10
METODE DE REDUCERE A COSTURILOR DE EXPLOATARE PENTRU STAȚIILE DE EPURARE RURALE Mircea Vlad MUREȘAN, Elena Maria PICĂ METHODS OF REDUCING THE OPERATING COSTS FOR WASTEWATER TREATMENT IN RURAL SETTLEMENTS This paper represents an analysis of the development of sewage treament plants, in Romania, for the next decade. It also describes the current solutions to reduce operating costs for wastewater treatment. Although current solutions are viable for large capacity wastewater treatment plants, they are not efficient for small capacity water treatment plants from rural areas. This paper identifies unconventional and extensive technologies of wastewater treatment as optimal solutions for rural settlements. One of these technologies is the constructed wetlands. Identifying and understanding that constructed wetlands are the optimal solution for rural settlements is an important milestone for the aiming to reduce the energy costs at national level and thus reduce the risks related to environmental pollution. Cuvinte cheie: așezări rurale, platouri dinamice, zone umede construite, tehnologii neconvenționale, extensive Keywords: rural settlements, plateaus, constructed wetlands, unconventional technologies, extensive 1. Introducere Obiectivul principal al epurării apelor uzate îl constituie îndepărtarea substanţelor în suspensie, coloidale şi în soluţie, a 223

31 Metode de Reducere a Costurilor de Exploatare Pentru Stațiile

Embed Size (px)

DESCRIPTION

nimic

Citation preview

  • METODE DE REDUCERE A COSTURILOR DE EXPLOATARE PENTRU STAIILE

    DE EPURARE RURALE

    Mircea Vlad MUREAN, Elena Maria PIC

    METHODS OF REDUCING THE OPERATING COSTS FOR WASTEWATER TREATMENT IN RURAL SETTLEMENTS This paper represents an analysis of the development of sewage treament

    plants, in Romania, for the next decade. It also describes the current solutions to reduce operating costs for wastewater treatment. Although current solutions are viable for large capacity wastewater treatment plants, they are not efficient for small capacity water treatment plants from rural areas. This paper identifies unconventional and extensive technologies of wastewater treatment as optimal solutions for rural settlements. One of these technologies is the constructed wetlands. Identifying and understanding that constructed wetlands are the optimal solution for rural settlements is an important milestone for the aiming to reduce the energy costs at national level and thus reduce the risks related to environmental pollution.

    Cuvinte cheie: aezri rurale, platouri dinamice, zone umede construite, tehnologii neconvenionale, extensive

    Keywords: rural settlements, plateaus, constructed wetlands, unconventional technologies, extensive

    1. Introducere

    Obiectivul principal al epurrii apelor uzate l constituie ndeprtarea substanelor n suspensie, coloidale i n soluie, a

    223

  • substanelor toxice, a microorganismelor etc. din apele uzate, n scopul proteciei mediului nconjurtor (aer, sol, emisar etc.) [1].

    Staiile de epurare reprezint ansamblul de construcii i instalaii, n care apele de canalizare sunt supuse proceselor tehnologice de epurare, care le modific n aa mod calitile, nct s ndeplineasc condiiile prescrise, de deversare n receptorii naturali i de ndeprtare a substanelor reinute din aceste ape. Staiile de epurare pot fi clasificate n dou mari categorii [1]:

    oreneti; industriale.

    Prin aderarea Romniei la Uniunea European, la 1 ianuarie 2007, s-au adoptat o serie de dispoziii speciale care au sprijinit aderarea n bune condiii a acesteia. O astfel de dispoziie special este Directiva 91/271/CEE, acest document avnd ca obiectiv protecia mediului de efectele negative ale evacurilor de ape uzate i prezint etapele pe care Romnia i le propune s le urmeze privind epurarea apelor uzate, graficul de realizare n timp i costuri.

    Conform acestora, apele uzate provenite de la aglomerri umane cu mai mult de 10.000 l.e.(locuitori echivaleni) trebuie sa fie supuse unei epurri teriare (reinerea compuilor azotului i fosforului, precum i a altor impurificatori a cror structur chimic i biologic nu permite ca acetia s fie reinui i eliminai ntr-o staie de epurare obinuit) pn la data de 31 decembrie 2015, iar apele uzate provenite de la aglomerri umane cuprinse ntre 2.000-10.000 l.e. trebuie s fie supuse unei epurri biologice pn la 31 decembrie 2018 [2].

    Din aceste obiective impuse de ctre Uniunea European, se poate identifica o nou categorie de clasificare a staiilor de epurare. Aglomerrile umane cu mai mult de 10.000 l.e. se ncadreaz n categoria staiilor de epurare oreneti, iar cele cu aglomerri umane cuprinse ntre 2.000 10.000 l.e. formeaz noua categorie a staiilor de epurare rurale.

    2. Costurile de exploatare ale staiilor de epurare

    Costurile de ntreinere i exploatare se difereniaz n urmtoarele tipuri de costuri [3]:

    a) Costuri specifice de ntreinere i exploatare raportate la procesul tehnologic, cum ar fi, pentru:

    - Energie; - ntreinerea echipamentelor; - Consumabile (substane chimice, saci deshidratare etc.).

    224

  • b) Costuri specifice de ntreinere i exploatare raportate la ansamblul staiei de epurare, cum ar fi, pentru:

    - Personal; - Evacuarea deeurilor solide; - Altele (spre exemplu administrare etc.).

    Dintre acestea, costurile cu energia reprezint ponderea cea mai mare din totalul costurilor de exploatare i ntreinere.

    Sunt luate n considerare urmtoarele consumuri specifice (pe l.e.) de energie pentru staiile de epurare, referitoare la:

    Grtare i site 0,5 kWh/l.e/an Separator grsimi i deznisipator 2,2 kWh/l.e/an Decantor primar 0,6 kWh/l.e/an Modul biologic cu nmol activ 25,8 kWh/l.e/an Decantoare secundare 2,3 kWh/l.e/an ngrotor nmol 1,1 kWh/l.e/an Bazin fermentare anaerob nmol 2,9 kWh/l.e/an Fermentare i deshidratare nmol 1,2 kWh/l.e/an Altele (eliminare fosfor, administrare) 3,0 kWh/l.e/an

    n total, consumul specific anual cu energia pentru o staie de epurare este de 39,6 kWh/l.e/an, iar consumul specific zilnic cu energia este de 0,108 kWh/l.e/zi [3].

    La 1 ianuarie 2010, populaia Romniei a fost, conform Institutului Naional de Statistic, de 21.462 mii locuitori, ponderea populaiei urbane fiind de 55,1 %, iar cea a populaiei rurale de 44,9 % din totalul populaiei [4]. Conform evidenei Administraiei Naionale Apele Romne, la finalul semestrului II al anului 2011, mediul urban avea un grad de racordare la staii de epurare de 67,17 %, iar mediul rural de 7,21 % [5].

    Pentru calculul consumului specific zilnic cu energia pentru staiile de epurare de pe teritoriul Romniei n 2012, datele anterior menionate sunt centralizate n tabelul 1.

    Tabelul 1 Total populaie: 21462 mii loc. Consum specific energie: 1 l.e = 0,108 kWh/zi

    Mediu Pondere populaie total [%]

    Mii locuitori/ mediu

    Grad racordare la staiile de epurare [%]

    Mii locuitori/ mediu

    MWh/zi

    Urban 55,1 11825,56 67,17 7943,23 857,87

    Rural 44,9 9636,44 7,21 694,79 75,04

    Total: 932,91

    225

  • Consumul mediu zilnic de energie la nivel naional este de 168.000 MWh [6], iar consumul de energie specific zilnic pentru staiile de epurare este de 932,91 MWh, acesta reprezentnd 0,56 % din consumul mediu zilnic de energie la nivel naional, cu un cost zilnic de aproximativ 110.000 euro.

    Dac se presupune c Romnia i va ndeplini ndatoririle cu privire la Directiva 91/271/CEE, n anul 2018, ntreaga populaie a Romniei ar fi racordat la sisteme de epurare a apei uzate. Rezultatele consumului specific cu energia pentru staiile de epurare de pe teritoriul Romniei, n aceast ipotez este prezentat n tabelul 2.

    Tabelul 2

    Total populaie: 21462 mii loc. Consum specific energie: 1 l.e=0,108 kWh/zi

    Mediu Pondere populaie total [%]

    Mii locuitori/ mediu

    Grad racordare la staiile de epurare [%]

    Mii locuitori/ mediu MWh/zi

    Urban 55,1 11825,56 100 11825,56 1277

    Rural 44,9 9636,44 100 9636,44 1041

    Total: 2318 Datele din tabelul 1 i respectiv din tabelul 2 sunt sintetizate n

    figura 1.

    Fig. 1 Populaia total a Romniei i procentajul de racordare a acesteia

    la staiile de epurare

    226

  • n aceast ipotez consumul de energie zilnic total pentru staiile de epurare este de 2.318 MWh, reprezentnd 1,38 % din consumul mediu zilnic de energie la nivel naional i un cost zilnic de energie de aproximativ 270.000 euro, figura 2.

    Fig. 2 Consumul i costul zilnic de energiei la nivel naional, preconizat n 2018

    Din analiza figurii 2 se observ o cretere a consumului de energie

    pentru staiile de epurare n 2018 de 248 % n comparaie cu anul 2012. Ponderea cea mai mare o reprezint mediul rural, unde creterea consumului de energie preconizat n 2018 este de 1.340 % fa de anul 2012.

    Aadar, se impune o optimizare a consumurilor de energie pentru staiile de epurare existente i gsirea unor metode tehnologice cu consum redus de energie pentru staiile de epurare care se vor construi n zona rural.

    3. Metode de reducere a consumului de energie n prezent se cerceteaz noi metode de optimizare a consumului

    de energie i implicit a costurilor de exploatare. Printre metodele cele mai vehiculate se includ [7]:

    Automatizarea complex a proceselor, prin asigurarea regimurilor optime de funcionare a acestora cu consum minim de

    227

  • energie i materiale, cu o fiabilitate deosebit. Aceast metod s-a impus n aproape toate domeniile, reprezentnd astzi nu o opiune, ci o necesitate.

    Identificarea urmtoarelor surse de energie neconvenional care ar putea conduce la optimizarea energetic a staiei de epurare:

    Energie solar - panouri solare care obin direct energie termic i panouri fotovoltaice care furnizeaz direct energie electric;

    Energie eolian - prin intermediul turbinelor eoliene care produc direct energie electric cu ajutorul curenilor de aer;

    Energie geotermic - care prin intermediul pompei de cldur genereaz energie termic, folosind cldura extras din pmnt;

    Energia co-generativ - prin utilizarea biogazului produs n staia de epurare a apelor uzate n grupuri care furnizeaz direct energie electric i termic simultan cu randamente superioare (peste 70 %) n funcie de mrimea grupului.

    Energia hidraulic - prin montarea unei centrale hidroelectrice de mic putere n punctul de deversare a apei epurate n emisar.

    ntr-adevr, automatizarea complex a proceselor prin implementarea unui sistem SCADA (Supervisory Control and Data Acquisition = control supravegheat i achiziii de date) este o metod viabil pentru staiile de epurare de capacitate mare, unde exist personal specializat, iar costurile de implementare se amortizeaz ntr-o perioad relativ redus. Totui automatizarea complex a proceselor nu reprezint o soluie pentru staiile de epurare de capacitate mic din zonele rurale, unde nu exist personal specializat cu capacitate de exploatare a acestor sisteme. De asemenea, procesele tehnologice sunt simple, nefiind justificat necesitatea alegerii unui sistem complex de automatizare.

    Prin amplasarea staiilor de epurare n zonele limitrofe ale localitilor, se creeaz condiiile optime de utilizare a surselor neconvenionale de energie. Dar analiznd randamentele de conversie a surselor regenerabile n energie electric (aproximativ 20 % [8]) se constat ineficacitatea implementrii acestora raportate la costurile de investiie.

    Epurarea apelor uzate se realizeaz convenional prin intermediul proceselor tehnologice care utilizeaz echipamente electrice (exemplu: pompe, aeratoare, suflante etc.), energia consumat pentru funcionarea continu a acestora crescnd costurile de exploatare a staiei de epurare. Folosirea surselor regenerabile de energie nu reprezint soluia fiabil de reducere a acestor costuri

    228

  • datorit randamentelor sczute de conversie n energie electric i a costurilor mari de investiie.

    Metodele optime de epurare a apelor uzate le reprezint procesele tehnologice neconvenionale, care nu utilizeaz echipamente electrice pentru tratarea biologic a apei. Exemple de tehnologii neconvenionale de epurare a apelor uzate sunt cmpurile de irigare i filtrare, filtrele de nisip, cmpurile de filtrare subterane, iazurile de stabilizare i platourile dinamice sau zonele umede construite [1].

    4. Platourile dinamice

    Cele mai bine dezvoltate tehnici la nivelul staiilor de epurare a

    apelor reziduale urbane sunt procese biologice intensive. Principiul const n exploatarea pe un spaiu mic, intensificarea degradrii naturale a materiilor organice i nlturarea nutrienilor. O astfel de tehnologie consacrat i dezvoltat este sistemul cu nmol activ cu aerare continu, care necesit o alimentare permanent cu energie electric, precum i un personal calificat pentru exploatare i ntreinere. Tehnologiile extensive au avantaje considerabile att n ceea ce privete cheltuielile de investiie ct i de exploatare. Procedeul de epurare extensiv se bazeaz pe culturi de bacterii. Epurarea se asigur datorit reteniei de lung durat care necesit un spaiu mai larg dect n cazul sistemelor intensive. Metodele de epurare n platouri dinamice au o performan ridicat, costuri sczute, consum mic de energie (uneori chiar egal cu zero) i procedeu de epurare cu necesitate redus de ntreinere, foarte potrivite zonelor rurale [9].

    Platourile dinamice sunt ecosisteme naturale unde apele reziduale sunt introduse pentru epurare biologic i fizic ntr-un filtru de nisip pe care se dezvolt vegetaie. Patul filtrant poate fi format din materiale precum nisip sau pietri de diferite granulaii i izolat etan (cu geotextil i geomembran). Tratarea apelor uzate este asigurat prin activitatea bacteriilor de pe biofilmul substratului i filtrului fizic ct i prin efectele absorbante. Pentru accelerarea procesului pe toat suprafaa filtrului de nisip se cultiv plante, de obicei trestie, din acest motiv deseori sunt denumite filtr cu pat de trestie.

    Exist diferite tipuri de sisteme, ns predomin utilizarea sistemului subsuperficial n care nivelul apelor se menine sub acela al suprafeei. n general, zonele umede construite cuprind o etap de tratare mecanic prealabil pentru sedimentarea materiilor organice solide cu scopul evitrii colmatrii.

    229

  • O tratare neeficient poate rezulta prin acumulri n punctul de descrcare a influentului, miros neplcut, colmatarea filtrului sau blocaje ale conductelor de nfiltrare. Tratarea prealabil poate fi realizat prin sedimentare primar n decantoare. Pentru instalaiile de dimensiuni mici de regul se folosesc fosele septice, figura 3. Nmolul primar trebuie evacuat frecvent (o dat pe an).

    Fig. 3 Platou dinamic cu flux vertical i pretratare mecanic [10]

    Zona umed construit, dup tratarea mecanic, poate fi un procedeu cu o singur etap. Alimentarea platourilor dinamice se realizeaz intermitent, pentru a se asigura condiiile aerobe n filtru.

    Criteriile de proiectare pentru platoul dinamic sunt suprafa de 4 m2/l.e i o ncrcare hidraulic zilnic de 80 mm. Adncimea patului filtrant este ntre 0,5 - 1,0 m. Corpul filtrant se alctuiete din umplutur de nisip i pietri. n stratul inferior de granulaie mare (filtru invers) se monteaz tuburile de drenaj, figura 4.

    Tehnologia platourilor dinamice este fundamentat pe capacitatea de epurare a trei elemente principale: comunitatea microbian dezvoltat n patul filtrant, proprietile fizice i chimice ale stratului filtrant i plantele care populeaz platoul dinamic.

    Microorganismele se ataeaz de particulele de nisip sau pietri i de rdcinile plantelor. Acestea metabolizeaz materiile poluante, le degradeaz i le mineralizeaz [12].

    Alegerea componenei stratului filtrant este foarte important i depinde de cerinele aplicaiei. Componena straturilor filtrante trebuie s permit un timpul de tranzitare a acestuia de aproximativ 60 de secunde [13].

    230

  • Fig. 4 Seciune printr-un platou filtrant [11]

    Plantele ndeplinesc trei funcii n cadrul platoului dinamic. Sistemul foarte extins de rdcini creeaz, n primul rnd, canale pentru ca influentul s treac prin patul de nisip.

    n al doilea rnd, rdcinile introduc oxigen n substraturile biofiltrului i asigur mediul unde bacteriile aerobice se pot dezvolta. Aceste organisme sunt necesare pentru a descompune multe tipuri de compui, n special oxidarea azotului n nitrai.

    n al treilea rnd, plantele asimileaz cantiti de nutrieni din apa uzat.

    n timpul sezonului cald, aproximativ 15 % din capacitatea de tratare a biofiltrului are loc pe aceast cale. Plantele sunt de asemenea capabile s acumuleze anumite metale grele, o arie de aplicare care prezint un mare interes de cercetare n prezent.

    5. Concluzii Utilizarea platourilor dinamice pentru mbuntirea calitii

    apei uzate menajere este o tehnologie n dezvoltare. Totodat, reprezint soluia ideal pentru tratarea apelor uzate menajere provenite de la aezri rurale de capacitate mic, fiind o metod care epureaz suficient apele uzate menajere.

    Aceast metod este optim din punctul de vedere al costurilor de exploatare i ntreinere i ecoresponsabil n ceea ce privete protejarea tuturor componentelor mediului nconjurtor.

    231

  • ACKNOWLEDGMENT

    Aceast lucrarea a fost realizat beneficiind de sprijinul colii Doctorale a Universitii Tehnice Cluj-Napoca.

    BIBLIOGRAFIE

    [1] Ionescu, G.C., Sisteme de epurare a apelor uzate, Editura MatixRom, Bucureti, 2010, pag. 9 i 114. [2] * * * Guvernul Romniei, Plan de implementare pentru Directiva 91/271/CEE privind epurarea apelor uzate oreneti modificat prin Directiva 98/15/CE, 2004, pag. 39. [3] * * * Primria Trgu Mure, Anexa D1.2 Costuri de exploatare i ntreinere Primrie costuri exploatare,2005, Plan Director, pag. 3 i 4 [online] Disponibil la: . [4] * * * Institutul Naional de Statistic, Populaia Romniei pe localiti la 1 ianuarie 2010, ISSN: 2066-2181, 2010, pag. 3. [5] * * * Administraia Naional Apele Romne, Stadiul realizrii lucrrilor pentru epurarea apelor uzate urbane i a capacitilor n execuie i puse n funciune pentru aglomerri umane, n semestrul II 2011, 2012, pag. 1. [6] * * * http://www.sistemulenergetic.com. [7] Gligor, E.T., Contribuii la optimizarea energetic a instalaiilor i echipamentelor din cadrul staiilor de epurare a apelor uzate, Rezumat al Tezei de doctorat, 2011, pag. 11 i 17. [8] * * * http://ro.wikipedia.org/wiki/Energie_solar%C4%83_fotovoltaic%C4%83. [9] Wendland, C., Albold, A., Sisteme de epurare durabile i eficiente a apelor reziduale din comunitile rurale i suburbane cu pn la 10000 PE, Editura WECF(Women in Europe for a Common Future), 2010, pag. 3 i 18-20. [10] * * * http://www.bodenfilter.de/engdef.htm. [11] DuPoldt, C., Edwards, R., Garber, L., Isaacs, B., A handbook of Constructed Wetlands, 1995, Vol.1, pag. 6-8. [12] * * * http://www.ciwem.org/policy-and-international/current-topics/water-management/reed-bed-wastewater-treatment.aspx#. [13] Weedon, C.M., Vertical down-flow Constructed Wetlands - Towards optimal wastewater treatment, Articol prezentat la Conferina Constructed Wetland Association AquaEnviro, Londra, 2012.

    Ing. Dipl. Mircea-Vlad Muresan Universitatea Tehnic din Cluj-Napoca

    [email protected] Prof. univ. Dr. chim. Elena Maria PIC Universitatea Tehnic din Cluj-Napoca

    [email protected]

    232