Fluke Clamp MetersSolutions for every need
7/29/2019 3363537_6115_ENG_A_W.PDF
2/6
Job functions Applications
Electrical Contractor Working on panels and branch circuits
Measureloadsonabranchcircuitatapanel(includingfeedercables,branch circuits, and neutrals) and the continuity of switches, fuses, andcontacts
MeasureloadsidevoltageofabreakerorfuseCheckifacircuitislivebeforebeginningwork
Facility Maintenance
Commercial Electrician
Commercial Electrical Contractor Verify circuit integrity and operation
Measureloadcurrent,acvoltageandcontinuityofswitches,fuses,andcontacts
Feeder Cables
CheckbalanceandloadingoffeedercablesIndustrial Electrical Contractor
Plant Maintenance
Electrical Contractor Working with motors and drives
Measuremotorstart-upandruncurrentMeasuretheoutputofvariablespeedmotorsanddrives
In and around the service panel
Clamparoundbusbarorconductorstomeasureloadsandlinefrequencircuits and feeders
Measure ac or dc current
Measureacordcforuseinbattery-operatedsystemslikeUPSorothersystems
Commercal Electrician
Plant Maintenance
Industrial Electrician
Industrial Service Electrician Service panel, service entrance, and low voltage vaults
Intheservicepanel,clamparoundeachindividualphase.(Goodforlarsingle or parallel conductors)
Intheserviceentrance,clamparoundbusbars,upto2.5in,toverifyexpected current usage
Measurecurrentinconductorsoflow-voltagevaults(1000Vorless)
Working with large loads
Verifyoperationoflargeloadservicepanels,switchgears,largecurrenDC systems, and motors
Electrical Contractor
Electric Utility Technician
Marine or Welding Electrician
Facility MaintenanceElectrician
HVAC/R Service Technician Checking boilers and furnaces
Capturefluegastemperaturesandperformflamerodtesting
HVAC Motors and drives
MeasurestartandrunmotorcapacitorsTroubleshootcompressorelectricalmotorfaultsMeasureperformanceofvariablefrequencydrives
Testing electrical performance
Measureload-sideandsupply-sidecurrentandvoltageMeasurecurrentandvoltagephasebalanceon3phasesystems
Clamp Meter selection chart
7/29/2019 3363537_6115_ENG_A_W.PDF
3/6
features Recommended Clamp
enJawaccurrentmeasurementto100AandDCvoltage-600:CATIII600Vac/dc-1000:CATIII1000Vac/dc,CATIV600Vac/dc
ntinuity,resistanceggedandeasytouse
T5-1000
CAT III 1000 V
Others in thefamily: T5-600
asureupto400Aac1Aresolutioninthe40Arangeformore
ecise measurmentsmpactformfactortomakemeasurmentseasilytight cable compartmentsasureacanddcvoltageto600Vsistance,continuity,anddisplayholdfunctions
322
CAT III 600 V
Others in thefamily: 321
ushcurrentmodeforrepeatablemeasurementmotororequipmentstart-upcurrentrrow,elongatedjawwithlargeopeningeasilygles out the conductor of intereste-rmstomoreaccuratelymeasuretheactualrent, even with distorted wave-forms causednoisy loadsludeslargebacklitdisplay,frequency,acanddctage, resistance, continuity, and min/max
337
CAT III 600 V
Others in thefamily: 333, 334,335 and 336
to2000Adc,1400Aaccurrentmeasurementgejawsuitableforsingleormultiplelarge
nductorsIV600Vratedformaximumapplication
rsatilityutsfor600Vac,1000Vdc,400K resistance,d continuitywpassfilter,min/max/avg,andinrushcurrentcuratelymeasurefrequencyofcurrentandtage up to 1 kHz
355
CAT IV 600 V,CAT III 1000 V
Others in thefamily: 353
asurecurrentupto600Aacandupto 0 A dcasuretrue-rmsvoltage,capacitance,resistance,d continuityasurecontacttemperaturewithincludedpe-K temperature probe. (Or measure theside temperature of a pipe with the 80PK-8e Clamp Temperature Probe (sold separately))
902
600 V CAT III
Speciality clamp meters
Job functions
Facility Maintenance
Electrician
Hospital Electrician
Electrical Contractor
Industrial/Commercial
Maintenance Electrician
Utility Technician
Electrical Contractor/Consultant
Process Technician/
Electrician
Automation Specialist/
Commercial Electrician
Electrical and Field
Service Technician
HVAC/R Technician
Electrical Engineer
Commercial Electrician
Facility Maintenance
Electrician
Electric Utility Engineer
7/29/2019 3363537_6115_ENG_A_W.PDF
4/6
Need more help choosing a clamp meter to fit your needs? Go interactive!
Visit www.fluke.com/clamps and use our on-line selection guide to
find the right clamp solution for you!
*Not available for sale in Canada
ications Key features Recommended Clamp
suring leakage current
eckinsulationconditionandleakageofcircuitsandstemseckforleakageincircuitsandsystemsutilizingfilters
ing insulation on live circuits
aluateinsulationconditiononlivecircuitsvialeakagerrent measurements where disconnection is highlyonvenient
Measurementofleakagecurrentwith3mArangeand1 A of resolution, for accurate monitoring of insulationerosion
Broadrangeofmeasurement,from1Aupto60A,for
all installation needsAdvancedshieldingtoensureaccurateresultswhen
measuring near other conductorsEasy-to-carry,pocket-sizedleakagecurrenttesterwith
wide 40 mm (1.5 in) jaw size
360*
CAT III 300 V
unding and bonding resistance testing
formgroundlooptestsinareaswhereothergroundistancetesttechniquesarenotavailablestpartsofamulti-groundedsystemriodicallyperformquicktestsonsystemgroundsas
rt of a regular preventative maintenance program
Measurefrom0.025 to 1500 ground loop resistance.Largejawforclampingaroundthewidestrangeof
ground conductors or grounding barsMeasuregroundleakageandacloadcurrentsfrom
0.2 mA all the way up to 30 A
Userdefinedalarmlimitsforrapidpass/failtypemeasurments
1630
CAT III 300 V
suring process control signals
asures4-20mAsignalswithoutbreakingtheloopeckcorrectoperationofPLCsandcontrolsystemsalog I/O
Savestimeandmoneybyeasilymeasuring4-20mAsignals
DetatchableminiatureclampfortightlocationsAlsomeasureolder10to50mAsignalsystemswiththe
100 mA rangeBacklitdisplay,spotlight,displayhold,andzeroreading
buttons
771
CAT II 300 V
suring non-linear loads
tupandtroubleshootvariablefrequencydrivesandS systemsVerify correct operation by measuring keywerqualityparameters
monic measurements
coverharmonicissuesthatcandamageordisruptticalequipment
ubleshooting start-up current issues
eckstart-upcurrentwherespuriousresetsorisance circuit breaker tripping occurs
d studiesrifyelectricalsystemcapacitybeforeaddingloads
AC/DCcurrent:Clamp-onmeasurementofcurrentupto1400 A ac rms and 2000 A dc
Highestsafetyrating:CATIV600Vratedforuseattheservice entrance
Accurateinnoisyenvironments:Usinglow-passfilter,theclamp meter performs even with distorted waveforms
Datalogging:Identifyintermittentfaultsbylogginganypowerqualityparameterforminutes,oroveramonth
Troubleshootharmonics:Analyzeandlogharmonicsdigitally or graphically
Inrushcurrent:Captureandanalyzenuisancetripping,
from 3 seconds to 300 seconds
345
CAT IV 600 V,CAT III 1000 V
7/29/2019 3363537_6115_ENG_A_W.PDF
5/6
Clamp meters designed for the way you work.
See our full line of Fluke Accessories
at www.fluke.com/accy-catalog
Commercial/industrialelectrician
Residential/commercialelectrician
General purpose
T5-600 T5-1000 321 322 333 334 335
Measurements
AC current
AC volts
Resistance
Continuity
DC Volts
DC current
True-rms
Frequency
Min/Max/Avg
4-20 mA (0.01 mA resolution)
Temperature
Capacitance
Earth ground loop resistance
Special features
Inrush current mode
Low Pass filter
Harmonics, power,and data logging
Display
Display hold
Backlight
Graphing display
Specifications
Jaw opening 12.9 mm (0.5 in) 12.9 mm (0.5 in) 25.4 mm (1.0 in) 25.4 mm (1.0 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2
Max wire size 1/0 THHN Cable 1/0 THHN Cable 500 MCM 500 MCM 750 MCM 750 MCM 750 MCM
Current range ac rms 0 to 100 A 0 to 100 A 0 to 400 A 0 to 400 A 0 to 400 A 0 to 600 A 0 to 600
Accuracy ac current (50/60 Hz) 3 % 3 counts
3 % 3 counts
1.8 % 5 counts
1.8 % 5 counts
2 % 5 counts
2 % 5 counts
2 % 5 count
AC Response Averaging Averaging Averaging Averaging Averaging Averaging True-rms
Current range dc
Accuracy dc current
Voltage range ac 0 to 600 V 0 to 1000 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600
Accuracy ac voltage 1.5 % 2 counts
1.5 % 2 counts
1.2 %+ 5 counts
1.2 %+ 5 counts
1 %+ 5 counts
1 %+ 5 counts
1 %+ 5 count
Voltage range dc 0 to 600 V 0 to 1000 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600
Accuracy dc voltage 1 % 1 count
1 % 1 count
1 %+ 5 counts
1 %+ 5 counts
1 %+ 5 counts
1 %+ 5 count
Resistance range 0 to 1000 0 to 1000 0 to 400 0 to 400 0 to 600 0 to 6000 0 to 6000
Frequency measurement range
Unit power
Auto off
Warranty and safety
Warranty (years) 2 2 2 2 3 3 3
Category ratings (EN61010-1) CAT III 600 V CAT IV 600 V,CAT III 1000 V
CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600
7/29/2019 3363537_6115_ENG_A_W.PDF
6/6
Fluke CorporationPO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.PO Box 1186, 5602 BDEindhoven, The Netherlands
Fluke. Keeping your world up and running.
For more information call:In the U.S.A. (800) 443-5853 orFax (425) 446-5116In Europe/M-East/Arica +31 (0) 402675 200 or Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE orFax (905) 890-6866
From other countries +1 (425) 446-5500 orFax +1 (425) 446-5116Web access: http://www.luke.com
2008 Fluke Corporation.Specifcations subject to change without notice.Printed in U.S.A. 8/2008 3363537 B-EN-N Rev A
Modification of this document is not permittedwithout written permission from Fluke Corporation.
Industrial electrician HVAC/R High end industrial, utility Leakage Process Earth ground Power quality
337 902 353 355 360* 771 1630 345
m (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 58 mm (2.3 in) 58 mm (2.3 in) 40 mm (1.5 in) 4.5mm (0.177 in) 35 mm (1.38 in) 58 mm (2.3 in)
CM or two0 MCM
750 MCM or two500 MCM
750 MCM 750 MCM or three500 MCM
750 MCM or three500 MCM
1250 MCM 6 AWG 1000 MCM 750 MCM or three500 MCM
600 A 0 to 999.9 A 0 to 600 A 0 to 1400 A 0 to 1400 A 0 to 60 A 0 to 35 A 0 to 1400 A
2 %counts
2 % 5 counts
2 % 5 counts
1.5 %+ 5 counts
1.5 %+ 5 counts
1 %+ 5 counts
2 % 3 counts
3 % 5 counts
e-rms True-rms True-rms True-rms True-rms Averaging True-rms True-rms
600 A 0 to 999.9 A 0 to 200 A 0 to 2000 A 0 to 2000 A 0 to 99.9 mA 0 to 2000 A
2 %counts
2 %+ 3 counts
1 % 5 counts
1.5 %+ 5 counts
1.5 %+ 5 counts
4-20 mA is 0.2 %+ 5 counts
1.5 % 5 counts
600 V 0 to 600 V 600 V 0 to 600 V 0 to 825 V
%counts
1 %+ 5 counts
1 % 5 counts
1 %+ 5 counts
1 % 5 counts
600 V 0 to 600 V 0 to 600 V 0 to 1000 V 0 to 825 V
%counts
1 %+ 5 counts
1 % 5 counts
1 %+ 5 counts
1 % 5 counts
6000 0 to 6000 0 to 9999 0 to 400 K 0 to 1500
5 to 400 Hz 5 to 1000 Hz 5 to 1000 Hz 15 to 1000 Hz
3 3 3 3 3 1 3 1 2
II 600 V CAT III 600 V CAT III 600 V CAT IV 600 V,CAT III 1000 V
CAT IV 600 V,CAT III 1000 V
CAT III 300 V Cat II 300 V CAT III 300 V CAT IV 600 V,CAT III 1000 V