9326 d2Uv2 NodeB Product Description V2.0 Sep08

Embed Size (px)

Citation preview

  • Alcatel-Lucent 9326 digital 2U

    V2 Node B

    Product Description

    _________________________________________________________________________________________

    Document Number: UMT/BTS/INF/024277 Document Issue: 02.00 / EN Document Status: Standard Date of Issue: 29/SEP/2008

    _________________________________________________________________________________________

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 2 / 33

    Copyright 2008 by Alcatel-Lucent Technologies. All Rights Reserved.

    About Alcatel-Lucent

    Alcatel-Lucent (Euronext Paris and NYSE: ALU) provides solutions that enable service

    providers, enterprises and governments worldwide, to deliver voice, data and video

    communication services to end-users. As a leader in fixed, mobile and converged broadband

    networking, IP technologies, applications, and services, Alcatel-Lucent offers the end-to-end

    solutions that enable compelling communications services for people at home, at work and on

    the move. For more information, visit Alcatel-Lucent on the Internet: http://www.alcatel-

    lucent.com.

    Notice

    The information contained in this document is subject to change without notice. At the time

    of publication, it reflects the latest information on Alcatel-Lucents offer, however, our policy

    of continuing development may result in improvement or change to the specifications

    described.

    All the photos and drawings are not contractual and can change without notice.

    Trademarks

    The following trademarks are used throughout this document:

    Alcatel-Lucent, Alcatel, Lucent Technologies and their respective logos are trademarks and

    service marks of Alcatel-Lucent, Alcatel and Lucent Technologies.

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 3 / 33

    CONTENTS

    1 INTRODUCTION ................................................................................................6

    1.1 OVERVIEW..................................................................................................... 6 1.2 SCOPE OF THIS DOCUMENT ..................................................................................... 6

    2 PRODUCT OVERVIEW..........................................................................................7

    2.1 TARGET CONTEXT ............................................................................................. 7 2.2 PHYSICAL OVERVIEW ........................................................................................... 7

    2.2.1 Main Characteristics............................................................................... 7 2.2.2 Layout ............................................................................................... 8 2.2.3 External Dimensions ............................................................................... 9 2.2.4 Weight ............................................................................................... 9

    3 PRODUCT DESCRIPTION .................................................................................... 10

    3.1 ICCM-U .....................................................................................................11 3.1.1 ICCM-U Interfaces.................................................................................11 3.1.2 Dimensions .........................................................................................11 3.1.3 ICCM-U Face Plate ................................................................................12

    3.2 CHANNEL ELEMENT MODULE (ICEM-U)........................................................................13 3.2.1 ICEM-U Interfaces .................................................................................13 3.2.2 Dimensions .........................................................................................13 3.2.3 ICEM-U Face Plate ................................................................................14

    3.3 XCCM-U.....................................................................................................15 3.3.1 xCCM-U Interfaces ................................................................................15 3.3.2 Dimensions .........................................................................................16 3.3.3 xCCM-U Face Plate................................................................................16

    3.4 CHANNEL ELEMENT MODULE (XCEM-U) .......................................................................16 3.4.1 xCEM-U Interfaces ................................................................................16 3.4.2 Dimensions .........................................................................................16 3.4.3 xCEM-U Face Plate ................................................................................17

    3.5 RBP .........................................................................................................17 3.6 RUC.........................................................................................................18 3.7 POWER SYSTEM...............................................................................................18 3.8 CONTROL UNIT ...............................................................................................19 3.9 OPTIONS .....................................................................................................19 3.10 ENVIRONMENTAL AND REGULATORY REQUIREMENTS .........................................................19

    3.10.1 General .............................................................................................19 3.10.2 Operation Temperature and Humidity.........................................................22 3.10.3 Acoustic Noise .....................................................................................22 3.10.4 Vibration ...........................................................................................22 3.10.5 Shock................................................................................................22 3.10.6 Ingress Protection.................................................................................22 3.10.7 Regulatory Requirements........................................................................22 3.10.8 Safety...............................................................................................22 3.10.9 EMC .................................................................................................23 3.10.10 Ecology..........................................................................................23

    4 EVOLIUM INTEGRATION .................................................................................... 24

    4.1 MAXIMUM GSM CONFIGURATION SUPPORTED....................................................................25 4.1.1 Indoor...............................................................................................25 4.1.2 Outdoor.............................................................................................25

    5 POWER SUPPLY UNITS INTEGRATION .................................................................... 26

    5.1 MAIN CHARACTERISTICS .......................................................................................27

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 4 / 33

    6 APPENDIX A: RELATED READING.......................................................................... 29

    6.1 EMC DOCUMENTS ............................................................................................29 6.2 SAFETY DOCUMENTS ..........................................................................................29 6.3 ENVIRONMENTAL DOCUMENTS .................................................................................29 6.4 POWER SUPPLY ...............................................................................................30 6.5 SITE SPECIFICATION ...........................................................................................30 6.6 ECOLOGY.....................................................................................................30 6.7 GSM ENGINEERING DOCUMENTS ...............................................................................30 6.8 POWER SUPPLY UNITS DOCUMENTS ............................................................................30

    7 APPENDIX B: PUBLICATION HISTORY..................................................................... 31

    8 APPENDIX C: GLOSSARY & ACRONYMS................................................................... 32

    8.1 GLOSSARY....................................................................................................32 8.2 ACRONYMS ...................................................................................................32

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 5 / 33

    LIST OF FIGURES

    Figure 1 - Shelf Overview (1) ................................................................................................... 7 Figure 2 Layout (1) ............................................................................................................. 8 Figure 3 back view (1) ......................................................................................................... 8 Figure 4 - External Dimensions (1)............................................................................................. 9 Figure 5 - d2U in Node B ......................................................................................................10 Figure 6 - iCCM-U adaptation for V2 form factor ..........................................................................12 Figure 7 - iCCM-U Face Plate .................................................................................................12 Figure 8 - iCEM-U adaptation for V2 form factor ..........................................................................14 Figure 9 - iCEM-U face plate..................................................................................................14 Figure 10 - xCCM-U Face Plate ...............................................................................................16 Figure 11 - xCEM-U face plate................................................................................................17 Figure 12 - RBP Front View ...................................................................................................17 Figure 13 - RUC face plate(1) .................................................................................................18 Figure 14 - Air Flow............................................................................................................19 Figure 15 - d2U in Restricted Environment.................................................................................20 Figure 16 - d2U in Unrestricted Environment ..............................................................................21 Figure 17 d2U integration within MBI5 ....................................................................................24 Figure 18 Small Outdoor Power Supply unit ..............................................................................26 Figure 19 Medium Outdoor Power Supply unit ...........................................................................27

    LIST OF TABLES

    Table 1 - Weight of Main Items ............................................................................................... 9 Table 2 - Power Consumptions ...............................................................................................18 Table 3 Indoor GSM Cabinets ...............................................................................................25 Table 4 Outdoor GSM Cabinets .............................................................................................26

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 6 / 33

    1 INTRODUCTION

    1.1 Overview

    This document describes the specifications of the Alcatel-Lucent 9326 digital 2U V2 Node B

    (d2U V2) for iModules and xModules.

    For more information on feature availability, please refer to the Feature Planning Guide,

    Baselines and Release Notes.

    1.2 Scope of this Document

    The Alcatel-Lucent d2U Product Description covers the high level description of the digital

    base station, as well as a description of the main modules. Alcatel-Lucent has a full portfolio

    of UMTS Node B, including:

    - the macro range (9311 Macro Node B Indoor, 9311 Macro Node B Outdoor),

    - the 9326 digital 2U V2 Node B (d2U V2) and associated Remote Radio Heads (9341 RRH20-

    21, 9341 RRH40-21, 9341 RRH40-08, 9341 RRH40-19, 9341 RRH40-AWS and future) or Radio

    Compact Node B (rCompact),,

    - the 9313 Micro Node B,

    - the 9314 Pico Node B.

    This document only covers the d2U V2 equipped with iModules (iCCM-U and iCEM-U) adapted

    to the V2 rack form factor and the xModules (xCCM-U and xCEM-U).

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 7 / 33

    2 PRODUCT OVERVIEW

    2.1 Target Context

    The d2U offers a cost-effective entry into the UMTS market for areas where site selection is

    difficult. It is particularly suited for fast deployment in the user space of existing Node B or in

    existing standard 19 inch racks. This Digital Node B can be used with the Radio cabinet (9332

    rCompact) or Remote Radio Head (9341 RRH20-21, 9341 RRH40-21, 9341 RRH40-08, 9341

    RRH40-19, 9341 RRH40-AWS and future).

    2.2 Physical Overview

    2.2.1 Main Characteristics

    Figure 1 - Shelf Overview (1)

    The d2U has been specifically designed for coverage within constrained environments:

    Dense areas where site acquisition is difficult for a regular size macro Node B.

    Easier site deployment due to its low volume: no need to add a base station on the

    site, installation is possible within a user space.

    It can be deployed in indoor environments (standard 19 inch rack or 2G Evolium

    cabinets) and outdoor environments (2G Evolium cabinets or Power supply units).

    This Digital Node B can be used with the Radio cabinet (rCompact) or Remote Radio

    Head (9341 RRH20-21, 9341 RRH40-21, 9341 RRH40-08, 9341 RRH40-19, 9341 RRH40-

    AWS and future).

    This Digital Node B uses the same W-CDMA Module features, repackaged to 19 inch

    dimensions (iCCM2, iCEM2-128, xCCM, xCEM, GPSAM, OIM). Note that the iCCM-U /

    xCCM-U modules provide more functionality than (respectively) the iCCM/xCCM as they

    also incorporate the functionality of the GPSAM and interface to remote radios (OIM).

    (1) Photo not contractual.

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 8 / 33

    2.2.2 Layout

    The layout of the d2U is displayed in Figure 2 and 3.

    Figure 2 Layout (1)

    Figure 3 back view (1)

    (1) Photos not contractual.

    iCEM-U

    iCCM-U

    Fans (x2)

    RUC

    RBP

    xCEM-U

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 9 / 33

    2.2.3 External Dimensions

    The external dimensions of the d2U are (HxWxD) 88.1mm (2U) x 482.6mm (19 inches) x

    300mm as shown below.

    Figure 4 - External Dimensions (1)

    2.2.4 Weight

    The weights of the main components are as follows:

    Individual Weight System Shipping

    Item lbs kg Qty lbs kg

    19 inches subrack + RBP + RUC + Fans 11.9 5.4 1 11.9 5.4

    Filler 3.75 1.7 2..0 3.75 1.7

    iCCM-U/xCCM-U 2.2/2.58 1/1.17 1 2.58 1.17

    iCEM-U/xCEM-U 2.2/3.3 1/1.5 1..3 9.9 4.5

    Total (fully configured)

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 10 / 33

    3 PRODUCT DESCRIPTION

    Figure 5 - d2U in Node B

    The d2U consists of four types of hardware boards:

    CCM which controls OAM management, part of call processing and internal/external

    data flow switching/combining, supporting external/internal alarm connectivity and

    external synchronization reference interface. The two types of CCM boards are usable;

    i.e. iCCM-U adapted to the V2 form factor and xCCM-U. A single CCM-U (either iCCM-U

    or xCCM-U) can be used inside a d2U V2 Node B.

    CEM, controls part of call processing and base band transmit/receive digital signal

    processing. One, up to a maximum three, of these modules can be inserted in the

    dNode B 2U V2. The two types of CEM boards are usable; i.e. iCEM-U adapted to the V2

    form factor and xCEM-U. Mixed configurations are also supported.

    RBP (user Rack Back Plane), supports all internal links between CCM-U and CEM-U

    modules.

    RUC (Rack User Commissioning), which supports all commissioning of non-volatile

    memories, and fan alarms.

    The d2U V2 can be added in the user space of any Node B or in a standard 19 inch indoor rack,

    when the environmental conditions are compliant with the requirements detailed in the Site

    Specification document [A10].

    Sector

    Sector

    RF feeders

    : -

    RNC

    d2U

    i/xCCM-U i/xCEM-U Iub

    RRH RRH RRH

    RUC

    -48VDC

    LPPCM (Option)

    EAM

    Customer Alarms

    or rCompact

    (Option)

    Sector

    Sector

    RRH ....

    -48VDC power supply

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 11 / 33

    3.1 ICCM-U

    The iCCM-U board provides the following features:

    Network interfaces : 8 E1/T1 (Iub connectivity),

    o 16x16 PCM Switch

    o ATM TC Layer

    o 1 IMA groups,

    Internal interfaces (HSSL) for iCEM-U boards,

    Base band samples routing and summing,

    ATM plane support,

    CPU power to manage the Node B terminated flows,

    Node B synchronization,

    O&M functions,

    Simple drop and insert functions.

    GPSAM features, by collecting the information about the state of the d2U (alarms,

    inventory and commissioning);

    OIM features to support up to three optical links.

    3.1.1 ICCM-U Interfaces

    2 x Ethernet debug ports, 1 x 10BT and 1 x 10/100 BT;

    2 RS232 debug ports;

    3 HSSL/CPRI interfaces with SFP connection;

    10MHz output reference clock based on the OVCXO 52fc, sinus wave 10dBm PPS in

    connector;

    1 RS485 GPS/UCPS link;

    7 segment display showing the synchronization mode;

    1 Ethernet backhaul port with SFP connection;

    1 RJ45 port for external alarms

    Various LED indications.

    3.1.2 Dimensions

    The iCCM-U is a 21mm face plate board. PCB dimensions are 389.6mm x 223.6mm. It is

    mandatory to add an adaptation board at the back of the module and to change the front

    plate to be compatible with the V2 form factor. Once modified the Code of the module is

    changed.

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 12 / 33

    Figure 6 - iCCM-U adaptation for V2 form factor

    3.1.3 ICCM-U Face Plate

    Figure 7 - iCCM-U Face Plate

    Leds

    2x

    Ethernet

    Extracting

    hole

    PCM

    E1/T1

    3 Optical

    SFP cages

    Alarm

    GPS

    Synchro

    10MHz

    ref

    100Bfx

    SFP cages

    New face

    plate

    Adaptation board

    to be added to the

    iCCM-U module

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 13 / 33

    3.2 Channel Element Module (ICEM-U)

    The iCEM-U board can be divided in three main functional blocks:

    The Interface & Control Unit (ICU);

    The Base Band Unit 1 (BBU1);

    The Base Band Unit 2 (BBU2) for more processing power.

    With the following functional split:

    The ICU (Interface and Control Unit) performs:

    The physical data interface functions for the entire CEM;

    The call processing functions (NBAP) of the CEM;

    The OAM functions of the CEM;

    Base Band signal processing of some common channels.

    The BBU (Base Band Unit) performs :

    All transmit and receive base band signal processing functions: layer 1 functions of

    the UMTS radio network.

    3.2.1 ICEM-U Interfaces

    1 x Ethernet debug port 1 x 10/100 BT;

    1 RS232 debug port, on the same connector as Ethernet;

    Multiple synchronization signals (from/to PDCP_RX, U2_TX FPGA);

    Various LED indications.

    3.2.2 Dimensions

    The iCEM-U is a 21mm face plate board. PCB dimensions are 389.6mm x 223.6mm. It is

    mandatory to add an adaptation board at the back of the module and to change the front

    plate to be compatible with the V2 form factor. Once modified the Code of the module is

    changed.

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 14 / 33

    Figure 8 - iCEM-U adaptation for V2 form factor

    3.2.3 ICEM-U Face Plate

    Figure 9 - iCEM-U face plate

    Leds

    Ethernet Synchro

    Extracting

    hole

    New face

    plate

    Adaptation board

    to be added to the

    iCEM-U module

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 15 / 33

    3.3 xCCM-U

    The xCCM-U is an enhanced version of the iCCM-U. It provides increased processing

    capabilities to adapt the Node B to the evolution of the last mile connectivity using state of

    the art hardware and software components. The xCCM-U board is composed of a main board

    and an MDA (Media Dependent Adaptor), allowing for future evolutions and support of

    additional backhauling options.

    The xCCM-U board provides the following features:

    Network interfaces :

    o 8 E1/T1 (ATM Iub connectivity) 4 on mother board, 4 on MDA

    16x16 PCM Switch

    ATM TC Layer

    2 IMA groups (optional feature),

    o 1 FE (Fast Ethernet) port (IP Iub connectivity)

    Internal interfaces (HSSL) for iCEM-U/xCEM-U boards,

    Base band samples routing and summing,

    ATM plane support,

    CPU power to manage the Node B terminated flows,

    Node B synchronization,

    O&M functions,

    Simple drop and insert functions.

    GPSAM features, by collecting the information about the state of the d2U (alarms,

    inventory and commissioning);

    OIM features to support up to six optical links.

    3.3.1 xCCM-U Interfaces

    2 x E1 connectors (4E1s each, one on mother board, one on MDA)

    1 x 100 BT connector for SiteLAN or debug

    1 x 100BT connector for IP Iub backhaul

    3 CPRI interfaces with SFP connection

    3 CPRI or HSSL interfaces with SFP connection

    10MHz output reference clock based on the OVCXO 52fc, sinus wave 10dBm PPS in

    connector;

    1 RS485 GPS/UCPS link

    1 RJ45 port for external alarms

    Two LEDs (one green, one red) are used to indicate the status of the module

    One bi-color LED (green or red) is used to indicate the activity status of the board

    Twelve tri-colour LEDs are used to indicate the status of synchronisation and of E1

    links.

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 16 / 33

    3.3.2 Dimensions

    The ixCCM-U is a 21mm face plate board. PCB dimensions are 389.6mm x 273.0mm.

    3.3.3 xCCM-U Face Plate

    Figure 10 - xCCM-U Face Plate

    3.4 Channel Element Module (xCEM-U)

    The two main functional elements of the xCEM-U are:

    The base-band units (BBU), which perform all of the base-band signal processing

    functionality for each of the UMTS channels supported, and,

    The interface and control unit (ICU), which provides the data, control and timing

    interfaces to the Base Station. It also performs xCEM-U control and management

    functions.

    Compared to the previous CEM generations, the xCEM-U provides:

    High capacity on a single board (capacity of iCEM-U doubled)

    Support of R99, HSDPA and HSUPA on a single board

    Support of 6 cells and 2 frequencies

    High flexibility in board configuration

    Future capacity increase via Multi-mode BBU through optimized software only.

    Future proof architecture with upgrade capability towards HSPA+ and LTE

    3.4.1 xCEM-U Interfaces

    1 x Ethernet debug port 1 x 10/100 BT;

    1 RS232 debug port, on the same connector as Ethernet;

    Multiple synchronization signals (from/to PDCP_RX, U2_TX FPGA);

    Various LED indications.

    3.4.2 Dimensions

    The xCEM-U is a 21mm face plate board. PCB dimensions are 389.6 mm x 273 mm.

    Leds Extracting

    hole PCM

    E1/T1

    6 Optical

    SFP cages Alarm

    GPS

    Synchro

    10MHz

    ref 2x

    Ethernet

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 17 / 33

    3.4.3 xCEM-U Face Plate

    Figure 11 - xCEM-U face plate

    3.5 RBP

    The d2U V2 houses one iCCM-U modified or xCCM-U and up to three iCEM-U modified and/or

    xCEM-U. The Rack Back Plane (RBP) is part of the d2U and allows the signalling

    interconnections between the CCM-U and the CEM-U modules inserted within the digital shelf.

    The backplane board also gives a power supply to the CCM-U and CEM-U modules. The

    transmitted signals are:

    Base Band links : HSSL between CCM-U and CEM-U;

    -48V power supply;

    Dallas bus for remote inventory;

    Presence detect for modules.

    The RBP has also its own signals:

    Dallas bus for remote inventory;

    Backplane identification;

    Module slot identification.

    Figure 12 - RBP Front View

    Leds Ethernet Synchro Extracting

    hole

    Hight frequenciesconnection

    Power connectors for CEM-U

    Digital connector

    Power connectorfor CCM-U

    Imput Power connector

    Hight frequenciesconnection

    Power connectors for CEM-U

    Digital connector

    Power connectorfor CCM-U

    Imput Power connector

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 18 / 33

    3.6 RUC

    The Rack User Commissioning (RUC) manages the following functionalities:

    Power filtering,

    Current limitation,

    Commissioning,

    Inventory,

    Fan alarms report and power supply,

    DC power supply connectivity,

    Figure 13 - RUC face plate(1)

    (1) Photo not contractual.

    3.7 Power System

    The d2U operates with -48 VDC power supply in accordance with [A9].

    The nominal DC voltage range is 40,5VDC to -57VDC. Within the nominal voltage range, the

    d2U operates at full performance. The d2U will not suffer any irreversible damage when

    powered within an abnormal voltage within the range -0 VDC to -40,5 VDC and -57VDC to -60

    VDC.

    Configuration Max DC power

    Consumption

    Typ DC power

    Consumption

    iCCM-U + 1 iCEM-U 107W 90W

    iCCM-U + 2 iCEM-U 152W 129W

    iCCM-U + 3 iCEM-U 197W 168W

    xCCM-U + 1 xCEM-U 167W 145W

    xCCM-U + 2 xCEM-U 244W 207W

    xCCM-U + 3 xCEM-U 321W 269W

    Table 2 - Power Consumptions

    Power

    filter

    Alarms

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 19 / 33

    3.8 Control Unit

    Two fans are integrated to the digital shelf to cool the boards. As shown, the cooling air path

    within the shelf is:

    1. Air enters on the right side of the shelf;

    2. The air is drawn through the shelf to cool boards;

    3. It is exhausted on the left side of the shelf.

    Figure 14 - Air Flow

    3.9 Options

    Several options are supported by the product:

    Number of CEM-U (from one to three). In case some CEM-U are not used, they have to

    be replaced by fillers.

    External alarms kit (16 external alarms can be managed by the d2U) - requires 1U

    additional free space.

    PCM Lightning Protection kit - requires 1U additional free space.

    Standard standalone Installation cables.

    Specifics kit for the integration in GSM Evolium cabinets.

    3.10 Environmental and Regulatory Requirements

    3.10.1 General

    The cabinet is designed to operate under climatic condition described by [A5], Class 3.2,

    except for:

    High temperature: +65C;

    Icy conditions;

    High absolute humidity: 36g/m3.

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 20 / 33

    The d2U is manufactured according to WEEE (Waste of Electrical and Electronic Equipment)

    and RoHS (Restriction of Hazardous Substances) recommendations.

    3.10.1.1 d2U in restricted environment

    The environmental boundary conditions for d2U standalone deployment are:

    Air inlet and outlet shall be free of any blockage across the full height of the

    module (see figures below in green)

    Maximum inlet (right hand side) air temperature of +60 C

    Pressure drop generated by the air inlet and outlet shall not be greater than

    5 Pa @ 120m3/h

    Air inlet and

    outlet

    Figure 15 - d2U in Restricted Environment

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 21 / 33

    3.10.1.2 d2U in unrestricted environment

    The environmental boundary conditions for d2U standalone deployment are:

    Air inlet and outlet shall be free of any blockage across the full height of the module

    (see below in green)

    Maximum inlet (right hand side) air temperature of +65 C

    Pressure drop generated by the air inlet and outlet shall not be greater than 5 Pa @

    120m3/h

    Figure 16 - d2U in Unrestricted Environment

    Air inlet and

    outlet 40 40

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 22 / 33

    3.10.2 Operation Temperature and Humidity

    The total operational temperature range of the d2U is 5C/+65C.

    The rack shall be compatible with sitting at locations where the surrounding air may have a

    high moisture content as describe by [A5]:

    Relative humidity: +8% to +100%

    Absolute humidity: 0.03 g/m3 to 36 g/m3

    3.10.3 Acoustic Noise

    The maximum d2U sound power levels emitted in accordance with [A7] are the following:

    LwAd = 56 dB(A) at 25C

    3.10.4 Vibration

    Once fully installed, the d2U meets the requirements of [A6], class 3M5.

    3.10.5 Shock

    Once fully installed, the d2U meets the requirements of [A6], class 3M5.

    3.10.6 Ingress Protection

    The d2U shelf is weather resistant to prevent ingress of rain, snow, dust, and other solid

    foreign objects to a minimum level of IP20 as specified by [A4].

    3.10.7 Regulatory Requirements

    For Europe, the standards mentioned below are part of mandatory standards to obtain CE

    Mark under European EMC directive 89/336/EEC and new European EMC Directive

    2004/108/EC.

    3.10.8 Safety

    The d2U is designed to meet the following Safety Regulatory standards:

    For European deployment: [A3].

    For North America deployment: [A16] and [A17].

    For deployment in others countries or regions: [A2].

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 23 / 33

    3.10.9 EMC

    The d2U meets the following EMC standards:

    For European deployment: [A1].

    For North America deployment: [A18].

    For deployment in others countries or regions: [A19].

    3.10.10 Ecology

    The cabled cabinet is compliant to WEEE [A11] and RoHS [A12] directives.

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 24 / 33

    4 EVOLIUM INTEGRATION

    Integration of the d2U is possible in the following GSM cabinets (MBI5, CIDE, CIMA, MBO1,

    MBO2, MBO1E, MBO2E, COME, CODE). Nevertheless, because the d2U is integrated in one of

    the subrack in MBI5 - MBO1 and MBO1E, the modules initially in this subrack must be moved to

    other positions and single-TRX may be replaced by Twin-TRX in order to maintain the previous

    number of carriers. For more information, please refer to Engineering document [A13].

    Figure 17 d2U integration within MBI5

    D2U

    GSM

    Modules

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 25 / 33

    4.1 Maximum GSM configuration supported

    The maximum GSM configurations supported when the d2U is integrated in the 2G cabinets are

    the followings.

    4.1.1 Indoor

    DC AC Cabinet

    Initial Final with

    Single TRX Final with

    Twin TRX Initial Final with

    Single TRX Final with

    Twin TRX

    Up to 12 8 12 Up to 12 8 12

    Up to 6/6 4/4 6/6 Up to 6/6 4/4 6/6

    MBI5

    Up to 4/4/4 3/3/3 4/4/4 Up to 4/4/4 3/3/3 wo BATS 4/4/4

    Up to 12 8 12 Up to 8 8 wo BATS

    Up to 6/6 4/4 6/6 Up to 2/2 2/2 wo BATS

    Medi G4 (CIDE)

    Up to 4/4/4 3/3/3 4/4/4 Up to 2/2/2 2/2/2 wo BATS

    Up to 12 8 12

    Up to 6/6 4/4 6/6

    Medi G3 (CIMA)

    Up to 4/4/4 3/3/3 4/4/4

    Table 3 Indoor GSM Cabinets

    4.1.2 Outdoor

    Cabinet Initial Final with

    Single TRX Final with

    Twin TRX

    Up to 8 4 8

    Up to 4/4 2/2 4/4

    G4 Evol MBO1E

    Up to 2/2/2 1/1/1 2/2/2

    Up to 12

    Up to 6/6

    G4 Evol MBO2E

    Up to 4/4/4

    No change

    Up to 8 4 8

    Up to 4/4 2/2 4/4

    G4 MBO1

    Up to 2/2/2 1/1/1 2/2/2

    Up to 12

    Up to 6/6

    G4 MBO2

    Up to 4/4/4

    No change

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 26 / 33

    Up to 12

    Up to 6/6

    G4 Medi COME

    Up to 4/4/4

    No change

    Up to 12

    Up to 6/6

    G4 Medi CODE

    Up to 4/4/4

    No change

    Table 4 Outdoor GSM Cabinets

    5 POWER SUPPLY UNITS INTEGRATION

    Integration of the d2U V2 is possible in the Small and Medium Outdoor Power supply unit. For

    more information, please refer to Small d2U Outdoor Power Supply unit Product description

    [A14] and Medium d2U Outdoor Power Supply unit Product description [A15].

    Figure 18 Small Outdoor Power Supply unit

    d2U

    PCM LP

    External Alarm module

    Power Unit

    Batteries

    Controller

    Rectifiers

    Inputs / Outputs

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 27 / 33

    Figure 19 Medium Outdoor Power Supply unit

    5.1 Main characteristics

    The main characteristic of the Outdoor Power supply units are the followings:

    Small Medium

    Dimensions (HxWxD)

    - w/o plinth

    - With Plinth

    740x581x586mm

    890x581x586mm

    N/A

    1500x820x700mm

    Net Weight with plinth 66 kg 174kg

    Ingress Protection IP55 IP55

    Operating temperature range -40C+50C (+55C

    under conditions)

    -40C+50C (+55C

    under conditions)

    Number of RRH supported by the

    PSU

    Up to 3 Up to 6

    User space 4U (d2U room) 8U + 5U (Top d2U

    room)

    d2U

    PCM LP

    External Alarm module

    Power Unit

    Batteries

    Inputs / Outputs

    User space or

    Second battery

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 28 / 33

    Supported options - PCM LP or RETA

    - Ext Alarms

    - PCM LP or RETA

    - Ext Alarms

    - 7705 SAR

    - 2nd battery shelf or

    Microwave

    Battery back up time - Up to 2 hours for

    d2U + 3 RRH

    - Up to 8 hours for

    d2U + 3 RRH

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 29 / 33

    6 APPENDIX A: RELATED READING

    For further information please refer to:

    6.1 EMC Documents

    [A1] ETSI EN 300 386: Electromagnetic compatibility and Radio spectrum Matters (ERM);

    Telecommunication network equipment; ElectroMagnetic Compatibility (EMC)

    requirements.

    [A18] 47 CFR Part 15 - RADIO FREQUENCY DEVICES

    [A19] CISPR 22 - Limits and methods of measurement of radio disturbance characteristics

    of information technology equipment

    6.2 Safety Documents

    [A2] IEC 60950-1 Information Technology Equipment Safety Part1: General

    Requirements, Ed.1 2001.

    [A3] EN 60950-1 Information Technology Equipment Safety Part1: General

    Requirements, Ed.1 2001.

    [A16] CAN/CSA C22.2 No.60950-01 Information Technology Equipment Safety Part1:

    General Requirements

    [A17] UL 60950-1 Information Technology Equipment Safety Part1: General

    Requirements

    6.3 Environmental Documents

    [A4] IEC 60529 Degrees of Protection Provided by Enclosure, (IP code) Ed.2.1 2001.

    [A5] ETS 300 019-2-3 Equipment Engineering (EE); Environmental conditions and

    environmental tests for telecommunications equipment; part 2-3: classification of

    environmental conditions stationary use at weather protected locations: class 3.2,

    except for:

    High temperature: +65 C,

    Condition of icing

    High absolute humidity (36g/m3)

    [A6] ETS 300 019-1-3, Environmental Engineering (EE); Environmental conditions and

    environmental tests for telecommunications equipment; Part 1-3: Classification of

    environmental conditions; Stationary use at weather protected locations.

    [A7] ISO 7779 Acoustic: Measurement of Airborne Noise emitted by computers and

    business equipment.

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 30 / 33

    6.4 Power Supply

    [A9] ETS 300 132-2 Power supply interface at the input to telecommunications

    equipment; Part 2: Operated by direct current (DC).

    6.5 Site Specification

    [A10] IM 06-0406 UMTS dNode B 2U Site Specification.

    6.6 Ecology

    [A11] Directive 2002/96/EC of 27 January 2002 on waste electrical and electronic

    equipment (WEEE)

    [A12] 2002/95/EC Directive 2002/95/EC of 27 January 2003 on the restriction of the use of

    certain hazardous substances in electrical and electronic equipment (RoHS)

    6.7 GSM Engineering documents

    [A13] Engineering rules for configuration (TBD)

    6.8 Power Supply Units documents

    [A14] Small S6 Outdoor enclosure (MIFR)

    [A15] Medium Outdoor enclosure (TBD)

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 31 / 33

    7 APPENDIX B: PUBLICATION HISTORY

    29/FEB/2008

    Issue 01.00/EN, Preliminary

    Creation

    11/APR/2008

    Issue 01.01/EN, Preliminary

    New Photos

    Weight updated

    21/APR/2008

    Issue 01.02/EN, Preliminary

    Power consumptions updated

    29/SEP/2008

    Issue 02.00/EN, Standard

    Main characteristics of the Small and Medium Power Supply units

    Minors corrections

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 32 / 33

    8 APPENDIX C: GLOSSARY & ACRONYMS

    8.1 Glossary

    Node B A logical node responsible for UMTS radio transmission/reception in one or more cells

    to/from the User Equipment.

    Iub Interface between a Node B and an RNC.

    8.2 Acronyms

    This section provides a list of the terms and acronyms used within this document.

    1111 ---- 10101010 2U 3.5 inch

    3GPP Third Generation Partnership

    Project

    A A A A ---- EEEE ATM Asynchronous Transfer Mode

    BBU Base Band Unit

    BTS Base Station Transceiver

    Subsystem

    CCM Alpha version of iCCM

    CEM Alpha version of iCEM

    CPRI Common Public Radio Interface

    DBP Digital Back Plane

    dBTS Digital BTS

    DC Direct Current (Power source)

    E1 Standard European PCM link

    nickname

    EMC Electro-Magnetic Compatibility

    EMI Electro-Magnetic Interference

    G G G G O O O O GPS Global Positioning System

    GPSAM GPS/Alarm Module

    GPxOIM GPSAM + Xoim

    GSM Global System for Mobile

    HSDPA High Speed Downlink Packet

    Access

    HSSL High Speed Serial Link

    HW Hardware

    ICCM-U Specific module with function of

    GPSAM, CCM and OIM

    ICEM-U Specific Icem128 module

    ICU Interface Control Unit

    IEC International Electro-technical

    Committee

    IMA Inverse Multiplexing for ATM

    IP Ingress Protection

    ISO International Standards

    Organization

    OAM Operation Administration and

    Maintenance

    OEM Original Equipment

    Manufacturer

    OIM Optical Interface Module

  • 9326 DIGITAL 2U V2 NODE B PRODUCT DESCRIPTION SEPTEMBER 2008

    Document Number: UMT/BTS/INF/024227 | Document Issue: 02.00 / EN | Document Status: Standard

    Alcatel-Lucent Proprietary

    See Notice on Page 2 3 / 33

    P P P P ---- Z Z Z Z PCM Pulse Code Modulation

    RBP Rack Back Plane

    rBTS Radio BTS

    RNC Radio Network Controller for

    UMTS

    RoHS Restriction of Hazardous

    Substance

    RRH Remote Radio Head

    RUC Rack User Commissioning

    SFP Small Form-factor Pluggable

    SW Software

    T1 Standard US PCM system

    (1.544Mbit/s)

    UL Underwriters Laboratories

    UMTS Universal Mobile

    Telecommunication System

    UTRAN UMTS Terrestrial Radio Access

    Network

    WEEE Waste Electrical and Electronic

    Equipment

    xCCM-U 2nd generation of CCM module

    with function of GPSAM, xCCM

    and OIM

    xCEM-U Specific xCEM module with 256

    channel elements