74
USPP_DC001_E1_1 ZXUN USPP Basic Data Configuration

5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Embed Size (px)

DESCRIPTION

USPP

Citation preview

Page 1: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

USPP_DC001_E1_1ZXUN USPP Basic Data Configuration

Page 2: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Targets

Master Data Configuration Flow Master OMM Access Configuration Master Physical Data Configuration Master UDS Configuration Master Administration Domain Data Configuration Master Data Transfer

Page 3: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Contents

Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer

Page 4: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

ZXUN USPP Configuration Flow

Page 5: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Contents

Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer

Page 6: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

OMM Access Configuration

Flow of OMM Access Configuration1. Loading the License File

2. Creating a USPP

3. Creating a Network Element Agent

4. Starting a Network Element Agent

5. Updating USPP

6. Validating the License

7. Uploading the License to OMM Server

8. Adding a Network Element on OMM

9. Adding a USPP Physical Office

10. Loading the Schema

Page 7: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Loading the License File

1. On the NetnumenTM M31 main window, select menu Views > License Management.

2. On the License tab, select the NetNumen node.

3. On the License Detail Info tabe, click the (Update License Info) button.

4. Select the License file and click Open.

Page 8: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Loading the License File

Page 9: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Creating a USPP

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select the NetNumen node.

3. On the MML commands navigation tree, select USPP CONFIGURATION MANAGEME

NT > USPP NODE CONFIGURATION MANAGEMENT > CREATE USPP (CREATE U

SPP).

Page 10: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Creating a Network Element Agent

1. On the NetnumenTM M31 main window, select menu Views > Topology Management.

2. On the Physical View tab, right-click the NetNumen node and then select Create NE Agent from the pop-up menu.

Page 11: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Creating a Network Element Agent

Page 12: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Starting a Network Element Agent

1. On the NetnumenTM M31 main window, select menu Views > Topology Management.

2. On the Physical View tab, right-click the NE agent under the NetNumen node, and then select NE Agent Management > Start from the pop-up menu.

Page 13: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Updating USPP

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal to ope

n the MML Terminal window.

2. Select the NetNumen node.

3. On the MML commands navigation tree, select USPP CONFIGURATION MANAGEME

NT > USPP SNO MANAGEMENT > SHOW USPP SNO to open the SHOW USPPSNO

command interface.

4. Click the Execute(F5) button or press F5 to query the latest version of the OMM.

5. On the MML commands navigation tree, select USPP CONFIGURATION MANAGEME

NT > USPP SNO MANAGEMENT > UPDATE USPP to open the command interface s

hown in the following figure.

Page 14: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Validating the License

1. On the NetNumen(TM) M31 main window, select menu Views > License Management.

2. On the License tab, select the NetNumen node.

3. On the License Detail Info tab, click the (License Info Enable) button.

Page 15: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Uploading the License to OMM Server

1. On the NetNumen(TM) M31 main window, select menu Views > License Management.

2. On the License tab, select the NetNumen node.

3. On the License Detail Info tab, click the (License Info Synchronization) button.

Page 16: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Network Element on OMM

1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.

2. Select root from the NetNumen navigation tree.

3. On the MML Commands navigation tree, select System Maintenance > Net Element

Configuration > Create Management Configuration (ADD NE).

Page 17: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a USPP Physical Office

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select the NetNumen node.

3. On the MML commands navigation tree, select USPP CONFIGURATION MANAGEME

NT > USPP NE CONFIGURATION MANAGEMENT > ADD USPPNE (ADD USPPNE).

Page 18: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Loading the Schema

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select menu Operation > Batch.

3. Click the (Import File) button to select and import the batch commands file of Schema.

4. Click the (Run Batch) button to execute the commands in batch.

Page 19: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Loading the Schema

5. Perform the following operations to confirm the loading.① Select NetNumen > USPP > Device Configuration > Public Device Configuration.

② On the MML commands navigation tree, select MML Commands > UDS Dev Configuration > Show UDS Dev > Show Schema Version Configuration (SHOW SCHVER).

③ Click the Execute(F5) button or press F5 to execute this command, confirm that the latest version is what has been uploaded.

Page 20: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Contents

Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer

Page 21: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Physical Data Configuration Flow

Page 22: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Rack

1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.

2. Select the current working office node under root.

3. On the MML commands navigation tree, select MML Commands > Device Configurat

ion > Physical Configuration > Rack Configuration > Create Rack (ADD RACK).

Page 23: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Shelf

1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.

2. Select the current working office node under root.

3. On the MML commands navigation tree, select MML Commands > Device Configurat

ion > Physical Configuration > Shelf Configuration > Create SHELF (ADD SHELF)

to open the window shown in the following figure.

Page 24: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Unit

The sequence to create units and modules is as follows.1. Add the UIMC unit.

2. Add modules other than OMP and RPU.

3. Add units other than UIMC.

Page 25: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Unit

1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.

2. Select the current working office node under root.

3. On the MML commands navigation tree, select MML Commands > Device Configuration > Physical Configuration > Unit Configuration > Create Unit (ADD UNIT).

Page 26: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Module

1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.

2. Select the current working office node under root.

3. On the MML commands navigation tree, select MML Commands > Device Configurat

ion > Physical Configuration > Module Configuration > Create Module (ADD MOD

ULE).

Page 27: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Configuring TCP Transfer for TIPI

1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.

2. Select the current working office node under root.

3. On the MML commands navigation tree, select MML Commands > Device Configurat

ion > Physical Configuration > TCP Transmit Configuration > Create TCP Transmi

t (ADD TCPTRANS).

Page 28: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Setting the IP of the OMP module

1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.

2. Select the current working office node under root.

3. On the MML commands navigation tree, select MML Commands > Device Conf

iguration > Global Data Configuration > Modify Global Data OMP Informatio

n (SET OMP).

Page 29: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Service Server Node

1. On the NetNumen(TM)M30 main window, select menu Views > MML Terminal.

2. Select the current working office node under root.

3. On the MML commands navigation tree, select MML Commands > Device

Configuration > Server Node Configuration > Back Server > Create Back Server

(ADD BACKSVR).

Page 30: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Setting the Connection Between a Service Server Node and the OMM

1. On the NetNumen(TM)M30 main window, select menu Views > MML Terminal.

2. Select the current working office node under root.

3. On the MML commands navigation tree, select MML Commands > Device

Configuration > Server Node Configuration > Back Server Node Configuration >

Create Back Server Node Configuration (ADD HSERV).

Page 31: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Contents

Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer

Page 32: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

UDS Configuration Flow

Page 33: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Database Node1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration. (USPP here is a USPP node created by the CREATE USPP command).

3. On the MML commands tree, select MML Commands > UDS Dev Configuration > Database Node Configuration > Create Database Node Configuration (ADD DBNODE).

Page 34: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a DSA Node

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands navigation tree, select MML Commands > UDS Dev Configuration > DSA Node Configuration > DSA Node Configuration > Create DSA Node Configuration (ADD DSANODE).

Page 35: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Setting DSA Node Options

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Node Configuration > DSA Node Option Configuration (SET DSANODEOPT).

Page 36: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Setting DSA Node Storage Configuration

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal to open the MML Terminal window.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Node Configuration > DSA Node Storage Configuration > Create DSA Node Storage Configuration (ADD DSANODESAV).

Page 37: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a DSA

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands navigation tree, select MML Commands > UDS Dev Configuration > DSA Configuration > DSA Configuration > Create DSA Configuration (ADD DSA).

Page 38: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a DSA Member

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands navigation tree, select MML Commands > UDS Dev Configuration > DSA Configuration > DSA Member Configuration > Create DSA Member Configuration (ADD DSACLU).

Page 39: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Setting DSA Options

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands navigation tree, select MML Commands > UDS Dev Configuration > DSA Configuration > DSA Option Configuration > Modify DSA Option Configuration (SET DSAOPT).

Page 40: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding Subscriber Table Capacity

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Configuration > DSA Subscriber Capacity Configuration > Create DSA Subscriber Capacity Configuration (ADD CAPSUB).

Page 41: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding an ID DSA Group

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal to open the MML Terminal window.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Group Configuration > IDSA Group Configuration > Create IDSA Group Configuration (ADD IDDSAGRP).

Page 42: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Distributing Numbers to an ID DSA

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Group Configuration > IDSA Distributing Configuration > Create IDSA Distributing Configuration (ADD IDSAMAP).

Page 43: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a P DSA Group

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Group Configuration > PDSA Group Configuration > Create PDSA Group Configuration (ADD DSAGRP).

Page 44: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Setting UDS Load Control

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands tree, select MML Commands > UDS Dev Configuration > Load Control Configuration > Modify Load Control Configuration (SET LOADLEV).

Page 45: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Setting UDS Parameters

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands tree, select MML Commands > UDS Dev Configuration > UDS Parameter Configuration > UDS Parameter Configuration > Modify UDS Parameter Configuration (SET UDSPARA).

Page 46: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Setting UDS Parameters

Page 47: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Setting the Capacity of a Configuration Table

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands tree, select MML Commands > UDS Dev Configuration > UDS Parameter Configuration > CM Table Capacity Configuration > Modify CM Table Capacity Configuration (SET CAPCFG).

Page 48: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Setting the Capacity Scale of a Subscriber Data Table

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.3. On the MML commands tree, select MML Commands > UDS Dev Configuration > UD

S Parameter Configuration > Subscriber Table Capacity Scale Configuration > Modify Subscriber Table Capacity Scale Configuration (SET CAPSUBSCL).

Page 49: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a DUA Node

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.

3. On the MML commands tree, select MML Commands > FE/Provision Configuration > Create FE/Provision Configuration (ADD DUANODE).

Page 50: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Monitoring Center

1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.3. On the MML commands tree, select MML Commands > CC Resource Configuration

> Create CC Resource Configuration (ADD DMCC).

Page 51: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Contents

Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer

Page 52: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Administration Domain Data Configuration

The Flow of Administration Domain Configuration

Page 53: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding an Administration Domain

1. On the Netnumen(TM) M31 main window, select menu Views > MML Termin

al.

2. Select NetNumen > USPP > Service Configuration > Public Service Confi

guration.

3. On the MML commands navigation tree, select MML Commands> dminDom

ain Basic Configuration > AdminDomain Configuration > Create AdminD

omain Configuration( ADD VHLR).

Page 54: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding an Administration Domain

Page 55: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Configuring Relation Between Administration Domain and DUA

1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML commands navigation tree, select MML Commands > AdminDomain Ba

sic Configuration > AdminDomain Relating DUA Configuration > Create AdminD

omain Relating DUA Configuration(ADD VDUA).

Page 56: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding Administration Domain Function

1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML commands navigation tree, select MML Commands > AdminDomain Ba

sic Configuration > AdminDomain Function Switch Configuration > Create Admi

nDomain Function Switch Configuration(ADD VHLRLIC).

Page 57: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding Administration Domain Capacity

1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML commands navigation tree, select MML Commands > AdminDomain Bsic Configuration > AdminDomain Capacity Configuration > Create AdminDomain Capacity Configuration(ADD VHLRCAP).

Page 58: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Configuring Relation Between PDSA Group and Administration Domain1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > PDSA Group–AdminDomain Relation Configuration > Create PDSA Group–AdminDomain Relation Configuration (ADD VDSAGRP).

Page 59: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Physical Number Segment for an Administration Domain 1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > AdminDomain Physics Number Distributing Configuration > Create AdminDomain Physics Number Distributing Configuration (ADD VHLRSPN).

Page 60: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding a Logical Number Segment for an Administration Domain1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > AdminDomain Logical Number Distributing Configuration > Create AdminDomain Logical Number Distributing Configuration (ADD VHLRSLN).

Page 61: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Distributing a Physical Number Segment to an ID DSA Group 1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > IDSA Group Physics Number Distributing Configuration > Create IDSA Group Physics Number Distributing Configuration (ADD IDSAGSPN).

Page 62: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Distributing a Logical Number Segment to an ID DSA Group1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > IDSA Group Logical Number Distributing Configuration > Create IDSA Group Logical Number Distributing Configuration (ADD IDSAGSLN).

Page 63: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Distributing a Physical Number Segment to a P DSA Group1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > PDSA Group Logical Number Distributing Configuration > Create PDSA Group Logical Number Distributing Configuration (ADD DSAGRPSPN).

Page 64: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding an Agent Number Segment Group

1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML Commands navigation tree, select Agent Resource Configuration > Agent Number Group Configuration > Create Agent Number Group Configuration(ADD NUMGRP).

Page 65: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding an Agent Physical Number Segment

1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML Commands navigation tree, select Agent Resource Configuration > Agent Physical Number Segment Configuration > Create Agent Physical Number Segment Configuration(ADD AGENTSPN).

Page 66: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding an Agent Logical Number Segment

1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.

2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.

3. On the MML Commands navigation tree, select Agent Resource Configuration > Agent Logical Number Segment Configuration > Create Agent Logical Number Segment Configuration(ADD AGENTSLN).

Page 67: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding an Operator Role

1. On the Netnumen(TM) M31 main window, select menu Views > Security Management.

2. Select Role Management from the Security Tree.

3. Click the (Create Role) button to open the Create Role dialog box.

4. On the Basic Information tab, Set Role Name and Role Description.

5. On the Access Rights tab, set rights.

Page 68: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding an Operator Role

Page 69: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding an Operator

1. On the Netnumen(TM) M31 main window, select menu Views > Security Management.

2. Select User Management from the Security Tree.

3. Click the (Create User) button.

Page 70: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Adding an Operator

Page 71: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Contents

Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer

Page 72: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Uploading OMM Configuration Data

1. On the NetNumen(TM)M30 HLR main window, select menu Views > MML Terminal.

2. Select the current working office node under root.

3. On the MML commands navigation tree, select MML Commands > Data

Maintenance > Data Transfer > Sync Data (Only Used By Admin) (SYNA).

Page 73: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74

Uploading EMS Configuration Data

1. On the Netnumen(TM) M31 main window, select menu Views > Daily Maintenance.

2. Select Daily Maintenance > USPP > Data Maintenance > Data Sync from the navigation tree.

Page 74: 5 ZXUN USPP(HLRe) BC en Commissioning and Debugging(Basic Data Configuration) 3 PPT 201008(Draft) 74