protections of the power unit (generator excitation system)
CK. Process computer system
CKA MCR working stations of Reactor Building
CKB MCR working stations of Turbine Building
CKC Common-unit working stations
CKD MCR (rear control panels) working stations
CKE Electrical shop workstations
CKF Even documenting devices (printers)
CKG Workstations
CKH Workstations
CKK Upper unit level devices (commutators)
CKL Computers for electrical part
CKM Upper unit level devices (servers)
CKN Computer aids interfacing device (safety system)
CKP Computer aids interfacing device (normal operation)
CKQ ECR working stations
CKY Cabinets of special hardware for fire alarm devices
CL. Reactor protection
CLA Reactor protection
CLA01-02 Emergency command cabinet
CLA03-04 Power supply cabinet with AC interrupting contactors
CLA05-06 Power supply cabinet with DC interrupting contactors
CLA11-13 Software and hardware system for protection
CLA14-16 Terminal cabinet
CLA21-22 Fiber-optic cross-terminal cabinet
CLA31-33 Data accumulation and processing unit
CLA41-43 Data accumulation and processing unit
CLA51-65 Characteristic conversion unit
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 29
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
CLB Reactor Protection-Actuating Part
CLB01-02 Power supply and control cabinet
CLB03-04 Power supply cabinet with AC interrupting contactors
CLB05-06 Power supply cabinet with DC interrupting contactors
CLB07 Set disabling cabinet
CLN Reactor protection
CLN11-14 Data accumulation and processing unit
CLN15-16 Interfacing and data exchange unit
CLN17 Reactor internals monitoring equipment
CLN18 Data output device
CLN21-23 Data accumulation and processing unit
CLP Reactor protection
CLP01-43 Converter transformer
CLR Group and Individual Control System
CLR01-21 Control and monitoring cabinet
CLR22-62 Power control cabinet
CLR64-65 Cabinet for multiplying the PP signals
CLR66 Signals logical processing cabinet
CLR67-78 Power supply cabinet
CLR79 Console
CLR80 Individual selection cabinet
CLR81-82 Server cabinet
CLR83-88 Intermediate terminal cabinet
CLR89 Console
CLR90 Control and monitoring cabinet
CLR91 Power control cabinet
CLR92 Cabinet of the automatic power controller
CLR93 Group indication cabinet
CLR95 Switching cabinet
CLS Reactor protection, consoles and testing sets
CM. I&C equipment
CMA Cabinets for safety equipment control and monitoring systems
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 30
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
(channel 1)
CMB Cabinets for safety equipment control and monitoring systems (channel 2)
CMC Cabinets for safety equipment control and monitoring systems (channel 3)
CMD Cabinets for safety equipment control and monitoring systems (channel 4)
CME Cabinets of monitoring and control system for electric equipment
CMF Cabinets of monitoring and control system for normal operating water purification facility
CMG Gas/powder fire suppression controllers
CMH Cabinets of monitoring and control systems for instrumentation shop
CMK Cabinets of monitoring and control systems delivered in complete set with equipment (SG PSD, PRZ PSD etc.)
CMR Cabinets for control and monitoring systems of Reactor Building normal operation equipment
CMS Cabinets for control and monitoring systems of normal operation fire-fighting equipment
CMT Cabinets for control and monitoring systems of Turbine Building normal operation equipment
CMV Cabinets for control and monitoring systems of normal operation ventilation equipment
CMW Cabinets for control and monitoring systems of normal operation SVO equipment
CMX Cabinets for control and monitoring systems of normal operation turbogenerator equipment
CMY Cabinets for control and monitoring systems of normal operation turbine governing equipment
CN. Diagnostics cabinets for special systems and analogue signal monitoring cabinets for safety systems
CNA Cabinets of analogue signal control from safety systems (channel 1)
CNB Cabinets of analogue signal control from safety systems (channel 2)
CNC Cabinets of analogue signal control from safety systems (channel 3)
CND Cabinets of analogue signal control from safety systems (channel 4)
CNN Special systems diagnostics cabinets on leaks, vibration and loose
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 31
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
parts
CNP Normal operation I&C equipment
CNQ Equipment of normal operation I&C important for safety, and normal operation I&C
CNR Commissioning measurement system
CNY Automated residual life monitoring system (ARLMS)
CP. I&C equipment
CPA I&C converter cabinets for safety systems (channel 1)
CPB I&C converter cabinets for safety systems (channel 2)
CPC I&C converter cabinets for safety systems (channel 3)
CPD I&C converter cabinets for safety systems (channel 4)
CPM I&C converter cabinets for normal operation systems of turbine building
CPR I&C converter cabinets for normal operation systems of reactor compartment
CPW I&C converter cabinets for normal operation active water purification systems
CV. Racks for information receiving and transmission equipment
CVA Safety systems cross-terminal cabinets (channel 1)
CVB Safety systems cross-terminal cabinets (channel 2)
CVC Safety systems cross-terminal cabinets (channel 3)
CVD Safety systems cross-terminal cabinets (channel 4)
CVE Cross-terminal cabinets of monitoring and control system for electric equipment
CVF Distribution cabinets for fire fighting system
CVG Cabinets of signal input from common station systems
CVK Electro-optic signals receiving and transmission equipment
CVR Reactor Building normal operation cross-terminal cabinets
CVS Normal operation cross-terminal cabinets (fire-fighting)
CVT Turbine Building normal operation cross-terminal cabinets
CVT60 Cross cabinet (counter for binding of TPTS with EMT (BRU-K) of normal operation of turbine building
CVV Normal operation ventilation equipment cross-terminal cabinets
CVW Normal operation SVO cross-terminal cabinets
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 32
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
CVX Normal operation turbogenerator cross-terminal cabinets
CVY Normal operation turbine governing cross-terminal cabinets
CVZ Cross-terminal cabinets, supplied complete with the equipment
CW. Control room
CWA MCR consoles (Reactor Building)
CWB MCR consoles (Turbine building)
CWC ECR consoles
CWD Boards of unit shift supervisor
CWE01-09 Boards and panels of GCC
CWE10-49 Boards of technical maintenance center, software engineer, instrumentation shop shift supervisor
CWE51-91 Boards and panels of GCC
CWF MCR consoles (safety system)
CWG Generalized mimic diagram
CWH MCR consoles (normal operation)
CWH01-29 MCR consoles at area of rear control panels of MCR
CWH30-39 Radiation monitoring boards
CWH41-99 MCR consoles at area of rear control panels of MCR
CWK SCR boards
CWL Boards of local crisis center, NPP shift supervisor
CWM Boards of water purification facility
CWS Panels of control board for cooling water intake systems
CX. Local control boards
CXA Cabinets for emergency power supply and control safety system buildings
CXB Cabinets for radwaste collection, processing and storage systems
CXC Control cabinets of the reloading machine
CXD Gates control system
CXF Control cabinets for cooling seawater purification systems
CXF75-80 Local boards for chlorination plant
CXG Compressor control cabinets
CXH Cabinets for liquid radwaste processing systems
CXJ Cabinets for auxiliary steam production systemsCONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 33
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
CXM Cabinets for chiller monitoring and control system
CXN Control cabinets for diesel fuel supply and used oil collection plants
CXQ Cabinets for liquid waster disposal
CXR Control cabinets for demineralizing plant regeneration system
CXS Cabinets for cooling water supply system
CXT Cabinets for chemical reagent supply and dosing systems
CXU Cabinets for fire fighting water and service water supply system
CXV Ventilation system control cabinets
CXW Power supply and control cabinets for fire retarding valves and smoke removing valves
CXY Control cabinets for drains water collection and purification systems
CY. Communication equipment
CYA Common-station telephone communication
CYB Telephone operative communication
CYC Operative loud speaking duplex communication
CYD Searching command communication
CYE Fire alarm system
CYG Common time system
CYH Announcing
CYJ Operating radio telephone system
CYL Record of the operating personnel commands
CYP Industrial television system
CYP10-20 Operative personnel actions videorecording system
CYP50-90 Surveillance System of IAEA
CYR Physical protection system
CYS Stand-by internal radio communication
CZ. Technical means of security
CZD Local annunciation system
D.. I&C equipment
DR. Low level of ARSMS
DRM Data acquisition and processing unit
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 34
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
DRN Switching unit/Controller
DW. High level of ARSMS
DWD30 ARSMS central monitoring station
DWD31 Reserve monitoring station
E.. Fuel feed
EG. Diesel fuel oil supply for the auxiliary boiler house
EGB Tank facilities
EGB01-40 Diesel fuel supply system to auxiliary boiler installation House
EGT Fuel system for the auxiliary boiler house
EGY Control, regulating and protection system
ER. Boiler kindling fuel feed
ERC Gas feed system
ERY Control, regulating and protection system
F.. Handling with nuclear fuel and activated elements
FA. Storage of fuel assemblies and other radioactive parts
FAA New fuel storage system
FAB Spent fuel storage system in the Reactor Building
FAC Spent fuel storage system outside the Reactor Building
FAD Supplementary fuel assembly storage system
FAF Temporal reactor assembly storage system
FAH Radioactive part storing (reusable) devices system
FAK Fuel pond pipelines system
FAL Storage pond water supply to purification system
FAM Irradiated fuel storage cleaning devices system
FAN Fuel storage emergency cooling system
FAT Cooling and flushing media supply to fuel elements system
FAW Sealing media supply
FAX Media supply for control, regulation and protection systems
FAY Control, regulation and protection devices
FB. Fuel element and other core parts handling systems
FBA Failed fuel assembly detection system
FBA50-80 Piping system for fluid supply to the bottles of the failed fuel
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 35
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
assembly detection system
FBB Fuel assembly and other core details repair equipment
FBC Fuel assembly and other core details cleaning equipment
FBD Fuel assembly and other reactor details mincers
FBT Media supply for heating, cooling and flushing
FBW Sealing media supply
FBX Media supply for control, regulation and protection devices
FBY Control, regulation and protection devices
FC. Fuel assemblies and other core parts reloading and handling systems
FCA Loading and removal devices (loading/removal of fuel assemblies, absorbing elements and other core details into/from the core)
FCB Reloading machine
FCC Core detail moving equipment (except for FCA and FCB)
FCD Reloading devices in storage for fuel assemblies and other core elements
FCF Equipment lock
FCJ Handling devices for fuel assemblies and other core details between various storage facilities
FCL Cooling and pressurization system for fuel assemblies handling devices
FCT Supply (evacuation) of substances for cooling, heating and flushing
FCY Control, regulation and protection devices
FJ. Fuel element and core element erection and retest systems
FJA Tooling and equipment for installation and maintenance of RPV and reactor cover
FJB Tooling and equipment for installation and maintenance of reactor internals
FJC RPV and reactor cover retest equipment
FJE Equipment and tooling for maintenance of primary components
FJF Primary component retest equipment
FJM Devices for reactor containment
FK. Equipment and room decontamination systems
FKA Reactor building equipment and room decontamination system
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 36
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
FKJ Active laundry (SVO-7) system
FKJ50 The system for preparing and supplying chemical agents to the active laundry waste water purification system
FKK RCP removable parts and other machine details decontamination devices system
FKK10-19 Controlled-access area control workshops decontamination system
FKN Mobile decontamination units system
FKT Decontamination solution preparation and supply system
FKT70-99 Decontamination solution supply system in buildings 00UKS, 00UKU, 00UYB
G.. Water supply and water discharge
GA. Fresh water acquisition (water supply and water discharge)
GAC System for seawater supply (to desalination plant) to 00UGX building
GAF Pump units for seawater supply (to desalination plant) to 00UGX building
GC. Process water demineralization systems
GCB Influent water mechanical cleaning system
GCF Influent water ion-exchange cleaning system
GCF00 Influent water ion-exchange cleaning system on trestle 00USY
GCF83-84 Demineralized water supply system
GCR Water treatment plant waste water neutralization system
GCR00 Water treatment plant waste water neutralization system on trestle 00USY
GD. Sludge demineralization systems
GH. Non-potable water distribution systems
GHA Cooling water piping for servomotor
GHC Non-potable water distribution systems after demineralization
GHC10-20 Makeup water for the auxiliary boiler house
GK. Service and potable water supply systems
GKD The domestic-drinking water pipeline
GKE Source water pipeline
GKF Hot water supply
GM. Plant drainage system
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 37
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
GMA Oil-containing water sewerage system
GMC Pump set system for oil-contaminated drains evacuation
GML System for leak collecting, removal and extraction of industrial waste waters from the main pump house 30UQA (40UQA)
GML10 Waste water collection and disposal system after automatic fire fighting of cable tunnels of the main pump house 30UQA (40UQA) (gravity system)
GML20 Waste water collection and disposal system after automatic fire fighting of cable tunnels of the main pump house 30UQA (40UQA) (pressure system)
GML30 Drainage pumping out system of the main pump house 30UQA (40UQA) (pressure system)
GMM Fire fighting, tanks emptying and drainage water collection and discharge system
GMN Pipelines of exhaust system from instrumentation compartments and compartments of secondary circuit emergency cooling-down
GMP Drain system of diesel and oil storage facilities
GN. Used process water treatment systems
GNR Flushing water and residues removal system incl. Neutralization
GNR00 Waste water after chemical flushing and preservation of equipment neutralization system on trestle 00USY
GNR10-40 Waste water after chemical flushing and preservation of equipment neutralization system
GQ. Service waste water collection and discharge systems
GQA Free access area service sewerage system
GQB Pump set system for common-access area domestic drains evacuation
GQC Pump set system for controlled-access area domestic drains evacuation
GQD Controlled access area service sewerage system
GQE Domestic sewerage of control-access area for hand-wash basins
GR. Service waste purification systems
GT. Water acquisition from industrial aqueous waste systems
GU. Rain water drain systems, including waste treatment
GUD Storm water sewerage
GUF Pump set system for rainstorm water evacuationCONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 38
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
GUU NPP ground water drains system
H.. Conventional heat generation
HH. Main combustion system
HHA Main burners
HHL Secondary air supply (combustion air)
HHM Spraying medium supply (steam)
HHR Purging medium supply (steam)
HJ. System of ignited combustion
HJA Ignition device
HJQ Cooling medium supply (air)
J.. Nuclear generation of heat
JA. Reactor systems
JAA Reactor pressure vessel, including unions and welded parts
JAB Reactor pressure vessel closure head (upper unit), including flanges, seals, studs
JAC Reactor internals
JAH Reactor external insulation
JAT Leak monitoring systems
JB. Reactor vessel internals
JBA Reactor vessel surveillance specimens
JD. Reactor control and shutdown devices
JDA CPR drive system
JDJ Fast boron concentrate injection to trip reactor
JE. Reactor cooling system (primary circuit)
JEA Steam generation system
JEA01 Air removal system from SGs on secondary circuit
JEA10-40 Steam generation system
JEA50-90 Steam generator level monitoring and pipeline steam line humidity
JEB Reactor coolant pump system
JEC Reactor coolant piping system
JEF Pressurization system
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 39
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
JEF10-40 Pressurization system
JEF50-80 Pressurizer pulse safety devices system
JEG Steam receipt from pressurizer dumping devices system
JET Reactor coolant controlled leak-off system
JEV RCP motor lubrication system
JEV50 Lubricating oil supply system to the RCP set oil tanks
JEW RCP sealing water system
JK. Reactor core with appurtenances
JKA Reactor core
JKM System for retention and cooling of reactor molten core (JKM)
JKS In-core instrumentation system
JKT Ex-core instrumentation system
JKU Fuel element cladding tubes monitoring system
JM. Containment with internals
JMA Reactor building containment shells system
JME Equipment airlock
JMF Main personnel airlock
JMG Emergency personnel airlock
JMH Installation opening
JMJ Structural components inside containment (only for component coding)
JMJ10 Relief devices system
JMK Piping penetration system
JML Cable penetration system
JMN Spray system
JMP Emergency fluid dumping out of containment and purification system
JMP30-60 System of relief devices of the reactor building steam chambers
JMT Hydrogen suppression inside the containment system
JMU Hydrogen concentration measurement inside containment system
JMX Air supply system to control localizing valves
JMY Control, regulation and protection devices
JMY10 Containment monitoring system (CMS)CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 40
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
JMY20 Leak measuring system from the containment during tightness operating tests
JN. Residual heat removal systems
JNA The system for emergency and scheduled cooling down of the primary circuit and fuel storage pool cooling
JNA80 Binding chemical agents store tanks for chemical iodine system
JNB Emergency residual heat removal system
JNB10-40 SG emergency cooldown and blowdown system
JNB50-80 Passive heat removal system
JND HP emergency injection system
JND10-40 HP emergency injection system
JND50-80 Emergency boron injection system
JNG 1st and 2nd stages accumulator system
JNG10-40 1st stage accumulator system (passive part of emergency core cooling system)
JNG50-80 2nd stage accumulator system (supplementary passive core flooding system)
JNK Borated water storage system.
JY. Control and protection equipment (other than “JR”, “JS”, “JT”)
JYF Loose parts monitoring system
JYG Vibration monitoring system
K.. Reactor plant auxiliary systems
KA. Component cooling systems
KAA Component cooling system for reactor plant loads
KAA51, 61,81
Component cooling system for reactor plant loads (heat exchangers of systems KUA10-50, KUE)
KB. Reactor coolant treatment system
KBA Volume and chemical control system
KBB Operating grade coolant storage system
KBC Boric acid and demineralized water control system
KBC10-30 Distillate system
KBC40-60 Boron concentrate system
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 41
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
KBC70 System of vertical stand hydraulic testing
KBD System for addition of chemical reagents to primary coolant
KBE Coolant purification system
KBE10-40 High temperature purification system of primary coolant
KBE50-60 Low temperature purification system of primary coolant
KBF Coolant purification system
KBH Fuel pond water purification system
KBW System of sealing fluid supply to *KB.* systems
KL. Ventilation plants in controlled area
KLA Containment (reactor building) ventilation systems
KLB Annulus space ventilation systems
KLB50-80 Annulus passive filtering system
KLC Ventilation plants for safety (controlled access area) process systems
KLE Ventilation plants for normal operation process systems, active water treatment and dirty workshop building
KLF Ventilation plants for solid radwaste treatment and storage building
KLP Ventilation plants for purification works for domestic sewage from controlled access area
KLR Ventilation plants for laboratory and service building and active laundry
KLS Ventilation plants for controlled access area of sanitary and service building
KP. Radioactive waste handling
KPA Solid radwaste processing system
KPA10-40 Solid radwaste classifying system
KPA50 Solid radwaste pressing system
KPC Concentrating plant
KPE Solid radwaste storage system
KPF Liquid radwaste processing system
KPF00 Floor water treatment system (SVO-3) on trestle 00USY
KPF10-60 Floor water treatment system
KPF70-79 Floor water collecting system in building 00UKS, 00UKU
KPH Solid radwaste burning systemCONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 42
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
KPJ Reagent preparation and supply system
KPJ70 20 % NaOH supply system
KPK Temporal liquid radioactive fluid storage system
KPL Burning system for hydrogen from radioactive process blow-offs
KPM Radioactive process blow-offs purification system
KPM40 System for purifying blow-offs from the equipment pertaining to the liguid radioactive media
KPN Cementation unit
KPP Solid radwaste fragmentation system
KPW Supply system of sealing fluid to *KP.* systems
KR. Gasses supply and removal system
KRA Nitrogen supply to flow-offs from reactor equipment
KRA00 Nitrogen supply to flow-offs from reactor equipment on trestle 0 USY
KRA10-20 System of nitrogen supply to blow-off from reactor building equipment
KRP Oxygen supply system for hydrogen after-burning systems in main building
KRQ Oxygen supply system for hydrogen burning system in special building
KRQ00 Oxygen supply system for hydrogen burning system in special building on trestle 00USY
KT. Nuclear auxiliary systems
KTA Primary drains and controlled leaks system
KTB Gaseous blow-off system
KTC Collecting system for disposal from reactor systems
KTC10-20 Collecting system of boron-containing water from reactor systems
KTF Active drainage pipework system for containment
KTH Active floor drainage system from buildings 30UJA (40UJA, 50UJA, 60UJA) and 30UKC (40UKC, 50UKC, 60UKC) (pressure)
KTM Drains system for plants of radioactive waste processing building
KTN Active drainage pipework system (traps) of 30UKC (40UKC, 50UKC, 60UKC) building
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 43
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
KTP Emergency gas removal system
KTQ Fuel storage pool lining integrity monitoring system
KTR Active floor drainage system from building 00UYB
KU. Sampling systems
KUA Sampling system for primary circuit
KUA10-50 Reactor building equipment sampling system
KUA60-80 Automated chemical monitoring system for primary circuit
KUE Sampling system from purification plants
KUJ Radioactive gaseous sampling system
KUJ11-15 Gaseous radioactive media sampling system
KUJ16 Ventilation stack gaseous radioactive media sampling system
KUK Sampling system for building 00UYB
KW. Nuclear sealing and flushing fluid supply systems
KWA System of I&C transducers hydraulic testing and flushing by distillate
KWB System of I&C transducers flushing
KWB50 Secondary-side steam generators hydraulic testing system
KWB60 Secondary-side steam generator hydraulic testing pump piping system
KWC System of hydraulic testing of the primary circuit and I&C transducers flushing
KWJ10-15 Piping system of CPS actuators stand
L.. Steam, water, gas cycles
LA. Feedwater systems
LAA Feedwater collecting and deaeration system
LAB Main feedwater piping system
LAC Feedwater pump system
LAD HP regeneration system
LAH Auxiliary feedwater piping system
LAJ Auxiliary feedwater pump system
LAY Control and protection equipment
LAY10 Monitoring, control and diagnostic system for the feed water pumps turbine drive
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 44
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
LAY20 Monitoring, control and diagnostic system for the feed water pumps
LB. Steam piping system
LBA Main steam piping system
LBB System of superheat steam piping in LP cylinder (including steam reheater)
LBC Steam supply piping system from turbine to reheater (Not Used)
LBD Steam extraction to deaerator piping system, ISH, heating water converters and so on.
LBF High pressure reducing system
LBF10 BRU-SN system
LBF50-60 BRU-D system
LBG Auxiliary steam piping system
LBG00 Auxiliary steam line system on trestle 00USY
LBG10-70 Auxiliary steam line system
LBG80 Steam supply system in 00UKS, 00UKU, 00UYB
LBG90 Pre-start heat-up system for pipe interspace of high pressure preheater
LBH Start-up, using external source, and shutdown steam system
LBJ Steam moisture separation system in LP cylinder
LBK BRU-A system
LBQ HP steam extraction piping system
LBR Piping system for TDP turbine
LBS LP steam extraction piping system
LBT BRU-K system
LBU SG safety valves system, including exhaust pipelines
LBW Turbine sealing steam system
LBW10-20 Turbine sealing steam system (including valve stems)
LBW30-50 TDP sealing steam system (including valve stems)
LC. Condensate systems
LCA Main condensate piping system
LCA70 System of main condensate supply to the deaerator and of auxiliary pipelines
LCA90 System for pre-starting fishing of the condensate and feeding line
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 45
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
LCB Main condensate pump system
LCC LP heaters system
LCE Condensate injection to BRU-K system
LCF TDP turbine condensate piping system
LCG TDP turbine condensate pump system
LCH HP heater condensate system
LCJ LP heater condensate system
LCL Steam generator drains system
LCL70 Steam generator water removal pump tank piping system
LCM Turbine hall drains system
LCM00 Turbine hall drains system (condensate collecting and return for active water treatment) on trestle 00USY
LCM10-70 Turbine hall drains system (condensate collecting and return)
LCM73-79 Heating steam condensate return system in 00UKS, 00UKU, 00UYB
LCM80-90 Turbine hall drains system (condensate collecting and return for active water treatment)
LCN HP steam piping drains system
LCP Turbine hall demineralized water system
LCQ Steam generator blowdown system
LCQ10-40 Steam generator blowdown and drains system
LCQ50-80 Steam generators blowdown water purification system
LCR TDP turbine condensate system
LCS Reheater heating steam condensate system
LCT MS/SR moisture separator condensate system
LCT51-53 MS/SR moisture separator condensate pumps system
LCW Sealing and cooling steam drains system
LCX Non-return valves control system
LD. Condensate polishing systems (UDP)
LDB Autonomous dematerializing plant system
LDB00 Autonomous dematerializing plant system on trestle 00USY
LDF Turbine condensate deironing and polishing demineralization system (UDP)
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 46
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
LDN Component cooling water chemistry control system
LDP Spent resins from UDP regeneration and flushing system
LDR UDP washing and regeneration water system
LDR00 UDP washing and regeneration water system on trestle 00USY
LF. Common installations for steam, water, gas cycles
LFC Drain and vent (steam, water, gas) system
LFG Steam generators chemical flush
LFJ Steam generator layup system
LFN Secondary working fluid correction treatment system
M.. Main machine sets
MA. Steam turbine plant
MAA HP cylinder system
MAC LP cylinder system
MAD Turbine bearings system
MAG Turbine condensers system
MAJ Air removal system
MAK Rotor hydraulic hoisting gear and turbogenerator turning gear system
MAL Turbine drain system
MAM Seal leak-off steam system
MAN Turbine bypass (BRU-K)
MAQ Oil tanks ventilation system (lubrication oil tank, control oil tank, BRU-K control oil tank)
MAV Turbogenerator lubricant facility system
MAX Turbine control lubricant supply system
MK. Generator plant
MKA Generator system
MKC Generator excitation system
MKD Generator bearings system
MKF Generator stator windings water cooling system
MKF10-50 Generator stator windings water cooling system
MKG Generator hydrogen cooling system
MKW Generator shaft sealing oil system
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 47
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
MKW10-40 Generator shaft sealing oil system
MKW50 System of generator shaft sealing oil emergency discharge
MM. Compressed air compressor plant systems
MP. Common installations for main machine sets
MPA10 Foundation of turbo set
MPA20-30 Foundation of turbo pump set
MPA40-60 Foundation of electric pump set
MV. Lubricant supply system
MVA Turbine hall loads lubricant supply system
MVA10-40 Turbine hall loads lubricant supply system
MVA50 Emergency lubricant discharge system
MVA60-70 Mineral oil supply system
MVB Auxiliary lubrication oil system
MVC Auxiliary control oil system
MVD Auxiliary BRU-K control oil system
MX. Fluid supply system for control and protection equipment
MXN BRU-K control oil supply system
P.. Cooling water plants
PA. Main cooling water system
PAA System of mechanical cleaning devices
PAB Main cooling water system
PAB90 System for air inlet-outlet from turbine condensers
PAC Pump units
PAH Turbine condenser ball cleaning system
PAS Ejector lifting pumps system
PAX Air supply system for pressure drop and water levels monitoring in PAA system
PAY Measuring system of pressure difference across screens and water levels in cooling water intake and delivery structures
PB. Main cooling water treatment system
PBB Mussels cleaning system
PBF Sodium hypochlorite mixing system
PBK Sodium hypochlorite solution delivery system to consumer
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 48
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
PC. Cooling water systems of non-essential loads
PCB Cooling water system for non-essential loads
PCB51-52 Cooling water system for common-station diesel electric station
PCC Pump units
PCD Service water supply system
PCH Heat exchanger cleaning system
PD. Main cooling water treatment of non-essential loads
PDB Mussels cleaning system
PE. Cooling water system for secured area
PEA System of mechanical cleaning devices
PEB Cooling water system for essential loads
PEC Pump units
PEH Heat exchanger cleaning plant
PEX Air supply system for pressure drop and water levels monitoring in PEA system
PEY Pressure drop and water levels monitoring in PEA system
PF. Treatment of cooling water of essential loads
PFB Mussels cleaning system
PG. Closed cooling water system for conventional area
PGB Closed cooling water system for conventional area
PGB00-70 Closed cooling water system for normal operation loads
PGB71-79 Closed cooling water system for normal operation loads in buildings 00UKS, 00UKU, 00UYB
PGB80-90 Closed cooling water system for oil coolers
PGB99 Closed cooling water system for normal operation loads on trestle 00USY
PGC Сlosed cooling water pumps system
PGD Сlosed cooling water heat exchangers system
PU. Common devices for cooling water systems
PUA Dewatering system for PAC and PCC pump units water path
PUB Dewatering system for common structures of PA, PC and PE systems
PUD Dewatering system for PEC pump units water path
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 49
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
PUE Drainage water pumping out from essential loads pump houses
PUJ Washing system of secondary screens flume of PAA system
PUK Washing system of fine-mesh rotary screens of PAA system
PUL Fish diverter ejector power supply system
PUM Fish diverter air lift power supply system
PUN System for supplying sea water to chlorine dosing plant
PUP Washing system of secondary screens flume and rotary meshes of PEA system
PUQ Essential consumers tunnels drainage and drying system
PUS Ejector pumps bearings cooling system
PUT Fish barrier rooms drainage system
PUV Oil supply system of pump units of pump stations
PUX Air supply system for pressure drop and water levels monitoring in intake structure
Q.. Auxiliary systems
QC. Central chemicals supply
QCB Nitric acid preparation and receipt system
QCB00 Nitric acid preparation and receipt system on trestle 00USY
QCD Caustic soda receipt and preparation system
QCD00 Caustic soda receipt and preparation system on trestle 00USY
QCE Hydrazine receipt and preparation system
QCE00 Hydrazine receipt and preparation system on trestle 00USY
QCF Ammonia receipt and preparation system
QCF00 Ammonia receipt and preparation system on trestle 00USY
QCQ Sulfuric acid receipt and preparation system
QCQ00 Sulfuric acid receipt and preparation system on trestle 00USY
QCR Trisodium phosphate receipt and preparation system
QCR00 Trisodium phosphate receipt and preparation system on trestle 00USY
QF. Air supply for pneumatic drives
QFA Compressed air system for valve pneumatic drives
QFA00 Compressed air system for valve pneumatic drives on trestle 00USY
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 50
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
QFA20 Compressed air supply system to the secondary circuit SG for intercircuit tightness control
QG. Central gas supply for closed gas cycles
QGA Emergency Freon discharge pipelines
QH. Auxiliary steam generation
QHA Pressure system
QHA01-03 Steam boiler
QHC Equipment for cleaning the flue gas side of the heating surfaces
QHG Boiler water circulation system
QHG10-30 Boiler continuous and periodic blowdown system
QHL Combustion air system
QHN Flue gas exhaust
QHS Feedwater chemical treatment
QHY Control, regulating and protection system
QJ. Central gas supply, also inert gas
QJB Nitrogen supply and distribution in turbine hall
QJB00 System for keeping nitrogen and supplying it in the turbine hall on trestle 00USY
QJB30 System for keeping nitrogen and supplying it in the turbine hall
QJB50 System for supplying nitrogen and distribution it in the turbine hall (for generator gas station)
QJC Hydrogen supply
QJC00 System for keeping hydrogen and supplying it in the turbine hall on trestle 00USY
QJC10 System for supplying hydrogen and distribution it in the turbine hall (for generator gas station)
QJC30 System for keeping hydrogen and supplying it in the turbine hall
QK. Cold supply systems
QKA Cold supply system for ventilation systems in conventional area (chilling machine and header pipes)
QKA00 Cold supply system for ventilation systems in conventional area (chilling machine and header pipes) on trestle 00USY
QKA01-69 Cold supply system for ventilation systems in conventional area (chilling machine)
QKA70-90 Cold supply system for ventilation systems in conventional area
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 51
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
(header pipes)
QKB Cold supply system for ventilation systems in secured area (safety chilling machine and header pipes)
QKC Cold supply system for ventilation systems in building 30UBA (40UBA, 50UBA, 60UBA)
QKD Cold supply system for ventilation systems in control safety system (CSS) and safety chilling machine emergency power supply building
QKE Cold supply system for ventilation systems in transformer building
QKF Cold supply system for ventilation systems in building of auxiliary equipment for NFS fuel element warehouses
QKJ Cold supply system for ventilation systems in reactor building
QKK Cold supply system for ventilation systems in auxiliary reactor equipment building, the NO building of control system
QKM Cold supply system for ventilation system in turbogenerator and oil building
QKN Cold supply system for ventilation system in shielded control building 00UZM
QKR Cold supply system for laboratory buildings
QKS Cold supply system for ventilation systems in building of auxiliary reactor systems
QKT Cold supply system for ventilation systems in controlled-access area central workshops building
QKZ Cold supply system for ventilation systems in cable and pipe tunnels, trains and rooms
QL. Feedwater, steam and condensate circuits for the generation and distribution of the auxiliary steam
QLA Feedwater system
QLB Steam system
QLC Condensate system
QLY Control, regulating and protection system
QS. Central oil supply and disposal system
QSB Waste oil systemQSB10-46 System of OMTI, GK, T-22 waste oilQU. Secondary automated chemical monitoring system
QUA Automated chemical monitoring system for feedwater systems
QUB Automated chemical monitoring system for steam systems
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 52
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
QUC Automated chemical monitoring system for condensate systems
QUD Sampling system for the auxiliary steam generation
QUG Automated chemical monitoring system for unit demineralizing plant systems
QUH Sampling system for secondary cycle and condensate polishing plant
QUJ The system for monitoring leak tightness of SG joints in the secondary coolant circuit
QUK Automated chemical monitoring system for steam generator blowdown systems
S.. Ancillary systems
SA. Ventilation technical plants for conventional area
SAA Ventilation plants in non-contaminated areas with safety process systems, steam line areas
SAB Ventilation plants for conventional area in sanitary and service building
SAC Ventilation plants for electrical rooms of normal operation, MCR, grid control center, ancillary outdoor switchgear installation, switchgear and control gear, control safety systems
SAD Ventilation systems for emergency power supply buildings
SAF Ventilation plants for building of auxiliary equipment for NFS fuel element warehouses
SAH Ventilation system for start-up and standby boiler house
SAJ Ventilation plants in normal operation chilling machine buildings
SAK Ventilation plants in industrial and laboratory building for I&C and electronics, training center and engineering and laboratory building
SAM Ventilation plants in turbogenerator and oil building
SAP Ventilation plants for sewerage pump stations
SAQ Ventilation plants for pump stations
SAS Ventilation plants for auxiliary equipment buildings
SAV Ventilation installations for the cable channels and rooms pertaining to the SCR
SAZ Ventilation plants for cable and pipe tunnels, trains and rooms
SB. Space heating plants for ancillary system buildings
SBH NPP heating systems
SC. Stationary process air systems
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 53
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
SCA Process air generation systems
SCB Compressed air system for process services
SCB10 Compressed air supply and distribution systems in turbine hall (for generator gas station)
SCB20 Compressed air supply and distribution systems in building 00UKS
SCB25 Compressed air supply and distribution systems in building 00USV
SCB30 Compressed air supply and distribution systems in building 00UKU
SCB40 Compressed air supply and distribution systems in building 00UYB
SCC Compressed air supply system for containment testing
SCC00 Compressed air supply system for containment testing on trestle 00USY
SCD Compressed air supply system for maintenance
SCD00 Compressed air supply system for maintenance on trestle 00USY
SCR Supplementary control room
SG. Stationary fire protection systems
SGA Common-plant fire water system
SGB Fire water system for safety systems
SGC Automatic fire water plants for rooms and equipment of normal operation systems
SGD Automatic fire water plants for rooms and equipment of safety systems
SGE Fire gas plants
SGF Foam fire-fighting systems
SGH Device for self-extinguishing of poured combustible liquids (SED)
SGK Automatic finely-dispersed water fire-fighting plants
SGL Powder fire-fighting systems
SM. Cranes, stationary hoists and conveying appliances
SMA Cranes, stationary hoisting devices and transport equipment in the 00UAB, 00UAC, 00UAD buildings
SMA20 Electric traveling cranes in buildings 00UAB, 00UAC, 00UAD
SMA21 Hand-operated traveling cranes in buildings 00UAB, 00UAC, 00UAD
SMA22 Hand-movable hoists in buildings 00UAB, 00UAC, 00UAD
SMA23 Hand hoists (fixed) in buildings 00UAB, 00UAC, 00UAD
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 54
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
SMA24 Movable electric cable hoists in buildings 00UAB, 00UAC, 00UAD
SMA25 On-floor transport in buildings 00UAB, 00UAC, 00UAD
SMA26 Hoisting sling in buildings 00UAB, 00UAC, 00UAD
SMA27 Crabs in buildings 00UAB, 00UAC, 00UAD
SMA28 Winches in buildings 00UAB, 00UAC, 00UAD
SMA29 Cross-beams in buildings 00UAB, 00UAC, 00UAD
SMA30 Grips in buildings 00UAB, 00UAC, 00UAD
SMB Cranes, stationary hoisting devices and transport equipment in the 30UBA (40UBA, 50UBA, 60UBA) building
SMB20 Electric traveling cranes in building 30UBA (40UBA, 50UBA, 60UBA)
SMB21 Hand-operated traveling cranes in building 30UBA (40UBA, 50UBA, 60UBA)
SMB22 Hand-movable hoists in building 30UBA (40UBA, 50UBA, 60UBA)
SMB23 Hand hoists (fixed) in building 30UBA (40UBA, 50UBA, 60UBA)
SMB24 Movable electric cable hoists in building 30UBA (40UBA, 50UBA, 60UBA)
SMB25 On-floor transport in building 30UBA (40UBA, 50UBA, 60UBA)
SMB26 Hoisting sling in building 30UBA (40UBA, 50UBA, 60UBA)
SMB27 Crabs in building 30UBA (40UBA, 50UBA, 60UBA)
SMB28 Winches in building 30UBA (40UBA, 50UBA, 60UBA)
SMB29 Cross-beams in building 30UBA (40UBA, 50UBA, 60UBA)
SMB30 Grips in building 30UBA (40UBA, 50UBA, 60UBA)
SMС Cranes, stationary hoisting devices and transport equipment in the 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA) buildings
SMC20 Electric traveling cranes in buildings 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA)
SMC21 Hand-operated traveling cranes in buildings 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA)
SMC22 Hand-movable hoists in buildings 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA)
SMC23 Hand hoists (fixed) in buildings 30UСC (40UСC, 50UСC, 60UСC),
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 55
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
30UCA (40UCA, 50UCA, 60UCA)
SMC24 Movable electric cable hoists in buildings 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA)
SMC25 On-floor transport in buildings 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA)
SMC26 Hoisting sling in buildings 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA)
SMC27 Crabs in buildings 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA)
SMC28 Winches in buildings 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA)
SMC29 Cross-beams in buildings 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA)
SMC30 Grips in buildings 30UСC (40UСC, 50UСC, 60UСC), 30UCA (40UCA, 50UCA, 60UCA)
SMD Cranes, stationary hoisting devices and transport equipment in the 00UYB building
SMD20 Electric travelling cranes in building 00UYB
SMD21 Hand-operated traveling cranes in building 00UYB
SMD22 Hand-movable hoists in building 00UYB
SMD23 Hand hoists (fixed) in building 00UYB
SMD24 Movable electric cable hoists in building 00UYB
SMD25 On-floor transport in buildings 00UYB
SMD26 Hoisting sling in building 00UYB
SMD27 Crabs in buildings 00UYB
SMD28 Winches in building 00UYB
SMD29 Cross-beams in building 00UYB
SMD30 Grips in building 00UYB
SME Cranes, stationary hoisting devices and transport equipment in the 00UEL, 31UEJ-34UEJ (41UEJ-44UEJ, 51UEJ-54UEJ, 61UEJ-64UEJ), 05UEJ buildings
SME20 Electric travelling cranes in building 00UEL
SME21 Hand-operated traveling cranes in building 00UEL
SME22 Hand-movable hoists in building 00UEL, 31UEJ-34UEJ (41UEJ-44UEJ, 51UEJ-54UEJ, 61UEJ-64UEJ), 05UEJ
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 56
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
SME23 Hand hoists (fixed) in building 00UEL, 31UEJ-34UEJ (41UEJ-44UEJ, 51UEJ-54UEJ, 61UEJ-64UEJ), 05UEJ
SME24 Movable electric cable hoists in building 00UEL, 31UEJ-34UEJ (41UEJ-44UEJ, 51UEJ-54UEJ, 61UEJ-64UEJ), 05UEJ
SME25 On-floor transport in building 00UEL, 31UEJ-34UEJ (41UEJ-44UEJ, 51UEJ-54UEJ, 61UEJ-64UEJ), 05UEJ
SME26 Hoisting sling in building 00UEL
SME27 Crabs in buildings 00UEL
SME28 Winches in building 00UEL
SME29 Cross-beams in building 00UEL
SME30 Grips in building 00UEL
SMF Cranes, stationary hoisting devices and transport equipment in the 00UFC building
SMF20 Electric travelling cranes in building 00UFC
SMF21 Hand-operated traveling cranes in building 00UFC
SMF22 Hand-movable hoists in building 00UFC
SMF23 Hand hoists (fixed) in building 00UFC
SMF24 Movable electric cable hoists in building 00UFC
SMF25 On-floor transport in building 00UFC
SMF26 Hoisting sling in building 00UFC
SMF27 Crabs in buildings 00UFC
SMF28 Winches in building 00UFC
SMF29 Cross-beams in building 00UFC
SMF30 Grips in building 00UFC
SMG Cranes, stationary hoisting devices and transport equipment in the 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT buildings
SMG20 Electric traveling cranes in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT
SMG21 Hand-operated traveling cranes in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 57
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
SMG22 Hand-movable hoists in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT
SMG23 Hand hoists (fixed) in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT
SMG24 Movable electric cable hoists in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT
SMG25 On-floor transport in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT
SMG26 Hoisting sling in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT
SMG27 Crabs in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT
SMG28 Winches in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT
SMG29 Cross-beams in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM 00UGV, 01UGW-02UGW, 03UGT
SMG30 Grips in buildings 00UGE, 00UGD, 01UGF-03UGF, 01UGH-02UGH, 01UGM, 00UGV, 01UGW-02UGW, 03UGT
SMJ Cranes, stationary hoisting devices and transport equipment in the 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE) buildings
SMJ20 Electric traveling crans in buildings 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMJ21 Hand-operated traveling crans in buildings 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMJ22 Hand-movable hoists in buildings 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMJ23 Hand hoists (fixed) in buildings 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMJ24 Movable electric cable hoists in buildings 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMJ25 On-floor transport in buildings 30UJA (40UJA, 50UJA, 60UJA), CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 58
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMJ26 Hoisting sling in buildings 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMJ27 Crabs in buildings 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMJ28 Winches in buildings 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMJ29 Cross-beams in buildings 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMJ30 Grips in buildings 30UJA (40UJA, 50UJA, 60UJA), 30UJB (40UJB, 50UJB, 60UJB), 30UJC (40UJC, 50UJC, 60UJC), 30UJE (40UJE, 50UJE, 60UJE)
SMK Cranes, stationary hoisting devices and transport equipment in the 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU buildings
SMK20 Electric travelling cranes in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMK21 Hand-operated traveling cranes in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMK22 Hand-movable hoists in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMK23 Hand hoists (fixed) in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMK24 Movable electric cable hoists in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD,
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 59
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMK25 On-floor transport in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMK26 Hoisting sling in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMK27 Crabs in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMK28 Winches in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMK29 Cross-beams in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMK30 Grips in buildings 30UKA (40UKA, 50UKA, 60UKA), 30UKB (40UKB, 50UKB, 60UKB), 30UKC (40UKC, 50UKC, 60UKC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 05UKD, 00UKU
SMM Cranes, stationary hoisting devices and transport equipment in the 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV) buildings
SMM20 Electric travelling cranes in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM21 Hand-operated traveling cranes in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM22 Hand-movable hoists in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM23 Hand hoists (fixed) in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM24 Movable electric cable hoists in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM25 On-floor transport in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 60
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
SMM26 Hoisting sling in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM27 Crabs in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM28 Winches in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM29 Cross-beams in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM30 Grips in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM50 Assembly trolleys in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM51 Hydraulic loaders in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM52 Coupler device in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM53 A set of testing equipment in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMM54 Anchor thrust in buildings 30UMA (40UMA, 50UMA, 60UMA), 30UMV (40UMV, 50UMV, 60UMV)
SMP Cranes, stationary hoisting devices and transport equipment in the 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK buildings
SMP20 Electric travelling cranes in buildings 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMP21 Hand-operated traveling cranes in buildings 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMP22 Hand-movable hoists in buildings 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMP23 Hand hoists (fixed) in buildings 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMP24 Movable electric cable hoists in buildings 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMP25 On-floor transport in buildings 30UPC (40UPC, 50UPC, 60UPC),
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 61
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMP26 Hoisting sling in buildings 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMP27 Crabs in buildings 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMP28 Winches in buildings 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMP29 Cross-beams in buildings 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMP30 Grips in buildings 30UPC (40UPC, 50UPC, 60UPC), 30UPX (40UPX, 50UPX, 60UPX), 30UPU (40UPU, 50UPU, 60UPU), 00UPK
SMQ Cranes, stationary hoisting devices and transport equipment in the 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX) buildings
SMQ20 Electric travelling cranes in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMQ21 Hand-operated traveling cranes in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMQ22 Hand-movable hoists in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMQ23 Hand hoists (fixed) in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMQ24 Movable electric cable hoists in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 62
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMQ25 On-floor transport in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMQ26 Hoisting sling in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMQ27 Crabs in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMQ28 Winches in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMQ29 Cross-beams in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMQ30 Grips in buildings 00UQR, 30UQA (40UQA, 50UQA, 60UQA), 31UQC-32UQC (41UQC-42UQC, 51UQC-52UQC, 61UQC-62UQC), 31UQX-34UQX (41UQX-44UQX, 51UQX-54UQX, 61UQX-64UQX)
SMS Cranes, stationary hoisting devices and transport equipment in the 00USK, 00USV, 30USA (40USA, 50USA, 60USA) buildings
SMS20 Electric travelling cranes in buildings 00USK, 00USV, 30USA (40USA, 50USA, 60USA)
SMS21 Hand-operated traveling cranes in buildings 00USK, 00USV, 30USA (40USA, 50USA, 60USA)
SMS22 Hand-movable hoists in buildings 00USK, 00USV, 30USA (40USA, 50USA, 60USA)
SMS23 Hand hoists (fixed) in buildings 00USK, , 00USV, 30USA (40USA, 50USA, 60USA)
SMS24 Movable electric cable hoists in buildings 00USK, 00USV, 30USA (40USA, 50USA, 60USA)
SMS25 On-floor transport in buildings 00USK, 00USV, 30USA (40USA, 50USA, 60USA)
SMS26 Hoisting sling in buildings 00USK, 00USV, 30USA (40USA,
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 63
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
50USA, 60USA)
SMS27 Crabs in buildings 00USK, , 00USV, 30USA (40USA, 50USA, 60USA)
SMS28 Winches in buildings 00USK, 00USV, 30USA (40USA, 50USA, 60USA)
SMS29 Cross-beams in buildings 00USK, 00USV, 30USA (40USA, 50USA, 60USA)
SMS30 Grips in buildings 00USK, 00USV, 30USA (40USA, 50USA, 60USA)
SMT Cranes, stationary hoisting devices and transport equipment in the 00UTF building
SMT20 Electric travelling cranes in buildings 00UTF
SMT21 Hand-operated traveling cranes in buildings 00UTF
SMT22 Hand-movable hoists in buildings 00UTF
SMT23 Hand hoists (fixed) in buildings 00UTF
SMT24 Movable electric cable hoists in buildings 00UTF
SMT25 On-floor transport in buildings 00UTF
SMT26 Hoisting sling in buildings 00UTF
SMT27 Crabs in buildings 00UTF
SMT28 Winches in buildings 00UTF
SMT29 Cross-beams in buildings 00UTF
SMT30 Grips in buildings 00UTF
SMU Cranes, stationary hoisting devices and transport equipment in the 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA) buildings
SMU20 Electric travelling cranes in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 64
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
SMU21 Hand-operated traveling cranes in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
SMU22 Hand-movable hoists in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
SMU23 Hand hoists (fixed) in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
SMU24 Movable electric cable hoists in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
SMU25 On-floor transport in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
SMU26 Hoisting sling in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
SMU27 Crabs in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB,
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 65
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
SMU28 Winches in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
SMU29 Cross-beams in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
SMU30 Grips in buildings 00UKS, 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 01UUB-06UUB, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB), 30UUA (40UUA, 50UUA, 60UUA)
SMU50 Hydraulic loaders in buildings 00UKS
SMU51 A set of testing equipment in buildings 00UKS
SMU52 Anchor bars in buildings 00UKS
SR. Workshops, warehouses, laboratories and staff amenities inside controlled area
SRA20 Lathe equipment in the building 00UKU
SRA30 System of lacquer emergency discharge
SRG10 Chemical laboratory equipment of primary circuit water chemistry operative monitoring
SRG20 Equipment of laboratory health physics building 00UYB
SRG50 Block radiochemical laboratory equipment of controlled access area
SRP Contaminated section of active laundry
SRP00 Water clean-up system for contaminated section of active laundry on trestle 00USY
SRP01 Condensate collecting system on trestle 00USY
SRP50 Water clean-up system for contaminated section of active laundry
SRP65 Condensate collecting system
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 66
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
ST. Workshops, warehouses, laboratories and staff amenities outside controlled area
STA20 Lathe equipment in the buildings 00USK, 00UST, 00USV
STG Common-access area laboratory equipment
STG10 Chemical laboratory equipment of secondary circuit water chemistry operative monitoring
STP Clean section of active laundry
U .. Buildings, structures
UA. Structures for grid and distribution systems
00UAB*1) 400 kV GIS Building
00UAC* Switchyard Central Control Building
00UAD* 220 kV GIS Building
03UAF* Bus shunt reactors structures
04UAF* Bus shunt reactors structures
00UAG* Interconnecting autotransformers structures
00UAH* Structure for supports and equipment
01UAK* 400 kV power line carrier communications structures
02UAK* 220 kV power line carrier communications structures
00UAL* Transmission line structures
05UAZ* Power output system 220 kV busdust tunnels for connection unit autotransformer
06UAZ* Power output system 220 kV busdust tunnels for connection unit autotransformer
31UAZ Power output system 400 kV busdust tunnels
41UAZ Power output system 400 kV busdust tunnels
51UAZ Power output system 400 kV busdust tunnels
61UAZ Power output system 400 kV busdust tunnels
32UAZ Power output system 400 kV busdust tunnels (for C (B) phase of unit transformer)
42UAZ Power output system 400 kV busdust tunnels (for C (B) phase of unit transformer)
52UAZ Power output system 400 kV busdust tunnels (for C (B) phase of unit transformer)
1*?) Code designation is common-unit and the same for Units 3-4 and 5—6CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 67
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
62UAZ Power output system 400 kV busdust tunnels (for C (B) phase of unit transformer)
33UAZ Power output system 400 kV busdust tunnels (for B (Y) phase of unit transformer)
43UAZ Power output system 400 kV busdust tunnels (for B (Y) phase of unit transformer)
53UAZ Power output system 400 kV busdust tunnels (for B (Y) phase of unit transformer)
63UAZ Power output system 400 kV busdust tunnels (for B (Y) phase of unit transformer)
34UAZ Power output system 400 kV busdust tunnels (for A (R) phase of unit transformer)
44UAZ Power output system 400 kV busdust tunnels (for A (R) phase of unit transformer)
54UAZ Power output system 400 kV busdust tunnels (for A (R) phase of unit transformer)
64UAZ Power output system 400 kV busdust tunnels (for A (R) phase of unit transformer)
UB. Structures for power transmission and auxiliary power supply
30UBA Normal Operation Power Supply Building
40UBA Normal Operation Power Supply Building
50UBA Normal Operation Power Supply Building
60UBA Normal Operation Power Supply Building
30UBF Unit Auxiliary Transformers and Generator Transformers Structures
40UBF Unit Auxiliary Transformers and Generator Transformers Structures
50UBF Unit Auxiliary Transformers and Generator Transformers Structures
60UBF Unit Auxiliary Transformers and Generator Transformers Structures
01UBG* Reserve power supply building
02UBG* Reserve power supply building
03UBG* Common-unit power supply building
04UBG* Reserve and common-unit transformers structures
02UBH* Oil and water emergency discharge tanks
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 68
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
03UBH* Oil and water emergency discharge tanks
04UBH* Oil and water emergency discharge tanks
05UBH* Oil and water emergency discharge tanks
31UBH Oil and water emergency discharge tanks
41UBH Oil and water emergency discharge tanks
51UBH Oil and water emergency discharge tanks
61UBH Oil and water emergency discharge tanks
30UBJ Rolling tracks for transformers
40UBJ Rolling tracks for transformers
50UBJ Rolling tracks for transformers
60UBJ Rolling tracks for transformers
00UBS Electrical substation
31UBZ Cable channels of normal operation systems
41UBZ Cable channels of normal operation systems
51UBZ Cable channels of normal operation systems
61UBZ Cable channels of normal operation systems
32UBZ Cable channels of normal operation systems
42UBZ Cable channels of normal operation systems
52UBZ Cable channels of normal operation systems
62UBZ Cable channels of normal operation systems
33UBZ Cable channels of normal operation systems
43UBZ Cable channels of normal operation systems
53UBZ Cable channels of normal operation systems
63UBZ Cable channels of normal operation systems
34UBZ Cable channels of normal operation systems
44UBZ Cable channels of normal operation systems
54UBZ Cable channels of normal operation systems
64UBZ Cable channels of normal operation systems
35UBZ Cable channels of normal operation systems
45UBZ Cable channels of normal operation systems
55UBZ Cable channels of normal operation systems
65UBZ Cable channels of normal operation systems
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 69
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
36UBZ Cable channels of normal operation systems
46UBZ Cable channels of normal operation systems
56UBZ Cable channels of normal operation systems
66UBZ Cable channels of normal operation systems
37UBZ Cable channels of normal operation systems
47UBZ Cable channels of normal operation systems
57UBZ Cable channels of normal operation systems
67UBZ Cable channels of normal operation systems
38UBZ Cable channels of normal operation systems
48UBZ Cable channels of normal operation systems
58UBZ Cable channels of normal operation systems
68UBZ Cable channels of normal operation systems
01UBZ* Cable channels of normal operation systems
02UBZ* Cable channels of normal operation systems
03UBZ* Cable channels of normal operation systems
04UBZ* Cable channels of normal operation systems
05UBZ* Cable channels of normal operation systems
06UBZ* Cable channels of normal operation systems
07UBZ* Cable channels of normal operation systems
08UBZ* Cable channels of normal operation systems
09UBZ* Cable channels of normal operation systems
UC. Structures for instrumentation and control
30UCA The NO building of control system
40UCA The NO building of control system
50UCA The NO building of control system
60UCA The NO building of control system
30UCC RCPS rooms
40UCC RCPS rooms
50UCC RCPS rooms
60UCC RCPS rooms
00UCM* Radiation monitoring equipment structures
00UCS Common control room
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 70
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
UE. Structures for conventional fuel supply and residues disposal
31UEH Oil and diesel receiving structure
41UEH Oil and diesel receiving structure
51UEH Oil and diesel receiving structure
61UEH Oil and diesel receiving structure
32UEH Oil and diesel receiving structure
42UEH Oil and diesel receiving structure
52UEH Oil and diesel receiving structure
62UEH Oil and diesel receiving structure
03UEH* Oil and diesel receiving structure
04UEH Oil and diesel receiving structure
05UEH* Varnish emergency discharge tank
06UEH* Diesel oil emergency discharge tank
07UEH* Column for diesel oil discharge
31UEJ Intermediate Diesel storage structures
41UEJ Intermediate Diesel storage structures
51UEJ Intermediate Diesel storage structures
61UEJ Intermediate Diesel storage structures
32UEJ Intermediate Diesel storage structures
42UEJ Intermediate Diesel storage structures
52UEJ Intermediate Diesel storage structures
62UEJ Intermediate Diesel storage structures
33UEJ Intermediate Diesel storage structures
43UEJ Intermediate Diesel storage structures
53UEJ Intermediate Diesel storage structures
63UEJ Intermediate Diesel storage structures
34UEJ Intermediate Diesel storage structures
44UEJ Intermediate Diesel storage structures
54UEJ Intermediate Diesel storage structures
64UEJ Intermediate Diesel storage structures
05UEJ* Intermediate Diesel storage structures
06UEJ Central Diesel storage facilities
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 71
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
01UEK Oil storage facilities
02UEK Oil storage facilities
00UEL Diesel and oil pump station
01UEZ* Varnish pipeline duct
02UEZ* Diesel oil pipeline duct
UF. Structures for the handling of nuclear fuel and activated elements
00UFC New fuel storage building
UG. Structures for water supply and disposal
01UGA Desalinated water tank structure
02UGA Desalinated water tank structure
03UGA Desalinated water pump station
04UGA Potable water storage tank structure
05UGA Potable water storage tank structure
01UGB DM water storage tank structure
02UGB DM water storage tank structure
03UGB DM water storage tank structure
04UGB DM water storage tank structure
05UGB DM water potable water pump station
31UGB Demineralized water storage tank structures
41UGB Demineralized water storage tank structures
51UGB Demineralized water storage tank structures
61UGB Demineralized water storage tank structures
32UGB Demineralized water storage tank structures
42UGB Demineralized water storage tank structures
52UGB Demineralized water storage tank structures
62UGB Demineralized water storage tank structures
30UGC Contaminated condensate tank structures
40UGC Contaminated condensate tank structures
50UGC Contaminated condensate tank structures
60UGC Contaminated condensate tank structures
00UGD DM water plant building & post treatment plant facility
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 72
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
01UGD Chemical storage building
02UGD Chemical laboratory
01UGE Waste water neutralization building
02UGE Waste water tank structure from chemical backwashing and conservation
03UGE Waste water tank structure from chemical backwashing and conservation
04UGE Neutralizing tank structure
05UGE Neutralizing tank structure
01UGF Fire-fighting water tank
02UGF Fire-fighting water tank
03UGF Fire-fighting service water pump station
31UGH Drainage pump station
41UGH Drainage pump station
51UGH Drainage pump station
61UGH Drainage pump station
32UGH Drainage pump station
42UGH Drainage pump station
52UGH Drainage pump station
62UGH Drainage pump station
33UGH Drainage pump station
43UGH Drainage pump station
53UGH Drainage pump station
63UGH Drainage pump station
01UGH* Storm water pump house
02UGH* Storm water pump house
01UGM* Oil containing water treatment structures
02UGM* Pump station
00UGR* Sludge damp
31UGS Backwashing water collection tank structures
41UGS Backwashing water collection tank structures
51UGS Backwashing water collection tank structures
61UGS Backwashing water collection tank structuresCONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 73
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
30UGS Backwashing water collection tank structures
40UGS Backwashing water collection tank structures
50UGS Backwashing water collection tank structures
60UGS Backwashing water collection tank structures
01UGT* Silt platform
02UGT* Gas-discharge stack
03UGT* Pump station of purified waste water
01UGU* Storm water reservoir
02UGU* Storm water reservoir
00UGV* Common-access area domestic waste water purification structures
01UGW* Pump station with receiving tank
02UGW* Production and auxiliary building
03UGW* Sand trap
04UGW* Receiving reservoir
05UGW* Stabilizer
06UGW* Settler
07UGW* Reservoir for purified drains
08UGW* Chloring contact tank
09UGW* Sand area
00UGX Desalinated plant
31UGZ Process tunnel to tanks 31UGB-32UGB, 30UGC
41UGZ Process tunnel to tanks 41UGB-42UGB, 40UGC
51UGZ Process tunnel to tanks 51UGB-52UGB, 50UGC
61UGZ Process tunnel to tanks 61UGB-62UGB, 60UGC
32UGZ Process channel to tank 31UGS
42UGZ Process channel to tank 41UGS
52UGZ Process channel to tank 51UGS
62UGZ Process channel to tank 61UGS
UJ. Structures for nuclear heat generation
30UJA Reactor building/Inner containment
40UJA Reactor building/Inner containment
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 74
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
50UJA Reactor building/Inner containment
60UJA Reactor building/Inner containment
30UJB Outer containment
40UJB Outer containment
50UJB Outer containment
60UJB Outer containment
30UJC PHRS heat exchangers room
40UJC PHRS heat exchangers room
50UJC PHRS heat exchangers room
60UJC PHRS heat exchangers room
30UJE Steam cell
40UJE Steam cell
50UJE Steam cell
60UJE Steam cell
30UJG Transport Portal
40UJG Transport Portal
50UJG Transport Portal
60UJG Transport Portal
00UJY* Gallery of the controlled access area
UK. Structures for reactor auxiliary systems
30UKA Reactor safety system. Basement
40UKA Reactor safety system. Basement
50UKA Reactor safety system. Basement
60UKA Reactor safety system. Basement
30UKB Ancillary systems. Lean-to building
40UKB Ancillary systems. Lean-to building
50UKB Ancillary systems. Lean-to building
60UKB Ancillary systems. Lean-to building
30UKC Reactor Auxiliary & Main Control Room Building
40UKC Reactor Auxiliary & Main Control Room Building
50UKC Reactor Auxiliary & Main Control Room Building
60UKC Reactor Auxiliary & Main Control Room Building
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 75
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
31UKD Emergency power supply and control building
41UKD Emergency power supply and control building
51UKD Emergency power supply and control building
61UKD Emergency power supply and control building
32UKD Emergency power supply and control building
42UKD Emergency power supply and control building
52UKD Emergency power supply and control building
62UKD Emergency power supply and control building
33UKD Emergency power supply and control building
43UKD Emergency power supply and control building
53UKD Emergency power supply and control building
63UKD Emergency power supply and control building
34UKD Emergency power supply and control building
44UKD Emergency power supply and control building
54UKD Emergency power supply and control building
64UKD Emergency power supply and control building
05UKD* Common-unit diesel generator building
31UKE Distillate storage tanks structures
41UKE Distillate storage tanks structures
51UKE Distillate storage tanks structures
61UKE Distillate storage tanks structures
32UKE Distillate storage tanks structures
42UKE Distillate storage tanks structures
52UKE Distillate storage tanks structures
62UKE Distillate storage tanks structures
31UKH Ventilation Stack
41UKH Ventilation Stack
51UKH Ventilation Stack
61UKH Ventilation Stack
02UKH* Ventilation stack on 00UKS building
03UKH* Ventilation stack on 00UKU building
00UKS* Solid radioactive waste reprocessing and storage building
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 76
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
00UKU* Controlled-access area central workshops
00UKY* Gallery of the common access area
31UKZ Cable tunnel of safety systems
41UKZ Cable tunnel of safety systems
51UKZ Cable tunnel of safety systems
61UKZ Cable tunnel of safety systems
32UKZ Cable tunnel of safety systems
42UKZ Cable tunnel of safety systems
52UKZ Cable tunnel of safety systems
62UKZ Cable tunnel of safety systems
33UKZ Cable tunnel of safety systems
43UKZ Cable tunnel of safety systems
53UKZ Cable tunnel of safety systems
63UKZ Cable tunnel of safety systems
34UKZ Cable tunnel of safety systems
44UKZ Cable tunnel of safety systems
54UKZ Cable tunnel of safety systems
64UKZ Cable tunnel of safety systems
35UKZ Cable tunnel of normal operation systems
45UKZ Cable tunnel of normal operation systems
55UKZ Cable tunnel of normal operation systems
65UKZ Cable tunnel of normal operation systems
36UKZ Cable tunnel of normal operation systems
46UKZ Cable tunnel of normal operation systems
56UKZ Cable tunnel of normal operation systems
66UKZ Cable tunnel of normal operation systems
37UKZ Cable tunnel of normal operation systems
47UKZ Cable tunnel of normal operation systems
57UKZ Cable tunnel of normal operation systems
67UKZ Cable tunnel of normal operation systems
38UKZ Cable tunnel of normal operation systems
48UKZ Cable tunnel of normal operation systems
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 77
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
58UKZ Cable tunnel of normal operation systems
68UKZ Cable tunnel of normal operation systems
UL. Structures for steam, water, gas cycles
31ULD Structure for lime cleaning waters receiving tank
41ULD Structure for lime cleaning waters receiving tank
51ULD Structure for lime cleaning waters receiving tank
61ULD Structure for lime cleaning waters receiving tank
32ULD Structures for control tank
42ULD Structures for control tank
52ULD Structures for control tank
62ULD Structures for control tank
33ULD Structures for control tank
43ULD Structures for control tank
53ULD Structures for control tank
63ULD Structures for control tank
UM. Structures for main machine sets
30UMA Turbine Building
40UMA Turbine Building
50UMA Turbine Building
60UMA Turbine Building
30UMV T & G Oil Building
40UMV T & G Oil Building
50UMV T & G Oil Building
60UMV T & G Oil Building
30UMW TB emergency oil discharge tank
40UMW TB emergency oil discharge tank
50UMW TB emergency oil discharge tank
60UMW TB emergency oil discharge tank
31UMY Process trestle to 30UGS, 31UGS, 31ULD, 32ULD, 33ULD
41UMY Process trestle to 40UGS, 41UGS, 41ULD, 42ULD, 43ULD
51UMY Process trestle to 50UGS, 51UGS, 51ULD, 52ULD, 53ULD
61UMY Process trestle to 60UGS, 61UGS, 61ULD, 62ULD, 63ULD
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 78
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
32UMY Pedestrian overpass
42UMY Pedestrian overpass
52UMY Pedestrian overpass
62UMY Pedestrian overpass
UP. Cooling water intake structures
00UPA Intake pipe
30UPC Intake structure
40UPC Intake structure
50UPC Intake structure
60UPC Intake structure
00UPK* Chlorination plant
30UPN Seawater inlet pipeline
40UPN Seawater inlet pipeline
50UPN Seawater inlet pipeline
60UPN Seawater inlet pipeline
30UPU Forebay
40UPU Forebay
50UPU Forebay
60UPU Forebay
30UPX Fish Protection Facilities
40UPX Fish Protection Facilities
50UPX Fish Protection Facilities
60UPX Fish Protection Facilities
01UPY Bridge
02UPY Bridge
30UPY Bridge
40UPY Bridge
50UPY Bridge
60UPY Bridge
31UPZ Cable channel of normal operation systems
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 79
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
41UPZ Cable channel of normal operation systems
51UPZ Cable channel of normal operation systems
61UPZ Cable channel of normal operation systems
UQ. Cooling water supply structures
30UQA Main pump house
40UQA Main pump house
50UQA Main pump house
60UQA Main pump house
31UQC Pump house of essential loads
41UQC Pump house of essential loads
51UQC Pump house of essential loads
61UQC Pump house of essential loads
32UQC Pump house of essential loads
42UQC Pump house of essential loads
52UQC Pump house of essential loads
62UQC Pump house of essential loads
31UQD Pressure pipelines of main cooling water structure
41UQD Pressure pipelines of main cooling water structure
51UQD Pressure pipelines of main cooling water structure
61UQD Pressure pipelines of main cooling water structure
32UQD Pressure pipelines of main cooling water structure
42UQD Pressure pipelines of main cooling water structure
52UQD Pressure pipelines of main cooling water structure
62UQD Pressure pipelines of main cooling water structure
30UQE Discharge pipelines of main cooling water structure
40UQE Discharge pipelines of main cooling water structure
50UQE Discharge pipelines of main cooling water structure
60UQE Discharge pipelines of main cooling water structure
30UQG Outlet pipeline inlet portion
40UQG Outlet pipeline inlet portion
50UQG Outlet pipeline inlet portion
60UQG Outlet pipeline inlet portion
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 80
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
31UQN Discharge channel
41UQN Discharge channel
51UQN Discharge channel
61UQN Discharge channel
32UQN Discharge channel
42UQN Discharge channel
52UQN Discharge channel
62UQN Discharge channel
00UQR* Chiller building
30UQU Outlet pipeline
40UQU Outlet pipeline
50UQU Outlet pipeline
60UQU Outlet pipeline
30UQW Outlet pipeline outlet portion
40UQW Outlet pipeline outlet portion
50UQW Outlet pipeline outlet portion
60UQW Outlet pipeline outlet portion
31UQX Siphon well
41UQX Siphon well
51UQX Siphon well
61UQX Siphon well
32UQX Siphon well
42UQX Siphon well
52UQX Siphon well
62UQX Siphon well
33UQX Siphon well
43UQX Siphon well
53UQX Siphon well
63UQX Siphon well
34UQX Siphon well
44UQX Siphon well
54UQX Siphon well
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 81
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
64UQX Siphon well
31UQZ Essential loads pipelines tunnels
41UQZ Essential loads pipelines tunnels
51UQZ Essential loads pipelines tunnels
61UQZ Essential loads pipelines tunnels
32UQZ Essential loads pipelines tunnels
42UQZ Essential loads pipelines tunnels
52UQZ Essential loads pipelines tunnels
62UQZ Essential loads pipelines tunnels
33UQZ Process pipelines channel
43UQZ Process pipelines channel
53UQZ Process pipelines channel
63UQZ Process pipelines channel
34UQZ Process pipelines channel
44UQZ Process pipelines channel
54UQZ Process pipelines channel
64UQZ Process pipelines channel
US. Structures for ancillary systems
30USA Turbine Building ventilation center
40USA Turbine Building ventilation center
50USA Turbine Building ventilation center
60USA Turbine Building ventilation center
30USC Air receivers structures for isolation valves
40USC Air receivers structures for isolation valves
50USC Air receivers structures for isolation valves
60USC Air receivers structures for isolation valves
01USE Hydrogen receivers structure
02USE Hydrogen receivers structure
03USE Oxygen receivers structure
04USE Oxygen receivers structure
00USF Nitrogen-oxygen station (Not used)
01USF Structure for nitrogen receivers
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 82
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
31USF Nitrogen receivers structure for Reactor Building needs
41USF Nitrogen receivers structure for Reactor Building needs
51USF Nitrogen receivers structure for Reactor Building needs
61USF Nitrogen receivers structure for Reactor Building needs
32USF Nitrogen receivers structure for Turbine Building needs
42USF Nitrogen receivers structure for Turbine Building needs
52USF Nitrogen receivers structure for Turbine Building needs
62USF Nitrogen receivers structure for Turbine Building needs
01USK Gas cylinders storage building
00USV* Engineering utility and laboratory building
00USW* Electric cable tunnels
00USY* Process trestle
01USY* Process trestle between Units 2 and 3
01USZ* Cable channel of normal operation systems
02USZ* Cable channel of normal operation systems
03USZ* Cable channel of normal operation systems
04USZ* Cable channel of normal operation systems
05USZ* Cable channel of normal operation systems
06USZ* Cable channel of normal operation systems
07USZ* Cable channel of normal operation systems
08USZ* Cable channel of normal operation systems
09USZ* Cable channel of normal operation systems
31USZ Cable channel of normal operation systems
41USZ Cable channel of normal operation systems
51USZ Cable channel of normal operation systems
61USZ Cable channel of normal operation systems
32USZ Cable channel of normal operation systems
42USZ Cable channel of normal operation systems
52USZ Cable channel of normal operation systems
62USZ Cable channel of normal operation systems
33USZ Cable channel of normal operation systems
43USZ Cable channel of normal operation systems
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 83
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
53USZ Cable channel of normal operation systems
63USZ Cable channel of normal operation systems
34USZ Cable channel of normal operation systems
44USZ Cable channel of normal operation systems
54USZ Cable channel of normal operation systems
64USZ Cable channel of normal operation systems
35USZ Cable channel of normal operation systems
45USZ Cable channel of normal operation systems
55USZ Cable channel of normal operation systems
65USZ Cable channel of normal operation systems
36USZ Cable channel of normal operation systems
46USZ Cable channel of normal operation systems
56USZ Cable channel of normal operation systems
66USZ Cable channel of normal operation systems
37USZ Cable channel of normal operation systems
47USZ Cable channel of normal operation systems
57USZ Cable channel of normal operation systems
67USZ Cable channel of normal operation systems
38USZ Cable channel of normal operation systems
48USZ Cable channel of normal operation systems
58USZ Cable channel of normal operation systems
68USZ Cable channel of normal operation systems
59USZ Cable channel of normal operation systems
69USZ Cable channel of normal operation systems
UT. Structures for auxiliary systems
00UTF* Compressor building
00UTP Nitrogen plant
00UTQ Hydrogen & oxygen plant
01UTZ* Cable tunnel of normal operation
02UTZ* Cable tunnel of normal operation
UU. Shaft structures
31UUA Exhaust ventilation center of bus duct tunnels (31UAZ - 34UAZ)
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 84
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
41UUA Exhaust ventilation center of bus duct tunnels (41UAZ - 44UAZ)
51UUA Exhaust ventilation center of bus duct tunnels (51UAZ - 54UAZ)
61UUA Exhaust ventilation center of bus duct tunnels (61UAZ - 64UAZ)
32UUA Exhaust ventilation center of bus duct tunnels (31UAZ - 34UAZ)
42UUA Exhaust ventilation center of bus duct tunnels (41UAZ - 44UAZ)
52UUA Exhaust ventilation center of bus duct tunnels (51UAZ - 54UAZ)
62UUA Exhaust ventilation center of bus duct tunnels (61UAZ - 64UAZ)
33UUA Exhaust ventilation center of bus duct tunnels (31UAZ - 34UAZ)
43UUA Exhaust ventilation center of bus duct tunnels (41UAZ - 44UAZ)
53UUA Exhaust ventilation center of bus duct tunnels (51UAZ - 54UAZ)
63UUA Exhaust ventilation center of bus duct tunnels (61UAZ - 64UAZ)
34UUA Plenum ventilation center of bus duct tunnels (31UAZ - 34UAZ)
44UUA Plenum ventilation center of bus duct tunnels (41UAZ - 44UAZ)
54UUA Plenum ventilation center of bus duct tunnels (51UAZ - 54UAZ)
64UUA Plenum ventilation center of bus duct tunnels (61UAZ - 64UAZ)
35UUA Exhaust ventilation center of bus duct tunnels (31UAZ -34UAZ)
45UUA Exhaust ventilation center of bus duct tunnels (41UAZ - 44UAZ)
55UUA Exhaust ventilation center of bus duct tunnels (51UAZ - 54UAZ)
65UUA Exhaust ventilation center of bus duct tunnels (61UAZ - 64UAZ)
36UUA Plenum ventilation center of bus duct tunnels (31UAZ - 34UAZ)
46UUA Plenum ventilation center of bus duct tunnels (41UAZ - 44UAZ)
56UUA Plenum ventilation center of bus duct tunnels (51UAZ - 54UAZ)
66UUA Plenum ventilation center of bus duct tunnels (61UAZ - 64UAZ)
37UUA Exhaust ventilation center of bus duct tunnels (31UAZ - 34UAZ)
47UUA Exhaust ventilation center of bus duct tunnels (41UAZ - 44UAZ)
57UUA Exhaust ventilation center of bus duct tunnels (51UAZ - 54UAZ)
67UUA Exhaust ventilation center of bus duct tunnels (61UAZ - 64UAZ)
01UUA* Plenum ventilation center of bus duct tunnels (05UAZ, 06UAZ)
02UUA* Exhaust ventilation center of bus duct tunnels (06UAZ)
03UUA* Exhaust ventilation center of bus duct tunnels (05UAZ)
31UUB Plenum vent center of NO cable tunnels (31UBZ - 32UBZ)
41UUB Plenum vent center of NO cable tunnels (41UBZ - 42UBZ)
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 85
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
51UUB Plenum vent center of NO cable tunnels (51UBZ - 52UBZ)
61UUB Plenum vent center of NO cable tunnels (61UBZ - 62UBZ)
32UUB Exhaust vent center of NO cable tunnels (31UBZ - 32UBZ)
42UUB Exhaust vent center of NO cable tunnels (41UBZ - 42UBZ)
52UUB Exhaust vent center of NO cable tunnels (51UBZ - 52UBZ)
62UUB Exhaust vent center of NO cable tunnels (61UBZ - 62UBZ)
33UUB Plenum vent center of NO cable tunnels (33UBZ - 34UBZ)
43UUB Plenum vent center of NO cable tunnels (43UBZ - 44UBZ)
53UUB Plenum vent center of NO cable tunnels (53UBZ - 54UBZ)
63UUB Plenum vent center of NO cable tunnels (63UBZ - 64UBZ)
35UUB Plenum vent center of NO cable tunnels (35UBZ - 38UBZ)
45UUB Plenum vent center of NO cable tunnels (45UBZ - 48UBZ)
55UUB Plenum vent center of NO cable tunnels (55UBZ - 58UBZ)
65UUB Plenum vent center of NO cable tunnels (65UBZ - 68UBZ)
02UUB* Plenum vent center of NO cable tunnels (01UBZ, 02UBZ)
04UUB* Vent shaft of NO cable tunnels (03UBZ, 04UBZ)
05UUB* Vent shaft of NO cable tunnel (06UBZ)
06UUB * Plenum vent center of NO cable tunnel (07UBZ)
31UUP Exhaust vent center essential loads pipelines tunnels (32UQZ)
41UUP Exhaust vent center essential loads pipelines tunnels (42UQZ)
51UUP Exhaust vent center essential loads pipelines tunnels (52UQZ)
61UUP Exhaust vent center essential loads pipelines tunnels (62UQZ)
32UUP Exhaust vent center essential loads pipelines tunnels (32UQZ)
42UUP Exhaust vent center essential loads pipelines tunnels (42UQZ)
52UUP Exhaust vent center essential loads pipelines tunnels (52UQZ)
62UUP Exhaust vent center essential loads pipelines tunnels (62UQZ)
33UUP Plenum vent center essential loads pipelines tunnels (32UQZ)
43UUP Plenum vent center essential loads pipelines tunnels (42UQZ)
53UUP Plenum vent center essential loads pipelines tunnels (52UQZ)
63UUP Plenum vent center essential loads pipelines tunnels (62UQZ)
34UUP Exhaust vent center essential loads pipelines tunnels (32UQZ)
44UUP Exhaust vent center essential loads pipelines tunnels (42UQZ)
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 86
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
54UUP Exhaust vent center essential loads pipelines tunnels (52UQZ)
64UUP Exhaust vent center essential loads pipelines tunnels (62UQZ)
35UUP Exhaust vent center essential loads pipelines tunnels (32UQZ)
45UUP Exhaust vent center essential loads pipelines tunnels (42UQZ)
55UUP Exhaust vent center essential loads pipelines tunnels (52UQZ)
65UUP Exhaust vent center essential loads pipelines tunnels (62UQZ)
36UUP Exhaust vent center essential loads pipelines tunnels (32UQZ)
46UUP Exhaust vent center essential loads pipelines tunnels (42UQZ)
56UUP Exhaust vent center essential loads pipelines tunnels (52UQZ)
66UUP Exhaust vent center essential loads pipelines tunnels (62UQZ)
37UUP Exhaust vent center essential loads pipelines tunnels (32UQZ)
47UUP Exhaust vent center essential loads pipelines tunnels (42UQZ)
57UUP Exhaust vent center essential loads pipelines tunnels (52UQZ)
67UUP Exhaust vent center essential loads pipelines tunnels (62UQZ)
31UUQ Exhaust vent center essential loads pipelines tunnels (31UQZ)
41UUQ Exhaust vent center essential loads pipelines tunnels (41UQZ)
51UUQ Exhaust vent center essential loads pipelines tunnels (51UQZ)
61UUQ Exhaust vent center essential loads pipelines tunnels (61UQZ)
32UUQ Exhaust vent center essential loads pipelines tunnels (31UQZ)
42UUQ Exhaust vent center essential loads pipelines tunnels (41UQZ)
52UUQ Exhaust vent center essential loads pipelines tunnels (51UQZ)
62UUQ Exhaust vent center essential loads pipelines tunnels (61UQZ)
33UUQ Plenum vent center essential loads pipelines tunnels (31UQZ)
43UUQ Plenum vent center essential loads pipelines tunnels (41UQZ)
53UUQ Plenum vent center essential loads pipelines tunnels (51UQZ)
63UUQ Plenum vent center essential loads pipelines tunnels (61UQZ)
34UUQ Exhaust vent center essential loads pipelines tunnels (31UQZ)
44UUQ Exhaust vent center essential loads pipelines tunnels (41UQZ)
54UUQ Exhaust vent center essential loads pipelines tunnels (51UQZ)
64UUQ Exhaust vent center essential loads pipelines tunnels (61UQZ)
35UUQ Exhaust vent center essential loads pipelines tunnels (31UQZ)
45UUQ Exhaust vent center essential loads pipelines tunnels (41UQZ)
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 87
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
55UUQ Exhaust vent center essential loads pipelines tunnels (51UQZ)
65UUQ Exhaust vent center essential loads pipelines tunnels (61UQZ)
36UUQ Exhaust vent center essential loads pipelines tunnels (31UQZ)
46UUQ Exhaust vent center essential loads pipelines tunnels (41UQZ)
56UUQ Exhaust vent center essential loads pipelines tunnels (51UQZ)
66UUQ Exhaust vent center essential loads pipelines tunnels (61UQZ)
37UUQ Exhaust vent center essential loads pipelines tunnels (31UQZ)
47UUQ Exhaust vent center essential loads pipelines tunnels (41UQZ)
57UUQ Exhaust vent center essential loads pipelines tunnels (51UQZ)
67UUQ Exhaust vent center essential loads pipelines tunnels (61UQZ)
31UUZ Exhaust ventilation centre of SS cable tunnel (31UKZ)
41UUZ Exhaust ventilation centre of SS cable tunnel (41UKZ)
51UUZ Exhaust ventilation centre of SS cable tunnel (51UKZ)
61UUZ Exhaust ventilation centre of SS cable tunnel (61UKZ)
32UUZ Exhaust ventilation centre of SS cable tunnel (32UKZ)
42UUZ Exhaust ventilation centre of SS cable tunnel (42UKZ)
52UUZ Exhaust ventilation centre of SS cable tunnel (52UKZ)
62UUZ Exhaust ventilation centre of SS cable tunnel (62UKZ)
33UUZ Exhaust ventilation centre of SS cable tunnel (33UKZ)
43UUZ Exhaust ventilation centre of SS cable tunnel (43UKZ)
53UUZ Exhaust ventilation centre of SS cable tunnel (53UKZ)
63UUZ Exhaust ventilation centre of SS cable tunnel (63UKZ)
34UUZ Exhaust ventilation centre of SS cable tunnel (34UKZ)
44UUZ Exhaust ventilation centre of SS cable tunnel (44UKZ)
54UUZ Exhaust ventilation centre of SS cable tunnel (54UKZ)
64UUZ Exhaust ventilation centre of SS cable tunnel (64UKZ)
35UUZ Plenum ventilation centre of SS cable tunnel (31UKZ, 32UKZ)
45UUZ Plenum ventilation centre of SS cable tunnel (41UKZ, 42UKZ)
55UUZ Plenum ventilation centre of SS cable tunnel (51UKZ, 52UKZ)
65UUZ Plenum ventilation centre of SS cable tunnel (61UKZ, 62UKZ)
36UUZ Plenum ventilation centre of SS cable tunnel (33UKZ, 34UKZ)
46UUZ Plenum ventilation centre of SS cable tunnel (43UKZ, 44UKZ)
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 88
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
56UUZ Plenum ventilation centre of SS cable tunnel (53UKZ, 54UKZ)
66UUZ Plenum ventilation centre of SS cable tunnel (63UKZ, 64UKZ)
37UUZ Exhaust ventilation centre of SS cable tunnel (32UKZ, 33UKZ)
47UUZ Exhaust ventilation centre of SS cable tunnel (42UKZ, 43UKZ)
57UUZ Exhaust ventilation centre of SS cable tunnel (52UKZ, 53UKZ)
67UUZ Exhaust ventilation centre of SS cable tunnel (62UKZ, 63UKZ)
38UUZ Exhaust ventilation centre of SS cable tunnel (31UKZ, 34UKZ)
48UUZ Exhaust ventilation centre of SS cable tunnel (41UKZ, 44UKZ)
58UUZ Exhaust ventilation centre of SS cable tunnel (51UKZ, 54UKZ)
68UUZ Exhaust ventilation centre of SS cable tunnel (61UKZ, 64UKZ)
UY. General service structures
00UYB* Health physics building (controlled-access area)
01UYE* Nuclear Island guard house
02UYE* Nuclear Island guard house
UZ. Structures for transport, traffic, fencing, gardens and other purposes
00UZA* Motor roads (in Nuclear Island)
00UZC* Construction site area
01UZJ* Nuclear Island fencing
02UZJ Central diesel storage facilities fencing
03UZJ* Standby and common unit transformers fencing
04UZJ* Coupling autotransformers and bus reactors fencing
07UZJ* Power line carrier communication structures fencing
08UZJ* Power line carrier communication structures fencing
09UZJ* Auxiliary buildings and structures area fencing
32UZJ Outdoor unit transformers fencing
42UZJ Outdoor unit transformers fencing
52UZJ Outdoor unit transformers fencing
62UZJ Outdoor unit transformers fencing
00UZM* Shielded control building
00UZN* Storm water cutoff trench
00UZP Shore-line protection bund
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 89
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
00UZQ Breakwater dike
00UZS Training dike
01UZX Artificial reef
02UZX Artificial reef
03UZX Artificial reef
01UZZ* Cable tunnel of normal operation system
02UZZ* Cable tunnel of normal operation system
X.. Heavy machinery (not main machine sets)
XA. Steam turbine plant
XAC TDP turbine and its equipment
XАQ TDP oil fumes suction system
XAV Lubricating oil supply system
XAX Control, protection and lubrication system
XJ. Systems of emergency diesel power plant
XJA Diesel engine
XJG Inner water circuit
XJN Fuel and oil storage facilities
XJN00 Fuel and oil storage facilities on trestle 0 USY
XJQ Air intake system
XJR Exhaust gas system
XJV Lubricant supply system
XJX Start-up air system
XK. Generator plant of emergency diesel generator station
XKA Generator frame, including stator, rotor and all integral cooling equipment up to leads
XL. Electric drive equipment
XLA Assembled diesel-generator
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 90
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
5 LIST OF EQUIPMENT CODES
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 91
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
A. Mechanical equipment
AA Valves, dampers, etc., incl. actuators, also manual; rupturedisk equipment
AB Isolating elements, air locks
AC Heat exchanger without a dedicated power source1) (except with ventilation system plants and equipment)
AE Turning, driving, lifting and slewing gear (also manipulators)
AF Continuous conveyors, feeders (escalators)
AG Generator units
AH Heat exchanger with a dedicated power source and/or drive2) (except with ventilation systems plants and equipment3))
AJ Crushing units
AK Compacting and packaging equipment, only as part of process
AM Mixers, agitators
AN Compressor units, fans
AP Pump units
AS Adjusting and tensioning equipment for non-electrical variables (to be applied only, if the actuator forms itself a constructive unit with another equipment unit)
AT Cleaning, drying, filtering and separating equipment
AU Braking, gearbox, coupling equipment, non-electrical converters
AV Combustion equipment
AW Stationary tooling, treatment equipment, laboratory furniture
AX Test and monitoring equipment for plant maintenance, laboratory instruments and equipment
________________________1) A heat exchanger without a dedicated power source is understood to mean an apparatus heat
transfer in which takes place directly from a heat carrier to a coolant.2) A heat exchanger with a dedicated power source is understood to mean an apparatus heat
transfer in which takes place with conversion of the energy of admitted medium into energy transferred to the medium for which this energy is required.
3) The principles for coding ventilation system plants and equipment are given in Appendix F
B. Mechanical equipment
BB Storage equipment (tanks), chamber
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 92
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
BE Shafts (for erection and maintenance only)
BF Foundations
BN Jet pumps, ejectors, injectors, deflectors, hoods
BP Flow restrictors, limiters, orifices (not metering orifices)
BQ Supports
BR Piping, ductwork, chutes
BS Silencers
BT Flue gas catalytic converter modules
BU Insulation, sheathing
C. Direct measurement circuits
CD Density
CE Electrical variables (e.g. current, voltage, power, electr. frequency)
CF Flow, rate
CG Distance, length, position, direction of rotation
CH Manual control
CK Time
CL Level (also for dividing line)
CM Moisture, humidity
CP Pressure
CQ Quality variables (analysis, material properties), other than *CD*, *CM*, *CV*
CR Radiation variables (irradiation)
CS Velocity, speed, frequency (mechanical), acceleration
CT Temperature
CU Combined and other variables
CV Viscosity
CW Weight, mass, effort
CX Neutron flux
CY Vibration, expansion
D. Control circuits
DD Density
DE Electrical variables (e.g. current, voltage, power, elect. frequency)
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 93
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
DF Flow, rate
DG Distance, length, position, direction of rotation
DK Time
DL Level (also for dividing line)
DM Moisture, humidity
DP Pressure
DQ Quality variables (analysis, material properties), other than *DD*, *DM*, *DV*
DR Radiation variables (irradiation)
DS Velocity, speed, frequency (mechanical), acceleration
DT Velocity, speed, frequency (mechanical), acceleration
DU Combined and other variables
DV Viscosity
DW Weight, mass
DX Neutron flux
DY Vibration, expansion
E. Analog and discrete signal processing (normalizing)
EA Head protections of the power unit
EB Control, group control
EC Control, subgroup control
ED Switching of the pre-selection of control modes, switching of the pre-selection (main/standby) of control valves
EE Mode interlocks
EH Alarm algorithms
EJ Emergency and warning alarm system
EK Generalized emergency and warning alarm system (failure)
EM Process computer (control over personnel and special tasks for NPP)
EN Process computer (criterion display)
EP Process computer (control), video shots
ER Reactor protection
EU Combined analog and binary signal conditioning
EY Common part of the algorithms that do not directly affect specific
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 94
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
units
EZ Protection of equipment
F. Indirect measuring circuits
FD Density
FE Design-basis electrical variables (e.g. efficiency, power)
FF Flow, rate
FG Distance, length, position, direction of rotation
FK Time
FL Level (also for dividing line)
FM Level (also for dividing line)
FP Pressure
FQ Quality variables (analysis, material properties), other than *FD*, *FM*, *FV*
FR Radiation variables
FS Velocity, speed, frequency (mechanical), acceleration
FT Temperature
FU Combined and other variables
FV Viscosity
FW Weight, mass
FX Neutron flux (reactor power)
FY Vibration, expansion
G. Electrical equipment
GA Connection boxes / penetrations for binary transducers related to actuators
GB Connection boxes / penetrations for binary transducers not related to actuators
GC Connection boxes / penetrations for analogue transducers of control safety systems
GD Connection boxes / penetrations for power cable > 1 kV
GE Connection boxes / penetrations for power cable < 1 kV
GF Connection boxes / general purpose penetrations (<60 V)
GG Penetrations, which are mechanical protection for cable and mechanical protection of cable
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 95
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
GH Independently installed electric measuring modules and control modules, which are coded according to the process system (cabinets and boxes, for which no indication of installation place is needed)
GK Information display and operator control equipment for process computers and automation systems
GM Junction boxes for light-current systems of national telecommunication services
GP Subdistribution and junction boxes for lighting
GQ Subdistribution and junction boxes for power sockets
GR DC generating equipment, batteries
GS Switchgear equipment if not identified under process equipment
GT Transformer equipment
GU Converter equipment (dynamotors, chargers)
GV Structure-related earthing and lightning protection equipment, surge arrestors
GW Cabinet power supply equipment
GX Switching equipment (for electric variables)
GY Junction boxes for light-current systems (not of national telecommunication services)
GZ Hangers, supports and racks for electrical and instrumentation and control equipment
H. Parts of main and heavy machines (only to be used in conjunction with *M* = Main machine sets and *X* = Heavy machinery)
HA Parts of casing
HB Parts of rotor
HD Bearings
J . Nuclear equipment
JA Absorbers
JB Fuel assemblies (also includes block-type, cluster-type and spherical fuel elements)
JC Multiplication elements
JD Throttling grills (elements)
JE Burnable absorbers
JF Reflecting elements
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 96
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
JG Plenum assemblies
JM Moderator assemblies
JN Neutron sources
JS Screening devices
JZ Special elements
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 97
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
6 LIST OF CODES FOR EQUIPMENT PARTS
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 98
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
К . Mechanical parts of equipment
KA Gate valves, valves, , cocks, rupture disks, orifices
KB Gates, doors
KC Heat exchangers
KD Vessels/tanks, pools, surge tanks (fluid systems)
KE Turning, hoisting and rotary mechanisms and running gears
KF Conveyors, proportioners (escalators)
KJ Size reduction machines
KK Compacting, packaging machines
KM Mixers, agitators
KN Compressors, blowers, fans
KP Pumps
KT Cleaning machines, dryers, separators, filters
KV Burners, grate bars
KW Stationary machine tools and treatment machines for maintenance
М . Mechanical parts of equipment
MB Brakes
MF Foundations
MG Gearboxes
MK Clutches, couplings
MM Engines, not electrical
MR Piping components, ductwork components
MS Shuffling drives (non-electric)
MT Turbines
MU Transmission gear, non electrical, converters and boosters other than couplings and gearboxes
Q. Instrumentation and control components (non-electrical)
QB Transducers if not structurally integral with *QP*, metering orifices
QH Signalling devices
QN Regulators
QP Measuring instruments, testing equipment
QR Instrument piping
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 99
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
QS Condensation chambers (datum reservoir) in measuring circuits
QT Protection tubes, sleeves (only as protection of delicate components)
. Electrical parts of equipment
A Assemblies and parts of assemblies
B Transducers for non-electrical to electrical variables and vice-versa
C Capacitors
D Logic elements, delay devices, memory devices
E Special components
F Protective devices
G Generators, power supplies
H Signalling devices
K Relays, contactors
L Inductors
M Motors
N Amplifiers, controllers
P Measuring instruments, testing equipment
Q Power switchgear
R Resistors
S Switches, selectors
T Transformers
U Modulators, convertors from electrical to other electrical variables
V Tubes, semiconductors
W Transmission channels, waveguides, aerials
X Terminals, plugs, sockets
Y Electric shuffling drives, e.g. magnet, solenoid
Z End devices, extension devices, filters, limiters, cable sleeves
X . (Output) signal sources
XA From functional-group control
XB From drive control modules
XC From usual controllers
XD From reactor protections, binary processing signals
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 100
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
XE From reactor protection, signals from analogue and binary parts
XF From priority control modules
XG Discrete signals from sensors
XH Analogue signals. Threshold element actuation signal for parameter value decrease or increase against the rated value.
XJ Potential signals from special devices (e.g. black box)
XK Signals generated by reactor protection
XL Signals from control boards and control panels, but not for functioning of control system itself
XM Potential static signals from emergency alarm
XN Signals from the information computer for determination of state of facility, criterion displays
XP Signals from supervisory control computer
XQ Analogue signals
XR Signals from above-standing controllers (PLC), controllers except ХС, ХТ, УС, УТ, ZC, ZT
XS Stepwise signals from functional-group control
XT Binary signals generated by turbine control hardware
XU Potential dynamic signals from alarm system
XV Discrete signals
XW From usual signalling unit
Y. (Input) signal receivers
YA For purposes of functional-group control
YB For purposes of drive control
YC For purposes of usual regulation
YD For purposes of reactor protection, binary processing signals
YE For purposes of reactor protection, signals from analogue and binary parts
YF From priority voltage modules
YJ Potential signals from special devices (e.g. black box)
YL Signals from control boards and control panels, but not for functioning of control system itself
YN Signals from the information computer for determination of state of facility, criterion displays
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 101
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Code Name
YP Signals from supervisory control computer
YQ Analogue signals
YR Signals from above-standing controllers (PLC), controllers except ХС, ХТ, УС, УТ, ZC, ZT
YT Output binary signals generated by turbine control hardware
YW For usual signalling unit
Z. Generation of mixed signal
ZA From functional-group control
ZB From drive control modules
ZC From usual controllers
ZD From reactor protections, binary processing signals
ZE From reactor protection, signals from analogue and binary parts
ZF From priority control modules
ZJ Potential signals from special devices (e.g. black box)
ZK From equipment protection
ZL Signals from control boards and control panels, but not for functioning of control system itself
ZM Input potential static signals from emergency alarm
ZN Signals from the information computer for determination of state of facility, criterion displays
ZP Signals from supervisory control computer
ZQ Analogue signals
ZR Signals from above-standing controllers (PLC), controllers except ХС, ХТ, УС, УТ, ZC, ZT
ZT Binary signals generated by turbine control hardware
ZU Potential dynamic signals from alarm system
ZV Composite signals (process interlocks, alarms)
ZW From usual signalling unit
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 102
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
APPENDIX AStructure of functional-technological code KKS
Serial no of breakdown level
0 1 2 3
Titel of breakdown level
Total plant System code Equipment unit code Component code
Designation of data character G F0 F1F2F3 FN A1A2 AN A3
2) B1B2 BN
N N AAA NN AA NNN (A) AA NN
Prefix number for system codeNumbering of similar systems and plants in the parts of a power station identified on breakdown level 0System classificationClassification of systems and plants as per KKS KeySystem numberingNumbering subdivision of systems and plants into subsystems and sections of plantsEquipment unit classificationClassification of mechanical equipment, electrical and control and instrumentation equipment as per KKS KeyEquipment unit numberingNumbering of mechanical equipment, electrical and control and instrumentation equipmentAdditional codefor the equipment unit codeComponent classificationClassification of components, signals or signal applications as per KKS KeyComponent numberingNumbering of components, signals or signal applications
2) Please see usage of code А3 in Items 6,10, Section 3 "Agreed provisions".CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 103
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
APPENDIX BNumbering in the equipment code
АА - Valves
Numerical part of code
Equipment
001-099 Motor –operated valves
101-199 Hand-operated valves
201-299 Сontrol valves
301-399 I&C valves
401-499 Structural pipeline drains. Fire and smoke dampers for ventilation systems
501-599 Hydraulic and pneumatic valves (except isolating valve)
601-699 Check valves, pressure relief valves (PRVs), ventilation channel closing devices
701-799 Internal valves
801-899 Containment isolating valves
901-999 Safety valves
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 104
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
АВ – Isolating elements
Numerical part of code
Equipment
001-099 Wooden, metal, PVC, mesh doors
101-199 Hermetic metal doors
201-299 Protective doors
301-399 Shock wave resistant doors
401-499 Fire doors
501-599 Gates
601-699 Hatches
701-799 Windows, louver grills etc.
801-899 Reserve
901-999 Reserve
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 105
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
А E – Cranes, lifting and transportation devices
Numerical part of code
Equipment
001-099 Cranes, lifting and transportation facilities in the buildings 00UAD, 30UBA (40UBA, 50UBA, 60UBA), 30UCC (40UCC, 50UCC, 60UCC), 00UEL, 00UGE, 30UJA (40UJA, 50UJA, 60UJA), 30UKC (40UKC, 50UKC, 60UKC), 30UMA (40UMA, 50UMA, 60UMA), 00UQR, 30UPC (40UPC, 50UPC, 60UPC)
100-199 Cranes, lifting and transportation facilities in the buildings 00UAB,00UGD, 30UJC (40UJC, 50UJC, 60UJC), 31UKD-34UKD (41UKD-44UKD, 51UKD-54UKD, 61UKD-64UKD), 30UMV (40UMV, 50UMV, 60UMV), 00USK, 00UTF, 00UKS, 30UPU (40UPU, 50UPU, 60UPU), 30UQA (40UQA, 50UQA, 60UQA), 30UCA (40UCA, 50UCA, 60UCA), 30UUA (40UUA, 50UUA, 60UUA)
200-299 Cranes, lifting and transportation facilities in the buildings 00UAC,01UGH-02UGH, 30UJE (40UJE, 50UJE, 60UJE), 05UKD, 00USV, 30UPX (40UPX, 50UPX, 60UPX), 30UQC (40UQC, 50UQC, 60UQC), 31UUQ-37UUQ (41UUQ-47UUQ, 51UUQ-57UUQ, 61UUQ-67UUQ)
300-399 Cranes, lifting and transportation facilities in the buildings 01UGF -03UGF, 00UKU, 30UQX (40UQX, 50UQX, 60UQX), 30USA (40USA, 50USA, 60USA), 31UUP-37UUP (41UUP-47UUP, 51UUP-57UUP, 61UUP-67UUP), 30UJB (40UJB, 50UJB, 60UJB), 00UPK
400-449 Cranes, lifting and transportation facilities in the building 30UKA (40UKA, 50UKA, 60UKA), 31UUZ-38UUZ (41UUZ-48UUZ, 51UUZ-58UUZ, 61UUZ-68UUZ), 30UFC (40UFC, 50UFC, 60UFC)
450-499 Cranes, lifting and transportation facilities in the building 30UKB (40UKB, 50UKB, 60UKB), 01UUB -06UUB
500-539 Cranes, lifting and transportation facilities in the buildings 01UGM, 31UUB-36UUB (41UUB-46UUB, 51UUB-56UUB, 61UUB-66UUB)
540-559 Cranes, lifting and transportation facilities in the building 00UGV
560-599 Cranes, lifting and transportation facilities in the building01-04UGW
600-699 Lifts
700-799 Reserve
800-899 Reserve
900-999 Reserve
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 106
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
AW – Stationary tooling, treatment equipment, laboratory furniture
Numerical part of code
Equipment
001-199 Lathe equipment in the buildings 00UKU, 00USK, laboratory furniture in the buildings 30UKC (40UKC), 30UMA (40UMA)
200-249 Lathe equipment in the building 00USV, 00UGD
250-699 Lathe equipment in the building 00UST
700-799 Reserve
800-899 Reserve
900-999 Reserve
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 107
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
BQ – Fastening equipment units
Numerical part of code
Equipment
001-099 Supports
100-199 Pipes and air ducts embedded in concrete
200-599 Embedded parts for pipelines, air ducts, instrument pipes for measuring process parameters etc passing through walls and floors
600-699 Embedded parts for equipment and pipelines of the reactor plant
700-799 Penetrations
800-899 Non-classified fastening equipment
900-999 Reserve
Accept coding rules for embedded parts and penetrations
В.1 Embedded parts and penetrations are coded generally in sector 1 of KKS functional code depending on their belonging to the structural system.
Fasteners serving for the particular system can be classified under this system.
В.2 Additional information not stipulated by KKS code, if required, can be introduced beyond the limits of KKS code. The structure of KKS code combination and additional information is given below:
KKS code
Additional information
Sector I Sector II
1 2 3 1 2
AA(А) (А) N(NNN) АА N(N)
В.3 Rules for writing designation:
sectors are designated in position of the computer keyboard “English”;
for designating alphabetic characters symbol “А” is used in the scheme, symbol “N” used for designating digital characters;
KKS code, sectors I and II are separated from one another by symbol «/»;
should one of sectors not be used it is not available in the designation;
all symbols are written in succession without making space;
symbols indicated in brackets may not be used. In this case they are not available in the designation.
В.3.1 Structure of sectors of additional information
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 108
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Sector I *
Sector 1 consists of three groups of characters:
the first group of characters consists of two or three alphabetic symbols depending on the applied code.
Group of characters АА(А) contains the code of specialized mark and is filled for identifying belonging of a fastener to the design discipline using it for its own systems. The code is adopted according to appendix B “Classifier of specialized marks “Manual on documentation coding of NPP “Kudankulam” Project”;
the second group of characters identifies:
1) types of penetrations:
S-stem penetration;
G-sealed penetration;
2) type of embedded parts for equipment and pipelines of the reactor plant:
A- embedded parts of reactor cavity up to el. +17,000 inclusive;
B- embedded parts of reactor internals well;
C- embedded parts of the cooling pond;
D- embedded parts of the pressurizer;
F- embedded parts of steam generators;
G- embedded parts of reactor coolant pumps;
H- embedded parts for ECCS;
J- embedded parts of reactor cavity above el. +17,000;
K- embedded parts for the bubbler;
L- embedded parts for main coolant pipes;
the third group of characters – registration number of location of embedded part beginning from 1.
*In coding the embedded parts for the containment air locks (the equipment, main, and emergency ones) sector I contains only the code of the respective process system JME, JMF, JMG in accordance with section 4 of this document “List of codes for process systems, buildings and structures”.
Sector II
Sector 2 consists of two groups of characters:
the first group of characters АА contains the designation of the standard embedded part for pipeline, air duct etc. – ТD;
the second group of characters N(N) – registration number of standard embedded part, beginning from 1.
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 109
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Example 1
30UJA27BQ700/EMG24
KKS code /Primary switching of electrical devices, sealed penetration №24.
Example 2
30UKC10BQ320/WK227/TD25
KKS code /Water supply and waste water disposal systems, embedded part for pipe №227/ Typical embedded part for penetration № 25.
Example 3
30UKC10BQ750/TMS7
KKS code /Mechanical part, stem penetration №7.
Example 4
30UJA12BQ605/RPВ235
KKS code /Reactor plant design, embedded part of reactor internals well №235.
В.4 Single type embedded parts (straps, squares, angles), steel structures and articles as well are marked outside KKS with obligatory indication of explanatory data in working document sets.
Structure of embedded part designations is Table B.1.
Structure of steel structure and article designations is Table B.2.
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 110
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Table B.1
Identification of embedded part
File number of basic embedded part beginning with 1 Dash
Code of basic embedded part
length beginning with 1 (taken
arbitrarily with obligatory
representation of data on the drawing)
ТА N(NN) - N(N)
Examples - ТА12-4; ТА2-56; ТА134-1
Table B.2
Conventional alphabetical designation of structure or article (according to Table B.3)
Serial number of structure or article, starting with 1
А(ААА) N(N)
Examples - МВ12, Fr1
Table B.3
Name Conventional alphabetical designation
Beam B
Framing beam FB
Console beam CB
Console C
Monorail beam MB
Monorail M
Crane-runway beam CRB
Truss Tr
Purling P
Strut Str
Tie bar TB
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 111
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Continuation of Table B.3
Name Conventional alphabetical designation
Frame Fr
Vertical brace VB
Lateral brace LB
Column Cn
Stand St
Table T
Foundation F
Support S
Ladder L
Folding platform FP
Detachable platform DP
Partition Pr
Embedded part EP
Ladder railing LR
Guard railing of platforms GR
Sheet steel decking SS
Steel grate decking SG
Sheet Sh
Steel sheet cold-formed section SSC
Cluster of penetrations CP
Floor liner FL
Wall liner WL
Ceiling liner CL
Wall paneling WP
Conduit Con
Duct Dt
Chute Ch
Flow-water sink top FST
Conduit bottom ConB
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 112
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
BR – Pipelines
Numerical part of code
Equipment
001-199 Main pipelines
200-299 Reserved
300-399 Auxiliary , supply and I&C pipelenes connections
400-499 Discharge, drenage and air exhaust pipelines
500-599 Reserved
600-699 Sampling and chemicals measuring pipelines
700-799 Internal instrumentation pipelines
800-899 Reserved
900-999 Safety valves inlet and discharge pipelines
Note - air ducts are coded with reference to the ventilation and air conditioning systems using the range 001-999 in the *BR* code numerical part.
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 113
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
С. - Circuit of direct measuring ( except CR)
Numerical part of code
Type of unit
001-199 Analog remote measuring circuits
200-299 For tests300-399 For NFME
400-499 For ICSS
500-599 Local measuring circuits
600-699 For APC
700-799 For MCDS
800-899 For reactor protection (EP), PP
900-999 Complex measuring circuits
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 114
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
CR – Radiation variables direct measuring
FR - Radiation variables indirect measuring
Numerical part of code Measuring circuit
001-099 Absorbed dose rate of photon radiation, neutron flux
100-199 Reserve
200-299 Iodine volumetric activity in air
300-399 Reserve
400-499 Aerosol volumetric activity in air
500-599 Reserve
600-699 Inert radioactive gases volumetric activity in air
700-799 Reserve
800-899 Liquid or steam volumetric activity
900-999 Reserve
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 115
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
APPENDIX CCorrelation between the service elevations and grade levels
Сode of elevation
nt.
Grade level Сode of elevation
Grade level
01 -100,000 to -_8,010 50 +40,000 to +41,99002 - 8,000 to - 7,010 51 +42,000 to +43,99003 - 7,000 to - 6,010 52 +44,000 to +45,99004 - 6,000 to - 5,010 53 +46,000 to +47,99005 - 5,000 to - 4,010 54 +48,000 to +49,99006 - 4,000 to - 3,010 55 +50,000 to +51,99007 - 3,000 to - 2,010 56 +52,000 to +53,99008 - 2,000 to - 1,010 57 +54,000 to +55,99009 - 1,000 to - 0,010 58 +56,000 to +57,99010 + 0,000 to + 0,990 59 +58,000 to +59,99011 + 1,000 to + 1,990 60 +60,000 to +61,99012 + 2,000 to + 2,990 61 +62,000 to +63,99013 + 3,000 to + 3,990 62 +64,000 to +65,99014 + 4,000 to + 4,990 63 +66,000 to +67,99015 + 5,000 to + 5,990 64 +68,000 to +69,99016 + 6,000 to + 6,990 65 +70,000 to +71,99017 + 7,000 to + 7,990 pitch 66 +72,000 to +73,990 pitch18 + 8,000 to + 8,990 1m 67 +74,000 to +75,990 2m 19 + 9,000 to + 9,990 68 +76,000 to +77,99020 +10,000 to +10,990 69 +78,000 to +79,99021 +11,000 to +11,990 70 +80,000 to +81,99022 +12,000 to +12,990 71 +82,000 to +83,99023 +13,000 to +13,990 72 +84,000 to +85,99024 +14,000 to +14,990 73 +86,000 to +87,99025 +15,000 to +15,990 74 +88,000 to +89,99026 +16,000 to +16,990 75 +90,000 to +91,99027 +17,000 to +17,990 76 +92,000 to +93,99028 +18,000 to +18,990 77 +94,000 to +95,99029 +19,000 to +19,990 78 +96,000 to +97,99030 +20,000 to +20,990 79 +98,000 to +99,99031 +21,000 to +21,990 80 +100,000 to +101,99032 +22,000 to +22,990 81 +102,000 to +103,99033 +23,000 to +23,990 82 +104,000 to +105,99034 +24,000 to +24,990 83 +106,000 to +107,99035 +25,000 to +25,990 84 +108,000 to +109,99036 +26,000 to +26,990 85 +110,000 to +111,99037 +27,000 to +27,990 86 +112,000 to +113,99038 +28,000 to +28,990 87 +114,000 to +115,99039 +29,000 to +29,990 88 +116,000 to +117,99040 +30,000 to +30,990 89 +118,000 to +119,99041 +31,000 to +31,990 9042 +32,000 to +32,990 9143 +33,000 to +33,990 9244 +34,000 to +34,990 9345 +35,000 to +35,990 9446 +36,000 to +36,990 9547 +37,000 to +37,990 9648 +38,000 to +38,990 9749 +39,000 to +39,990 98
99
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 116
Used, if necessary, for boiler roof, vent stack, cooling tower, etc.
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 117
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
APPENDIX DPrinciples of cable coding
D.1 Cable code consists of the functional technological indication and digital part divided by dash: «-» between them.
N N A A A N N ( A A N N N ) – N N ( N N A A)Number of Unit (3-6), common-unit (0),common-plant device (0 or 9)
Notation of normal operatingsystem (0) orsafety channel (1, 2, 3, 4) 1)
Functional (+equipment) code
Digital part
The following is used as functional-technological indication:
- functional code of main technological unit, to which cable belongs. The following is subject to coding: generator, transformer, a mechanism and set of relay protection hardware (for instance protection of buses of switchgear 230 kV) or a part of automated control system for technological process. The functional code is assigned to all individual cables, which serve to some technological unit of electric equipment.
- code of installation unit (cabinet, console, panel), say, in case of coding of common jumper cables between cabinets, which serve to several technological units.
In case of coding of cable, connecting two cabinets with different functional codes, the code of that cabinet is indicated, which precedes in alphabetical order.
For cable, connecting two cabinets (which belong to a group of technological units) of the same functional code, the code of cabinet with smaller number is assigned to the cable.
Power cables, feeding group assemblies, are designated according to the code of fed assembly.
Power jumper cables, interconnecting two assemblies with different functional codes, are assigned with the code of that assembly, which precedes in alphabetical order.
Digital part of cable code consists of four digits: NNNN or three digits and one letter: NNNA. For power cables the digital part of cable code consists of two digits: NN.
Digits are used for coding of groups of cables; letters can be used, if necessary, for distinguishing parallel cables and cables, passing from penetrations to the hermetic area. Parallel cables are coded with capital Latin letters except for 'G', which serves to code cables from penetrations to the hermetic area.
For example three parallel power cables from transformer 30BFT11 to section of switchgear 0,4 kV
1) A part from codes of secondary switchgears for lighting installations
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 118
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
30BFT11-01А;
30BFT11-01В;
30BFT11-01С.
Digital part of the cable code is adopted according to Table D.1.
Table D.1
Cable groups Digital part of code N N ( N N A )
Power cables (01 is recommended for assembly cables of working power supply, 02 – for back-up power supply) 01-99
DC cables 101-999
Reserve 1001-1999
Control cables for control, indication, automation, relay protection of electrical part
2001-2999,
3001-3999
Cables of process monitoring and control systems 4001-4999
5001-5999
Control cables of ULCS and special systems 6001-6999
Communication cables 7001-7999
Fire alarm and AFPS control cables 8001-8999
Reserve 9001-9999
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 119
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Digital part of codes of control cables for control, indication and relay protection are subdivided into groups with regard to directions according to Table D.2.
Table D.2
Control cable groups Digital part of code N N ( N N A )
Cables to relay board, standing apart from switchgear apparatuses and generator outlets 2001-2139
Cables from penetration to mechanism 2001G-2139G
Cables to central control board from switchgears of all voltages, generator terminals, relay boards etc.
2141-2169
Jumper cables within stand along relay board 2171-2189
Jumper cables within switchgear 2191-2269
Jumper cables within central control board 2271-2299
Measurements, control, indication and technological protection cables from all switchgears, generator terminals, local boards and cabinets to cross terminal cabinets of MCR
2301-2399
Measurements, control and indication cables, jumper cables between local boards, cabinets 2401-2499
Reserve
2501-2599
2601-2699
2701-2799
2801-2899
2901-2999
Cables from cross cabinets to TPTS cabinets (discrete) 3001-3299
Jumper cables between TPTS cabinets 3301-3499
Cables from TPTS to MCR 3501-3599
Cables from TPTS to SCR 3601-3699
Reserve
3701-3799
3801-3899
3901-3999
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 120
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Digital part of codes of cables of process monitoring and control systems are subdivided into groups with regard to directions according to Table D.3:Table D.3
Control cable groups Digital part of code N N ( N N A )
Jumper cables between:
- TPTS and TPTS, USH and USH, USH and TPTS, TPTS and interposing relay cabinets;
- TPTS and TPTS power supply cabinets;
- TPTS and cross terminal cabinet;
- USH and RCD;
- RCE and RCD
4001-4099
Cable between:
- TPTS and MCR;
- RCD and MCR
4101-4149
Cables between:
- TPTS and SCR;
- RCD and SCR
4151-4199
Cables between cross terminal cabinets, USH cabinets and LVCD 0,4 kV 4201-4299
Cables between cross terminal cabinets, USH cabinets, interposing relay cabinets and switchgear and control gear 6 kV 4301-4399
Cables between cross terminal cabinets, USH cabinets and valves or penetrations 4401-4499
Cables from penetrations (from cross terminal cabinets) to valves inside the hermetic part 4401G-4499G
Cables between cross terminal cabinets, USH cabinets and LCB 4501-4599
Cables between LVCD 0,4 kV and valves outside hermetic part or penetrations 4601-4699
Cables from penetrations (from LVCD 0,4 kV) to valves inside hermetic part 4601G-4699G
Cables between LCB and valves or LVCD 0,4 kV 4701-4799
Reserve 4801-4849
Reserve 4851-4899
Jumper cables inside MCR 4901-4949
Jumper cables inside SCR 4951-4999
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 121
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Continued Table D.3
Control cable groups Digital part of code N N ( N N A )
I&C cables, radiation monitoring cables
Cables between sensors and TPTS, USH. Nonhermetic part
Cables between sensors and junction boxes 5001-5019Cables between sensors and TPTS, USH.Cables between junction boxes and TPTS, USH 5021-5049
Cables between sensors and TPTS, USH. Hermetic part – nonhermetic part
Cables between sensors and junction boxes in hermetic part 5001-5019Cables between junction boxes and penetrations in hermetic part 5021G-5049G
Cables between penetrations and TPTS, USH 5021-5049Cables in hermetic part between sensors and penetrations – for individual cables, which are not further included in combined cables
5021G-5049G
Cables in hermetic part between sensors and penetrations – for cables, which are further included in a combined cable 5021-5049
Reserve for 1.1 and 1.2 5051-5099Cables between sensors and MCDS. Nonhermetic part
Cables between sensors and junction boxes 5101-5119Cables between sensors and MCDS.Cables between junction boxes and MCDS 5121-5149
Cables between sensors and MCDS. Hermetic part – nonhermetic part
Cables between sensors and junction boxes in hermetic part 5101-5119
Cables between sensors and penetrations in hermetic part5121G-5149G
Cables between penetrations and MCDS 5121-5149
Cables in hermetic part between sensors and penetrations – for individual cables, which are not further included in combined cables
5121G-5149G
Cables in hermetic part between sensors and penetrations – for cables, which are further included in a combined cable 5121-5149
Reserve for 2.1 and 2.2 5151-5199
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 122
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Continued Table D.3
Control cable groups Digital part of code N N ( N N A )
Cables between sensors and CPSE-ESFIP. Nonhermetic part
Cables between sensors and junction boxes 5201-5219
Cables between sensors and CPSE-ESFIP.
Cables between junction boxes and CPSE-ESFIP5221-5249
Cables between sensors and CPSE-ESFIP. Hermetic part – nonhermetic part
Cables between sensors and junction boxes in hermetic part 5201-5219
Cables between junction boxes and penetrations in hermetic part 5221G-5249G
Cables between penetrations and CPSE-ESFIP 5221-5249
Cables in hermetic part between sensors and penetrations – for individual cables, which are not further included in combined cables
5221G-5249G
Cables in hermetic part between sensors and penetrations – for cables, which are further included in a combined cable 5221-5249
Reserve for 3.1 and 3.2 5251-5259
Cables between sensors and local board
Cables between sensors and junction boxes 5301-5319
Cables between sensors and local board.
Cables between junction boxes and local board5321-5349
Reserve 5351-5399
Radiation monitoring cables
Cables in nonhermetic part between processing and accumulation devices and penetrations 5401-5499
Cables in hermetic part between sensors and penetrations 5401G-5499G
Cables to secondary converter cabinets
Cables in hermetic part from sensors to junction boxes 5501-5599
Cables in hermetic part from sensors to penetration, from junction boxes to penetration 5521G-5599G
Cables in nonhermetic part from sensors, junction boxes, penetration to panels of secondary converters 5521-5599
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 123
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Continued Table D.3
Control cable groups Digital part of code N N ( N N A )
Analog signal cables of TPTS, USH
Cables between АКС and TPTS, USH 5601-5619
Cables between CPSE-ESFIP and USH 5621-5639
Cables between USH and RCD 5641-5659
Cables between TPTS and MCR 5661-5679
Cables between TPTS and SCR 5681-5699
Analog signal cables from RCD
Cables between RCD and MCR 5701-5719
Cables between RCD and SCR 5721-5739
Reserve5801-5899
5901-5999
Digital part of codes of control cables of ULCS and special systems are subdivided into groups with regard to directions according to Table D.4.
Table D.4
Control cable groups Digital part of code N N ( N N A )
ULCS cables 6001-6199
NFME, CPSE-ESFIP cables 6201-6499
CPS electric equipment cables 6501-6699
MCDS cables 6701-6899
Reserve 6901-6999
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 124
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
Digital part of codes of fire alarm and AFPS cables are subdivided into groups with regard to directions according to Table D.5.
Table D.5
Control cable groups Digital part of code N N ( N N A )
Fire alarm cables 8001-8099
Cables between junction boxes 8101-8199Cables from junction boxes to fire station / controller 8201-8299
Cables to fire station / controller 8301-8399Cables from fire station / controller to cross terminal cabinets of MCR 8401-8499
Cables from fire station / controller to TPTS, USH 8501-8599
Cables from fire station to LCB 8601-8699
Cables connecting several fire stations 8701-8799
Reserve8801-8899
8901-8999
D.2 Cable routes shall be coded outside the KKS system, as per the pattern given below:
N N . ( N ) A A A N N N N ( A )Number of Unit (3-6), common-unit or common-plant facility (0)
Designation ofnormal operation system (0) orsafety train (1, 2, 3, 4)
Functional code (building, structure)
Serial number of route
Direction of route:- vertical: V;- horizontal: no sign is used.
Cable routes shall be coded building level-wise, from bottom to top (within the bottom and top floors):
- building level 1 – 0001 to 1000, 0001V to 1000V;
- building level 2 – 1001 to 2000, 1001V to 2000V;
- building level 3 – 2001 to 3000, 2001V to 3000V, etc.
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 125
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
D.3 Coding of electric equipment, containing code of building, structure (e.g. lighting equipment, welding equipment) with regard to cabling is to be done outside KKS in compliance with the following way:
N N . ( N ) A A A N N A A N N N ( A ) A A N NNumber of Unit (3-6), common-unit or common-plant facility (0)
Indication ofnormal operation system (0) orsafety channel (1, 2, 3, 4)
Functional code (building, structure)
Code of elevation
Code of equipment
Code of equipment part
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 126
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
APPENDIX ECoding principle of ULCS video shots
N N A A A N N A A N N N
Symbol group, repeating the KKS designation of the first APC working station, where this video shot is located (for example, 30CWA10 for SER APC video shots)
Equipment unit code EP, which defines the relation of the coded object to the video shots
Level of the hierarchy and serial number of the video shoton the APC 101-199 – video shots of the first level of the hierarchy;
201-299 - video shots of the second level of the hierarchy;
301-699 - video shots of the third level of the hierarchy;
701-999 - video shots of the fourth level of the hierarchy
Example 1 - SER APC video shot of the third level of the hierarchy.
30CWA10EP312
Example 2 - SET APC video shot of the third level of the hierarchy.
30CWB10EP305
Example 3 - APC CTAI video shot of the second level of the hierarchy
30CWE40EP201
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 127
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
APPENDIX FPrinciples for coding ventilation system plants and equipment
The codes of heating, cooling, air conditioning plants, and ventilation system filtering plants, as well as codes of equipment items used as part of these plants are assigned to them as follows:
а) Codes of plants are written in the sector of equipment unit code using the following codes:
1) *АН* with the digital range from 100 to 199 for heating, cooling and air conditioning plants;
2) *АТ* with the digital range from 100 to 199 for filtering plants;b) Equipment items that are part of the plants, except with independent air
conditioners and split systems are also encoded in the sector of equipment unit code with the digital range from 001 to 099 with application of equipment unit codes*АС* and *АН* for heat-transfer equipment according to the following principle:
1) *АС* for cooling equipment (air coolers);2) *АН* for heating equipment (air heaters, including electric heaters).Example 1 Ventilation system plenum plant 30SAC97AH100 consisting of:
- the 30SAC97AA001 air valve;- the 30SAC97AT001 filter;- the 30SAC97AH001 electric air heater;- the 30SAC97AA201 control air valve;- the 30SAC97AH002 air heater;- the 30SAC97AC001 air cooler;- the 30SAC97AT002 separator;- the 30SAC97AH003 spray chamber;- the 30SAC97AP001 spray chamber pump;- the 30SAC97AT003 separator;- the 30SAC97AN001 fan.
Example 2 The ventilation system filtering plant 30KLA22AT100 consisting of:- the 30KLA22AH001 electric air heater;- the individual aerosol and iodine purification sections 30KLA22AT001,
30KLA22AT002, etc.;Example 3. Coding of the independent air conditioner inner and outer units
20SAC98AH110 (120, 130,…) of the ventilation system:- inner unit 20SAC98AH111 (121, 131,…);- outer unit 20SAC98AH112 (122, 132,…).
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 128
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
DOCUMENT DISTRIBUTION LISTCOPY
NUMBER ORGANIZATION DATE OF
ISSUENUMBER
OF COPIES
1 JSC OKB “GIDROPRESS” 08.2017 1
2 RNC “KURCHATOV INSTITUTE” 08.2017 1
3 JSC “ATOMSTROYEXPORT” 08.2017 1
4 JSC “INSTITUTE GIDROPROEKT” 08.2017 1
CONTRACT NUMBER PACKAGE NUMBER DATE OF ISSUE REVISION NUMBER PAGE NUMBER
77-255/1624000 T2 08.2017 0 129
JSC “Atomenergoproekt” NPP “Kudankulam” R01.КК36.0.0.OO.KKS.P002
REVISION LIST
REVISION CHANGED PAGES FULL
NAME AND
SIGNATURENUMBER DATE TOTAL
QUANTITYNUMBER OF PAGE
SUMMARY