BOSCH EP test values diesel fuel-injection equipment
Test date 4/25/2013 Time: 9:10:49 AM Job. no.: ____________________Customer ID No.
Serial no.: ____________________
PUMP AND CUSTOMER DATA
PUMP DATA Edition 29.05.02
Part no. 0 460 426 273
Pump designation VE6/12F1200R738
CUSTOMER DATA Customer MAN
Engine D 0826LF18/LFL10Power 162 kW
TEST PREREQUISITESCAT Designation Unit Set value min. max. Actual values OT Test oil ISO 4113 Calibrating oil return temp. C 45 44.0 46.0 Overflow restriction mm 0.75 Inlet press. bar 0.35 0.30 0.40 Test nozzle holder assembly 1 688 901 110
Opening pressure bar 250.00 247.00 253.00 Test pressure line 1 680 750 017 Outside diameter mm 6.00 x Inside diameter mm 2.00 x Length mm 840 Shutoff solenoid V 24 Shutoff V 0
INJECTION-PUMP TEST SPECIFICATIONSOVERFLOW
CAT Designation Unit Set value min. max. Actual values OT D Temperature stabilization speed 1/min 2000 2000 D Initial temperature C 48 48 D Measurement temperature C 46 46 D Temperature stabilization speed 1/min 100 100
D Initial temperature C 42 42 D Measurement temperature C 44 44 D Temperature stabilization speed 1/min 2000 2000 D Initial temperature C 48 48 D Measurement temperature C 46 46
SETTINGS/TEST SPECIFICATONSASSEMBLY AND ADJUSTMENT DIMENSIONS
CAT Designation Unit Set value min. max. Actual values OT Dimension K mm 3.7 3.6 3.8 Dimension KF mm KOT 3 3 MS1 dimension mm 1.5 1.4 1.6 POMPE/ENGINE ASSIGNMENT S Plunger stroke mm 1.0 0.98 1.02 S Outlet A
SETTING CONTROL LEVER POSITION Control lever spacing YA mm 38.9 36.9 40.9 Control lever spacing YB mm 47.0 44.4 49.6
CAT = Category (D = Default, S = Setting value, C = Check value)OT = Outside Tolerance (X is set)