CableListe_RNC2600_RU40

  • Upload
    bdtptit

  • View
    213

  • Download
    0

Embed Size (px)

Citation preview

  • 8/9/2019 CableListe_RNC2600_RU40

    1/48

     

    WCDMA RAN, Rel. RU40,

    Operating Documentation 

    Cable Lists for RNC2600

    DN0938288

    Issue 02D

    Approval Date 2012-10-22

  • 8/9/2019 CableListe_RNC2600_RU40

    2/48

    Cable Lists for RNC2600

    2 (48) © Nokia Siemens Networks DN0938288Issue 02D

    The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended forthe use of Nokia Siemens Networks customers only for the purposes of the agreement underwhich the document is submitted, and no part of it may be used, reproduced, modified or

    transmitted in any form or means without the prior written permission of Nokia SiemensNetworks. The documentation has been prepared to be used by professional and properlytrained personnel, and the customer assumes full responsibility when using it. Nokia SiemensNetworks welcomes customer comments as part of the process of continuous developmentand improvement of the documentation.

    The information or statements given in this documentation concerning the suitability, capacity,or performance of the mentioned hardware or software products are given “as is” and allliability arising in connection with such hardware or software products shall be definedconclusively and finally in a separate agreement between Nokia Siemens Networks and thecustomer. However, Nokia Siemens Networks has made all reasonable efforts to ensure thatthe instructions contained in the document are adequate and free of material errors andomissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks,explain issues which may not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO

    EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TOSPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES,SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESSINTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THEUSE OF THIS DOCUMENT OR THE INFORMATION IN IT.

    This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademarkof Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.

    Copyright © Nokia Siemens Networks 2013. All rights reserved.

  • 8/9/2019 CableListe_RNC2600_RU40

    3/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 3 (48) 

    Contents

    Introduction .......................................................................................... 6 

    1.1 

    Numbering of the subrack shelves and cable connectors ....................... 6 1.2

     

    Locking pegs .......................................................................................... 8 

    1.3 

    Categories of cables .............................................................................. 8 

    1.3.1 

    Interconnection cables ........................................................................... 8 

    1.3.2 

    Site cables ............................................................................................. 9 

    1.4 

    Identifying cables ................................................................................. 10 

    1.5 

    Cabling lists ......................................................................................... 12 

    1.6  Physical cable equipping positions and SW port connectiondesignation .......................................................................................... 13

     

    Intra-cabinet cables for the RNAC cabinet ....................................... 16 

    2.1 

    RNAC power and fan tray control cables.............................................. 16 

    2.2 

    RNAC HMS and timing bus cables ....................................................... 17 

    2.3 

    RNAC synchronization and LVDS cables ............................................. 23 

    2.4 

    RNAC LAN cables ............................................................................... 25 

    2.5 

    RNAC alarm and synchronization cables ............................................. 26 

    2.6 

    RNAC protection switch cables ............................................................ 29 

    2.7 

    RNAC PCIe and Mini SAS cables ........................................................ 30 

    2.8 

    L3 Data Collector Cables for RNAC cabinet ......................................... 31 

    Intra-cabinet cables for the RNBC cabinet ....................................... 32 

    3.1 

    RNBC power and fan tray control cables.............................................. 32 

    3.2 

    RNBC HMS bus and timing bus cables ................................................ 33 

    3.3  RNBC protection switch cables ............................................................ 36 3.4

     

    L3 Data Collector Cables for RNBC cabinet ......................................... 38 

    Inter-cabinet cables from RNBC to RNAC ........................................ 40 

    4.1 

    Inter-cabinet HMS and timing cables .................................................... 40 

    4.2 

    Inter-cabinet SWU LAN cables ............................................................. 45 

    4.3 

    Inter-cabinet SFU LVDS lines .............................................................. 46 

  • 8/9/2019 CableListe_RNC2600_RU40

    4/48

    Cable Lists for RNC2600

    4 (48) © Nokia Siemens Networks DN0938288Issue 02D

    Summary of changes

    Changes between document issues are cumulative. Therefore, the latestdocument issue contains all changes made to previous issues.

    Note that our issue numbering system, safety information, and productnaming practice are changing. For more information, see Guide toWCDMA RAN Operating Documentation.

    Changes between issues 02C (2012-02-09, RU30) and 02D (2012-10-22, RU30)

    Notes on timing bus cable “daisy chain” and “star” configurations areadded.

    Inter-cabinet HMS and timing cables (4.1)

    - A discussion on “daisy chain” cabling in RNC450 and RNC2600 isadded.

    - A new table, Timing cables from RNBC to RNAC: “daisy chain” , isadded.

    Changes between issues 02B (2011-06-09, RU30) and 02C (2012-02-09, RU30)

    The description part in this document is updated.

    Introduction (1)

    - Previous chapter 1 About Cable Lists for RNC450, chapter 2 Identifyingsubracks, connectors and cables, and chapter 3 Physical cable equippingpositions and SW port connection coordinates are combined to currentchapter 1 Introduction.

    Intra-cabinet cables for the RNAC cabinet (2.8)

    - Previous section of 6.1 L3 Data Collector Cables for RNAC cabinet iscombined to this chapter.

    Intra-cabinet cables for the RNBC cabinet (3.4)

    - Previous section of 6.2 L3 Data Collector Cables for RNBC cabinet iscombined to this chapter.

    Inter-cabinet HMS and timing cables (4.1)

    - In figure 9 Routing of HMS cables, it is corrected that the cable from RNACsubrack 2 to RNBC subrack 1 is removed.

  • 8/9/2019 CableListe_RNC2600_RU40

    5/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 5 (48) 

    Changes between issues 02A (2011-03-01, RU30) and 02B (2011-06-09, RU30)

    Inter-cabinet HMS and timing cables (5.1)

    - The table of Inter-cabinet HMS and timing cables from RNAC toRNBC  is updated. The inter-cabinet timing cables are from RNAC toRNBC with default and optional situations.

    - Figure 10 Routing of Inter-cabinet timing cables is added. 

  • 8/9/2019 CableListe_RNC2600_RU40

    6/48

    Cable Lists for RNC2600

    6 (48) © Nokia Siemens Networks DN0938288Issue 02D

    1 Introduction This document provides lists of the Inter-cabinet and Intra-cabinet cablesinstalled in RNAC and RNBC cabinets in RNC2600.

    For more detailed information on RNC cabinet mechanics, see 

    Equipment Lists for RNC2600 .

    For basic information on, for example, RNC installation planning, see IPA-RNC Engineering Description. 

    For detailed information on RNC hardware installation, see Installing theMGW and IPA-RNC.

    In RNC2600, the intra-cabinet timing bus cables, as well as the inter-cabinet HMS and timing cables, may follow either the “daisy chain” orthe “star” topology. The configuration must be uniform between RNACand RNBC. This cable list follows the “star” topology. For information on

    the “daisy chain” topology, see Cable Lists for RNC450 .

    1.1 Numbering of the subrack shelves and cableconnectors

    The equipment cabinets, subrack positions, and subrack cableconnectors are numbered in a way to aid installation.

    The subrack positions of the cabinet are assigned with numbers from 1

    to 4 from the top down. The subrack is identified by a sticker attached toits upper left corner.

     As you can see in below figure, each subrack has 20 slots. The slotnumber is marked in front side of subrack. Slot 1 to 18 are full-heightplug-in units. Slot 19 and 38 are half-height plug-in units.

  • 8/9/2019 CableListe_RNC2600_RU40

    7/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 7 (48) 

    IPA2800 RNC / MGW cabinet,seen from the front

    Slot position number 

    CA_020 OMU 0 1.0B 16.4X WDU 0-0 1.0B 17.3H CJA002 SCSI bus 0

    CA_021 OMU 0 1.0B 16.5D WDU 0-0 1.0B 17.3O CJB002 SCSI bus 0

    FU Connector FU Connector Type Use

    Equip No. CABLE FROM CABLE TO

    Connector Type ACE

    1.0B 16.4X

    1 2 3F = FRONTB = BACK 4

    DN05158647

    Subrack in position 1 seen from the rear 

     A

    C

    E

    G

    J

    L

    N

    P

    R

    T

    V

    X

    Z

    Z ABCDEF

    3

    1

    2

    3

    4

    5

    B

     A

    B

     A

    B

    Connector Type BDF

    B

    D

    F

    H

    K

    M

    O

    Q

    S

    U

    W

    Y

    Z ABCDEF

    4

    12345678910111213141516171819

    2

    Note

    1

     

    Figure 1 Notations used in the cabling lists

  • 8/9/2019 CableListe_RNC2600_RU40

    8/48

    Cable Lists for RNC2600

    8 (48) © Nokia Siemens Networks DN0938288Issue 02D

    1.2 Locking pegs

    Each connector is provided with locking pegs or screws that fasten thecable connector securely to the subrack.

    The connector's locking pegs are placed in the same positions in eachsubrack type, regardless of the subrack's position in a given cabinet. Ifthe subrack includes supplementary locking pegs, they can be used asspare parts.

    1

    2

    3

    4

    5

    12345678910111213141516171819

    XXX

    X

    XXXXX

    XXX

    XXXXXX

    XXXXX

    XXXXX

    XXXXX

    XX

    X

    X

    X

    XXXXX

    XXXXX

    XXXX

    XXXXX

    XXXXX

    XXXXX

    X XX

    X   XXXXX

    X

    XXX X

    XX

    XXX

    XXX

    XX

    X X   X X

    XXXXX

    XXXXX

    XXXXX

    XXXXXXXXXX

    XXXXX

    XXXXX

    XX

    XXXXXXXXXX

    XXXXXXXXXX

    XXXXXXXXXX

    XXXXX

    XXXXX

    XX

    X

    XXXXX

    XXX

    XX

    XXXXX

    XX

     

    Figure 2 Locking pegs’ positions (DN0953997)

    1.3 Categories of cables

    The cabling of an network element consists of interconnection cables(intermediate cables) and site cables (outgoing cables).

    1.3.1 Interconnection cables

    The interconnection cables comprise all the cables inside each cabinetand between the cabinets which form a single network element. Theinterconnection cables are equipped with connectors. They include:

  • 8/9/2019 CableListe_RNC2600_RU40

    9/48

  • 8/9/2019 CableListe_RNC2600_RU40

    10/48

    Cable Lists for RNC2600

    10 (48) © Nokia Siemens Networks DN0938288Issue 02D

    The site cables are not delivered in sets and vary in length depending onthe delivery. They must be ordered separately and are designed foreach delivery.

    1.4 Identifying cables

    The equipping reference is located on the cable identification label (b inFigure Example of marking system for the cables).

    The first part of the equipping reference specifies the cable list where thecable is mentioned. The second part gives the sequence number withinthat list.

    The equipping reference of the cables is based on the cabinet (type)name in which the cable is connected. There are two main groups:

    1. Cables whose both ends are connected in the same cabinet (Intra-cabinet cables).

    The equipping information is expressed: [Cabinet type sequencenumber].”CA_123”. There may be several identical cables of this type ina single Network Element, but only one within the same cabinet.

    2. Cables which originate from one cabinet and end in another (Inter-cabinet cables).

    The equipping information is expressed: [Cabinet type, cabinet index_sequence number].”CBn_123”. There may be only one of eachindividual cable of this type in a single Network Element.

     All Inter-cabinet cables connect from RNBC to RNAC.

    The cabinet, where the cable starts in, determines the [cabinet type,cabinet index] part of the equipping reference.

  • 8/9/2019 CableListe_RNC2600_RU40

    11/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 11 (48) 

    DN99632985

    b) Cable identification label

    ) A letter 'C' after the number indicates centimetres (cm) instead of decimetres (dm).

    Example

    a) Equipping number of cable, e.g.

    Sequential number 

    ITEM NAME:CJA002 LOT ID: 3G9912

     Alias name

    Fixed length (dm)

    Item identifier 

    Separators

    Factory symbol

    Year / Week

    Interchangeability / version

    C19179 .......... A01

    CA-020

    CA_020

    a)

    b)

    CA_020

    a)

     

    Figure 3 Example of the marking system for the cables

  • 8/9/2019 CableListe_RNC2600_RU40

    12/48

    Cable Lists for RNC2600

    12 (48) © Nokia Siemens Networks DN0938288Issue 02D

    1.5 Cabling lists

    The cables are listed in tables. Each cable has its individual number.This number and the address of both ends of the cable are given. Boththe name of the functional unit and connector designation, to which theend of the cable is connected, are given in a table. The columns of thetable are used as follows:

    Table 1 Explanation of cabling list columns

    Equip.No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    Equip.No.

    The equipping number is the individual number of the cable. Both ends of the cable bear a label with this number on it.

    CABLEFROM(RNBC)

    In case of Inter-cabinet cabling, the text CABLE FROM indicates that the cable originates from the RNBC cabinet.

    CABLETO(RNAC)

    In case of Inter-cabinet cabling, the text CABLE TO indicates that the cable ends in the RNAC cabinet.

    Cabinet Cabinet A (RNAC) or cabinet B (RNBC).

    FUThese columns give the name of the functional unit housed in the subrack where the ends of the cable connect to, for exampleMXU.

    Position These columns give the designation of the connectors where the ends of the cable connect to.

    TypeThis column gives the type (the first three or four letters) and length (the following two or three numbers) of the cable indecimeters, or if marked with a C, in centimetres. For example, CHA010 is a cable of CHA type which is 100 cm long.

    Use This column, when used, gives the type of signal carried by the cable, for example PDH line.

    Note This column is for additional information.

    Tip

    The lengths of Intra-cabinet cables in deliveries may be different thanthose given in this document.

  • 8/9/2019 CableListe_RNC2600_RU40

    13/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 13 (48) 

    1.6 Physical cable equipping positions and SW portconnection designation

     This section shows the physical cable equipping positions in the subrackand the corresponding SW port connection designation, used inhardware configuration management.

    The cable connection designations are needed when creating internalport connections between plug-in units' ports. For more information, seeCreating connection descriptions in Hardware ConfigurationManagement in IPA-RNC .

    For example, for a cable installed in position 1.0B 1.4A, the port

    connection coordinate in hardware configuration management (WFcommands) is B76. See also Figure 4 Notations used in table Physicalcable equipping positions and corresponding SW port connectiondesignation.

  • 8/9/2019 CableListe_RNC2600_RU40

    14/48

    Cable Lists for RNC2600

    14 (48) © Nokia Siemens Networks DN0938288Issue 02D

    2A

    C

    E

    G

    J

    L

    N

    P

    R

    T

    V

    X

    Z

    B

    D

    F

    H

    K

    M

    O

    Q

    S

    U

    W

     Y

    3

    B1B2

    ...

    B25

    B76

    1

    2

    3

    4

    5

    4A

    ...

    ...

    B26

    B51

    B101

    1 23

    B76 4A

    DN70206639

    SW HW SW HW SW HW SW HW SW HW

    B1 1A B26 2A B51 3A B76 4A B101 5A

    B2 1B B27 2B B52 3B B77 4B B102 5B

    Slot position number 

    Subrack seen from the rear 

    1

    2

    3

    4

    5

    12345678910111213141516171819

    1

     

    Figure 4 Notations used in table Physical cable equipping positions andcorresponding SW port connection designation 

  • 8/9/2019 CableListe_RNC2600_RU40

    15/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 15 (48) 

    Table 2 Physical cable equipping positions and corresponding SW portconnection designation

    SW HW SW HW SW HW SW HW SW HW

    B1 1A B26 2A B51 3A B76 4A B101 5A

    B2 1B B27 2B B52 3B B77 4B B102 5B

    B3 1C B28 2C B53 3C B78 4C B103 5C

    B4 1D B29 2D B54 3D B79 4D B104 5D

    B5 1E B30 2E B55 3E B80 4E B105 5E

    B6 1F B31 2F B56 3F B81 4F B106 5F

    B7 1G B32 2G B57 3G B82 4G B107 5G

    B8 1H B33 2H B58 3H B83 4H B108 5H

    B9 1J B34 2J B59 3J B84 4J B109 5J

    B10 1K B35 2K B60 3K B85 4K B110 5K

    B11 1L B36 2L B61 3L B86 4L B111 5L

    B12 1M B37 2M B62 3M B87 4M B112 5M

    B13 1N B38 2N B63 3N B88 4N B113 5N

    B14 1O B39 2O B64 3O B89 4O B114 5O

    B15 1P B40 2P B65 3P B90 4P B115 5P

    B16 1Q B41 2Q B66 3Q B91 4Q B116 5Q

    B17 1R B42 2R B67 3R B92 4R B117 5R

    B18 1S B43 2S B68 3S B93 4S B118 5S

    B19 1T B44 2T B69 3T B94 4T B119 5T

    B20 1U B45 2U B70 3U B95 4U B120 5U

    B21 1V B46 2V B71 3V B96 4V B121 5V

    B22 1W B47 2W B72 3W B97 4W B122 5W

    B23 1X B48 2X B73 3X B98 4X B123 5X

    B24 1Y B49 2Y B74 3Y B99 4Y B124 5Y

    B25 1Z B50 2Z B75 3Z B100 4Z B125 5Z

  • 8/9/2019 CableListe_RNC2600_RU40

    16/48

    Cable Lists for RNC2600

    16 (48) © Nokia Siemens Networks DN0938288Issue 02D

    2 Intra-cabinet cables for the RNACcabinet 

    This chapter details the Intra-cabinet cabling for the RNAC cabinet inRNC2600.

    Single cabinet figures show the RNAC cabinet. Two-cabinet figuresshow the RNAC and RNBC cabinets from left to right, unless otherwiseindicated.

    Tip

    The lengths of Intra-cabinet cables in deliveries may be different fromthose given in this document.

    2.1 RNAC power and fan tray control cables

    Table 3 RNAC CPD120-A power and fan tray control cables

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

  • 8/9/2019 CableListe_RNC2600_RU40

    17/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 17 (48) 

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CA_001 A CPD120 UB2 0.10B P1 A PD30 0 1.0B 10_PP2 CVXB004 Power  – CA_002 A CPD120 UB1 0.0B P1 A PD30 0 1.0B 10_PP1 CVXB004 Power  – 

    CA_003 A CPD120 UB2 0.10B P2 A PD30 1 2.0B 10_PP2 CVXB015 Power  – 

    CA_004 A CPD120 UB1 0.0B P2 A PD30 1 20B 10_PP1 CVXB015 Power  – 

    CA_005 A CPD120 UB2 0.10B P3 A PD30 2 3.0B 10_PP2 CVXB020 Power  – 

    CA_006 A CPD120 UB1 0.0B P3 A PD30 2 3.0B 10_PP1 CVXB020 Power  – 

    CA_007 A CPD120 UB2 0.10B P4 A PD30 3 4.0B 10_PP2 CVXB027 Power  – 

    CA_008 A CPD120 UB1 0.0B P4 A PD30 3 4.0B 10_PP1 CVXB027 Power  – 

    CA_010 A FTRA 1 1.0B A PD30 0 1.0B 10_P1 CXVB18C Control  – 

    CA_011 A FTRA 2 2.0B A PD30 1 2.0B 10_P1 CXVB18C Control  – 

    CA_012 A FTRA 3 3.0B A PD30 2 3.0B 10_P1 CXVB18C Control  – 

    CA_013 A FTRA 4 4.0B A PD30 3 4.0B 10_P1 CXVB18C Control  – 

    2.2 RNAC HMS and timing bus cables

    The RNAC timing bus cable configuration shown on the table follows the“star” topology. For information on the “daisy chain” topology, see CableLists for RNC450 .

    Table 4 RNAC HMS and timing bus cables

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

  • 8/9/2019 CableListe_RNC2600_RU40

    18/48

  • 8/9/2019 CableListe_RNC2600_RU40

    19/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 19 (48) 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

    38

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

    38

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

    38

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

    38

    DN05159607

    Terminating cables.

    Be carefully:Do not bend theseshort cables.

     

    Figure 5 HMS bus cables

  • 8/9/2019 CableListe_RNC2600_RU40

    20/48

    Cable Lists for RNC2600

    20 (48) © Nokia Siemens Networks DN0938288Issue 02D

    Figure 6 Routing of timing cables in RNAC

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    DN05159591 

    Timing bus 0 Timing bus 1 

    Terminating cables.

    Be carefully: Do not bend theseshort cables. 

  • 8/9/2019 CableListe_RNC2600_RU40

    21/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 21 (48) 

    Table 5 RNAC default line timing cables

    Equip.No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CA_060 A NPS1/NPS1P 2 3.0B 16.4V A TBU 0 1.0B 19.2G CHZ028 TIMING ref. 1 1) Default linetiming

    CA_061 A NPS1/NPS1P 3 4.0B 16.4V A TBU 0 1.0B 19.2H CHZ028 TIMING ref. 2 1) Default linetiming

    CA_062 A NPS1/NPS1P 4 3.0B 18.4V A TBU 0 1.0B 19.2J CHZ028 TIMING ref. 3 1) Default linetiming

    CA_067 A NPS1/NPS1P 2 3.0B 16.4X A TBU 1 2.0B 38.5G CHZ028 TIMING ref. 1 1) Default linetiming

    CA_068 A NPS1/NPS1P 3 4.0B 16.4X A TBU 1 2.0B 38.5H CHZ028 TIMING ref. 2 1) Default line

    timing

    CA_069 A NPS1/NPS1P 4 3.0B 18.4X A TBU 1 2.0B 38.5J CHZ028 TIMING ref. 3 1) Default linetiming

    1) These cables must be installed last. They are bundled separately from other cables for easier modification.

  • 8/9/2019 CableListe_RNC2600_RU40

    22/48

    Cable Lists for RNC2600

    22 (48) © Nokia Siemens Networks DN0938288Issue 02D

    Figure 7 Routing of line timing cables

  • 8/9/2019 CableListe_RNC2600_RU40

    23/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 23 (48) 

    2.3 RNAC synchronization and LVDS cables

    Table 6 RNAC SFU LVDS cables

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CA_200 A SFU 0 /BISFD

    1.0B 1.B00 A MXU 0 /BISFB

    1.0B 9.B00 CSB007 LVDS lines 3)

    CA_201 A SFU 0 /BISFD

    1.0B 1.B01 A MXU 1 /BISFB

    1.0B 11.B00 CSB009 LVDS lines 3)

    CA_202 A SFU 0 /BISFD

    1.0B 1.B02 A MXU 2 /BISFB

    2.0B 9.B00 CSB012 LVDS lines 3)

    CA_203 A SFU 0 /BISFD

    1.0B 1.B03 A MXU 3 /BISFB

    2.0B 11.B00 CSB013 LVDS lines 3)

    CA_204 A SFU 0 /

    BISFD

    1.0B 1.B04 A MXU 4 /

    BISFB

    3.0B 9.B00 CSB017 LVDS lines 3)

    CA_205 A SFU 0 /BISFD

    1.0B 1.B05 A MXU 5 /BISFB

    3.0B 11.B00 CSB018 LVDS lines 3)

    CA_206 A SFU 0 /BISFD

    1.0B 1.B06 A MXU 6 /BISFB

    4.0B 9.B00 CSB022 LVDS lines 3)

    CA_207 A SFU 0 /BISFD

    1.0B 1.B07 A MXU 7 /BISFB

    4.0B 11.B00 CSB023 LVDS lines 3)

    CA_210 A SFU 0 /BISFA

    1.0B 2.B16 A NPGE/NPGEP 0 /NPS1/NPS1P 0

    1.0B 17.B00 CSB009 LVDS lines 3)

    CA_211 A SFU 0 /BISFA

    1.0B 2.B17 A NPGE/NPGEP 1 /NPS1/NPS1P 1

    2.0B 17.B00 CSB014 LVDS lines 3)

    CA_216 A SFU 0 /BISFA

    1.0B 2.B18 A NPGE/NPGEP 2 1.0B 18.B00 CSB009 LVDS lines 1) 3) Default:connected

    CA_217 A SFU 0 /BISFA

    1.0B 2.B19 A NPGE/NPGEP 3 2.0B 18.B00 CSB014 LVDS lines 2) 3) Default:connected

    CA_212 A SFU 0 /BISFA

    1.0B 2.B20 A NPGE/NPGEP 4 /NPS1/NPS1P 2

    3.0B 15.B00 CSB019 LVDS lines 3)

    CA_213 A SFU 0 /BISFA

    1.0B 2.B21 A NPGE/NPGEP 5 /NPS1/NPS1P 3

    4.0B 15.B00 CSB025 LVDS lines 3)

    CA_214 A SFU 0 /BISFA

    1.0B 2.B22 A NPGE/NPGEP 6 /NPS1/NPS1P 4

    3.0B 17.B00 CSB019 LVDS lines 3)

    CA_215 A SFU 0 /BISFA

    1.0B 2.B23 A NPGE/NPGEP 7 /NPS1/NPS1P 5

    4.0B 17.B00 CSB025 LVDS lines 3)

    CA_220 A SFU 1 /BISFD

    2.0B 1.B00 A MXU 0 /BISFB

    1.0B 9.B02 CSB012 LVDS lines 3)

    CA_221 A SFU 1 /

    BISFD

    2.0B 1.B01 A MXU 1 /

    BISFB

    1.0B 11.B02 CSB013 LVDS lines 3)

    CA_222 A SFU 1 /BISFD

    2.0B 1.B02 A MXU 2 /BISFB

    2.0B 9.B02 CSB007 LVDS lines 3)

    CA_223 A SFU 1 /BISFD

    2.0B 1.B03 A MXU 3 /BISFB

    2.0B 11.B02 CSB008 LVDS lines 3)

    CA_224 A SFU 1 /BISFD

    2.0B 1.B04 A MXU 4 /BISFB

    3.0B 9.B02 CSB012 LVDS lines 3)

    CA_225 A SFU 1 /BISFD

    2.0B 1.B05 A MXU 5 /BISFB

    3.0B 11.B02 CSB013 LVDS lines 3)

    CA_226 A SFU 1 /BISFD

    2.0B 1.B06 A MXU 6 /BISFB

    4.0B 9.B02 CSB017 LVDS lines 3)

  • 8/9/2019 CableListe_RNC2600_RU40

    24/48

    Cable Lists for RNC2600

    24 (48) © Nokia Siemens Networks DN0938288Issue 02D

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CA_227 A SFU 1 /BISFD

    2.0B 1.B07 A MXU 7 /BISFB

    4.0B 11.B02 CSB018 LVDS lines 3)

    CA_230 A SFU 1 /BISFA

    2.0B 2.B16 A NPGE/NPGEP 0 /NPS1/NPS1P 0

    1.0B 17.B02 CSB014 LVDS lines 3)

    CA_231 A SFU 1 /BISFA

    2.0B 2.B17 A NPGE/NPGEP 1 /NPS1/NPS1P 1

    2.0B 17.B02 CSB008 LVDS lines 3)

    CA_236 A SFU 1 /BISFA

    2.0B 2.B18 A NPGE/NPGEP 2 1.0B 18.B02 CSB015 LVDS lines 1) 3) Default:connected

    CA_237 A SFU 1 /BISFA

    2.0B 2.B19 A NPGE/NPGEP 3 2.0B 18.B02 CSB008 LVDS lines 2) 3) Default:connected

    CA_232 A SFU 1 /BISFA

    2.0B 2.B20 A NPGE/NPGEP 4 /NPS1/NPS1P 2

    3.0B 15.B02 CSB014 LVDS lines 3)

    CA_233 A SFU 1 /BISFA

    2.0B 2.B21 A NPGE/NPGEP 5 /NPS1/NPS1P 3

    4.0B 15.B02 CSB019 LVDS lines 3)

    CA_234 A SFU 1 /BISFA

    2.0B 2.B22 A NPGE/NPGEP 6 /NPS1/NPS1P 4

    3.0B 17.B02 CSB014 LVDS lines 3)

    CA_235 A SFU 1 /BISFA

    2.0B 2.B23 A NPGE/NPGEP 7 /NPS1/NPS1P 5

    4.0B 17.B02 CSB019 LVDS lines 3)

    1) Default: connected when NPGE/NPGEP 2 is in configuration.

    Optional: removed when NPS1/NPS1P 0 is in configuration.

    2) Default: connected when NPGE/NPGEP 3 is in configuration.

    Optional: removed when NPS1/NPS1P 1 is in configuration.

    3) Cables connected after panels BISFA, BISFB, BISFC and BISFD have been installed. Insert the back interface unit carefully, It is

    important to check that the locking screws are closed properly, and that the back interface unit is well in its place

    Table 7 TSS3 synchronization cable

    Equip.No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CA_305 A TSS3 1.0B 19.1X A TSS3 2.0B 38.4X CHE011 Sync

  • 8/9/2019 CableListe_RNC2600_RU40

    25/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 25 (48) 

    2.4 RNAC LAN cables

    Table 8 RNAC SWU (ESA40) LAN cables with one SWU pair (SWU0/1)

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CA_131 A SWU 0 1.0B 5.4E A OMU 1 2.0B 16.3B CHES013 LAN  – 

    CA_130 A SWU 0 1.0B 5.4C A OMU 0 1.0B 16.3B CHES006 LAN  – 

    CA_145 A SWU 0 1.0B 5.5D A NPGE/NPGEP 7 /

    NPS1/NPS1P 5

    4.0B 17.4E CIBS027 LAN  – 

    CA_144 A SWU 0 1.0B 5.5B A NPGE/NPGEP 6 /NPS1/NPS1P 4

    3.0B 17.4E CIBS021 LAN  – 

    CA_143 A SWU 0 1.0B 5.4Z A NPGE/NPGEP 5 /

    NPS1/NPS1P 3

    4.0B 15.4E CIBS027 LAN  – 

    CA_172 A SWU 0 1.0B 5.4X A NPGE/NPGEP 4 /

    NPS1/NPS1P 2

    3.0B 15.4E CIBS021 LAN  – 

    CA_147 A SWU 0 1.0B 5.4V A NPGE/NPGEP 3 2.0B 18.4E CIBS013 LAN 2) Default:connected

    CA_146 A SWU 0 1.0B 5.4T A NPGE/NPGEP 2 1.0B 18.4E CIBS007 LAN 1) Default:connected

    CA_171 A SWU 0 1.0B 5.4R A NPGE/NPGEP 1 /

    NPS1/NPS1P 1

    2.0B 17.4E CIBS013 LAN  – 

    CA_140 A SWU 0 1.0B 5.4P A NPGE/NPGEP 0 /

    NPS1/NPS1P 0

    1.0B 17.4E CIBS007 LAN  – 

    CA_134 A SWU 1 2.0B 5.4J A SWU 0 1.0B 5.4J CHES017 LAN 3) Default:Notconnected

    CA_139 A SWU 1 2.0B 5.4E A OMU 1 2.0B 16.3D CHES007 LAN  – 

    CA_138 A SWU 1 2.0B 5.4C A OMU 0 1.0B 16.3D CHES014 LAN  – 

    CA_155 A SWU 1 2.0B 5.5D A NPGE/NPGEP 7 /

    NPS1/NPS1P 5

    4.0B 17.4G CIBS021 LAN  – 

    CA_154 A SWU 1 2.0B 5.5B A NPGE/NPGEP 6 /

    NPS1/NPS1P 4

    3.0B 17.4G CIBS021 LAN  – 

    CA_153 A SWU 1 2.0B 5.4Z A NPGE/NPGEP 5 /

    NPS1/NPS1P 3

    4.0B 15.4G CIBS021 LAN  – 

    CA_152 A SWU 1 2.0B 5.4X A NPGE/NPGEP 4 /NPS1/NPS1P 2 3.0B 15.4G CIBS014 LAN  – 

    CA_149 A SWU 1 2.0B 5.4V A NPGE/NPGEP 3 2.0B 18.4G CIBS007 LAN 2) Default:connected

    CA_148 A SWU 1 2.0B 5.4T A NPGE/NPGEP 2 1.0B 18.4G CIBS013 LAN 1) Default:connected

    CA_151 A SWU 1 2.0B 5.4R A NPGE/NPGEP 1 /

    NPS1/NPS1P 1

    2.0B 17.4G CIBS007 LAN  – 

    CA_150 A SWU 1 2.0B 5.4P A NPGE/NPGEP 0 /

    NPS1/NPS1P 0

    1.0B 17.4G CIBS013 LAN  – 

  • 8/9/2019 CableListe_RNC2600_RU40

    26/48

  • 8/9/2019 CableListe_RNC2600_RU40

    27/48

  • 8/9/2019 CableListe_RNC2600_RU40

    28/48

    Cable Lists for RNC2600

    28 (48) © Nokia Siemens Networks DN0938288Issue 02D

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

    38

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

    38

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

    38

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

    38

    CPSY-A

    CPAL-A

    CPSY-B

    DN05160803 

    Figure 8 CPSY-A, CPSY-B and CPAL-A panel positions in RNAC

  • 8/9/2019 CableListe_RNC2600_RU40

    29/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 29 (48) 

    2.6 RNAC protection switch cables

    Table 11 MSP1+1, PIU_OK, PAIR_OK and switchover cables for RNAC

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CA_370 A NPS1P 0 1.0B 18.4T A NPS1P 1 2.0B 18.4T CIBS010 MSP1+1ProtectionSwitch

    1) Default:not connected

    CA_375 A NPS1P 0 1.0B 18.4R A NPS1P 1 2.0B 18.4R CIBS010 LVDS linesProtectionSwitch

    1) Default:not connected

    CA_374 A NPS1P 0 1.0B 18.4P A NPS1P 1 2.0B 18.4P CIBS010 LVDS linesProtection

    Switch

    1) Default:not connected

    CA_165 A NPGEP 2 1.0B 18.4L A NPGEP 3 2.0B 18.4L CHZS010 Switchover  – 

    CA_373 A NPS1P 0 1.0B 18.4J A NPS1P 1 2.0B 18.4J CIBS010 MSP1+1ProtectionSwitch

     – 

    NPGEP 2 NPGEP 3 PIU_OK/PAIR_OK

    CA_372 A NPS1P 0 1.0B 18.4G A NPS1P 1 2.0B 18.4G CIBS010 MSP1+1ProtectionSwitch

    1) Default:not connected

    CA_371 A NPS1P 0 1.0B 18.4E A NPS1P 1 2.0B 18.4E CIBS010 MSP1+1ProtectionSwitch

    1) Default:not connected

    CA_163 A NPGEP 0 /

    NPS1P 0

    1.0B 17.4L A NPGEP 1 /

    NPS1P 1

    2.0B 17.4L CHZS010 Switchover  – 

    CA_164 A NPGEP 0 /

    NPS1P 0

    1.0B 17.4K A NPGEP 1 /

    NPS1P 1

    2.0B 17.4K CHZS010 PIU_OK/PAIR_OK

     – 

    CA_358 A NPS1P 2 3.0B 16.4T A NPS1P 3 4.0B 16.4T CIBS010 MSP1+1ProtectionSwitch

     – 

    CA_361 A NPS1P 2 3.0B 16.4R A NPS1P 3 4.0B 16.4R CIBS010 LVDS linesProtectionSwitch

     – 

    CA_360 A NPS1P 2 3.0B 16.4P A NPS1P 3 4.0B 16.4P CIBS010 LVDS linesProtectionSwitch

     – 

    CA_351 A NPS1P 2 3.0B 16.4J A NPS1P 3 4.0B 16.4J CIBS010 MSP1+1

    ProtectionSwitch

     – 

    CA_359 A NPS1P 2 3.0B 16.4G A NPS1P 3 4.0B 16.4G CIBS010 MSP1+1ProtectionSwitch

     – 

    CA_350 A NPS1P 2 3.0B 16.4E A NPS1P 3 4.0B 16.4E CIBS010 MSP1+1ProtectionSwitch

     – 

    CA_161 A NPGEP 4 /

    NPS1P 2

    3.0B 15.4L A NPGEP 5 /

    NPS1P 3

    4.0B 15.4L CHZS010 Switchover  – 

    CA_162 A NPGEP 4 /

    NPS1P 2

    3.0B 15.4K A NPGEP 5 /

    NPS1P 3

    4.0B 15.4K CHZS010 PIU_OK/PAIR_OK

     – 

  • 8/9/2019 CableListe_RNC2600_RU40

    30/48

    Cable Lists for RNC2600

    30 (48) © Nokia Siemens Networks DN0938288Issue 02D

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CA_354 A NPS1P 4 3.0B 18.4T A NPS1P 5 4.0B 18.4T CIBS010 MSP1+1ProtectionSwitch

     – 

    CA_357 A NPS1P 4 3.0B 18.4R A NPS1P 5 4.0B 18.4R CIBS010 LVDS linesProtectionSwitch

     – 

    CA_356 A NPS1P 4 3.0B 18.4P A NPS1P 5 4.0B 18.4P CIBS010 LVDS linesProtectionSwitch

     – 

    CA_353 A NPS1P 4 3.0B 18.4J A NPS1P 5 4.0B 18.4J CIBS010 MSP1+1ProtectionSwitch

     – 

    CA_355 A NPS1P 4 3.0B 18.4G A NPS1P 5 4.0B 18.4G CIBS010 MSP1+1Protection

    Switch

     – 

    CA_352 A NPS1P 4 3.0B 18.4E A NPS1P 5 4.0B 18.4E CIBS010 MSP1+1ProtectionSwitch

     – 

    CA_156 A NPGEP 6 /

    NPS1P 4

    3.0B 17.4L A NPGEP 7 /

    NPS1P 5

    4.0B 17.4L CHZS010 Switchover  – 

    CA_157 A NPGEP 6 /

    NPS1P 4

    3.0B 17.4K A NPGEP 7 /

    NPS1P 5

    4.0B 17.4K CHZS010 PIU_OK/PAIR_OK

     – 

    1) Default: Not connected at the factory. Cable is tied to the SRBI-C side plate near these equipping positions. Optional: Cables areconnected these equipping positions when NPS1P 0 and NPS1P 1 pair are equipped.

    2.7 RNAC PCIe and Mini SAS cables

    Table 12 RNAC PCIe and Mini SAS cables

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

  • 8/9/2019 CableListe_RNC2600_RU40

    31/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 31 (48) 

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CA_075 A OMU 0 1.0F 16.PCIe1 A WDU 0 (OMU) 1.0F 14.PCIe CQSFP25C PCIe  – CA_076 A OMU 1 2.0F 16.PCIe1 A WDU 1 (OMU) 2.0F 14.PCIe CQSFP25C PCIe  – 

    CA_077 A WDU 0 (OMU) 1.0F 14.SAS A WDU 1 (OMU) 2.0F 14.SAS CMSAS011  SAS  – 

    2.8 L3 Data Collector Cables for RNAC cabinet

    Table 13 L3 Data Collector Cables for RNAC cabinet

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CA_250 A ICSU 0 1.0B 03.3B A CPLAN-A Port 4 CHUS014 LAN EL0  – 

    CA_251 A RSMU 0 1.0B 04.3B A CPLAN-A Port 2 CHUS014 LAN EL0  – 

    CA_252 A OMU 0 1.0B 16.3B A CPLAN-A Port 0 CHUS016 LAN EL1 Optional

    CA_253 A ICSU 1 2.0B 03.3B A CPLAN-A Port 5 CHUS021 LAN EL0  – 

    CA_254 A RSMU 1 2.0B 04.3B A CPLAN-A Port 3 CHUS021 LAN EL0  – 

    CA_255 A ICSU 2 2.0B 06.3B A CPLAN-A Port 6 CHUS021 LAN EL0  – 

    CA_256 A OMU 1 2.0B 16.3B A CPLAN-A Port 1 CHUS020 LAN EL1 Optional

    CA_257 A ICSU 3 3.0B 01.3B A CPLAN-A Port 7 CHUS024 LAN EL0  – 

    CA_258 A ICSU 4 3.0B 02.3B A CPLAN-A Port 8 CHUS024 LAN EL0  – 

    CA_259 A ICSU 5 3.0B 03.3B A CPLAN-A Port 9 CHUS024 LAN EL0  – 

    CA_260 A ICSU 6 3.0B 04.3B A CPLAN-A Port 10 CHUS024 LAN EL0  – 

    CA_261 A ICSU 7 3.0B 14.3B A CPLAN-A Port 11 CHUS025 LAN EL0  – 

    CA_262 A ICSU 8 4.0B 01.3B A CPLAN-A Port 12 CHUS025 LAN EL0  – 

    CA_263 A ICSU 9 4.0B 02.3B A CPLAN-A Port 13 CHUS026 LAN EL0  – 

    CA_264 A ICSU 10 4.0B 03.3B A CPLAN-A Port 14 CHUS026 LAN EL0  – 

    CA_265 A ICSU 11 4.0B 04.3B A CPLAN-A Port 15 CHUS026 LAN EL0  – 

    CA_266 A ICSU 12 4.0B 05.3B A CPLAN-A Port 16 CHUS026 LAN EL0  – 

    CA_267 A ICSU 13 4.0B 14.3B A CPLAN-A Port 17 CHUS027 LAN EL0  – 

  • 8/9/2019 CableListe_RNC2600_RU40

    32/48

    Cable Lists for RNC2600

    32 (48) © Nokia Siemens Networks DN0938288Issue 02D

    3 Intra-cabinet cables for the RNBCcabinet 

    This chapter presents the Intra-cabinet cabling for the RNBC cabinet inRNC2600.

    Tip

    The lengths of Intra-cabinet cables in deliveries may be different thanthose given in this document.

    3.1 RNBC power and fan tray control cables

    Table 14 RNBC CPD120-A power cables and fan tray control cables

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB_001 B CPD120 UB2 0.10B P1 B PD30 0 1.0B 10_PP2 CVXB004 Power  – 

    CB_002 B CPD120 UB1 0.0B P1 B PD30 0 1.0B 10_PP1 CVXB004 Power  – 

    CB_003 B CPD120 UB2 0.10B P2 B PD30 1 2.0B 10_PP2 CVXB015 Power  – 

    CB_004 B CPD120 UB1 0.0B P2 B PD30 1 2.0B 10_PP1 CVXB015 Power  – 

    CB_005 B CPD120 UB2 0.10B P3 B PD30 2 3.0B 10_PP2 CVXB020 Power  – 

    CB_006 B CPD120 UB1 0.0B P3 B PD30 2 3.0B 10_PP1 CVXB020 Power  – 

    CB_007 B CPD120 UB2 0.10B P4 B PD30 3 4.0B 10_PP2 CVXB027 Power  – 

    CB_008 B CPD120 UB1 0.0B P4 B PD30 3 4.0B 10_PP1 CVXB027 Power  – 

    CB_010 B FTRA 1 1.0B B PD30 0 1.0B 10_P1 CXVB18C Control  – 

    CB_011 B FTRA 2 2.0B B PD30 1 2.0B 10_P1 CXVB18C Control  – 

  • 8/9/2019 CableListe_RNC2600_RU40

    33/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 33 (48) 

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB_012 B FTRA 3 3.0B B PD30 2 3.0B 10_P1 CXVB18C Control  – 

    CB_013 B FTRA 4 4.0B B PD30 3 4.0B 10_P1 CXVB18C Control  – 

    3.2 RNBC HMS bus and timing bus cables

    The RNBC timing bus cable configuration shown on the table follows the“star” topology. For information on the “daisy chain” topology, see CableLists for RNC450  

    Table 15 RNBC HMS and timing bus cables

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB_020 B TBU 0 1.0B 19.2B B TBU 0 2.0B 19.2A CHZ011 HMS bus 0  – 

    CB_021 B TBU 0 2.0B 19.2B B TBU 0 3.0B 19.2A CHZ011 HMS bus 0  – 

    CB_022 B TBU 0 3.0B 19.2B B TBU 0 4.0B 19.2A CHZ011 HMS bus 0  – 

    CB_023 B TBU 0 4.0B 19.2C B TBU 0 4.0B 19.2D CHZ001 HMS bus 0

    term

     – 

    CB_024 B TBU 1 1.0B 38.5B B TBU 1 2.0B 38.5A CHZ009 HMS bus 1  – 

    CB_025 B TBU 1 2.0B 38.5B B TBU 1 3.0B 38.5A CHZ009 HMS bus 1  – 

    CB_026 B TBU 1 3.0B 38.5B B TBU 1 4.0B 38.5A CHZ009 HMS bus 1  – 

    CB_027 B TBU 1 4.0B 38.5C B TBU 1 4.0B 38.5D CHZ001 HMS bus 1term

     – 

    CB_030 B TBU 0 1.0B 19.2L B TBU 0 1.0B 19.2E CHZ001 TIMING bus 0

    term.

     – 

    CB_031 B TBU 0 2.0B 19.2L B TBU 0 2.0B 19.2E CHZ001 TIMING bus 0

    term.

     – 

    CB_032 B TBU 0 3.0B 19.2L B TBU 0 3.0B 19.2E CHZ001 TIMING bus 0

    term.

     – 

    CB_033 B TBU 0 4.0B 19.2L B TBU 0 4.0B 19.2E CHZ001 TIMING bus 0term

     – 

    CB_034 B TBU 1 1.0B 38.5L B TBU 1 1.0B 38.5E CHZ001 TIMING bus 1term.

     – 

  • 8/9/2019 CableListe_RNC2600_RU40

    34/48

    Cable Lists for RNC2600

    34 (48) © Nokia Siemens Networks DN0938288Issue 02D

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB_035 B TBU 1 2.0B 38.5L B TBU 1 2.0B 38.5E CHZ001 TIMING bus 1term.

     – 

    CB_036 B TBU 1 3.0B 38.5L B TBU 1 3.0B 38.5E CHZ001 TIMING bus 1term.

     – 

    CB_037 B TBU 1 4.0B 38.5L B TBU 1 4.0B 38.5E CHZ001 TIMING bus 1term.

     – 

  • 8/9/2019 CableListe_RNC2600_RU40

    35/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 35 (48) 

    Figure 9 Routing of timing cables in RNBC

  • 8/9/2019 CableListe_RNC2600_RU40

    36/48

    Cable Lists for RNC2600

    36 (48) © Nokia Siemens Networks DN0938288Issue 02D

    3.3 RNBC protection switch cables

    Table 16 RNBC protection switch cables

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB_354 B NPS1P 6 1.0B 16.4T B NPS1P 7 2.0B 16.4T CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_371 B NPS1P 6 1.0B 16.4E B NPS1P 7 2.0B 16.4E CIBS013 LVDS linesProtectionSwitch

     – 

    CB_370 B NPS1P 6 1.0B 16.4J B NPS1P 7 2.0B 16.4J CIBS013 LVDS linesProtectionSwitch

     – 

    CB_357 B NPS1P 6 1.0B 16.4R B NPS1P 7 2.0B 16.4R CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_356 B NPS1P 6 1.0B 16.4P B NPS1P 7 2.0B 16.4P CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_355 B NPS1P 6 1.0B 16.4G B NPS1P 7 2.0B 16.4G CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_358 B NPS1P 8 1.0B 18.4T B NPS1P 9 2.0B 18.4T CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_373 B NPS1P 8 1.0B 18.4E B NPS1P 9 2.0B 18.4E CIBS013 LVDS linesProtectionSwitch

     – 

    CB_372 B NPS1P 8 1.0B 18.4J B NPS1P 9 2.0B 18.4J CIBS013 LVDS linesProtectionSwitch

     – 

    CB_361 B NPS1P 8 1.0B 18.4R B NPS1P 9 2.0B 18.4R CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_360 B NPS1P 8 1.0B 18.4P B NPS1P 9 2.0B 18.4P CIBS013 MSP1+1Protection

    Switch

     – 

    CB_359 B NPS1P 8 1.0B 18.4G B NPS1P 9 2.0B 18.4G CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_362 B NPS1P 10 3.0B 16.4T B NPS1P 11 4.0B 16.4T CIBS013 MSP1+1ProtectionSwitch

     – 

  • 8/9/2019 CableListe_RNC2600_RU40

    37/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 37 (48) 

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB_375 B NPS1P 10 3.0B 16.4E B NPS1P 11 4.0B 16.4E CIBS013 LVDS linesProtectionSwitch

     – 

    CB_374 B NPS1P 10 3.0B 16.4J B NPS1P 11 4.0B 16.4J CIBS013 LVDS linesProtectionSwitch

     – 

    CB_365 B NPS1P 10 3.0B 16.4R B NPS1P 11 4.0B 16.4R CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_364 B NPS1P 10 3.0B 16.4P B NPS1P 11 4.0B 16.4P CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_363 B NPS1P 10 3.0B 16.4G B NPS1P 11 4.0B 16.4G CIBS013 MSP1+1Protection

    Switch

     – 

    CB_366 B NPS1P 12 3.0B 18.4T B NPS1P 13 4.0B 18.4T CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_377 B NPS1P 12 3.0B 18.4E B NPS1P 13 4.0B 18.4E CIBS013 LVDS linesProtectionSwitch

     – 

    CB_376 B NPS1P 12 3.0B 18.4J B NPS1P 13 4.0B 18.4J CIBS013 LVDS linesProtectionSwitch

     – 

    CB_369 B NPS1P 12 3.0B 18.4R B NPS1P 13 4.0B 18.4R CIBS013 MSP1+1Protection

    Switch

     – 

    CB_368 B NPS1P 12 3.0B 18.4P B NPS1P 13 4.0B 18.4P CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_367 B NPS1P 12 3.0B 18.4G B NPS1P 13 4.0B 18.4G CIBS013 MSP1+1ProtectionSwitch

     – 

    CB_380 B NPGEP 8 /

    NPS1P 6

    1.0B 15.4K B NPGEP 9 /

    NPS1P 7

    2.0B 15.4K CHZS015 PIU_OK

    PAIR_OK

     – 

    CB_381 B NPGEP 10 /

    NPS1P 8

    1.0B 17.4K B NPGEP 11 /

    NPS1P 9

    2.0B 17.4K CHZS015 PIU_OK

    PAIR_OK

     – 

    CB_382 B NPGEP 12 /

    NPS1P 10

    3.0B 15.4K B NPGEP 13 /

    NPS1P 11

    4.0B 15.4K CHZS015 PIU_OK

    PAIR_OK

     – 

    CB_383 B NPGEP 14 /

    NPS1P 12

    3.0B 17.4K B NPGEP 15 /

    NPS1P 13

    4.0B 17.4K CHZS015 PIU_OK

    PAIR_OK

     – 

    CB_390 B NPGEP 8 /

    NPS1P 6

    1.0B 15.4L B NPGEP 9 /

    NPS1P 7

    2.0B 15.4L CHZS015 Switchover – 

  • 8/9/2019 CableListe_RNC2600_RU40

    38/48

    Cable Lists for RNC2600

    38 (48) © Nokia Siemens Networks DN0938288Issue 02D

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB_391 B NPGEP 10 /

    NPS1P 8

    1.0B 17.4L B NPGEP 11 /

    NPS1P 9

    2.0B 17.4L CHZS015 Switchover  – 

    CB_392 B NPGEP 12 /

    NPS1P 10

    3.0B 15.4L B NPGEP 13 /

    NPS1P 11

    4.0B 15.4L CHZS015 Switchover  – 

    CB_393 B NPGEP 14 /

    NPS1P 12

    3.0B 17.4L B NPGEP 15 /

    NPS1P 13

    4.0B 17.4L CHZS015 Switchover  – 

    3.4 L3 Data Collector Cables for RNBC cabinet

    Table 17 L3 Data Collector Cables for RNBC cabinet

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB_250 B ICSU 14 1.0B 01.3B B CPLAN-A Port 0 CHUS016 LAN EL0  – 

    CB_251 B ICSU 15 1.0B 02.3B B CPLAN-A Port 1 CHUS016 LAN EL0  – 

    CB_252 B ICSU 16 1.0B 03.3B B CPLAN-A Port 2 CHUS016 LAN EL0  – 

    CB_253 B ICSU 17 1.0B 04.3B B CPLAN-A Port 3 CHUS016 LAN EL0  – 

    CB_254 B ICSU 18 1.0B 05.3B B CPLAN-A Port 4 CHUS016 LAN EL0  – 

    CB_255 B ICSU 19 1.0B 14.3B B CPLAN-A Port 5 CHUS018 LAN EL0  – 

    CB_256 B ICSU 20 2.0B 01.3B B CPLAN-A Port 6 CHUS018 LAN EL0  – 

    CB_257 B ICSU 21 2.0B 02.3B B CPLAN-A Port 7 CHUS018 LAN EL0  – 

    CB_258 B ICSU 22 2.0B 03.3B B CPLAN-A Port 8 CHUS018 LAN EL0  – 

    CB_259 B ICSU 23 2.0B 4.3B B CPLAN-A Port 9 CHUS018 LAN EL0  – 

    CB_260 B ICSU 24 2.0B 05.3B B CPLAN-A Port 10 CHUS018 LAN EL0  – 

    CB_261 B ICSU 25 2.0B 14.3B B CPLAN-A Port 11 CHUS020 LAN EL0  – 

    CB_262 B ICSU 26 3.0B 01.3B B CPLAN-A Port 12 CHUS021 LAN EL0  – 

    CB_263 B ICSU 27 3.0B 02.3B B CPLAN-A Port 13 CHUS021 LAN EL0  – 

    CB_264 B ICSU 28 3.0B 03.3B B CPLAN-A Port 14 CHUS021 LAN EL0  – 

    CB_265 B ICSU 29 3.0B 04.3B B CPLAN-A Port 15 CHUS021 LAN EL0  – 

    CB_266 B ICSU 30 3.0B 05.3B B CPLAN-A Port 16 CHUS021 LAN EL0  – 

  • 8/9/2019 CableListe_RNC2600_RU40

    39/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 39 (48) 

    Equip.

    No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB_267 B ICSU 31 3.0B 14.3B B CPLAN-A Port 17 CHUS024 LAN EL0  – 

    CB_268 B ICSU 32 4.0B 01.3B B CPLAN-A Port 18 CHUS026 LAN EL0  – 

    CB_269 B ICSU 33 4.0B 02.3B B CPLAN-A Port 19 CHUS026 LAN EL0  – 

    CB_270 B ICSU 34 4.0B 03.3B B CPLAN-A Port 20 CHUS026 LAN EL0  – 

    CB_271 B ICSU 35 4.0B 04.3B B CPLAN-A Port 21 CHUS026 LAN EL0  – 

    CB_272 B ICSU 36 4.0B 05.3B B CPLAN-A Port 22 CHUS026 LAN EL0  – 

    CB_273 B ICSU 37 4.0B 14.3B B CPLAN-A Port 23 CHUS028 LAN EL0  – 

  • 8/9/2019 CableListe_RNC2600_RU40

    40/48

    Cable Lists for RNC2600

    40 (48) © Nokia Siemens Networks DN0938288Issue 02D

    4 Inter-cabinet cables from RNBC toRNAC 

    This chapter details cabling from the RNBC cabinet to the RNAC cabinetin RNC2600.

    4.1 Inter-cabinet HMS and timing cables

    The timing bus cable configuration shown on the table follows the “star”topology. For information on the “daisy chain” topology, see Cable Listsfor RNC450  

    Table 18 Inter-cabinet HMS and timing cables from RNAC to RNBC

    Equip.No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB0_050  A TBU 0 1.0B 19.2N –   –   – 

    CHZ016 TIMING bus 01)

    B TBU 0 1.0B 19.2K 2)

    CB0_052  A TBU 0 1.0B 19.2O –   –   – 

    CHZ020 TIMING bus 01)

    B TBU 0 2.0B 19.2K 2)

    CB0_054  A TBU 0 1.0B 19.2P

     –   –   – 

    CHZ024 TIMING bus 0

    1)

    B TBU 0 3.0B 19.2K 2)

    CB0_056 A TBU 0 1.0B 19.2Q –   –   – 

    CHZ028 TIMING bus 01)

    B TBU 0 4.0B 19.2K 2)

    CB0_051  A TBU 1 2.0B 38.5N –   –   – 

    CHZ020 TIMING bus 11)

    B TBU 1 1.0B 38.5K 2)

    CB0_053 A TBU 1 2.0B 38.5O –   –   – 

    CHZ016 TIMING bus 11)

    B TBU 1 2.0B 38.5K 2)

  • 8/9/2019 CableListe_RNC2600_RU40

    41/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 41 (48) 

    Equip.No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB0_055 A TBU 1 2.0B 38.5P  –   –   –  CHZ020 TIMING bus 1 1)B TBU 1 3.0B 38.5K 2)

    CB0_057 A TBU 1 2.0B 38.5Q –   –   – 

    CHZ024 TIMING bus 11)

    B TBU 1 4.0B 38.5K 2)

    CB0_040

     A

    TBU 0

    3.0B 19.2D

     A TBU 0 1.0B 19.2C CHZ020 HMS bus 0

    3) HMS term.

    B 1.0B 19.2A 4) HMS to B-cabinet

    CB0_041

     A

    TBU 1

    3.0B 38.5D

     A TBU 1 1.0B 38.5C CHZ020 HMS bus 1

    3) HMS term.

    B 1.0B 38.5A 4) HMS to B-cabinet

    1) Default: Equipped at factory. Cables are bundled together and left unconnected if RNBC cabinet is not in the configuration.

    2) Optional: If RNBC is in configuration these cables are connected to RNBC.

    3) Default: Equipped at factory. Equip these terminating cables to sub rack 3 if RNBC cabinet is not in the configuration.

    4) Optional: If RNBC is in configuration these cables are moved to RNBC subrack 1.

    If the RNC2600 has the old “daisy chain” topology for timing bus cables,see Cable Lists for RNC450 .

    The “daisy chain” cabling is identical for RNC450 and RNC2600, withtwo exceptions:

      Concerning the inter-cabinet cable CB0_050 for Timing bus 0,the cable type for this cable is CHZ015 in RNC450, and CHZ020in RNC2600. Nonetheless, this cable is connected in the samepositions for both RNC450 and RNC2600. The cable type has noeffect to the configuration.

      When the RNBC cabinet is added or removed, whetherexpanding from capacity step 1, to step 2 or step 3; ordowngrading from step 2 or step 3, to step 1, the inter-cabinetcables CB0_050 and CB0_051 for Timing buses 0 and 1 arehandled differently in RNC450 and RNC2600:

    - In RNC450, these two cables come attached to theRNBC expansion cabinet.

    - In RNC2600, these two cables come with the RNACcabinet. In RNC2600, these two cables go as shown onTable 20 Timing cables from RNBC to RNAC: “daisychain”.

  • 8/9/2019 CableListe_RNC2600_RU40

    42/48

  • 8/9/2019 CableListe_RNC2600_RU40

    43/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 43 (48) 

    Figure 10 Routing of HMS cables

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 

    38 

    RNBC RNAC

    DN05160893 

    = HMS bus 0= HMS bus 1 

  • 8/9/2019 CableListe_RNC2600_RU40

    44/48

    Cable Lists for RNC2600

    44 (48) © Nokia Siemens Networks DN0938288Issue 02D

    Black = Timing Bus 0

    Green = Timing Bus 1

    Figure 11 Routing of Inter-cabinet timing cables

  • 8/9/2019 CableListe_RNC2600_RU40

    45/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 45 (48) 

    4.2 Inter-cabinet SWU LAN cables

    Table 20 Inter-cabinet SWU LAN cables

    Equip.No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB0_107 B NPGE/NPGEP 15 /

    NPS1/NPS1P 13

    4.0B 17.4E A SWU 0 1.0B 5.5U CIBS027 LAN 1)

    CB0_106 B NPGE/NPGEP 14 /

    NPS1/NPS1P 12

    3.0B 17.4E A SWU 0 1.0B 5.5S CIBS021 LAN 1)

    CB0_105 B NPGE/NPGEP 13 /

    NPS1/NPS1P 11

    4.0B 15.4E A SWU 0 1.0B 5.5Q CIBS027 LAN 1)

    CB0_104 B NPGE/NPGEP 12 /

    NPS1/NPS1P 10

    3.0B 15.4E A SWU 0 1.0B 5.5O CIBS021 LAN 1)

    CB0_103 B NPGE/NPGEP 11 /

    NPS1/NPS1P 9

    2.0B 17.4E A SWU 0 1.0B 5.5M CIBS018 LAN 1)

    CB0_102 B NPGE/NPGEP 10 /

    NPS1/NPS1P 8

    1.0B 17.4E A SWU 0 1.0B 5.5K CIBS014 LAN 1)

    CB0_101 B NPGE/NPGEP 9 /

    NPS1/NPS1P 7

    2.0B 15.4E A SWU 0 1.0B 5.5H CIBS018 LAN 1)

    CB0_100 B NPGE/NPGEP 8 /

    NPS1/NPS1P 6

    1.0B 15.4E A SWU 0 1.0B 5.5F CIBS014 LAN 1)

    CB0_115 B NPGE/NPGEP 15 /

    NPS1/NPS1P 13

    4.0B 17.4G A SWU 1 2.0B 5.5U CIBS021 LAN 1)

    CB0_114 B NPGE/NPGEP 14 /

    NPS1/NPS1P 12

    3.0B 17.4G A SWU 1 2.0B 5.5S CIBS018 LAN 1)

    CB0_113 B NPGE/NPGEP 13 /

    NPS1/NPS1P 11

    4.0B 15.4G A SWU 1 2.0B 5.5Q CIBS021 LAN 1)

    CB0_112 B NPGE/NPGEP 12 /

    NPS1/NPS1P 10

    3.0B 15.4G A SWU 1 2.0B 5.5O CIBS018 LAN 1)

    CB0_111 B NPGE/NPGEP 11 /

    NPS1/NPS1P 9

    2.0B 17.4G A SWU 1 2.0B 5.5M CIBS014 LAN 1)

    CB0_110 B NPGE/NPGEP 10 /

    NPS1/NPS1P 8

    1.0B 17.4G A SWU 1 2.0B 5.5K CIBS018 LAN 1)

    CB0_109 B NPGE/NPGEP 9 /

    NPS1/NPS1P 7

    2.0B 15.4G A SWU 1 2.0B 5.5H CIBS014 LAN 1)

    CB0_108 B NPGE/NPGEP 8 /

    NPS1/NPS1P 6

    1.0B 15.4G A SWU 1 2.0B 5.5F CIBS018 LAN 1)

    1) Cables are connected before the BISFC back interface unit has been installed.

  • 8/9/2019 CableListe_RNC2600_RU40

    46/48

    Cable Lists for RNC2600

    46 (48) © Nokia Siemens Networks DN0938288Issue 02D

    4.3 Inter-cabinet SFU LVDS lines

    Table 21 Inter-cabinet SFU LVDS cables

    Equip.No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB0_200 B MXU 8 /

    BISFB

    1.0B 9.B00 A SFU 0 /

    BISFA

    1.0B 2.B08 CSB018 LVDS lines 1)

    CB0_201 B MXU 9 /

    BISFB

    1.0B 11.B00 A SFU 0 /

    BISFA

    1.0B 2.B09 CSB021 LVDS lines 1)

    CB0_202 B MXU 10 /

    BISFB

    2.0B 9.B00 A SFU 0 /

    BISFA

    1.0B 2.B10 CSB022 LVDS lines 1)

    CB0_203 B MXU 11 /

    BISFB

    2.0B 11.B00 A SFU 0 /

    BISFA

    1.0B 2.B11 CSB024 LVDS lines 1)

    CB0_204 B MXU 12 /

    BISFB

    3.0B 9.B00 A SFU 0 /

    BISFA

    1.0B 2.B12 CSB028 LVDS lines 1)

    CB0_205 B MXU13 /

    BISFB

    3.0B 11.B00 A SFU 0 /

    BISFA

    1.0B 2.B13 CSB030 LVDS lines 1)

    CB0_206 B MXU 14 /

    BISFB

    4.0B 9.B00 A SFU 0 /

    BISFA

    1.0B 2.B14 CSB032 LVDS lines 1)

    CB0_207 B MXU 15 /

    BISFB

    4.0B 11.B00 A SFU 0 /

    BISFA

    1.0B 2.B15 CSB032 LVDS lines 1)

    CB0_208 B NPGE/NPGEP 8 /

    NPS1/NPS1P 6

    1.0B 15.B00 A SFU 0 /

    BISFA

    1.0B 2.B24 CSB019 LVDS lines 1)

    CB0_209 B NPGE/NPGEP 9 /

    NPS1/NPS1P 7

    2.0B 15.B00 A SFU 0 /

    BISFA

    1.0B 2.B25 CSB025 LVDS lines 1)

    CB0_210 B NPGE/NPGEP 10 /

    NPS1/NPS1P 8

    1.0B 17.B00 A SFU 0 /

    BISFA

    1.0B 2.B26 CSB019 LVDS lines 1)

    CB0_211 B NPGE/NPGEP 11 /

    NPS1/NPS1P 9

    2.0B 17.B00 A SFU 0 /

    BISFA

    1.0B 2.B27 CSB025 LVDS lines 1)

    CB0_212 B NPGE/NPGEP 12 /

    NPS1/NPS1P 10

    3.0B 15.B00 A SFU 0 /

    BISFA

    1.0B 2.B28 CSB031 LVDS lines 1)

    CB0_213 B NPGE/NPGEP 13 /

    NPS1/NPS1P 11

    4.0B 15.B00 A SFU 0 /

    BISFA

    1.0B 2.B29 CSB034 LVDS lines 1)

    CB0_214 B NPGE/NPGEP 14 /

    NPS1/NPS1P 12

    3.0B 17.B00 A SFU 0 /

    BISFA

    1.0B 2.B30 CSB031 LVDS lines 1)

    CB0_215 B NPGE/NPGEP 15 /

    NPS1/NPS1P 13

    4.0B 17.B00 A SFU 0 /

    BISFA

    1.0B 2.B31 CSB034 LVDS lines 1)

    CB0_216 B MXU 8 /

    BISFB

    1.0B 9.B02 A SFU 1 /

    BISFA

    2.0B 2.B08 CSB022 LVDS lines 1)

    CB0_217 B MXU 9 /

    BISFB

    1.0B 11.B02 A SFU 1 /

    BISFA

    2.0B 2.B09 CSB024 LVDS lines 1)

    CB0_218 B MXU 10 /

    BISFB

    2.0B 9.B02 A SFU 1 /

    BISFA

    2.0B 2.B10 CSB018 LVDS lines 1)

    CB0_219 B MXU 11 /

    BISFB

    2.0B 11.B02 A SFU 1 /

    BISFA

    2.0B 2.B11 CSB021 LVDS lines 1)

  • 8/9/2019 CableListe_RNC2600_RU40

    47/48

    Cable Lists for RNC2600

    DN0938288Issue 02D

    © Nokia Siemens Networks 47 (48) 

    Equip.No

    CABLE FROM CABLE TO

    Type Use Note

       C  a   b   i  n  e   t

    FU Position

       C  a   b   i  n  e   t

    FU Position

    CB0_220 B MXU 12 /BISFB

    3.0B 9.B02 A SFU 1 /BISFA

    2.0B 2.B12 CSB022 LVDS lines 1)

    CB0_221 B MXU 13 /

    BISFB

    3.0B 11.B02 A SFU 1 /

    BISFA

    2.0B 2.B13 CSB024 LVDS lines 1)

    CB0_222 B MXU 14 /

    BISFB

    4.0B 9.B02 A SFU 1 /

    BISFA

    2.0B 2.B14 CSB028 LVDS lines 1)

    CB0_223 B MXU 15 /

    BISFB

    4.0B 11.B02 A SFU 1 /

    BISFA

    2.0B 2.B15 CSB030 LVDS lines 1)

    CB0_224 B NPGE/NPGEP 8 /

    NPS1/NPS1P 6

    1.0B 15.B02 A SFU 1 /

    BISFA

    2.0B 2.B24 CSB025 LVDS lines 1)

    CB0_225 B NPGE/NPGEP 9 /

    NPS1/NPS1P 7

    2.0B 15.B02 A SFU 1 /

    BISFA

    2.0B 2.B25 CSB019 LVDS lines 1)

    CB0_226 B NPGE/NPGEP 10 /NPS1/NPS1P 8

    1.0B 17.B02 A SFU 1 /BISFA

    2.0B 2.B26 CSB025 LVDS lines 1)

    CB0_227 B NPGE/NPGEP 11 /

    NPS1/NPS1P 9

    2.0B 17.B02 A SFU 1 /

    BISFA

    2.0B 2.B27 CSB019 LVDS lines 1)

    CB0_228 B NPGE/NPGEP 12 /

    NPS1/NPS1P 10

    3.0B 15.B02 A SFU 1 /

    BISFA

    2.0B 2.B28 CSB025 LVDS lines 1)

    CB0_229 B NPGE/NPGEP 13 /NPS1/NPS1P 11

    4.0B 15.B02 A SFU 1 /BISFA

    2.0B 2.B29 CSB031 LVDS lines 1)

    CB0_230 B NPGE/NPGEP 14 /

    NPS1/NPS1P 12

    3.0B 17.B02 A SFU 1 /

    BISFA

    2.0B 2.B30 CSB025 LVDS lines 1)

    CB0_231 B NPGE/NPGEP 15 /

    NPS1/NPS1P 13

    4.0B 17.B02 A SFU 1 /

    BISFA

    2.0B 2.B31 CSB031 LVDS lines 1)

    1) Cables are connected after the BISFA, BISFB and BISFC back interface units have been installed. Insert the back interface unitcarefully. Check that the locking screws are closed properly, and that the back interface unit is in its place.

  • 8/9/2019 CableListe_RNC2600_RU40

    48/48