52
BOQ for Financial Bid NAME OF WORK : CONSTRUCTION OF THE BSVS, BUILDING (Ground + 2), AT SHEOHAR, BLOCK SHEOHAR WARD NO.03, THANA NO. 163, KHATA NO. 2311, KHESARA NO. 2086 SHEOHAR-843329. EMPLOYER BANK OF BARODA THE ASST. GENERAL MANAGER, BANK OF BARODA, REGIONAL OFFICE, MUZAFFARPUR REGION, PATNA ZONE, Krishna Honda Building, 2nd floor, Akharaghat Road, Muzaffarpur-842001. Tel- 0621-2224011 Email- [email protected] [email protected] ARCHITECT YASHWANT KUMAR Asha-9B Avenue South Park, Bistupur, Jamshedpur-831001. Tel-0657-232091, 9431932201

BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

BOQ for Financial Bid

NAME OF WORK : CONSTRUCTION OF THE BSVS, BUILDING (Ground + 2),

AT SHEOHAR, BLOCK SHEOHAR WARD NO.03, THANA NO. 163, KHATA NO. 2311, KHESARA NO. 2086 SHEOHAR-843329.

EMPLOYER

BANK OF BARODA

THE ASST. GENERAL MANAGER, BANK OF BARODA, REGIONAL OFFICE, MUZAFFARPUR REGION, PATNA ZONE,

Krishna Honda Building, 2nd floor, Akharaghat Road, Muzaffarpur-842001.

Tel- 0621-2224011 Email- [email protected]

[email protected]

ARCHITECT

YASHWANT KUMAR

Asha-9B Avenue South Park, Bistupur, Jamshedpur-831001.

Tel-0657-232091, 9431932201

Page 2: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

SL No Description Unit Quantity Rate Amount

1 Earth Excavation :-Earth work in

excavation in foundation trenches (not

exceeding 1.5 m in width or 10 sqm on

plan) including dressing of sides and

ramming of bottoms, lift upto 1.5 m .

including getting out the excavated soil

and disposal of surplus excavated soil as

directed, within a lead of 50 m.

All Kinds of Soil Cum 1792.0

2 Ploughing the existing ground for tie beam

& fin to a depth ot 15 cm to 25 cm and

watering the same

All kinds of soil. sqm 39.0

3 Re felling of soil:- Filling available

excavated earth (excluding rock) in

trenches, plinth,of foundations etc. in

layers not exceeding 20 cm in depth:

consolidating each deposited layer by

ramming and watering lead.

cum 1728.0

4 Sand filling:- Supplying and Filling in

plinth 610mm & 50mm Th Sand filling in

footing trench and level with local sand

and under floors including, watering,

ramming consolidating and dressing

complete.

cum 143.0

5 Brick flat Soiling in Foundation :-

Providing designation 100 B one brick flat

soling in foundation trench & below tie

beam joints filled with local sand including

cost of watering, taxes, royalty all complete

as per building specification and direction

of E/l.

sqm 211.0

6 P.C.C In Foundation:- Providing and 1.4.8 (1 Cement :4 coarse sand :8 graded

stone aggregate 40 mm nominal size)

cum 11

B.O.Q FOR CIVIL ,ELECTRICAL & SANITATION WORK IN B.S.V.S AT SHEOHAR,

B.O.B,MUZAFFARPUR REGION

SUB HEAD A ( CIVIL WORK IN BUILDING) ,GROUND ,1St & 2nd FLOOR )

Section 1(Footing & Other work up to Plinth

Page 3: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

7 Providing and laying in position machine

batched, machine mixed and machine

vibrated design mix cement concrete of

specified grade for reinforced cement

concrete structural elements, excluding the

cost of centring, shuttering finishing and

reinforcement, M-20 grade reinforced

cement concrete.

1:1:5:3(1 cement: 1.5 coarse sand:3

graded stone aggregate 20 mm nominal

size)

All work upto plinth level cum 76

Brick work

8 250mm Th Brick work with bricks of class

designation 100A above tie beam up to

plinth in :Cement mortar 1:6 (1 cement: 6 coarse

sand )cum 23

9 D.P.C :- Providing and laying damp-proof

Course 50 mm thick with cement concrete

1:2:4(1cement:2:2 coarse sand :4 graded

stone aggregate 20mm nominal size)sqm 23

10 Extra for providing and mixing water

prodding material in cement concrete work

in the proportion mixing cement concrete

in mixer with 5% Cisco or any other water

proffing compound as per building

specification and direction of E/I.Note-

Mixing water proofing material @1Kg/ bag

of cement.

per 50 kg

cement/1

bag

cement

@1Kg

cisco

5.5

11 Centring and shuttering:- Centring and

shuttering including strutting, propping etc.

up to plinth level and removal of form for.

Foundations, footings, bases of columns

etc. for mass concrete.sqm 39

Lintels, beams, plinth beams, girders,

ressumers and cantilevers.sqm 50

Columns, Pillars, Piers, Abutments, Posts

and Strutssqm 76

12 Reinforcement in footing,column & Tie

beam up to plinth LevelReinforcement for R.C.C. work including

straightening, cutting, bending, placing in

position and binding all complete.

Thermo-Mechanically Treated bars TMTC-

500-8mm dia.kg 21

Thermo-Mechanically Treated bars TMTC-

500-10mm dia.kg 362

R.C.C work in Footing , Tie beam & Column up to P.L

Page 4: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

Thermo-Mechanically Treated bars TMTC-

500-12mm dia.kg 1709

Thermo-Mechanically Treated bars TMT

Fe-500-I6mrn dia.kg 192

Brick work

13 250mm Th Brick work with bricks of class

designation 100A above plinth up to 1St

Floor Level in :

Cement mortar 1:6 (1 cement: 6 coarse

sand )cum 64

14 125mm Th Half brick masonry with bricks

of class designation 100A above plinth

up to 1St floor Level in :

Cement mortar 1:4 (1 cement: 4 coarse

send)sqm 153

15 Extra for providing and placing in position

2 Nos, 6 mm dia , MS bars at every third

course of half brick masonry.sqm 153

16 Providing and laying in position machine

batched, machine mixed and machine

vibrated design mix cement concrete of

specified grade for reinforced cement

concrete structural elements, excluding the

cost of centring, shuttering finishing and

reinforcement, M-20 grade reinforced

cement concrete. 1:1:5:3(1 cement: 1.5

coarse sand:3 graded stone aggregate 20

mm nominal size)

All work above plinth level(Walls columns,

pillars, posts cind struts)cum 9.5

Beams, planth beams, girders,

bressumers, contilevers,Suspended floors

lintels roofs and staircases including spiral

staircases, shelves etc

cum 102

17 Centring & Shuttering :- Centring and

shuttering including strutting, propping

etc.above plinth up to floor level and

removal of form for.Suspended floors, roofs, landings,

balconies and access platform.sqm 256

Lintels beam,roof beams, and cantilevers.sqm 59

Columns, Pillars, Piers, Abutments, Posts

and Strutssqm 142

Stairs,(excluding landings) except spiral-

staircases.sqm 9.5

Total Section l :-

Section ll (Super structure at Ground floor above plinth Lev)

R.C.C work in Column ,Lintel beam & Chhaja ,Roof beam & roof Slab up

Page 5: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

Chhaja ,Perdi, Vertical and horizontal fins

individually or forming box louvers band,

facias and eaves boardssqm 6

18 Reinforcement for R.C.C. work including

straightening, cutting, bending, placing in

position and binding all complete.

Thermo-Mechanically Treated bars TMTC-

500-8mm dia.kg 1462

Thermo-Mechanically Treated bars TMTC-

500-10mm dia.kg 855

Thermo-Mechanically Treated bars TMTC-

500-12mm dia.kg 449

Thermo-Mechanically Treated bars TMT

Fe-500-I6mrn dia.kg 312

Mild steel 6.0 mm dia in Cannopy kg 74

Finishing work

Cement plaster in course sand

19 20mm Th Cement plaster with course

sand on outer wall from G.L to 1St Floor

Level in 1:6 cement mortar(1

cement: 6 coarse sand)

sqm 329

20 12mm Th Cement plaster with course

sand on inner wall , window sill & copla

from P.L to 1St Floor Level in 1:6 cement

mortar (1

cement: 6 coarse sand)

sqm 885

21 6mm Th Cement plaster in ceiling

1:4 cement mortar(1 cement : 4 coarse

sand)

sqm 289

Painting

22 Applying one coat of white cement primer

of approved brand and manufacture on

exterior wall surface:

sqm 328

23 Finishing walls with water proofing cement

paint(Snowcem) of approve brand and

manufacture and of required shade to give

an even shade new work (Three or more

coat).

sqm 328

24 Distempering with dry distemper of

approved brand and manufacture

(Ashian/Berger/) two or more coats and of

required shade on new work ,over and

including primimn coat of whiting to given

an even shade.

sqm 1174

25 Applying priming coat with ready mixed

aluminum primer of approved brand and

manufacture on resinous wood and

plywood.

sqm 64

Reinforcement in column,Lintel beam,Stair roof beam & roof slab up to 1St

Page 6: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

26 Painting with synthetic enamel paint of

approved brand and manufacture with

enamel putty in all shades to give an even

shade New wood work (two or more coats)

sqm 64

27 With ready mixed zinc chromate yellow

primer of approved brand and manufacture

on steel galvanized iron/steel workssqm 39

28 Painting with synthetic enamel paint of

approved brand and manufacture with

enamel putty in all shades to give an even

shade New steel work (two or more coats)

sqm 39

Flooring work

29 Brick Flat soiling :- Providing designation

100 B one brick flat soling joints filled with

local sand including cost of watering,

taxes, royalty all complete as per building

specification and direction of E/l,

sqm 233.0

30 P.C.C Flooring:- 40mm Th cement

concrete flooring 1:2:4(1Cement:2

Coarse:4 Grade stone aggregate)finished

with a floating coat of neat cement

including cement slurry etc.

sqm 233

31 Skirting :- 18mm Th Cement plaster

skirting (up to 15 Cm height) with cement

mortar 1:3(1Cement : 3 coarse sand )

finished with a floating coat of neat cement

.

sqm 27.5

32 Ceramic Floot tile in Toilet :- Providing

and laying Ceramic glazed floor tiles

300x300 mm (thickness to be specified by

the manufacturer) of ist quality conforming

to IS : 15622 of approved make in colours

such as white , Ivory , Grey , Fume Red ,

Brown , laid on 20 mm thick Cement motar

1:4 (1 cement: 4 coarse sand ) including

pointing the joints with white cement and

matching pigment etc., complete.

sqm 24

Page 7: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

33 Ceramic wall tile for Dado :- Providing

and fixing 1st quality ceramic glazed wall

tiles conforming to IS : 15622 (Thickness

to be specified by the manufacture) of

approved make in all colours, shades

except burgundy , bottle green , black of

any size as approved by Engineer-in-

charge in dados over 12 mm thick bed of

cement Motar 1:3(1 cement: 3 coarse sand

) and jointing with grey cement slurry @

3.3 kg per sqm including pointing in white

cement mixed with pigment of matching

shade complete.

sqm 68

Door & Window

34 Collapsible door :- Providing and fixing in

position collapsible steel shutters with

vertical channes 20x10x2 mm and braced

with flat iron diagonals 20x5 mm size with

top and bottom rail of T-tron 40x40x6 mm

with 40 mm dia steel pulleys complete with

bots.nuts locking arrangement stoppers

handies including applying a priming coat

of approved steel primer.

sqm 11

35 Door chowkhat :-Providing and fixing

pressed steel door frame confirming IS

code 351 manufactured from commerical

mild steel sheet of 1.25 mm thickness

including hinges, jamb, lock jamb, bead

and if required angle threshold of mild

steel angle of section 50 x 25 mm or base

ties of 1.25mm pressed mild steel welded

or rigidly fixed together by . mechnical

means, adjustable lugs with split end tail to

each jamb including steel butt hinges 2.5

mm thick with mortar guards, lock strike-

plate and shock absorbers as specified

and applying a coat of approved steel

primer after pre-treatment of the surface as

directed by Engineer-in-charge:

Profile C

meter 16.5

Page 8: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

36 Door Shutter:-Providing and fixing 35mm

Th flush door shutters non-decorative

type,core of block board construction with

frame of 1 st class hard wood and well

matched commercial 3 ply veneering with

vertical grains or cross bands and face

veneers on both faces of shutters.

including anodized aluminum butt hinges

with necessary screws.

sqm 32

37 Extra for providing lipping with 2nd class

teak wood battens 25 mm minimum depth

on all edges of shutters (overall area of

door shutter to be measured)

sqm 32

38 Extra for providing vision panel not

exceeding 0.1 sqm in Director

chamber,Adm Office,Guest facuilty, of

flush doors (cost of glas excluded),

sqm 1

39 Providing and fixing 85mmx42mm oxidised

M.S. pull bolt lock conforming to IS:7534

with necessary screws bolts nut and

washers etc. complete

each 8.5

40 providing 40x5 mm flat iron hold fast 40 cm

long including fixing to frame with 10 mm

diameter bots,nuts and wooden plugs and

embeddings in cement concrete block

30x10x15 cm 1:3:6 mix (1 cement :3

coarse sand :6 graded stone aggregate 20

mm nominal size)

each 184

41 Providing and fixing oxidised M.S.tower

bolt 150x10mm black finish in toilet,(barrel

type) with necessary screws etc.completeeach 13

42 Providing and fixing bright finisned brass

100mm mortice latch and lock with 6 lever

handles with necessary screws etc.

complete.(best make of approved quality)

,Director chamber, Adm

office,guest faculity& Library.

each 4

43 Providing and fixing bright finished brass

hangging type floor door stoper with

necessary screws etc. compelte.

each 8

44 Providing and fixing IS:3564 bright finished

brass hydraulic door closer (best make of

approved quality) with necessary

accessories and screws etc.

coplete.Director Chamber & Facuilty room.

each 2

45 Providing and fixing 125 mm long

M.S.handles with necessary screws

etc.complete

Each 61

Page 9: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

46 Window grill :- Providing and fixing M.S.

grills of requirement pattern in frames of

windows etc. with M.S. flats bars 5mm Th

& 20mm wide or 10mm x 10mm square

bars @ 100mm C/C Vertical /horizontal

etc.all complete, fixed to openings/wooden

frames with rawl plugs screws etc.

kg 60

47 Steel glazed window :- Providing and

fixing steel glazed windows and ventilatrs

of standard rolled steel sections, joints

mitered and welded with 15x3 mm lugs 10

cm long with steel lugs embedded in

cement concrete blocks 15x10x10 cm of

1:3:6(1 cement: 3 coarse sand : 6 graded

stone aggregate 20 mm nominal size) or

with woodenplugs and screws or rawl

plugs and screws or with fixing clips or

with bolts and nuts as required, including

providing and fixing of glass panes with

glazing clips and special metal-sash putty

of approved make complete including

applying a priming coat of approved steel

primer; excluding the cost of metal beading

and other fitting except necessary hinges

or pivots as required.

Sqm 40

48 Providing and fixing M.S.fan clamp type 1

of 16 mm dia.M.S. bar bent to shape with

hooked ends in R.C.C slabs during laying

including painting the exposed portion of

loop,all as per standard design complete.

each 23

49 Providing and fixing circular cast iron box

for ceiling fan clamp 140 mm internal dia,

73 mm height, 5 mm thick rim bottom and

top lids, 1.5 mm thick M.S sheet with its

top surface hacked for proper bonding top

lid shall be screwed into the cast iron box

by means of 3.3 mm dia round headed

screws, one ;pcf at the corners. Clamps

shall be made of 12 mm dia M.S. bar bent

to shape as per standard drawing.

each 23

50 Steel work welded in built up

sections/framed work including cutting

hoisting, rixing in position and applying a

priming coat of approved steel primer

using structural steel, etc. as required. M.S

Baluster 10mmx10mmx900mm each steps

,mild steel flats bar 25mmx5mm over

baluster.

kg 35

Page 10: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

51 Providing and fixing hand rail G.I Pipes 40

mm normal bore by welding etc. to steel

ladder railings & staircases railing

including applying a priming coat of

approved steel primer . In

stringers, treads landings etc. of stair

cases.

kg 90

52 Making 0.45M Wide plinth protection

50mm thick of cement concrete 1:3:6 (1

cement :3 coarse sand : 6 graded stone

aggregate 20 mm nominal size) over

75mm thick bed of dry brick ballast 40 mm

nominal size, well rammed and

consolidated and grouted with fine sand

including finishing the top smooth.

sqm 38

Brick work

53 250mm Th Brick work with bricks of class

designation 100A at 1St Floor Level in :

Cement mortar 1:6 (1 cement: 6 coarse

sand )cum 52

54 125mm Th Half brick masonry with bricks

of class designation 100A above plinth

up to 1St floor Level in :

Cement mortar 1:4 (1 cement: 4 coarse

send)sqm 76

55 Extra for providing and placing in position

2 Nos, 6 mm dia , MS bars at every third

course of half brick masonry.sqm 76

56 Providing and laying in position machine

batched, machine mixed and machine

vibrated design mix cement concrete of

specified grade for reinforced cement

concrete structural elements, excluding the

cost of centring, shuttering finishing and

reinforcement, M-20 grade reinforced

cement concrete.

1:1:5:3(1 cement: 1.5 coarse sand:3

graded stone aggregate 20 mm nominal

size)

All work above plinth level(Walls columns,

pillars, posts cind struts)cum 7

57 Beams, planth beams, girders,

bressumers, contilevers,Suspended floors

lintels roofs and staircases including spiral

staircases, shelves etc

cum 75

Section lll (Super structure at 1St floor Level

Total Section ll:-

R.C.C work in Column ,Lintel beam & Chhaja ,Roof beam & roof Slab

Page 11: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

58 Centring & Shuttering :- Centring and

shuttering including strutting, propping etc.

at 1St floor level and removal of form for.

Suspended floors, roofs, landings,

balconies and access platform. sqm 213

Lintels beam,roof beams, and cantilevers.sqm 46

Columns, Pillars, Piers, Abutments, Posts

and Strutssqm 111

Stairs,(excluding landings) except spiral-

staircases.sqm 11

Chhaja ,Perdi, Vertical and horizontal fins

individually or forming box louvers band,

facias and eaves boards

sqm 12.5

59 Reinforcement for R.C.C. work including

straightening, cutting, bending, placing in

position and binding all complete.

Thermo-Mechanically Treated bars TMTC-

500-8mm dia.kg 1454

Thermo-Mechanically Treated bars TMTC-

500-10mm dia.kg 855

Thermo-Mechanically Treated bars TMTC-

500-12mm dia.kg 142

Thermo-Mechanically Treated bars TMT

Fe-500-I6mrn dia.kg 210

Mild steel 6.0 mm dia in Cannopy kg 47

Finishing work

Cement plaster in course sand

60 20mm Th Cement plaster with course

sand on outer wall at 1St Floor Level in

1:6 cement mortar(1 cement: 6 coarse

sand)

sqm 326

61 12mm Th Cement plaster with course

sand on inner wall , window sill & copla

from P.L to 1St Floor Level in 1:6 cement

mortar (1 cement: 6

coarse sand)

sqm 311

62 6mm Th Cement plaster in ceiling

1:4 cement mortar(1 cement : 4 coarse

sand)

sqm 246

Painting

63 Applying one coat of white cement primer

of approved brand and manufacture on

exterior wall surface:

sqm 325

64 Finishing walls with water proofing cement

paint(Snowcem) of approve brand and

manufacture and of required shade to give

an even shade new work (Three or more

coat).

sqm 325

Reinforcement in column,Lintel beam,Stair roof beam & roof slab

Page 12: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

65 Distempering with dry distemper of

approved brand and manufacture

(Ashian/Berger/) two or more coats and of

required shade on new work ,over and

including primimn coat of whiting to given

an even shade.

sqm 559

66 Applying priming coat with ready mixed

aluminum primer of approved brand and

manufacture on resinous wood and

plywood.

sqm 96

67 Painting with synthetic enamel paint of

approved brand and manufacture with

enamel putty in all shades to give an even

shade New wood work (two or more coats)

sqm 96

68 With ready mixed zinc chromate yellow

primer of approved brand and manufacture

on steel galvanized iron/steel workssqm 46

69 Painting with synthetic enamel paint of

approved brand and manufacture with

enamel putty in all shades to give an even

shade New steel work (two or more coats)

sqm 46

Flooring work

70 P.C.C Flooring:- 40mm Th cement

concrete flooring 1:2:4(1Cement:2

Coarse:4 Grade stone aggregate)finished

with a floating coat of neat cement

including cement slurry etc.

sqm 161

71 Skirting :- 18mm Th Cement plaster

skirting (up to 15 Cm height) with cement

mortar 1:3(1Cement : 3 coarse sand )

finished with a floating coat of neat cement

.

sqm 26.5

72 Providing and laying 20mm Th Granite

slab on cooking platform.Sqm 3.50

73 Ceramic Floot tile in Toilet :- Providing

and laying Ceramic glazed floor tiles

300x300 mm (thickness to be specified by

the manufacturer) of ist quality conforming

to IS : 15622 of approved make in colours

such as white , Ivory , Grey , Fume Red ,

Brown , laid on 20 mm thick Cement motar

1:4 (1 cement: 4 coarse sand ) including

pointing the joints with white cement and

matching pigment etc., complete.

sqm 21

Page 13: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

74 Ceramic wall tile for Dado :- Providing

and fixing 1st quality ceramic glazed wall

tiles in toilet up to 1.8M & above cooking

platform,shink & wash basin up to 0.61M

height ,conforming to IS : 15622

(Thickness to be specified by the

manufacture) of approved make in all

colours, shades except burgundy , bottle

green , black of any size as approved by

Engineer-in-charge in dados over 12 mm

thick bed of cement Motar 1:3(1 cement: 3

coarse sand ) and jointing with grey

cement slurry @ 3.3 kg per sqm including

pointing in white cement mixed with

pigment of matching shade complete.

sqm 61

Door & Window

75 Door chowkhat :-Providing and fixing

pressed steel door frame confirming IS

code 351 manufactured from commerical

mild steel sheet of 1.25 mm thickness

including hinges, jamb, lock jamb, bead

and if required angle threshold of mild

steel angle of section 50 x 25 mm or base

ties of 1.25mm pressed mild steel welded

or rigidly fixed together by . mechnical

means, adjustable lugs with split end tail to

each jamb including steel butt hinges 2.5

mm thick with mortar guards, lock strike-

plate and shock absorbers as specified

and applying a coat of approved steel

primer after pre-treatment of the surface as

directed by Engineer-in-charge:

Profile C

meter 33

76 Door Shutter:-Providing and fixing 35mm

Th flush door shutters non-decorative

type,core of block board construction with

frame of 1 st class hard wood and well

matched commercial 3 ply veneering with

vertical grains or cross bands and face

veneers on both faces of shutters.

including anodized aluminum butt hinges

with necessary screws.

sqm 48

77 Extra for providing lipping with 2nd class

teak wood battens 25 mm minimum depth

on all edges of shutters (overall area of

door shutter to be measured)

sqm 48

Page 14: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

78 Providing and fixing 85mmx42mm oxidised

M.S. pull bolt lock conforming to IS:7534

with necessary screws bolts nut and

washers etc. complete

each 16

79 providing 40x5 mm flat iron hold fast 40 cm

long including fixing to frame with 10 mm

diameter bots,nuts and wooden plugs and

embeddings in cement concrete block

30x10x15 cm 1:3:6 mix (1 cement :3

coarse sand :6 graded stone aggregate 20

mm nominal size)

each 184

80 Providing and fixing oxidised M.S.tower

bolt 150x10mm black finish in toilet,(barrel

type) with necessary screws etc.completeeach 12

81 Providing and fixing bright finished brass

hangging type floor door stoper with

necessary screws etc. compelte.each 15

82 Providing and fixing IS:3564 bright finished

brass hydraulic door closer (best make of

approved quality) with necessary

accessories and screws etc.in Domitory.

each 4

83 Providing and fixing 125 mm long

M.S.handles with necessary screws

etc.complete

Each 72

84 Window grill :- Providing and fixing M.S.

grills of requirement pattern in frames of

windows etc. with M.S. flats bars 5mm Th

& 20mm wide or 10mm x 10mm square

bars @ 100mm C/C Vertical /horizontal

etc.all complete, fixed to openings/wooden

frames with rawl plugs screws etc.

kg 68

85 Steel glazed window :- Providing and

fixing steel glazed windows and ventilatrs

of standard rolled steel sections, joints

mitered and welded with 15x3 mm lugs 10

cm long with steel lugs embedded in

cement concrete blocks 15x10x10 cm of

1:3:6(1 cement: 3 coarse sand : 6 graded

stone aggregate 20 mm nominal size) or

with woodenplugs and screws or rawl

plugs and screws or with fixing clips or

with bolts and nuts as required, including

providing and fixing of glass panes with

glazing clips and special metal-sash putty

of approved make complete including

applying a priming coat of approved steel

primer; excluding the cost of metal beading

and other fitting except necessary hinges

or pivots as required.

Sqm 45

Page 15: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

86 Providing and fixing M.S.fan clamp type 1

of 16 mm dia.M.S. bar bent to shape with

hooked ends in R.C.C slabs during laying

including painting the exposed portion of

loop,all as per standard design complete.

each 23

87 Providing and fixing circular cast iron box

for ceiling fan clamp 140 mm internal dia,

73 mm height, 5 mm thick rim bottom and

top lids, 1.5 mm thick M.S sheet with its

top surface hacked for proper bonding top

lid shall be screwed into the cast iron box

by means of 3.3 mm dia round headed

screws, one ;pcf at the corners. Clamps

shall be made of 12 mm dia M.S. bar bent

to shape as per standard drawing.

each 23

88 Water Proofing :- Providing and laying

water proofing treatment to vertical and

horizontal surfaces of depressed portions

of W.C. kitchen and the like consisting of:

(i) 1st course of applying cement slurry @

4.4 kg/sqm mixed with water proofing

compound conforming tc IS 2645 in

recommended proportions.

(ii) 11 nd course of 20 mm cement plaster

1:3 (1 cement:3 coarse sand)mixed

with water proofing compound in

recommended proportion, (iii)

Illrd course of applying blown or/residual

bitumen aplied hot at 1.7 kg. per sqm of

area, (iv) Ivth course of 400 micron

thick PVC sheet.(Overlaps at joints of PVC

shet should be 100 mm wide and pasted to

each other with bitumen @ 1.7 kg/sqni).

sqm 30

89 Steel work welded in built up

sections/framed work including cutting

hoisting, rixing in position and applying a

priming coat of approved steel primer

using structural steel, etc. as required. M.S

Baluster 10mmx10mmx900mm each steps

,mild steel flats bar 25mmx5mm over

baluster.

kg 35

90 Providing and fixing hand rail G.I Pipes 40

mm normal bore by welding etc. to steel

ladder railings & staircases railing

including applying a priming coat of

approved steel primer . In

stringers, treads landings etc. of stair

cases.

kg 90

Total Section lll:-

Page 16: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

Brick work

91 250mm Th Brick work with bricks of class

designation 100A at 1St Floor Level in :

Cement mortar 1:6 (1 cement: 6 coarse

sand )cum 56

92 125mm Th Half brick masonry with bricks

of class designation 100A above plinth

up to 1St floor Level in :

Cement mortar 1:4 (1 cement: 4 coarse

send)sqm 26

93 Extra for providing and placing in position

2 Nos, 6 mm dia , MS bars at every third

course of half brick masonry.sqm 26

94 Providing and laying in position machine

batched, machine mixed and machine

vibrated design mix cement concrete of

specified grade for reinforced cement

concrete structural elements, excluding the

cost of centring, shuttering finishing and

reinforcement, M-20 grade reinforced

cement concrete.

1:1:5:3(1 cement: 1.5 coarse sand:3

graded stone aggregate 20 mm nominal

size)

All work above plinth level(Walls columns,

pillars, posts cind struts)cum 6.5

Beams, planth beams, girders,

bressumers, contilevers,Suspended floors

lintels roofs and staircases including spiral

staircases, shelves etc

cum 56

95 Centring & Shuttering :- Centring and

shuttering including strutting, propping etc.

at 1St floor level and removal of form for.

Suspended floors, roofs, landings,

balconies and access platform.sqm 205

Lintels beam,roof beams, and cantilevers.sqm 102

Columns, Pillars, Piers, Abutments, Posts

and Strutssqm 96

Stairs,(excluding landings) except spiral-

staircases.sqm 12

SECTION IV -AT SECOND FLOOR

R.C.C work in Column ,Lintel beam & Chhaja ,Roof beam & roof Slab

Page 17: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

Chhaja ,Perdi, Vertical and horizontal fins

individually or forming box louvers band,

facias and eaves boards

sqm 12

96 Reinforcement for R.C.C. work including

straightening, cutting, bending, placing in

position and binding all complete.

Thermo-Mechanically Treated bars TMTC-

500-8mm dia.kg 1426

Thermo-Mechanically Treated bars TMTC-

500-10mm dia.kg 855

Thermo-Mechanically Treated bars TMTC-

500-12mm dia.kg 17

Thermo-Mechanically Treated bars TMT

Fe-500-I6mrn dia.kg 98

Mild steel 6.0 mm dia in cannopy kg 47

Finishing work

Cement plaster in course sand

97 20mm Th Cement plaster with course

sand on outer wall at 1St Floor Level in

1:6 cement mortar(1 cement: 6 coarse

sand)

sqm 173

98 12mm Th Cement plaster with course

sand on inner wall , window sill & copla

from P.L to 1St Floor Level in 1:6 cement

mortar (1 cement: 6

coarse sand)

sqm 235

99 6mm Th Cement plaster in ceiling

1:4 cement mortar(1 cement : 4 coarse

sand)

sqm 132

Painting

100 Applying one coat of white cement primer

of approved brand and manufacture on

exterior wall surface:

sqm 175

101 Finishing walls with water proofing cement

paint(Snowcem) of approve brand and

manufacture and of required shade to give

an even shade new work (Three or more

coat).

sqm 175

102 Distempering with dry distemper of

approved brand and manufacture

(Ashian/Berger/) two or more coats and of

required shade on new work ,over and

including primimn coat of whiting to given

an even shade.

sqm 367

103 Applying priming coat with ready mixed

aluminum primer of approved brand and

manufacture on resinous wood and

plywood.

sqm 31

Reinforcement in column,Lintel beam,Stair roof beam & roof slab

Page 18: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

104 Painting with synthetic enamel paint of

approved brand and manufacture with

enamel putty in all shades to give an even

shade New wood work (two or more coats)

sqm 31

105 With ready mixed zinc chromate yellow

primer of approved brand and manufacture

on steel galvanized iron/steel workssqm 28

106 Painting with synthetic enamel paint of

approved brand and manufacture with

enamel putty in all shades to give an even

shade New steel work (two or more coats)

sqm 28

Flooring work

107 P.C.C Flooring:- 40mm Th cement

concrete flooring 1:2:4(1Cement:2

Coarse:4 Grade stone aggregate)finished

with a floating coat of neat cement

including cement slurry etc.

sqm 50

108 Skirting :- 18mm Th Cement plaster

skirting (up to 15 Cm height) with cement

mortar 1:3(1Cement : 3 coarse sand )

finished with a floating coat of neat cement

.

sqm 21.0

109 Providing and laying 20mm Th Granite

slab on cooking platform.Sqm 8.0

110 Ceramic Floot tile in Toilet :- Providing

and laying Ceramic glazed floor tiles

300x300 mm (thickness to be specified by

the manufacturer) of ist quality conforming

to IS : 15622 of approved make in colours

such as white , Ivory , Grey , Fume Red ,

Brown , laid on 20 mm thick Cement motar

1:4 (1 cement: 4 coarse sand ) including

pointing the joints with white cement and

matching pigment etc., complete.

sqm 6.5

Page 19: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

111 Ceramic wall tile for Dado :- Providing

and fixing 1st quality ceramic glazed wall

tiles in toilet up to 1.8M & above cooking

platform,shink & wash basin up to 0.61M

height ,conforming to IS : 15622

(Thickness to be specified by the

manufacture) of approved make in all

colours, shades except burgundy , bottle

green , black of any size as approved by

Engineer-in-charge in dados over 12 mm

thick bed of cement Motar 1:3(1 cement: 3

coarse sand ) and jointing with grey

cement slurry @ 3.3 kg per sqm including

pointing in white cement mixed with

pigment of matching shade complete.

sqm 27

Door & Window

112 Door chowkhat :-Providing and fixing

pressed steel door frame confirming IS

code 351 manufactured from commerical

mild steel sheet of 1.25 mm thickness

including hinges, jamb, lock jamb, bead

and if required angle threshold of mild

steel angle of section 50 x 25 mm or base

ties of 1.25mm pressed mild steel welded

or rigidly fixed together by . mechnical

means, adjustable lugs with split end tail to

each jamb including steel butt hinges 2.5

mm thick with mortar guards, lock strike-

plate and shock absorbers as specified

and applying a coat of approved steel

primer after pre-treatment of the surface as

directed by Engineer-in-charge:

Profile C

meter 10.5

113 Door Shutter:-Providing and fixing 35mm

Th flush door shutters non-decorative

type,core of block board construction with

frame of 1 st class hard wood and well

matched commercial 3 ply veneering with

vertical grains or cross bands and face

veneers on both faces of shutters.

including anodized aluminum butt hinges

with necessary screws.

sqm 16

114 Extra for providing lipping with 2nd class

teak wood battens 25 mm minimum depth

on all edges of shutters (overall area of

door shutter to be measured)

sqm 16

Page 20: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

115 Providing and fixing 85mmx42mm oxidised

M.S. pull bolt lock conforming to IS:7534

with necessary screws bolts nut and

washers etc. complete

each 2

116 providing 40x5 mm flat iron hold fast 40 cm

long including fixing to frame with 10 mm

diameter bots,nuts and wooden plugs and

embeddings in cement concrete block

30x10x15 cm 1:3:6 mix (1 cement :3

coarse sand :6 graded stone aggregate 20

mm nominal size)

each 8

117 Providing and fixing oxidised M.S.tower

bolt 150x10mm black finish in toilet,(barrel

type) with necessary screws etc.completeeach 2

118 Providing and fixing bright finished brass

hangging type floor door stoper with

necessary screws etc. compelte.

each 8

119 Providing and fixing 125 mm long

M.S.handles with necessary screws

etc.complete

Each 8

120 Window grill :- Providing and fixing M.S.

grills of requirement pattern in frames of

windows etc. with M.S. flats bars 5mm Th

& 20mm wide or 10mm x 10mm square

bars @ 100mm C/C Vertical /horizontal

etc.all complete, fixed to openings/wooden

frames with rawl plugs screws etc.

kg 42

121 Steel glazed window :- Providing and

fixing steel glazed windows and ventilatrs

of standard rolled steel sections, joints

mitered and welded with 15x3 mm lugs 10

cm long with steel lugs embedded in

cement concrete blocks 15x10x10 cm of

1:3:6(1 cement: 3 coarse sand : 6 graded

stone aggregate 20 mm nominal size) or

with woodenplugs and screws or rawl

plugs and screws or with fixing clips or

with bolts and nuts as required, including

providing and fixing of glass panes with

glazing clips and special metal-sash putty

of approved make complete including

applying a priming coat of approved steel

primer; excluding the cost of metal beading

and other fitting except necessary hinges

or pivots as required.

Sqm 28

Page 21: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

122 Providing and fixing M.S.fan clamp type 1

of 16 mm dia.M.S. bar bent to shape with

hooked ends in R.C.C slabs during laying

including painting the exposed portion of

loop,all as per standard design complete.

each 6

123 Providing and fixing circular cast iron box

for ceiling fan clamp 140 mm internal dia,

73 mm height, 5 mm thick rim bottom and

top lids, 1.5 mm thick M.S sheet with its

top surface hacked for proper bonding top

lid shall be screwed into the cast iron box

by means of 3.3 mm dia round headed

screws, one ;pcf at the corners. Clamps

shall be made of 12 mm dia M.S. bar bent

to shape as per standard drawing.

each 6

124 Water Proofing :- Providing and laying

water proofing treatment to vertical and

horizontal surfaces of depressed portions

of W.C. kitchen and the like consisting of:

(i) 1st course of applying cement slurry @

4.4 kg/sqm mixed with water proofing

compound conforming tc IS 2645 in

recommended proportions.

(ii) 11 nd course of 20 mm cement plaster

1:3 (1 cement:3 coarse sand)mixed

with water proofing compound in

recommended proportion, (iii)

Illrd course of applying blown or/residual

bitumen aplied hot at 1.7 kg. per sqm of

area, (iv) Ivth course of 400 micron

thick PVC sheet.(Overlaps at joints of PVC

shet should be 100 mm wide and pasted to

each other with bitumen @ 1.7 kg/sqni).

sqm 7.5

125 Steel work welded in built up

sections/framed work including cutting

hoisting, rixing in position and applying a

priming coat of approved steel primer

using structural steel, etc. as required. M.S

Baluster 10mmx10mmx900mm each steps

,mild steel flats bar 25mmx5mm over

baluster.

kg 35

126 Providing and fixing hand rail G.I Pipes 40

mm normal bore by welding etc. to steel

ladder railings & staircases railing

including applying a priming coat of

approved steel primer . In

stringers, treads landings etc. of stair

cases.

kg 90

Page 22: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

Brick work

127 250mm Th Brick work with bricks of class

designation 100A at 1St Floor Level in :

Cement mortar 1:6 (1 cement: 6 coarse

sand )cum 27

128 Providing and laying in position machine

batched, machine mixed and machine

vibrated design mix cement concrete of

specified grade for reinforced cement

concrete structural elements, excluding the

cost of centring, shuttering finishing and

reinforcement, M-20 grade reinforced

cement concrete.

1:1:5:3(1 cement: 1.5 coarse sand:3

graded stone aggregate 20 mm nominal

size)

All work above plinth level(Walls columns,

pillars, posts cind struts)cum 1.5

Beams, planth beams, girders,

bressumers, contilevers,Suspended floors

lintels roofs and staircases including spiral

staircases, shelves etc

cum 55

129 Centring & Shuttering :- Centring and

shuttering including strutting, propping etc.

at 2nd floor level and removal of form for.

Suspended floors, roofs, landings,

balconies and access platform.sqm 205

Lintels beam,roof beams, and cantilevers.sqm 102

Columns, Pillars, Piers, Abutments, Posts

and Strutssqm 95

130 Reinforcement for R.C.C. work including

straightening, cutting, bending, placing in

position and binding all complete.

Thermo-Mechanically Treated bars TMTC-

500-8mm dia.kg 1426

Thermo-Mechanically Treated bars TMTC-

500-10mm dia.kg 855

Thermo-Mechanically Treated bars TMTC-

500-12mm dia.kg 70

Thermo-Mechanically Treated bars TMT

Fe-500-I6mrn dia.kg 98

Finishing work

Cement plaster in course sand

Total Section lV:-

Section V ( Mumty B/U Area 35Sqm & Parapet wall)

R.C.C work in Column Roof beam & mumty Slab

Reinforcement in column,roof beam & mumty slab

Page 23: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

131 20mm Th Cement plaster with course

sand on outer wall at 1St Floor Level in1:6

cement mortar(1 cement: 6 coarse sand)sqm 59

132 12mm Th Cement plaster with course

sand on inner wall , window sill & copla

from P.L to 1St Floor Level in 1:6 cement

mortar (1 cement: 6

coarse sand)

sqm 57

133 6mm Th Cement plaster in ceiling

1:4 cement mortar(1 cement : 4 coarse

sand)

sqm 131

Painting

134 Applying one coat of white cement primer

of approved brand and manufacture on

exterior wall surface:

sqm 62

135 Finishing walls with water proofing cement

paint(Snowcem) of approve brand and

manufacture and of required shade to give

an even shade new work (Three or more

coat).

sqm 65

136 Distempering with dry distemper of

approved brand and manufacture

(Ashian/Berger/) two or more coats and of

required shade on new work ,over and

including primimn coat of whiting to given

an even shade.

sqm 137

137 With ready mixed zinc chromate yellow

primer of approved brand and manufacture

on steel galvanized iron/steel workssqm 9.5

138 Painting with synthetic enamel paint of

approved brand and manufacture with

enamel putty in all shades to give an even

shade New steel work (two or more coats)

sqm 10

Door & Window

Page 24: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

139 Door chowkhat :-Providing and fixing

pressed steel door frame confirming IS

code 351 manufactured from commerical

mild steel sheet of 1.25 mm thickness

including hinges, jamb, lock jamb, bead

and if required angle threshold of mild

steel angle of section 50 x 25 mm or base

ties of 1.25mm pressed mild steel welded

or rigidly fixed together by . mechnical

means, adjustable lugs with split end tail to

each jamb including steel butt hinges 2.5

mm thick with mortar guards, lock strike-

plate and shock absorbers as specified

and applying a coat of approved steel

primer after pre-treatment of the surface as

directed by Engineer-in-charge:

Profile C

meter 11

140 Door Shutter:-Providing and fixing 35mm

Th flush door shutters non-decorative

type,core of block board construction with

frame of 1 st class hard wood and well

matched commercial 3 ply veneering with

vertical grains or cross bands and face

veneers on both faces of shutters.including

anodized aluminum butt hinges with

necessary screws.

sqm 4.6

141 Extra for providing lipping with 2nd class

teak wood battens 25 mm minimum depth

on all edges of shutters (overall area of

door shutter to be measured)

sqm 5

142 Providing and fixing 85mmx42mm oxidised

M.S. pull bolt lock conforming to IS:7534

with necessary screws bolts nut and

washers etc. complete

each 4

143 providing 40x5 mm flat iron hold fast 40 cm

long including fixing to frame with 10 mm

diameter bots,nuts and wooden plugs and

embeddings in cement concrete block

30x10x15 cm 1:3:6 mix (1 cement :3

coarse sand :6 graded stone aggregate 20

mm nominal size)

each 12

144 Providing and fixing oxidised M.S.tower

bolt 150x10mm black finish ,(barrel type)

with necessary screws etc.completeeach 2

145 Providing and fixing 125 mm long

M.S.handles with necessary screws

etc.complete

Each 2

Page 25: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

146 Window grill :- Providing and fixing M.S.

grills of requirement pattern in frames of

windows etc. with M.S. flats bars 5mm Th

& 20mm wide or 10mm x 10mm square

bars @ 100mm C/C Vertical /horizontal

etc.all complete, fixed to openings/wooden

frames with rawl plugs screws etc.

kg 16

147 Steel glazed window :- Providing and

fixing steel glazed windows and ventilatrs

of standard rolled steel sections, joints

mitered and welded with 15x3 mm lugs 10

cm long with steel lugs embedded in

cement concrete blocks 15x10x10 cm of

1:3:6(1 cement: 3 coarse sand : 6 graded

stone aggregate 20 mm nominal size) or

with woodenplugs and screws or rawl

plugs and screws or with fixing clips or

with bolts and nuts as required, including

providing and fixing of glass panes with

glazing clips and special metal-sash putty

of approved make complete including

applying a priming coat of approved steel

primer; excluding the cost of metal beading

and other fitting except necessary hinges

or pivots as required.

Sqm 10.0225

Page 26: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

148 Providing and laying APP (Atactic

Polypropylene Polymer) modified

prefabricated five layer, 3 mm thick water

proofing membrane, black finished

reinforced with glass fibre matt consisting

of a coat of bitumen primer for bitumen

membrane @0.40 litre/ sqm by the same

membrane manufactured of density at 25°

C, 0.87 - 0.89 kg/ litre and viscocity 70 -

160 cps. Over the primer coat the layer of

membrane shall be laid using butane torch

and sealing all joints etc., and

preparing the surface complete. The vital

physical and chemical parameters of the

membrane shall be as under : Joint

strength in longitudinal and transverse

direction at 23°C as 350/300 N/5 cm. Tear

strength in longitudinal and transverse

direction as 60/80N. Softening point of

membrane not less than 150°C. Cold

flexibility shall be upto -

2°C when tested in accordance with

ASTM, D - 5147. The laying of membrane

shall be got done through the authorised

applicator of the

manufacturer of membrane.

sqm 310

Total Section V:-

Grand total Sub head A-

Page 27: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

Section l (Electric wiring)

SL No DESCRIPTION OF WORK UNIT QUANTITY RATE AMOUNT

1

Point wiring in pvc conduit with modular

type switch wiring for lightpt/ fan pt / call

bell pt with 1.5 S Q.m.m.F.R pvc insulated

copper conductor single core cable in

surface/ recessed pvc conduit with

modular type switch , modular plate

suitable size GI boox etc as required.

a Group C each 153

b Group A each 35

2

Twin control wiring in pvc conuit with

modular type switch : wiring in pvc conduit

with modular type switch: wiring for twin

control light point with 1.5 S Qmm F.R pvc

insulated copper conductor single core

cable in surface / recessed pvc conduit, 2

way modular type switch, modular plate

suilable size GI Box etc as required

point 3.00

3

Power plug wiring in pvc conduit

(2x4Sqmm) – wiring for light / power plug

with 2x4 SQ.mm.F.R pvc insulated copper

conductor single core cable in surface/

recessed pvc conduit, along with 1No

4&Q.mm.F.R pvc insulated copper

conductor single core cable for loop

earthing as required

Mtr 110.00

4

Circuit/ sub main wiring in pvc conduit:

wiring for circuit /sub main wiring along

with earth wire with following size of pvc

insulated copper conductor single core

surface/recessed pvc conduit as required

a 2x1.5+1x2.5 Mtr 192

b 2x2.5+1x2.5 Mtr 314

c 4x6+2x6 Mtr 35

d 4x10+2x10 Mtr 24

5

Telephone wiring in existing conduit:

supplying and drawing following pair 0.5

SQmm.F.RLS pvc insulated copper

conductor unarmoured telephone cable in

the existing surface/ recessed pvc conduit

as required

SUB HEAD B (ELECTRICAL WORK) GROUND,1St & 2nd FLOOR

Page 28: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

a 2 pair Meter 232

6

S/F pvc conduit supply and fixing following

sizes pvc conduit along with accessories in

surface /recess including cutting the wall

and making good the same in case

recessed conduit as required

a 25mm Mtr 26

7

S/F modular type switch/socket:- supplying

and fixing following modular type

switch/socket on the existing modular plate

and switch box in duding connection but

excluding modular plate etc.

a 5 amp one way switch each 45

b 5 /6 amp 3 pin socket out let each 45

c 15/16 amp 6 pin socket out let each 7

d 15/16 amp one way swich each 7

e telephone socket outlat each 8

8

S/F modular box base and cover plate

supplying and fixing modular GI boxes

along with modular base and cover plate

for modular switch & socket etc as

required .

a 1 or 2 module (75x75x45)mm each 18

b 4/5 module (78x140x50)mm each 19

9

S/F suitable size GI box with modular plate

cover in front on surface or in recess

including providing and fixing 6 pin, 15/16

amp modular socket outlet and 15/16 amp

switch connection painting etc.

each 3

10S/F ceiling rose supply and fixing 2 pin

same ceiling rose on existing jn box each 106

11Batten holder :-supplying & fixing

batten/angular holder including connection

etc as required.

each 4

12

S/Fdingdong call bell:-supply and fixing

dingdong call bell suitable for DC/AC

single phase 230 volte complete as

required

each 1

13

S/F twin twisted cable in conduct :-Twin

twisted cable in conduit P/F plain 16/0.20

mm (0.50 SQmm) twin twisted FR pvc

insulated copper cable in polythene sleeve

of suitable size on floor/wall.

each 106

Page 29: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

14

ITC Fluorescent fitting directly on

surface:- Installation testing and

commissioning of per – wired ,fluoresent

fitting of alln type ,complete with all fitting

of all type complete with all accessories

and tube etc directly on ceiling/wall

including connection with 1.5 SQ mm FR

pvc insulated copper conductor ,single

core cable and earthing etc. as required

each 93

15

S/F 20 amp, 240v SPN industrial type

socket out let with 2 pole and earth, metal

enclosed plug top along with 20A C' serier

P MCB in sheet steel encloser on

surfagrears with chained metal sover

farthe socket complte with connection etc

or as requived.

each 3

16

I.T.C ceiling fan:- installation testing and

commissioning of ceiling fan including

wiring the down road of standard length

(up to 30 cm) with 1.5 SQ.mm FR pvc

insulated copper conductor, single core

cable as required.

each 44

17

S/f modular electronic fan regulator:-

S/F stepped type electronic fan regulator

the existing modular plate switch box

including connection but excluding

modular plate etc.

each 44

18

I.T.C Exhaust fan up to 450mm sweep:-

Installation of exhaust fanup to 450 mm.

sweep in the existing opening including

making the hole to suit the size of the

above fan making good the dimage

connection testing commissioning etc as

required

each 14

19

Fixing louvers shutter for exhaust fan extra

for fixing the louvers shutters complete

with frame for a exhaust fan of all size.

each 14

20

Supply and fixing TPMCB supply and

fixing following way three pole and neutral

sheet MCB distribution board 415v on

surface/recess complete with tinned

copper bus- bar neutral bus- bar earth bar

din bar detachable glane plate inter

connections phos phatized and power

pointed including earthing etc as required

(But without MCB/RCCB/isolator )

a 6way (4+18)double door horizontal type each 6

Page 30: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

21

S/F `C` series MCB :- supply and fixing

following 240 volts `C` series MCB suitable

for inductive loads of following poles in the

existing MCB DB complete with connection

testing and commissioning etc as required.

a 6/32 amps S.P each 30

22

S/F four pole MCB Isolator:- supply and

fixing following rating four pole 415volt

isolator in existing MCB DB complete with

connection testing and commissioning etc

as required

a 63 amps each 2

b 40 amps each 4

23

S/F TPN RCCB:- supplying and fixing

following rating TPN 415V RCCB, having a

sensitivity current up to 300 ma in the

existing MCB-DB complete with

connection testing and commissioning etc

as required.a 63 amps each 1

b 100 amp each 1

24Supply and fixing blanking plate (sing pe

pote in existair Db)each 32

25

S/F bus bar chamber:- providing and

fixing following rating bus bar chamber

with 4 strip of suitable size made of copper

heavy duty complete with all accessories

including connection earthing the body etc

as required

a 200 amps each 1

26

S/f MCCB in cubical panel board :-

providing and fixing following rating and

capacity four pole MCCB in existing

capacity cubical panel board including

holes in cubical panel making connection

etc as required a 200 amps 35ka fixed thermal setting each 1

27

Copper earth plate electrode:- Ear thing

with copper plate 600mmx600mmx3mm

thick including accessories and providing

masonry in closer with plate having locking

arrangement and watering pipe etc as

required with char coal and salt and salt

as required

set 2

28

S/L 8SWG Copper wire in ground:-

supplying and laying 8 SWG copper wire

at 0.5 meter below Gr level for conductor

earth electrode including soldering etc as

required

Mtr 66

Total Section I -

Page 31: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

Section ll (Lighting conductor)

29

Earth plate Electrode:- Earth with GI

earth plate 600mmx600mmx6mm thick

including accessories encloser with cover

plate having locking arrangements and

watering pipe etc as required ( but with out

– char coal or coke and salt)

set 2

30

Salt/coke for plate earth electrode:-

Extra for using saltandRE charcoal far GI

or copper plate earth electrode as required

set 2

31

P/F copper lightning conductor finial, made

of 25mm dia 300mm long GI tube having

single prong at top with 85mm 3mm thick

GI base plate including holes etc complete

as required

each 2

32

Reverting, sweating and soldering

conductor:- reverting & lightring and

soldering of GI tape (with another copper)

GI tape, base of the final or any other

metallic object as required.

each 28

33

P/F GI lightring conductor tape in

horizontal run:- Providing and fixing GI

tape 20mm x 3mm tick on parapet or

surface of wall for lightring conductor

complete as required

Mtr 123

34

P/F GI lightring conductor tape in

vertical run:- Providing and fixing GI tape

20mm x 3mm tick on parapet or surface of

wall for lightring conductor complete as

required

Mtr 15

35

P/F testing joint for GI lightring

conductor:- providing and fixing testing

joints made of 20mm x 3mm thick GI strip

125mm long with 4 nos GI bolts nuts check

nuts and spring washersetc. Complete as

required

each 56

36

P/F GI earth tape for lightring

conductor:- providing and laying GI tape

32mm x 6mm earth electrode directly

ingras Required.

Mtr 16

37

MV cable laying up to 120 Sqmm in Gr :-

Laying of one no PVC insulated and PVC

sheathed/ XLPE power cable of 1.1KV

grade of size not exceeding 120 Sqmm

ground including excavation protective

covering and re Filling the trench etc as

required

Mtr 90

38

P/F danger notice plate providing and

fixing MV danger notice plate 200mmv

150mm made of mild steel at least 2 mm

thick and vitreous White on both side with

inscription in single red color on front side

each 1

Page 32: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

39

S/F panel mounted change over

switches:- Providing and fixing following

capacity 4 pole panel mounted change

over switches in existing cubical panel

board making connection earthing the

body etc as required

a 200A 4 pole each 1

b Supply of 3.5 x 50 Sqmm x LPE/PVCA (Al) cable 1.1KV gradeMtr 90

40

Supply,installation, testing &

commissioning of the following light

fixtures complete with lamps, electronic

ballasts, lamp holder, starter, starter

holder, etc. duly wired complete for use on

240 V single phase 50 Hz AC supply

including all accessories required for

mounting at surface/recess/wall as

mentioned in BOQ and drawings

conforming to relavant IP protection and

IS codes.

a

Supply & Fixing 1 x 28 W fluorescent tube

light fitting Make Havells Lamp Type -

1x28W FTL T5 ,Odering code -

LHIT81128032

66

b

Supply & fixing 1x14W Fluorescent wall

mounted mirror luminaire (Philips Cat NO

-ADRENO V2 14WTWG 207 1xTL5-14W 2

c

1 x 9 W CFL wall bracket fitting make

Phillips/Bajaj/Crompton/equivalent+ isi

market

15

41

Supply and fixing surface down light make

havells , Lamp type -2x18W PL-C/DU-CFL

Ordering code -LHOC1521845419

42

Providing and fixing with 18/20w CFL

(essential) in existing angular/ battu Holder

make Phillips/Bajaj/Crompton

each 5

43

Supply of 56" (1440mm)sweep double ball

bearing ceiling fan with down rod, shackle

insulator canopy complete but without

regulator 230V AC make Crompton/

havells or equivallant i.s.i market

each 48

44

Supply of 12” (300mm)sweep exhaust fan

heavy duty double ball bearing 230V AC

make Crompton/ havells or equivallant i.s.i

market

each 14

45

Supply and fixing cubical type panel box to

accommodate 200A 4 pole change over

switch complete with all accessories and

gland box for cables termination (incomer

and out going cables)

Each 1

46 S/F roary Switch 63A Each 1

Page 33: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

47

End termination of Armod cable 50Sqmm

Each 2

Section lll -EXTERNAL ELECTRIFICATION

48 Supply ,fabrication and delivery of tubular

poles for street light 9 M long (SP-31) with

base plate for street light (IS-1161-SP -31) Each 6

49 Supply of skyline SGP-325 Street light

luminaire with press wire die-cast

Aluminum housing POT -optics reflector

and heat resistant toughened flat glass

cover (IP-65)SGP 325-1x1+PITP-150W

FG.

Each 6

50 Supply of 4x10Sqmm x LPE PVC

Aluminum armoured cabel 1.1 KV grade. 200

51 Supply of 63Amp TPN Switch with HRC

Fuses.Each 1

Section lll:-

Total sub head B -

Total Section II -

Page 34: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

Sl No Description Item Ground floor estimate Unit Quantity Rate Amount

(I) Sub-Head-l

WATER SUPPLY

G.I. PIPES AND FITTINGS

1

Providing and fixing G.I. pipes

complete with G.I. fittings and clamps,

including cutting and making good the wall

etc.

(A) 20 mm dia. Nominal bore Metre 62.00

(B) 25 mm dia. Nominal bore Metre 40.00

(C) 32 mm dia. Nominal bore Metre 6.00

(D) 40 mm dia. Nominal bore Metre 40.00

2

Concealed pipe including with anti

corrosive bitumatic paint, cutting chases

and making good the wall.

(A) 15 mm dia. Nominal bore Metre 85.00

(B) 20 mm dia. Nominal bore Metre 65.00

3

Providing and fixing G.I. pipes

complete with G.I. fittings including

trenching and refilling etc.

(B) 40 mm dia. Nominal bore Metre 25.00

SUB HEAD C (P.H.E WORK) GROUND,1st & 2nd FLOOR Ground ,1St Floor,2nd Floor

Page 35: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

4

Making connecting of G.I. distribution

branch with G.I. Main of following sizes

by providing and fixing tee, including

cutting and threading the pipe etc.

complete.

(A) 25 to 40 mm Nominal bore each 3.00

5Providing and fixing brass stop cock of

approved quality

(A) 20 mm Nominal bore each 9.00

6Providing and fixing brass gate valve with

C.I. wheel of approved quality.

(A) 32 mm Nominal bore Each. 1.00

(B) 40mm Nominal bore Each. 1.00

7Providing and fixing metal non-return

valve of approved quality.

32 mm nominal bore

Horizontal Each. 1.00

Vertical Each. 1.00

40 mm nominal bore

Horizontal Each. 1.00

Vertical Each. 1.00

8

Painting G.I. pipe and fittings with synthetic

enamel white paint over a ready mixed

priming coat, both of approved quality for

new work.

(A) 20 mm dia. Nominal bore Metre 12.00

(B) 25 mm dia. Nominal bore Metre 40.00

(C) 32 mm dia. Nominal bore Metre 6.00

(D) 40 mm dia. Nominal bore Metre 40.00

9

Providing and fixing G.I. union in G.I.pipe

including cutting and threading the pipe

and making long screws etc.

(A) 20 mm dia. Nominal bore each 4.00

(B) 25mm dia. Nominal bore each 7.00

(D) 40 mm dia. Nominal bore each 10.00

10

Providing and placing on terrace (at all

floor levels ) polythethylene water storage

tank of approved brand and manufacture

with cover and suitable locking

arrangement and making necessary holes

for inlet, outlet and overflow pipes but

without fittings and the base support for

tank 1000X7=7000 litre 7000.00

C.P. BRASS FITTINGS

11

Providing and fixing C.P brass bib cock of

approved quality confirming to IS:8931

15mm nominal bore Each 26.00

Page 36: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

12

Providing and fixing C.P brass long nose

bib cock of approved quality confirming to

IS standard and weighing not less

than810grams.15mm nominal bore Each 2.00

13

Providing and fixing C.P brass stop cock

(concealed) of standard design and of

approved make confirming to IS:8931

15mm nominal bore Each 14.00

14Providing and fixing CP brass shower rose

15 or 20 mm inlet150 mm diameter

Each 6.00

(II) Sub-Head-ll

Sanitary Installation

15

Providing and fixing water closet

squatting pan (Indian type W.C. pan )

with 100mm sand cast Iron P or S trap,

10 litre low level white P.V.C. flushing

cistern with manually controlled device

(handle lever) conforming to IS : 7231,

with all fittings and fixtures complete

including cutting and making good the

walls and floors wherever required :

(a)

White vitreous china orissa pattern W.C.

pan of size 580 x 440mm with integral

type foot rests.

Each 6.00

16

Providing and fixing white vitreous china

pedestal type water closet (European

type) with seat and lid, 10 litre low level

white vitreous china flushing cistern &

C.P. flush bend with fittings &

C.I.brackets, 40mm flush bend, overflow

arrangement with specials of standard

make and mosquito proof coupling of

approved municipal design complete

including painting of fittings and

brackets, cutting and making good the

walls and floors wherever required :

Total sub head -l

Page 37: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

(a)W.C. Pan with ISI marked white solid

plastic seat and lid.Each 6.00

17

Provding and fixing white vitreous china

wash basin with C.I./ MS brackets, 15 mm

C.P. brass pillar taps, , 32 mm C.P. brass

waste of standard pattern, including

paintings of fittings and brackets, cutting

and making good the .wall wherever

required.

flat back wash basin size 630X450mm

with single15mm CP pillar tapEach 13.00

18

Providing and fixing PTMT Bottle Trap for

Wash basin and sink. Bottle trap 31mm

single piece moulded with height of

270mm, effective length of tail pipe 260mm

from the centre of the waste coupling

77mm breadth with 25mm minimum water

seal, weighing not less than 260gms.

Each 13.00

19

Provding and fixing 600X450mm

bevelled edge mirror of superior glass

complete with 6mm thick hard board

ground fixed to wooden cleats with CP

brass screws & washers complete.

Each 12.00

20

Provding and fixing 600X120X5 mm glass

shelf with edges rounded off supported on

anodised aluminium angle frame with CP

brass brackets and guard rail complete

fixed with 40 mm long screws ,rawl plug

etc, complete.

Each 12.00

21

Provding and fixing towel rail complete

with brackets fixed to wooden cleats with

CP brass screws

600 X 20 mm size Each 7.00

22

Provding and fixing kitchen sink with C.I.

brackets, C.P. brass chain with rubber

plug,40mm CP brass waste complete ,

including paintings of fittings and brackets,

cutting and making good the .wall

wherever required.

white glazed fire clay sink of size

600x450x250mmEach 3.00

23

Provding and fixing PVC waste pipe for

sink & wash basin including PVC waste

fittings complete

40 mm dia Each 15.00

24.0Providing and fixing soil waste and vent

pipes

(a)

100mm diameter Centrifugally cast

(spun) iron socketed pipe as per IS:

3989.

Metre 135

Page 38: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

(b)75mm diameter Centrifugally cast (spun)

iron socketed pipe as per IS: 3989.Metre 30

25.0

Providing and fixing M.S. holder-bat

clamps of approved design to sand cast

iron centrifugally cast (spun) iron S&S

pipes embedded in and including cement

concrete blocks 10x 10 x 10 cm of 1:2:4

mix (1 cement : 2 coarse sand : 4 graded

stone aggregate 20mm nominal size)

including cost of cutting holes and

making good the walls, etc.

(a) For 100mm dia pipe Each 75

(b) For 75 mm dia. Pipe Each 17

26

Providing and fixing single equal plain

junction of required degree with access

door, insertion rubber washer 3mm thick,

bolts and nuts complete

(a)100 x 100 x 100mm Sand cast iron S&S

as per IS - 3989Each 20

27

Providing and fixing single unequal

junction of required degree with access

door, insertion rubber washer 3mm thick,

bolts and nuts complete.

(a)100 x 100 x 75mm Sand cast iron S&S

as per IS - 3989Each 11

28Providing and fixing single equal plain

junction of required degree.

(a)100 x 100 x 100mmSand cast iron S&S

as per IS - 3989Each 2

29Providing and fixing single unequal plain

junction of required degree.

(a)100 x 100 x 75mm Sand cast iron S&S

as per IS - 3989Each 2

30 Providing and fixing terminal guard

(a)100mm Sand cast iron S&S as per IS -

3989Each 7

(b)75mm Sand cast iron S&S as per IS -

3989Each 1

31

Providing lead caulked joints to sand

cast iron/centrifugally cast (spun) iron

pipes and fittings of diameter

(a) 100mm Each 50

(b) 75mm Each 20

32

Providing and fixing M.S. stays and

clamps for sand cast iron/centrifugally

cast (spun) iron pipe of diameter:

(a) 100mm Each 7

(b) 75mm Each 1

Page 39: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

33

Providing and fixing bend of required

degree with access door, insertion rubber

washer 3 mm thick, bolts and nuts

complete.100mmSand cast iron S&S as per IS - 3989 Each 19.00

75mmSand cast iron S&S as per IS - 3989 Each 2.00

34

Provding and fixing sand cast iron trap of

self cleansing design with sand cast iron

screwed down or hinged grating with or

without vent arm complete, including cost

of cutting and making good the wall and

floors.100mm inlet and 75mm outlet Sand cast iron S&S as per IS: 3989.Each 19.00

100mm inlet and 100mm outlet Sand cast iron S&S as per IS: 3989.Each 8.00

35 Providing and fixing collar

100mm Sand cast iron S&S as per IS - 3989Each 6

75mm Sand cast iron S&S as per IS - 3989 Each 1

36

Painting sand cast iron/centrifugally cast

(spun)soil, waste vent pipes and fittings

with paint of any colour such as match

with adjacent wall colour etc., over a coat

of primer (of approved quality) for new

work.100mm dia pipe Metre 135

75mm dia pipe Metre 30

37

Providing and fixing stainless steel kitchen

sink as per IS:13983 with C.I. Brackets and

stainless steel plug 40mm including

painting of fittings and brackets, cutting

and making good the walls wherever

required.Kitchen sink without drain board. 610x510

bowl depth 200mm Each 3

38

Providing and fixing P.V.C. waste pipe for

sink or wash basin including P.V.C. waste

fittings complete

40mm dia Flexible pipe Each 3

(III) Sub-Head-lll

C DRAINAGE

39

Providing and laying non -pressure NP2

class R.C.C. pipes with collars jointed with

stiff mixture of cement mortar in the

proportion of 1:2 including testing of joints

etc. 150 mm dia R.C.C. pipe Metr. 75.00

TOTAL SUB HEAD -ll

Page 40: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

40

Constructing brick masonary manhole in

cement mortar 1:4 (1 cement, 4 coarse

sand.) R.C.C. top slab with1:2:4 mix(1

cement, 2 coars e sand, 4 graded stone

aggregate 20 mm nominal size) foundation

cocrete 1:4:8 mix (1cement, 4 coarse

sand, 8 graded stone aggregate 40 mm

nominal size.) inside plastering 12 mm

thick with cement mortar 1:3 (1 cement, 3

coarse sand.) finished with floating coat of

neat cement and making channels in

cement concrete 1:2:4. finished with

floating coat of neat cement complete as

per standard design.

(a)

Inside size 90x80cm and 45 cm deep

including C.I. cover with frame ( light duty)

455x610 mm internal diamension tatal

weight of cover and fram to be not less

than 38 kg (weight of cover23 kg and

weight of frame 15 kg )

With F.P.S. bricks with class designation

75Each 15.00

(b)

Inside size 120x90cm and 90 cm deep

including C.I. cover with frame (medium

duty) 500mm internal diameter total weight

of cover and fram to be not less than 116

kg (weight of cover 58kg and weight of

frame 58 kg )

With F.P.S. bricks with class designation

75Each 2.00

(IV) Sub-Head-lV(SEPTIC TANK

Septic tank( liquid dimension-4.8X1.8X1.5 cu-m) ,1 Nos.

41

Earthwork in excavation in foundation

trenches or drains including dressing of

sidesand ramming of bottoms,lift upto

1.5m,including getting out the excavated

soil and disposal of surplus excavated as

directed within a lead of 50m

All kind of soil Cum 59.20

42

Supplying and filling in plinth with local

sand and under floors including

watering,ramming consolidating and

dressing complete

Cum 2.38

43

Providing and laying in position concrete of

specified grade excluding the cost of

centring and shuttering all work upto plinth

level

441:2:4(1cement:2 corse sand:4 graded

stone aggregate 20mm nominal sizeCum 2.38

TOTAL SUB HEAD -lll

Page 41: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

45

Brick work with bricks of class designation

100A in foundations and plinth in

Cement morter 1:6(1 cement : 6 corse

sand)Cum 10.72

46 12 mm cement plaster of mix

1:4(1 cement : 4 corse sand) Sqm. 100.61

47 Neat cement punning Sqm. 100.61

48

Brick on edge flooring bricks of class

designation 100a including cement slurry

etc. complete in cement morter

1:6(1 cement : 6 corse sand) Sqm. 16.56

49

Reinforced cement concrete work in

beams,suspended floors roofs,having

slope upto 15, landing,balconies,

shelves,chajjas,lintal,bends,plain window

sills stair case,and spiral staircases up to

floor five level excluding the cost of

centering,shuttering,finishing and

reinforcement with 1:2:4

Cum 3.38

50

Centring and shuttering including strutting

propping etc. and removal of form for

Suspended floors ,roofs,landings,balconies

and access platform Sqm. 15.28

51

Lintels,beams,plinth

bams,griders,bressumers and cantilivers Sqm. 2.25

52Columns,pillars,piers,abutments,posts and

strutsSqm. 6.00

53Supplying and fixing C.I cover without

frame for manholes:

500 mm diameter C.I cover (medium duty)

the weiht of he cover to be not less than 58

kg.

Each 2.00

54

Providing M.S foot rests including fixing in

septic tank with 20 x 20 x 10 cm cement

concrete blocks 1:3:6 ( 1 cement: 3 coarse

sand: 6 graded stone aggregate 20mm

nominal size) as per standard design:

With 20 x 20 mm square bar Each 18.00

55

Providing and fixing s.W intercepting trap

in manholes with stiff mixture of cement

mortar 1:1(1 cement: 1 fine sand) including

testing of joints etc. complete.

150 mm dia Each 2.00

(IV) Sub-Head-E

RAIN WATER PIPES AND FITTINGS

TOTAL SUB HEAD -lV

Page 42: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

56

Providing and fixing on wall face

unplasticised Rigid PVC rain water pipes

conforming to IS:13592 Type A including

jointing with seal ring conforming to

IS:5382 leaving 10mm gap for thermal

expansion.(i) Single socketed pipes

(a) 110 mm diameter Meter 80

(b) 75 mm diameter Meter 20

57

Providing and fixing on wall face

unplasticised - PVC moulded

fittings/accessories for unplasticised Rigid

PVC rain water pipes conforming to

IS:13592 Type A including jointing with

seal ring conforming to IS: 5382 leaving

10mm gap for thermal expansion.

(i) Shoe (Plain)

(a) 110mm Shoe Each 8

(b) 75mm Shoe Each 6

(ii) Single Tee without door

(a) 75x75x75mm Each 14

(iii) Bend 87.5°

(a) 110mm Bend Each 8

(b) 75mm Bend Each 6

58

Providing and fixing unplasticised - PVC

pipe clips of approved design to

unplasticised - PVC rain water pipes by

means of 50 x 50 x 50mm hard wood

plugs, screwed with M.S. screws of

required length including cutting brick work

and fixing in cement mortar 1:4 (1 cement :

4 coarse sand) and making good the wall

etc. complete.(a) 110mm Each 44

(b) 75mm Each 13

59

Providing and fixing to the inlet mouth of

rain water pipe cast iron grating 15 cm

diameter and weighing not less than 440

grams.

Each 14

(V) Sub-Head-V

E WATER SUPPLY

TOTAL SUB HEAD -lV

Page 43: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

60

Constructing masonry chamber 30x30x50

cm, inside with 75 class disignation brick

work in cement mortar 1:5 (1 cement :5

fine sand) for stop cock, with C.I. surface

box 100x100x75 mm with hinged cover

fixed in cement concrete slab 1:2:4 mix (1

cement :3 coarsesand :4 graded stone

aggregate 20 mm nominal size) necessary

sand :4 draded stone aggregate 20 mm

nominal :5 fine sand :10 graded stone

aggregate 40mm nominal size) and inside

plastering with cement mortar 1:3 (1

cement :3 coarse sand) 12 mm thick

finished with a floating coat of neat cement

complete as per standard disign.

With F.P.S. bricks Each 1.00

(VII) Sub-Head-Vl

G DRAINAGE

61

Making soak pit 2.5 m diameter 3.0 meter

deep with 45x45 cm dry brick honey comb

shaft with brick of class designation 75 and

S.W. drain pipe 100 mm diameter, 1.8 m

long complete as per standard design.

With F.P.S. bricks Each 1.00

62

Providing and fixing square mouth SW

gully trap grade A complete with CI grating

brick masonry chamber with water tight CI

cover with frame of 300X300mm

size(inside) the wt. of cover to be not less

than4.50kg. And frame to not less than

2.70 kg. as/standard design

150x100mmsize p type

With F.P.S. bricks designation 75 Each 1.00

63

Constructing brick masonry road gully

chamber 45X45X77.5 cm with bricks of

class designation 75 in cement mortar 1:4

including 500 X 450 mm pre cast RCC

vertical grating complete as per standard

designwith FPS bricks each 1

H SUB HEADVLL (TUBEWELL)

TOTAL SUB HEAD -Vl

TOTAL SUB HEAD -V

Page 44: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

64

Providing all materials labour for drilling by

reverse Rotary rig machine for following

diameter of bore hole in all kinds of soil

mixed with kankar, sand and stone

including providing sample box and

collection strata sample of every 10'-0"

depth of drilling for accortaining proper

equiler for completing 300mmx200mm dia

high yielding tube well complete as per

P.H.E.D. spicifications

250 mm dia bore from 0 to 30 mtrs Mtrs. 30

250 mm dia bore from 30 to 60 mtrs Mtrs. 30

250 mm dia bore from 60 to 90 mtrs Mtrs. 30

250 mm dia bore from 90 to 120 mtrs Mtrs. 30

65

Supplying all materials such as following

sizes of PVC pipe with socket and

providing equipment and labour for

lowering the following pipe and cutting the

pipe to required size as per approved assly

and strata chart as required all complete

as per direction of E/I.

110 mm dia PVC. Pipe mtrs. Mtrs. 30

75 mm dia PVC. Pipe mtrs. Mtrs. 45

75 mm dia PVC.slotted Pipe mtrs. Mtrs. 30

66

Supplying the following fitting and fixing

the same in position as per approved

lowering assembly and strata chart

including providing all equipment on

process of lowering the assly etc.all

complete as per direction of E/I.

110X 75 mm dia PVC Reducer. Each 1

75 mm dia PVC. Well plug. Each 1

Solvent Cement. Kg 1

75 mm dia steed cap Each 1

GI wire 14 nos Kg 8

67

Supplying all materials labour and tools for

fitting tube well with pea graved of

dalbhumgarh of size 4 mm to 8 mm

including carriage, washing and placing

the same in position around the tube well

as per direction of E/I. Market Rate

cft 200

68

Supplying all equipments, tools and labour

and developing the tube well by air

compressor for continuous 8 hrs. till sand

free discharge of tube well as various

depth all complete as per direction of E/I.

Market Rate

Hrs 8

Page 45: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

69

Transportation cost for rig machine and

other accessories materials and

equipments including development unit

etc. To tube well site till complete of work

and returning back etc. all

complete.Market rate

L.S. 1

70

Supplying all materials and labour for

arrangement for additional water required

during drilling period. Market rate.L.S. 1

71Establishment of -2HP of submersible

pump set (detail attchhed)each 1

SL No Description Unit Quantity Rate Amount

1 ROAD & PAVING WORK

Earth work in excavation by mechanical

means (Hydraulic excavator) / manual

means over areas (exceeding 30cm in

depth. 1.5m in width as well as 10 sqm on

plan) including disposal of excavated

earth, lead upto 50m and lift upto 1.5m,

disposed earth to be levelled and neatly

dressed.All kind of soil Cum 50.0

2 Filling available excavated earth (excluding

rock) in trenches, plinth, sides of

foundations etc. in layers not exceeding

20cm in depth, consolidating each

deposited layer by ramming and watering,

lead up to 50 m and lift upto 1.5 m.

All kind of soil cum 950.0

3 Banking excavated earth in layers not

exceeding 20 cm. in depth, reaking clods,

watering, rolling each layer with ½ tonne

roller, or wooden or steel rammers, and

rolling every 3rd and top-most layer with

power roller of minimum 8 tonnes and

dressing up, in embankments for roads,

flood banks, marginal banks, and guide

banks etc., lead upto 50 m and lift upto 1.5

m.All kind of soil cum 150

Total Vll

Total Sub head C -

CIVIL ITEMS SUB HEAD D (SITE DEVELOPMENT & BOUNDARY WALL)

Page 46: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

4 Providing & laying in position cement

concrete of specified grade excluding the

cost of centring and shuttering -All works

upto plinth level:

1:3:6 (1 cement: 3 coarse sand: 6 graded

stone aggregate 20 mm nominal size) cum 8

5 Earth work in rough excavation , banking

excavated earth in layer notexceeding 20

cm in depth , breaking clods watering ,

rolling each layer with 1/2 tonne roller or

wooden or steel rammers and rolling every

3rd and top-most layer with power roller of

minimum 8 tonnes and dressing up in

embankments for roads, flood banks ,

marginal banks and guide banks or filling

up ground depressions. lead upto 50 m

and lift upto 1.5m.

All Kinds of soil cum 105

6 Construction of granular sub-base by

providing close graded Material

conforming to specifications, mixing in a

mechanical mix plant at OMC, carriage of

mixed material by tippers to work site, for

all leads & lifts, spreading in uniform layers

of specified thickness with motor grader on

prepared surface and compacting with

vibratory power roller to achieve the

desired density, complete as per

specifications and directions of Engineer-in-

Charge.With material conforming to Grade-

II (size range 53 mm to 0.075 mm ) having

CBR Value-25.

cum 8.25

7 Providing and laying 60mm thick factory

made cement concrete interlocking paver

block of M -30 grade of approved shape &

Size made by block making machine with

strong vibratory compaction and of

approved size and design/ shape laid in

required colour and pattern over and

including 50mm thick compacted bed of

course sand, filling the joints with coarse

sand etc. all complete as per the direction

of Engineer-in-charge.

Sqm 225

Page 47: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

8 Providing and laying 60mm thick factory

made cement concrete interlocking grass

paver block of M 30 grade approved shape

& Size made by clock making machine

with strong vibratory compaction and of

approoved size and design/shape laid in

required colour & pattern over and

including 50mm thick compacted bed of

course sand, filling the joints with course

sand etc. all complete as per the direction

of Engineer-in-Charge

Sqm 400

9 Providing and faying cement concreate in

kerbs, steps and the like at or near ground

level excluding the cost of centring,

shuttering and finishing.

1:3:6 (1 Cement:3 coarse sand:6 graded

stone aggregate 20

mm nominal size)

cum 10

10 Brick work with bricks of class designation

100B in foundations and plinth in ::

Cement mortar 1:6 (1 cement : 6 coarse

sand)

Cum76

12 mm cement plaster of mix :1:6 (1

cement: 6 fine sand) sqm 142.5

Applying one coat of white cement primer

of approved brand and manufacture on

exterior wall surface:

sqm 57

Finishing walls with water proofing cement

paint(Snowcem) of approve brand and

manufacture and of required shade to give

an even shade new work (Three or more

coat).

sqm 57

TOTAL OF ROAD WORK CARRIED

OVER TO SUMMARY OF CIVIL WORKS

BOUNDARY WALL & GATE HOUSE

11 Earth work in excavation by mechanical

means (Hydraulic excavator) / manual

means in foundation trenches or drains

(not exceeding 1.5 m in width or 10 sqm on

plan) including dressing of sides and

ramming of bottoms, lift upto 1.5 m,

including getting out the excavated soil

and disposal of surplus excavated soil as

directed, within a lead of 50 m.

All kind of soil Cum 210

Page 48: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

12 Filling available excavated earth (excluding

rock) in trenches, plinth, sides of

foundations etc. in layers not exceeding

20cm in depth, consolidating each

deposited layer by ramming and watering,

lead up to 50 m and lift upto 1.5 m.

Cum 120

13 Providing & laying in position cement

concrete of specified grade excluding the

cost of centring and shuttering -All works

upto plinth level:1:3:6 (1 cement: 3 coarse sand: 6 graded

stone aggregate 20 mm nominal size) cum 26

14 Providing and laying in position machine

batched and machine mixed design mix M-

25 grade cement concrete for reinforced

cement concrete work, using cement

content as per approved design mix,

including pumping of concrete to site of

laying but excluding the cost of centering,

shuttering, finishing and reinforcement,

including admixtures in recommended

proportions as per IS: 9103 to accelerate,

retard setting of concrete, improve

workability without impairing strength and

durability as per direction of Engineer-in-

charge.

(Note :- Cement content considered in this

item is @ 330 kg/cum. Excess/less cement

used as per design mix is

payable/recoverable separately).All works upto plinth level. cum 6.5

All works above plinth level upto Roof

Floor.cum 1.5

Walls columns, pillars, posts cind strutscum 11

Beams, planth beams, girders,

bressumers, contilevers,Suspended floors

lintels roofs and staircases includingspiral

staircases, shelves etc.

cum 27

15 Steel reinforcement for R.C.C. work

including straightening, cutting, bending,

placing in position and binding all complete

upto plinth level.Thermo-Mechanically Treated bars TMTC-

500-6mm dia.kg 510

Thermo-Mechanically Treated bars TMTC-

500-8mm dia.kg 800

Thermo-Mechanically Treated bars TMTC-

500-10mm dia.kg 1110

Thermo-Mechanically Treated bars TMTC-

500-12mm dia.kg 1050

Page 49: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

16 Centering & shuttering including strutting,

propping etc.& removal of form (staging

height upto 4.2m) for:

Foundations, footings, bases of columns

etc. for mass concrete.sqm 325

Columns, pillars, piers, abutments, posts &

struts.sqm 276

Suspended floors, roofs, landings,

balconies & access plateform.sqm 15

Lintels, beams, plinth beams, girders,

bressumers & cantilevers.sqm 3

17 Brick work with common burnt clay F.P.S.

(non modular) bricks of class designation

7.5 in superstructure above plinth level up

to floor V level in all shapes and sizes in

:Cement mortar 1:6 (1 cement : 6 coarse

sand)

cum 98

18 Making plinth protection 50mm thick of

cement concrete 1:3:6 (1 cement :3 coarse

sand : 6 graded stone aggregate 20 mm

nominal size) over 75mm thick bed of dry

brick ballast 40 mm nominal size, well

rammed and consolidated and grouted

with fine sand including finishing the top

smooth

sqm 15

19 12 mm cement plaster of mix :1:6 (1

cement: 6 fine sand) sqm 1325

20 6 mm cement plaster of mix :1: 3 (1

cement: 3 fine sand)sqm 20

21 Brick Flat soiling :- Providing designation

100 B one brick flat soling joints filled with

local sand including cost of watering,

taxes, royalty all complete as per building

specification and direction of E/l,

sqm 15.0

22 P.C.C Flooring:- 40mm Th cement

concrete flooring 1:2:4(1Cement:2

Coarse:4 Grade stone aggregate)finished

with a floating coat of neat cement

including cement slurry etc.

sqm 15

23 Skirting :- 18mm Th Cement plaster

skirting (up to 15 Cm height) with cement

mortar 1:3(1Cement : 3 coarse sand )

finished with a floating coat of neat cement

.

sqm 8

Page 50: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

24 Door chowkhat :-Providing and fixing

pressed steel door frame confirming IS

code 351 manufactured from commerical

mild steel sheet of 1.25 mm thickness

including hinges, jamb, lock jamb, bead

and if required angle threshold of mild

steel angle of section 50 x 25 mm or base

ties of 1.25mm pressed mild steel welded

or rigidly fixed together by . mechnical

means, adjustable lugs with split end tail to

each jamb including steel butt hinges 2.5

mm thick with mortar guards, lock strike-

plate and shock absorbers as specified

and applying a coat of approved steel

primer after pre-treatment of the surface as

directed by Engineer-in-charge:

Profile C

meter 5.5

25 Providing and fixing 1mm thick M.S. sheet

door with frame of 40x40x6mm angle iron

and 3mm M.S. gusset plates at the

junctions and corners, all necessary fittings

complete, including applying a priming

coat of approved steel primer.Using M.S.

angels 40x40x6 mm for diagonal braces.

sqm 2.1

26 Providing and fixing M.S. grills of

requirement pattern in frames of windows

etc. with M.S. flats bars 5mm Th & 20mm

wide or 10mm x 10mm square bars @

100mm C/C Vertical /horizontal etc.all

complete, fixed to openings/wooden

frames with rawl plugs screws etc.

kg 550

27 Steel glazed window :- Providing and

fixing steel glazed windows and ventilatrs

of standard rolled steel sections, joints

mitered and welded with 15x3 mm lugs 10

cm long with steel lugs embedded in

cement concrete blocks 15x10x10 cm of

1:3:6(1 cement: 3 coarse sand : 6 graded

stone aggregate 20 mm nominal size) or

with woodenplugs and screws or rawl

plugs and screws or with fixing clips or

with bolts and nuts as required, including

providing and fixing of glass panes with

glazing clips and special metal-sash putty

of approved make complete including

applying a priming coat of approved steel

primer; excluding the cost of metal beading

and other fitting except necessary hinges

or pivots as required.

Sqm 3

Page 51: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

28 Providing and fixing M.S.fan clamp type 1

of 16 mm dia.M.S. bar bent to shape with

hooked ends in R.C.C slabs during laying

including painting the exposed portion of

loop,all as per standard design complete.

each 1

29 Providing and fixing circular cast iron box

for ceiling fan clamp 140 mm internal dia,

73 mm height, 5 mm thick rim bottom and

top lids, 1.5 mm thick M.S sheet with its

top surface hacked for proper bonding top

lid shall be screwed into the cast iron box

by means of 3.3 mm dia round headed

screws, one ;pcf at the corners. Clamps

shall be made of 12 mm dia M.S. bar bent

to shape as per standard drawing.

each 1

30 Applying one coat of white cement primer

of approved brand and manufacture on

exterior wall surface:

sqm 1350

31 Finishing walls with water proofing cement

paint(Snowcem) of approve brand and

manufacture and of required shade to give

an even shade new work (Three or more

coat).

sqm 1350

32 Distempering with dry distemper of

approved brand and manufacture

(Ashian/Berger/) two or more coats and of

required shade on new work ,over and

including primimn coat of whiting to given

an even shade.

sqm 30

33 With ready mixed zinc chromate yellow

primer of approved brand and manufacture

on steel galvanized iron/steel workssqm 15

34 Painting with synthetic enamel paint of

approved brand and manufacture with

enamel putty in all shades to give an even

shade New steel work (two or more coats)

sqm 15

Page 52: BANK OF BARODA · 2018-02-13 · exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated

35 Providing and fixing concertina coil fencing

with punched tape concertina coil 600 mm

dia 10 metre openable length ( total length

90 m) having 50 nos rounds per 6 metre

length, upto 3 m height of wall with existing

angle iron 'Y' shaped placed 2.4 m or 3.00

m apart and with 9 horizontal R.B.T.

reinforced barbed wire, stud tied with G.I.

staples and G.I. clips to retain horizontal

including necessary bolts or G.I. barbed

wire tied to angle iron all complete as per

direction of Engineer-in-charge with

reinforced barbed tape(R.B.T.) / Spring

core (2.5mm thick) wire of high tensile

strength of 165 kg/ sq.mm with tape (0.52

mm thick) and weight 43.478gm/ metre

(cost of M.S. angle, C.C. blocks shall be

paid separately)

Rmt 270

TOTAL OF BOUNDARY WALL & GATE

HOUSE WORK CARRIED OVER TO

SUMMARY OF CIVIL WORKS

TOTAL SUB HEAD (A+B+C+D)

SUMMARY

TOTAL CIVIL WORK (Building) Sub Head A

TOTAL SITE DEVELOPMENT & BOUNDARY WALL SUB HEAD -D

Grand total:-

Total Sub head D :-

TOTAL INTERNAL ELECTRICAL WORK SUB HEAD-B

Total Above

Grand total-

TOTAL P.H.E WORK SUB HEAD-C