HighVoltage
PRODUCTTESTING
CALIBRATION
QUALITYCONTROL
RESEARCH &DEVELOPMENT
Providers of High Voltage Testing Solutions Since 1970Providers of High Voltage Testing Solutions Since 1970Providers of High Voltage Testing Solutions Since 1970
Providers of High Voltage Testing Solutions Since 1970Providers of High Voltage Testing Solutions Since 1970Providers of High Voltage Testing Solutions Since 1970
47
INDEX
AC High Voltage Test Sets
DC High Voltage Test Sets
Impulse Generator
DVDF Test Sets
PLC Based AC/DC High Voltage Test Sets
Testing Trolley
Load Bank Resistive®, Inductive(I) and Capacitive©
Primary Current Injection Test Sets
Secondary Current Injection Test Sets
High Voltage Spark Tester
Oil BDV Test Sets
Continuously Variable Auto Transformers
CT & PT Precision Instrumentation
Rectifier Transformers
Transformer Test Bench
Circuit Breaker Test Sets
Heat Cycle Test Set
Resistive Water Load
Tracking Erosion Index
Electronic Insulation Resistence Meters
Sphere Gap
General Purpose Electrical Test Bench
Motor Test Bench
Capacitive Voltage Divider
Discharge Rods
Capacitor Bank
Short Time Over Current Test Set
Contact Resistance Meter / Mili Volt Drop Test Set
Booster Transformer
Cable Fault Burning Unit
HT Inductor for Tan Delta (Resonating Induc.)
Our Client
2-3
4-5
6
7
8
9
10-11
12-13
14
14
15
16
16
17
18
18
19
19
20
20
21
21
21
22
22
22
23
23
24
24
24
25
ProductName PageNo.
1
20cm x 28cm CMYK
AC HIGH VOLTAGE TEST SETS
Description
“AC High Voltage tester are specially designed for
testing cables, Generators, transformers and other high
capacitive equipments as per National and International
Standards. During manufacturing each unit is tested at
multiple stages, thus ensuring consistency and best
quality. These instruments are air cooled, oil cooled or
air & oil cooled combined as per design. The units have
been manufactured up to 800kV and up to 3000kVA.The
units have type of tests such as dry withstand, wet
withstand, breakdown voltage in air/oil,oil insulation,
and pollution Test.
Light in weight
Casted Wheel for easy movement
Multiple safety locks for the operator
Specially designed for field operation.
Build in safety for operator.
Supplied up to 800KV and 3000KVA.
Special Features
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
2
HIGH CAPACITY UPTO 3000 KVA
LOW CAPACITY UPTO 200 KVA
PLC BASED AC HIGH VOLTAGE
CMYK
20cm x 28cm
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
3
CASCADED TEST SET
BREAKDOWN TEST SETS
PD FREE AC HIGH VOLTAGE
Technical Details Input Voltage 220/230 or 380/400V, 50/60HZ AC Supply
Output Voltage Up to 800KV and 4A, Integration of reactor after 100KVA, Integration of series and parallel reactor after 1500KVA
Partial Discharge Unit
These Units are specially designed for PD testing of samples. We provide PD level as below :
(a) PD Level less than 2pC up to 300kV
(b) Less than 10pC up to 600kV
Capacity Up to 3000kVA
Control Manual Control : The unit can be manual/motorized control for voltage variation and push button controlled for HT actuation
Digitized Control : The unit can be complete with on board digitized panel with or without computer connectivity.
PLC based : The unit can be PLC based complete with computer, HMI memory, printer etc. for operation.
Protection Tripping : A fast acting DC relay will isolate the circuit when the current exceeds pre-set level
Overload : This is used as a secondary protection in case the input loads exceeds the preset value
Over voltage : This is used as a secondary protection in case the output voltage exceeds the preset value
Interlocking Zero Start Interlock : The unit will have zero start interlocking to avoid the transients on HV transformer and provision for cage door interlocking shall also be provided.
Earth Interlock : It ensures that HV will not actuate untill good earthing is not provided
Termination The HT output on suitable HT insulator and other point at earth potential will be brought out on suitable insulator
CMYK20cm x 28cm
DC HIGH VOLTAGE TEST SETS
Description
'RE' Stationary DC High Voltage Test Set is used for testing cables, generators and other electrical equipments as per National and International specif icat ions. The unit consist of Variac, transformer, rectifier, condenser, bleeder, filter etc. All the components are housed in sheet metal housing or specially designed fiber glass housing which are coated with anti tracking paints.
‘RE’ Portable DC High Voltage Test Set is used for testing underground cable, generators, switchgear etc. for understanding the condition of current leakage / insulation condition at any given point. These are extremely light weight units designed for field operation (Substation, Power Projects, Remote sites etc.). The units are delivered in custom made carry boxes to endure rough and rugged transportation.
Easy to operate.
Rugged and compact in construction
Full-wave voltage doubler circuit / Multiplier circuit.
Zero start interlock and earth interlock
Meter accuracy +- 1% full scale
Air Cooled Units / Air and Oil Cooled Units
Digital meters for easy readbility
High Voltage Surge protection
Special Features
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
4
STATIONARY DC HIGH VOLTAGE TEST SETS PLC BASED TEST SET
CMYK20cm x 28cm CMYK
DC HIGH VOLTAGE TEST SETS
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
5
PLC BASED TEST SETPORTABLE RE DC HIGH VOLTAGE TEST SET
TECHNICAL DETAILS Input Voltage 220/230 or 380/400, 50HZ / 60HZ AC Supply
Output Voltage Up to 500KV
Duty Cycle Continuos for testing or 15 minutes at full load.
Capacity Up to 1000mA
Control Type 1 - The unit can be manual control for voltage variation and push button controlled for HT actuation.Type 2 - The unit can be complete with on board digitized panel with or without computer connectivity.Type 3 - The unit can be PLC based complete with computer, HMI memory, printer etc. for operation.
Metering The metering can be provided via resistive voltage divider for direct HT voltage and current measurement.
Termination The negative and positive terminal are brought out on suitable insulator. Positive and negative polarity can be supplied on earth potential on request.
Protection The unit consist of fast acting DC relay which actuates instantaneously if the testing current goes beyond the preset level. The HV will not actuate if the variac is not at zero position (To protect the transformer against transient on HV side and to protect the operator)
Rectifier Silicon diodes with RC networks are used for rectification in bridge or double or multiplier or half wave circuit.
Filter A suitable capacity filter is added to ensure at the ripple is less then 2%.
CMYK
Safety FeaturesSafety Interlock : Alarm, generator auto grounding, over current, over
voltage, and phase protection, emergency stop.Triggering : Manual and automatic trigger arrangement , Triggering signal
can be time delayed.Auto charge function : Constant current charging; Regulation of
charging voltage, charging, time; Charging control in manual or auto.Action Control : The sphere gap follows charging voltage value automatically.Parameter Setting : The gap adjustment is manual / motorized. DC charge voltage, charge time, discharge sphere gap,
Operation triggering mode and polarity switch, etc.
Input Voltage : 380/400V. 50/60HZ
Rated Voltage : Upto +500kV
Rated Capacity : 50kJ
Number of Stages : Upto 5
Stage Capacitance : 1.0μF/100kV
Stage Energy : Variable
DC Voltage Generator : 100kV
Impulse Voltage Measurement : Direct Voltage Measurement
Polarity Reversal : Motorized / Manual
Waveform Measurement : By Impulse Analysing Software.
Impulse Voltage test systems are mainly used to check insulation performance of HV apparatus including Transformers, Reactors, Power Cables, CT/PT/CVT, Insulators, Bushings, Lightning Arrestors, GIS Switchgears, Motors / Generators etc. IVG are mainly used to generate standard lightning impulse full waves, Switching Impulse wave, impulse voltage ranges from 5kV to 500kV, energy from 2kJ to 50kJ.
It can be used to carry out steeping and oscillating impulse test by adding some extra component. It operates with a PLC based control system. Charging time and charging voltage can be selected. Once the selected charging voltage has been reached, a trigger pulse initiates the firing of the lowest spark-gap of the impulse generator. When all the spark-gaps fired all the stages are connected in series thus multiplying the impulse voltage.
The impulse voltage divider reduces the impulse voltage to a value that the measuring and recording instruments require.
Technical DetailsSpecial Features
High Voltage Utilization efficiency
Easy to operate
No Interference effect
Rugged structure
Intelligent Impulse Analyzing Software
Push Button selector for polarity selection
Impulse wave on computer screen
Infinite Back Up Memory
Excellent and efficient service as the product
is indigenously designed.
IMPULSE VOLTAGE GENERATOR
20cm x 28cm
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
6
CMYK20cm x 28cm
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
7
DVDF TEST SETS
Induced Over Voltage Test Set (DVDF) is used for testing the strength of insulation between turns and between other
points of the transformers etc. as stipulated by BIS or other standard specification. For this test Double Voltage is
applied across L.T. terminals for one minute, and to limit the magnetizing current over frequency is utilized.
It is a mechanically coupled unit having motor and Generator with power and control panel to regulate the output
voltage. A suitable control panel is utilized for motor starting, generator output control, measurement of all three phases
voltage and current for input and output with protection circuit.
Maximum Capacity : Up to 10MVA
Input Voltage : 400V 3-phase / 11kV 3-phase beyod 1MVA
Output Voltage : 1000V up to 1mVA
11kV up to 10MVA
Output Frequency : 200HZ
50 to 200HZ
Protection : Overvoltage protection / Overcurrent Protection Overload Protection / Overspeed Protection Frequency Feedback
Generator : Brushless, Slip Ring type
Motor : Induction type
Rated RPM : 1500
PD Level : Induction Generator - NA Brushless Generator - less than 2pC
Mounting : On Vibration pads
Metering : Digital
Control : Manual Control, Digitized Panel, PLC Based System
Motor Starting : DOL up to 10HP Start Delta Starter up to 75HP Soft Starter up to 500HP AC drive beyond 500HP
Motor Generator Coupling : Up to 10KVA - Spring Loading Self aligning After 10kVA - 100kVA - Tyre coupling Above 100KVA - Solid flange coupling
Technical Details
Special Features
No foundation required hence easily
movable with in premises.
No Installation required hence can be
commissioned immediately upon delivery.
Fine Voltage control.
Short Circuit Protected.
Calibrated Voltage and Ampere Meter.
Easy to operate complete with operator
safety features.
CMYK20cm x 28cm
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
8
PLC BASED AC/DC HIGH VOLTAGE TEST SET
Technical Details
Portable Unit for both applications.
For field and project application.
Available upto 300kV AC/DC.
Digital Timer
High Accuracy ± 1% .
Specially designed for capacitor testing.
Bleeder Resistances provided for timer circuit.
Optional controls available for the unit are manual,
motorised or PLC based.
Micro Processor controlled output preset device shall be provided to control the output voltage at the preset
Level.
Actuate the timer as the voltage reaches the preset level.
The timer shall remain ON for the preset time.
The unit shall be complete with annunciation window type indication for convenience.
KV Preset command by time available.
Data transferable to excel format for graphs/charts or over lapping as per the capability of the excel spreadsheet
software.
High Accuracy Data Acquisition Systems with LEM Sensors.
Highly Sensitive Eletromechnical/Mechanical/Proximity Sensors are used for Critical Application.
Various Programmable Parameters.
a) Rate of Rise.
b) Withstand Time etc.
c) Proof Testing.
d) Rate of Fall.
e) Various stages withstand time etc.
f) Ramp up and Setting Menu for upto 5 Stages
Simultaneous monitoring of input and output voltage and current.
Indications for variac at minimum and maximum positions. Emergency OFF screen and control panel.
Indications for LT ON, HT ON, HT OFF, Inc-Dec, In Process, Stage Indicator etc…and a Message window is
Provided for Alerts and Warnings.
Analogue Scale in measurement also available.
Working transferable from auto to manual mode while in operation, vice versa is not possible.
Direct Print facility from provided computer.
20cm x 28cm CMYK
TESTING TROLLEYS
Description
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
9
TRANSFORMER TESTING TROLLEY
SUBSTATION TESTING TROLLEY
SPECIAL PURPOSE TROLLEY
LOAD TESTING TROLLEY
PARAMETERS THAT CAN BE
TESTED
IR Testing up to 5kV
AC High Voltage Breakdown testing up to 80kV, 300mA
Oil BDV Test Set up to 100kV
Full Load and No Load Losses of Transformer by Transformer Test Bench up to 10MVA
Transformer Turns Ratio Test Set
Winding Resistance Meter – up to 25A
IR Testing up to 5kV
AC High Voltage Breakdown testing up to 30kV, 300mA, 3-Phase
DC High Voltage Testing up to 120kV, 10mA
Milli Volt Drop Test Set up to 200A
Primary Current Injection Testing up to 1000A, 3-Phase
Relay Testing Set up to 25A, 3-Phase, with phase shifter
Transformer Turns Ratio Test Set
Winding Resistance Meter – up to 25A
Designed for on shore power application such as
Load Bank
Voltage Controller-Regulator
Rectifier Units
AC Power Supplies
DC Power Supplies
Air craft Generators
Resistive, Inductive and Capacitive Loads up to 3000kW
Manual as well as PLC based.
Available from 0.2pF lag to unity to 0.3 pF lead.
CMYK20cm x 28cm
RESISTIVE (R), INDUCTIVE (L), CAPACITIVE (C) LOAD BANK
Load Banks are designed for load test to be carried on Single/Three
Phase AC/ DC Power Supplies, DG sets, UPS and Inverters etc. We
manufacture loads up to 3000kW suitable for working on Single
Phase 230V +5% and 3Phase 400 V +5% 50HzAC supply. The
power factor in AC can be variable/adjustable from 0.2 lag to unity to
0.3 lead. The capacities are available from 5kW to 3000kW. The
units are available with Stepped & Stepless versions with Manual,
Semi Automatic and Fully Automatic Controllers. Digital Multi
function meters are also available to indicate voltage, current, watt,
KVAr, Pf. The Loads are normally designed for continuous operation
and are forced air-cooled with auxiliary supply with Independent
Controls.
We manufacture following types of Loads:
1.Resistive Loads.
2. Inductive Loads.
3. Capacitive Loads.
4. Resistive/Inductive combined Loads.
5. Resistive/Inductive/Capacitive combined Loads.
Each load banks consist of coarse and fine controls as per the specific requirements.
Description
Inductive & Capacitive Load Bank Resistive Load
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
10
Special FeaturesMultiple interlocks for human safety.
Computer interface facility.
Fully Automated Systems available
Build in safety for operator.
Compact in size
Design is Cascade Fashion
Temperature sensors are provided in the load banks.
Load ON-OFF switches with indicator.
Inductive loads manufactured by us noiseless.
Fans are mounted as per the design and requirement of the unit.
Push button for energizing & de-energizing loads with indication.
Push Button for fine control of Load Bank.
Adaptable to Technology Change
Upgradable to Higher Capacities
Versatile Operation
Designed for Various sites, Location and Weathers.
IP 44 Protected.
Standalone Single unit Upto 1000kW @ 0.6 PF.
Designed for Low Heat Generation and Operation within 150°C.
Designed for use in Ambient Temperature Upto 55°C.
Air conditioned Control Room Operated by Aux./Load Supply.
CMYK20cm x 28cm
RLC LOAD BANK
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
11
TECHNICAL DETAILPARAMETERS RESISTIVE LOAD BANK INDUCTIVE LOAD BANK CAPACITIVE LOAD BANK
Capacity 5kW to 3000kW 5kW to 3000kW 5kW to 3000kW
Input Supply Voltage 220/230V, 50/60HZ or 380/400V, 50/60HZ Supply
220/230V, 50/60HZ or 380/400V, 50/60HZ Supply
220/230V, 50/60HZ or 380/400V, 50/60HZ Supply
Frequency 50HZ/60HZ 50HZ/60HZ 50HZ/60HZ
Cooling Forced Air Forced Air Forced Air
Controls MCB / Contactor / PLC
Based
MCB / Contactor / PLC
Based
MCB / Contactor / PLC
Based
Material Used SS-304 / Nicrome Standard inductors Standard Capacitors
PLC RLC LOAD BANK
CMYK20cm x 28cm
PRIMARY CURRENT INJECTION TEST SET
Description
Supplied upto 25000 Amps.
Various Features and Functions upon Request
Electronic Parameter Monitoring
Multiple safety locks for the operator
Build in safety for operator
Efficient after sales service
Guaranteed for one year against manufacturing defects only
Special Features
Primary Current Injection Test Sets are used to loading, Calibration and testing of CT's bimetals relays, Protection relays etc. Mostly Primary Injection Test set are designed as per customer's specification.
The Primary Injections Test sets are of 15 minutes ON/30Minutes OFF duty i.e. testing duty only. Loading transformers are design for continuous use for Temperature Rise or bus duct/Bus Bar etc.
Optional accessories requirement may include cable termination, timer, Temperature Indicator, multiple contactor, individual Phase control etc. Equipments are Compact in nature.
It is available in portable trolley type/stationery type model Amps. Optional digital/analogue timer. Main Transformer up to 25,000 Amps.
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
12
CMYK
PRIMARY CURRENT INJECTION TEST SET
13
Technical DetailsParameters Three Phase PCITS Single Phase PCITS
I/P Voltage 380/ 400V Three Phase 50/ 60HZ AC Supply. Single Phase or two phase 50/60HZ AC Supply
O/p Current Up to 25000A Same as for Three Phase
Capacity Up to 500KVA Up to 100kVA
Duty Cycle Intermittent or countinous Same as for Three Phase
Control The unit can be manual/motorized control for current variation and push button controlled.
The unit can be microprocessor based complete with on board digitized panel.
The unit can be PLC based complete with computer, HMI memory,printer etc. for operation.
Same as for Three Phase
Power Components
Step down transformer : 3 Nos. double wound transformer shall be used for supplying high Current and low voltage for testing.
Auto Transformer : 3 Nos. Motorized Auto Transformer shall be used for controlling the output voltage from zero to maximum to control the load Current.
One no. step down and one no. auto transformer is required.
Metering Ampere meter : 3 Nos. Digital Ampremeter shall be provided with 0.5 classes CT to indicate the output current. The size of the amperemeter shall be 96 sq.mm.Voltmeter : A digital voltmeter with selector switch shall be provided to indicate the output voltage each phase/phase to phase, if required.Line On Indicator : Neon lamp indicators are provided for input indication.Main ON/OFF switch : Three pole ON/OFF is provided for input ON &OFF.
Ampere Meter : One no. Ampere meter is required. Main ON/OFF switch : Two pole ON/OFF is provided for input ON & OFF. Rest is same as for three phase.
Termination Output is brought on Copper bus-bars Same as for Three Phase
Control Panel (I) ON/OFF switch(ii) Separate indication lamps for all three phases in three phase unit.(iii) Digital Output Ampere meter and Voltmeter with selector switch.(iv) Push buttons for raising and lowering the Output current separately for each phase with change over switch and Push buttons for raising current of all the phases simultaneously.
Same as for Three Phase
CMYK
CMYK
Secondary Current Injection Test Sets have been designed keeping in view the requirements of field and laboratory. The sets are portable, light in weight, yet have all the technical features required for testing relays and contractors etc. Our Equipment are Compact in size and have Built in safety arrangements in case of short circuit and over loading, These units are easy to operate. We have efficient after sales service and products are guaranteed for one year against manufacturing defects. These units are available in single phase and Three phase units.
HIGH VOLTAGE SPARK TESTER
RE High voltage spark testers are designed for checking the quality of insulation coated wires for pin holes / weak insulation / exposed conductor during manufacturing at work floor. The wire is passed through brass ball beads which carry high voltage. If any pin hole is detected in PVC, a spark develops and electro magnetic counter counts the fault. The spark tester is necessary for every cable manufacturing unit. Spark Testers can be used for high speed extruders and high speed Recoiling processes. The efficiency of Spark Tester is up to 95%.
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
SECONDARY CURRENT INJECTION TEST SET
14
TECHNICAL DETAILSI/p Voltage : 230/240 Volt 50 Hz. AC Supply, single phase
Test Voltage : Up 50KV
Test Frequency : 50HZ
Dia. Range : Up to 150mm
Line Speed : 300 m/min.
KV Meter : Analog or Digital display as required.
Indicator : (a) LT ON,
(b) HV ON,
(c) HV OFF,
(d) Fault (Audio & Visual)
Fault Counter : Electro-Mechanical / Digital (resettable)
Protection : (a) Input Fuse,
(b) Short circuit protected
Duty Cycle : Continuos
Control : Trip or bypass available
Designed for extruder and recoiling operations.
Height adjustable Electrode box
Compact size.
Built in safety features for operators
Easy to operate.
Recoiling shutdown as per operator setting.
Special Features
Light in Weight
Instantaneous operation of less than 2mS
Until design for AC/DC voltage current and relays
Suitable for Static as well as Electromechanical relays
Special FeaturesInput Voltage: Single phase 50HZ AC Supply
Output Current : Up to 100A
Output Voltage : 0-400V AC,
0-400V DC
Duty Cycle : As required
Technical Details
THREE PHASE SINGLE PHASE
Input Voltage : 380/400V Three phase 50 HZ AC Supply
Output Current : Up to 100A
Output Vltage : 0-400V x3 AC, 0-400V DC
Duty Cycle : As required
Technical Details
CMYK20cm x 28cm
OIL BDV TEST SETS
Oil BDV Test set are designed for testing the dielectric strength of insulating oil as per IS-335. The unit develops high voltage between electrodes immersed in oil under test as per IS:6792. In addition to the test preparation in detail, the set is automatically governed by a trouble-free Microprocessor.
These features enable user to operate the equipment with a single touch of the 'Feather Touch Button'. The results can be viewed on the backlit LCD display or can be printed as a hard copy. The results can be summarized at a later stage because of the presence of memory function for the tests conducted stored in the memory.
These units are capable of conducting tests on transformer oil as per National / International standards such as IEC, ASTM, UNE, BS, VDE etc.
Description
Compact size & portable design
Build in safety arrangements
Easy to operate
Auto / Manual Selectable
One Touch Operation
On Screen LCD & Printer Facility on the Unit
Real Time Clock & Date
9999 record Memory
Computer Connectivity through USB/RS232
Operator code porgrammable
Rate of rise of voltage 0.5kV/sec to 5.0 kV/sec
Special Features
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
15
FULLY AUTOMATICSEMI AUTOMATICMOTORIZED
Parameters Motorized Oil Test Set Semi Automatic Oil Test Set Fully Automatic oil Test Set
Rate of Rise 2KV/sec 2KV/sec 0.5 to 5KV/ Sec
Operation Individual ( After every reading user has to reset)
One touch Operation One touch Operation
Average Calculation Manual Yes Yes
Memory Individual Reading (Only for current test)
Present test untill reset / Power Off
Previous 9999 Tests
Printout No No Yes
Computer Compatibality No No Yes RS 232
EMI/EMC Protection No Yes Yes
Safety as per IEC61010 No Yes Yes
Display Analog/Digital LCD 1” x 1” Alpha Numeric Yes 16 x 2 Character Alpha Numeric
Technical Details
CMYK
20cm x 28cm
CONTINUOUSLY VARIABLE AUTO TRANSFORMERS
'RE' VARITX is the trade name of the continuously variable voltage Auto transformer manufactured by 'RE'. It is an most economical effective device for step less and continuous voltage control of Single Phase and 3 phase AC voltages for numerous applications for the industrial and Laboratories usages for testing and calibration purposes.
'RE' VARITX are used for operation at nominal voltage of 240V AC to give output Voltages between 0 to 270V at 50/60 Hz by a Booster Auto Transformer. Three such 'RE' VARITX connected electrically in star and mechanically interlocked to move together are used for operation on 415 Volts, 3 phase AC supply to give output from voltage from 0 to 470 Volt at 50/60Hz.
'RE' Manufactured VARITX is having good Regulation with Negligible waveform distortion. VARITX are robust, energy efficient, noiseless and easy to operate with excellent short time over load capabilities.
'RE' manufacturers special ized Oil cooled or air cooled motorized/manually operated VARITX upto 800 Amps with supply voltage of 240 Volts to give output voltages from 0 to 350 Volts, 3 Phase VARITX up to 800Amps with input supply voltage of 415 Volt 3 Phase to give output Voltages from 0 to 600V.
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
16
Maximum Current Rating : Up to 2000A
Input Voltage : Single Phase and Three Phase depends on capacity
Output Voltage : Variable
Designed For : Continuos use
Types : Open Manual (Air Cooled)
Enclosed Manual (Air Cooled)
In Tank Manual (Oil Cooled)
Confirms To : IS : 985
Operating Temperature : 0°C to 50°C
Humidity : Up to 95% RH
Technical DetailsSpecial Features
Compact in Size.
Rugged Construction.
High Efficiency
Neo zero waveform distortion.
Digitized operation and control and monitoring
Easy to operate.
Negligible maintenance trouble free operation.
Current Transformer (Class 0.1) (Available upto 33kV)
0-5 /10/30 Amps // 5/1 Amps Resin Cast
0-150/300 Amps // 5/1 Amps Resin Cast
0-150/300/600/1200 Amps // 5/1 Amps Resin Cast
Potential Transformer (Class 0.1)
0-1.13 / 2.2 kv3 / 3.3 kv3 // 110 V3 Resin Cast
0-6.63 / 11kv3 / 333 kv // 110 V3 Resin Cast
CT & PT PRECISION INSTRUMENTATION
CMYK20cm x 28cm
RECTIFIER TRANSFORMER
Description
Highest Rating Available
Various Features and Functions upon Request
Electronic Parameter Monitoring
Multiple safety locks for the operator
Build in safety for operator
Efficient after sales service
Guaranteed for one year against
manufacturing defects only
Special FeaturesThese are manufactured for various purposes
like electroplating, anodizing, chemical
processes, and power supplies for Magnetic
Charger, Battery Charger, Copper and silver
refining and Drying Large Generator, Motor,
Transformer etc. Each of the above listed
products are a field of their own.
The rectifier transformers are designed for
continuous use for which they can be air and/or
Oil Cooled. We have so far supplied upto 10,000
amps, 480V maximum. The electronic controls
can be provided which are used for various
functions options like, current density control
and voltage control, temperature, speed control
etc.
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
8
INPUT VOLTAGE : 230V single phase or 415V
three phases 50HZ AC supply
OUTPUT VOLTAGE RANGES : From 6V DC to 500V DC or as per
Customer Requirement
OUTPUT CURRENT : Diode Based or Thyristorised
OUTPUT CURRENT : Upto 10000 ampere or as per
Customer Requirement
CAPACITY : Upto 2400 kW
DUTY CYCLE : 100 % Duty Cycle
Technical Specs
CMYK
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
18
TRANSFORMER TEST BENCH
'RE' Transformer Test Bench is a desk type panel interface provided for
transformer testing. It houses test instruments, selector switches, Push
Buttons, indicators, meters and HMI. The test engineer can exercise control
through the test bench and can monitor various parameters related to
testing equipment such as HV Tester, MG Set, Isolators, Breakers and
many more. The above functionality is made more sophisticated with the
use of a PLC and LCD touch screen based HMI. When the PLC and HMI are
used; discrete indicators, meters, SS and PBs become redundant. SLD of
the whole power circuit then can be visualized and controlled through the
HMI.
Acquired on-line data from test instruments, and printing reports that are
compliant with all national and international standards such as IS-2026,
IEC-60076, ANSIC57, IS-11171 CBID & SABS, IS-1180 etc.
PLC based test bench consist of Transformer Test bench, power panel,
High Voltage, MG Set, standard C.T.'s /P.T.'s , Booster Transformer, Power
Harmonics Analyzer.
Capacity up to testing all kind of transformer up to100MVA.
Automatic operation of Dimmer, Generator and voltage setting,
C.T. / P.T. selection.
Automatic Report generation.
Visibility of every parameter of screen
Designed for all makes and models
Reduces test time and human error free.
Error-free transformer test reports with print-on-demand facility
Provides for easy storage and retrieval of test reports
Facility of entering data manually.
Along with the detailed report format, PLC test bench has the short report facility which gives the report of the routine test.
Database backup facility to take the backup of database in the hard drive.
Special Features
The unit is designed for testing trip timing as well as thermal overload. The unit can also be used to test relay through current transformer. We can also test trip timing . The maximum Capacity of the test set is 2000A and the same can be increased as per customer requirement.
CIRCUIT BREAKER TEST SETS
CMYK20cm x 28cm
Heat Cycle Test Systems are designed to raise and control the temperature of a conductor or other low impedance electrical loop to simulate the current loading conditions found in electrical circuits.
This heating is achieved by utilizing the test loop as the secondary winding of a current transformer for inductive heating. Measurement of the loop temperature is made by direct contact of a K-type thermocouple probe with the conductor of the test loop.
Our systems are offered as low voltage test systems or high voltage test systems. The low voltage test system utilizes one loop of the conductor passing through the desired number of CT carts to reach the necessary current level. Additionally Impulse tests can be performed on the high voltage side of the test set up.
Designed for working on 400V, 2 Phases of 3phase AC supply. Supplying up to 6000 Amperes in cables loop of up to 15 meter of suitable capacity. Various other optional accessories are available including advance control system.
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
19
Input Voltage : 380 / 400V 2 phase 50/60HZOutput Current : Up to 6000ATemp. Thermocouple : K-type(Optically isolated) or fibre optic type Cable length : Upto 15 meter Current Injection carts : Each capable to 750Amps No. of carts : Upto 7Heating Control : PID controlled with zero interlock bypassTimer : Upto 30 days Ampere Meter Range : Range : As per capacity Accuracy : 0.5%
Technical Details
HEAT CYCLE TEST SET
Special Features
Type K thermocouples
Safety Interlocks
Automatic and manual control of test sequences
Timer for up to 900hours
Zero start inter-lock
Mobile CT carts with castors
Updateable software
Main Power Breaker
Inductive Current Compensation
RESISTIVE WATER LOAD
Resistive water load is used to keep the fault current under check. This ensures that whenever there is a flashover or a failure in the sample.
The load acts as a bottleneck limiting the amount of fault current generated does ensuring safety and long liberty of the equipment and prevention of sample from a total burnout. This also ensures prevention of any damage around the faulty sample.
CMYK20cm x 28cm
Tracking Resistance Erosion Test Equipment is used for checking the relative behavior of solid electrical insulating material with regard to their susceptibility to surface tracking when exposed under electric stresses, to water and contaminants, from the surroundings.
The grading of materials arrived at by checking the tracking index may possibly differ from that obtained by utilizing other checking methods for the measurements of the tracking index.
The results obtained by checking tracking index are not used directly for evaluation of safe creepage distances while designing any electrical apparatus.
With this apparatus drops of an electrolyte are dropped at defined time interval to the surface of insulating materials between two electrodes to which a voltage is applied.
The number of drops at which break down occurs across the surface is the function of voltage
The numerical values of the voltage corresponding to the asymptotes defines the tracking resistance. The value of voltage corresponding to number of drops is taken as the comparative index. (This test should be done as fast as possible)
The number of drops to cause tracking at value of predetermined test voltage 10% below the number of drops value is indicated as the degree to which the reported comparative tracking .
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
20
Input voltage : 220/ 230 Volts, Single phase 50/60 Hz. AC supply.
Output voltage : 0-10KV
Output Current : 100mA
Capacity : 1 KVA
Rating : Testing duty (Continuous).
Cooling : Air cooled.
Technical DetailsSpecial FeaturesTechnologically advanced design that helped make proper use of space and minimize the size of the equipment.
Zero start interlocking, earthing, electrode box, cage door interlocking are some of the features that make the equipment very safe for the user.
The equipment has been made so that it is very simple to operate, thus any person after learning once can operate it
TRACKING EROSION INDEX
hey are designed for measurement of Tinsulat ion materials, Electr icals & Electronics Components, Cables, Panels, Transformers, Chokes, PCB's Plugs & Sockets and many similar products.(500 V DC to 10000 V DC ).
ELECTRONIC INSULATION RESISTANCE METERS
MIC 5005
CMYK
For Testing Motors, transformers and electrical Equipment etc. The Test Panel shall be suitable for 3 phase input supply having 100 Amp MCB for each phase independently. Phase ON Indicator, Voltmeter with selector switch to indicate the voltage of each phase. Ampere meter with Multi range CT of 5/5, 5/15, 5/30 and 5/60 A of class 0.5 accuracy for each phase, 3 Phase watt meter of suitable range.These units can be customised to accommodate various instruments from our manufacturing range or customer requirement.
GENERAL PURPOSE ELECTRICAL TEST BENCH
ALL 3 Points are same.For upto 700 kW Motor.No Load Tests.Test bed available for various size motors.Single test bed for variable frame / motor size.Complete with insulation resistance, winding resistance,high voltage, power analyzer.
MOTOR TEST BENCH
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
21
RE' Sphere Gap is provided with Motorised arrangement to adjust the gap.The lower sphere gap shall in Motorised and shall move upwards and downwards for the adjustment of gap.The upper sphere shall hang from the roof of the test lab with in insulator and current limiting resistance shall be provided.Available upto 500mm Sphere supplied upto 300mm sphere.Digital distance measurement.
SPHERE GAP
CMYK20cm x 28cm
A Capacitive Voltage Divider can be used to measure AC Voltage and from any high voltage source such as a testing equipment, A PT or a power/Distribution Transformer. The unit comes with specific metering to ensure accurate & consistent results.
‘RE’ Capacitive Voltage Divider offers Digital Meter for easy use and readability. As the metering unit is battery operated, the effect of variation and input voltage coming to the meter is negated, this generates a more stable platform for measurement. The unit also has an in-built battery charger and a recharge indicator.
CAPACITIVE VOLTAGE DIVIDER
arthing/Discharge Rods for upto 800KV Esystem and above with Low Maintenance, Moisture Resistance 'F' Class Insulation 100 % Safe for operator, Excellent Di-electric Properties, Unmatched Mechanical strength suitable for high wind velocity areas, High temperature withstand capability, Light weight allows one person to handle the rod easily.
DISCHARGE RODS
600 KV 50 KV 100 KV
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
22
The capacitor bank is used for improvement of power factor during load losses measurement of power transformer three phase 500 Volt shunt capacitor bank in the form of 100kVAr & 20kVAr banks.Available 2000kVAr banks manually controllable Automatically.
CMYKCMYK
Contact Resistance Meter is capable to measure
contact resistance upto 19.99 mΩ. The
instrument can provide test current between 20-
100/200....600Amps subject to the load
resistance and supply voltage. The system uses
fou r t e rm ina l s me thod fo r r es i s tance
measurement. The unit is microprocessor based
complete with printer, inbuilt memory.
CONTACT RESISTANCE METERS / MILIVOLT DROP TEST SET
MILIVOLT DROP TEST SET
The equipment is designed for supply high current for pre-set duration. The unit consist of a timer, Ampere meter with freezing facility to measure the short duration current The equipment has provision for stepless control of the normal control and setting of 500ms & 10ms, 20 times, 30 times the rated current. The output is brought out on copper bus bar. The unit is complete with Ampere meter, Timer, 0.5 class.
SHORT TIME OVER CURRENT TEST SET
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
13
Milli Volt Drop Test Set model MVDTS-0-
100/200...3000 Amp is capable to measure Milli
Volts between 1mV to 2000mV. The instrument
can provide test current between 0-100/200..3000
Amp subject to the capacity chosen, load
resistance and supply voltage. The system uses
four terminal method - two for current supply and
two for measurement. The Unit has high current
capability and is of compact design suitable for
testing high current contacts of circuit breakers,
switches, bus-bar joints and other application
where high current junctions exist.
CONTACT RESISTANCE METER
CMYK20cm x 28cm CMYK
esonating Inductor for range extension of Rtype FT-12 Capacitance and Power Factor Field Test Set
Rated Voltage : 12kV Max. Current : 4.0 A, With Current Indication on both sides for easy turningOutput : 12 KV Insulated Cable with pin glandsLocation Indicator : AvailableCooling : Air Natural, Resin CastLeakage Current : I < 300mA
HT INDUCTOR FOR TAN DELTA (RESONATING INDUC.)
Converts high resistance faults to short circuit faults.Available for HV/LV cables.For manufacturers use only.Helps save the undamaged part of cable.Helps utilize the TDR.LV Fault Burner upto 30 kVA.HV Fault Burner upto 70 kVA.
CABLE FAULT BURNING UNIT
Booster transformer upto 2000kVA are on 415 three phase 50HZ Supply. Designed to deliver output 0-750/1500/3000V three phase.The unit shall be designed for continuous use at full load.The units are Air / Oil cooled.The units are custom designed to suit customer requirement.
The above picture is only a representation of the equipment and the actual equipment may vary as per specification, design & requirement
24
25
HQ & Mfg Unit - 1: Mfg Unit - 2: 10/3, DLF Industrial Area, Moti Nagar, New Delhi-110015, INDIA 296, IMT Manesar, Haryana - 122050
Tel: Fax: E-mail: Web: 91-11-43680100 (10 Lines) 91-11-41425853 [email protected] www.re-india.com
Rectifiers & Electronics Pvt. Ltd.AN ISO 9001:2008 & ISO 14001 COMPANY