8
75.5886.02 BR2-900 20180404 Page 1 of 8 1. Power input 2. Relay outputs 3. Day/Night input 4. AUX input 5. Learn buttons 6. DIP-switches 7. Potentiometers 8. Radio frequency LED (red) 1 2 12 9. Relay 2 LED (white) 10. Relay 1 LED (blue) 11. Tri-color signal strength LED 12. Antenna 3 4 11 10 9 8 10TD900HH4: 4-button transmitter 10TD900HH3: 3-button transmitter 10TD900HH2: 2-button transmitter 10TD900HH1: 1-button transmitter 10TD900PB: Push Plate transmitter 10TD900TR: Touchless Retrofit transmitter 10TD900HH1U: 1-button Universal transmitter 5 6 7 2 Relay Logic Module with Built-In 900 MHz Wireless Technology (US version) DESCRIPTION HAND-HELD TRANSMITTERS BR2-900 ENGLISH

BR2-900 · 2019-09-25 · 75.5886.02 BR2-900 20180404 Page 3 of 8 USER INTERFACE DIP switches can be set to achieve desired functionality based upon specific application requirements

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BR2-900 · 2019-09-25 · 75.5886.02 BR2-900 20180404 Page 3 of 8 USER INTERFACE DIP switches can be set to achieve desired functionality based upon specific application requirements

75.5886.02 BR2-900 20180404 Page 1 of 8

1. Power input2. Relay outputs3. Day/Night input4. AUX input

5. Learn buttons6. DIP-switches7. Potentiometers8. Radio frequency LED (red)

1

2

12

9. Relay 2 LED (white)10. Relay 1 LED (blue)11. Tri-color signal strength LED12. Antenna

3 4

11 10

9 8

10TD900HH4: 4-button transmitter10TD900HH3: 3-button transmitter10TD900HH2: 2-button transmitter10TD900HH1: 1-button transmitter

10TD900PB: Push Plate transmitter

10TD900TR: Touchless Retrofit transmitter

10TD900HH1U: 1-button Universal transmitter

5 6

7

2 Relay Logic Module with Built-In 900 MHz Wireless Technology

(US version)

DESCRIPTION

HAND-HELD TRANSMITTERS

BR2-900

ENG

LISH

Page 2: BR2-900 · 2019-09-25 · 75.5886.02 BR2-900 20180404 Page 3 of 8 USER INTERFACE DIP switches can be set to achieve desired functionality based upon specific application requirements

Page 2 of 8 75.5886.02 BR2-900 20180404

Shut off all power going to header before attempting any wiring procedures.

Maintain a clean and safe environment when working in public areas.

Constantly be aware of pedestrian traffic around the door area.

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.

ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board, ensure you dissipate your body’s ESD charge.

Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment.

Ensure compliance with all applicable safety standards (e.g. ANSI A156.10) upon completion of installation.

DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair may:

1. jeopardize personal safety and may expose one to the risk of electrical shock.2. adversely affect the safe and reliable performance of the product resulting in a voided warranty.

PRECAUTIONS

INSTALLATION

Relays 1 and 2 are DPDT: relays 1A and 1B fire simultaneously and relays 2A and 2B fire simultaneously.

Relays 1B and 2B are commonly used in applications with two (2) locking devices and/or with two (2) independent door controls.

INPUT D/N (DAY/NIGHT mode)when open, allows transmitters learned in both SECURE mode and UNSECURE mode to functionwhen closed, only allows transmitters learned in UNSECURE mode to function

INPUT AUX functions regardless of learn, DIP switch, or potentiometer settings.

Wiring

Page 3: BR2-900 · 2019-09-25 · 75.5886.02 BR2-900 20180404 Page 3 of 8 USER INTERFACE DIP switches can be set to achieve desired functionality based upon specific application requirements

75.5886.02 BR2-900 20180404 Page 3 of 8

USER INTERFACE

DIP switches can be set to achieve desired functionality based upon specific application requirements.

Potentiometers control output relay functionality.

900 MHz wireless transmitters can be programmed (or "learned") as either UNSECURE or SECURE transmitters. Any combination of up to 75 transmitters may be programmed.

Pressing and holding transmitter button for three (3) seconds activates signal strength LED on Br2-900.

DIP-Switches

DIP STATUS FUNCTION DESCRIPTION

1

STDstandard

modeallows only learned/programmed transmitters to function

UNI1universal mode2 allows learned/programmed and "universal transmitters" to function

2

STDstandard

modepressing/holding or pressing/releasing transmitter activates and holds relay according to HOLD TIME POTs (single shot)

EHextended

holdpressing/holding transmitter holds relay as long as transmitter is pressed/held – once released, relay acts according to HOLD TIME POTs

NOTES:1. Day/Night mode does not function when DIP-switch 1 is set to UNI.2. See Universal Mode in SET-UP section (page 5).

Potentiometers

Learn Buttons

BUTTON FUNCTION DESCRIPTION

UNSECURE unsecure transmitters learned transmitter functions when INPUT D/N is open or closed

SECURE secure transmitters learned transmitter only functions when INPUT D/N is open

POT FUNCTION DESCRIPTION

HOLD 1 relay 1 hold time 0.5 – 10 seconds

HOLD 2 relay 2 hold time 0.5 – 10 seconds

DELAY delay between relay 1 and relay 2 0 – 30 seconds

Signal Strength Indicator

LED COLOR DESCRIPTION

GREEN strong wireless signal

YELLOW moderate wireless signal

RED weak wireless signal

Page 4: BR2-900 · 2019-09-25 · 75.5886.02 BR2-900 20180404 Page 3 of 8 USER INTERFACE DIP switches can be set to achieve desired functionality based upon specific application requirements

Page 4 of 8 75.5886.02 BR2-900 20180404

1 2 3

41

1

2

2

3

3

4

4

A A

B B

C C

D D

100 ENTERPRISE DRIVEPITTSBURGH, PA 15275(800) 523-2462

TITLE:PART NUMBER:

DRAWN BY:

CHECKED BY:

RELEASED:DRAWING NUMBER:

BEA, INC.4.5" Square Text Only Pushplate

10PBS45

kjgierl

4/4/200310PBS45

34.43[ mm]1.36"

114.

30[

mm

]4.

5"

114.30[ mm]4.5"

21 3

Connect transmitter1 to push plate (NO and COM) and insert into box.

Follow steps 1 – 4 in Hand-Held Configuration above.

Install push plate.

Universal transmitters (10TD900HH1U) do not need programmed (or "learned") to the Br2-900. Their unique serial number is automatically recognized by the Br2-900.

During the Hand-Held Configuration or the Push Plate Configuration steps (above), standard transmitters must be programmed/learned as either "Secure" or "Unsecure" transmitters. When set to Universal, learned, standard transmitters will function as programmed/learned.

Set DIP-switches as desired.For DIP-switch settings, please refer to table on page 3.

Press transmitter twice (white and blue LEDs on receiver will illuminate).

Press and release desired Learn button (red LED on Br2-900 will illuminate).

Adjust POTs as desired.See page 3 for descriptions.

see hub image on page 1

Push Plate Configuration

Hand-Held Configuration

NOTES:1. 10TD900PB required for push plates.

Universal Mode

SET-UP

R1 R2 DELAY

Page 5: BR2-900 · 2019-09-25 · 75.5886.02 BR2-900 20180404 Page 3 of 8 USER INTERFACE DIP switches can be set to achieve desired functionality based upon specific application requirements

75.5886.02 BR2-900 20180404 Page 5 of 8

Vestibule applications may be installed and programmed so that either door 1 and door 2 open simultaneously or door 1 opens first and door 2 opens after a delay (set by HOLD TIME potentiometers).

For 2-way traffic, two (2) Br2-900 modules are required.

Vestibule Configuration

1-Way Traffic (simultaneous)

Door 1 and Door 2 will open simultaneously.

1-Way Traffic (sequence)

Door 1 will open and then Door 2 will open after a delay set by DELAY POT.

1-Way Traffic (lock + simultaneous)

Lock(s) will unlock and then Door 1 and Door 2 will open simultaneously.

2-Way Traffic

Door 1 will open and then Door 2 will open after a delay set by DELAY POT.

Door 2 will open and then Door 1 will open after a delay set by DELAY POT.

SET-UP (CONT.)

Page 6: BR2-900 · 2019-09-25 · 75.5886.02 BR2-900 20180404 Page 3 of 8 USER INTERFACE DIP switches can be set to achieve desired functionality based upon specific application requirements

Page 6 of 8 75.5886.02 BR2-900 20180404

1

x2

2

1

1

3 V

2

AA

A B

atte

ry

AA

A B

atte

ry

1

Press BOTH learn buttons until red LED flashes once (~2 s).

Press BOTH Learn buttons until blue LED illuminates (~10 s).

Press transmitter TWICE within 10 seconds.

Remove back screws and disassemble.

Replace 2 AAA batteries observing polarity.

Replace 3 volt (CR2032) battery observing polarity and reassemble.

Low Battery Indicator: After transmitter button is pressed, low battery is indicated by three (3) transmitter red LED blinks.

Single Transmitter

REMOVING TRANSMITTERS

All Transmitters

BATTERY REPLACEMENT

Hand-held (TD900HHx)

Push Plate (TD900PB)

Page 7: BR2-900 · 2019-09-25 · 75.5886.02 BR2-900 20180404 Page 3 of 8 USER INTERFACE DIP switches can be set to achieve desired functionality based upon specific application requirements

75.5886.02 BR2-900 20180404 Page 7 of 8

TROUBLESHOOTING

Br2-900 will not react to any inputs

Incorrect power Verify power supply of 12 – 24 VAC/VDC ±10% is wired to correct terminals.

Not programmed Ensure a Br2-900 is programmed with wireless transmitter.

Incorrect wiring Verify wiring.

Defective Br2-900 Replace Br2-900.

Br2-900 has no output

Incorrect output devices Ensure proper devices are connected to outputs.

Incorrect wiring Verify wiring.

Incorrect settings Verify programming and potentiometer settings.

Defective Br2-900 Replace Br2-900.

Red LED on receiver flickering; unable to program

Push Plate is stuck Disconnect push plates to determine which one is stuck (LED should go out).

Faulty transmitter If LED does not go out, remove transmitter batteries to determine which is faulty, replace transmitter.

Weak signal Antenna positioned poorly Position antenna outside of door header.

TECHNICAL SPECIFICATIONS

Supply voltage: 12 – 24 VAC / VDC ±10%

Current consumption: 45 mA DC75 mA AC

Frequency: 908 – 918 MHz (frequency hopping)

Emitted radio power: -25 dBm (TX)

Power consumption: 0.5 – 1.5 W

Transmitter capacity (per receiver):Programmable (standard):Universal:

75unlimited

Temperature rating: -22 – 158 °F (-30 – 70 °C)

Input Day / Night (24hr) AUX

DRY contactDRY contact

Contact rating: Relay 1 DPDT / Relay 2 DPDT: 2 A @ 30 VDC or 2 A @ 24 VAC

LEDs: blue (relay 1 activation)white (relay 2 activation)red (radio frequency / learn)tri-color (signal strength)

Certification: FCC, IC

Dimensions: 5.2" (W) x 1" (H) x 2.2" (D) (133 mm x 25 mm x 55 mm)

Housing: ABS (white translucent)

Specifications are subject to change without prior notice.All values measured in specific conditions.

Page 8: BR2-900 · 2019-09-25 · 75.5886.02 BR2-900 20180404 Page 3 of 8 USER INTERFACE DIP switches can be set to achieve desired functionality based upon specific application requirements

Page 8 of 8 75.5886.02 BR2-900 20180404

“This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.”

Changes or modifications not expressly approved by BEA Incorporated could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

FCC ID: 2ABWS-10BR2900 IC: 4680A-10BR2900 MODEL: 10BR2900

FCC ID: 2ABWS-10TD900PB IC: 4680A-10TD900PB MODEL: 10TD900PB

FCC ID: 2ABWS-10TD900HH4 IC: 4680A-10TD900HH4 MODEL: 10TD900HH1

FCC ID: 2ABWS-10TD900HH4 IC: 4680A-10TD900HH4 MODEL: 10TD900HH2

FCC ID: 2ABWS-10TD900HH4 IC: 4680A-10TD900HH4 MODEL: 10TD900HH3

FCC ID: 2ABWS-10TD900HH4 IC: 4680A-10TD900HH4 MODEL: 10TD900HH4

FCC ID: 2ABWS-10TD900HH1U IC: 4680A-10TD900HH1U MODEL: 10TD900HH1U

FCC / IC

BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA does not guarantee any use of the sensor outside of its intended purpose.

BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for the type of door/gate system.

Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor system installation is compliant with local, national, and international regulations, codes, and standards.

Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL 325).

Verify that all appropriate industry signage and warning labels are in place.

BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS

PLEA

SE K

EEP

FOR

FURT

HER

USE

– D

ESIG

NED

FO

R C

OLO

R PR

INTI

NG

Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462General Tech Questions: [email protected] | Tech Docs: www.BEAinc.com

©BE

A |

Orig

inal

Inst

ruct

ions

|75

.588

6.02

BR2

-900

201

8040

4