SS-DBC6 www.daikinac.com 01/21 Supersedes 10/20 DBC Commercial Base Efficiency Air Conditioner Belt-Drive Packaged Rooftop Unit DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER * Complete warranty details available from your local distributor or manufacturer’s representave or at www.daikincomfort.com or www.daikinac.com

DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

  • Upload
    others

  • View
    24

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

SS-DBC6 www.daikinac.com 01/21Supersedes 10/20

DBC Commercial

Base Efficiency Air Conditioner Belt-Drive Packaged Rooftop Unit

DBC Commercial6 Nominal Tons

15 IEER / 11.2 EER

* Complete warranty details available from your local distributor or manufacturer’s representative or at www.daikincomfort.com or www.daikinac.com

Page 2: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

2

Our Perfect Package:Harnessing energy-efficient performance, proven technology, and enhanced comfort for life.

Since becoming the first company in Japan to manufacture packaged

air conditioning systems, in 1951, Daikin has supported comfortable

indoor living based on the strengths and technologies that have

led to the growth of the company becoming one of the

world’s largest manufacturers of HVAC products, systems

and refrigerants.

Today, as a comprehensive global manufacturer of HVAC products

and systems, the Daikin brand is committed to being recognized

as a truly global and excellent company capable of continually

creating new value for its customers. The company plans to pursue

sustainable growth and foster business operations that consistently

harmonize with the goals of improving indoor comfort.

The group philosophy of the company includes: » Creating new value continuously for customers

» Developing world leading energy-saving technology

» Being a flexible and dynamic organization

» Allowing employees to be the driving force for the success of the company

» Fostering an atmosphere of best practices, boldness, and innovation

» Thinking and acting globally

Page 3: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

3

Contents2 Introduction 2

4 Nomenclature 4

5 Features and Benefits 5

Applications 8Serviceability 8

9 Product Specifications 9

Coil Dimensions 9AHRI Ratings 9Sound Data 9Expanding Cooling Data 10Electric Heater Data 12

Air Flow 13Static Pressure 14Electrical Data 15Wiring Diagrams 18

19 Dimensional Data 19

20 Electrical Connections 20

Unit Clearances 20Installation 21

Weights 21

22 Accessories 22

24 Factory Installed Options 2

25 Field Installed Options 25

25 Factory and Field Installed Options 25

Page 4: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Nomenclature

4 www.daikinac.com SS-DBC6

D B C 072 3 V XXX A X A

1 2 3 4,5,6 7 8 9,10,11 12 13 14

BrandD Daikin

ConfigurationB New Base Efficiency

ApplicationC CoolingG Gas Heat

Nominal Cooling Capacity072 6 Tons

Voltage3 208-230/3/60 4 460/3/60

7 575/3/60

Supply Fan/Drive Type/MotorV 2-speed Belt-Drive - Standard StaticS 2-speed Belt-Drive - High-Static

Nominal Heating CapacityGas/Electric A/C H/P Factory-Installed Electric Heat090 90,000 BTU/h XXX No Heat115 115,000 BTU/h 005 5kW140 140,000 BTU/h 010 10 kW

015 15 kW018 18 kW020 20 kW030 30 kW

See product specifications for heat size(s) available for each capacity.

Refrigeration SystemsC Two-stage cooling modes

Heat Exchanger

X No optionsA Standard Aluminized ExchangerS Stainless Steel Exchanger

ControlsA Electromechanical controls

X X X X X X X X A *

15 16 17 18 19 20 21 22 23 24

Revision Levels

Major & Minor

X No Options

Power Exhaust

X No OptionsB Single-point power connection for Power Exhaust

IAQ

X No Options

Service OptionsX No OptionA Powered convenience outletB Non-powered convenience outletC Hinge PanelsD Hinged Panels and Powered convenience outletE Hinged Panels and non-powered convenience outlet

ElectricalX No OptionsA Non-Fused DisconnectB Phase MonitorC Thru-the-base connectionsE Non-Fused Disconnect and Phase MonitorF Non-Fused Disconnect and Thru-the-base connectionsH Phase Monitor and Thru-the-base connectionsL Non-Fused Disconnect, Thru-the-base connections and Phase Monitor

EconomizerX No OptionsA Ultra Low-Leak Downflow Economizer w/Enthalpy SensorB Low-Leak Downflow Economizer w/Enthalpy SensorG Ultra Low-Leak Downflow Economizer w/Dry Bulb SensorH Low-Leak Downflow Economizer w/Dry Bulb Sensor

Hail guard X No OptionsC Hail Guard

SensorsX No OptionsA RA Smoke DetectorB SA Smoke DetectorG Ultra Low-Leak Downflow Economizer w/ Dry Bulb SensorH Low-Leak Downflow Economizer w/ Dry Bulb Sensor

AC Stocking ModelsNew Daikin 6 Ton

Model Number Code stringDBC0723V000001S DBC0723VXXXCXAXXXXXXXXDBC0724V000001S DBC0724VXXXCXAXXXXXXXXDBC0727V000001S DBC0727VXXXCXAXXXXXXXX

Page 5: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Features and Benefits

SS-DBC6 www.daikinac.com 5

Installation Daikin Packaged units are designed with fast and easy installation in mind and are ideal for both new construction and retrofit projects. Our packaged rooftop units are built to be a direct replacement for most rooftop units on the field without the need of a curb adapter, to be able to replace the unit in a shorter time and at a lower cost (compared to the previous design).

Cabinet Construction Daikin packaged rooftop units are made with high quality galvanized steel with a powder-paint finish to provide higher corrosion resistance.

» Easy accessibility using our tool-less filter access.

» The interior surface in the indoor air section is fully insulated to prevent sweating and thermal losses, using our foil face fiberglass insulation which also omits exposed filter fibers into the airstream.

» 1" Raised flanged edges around the supply and return offer easy installation for the duct connections.

» The full perimeter base rail is built using heavy gauge galvanized steel for a stronger structural installation, the base rails are a minimum of 3 ½” tall and include holes to allow for overhead rigging and lifting with forklifts.

» Electrical lines and can be brought through the base of the unit or through the horizontal knockout for easy installation and accessibility on the field.

Compressor High performance, low noise scroll compressors with stage control to match the required total load for efficient part load control.

» Resiliently factory-mounted on rubber grommets for vibration isolation

» Refrigeration circuit includes both low- and high-pressure transducer, high pressure safety switch and temperature sensors for the suction and discharge.

» Unit is factory charged with environmentally friendly R-410A refrigerant.

» Two-stage scroll compressor for partial load applications.

» Compressor location outside the condenser section to avoid air bypass.

» Internal overload protection included with compressor.

Supply Fan Indoor forward curb fans paired with belt-drive motors provide an easy in the field belt and pulley adjustment for airflow control.

» Slide out forward curb fan for easy maintenance and replacement.

» High-static drive options for application with high airflow/static requirements.

» Each fan assembly is dynamically trim balanced at the factory before shipment for quick start-up and efficient operation.

» Motor with thermal overload and phase failure protection is provided for motor long lasting operation.

Daikin Packaged Rooftop Units (RTUs) are built to perform, with features and options that help provide low installation and operation costs, superior indoor air quality, efficient operation, and longevity.

Page 6: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Features and Benefits

6 www.daikinac.com SS-DBC6

Coils All units use large face area outdoor coils. These coils are constructed with seamless copper tubes, mechanically bonded into aluminum plate-type fins with full drawn collars to completely cover the tubes for high operating efficiencies.

The indoor coil section is installed in a draw through configuration to provide better dehumidification.

» Coils are factory pressure tested to ensure pressure and leak integrity.

» Copper tube / aluminum fin coils on condenser and evaporator

» 5mm Smart Coil Technology on all condenser coils for improved performance and reduced refrigerant load.

Controls and Wiring Packaged rooftop units come equipped with a well-organized, large, easy to use weatherproof internal control box with easy access, for a better user experience.

» Units are factory-wired with labeled color-coded wires and complete 24-volt Electromechanical controls package.

» Units include single-point power entry as standard and also available with electric heat kits if selected.

» Terminal blocks are provided as standard for easy installation and field power wiring.

Filtration Unit provides a draw-through filter section as standard for better air quality and long lasting component maintenance.

» Filters installed on the units are standard off the shelf sizes for easy replacement.

» One or two size filter per unit for low maintenance cost and easy replacement.

» Easy and fast filter service access.

Heating Section Wide ranging of electric heat selections effectively handle most comfort heating demand from morning warm-up control to full heat.

Electric Heat ETL approved electric heat is factory assembled, installed and tested.

» Heating control is fully integrated into the unit’s control system for quick start-up and reliable control.

» Durable low watt density, nickel chromium elements provide longer life (compared to units without)..

» Fuses are provided in each branch circuit to a maximum of 48 Amps per NEC requirements.

» Single-point power connection reduces installation cost.

» For operational safeties electric heat includes automatic reset, and high temperature limit safety protection and an airflow safety switch to prevent electric heat operation in the event of no airflow.

Electrical Units are completely wired and tested at the factory to provide faster commissioning and start-up.

» Wiring complies with NEC requirements and all applicable UL standards.

» For ease of use, wiring and electrical components are number coded and labeled according to the electrical diagram.

» A 120 V GFI convenience receptacle requiring independent power supply for the receptacle is optional.

» An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary overload protection, eliminates the need to pull a separate 115 V power source.

» Supply air fan, compressor, and condenser fan motor branch circuits have individual short circuit protection. Unit includes knockouts in the bottom of the main control panels for field wiring entrance.

» A single-point power connection with power block is standard and a terminal board is provided for connecting low voltage control wiring.

» For better serviceability an optional non-fused disconnect switch can be installed inside the control panel and operated by an externally mounted handle to disconnect the electrical power at the unit

Page 7: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or
Page 8: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Applications & Serviceability

8 www.daikinac.com SS-DBC6

ApplicationsDaikin Rooftop units are intended for comfort cooling applications in normal heating, ventilating, and air conditioning. Consult your local Daikin sales representative for applications involving operations at high ambient temperatures, high altitudes, non-cataloged voltages, or for job-specific unit selections that fall outside of the range of the catalog tables.

For proper operation, units should be rigged in accordance with instructions stated on the installation manual. Fire dampers, if required, must be installed in the ductwork according to local and/or state codes. No space is allowed for these dampers in the unit.

Follow factory check, test and start procedures explicitly to achieve satisfactory start-up and operation.

Most rooftop applications take advantage of the significant energy savings provided with economizer operation. When an economizer system is used, mechanical refrigeration is typically not required below an ambient temperature of 50°F.

Serviceability Daikin packaged rooftop units are built with serviceability in mind, designed to make future maintenance and service on the unit easy and accessible.

» Our packaged rooftop units offer a slide out blower to facilitate the access and removal of the fan.

» Filter panels on the small chassis line offer tool-less access for easy maintenance.

» Independent compressor outside of the air bypass to eliminate component blockage and provide easy access.

» Labeled field connections, color coded and continuously marked wire to identify point-to-point component connections.

» All 3 - 5 ton units are designed for convertible airflow orientation to serve downflow or horizontal applications. Every unit ships prepared to convert to horizontal orientation in the field if required.

» Condenser clean out from inside-out.

» Easy access to gas valves and control panel.

Page 9: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Product Specifications

SS-DBC6 www.daikinac.com 9

DBC072 - Standard

Model DBC0723V000001S DBC0724V000001S DBC0727V000001SCOOLING CAPACITYTotal BTU/H 69,000 69,000 69,000IEER / EER 15.0 / 11.2 15.0 / 11.2 15.0 / 11.2AHRI Reference # 205301569 205301569 205301569EVAPORATOR MOTOR COILMotor Type 2-Speed Belt-Drive 2-Speed Belt-Drive 2-Speed Belt-DriveExternal Static Pressure (ESP) Standard Standard StandardWheel Dia. X Width 12x10 12x10 12x10Indoor Nominal CFM 2130 2130 2130RPM 1740 1740 1745Indoor Horsepower 2.00 2.00 2.00

Filter Size (in)14 X 20 X 2 (2)20 X 20 X 2 (2)

14 X 20 X 2 (2)20 X 20 X 2 (2)

14 X 20 X 2 (2)20 X 20 X 2 (2)

Drain Size (NPT) ¾ ¾ ¾R-410A Refrigerant Charge (oz.) 154 154 154Evaporator Coil Face Area (ft²) 9.2 9.2 9.2Rows Deep/ Fins per Inch 4/16

4/164/16

CONDENSER FAN/COILQuantity of Condenser Fan Motors 1 1 1RPM (High/Low stage) 1122 1050 1050Outdoor Horsepower 0.33 0.33 0.33Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4Face Area (ft²) 19.0 19.0 19.0Rows Deep / Fins per Inch 2 / 28 2 / 28 2 / 28COMPRESSORQuantity / Type / Stages 1 / Scroll / 2 1 / Scroll / 2 1 / Scroll / 2Compressor RLA / LRA 17.6 / 136.0 8.5 / 66.1 6.3 / 55.3ELECTRICAL DATA Voltage-Phase-Frequency 208/230-3-60 460-3-60 575-3-60Indoor Blower FLA 6.0 2.9 2.4Max External Static (In. W.C.) 1.8 1.8 1.8Outdoor Fan FLA 2.0 0.85 0.67Min. Circuit Ampacity¹ 30.0 / 30.0 14.3 11.0Max. Overcurrent Protection (A)² 45 / 45 20 15Power Supply Conduit Hole Dia. (in) 1.125 1.125 1.125Low-Voltage Conduit Hole Dia. (in) 0.5 0.5 0.5OPERATING WEIGHT (LBS.)Operating Weight (lbs) 678 678 678SHIPPING WEIGHT (LBS.)Ship Weight (lbs) 724 724 724

¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed.

MODEL CAPACITY EER IEERDBC0723/DBC0724/DBC0727 69000 11.2 15

AHRI Ratings Sound DataModel Outdoor sound (db) at 60 Hz

A-Weighted 63 125 250 500 1000 2000 4000 800072 81 82.7 80.6 80.5 77.7 75.2 72.1 69.7 67.2

Notes:1 Outdoor sound data is measured in accordance with AHRI standard 270. 2 Measurements are expressed in terms of sound power. Do not compare these values to sound pressure values because sound pressure depends on specific environment factors which normally do not match individual applications. Sound power values are independent of the environment and therefore more accurate.3 A-weighted sound ratings filter out high and very low frequencies, to better approximate the response of "average" human ear. A-weighted measurements for Daikin units are taken in accordance with AHRI standard 270.

Model Tons Fin height in. Fin length in.DBC 6 34.64 38.07

Coil Dimensions

Page 10: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Expanded Cooling Data

10 www.daikinac.com SS-DBC6

DBC072*V/SO

utdo

or A

mbi

ent T

empe

ratu

re

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Air

flow

ID W

B59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1800

Capa

city

70,0

0770

,998

73,0

95-

69,3

7870

,370

72,4

67-

67,5

4568

,537

70,6

34-

64,3

9265

,383

67,4

80-

60,5

3761

,529

63,6

26-

57,0

1858

,010

60,1

07-

S/T

0.63

0.55

0.41

-0.

640.

560.

41-

0.67

0.59

0.44

-0.

690.

610.

46-

1.00

0.63

0.48

-1.

000.

690.

54-

Evap

dT

21.1

719

.24

15.6

4-

21.1

119

.19

15.5

8-

21.3

919

.46

15.8

6-

21.1

019

.17

15.5

6-

20.8

418

.91

15.3

1-

22.0

520

.12

16.5

1-

Pr S

uc12

212

312

6-

129

131

134

-13

613

714

0-

141

143

146

-14

714

815

1-

153

155

158

-

Pr D

is25

525

625

8-

296

297

299

-33

833

934

1-

384

385

386

-43

343

443

6-

485

486

488

-

Tota

lPow

er4,

434

4,43

04,

421

-4,

947

4,94

34,

934

-5,

520

5,51

65,

507

-6,

140

6,13

66,

127

-6,

833

6,82

96,

820

-7,

645

7,64

17,

633

-

2128

Capa

city

71,1

2272

,113

74,2

10-

70,4

9371

,485

73,5

82-

68,6

6069

,652

71,7

49-

65,5

0666

,498

68,5

95-

61,6

5262

,644

64,7

41-

58,1

3359

,125

61,2

22-

S/T

0.72

0.64

0.49

-0.

730.

640.

50-

0.75

0.67

0.52

-1.

000.

690.

55-

1.00

0.72

0.57

-1.

000.

770.

62-

Evap

dT

19.6

917

.76

14.1

6-

19.6

417

.71

14.1

1-

19.9

117

.98

14.3

8-

19.6

217

.69

14.0

9-

19.3

617

.43

13.8

3-

20.5

718

.64

15.0

4-

Pr S

uc12

412

512

9-

131

133

136

-13

813

914

2-

143

145

148

-14

915

015

3-

155

157

160

-

Pr D

is25

825

926

1-

298

300

301

-34

134

234

4-

386

387

389

-43

543

643

8-

488

489

491

-

Tota

lPow

er4,

468

4,46

44,

455

-4,

981

4,97

74,

968

-5,

554

5,55

05,

541

-6,

174

6,17

06,

161

-6,

866

6,86

26,

854

-7,

679

7,67

57,

666

-

2700

Capa

city

73,7

8174

,773

76,8

70-

73,1

5374

,144

76,2

41-

71,3

2072

,311

74,4

08-

68,1

6669

,157

71,2

54-

64,3

1265

,303

67,4

00-

60,7

9361

,784

63,8

81-

S/T

0.77

0.69

0.54

-0.

770.

690.

55-

0.80

0.72

0.57

-1.

000.

740.

59-

1.00

0.76

0.62

-1.

000.

820.

67-

Evap

dT

17.7

215

.79

12.1

9-

17.6

615

.74

12.1

3-

17.9

416

.01

12.4

1-

17.6

415

.72

12.1

1-

17.3

915

.46

11.8

6-

18.5

916

.67

13.0

6-

Pr S

uc12

913

013

3-

136

137

141

-14

214

414

7-

148

149

153

-15

315

515

8-

160

162

165

-

Pr D

is26

326

426

6-

303

304

306

-34

534

634

8-

391

392

394

-44

044

144

3-

492

493

495

-

Tota

lPow

er4,

512

4,50

84,

500

-5,

026

5,02

25,

013

-5,

599

5,59

55,

586

-6,

219

6,21

56,

206

-6,

911

6,90

76,

898

-7,

724

7,72

07,

711

-

75

1800

Capa

city

70,0

4871

,039

73,1

3676

,340

69,4

1970

,411

72,5

0875

,711

67,5

8668

,578

70,6

7573

,878

64,4

3265

,424

67,5

2170

,724

60,5

7861

,570

63,6

6766

,870

57,0

5958

,051

60,1

4863

,351

S/T

0.77

0.69

0.55

0.39

0.78

0.70

0.55

0.40

1.00

0.73

0.58

0.42

1.00

0.75

0.60

0.45

1.00

0.77

0.62

0.47

1.00

1.00

0.68

0.53

Evap

dT

25.4

123

.48

19.8

816

.15

25.3

623

.43

19.8

316

.09

25.6

323

.70

20.1

016

.37

25.3

423

.41

19.8

116

.07

25.0

823

.15

19.5

515

.82

26.2

924

.36

20.7

617

.02

Pr S

uc12

212

312

613

212

913

113

413

913

613

714

014

514

114

314

615

114

714

815

115

615

315

515

816

3

Pr D

is25

625

725

826

329

629

729

930

333

833

934

134

638

438

538

739

143

343

443

644

048

548

648

849

3

Tota

lPow

er4,

431

4,42

74,

418

4,45

74,

944

4,94

04,

931

4,97

05,

517

5,51

35,

504

5,54

36,

137

6,13

36,

124

6,16

36,

829

6,82

56,

817

6,85

67,

642

7,63

87,

629

7,66

9

2128

Capa

city

71,1

6372

,154

74,2

5177

,454

70,5

3471

,526

73,6

2376

,826

68,7

0169

,693

71,7

9074

,993

65,5

4766

,539

68,6

3671

,839

61,6

9362

,684

64,7

8267

,985

58,1

7459

,166

61,2

6364

,466

S/T

0.86

0.78

0.63

0.48

0.87

0.78

0.64

0.48

1.00

0.81

0.66

0.51

1.00

0.83

0.68

0.53

1.00

0.86

0.71

0.55

1.00

1.00

0.76

0.61

Evap

dT

23.9

322

.01

18.4

014

.67

23.8

821

.95

18.3

514

.62

24.1

522

.22

18.6

214

.89

23.8

621

.93

18.3

314

.60

23.6

021

.67

18.0

714

.34

24.8

122

.88

19.2

815

.55

Pr S

uc12

412

512

913

413

113

313

614

113

813

914

214

814

314

514

815

314

915

015

315

915

615

716

016

5

Pr D

is25

825

926

126

629

930

030

230

634

134

234

434

838

638

838

939

443

643

743

844

348

848

949

149

5

Tota

lPow

er4,

464

4,46

04,

452

4,49

14,

978

4,97

44,

965

5,00

45,

550

5,54

65,

538

5,57

76,

170

6,16

66,

158

6,19

76,

863

6,85

96,

850

6,89

07,

676

7,67

27,

663

7,70

2

2700

Capa

city

73,8

2274

,814

76,9

1180

,114

73,1

9474

,185

76,2

8279

,486

71,3

6172

,352

74,4

4977

,652

68,2

0769

,198

71,2

9574

,499

64,3

5265

,344

67,4

4170

,644

60,8

3461

,825

63,9

2267

,126

S/T

0.91

0.83

0.68

0.52

1.00

0.83

0.69

0.53

1.00

0.86

0.71

0.56

1.00

0.88

0.73

0.58

1.00

1.00

0.76

0.60

1.00

1.00

0.81

0.66

Evap

dT

21.9

620

.03

16.4

312

.70

21.9

119

.98

16.3

812

.64

22.1

820

.25

16.6

512

.91

21.8

919

.96

16.3

612

.62

21.6

319

.70

16.1

012

.37

22.8

420

.91

17.3

113

.57

Pr S

uc12

913

013

313

813

613

714

114

614

214

414

715

214

814

915

315

815

315

515

816

316

016

216

517

0

Pr D

is26

326

426

627

030

330

430

631

134

634

734

835

339

139

239

439

844

044

144

344

849

349

449

550

0

Tota

lPow

er4,

509

4,50

54,

496

4,53

65,

022

5,01

85,

010

5,04

95,

595

5,59

15,

582

5,62

26,

215

6,21

16,

202

6,24

26,

908

6,90

46,

895

6,93

47,

721

7,71

77,

708

7,74

7

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ctio

n ac

cess

fitt

ings

.A

mps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

6 - 1

9 °F

@ th

e liq

uid

acce

ss fi

ttin

g co

nnec

tion

ARI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

- 12

°F @

the

com

pres

sor s

uctio

n ac

cess

fitt

ing

conn

ectio

n.

Page 11: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Expanded Cooling Data

SS-DBC6 www.daikinac.com 11

DBC072*V/SO

utdo

or A

mbi

ent T

empe

ratu

re

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Air

flow

ID W

B59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1800

Capa

city

70,4

1171

,403

73,5

0076

,703

69,7

8370

,775

72,8

7276

,075

67,9

5068

,941

71,0

3974

,242

64,7

9665

,788

67,8

8571

,088

60,9

4261

,933

64,0

3067

,234

57,4

2358

,415

60,5

1263

,715

S/T

0.91

0.83

0.68

0.53

1.00

0.83

0.69

0.53

1.00

0.86

0.71

0.56

1.00

0.88

0.74

0.58

1.00

1.00

0.76

0.61

1.00

1.00

0.82

0.66

Evap

dT

29.6

827

.75

24.1

520

.42

29.6

327

.70

24.1

020

.36

29.9

027

.97

24.3

720

.64

29.6

127

.68

24.0

820

.34

29.3

527

.42

23.8

220

.09

30.5

628

.63

25.0

321

.29

Pr S

uc12

212

412

713

213

013

113

414

013

613

814

114

614

214

314

615

214

714

915

215

715

415

515

816

4

Pr D

is25

625

725

926

329

629

729

930

433

934

034

234

638

438

538

739

243

343

443

644

148

648

748

949

3

Tota

lPow

er4,

433

4,42

94,

421

4,46

04,

947

4,94

34,

934

4,97

35,

519

5,51

55,

507

5,54

66,

139

6,13

56,

127

6,16

66,

832

6,82

86,

819

6,85

97,

645

7,64

17,

632

7,67

1

2128

Capa

city

71,5

2672

,518

74,6

1577

,818

70,8

9871

,889

73,9

8777

,190

69,0

6570

,056

72,1

5375

,357

65,9

1166

,903

69,0

0072

,203

62,0

5763

,048

65,1

4568

,348

58,5

3859

,529

61,6

2664

,830

S/T

1.00

0.91

0.77

0.61

1.00

0.92

0.77

0.62

1.00

0.95

0.80

0.64

1.00

1.00

0.82

0.67

1.00

1.00

0.84

0.69

1.00

1.00

0.90

0.75

Evap

dT

28.2

026

.28

22.6

718

.94

28.1

526

.22

22.6

218

.89

28.4

226

.49

22.8

919

.16

28.1

326

.20

22.6

018

.87

27.8

725

.95

22.3

418

.61

29.0

827

.15

23.5

519

.82

Pr S

uc12

412

612

913

413

213

313

614

213

814

014

314

814

414

514

915

414

915

115

415

915

615

816

116

6

Pr D

is25

926

026

226

629

930

030

230

634

134

234

434

938

738

839

039

443

643

743

944

348

849

049

149

6

Tota

lPow

er4,

467

4,46

34,

454

4,49

34,

980

4,97

64,

967

5,00

75,

553

5,54

95,

540

5,58

06,

173

6,16

96,

160

6,20

06,

866

6,86

26,

853

6,89

27,

678

7,67

47,

666

7,70

5

2700

Capa

city

74,1

8675

,177

77,2

7480

,478

73,5

5774

,549

76,6

4679

,849

71,7

2472

,716

74,8

1378

,016

68,5

7069

,562

71,6

5974

,862

64,7

1665

,708

67,8

0571

,008

61,1

9762

,189

64,2

8667

,489

S/T

1.00

0.96

0.81

0.66

1.00

0.97

0.82

0.67

1.00

0.99

0.85

0.69

1.00

1.00

0.87

0.71

1.00

1.00

0.89

0.74

1.00

1.00

0.95

0.79

Evap

dT

26.2

324

.30

20.7

016

.97

26.1

824

.25

20.6

516

.91

26.4

524

.52

20.9

217

.19

26.1

624

.23

20.6

316

.89

25.9

023

.97

20.3

716

.64

27.1

125

.18

21.5

817

.84

Pr S

uc12

913

113

413

913

713

814

114

614

314

514

815

314

915

015

315

815

415

515

916

416

116

216

517

0

Pr D

is26

326

426

627

130

430

530

731

134

634

734

935

339

239

339

439

944

144

244

444

849

349

449

650

0

Tota

lPow

er4,

512

4,50

84,

499

4,53

85,

025

5,02

15,

012

5,05

25,

598

5,59

45,

585

5,62

46,

218

6,21

46,

205

6,24

46,

911

6,90

76,

898

6,93

77,

723

7,71

97,

711

7,75

0

85

1800

Capa

city

71,5

9472

,586

74,6

8377

,886

70,9

6671

,957

74,0

5477

,258

69,1

3370

,124

72,2

2175

,425

65,9

7966

,970

69,0

6872

,271

62,1

2563

,116

65,2

1368

,416

58,6

0659

,597

61,6

9464

,898

S/T

1.00

0.94

0.79

0.64

1.00

0.94

0.80

0.64

1.00

1.00

0.82

0.67

1.00

1.00

0.85

0.69

1.00

1.00

0.87

0.71

1.00

1.00

1.00

0.77

Evap

dT

33.4

731

.54

27.9

424

.20

33.4

131

.48

27.8

824

.15

33.6

831

.76

28.1

524

.42

33.3

931

.46

27.8

624

.13

33.1

431

.21

27.6

123

.87

34.3

432

.41

28.8

125

.08

Pr S

uc12

412

612

913

413

213

313

614

113

814

014

314

814

414

514

815

314

915

015

415

915

615

716

016

5

Pr D

is25

725

826

026

529

829

930

030

534

034

134

334

738

538

738

839

343

543

643

744

248

748

849

049

4

Tota

lPow

er4,

443

4,43

94,

430

4,47

04,

956

4,95

24,

944

4,98

35,

529

5,52

55,

516

5,55

66,

149

6,14

56,

136

6,17

66,

842

6,83

86,

829

6,86

87,

655

7,65

17,

642

7,68

1

2128

Capa

city

72,7

0973

,701

75,7

9879

,001

72,0

8173

,072

75,1

6978

,373

70,2

4871

,239

73,3

3676

,539

67,0

9468

,085

70,1

8273

,386

63,2

3964

,231

66,3

2869

,531

59,7

2160

,712

62,8

0966

,013

S/T

1.00

1.00

0.87

0.72

1.00

1.00

0.88

0.73

1.00

1.00

0.91

0.75

1.00

1.00

0.93

0.78

1.00

1.00

0.95

0.80

1.00

01.

000

1.00

00.

855

Evap

dT

31.9

930

.06

26.4

622

.73

31.9

430

.01

26.4

122

.68

32.2

130

.28

26.6

822

.95

31.9

229

.99

26.3

922

.66

31.6

629

.73

26.1

322

.40

32.8

730

.94

27.3

423

.61

Pr S

uc12

612

813

113

613

413

513

814

414

014

214

515

014

614

715

015

615

115

315

616

115

815

916

216

8

Pr D

is26

026

126

326

730

030

130

330

834

334

434

535

038

838

939

139

643

743

844

044

549

049

149

349

7

Tota

lPow

er4,

477

4,47

34,

464

4,50

34,

990

4,98

64,

977

5,01

75,

563

5,55

95,

550

5,58

96,

183

6,17

96,

170

6,20

96,

876

6,87

26,

863

6,90

27,

688

7,68

47,

675

7,71

5

2700

Capa

city

75,3

6976

,360

78,4

5781

,660

74,7

4075

,732

77,8

2981

, 032

72,9

0773

,899

75,9

9679

,199

69,7

5370

,745

72,8

4276

,045

65,8

9966

,890

68,9

8772

,191

62,3

8063

,372

65,4

6968

,672

S/T

1.00

1.00

0.92

0.77

1.00

1.00

0.93

0.78

1.00

1.00

0.96

0.80

1.00

1.00

0.98

0.82

1.00

1.00

1.00

0.85

1.00

1.00

1.00

0.90

Evap

dT

30.0

228

.09

24.4

920

.75

29.9

628

.03

24.4

320

.70

30.2

328

.31

24.7

020

.97

29.9

428

.01

24.4

120

.68

29.6

927

.76

24.1

620

.42

30.8

928

.96

25.3

621

.63

Pr S

uc13

113

213

614

113

814

014

314

814

514

614

915

515

015

215

516

015

615

716

016

616

216

416

717

2

Pr D

is26

526

626

727

230

530

630

831

234

734

835

035

539

339

439

640

044

244

344

544

949

449

549

750

2

Tota

lPow

er4,

522

4,51

84,

509

4,54

85,

035

5,03

15,

022

5,06

15,

608

5,60

45,

595

5,63

46,

228

6,22

46,

215

6,25

46,

920

6,91

66,

908

6,94

77,

733

7,72

97,

720

7,76

0

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s A

HRI

(TVA

) con

ditio

nskW

= T

otal

sys

tem

pow

er

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ctio

n ac

cess

fitt

ings

.A

mps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

6 - 1

9 °F

@ th

e liq

uid

acce

ss fi

ttin

g co

nnec

tion

ARI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

- 12

°F @

the

com

pres

sor s

uctio

n ac

cess

fitt

ing

conn

ectio

n.

Page 12: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Electrical Heater Data

12 www.daikinac.com SS-DBC6

Electric Heaters

Mo

del

#

Min

Air

flo

w

Max

Air

flo

w

EH*B

-*S0

5

EH*B

-*S1

0

EH*B

-*S1

5

EH*B

-*S1

8

EH*B

-*S2

0

EH*B

-*S3

0

DBC072* 1950 2700 X X X X X X

Page 13: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Airflow

SS-DBC6 www.daikinac.com 13

DBC072*V Standard Belt-Drive Downshot

ESP, In H2O

TURNS OPEN0 1 2 3 4 5

CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.1 2898 1315 1.90 2754 1245 1.62 2612 1175 1.37 2498 1110 1.16 2366 1040 0.97 2227 970 0.790.2 2838 1315 1.85 2690 1245 1.57 2544 1175 1.33 2423 1110 1.12 2283 1040 0.93 2137 970 0.750.3 2777 1315 1.81 2624 1245 1.53 2472 1175 1.28 2345 1110 1.08 2198 1040 0.89 2041 970 0.710.4 2714 1315 1.76 2557 1245 1.48 2399 1175 1.24 2265 1110 1.04 2108 1040 0.84 1941 970 0.670.5 2649 1315 1.71 2486 1245 1.43 2322 1175 1.19 2180 1110 0.99 2013 1040 0.80 1833 970 0.630.6 2583 1315 1.66 2414 1245 1.39 2242 1175 1.15 2092 1110 0.95 1913 1040 0.76 - - -0.7 2514 1315 1.61 2339 1245 1.34 2159 1175 1.10 1999 1110 0.90 1805 1040 0.71 - - -0.8 2443 1315 1.56 2260 1245 1.29 2072 1175 1.05 1900 1110 0.86 - - - - - -

DBC072*S High-Static Belt-Drive Downshot

ESP, In H2O

TURNS OPEN0 1 2 3 4 5

CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.6 - - - - - - 2630 1385 1.88 2492 1315 1.60 2337 1245 1.34 2179 1175 1.110.7 - - - - - - 2569 1385 1.83 2425 1315 1.55 2264 1245 1.29 2098 1175 1.070.8 - - - - - - 2507 1385 1.78 2357 1315 1.50 2188 1245 1.25 2013 1175 1.020.9 - - - - - - 2442 1385 1.73 2285 1315 1.45 2109 1245 1.20 1924 1175 0.971.0 - - - 2514 1455 1.96 2375 1385 1.68 2211 1315 1.40 2026 1245 1.15 1828 1175 0.931.1 - - - 2452 1455 1.91 2306 1385 1.62 2134 1315 1.35 1938 1245 1.10 - - -1.2 - - - 2387 1455 1.86 2234 1385 1.57 2053 1315 1.30 1846 1245 1.05 - - -1.3 - - - 2321 1455 1.80 2159 1385 1.52 1968 1315 1.25 - - - - - -1.4 - - - 2251 1455 1.75 2080 1385 1.46 1878 1315 1.19 - - - - - -1.5 2346 1525 2.00 2179 1455 1.69 1998 1385 1.41 - - - - - - - - -1.6 2280 1525 1.94 2104 1455 1.63 1911 1385 1.35 - - - - - - - - -1.7 2211 1525 1.88 2026 1455 1.57 1819 1385 1.29 - - - - - - - - -1.8 2140 1525 1.82 1943 1455 1.51 - - - - - - - - - - - -

1 To operate below 0.6" H2O external static pressure, motor and blower sheave must be changed to VL34 and AK59 respectively, or equivalents.

DBC072*V Standard Belt-Drive Horizontal

ESP, In H2O

TURNS OPEN0 1 2 3 4 5

CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.1 2840 1315 1.87 2701 1245 1.59 2563 1175 1.35 2437 1110 1.14 2296 1040 0.94 2151 970 0.770.2 2782 1315 1.82 2638 1245 1.55 2496 1175 1.30 2365 1110 1.10 2217 1040 0.90 2064 970 0.730.3 2722 1315 1.77 2574 1245 1.50 2427 1175 1.26 2289 1110 1.06 2134 1040 0.86 1973 970 0.690.4 2661 1315 1.73 2508 1245 1.46 2355 1175 1.22 2211 1110 1.01 2048 1040 0.82 1876 970 0.650.5 2598 1315 1.68 2440 1245 1.41 2280 1175 1.17 2129 1110 0.97 1956 1040 0.78 - - -0.6 2533 1315 1.63 2369 1245 1.36 2202 1175 1.13 2044 1110 0.93 1860 1040 0.74 - - -0.7 2466 1315 1.58 2296 1245 1.31 2121 1175 1.08 1953 1110 0.88 - - - - - -0.8 2397 1315 1.53 2219 1245 1.27 2036 1175 1.03 1858 1110 0.84 - - - - - -

DBC072*S High-Static Belt-Drive Horizontal

ESP, In H2O

TURNS OPEN0 1 2 3 4 5

CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP0.6 - - - - - - 2655 1385 1.90 2520 1315 1.62 2369 1245 1.36 2213 1175 1.130.7 - - - - - - 2594 1385 1.85 2454 1315 1.57 2296 1245 1.31 2132 1175 1.090.8 - - - - - - 2531 1385 1.80 2385 1315 1.52 2219 1245 1.27 2046 1175 1.040.9 - - - - - - 2466 1385 1.75 2313 1315 1.47 2140 1245 1.22 1956 1175 0.991.0 - - - 2552 1455 2.00 2399 1385 1.70 2239 1315 1.42 2056 1245 1.17 1860 1175 0.941.1 - - - 2489 1455 1.94 2330 1385 1.64 2161 1315 1.37 1968 1245 1.12 - - -1.2 - - - 2424 1455 1.89 2258 1385 1.59 2080 1315 1.32 1875 1245 1.06 - - -1.3 - - - 2357 1455 1.83 2183 1385 1.53 1995 1315 1.26 - - - - - -1.4 - - - 2287 1455 1.77 2104 1385 1.48 1904 1315 1.21 - - - - - -1.5 - - - 2215 1455 1.72 2022 1385 1.42 1808 1315 1.15 - - - - - -1.6 2328 1525 1.98 2139 1455 1.66 1935 1385 1.36 - - - - - - - - -1.7 2259 1525 1.92 2060 1455 1.60 1842 1385 1.30 - - - - - - - - -1.8 2186 1525 1.86 1976 1455 1.54 - - - - - - - - - - - -

1 To operate below 0.6" H2O external static pressure, motor and blower sheave must be changed to VL34 and AK59 respectively, or equivalents.

DBC072*V – Standard / High

Page 14: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

14 www.daikinac.com SS-DBC6

Static Pressure

3-6 TONS

DOWNFLOW ECONOMIZER PRESSURE DROP

Cabinet CFM SP in.wg.

6 Ton1800 .13"2400 .22"3000 .33"

3-6 TONS

HORIZONTAL ECONOMIZER PRESSURE DROP

Cabinet CFM SP in.wg.

6 Ton1800 .24"2400 .41"3000 .61"

Page 15: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

SS-DBC6 www.daikinac.com 15

Electrical Data

Model Number

Electrical Rating

Compressor Outdoor Fan Motor

Indoor Fan Motor Optional Electric Heat

Optional Powered

Convenience Outlet

Optional Power

ExhaustPower Supply

QTY RLA LRA QTY HP FLA TYPE HP FLA PART # KW* FLA FLA FLA MCA MOP

DBC0723S 208/230/3/60 1 17.56 136 1 0.33 22-Speed

Belt-Drive High-Static

2 6

- - - - - 30.0/30.0 45/45- - - 9.6/8.7 - 39.6/38.7 50/50- - - - 1.7/1.5 31.7/31.5 45/45- - - 9.6/8.7 1.7/1.5 41.3/40.2 50/50

EH*B-3S05 3.76/5.00 10.4/12.0

- - 30.0/30.0 45/459.6/8.7 - 39.6/38.7 50/50

- 1.7/1.5 31.7/31.5 45/459.6/8.7 1.7/1.5 41.3/40.2 50/50

EH*B-3S10 7.51/10.0 20.8/24.1

- - 33.6/37.6 45/459.6/8.7 - 45.6/48.4 50/50

- 1.7/1.5 35.7/39.4 45/459.6/8.7 1.7/1.5 47.7/50.3 50/60

EH*B-3S15 11.3/15.0 31.3/36.1

- - 46.6/52.6 50/609.6/8.7 - 58.6/63.5 60/70

- 1.7/1.5 48.7/54.5 50/609.6/8.7 1.7/1.5 60.7/65.4 70/70

EH*B-3S18 13.5/18.0 37.5/43.3

- - 54.4/61.6 60/709.6/8.7 - 66.4/72.5 70/80

- 1.7/1.5 56.5/63.5 60/709.6/8.7 1.7/1.5 68.5/74.4 70/80

EH*B-3S20 15.0/19.9 41.5/47.9

- - 59.4/67.3 60/709.6/8.7 - 71.4/78.2 80/80

- 1.7/1.5 61.5/69.2 70/709.6/8.7 1.7/1.5 73.5/80.1 80/90

EH*B-3S30 21.6/28.8 60.0/69.3

- - 82.6/94.1 90/1009.6/8.7 - 94.6/105 100/110

- 1.7/1.5 84.7/96.0 90/1009.6/8.7 1.7/1.5 96.7/107 100/110

DBC0723V 208/230/3/60 1 17.56 136 1 0.33 2

2-Speed Belt-Drive Standard

Static

2 6

- - - - - 30.0/30.0 45/45- - - 9.6/8.7 - 39.6/38.7 50/50- - - - 1.7/1.5 31.7/31.5 45/45- - - 9.6/8.7 1.7/1.5 41.3/40.2 50/50

EH*B-3S05 3.76/5.00 10.4/12.0

- - 30.0/30.0 45/459.6/8.7 - 39.6/38.7 50/50

- 1.7/1.5 31.7/31.5 45/459.6/8.7 1.7/1.5 41.3/40.2 50/50

EH*B-3S10 7.51/10.0 20.8/24.1

- - 33.6/37.6 45/459.6/8.7 - 45.6/48.4 50/50

- 1.7/1.5 35.7/39.4 45/459.6/8.7 1.7/1.5 47.7/50.3 50/60

EH*B-3S15 11.3/15.0 31.3/36.1

- - 46.6/52.6 50/609.6/8.7 - 58.6/63.5 60/70

- 1.7/1.5 48.7/54.5 50/609.6/8.7 1.7/1.5 60.7/65.4 70/70

EH*B-3S18 13.5/18.0 37.5/43.3

- - 54.4/61.6 60/709.6/8.7 - 66.4/72.5 70/80

- 1.7/1.5 56.5/63.5 60/709.6/8.7 1.7/1.5 68.5/74.4 70/80

EH*B-3S20 15.0/19.9 41.5/47.9

- - 59.4/67.3 60/709.6/8.7 - 71.4/78.2 80/80

- 1.7/1.5 61.5/69.2 70/709.6/8.7 1.7/1.5 73.5/80.1 80/90

EH*B-3S30 21.6/28.8 60.0/69.3

- - 82.6/94.1 90/1009.6/8.7 - 94.6/105 100/110

- 1.7/1.5 84.7/96.0 90/1009.6/8.7 1.7/1.5 96.7/107 100/110

Page 16: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

16 www.daikinac.com SS-DBC6

Electrical Data

Model Number

Electrical Rating

Compressor Outdoor Fan Motor

Indoor Fan Motor Optional Electric Heat

Optional Powered

Convenience Outlet

Optional Power

ExhaustPower Supply

QTY RLA LRA QTY HP FLA TYPE HP FLA PART # KW* FLA FLA FLA MCA MOP

DBC0724S 460/3/60 1 8.46 66.1 1 0.33 0.852-Speed

Belt-Drive High-Static

2 2.9

- - - - - 14.3 20- - - 4.3 - 18.6 25- - - - 0.5 14.8 20- - - 4.3 0.5 19.1 25

EH*B-4S05 5 6.01

- - 14.3 204.3 - 18.6 25

- 0.5 14.8 204.3 0.5 19.1 25

EH*B-4S10 10 12

- - 18.7 204.3 - 24 25

- 0.5 19.3 204.3 0.5 24.7 25

EH*B-4S15 15 18

- - 26.2 304.3 - 31.6 35

- 0.5 26.8 304.3 0.5 32.2 35

EH*B-4S18 18 21.7

- - 30.7 354.3 - 36.1 40

- 0.5 31.3 354.3 0.5 36.7 40

EH*B-4S20 20 24.1

- - 33.7 354.3 - 39.1 40

- 0.5 34.3 354.3 0.5 39.7 40

EH*B-4S30 30 36.1

- - 48.7 504.3 - 54.1 60

- 0.5 49.4 504.3 0.5 54.7 60

DBC0724V 460/3/60 1 8.46 66.1 1 0.33 0.85

2-Speed Belt-Drive Standard

Static

2 2.9

- - - - - 14.3 20- - - 4.3 - 18.6 25- - - - 0.5 14.8 20- - - 4.3 0.5 19.1 25

EH*B-4S05 5 6.01

- - 14.3 204.3 - 18.6 25

- 0.5 14.8 204.3 0.5 19.1 25

EH*B-4S10 10 12

- - 18.7 204.3 - 24 25

- 0.5 19.3 204.3 0.5 24.7 25

EH*B-4S15 15 18

- - 26.2 304.3 - 31.6 35

- 0.5 26.8 304.3 0.5 32.2 35

EH*B-4S18 18 21.7

- - 30.7 354.3 - 36.1 40

- 0.5 31.3 354.3 0.5 36.7 40

EH*B-4S20 20 24.1

- - 33.7 354.3 - 39.1 40

- 0.5 34.3 354.3 0.5 39.7 40

EH*B-4S30 30 36.1

- - 48.7 504.3 - 54.1 60

- 0.5 49.4 504.3 0.5 54.7 60

Page 17: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

SS-DBC6 www.daikinac.com 17

Model Number

Electrical Rating

Compressor Outdoor Fan Motor

Indoor Fan Motor Optional Electric Heat

Optional Powered

Convenience Outlet

Optional Power

ExhaustPower Supply

QTY RLA LRA QTY HP FLA TYPE HP FLA PART # KW* FLA FLA FLA MCA MOP

DBC0727S 575/3/60 1 6.35 55.3 1 0.33 0.672-Speed

Belt-Drive High-Static

2 2.4

- - - - - 11 15- - - 3.5 - 14.5 20- - - - 0.6 11.6 15- - - 3.5 0.6 15.1 20

EH*B-7S05 5 4.81

- - 11 153.5 - 14.5 20

- 0.6 11.6 153.5 0.6 15.1 20

EH*B-7S10 10 9.62

- - 15 203.5 - 19.4 20

- 0.6 15.8 203.5 0.6 20.2 25

EH*B-7S15 15 14.4

- - 21 253.5 - 25.4 30

- 0.6 21.8 253.5 0.6 26.2 30

EH*B-7S18 18 17.3

- - 24.7 253.5 - 29 30

- 0.6 25.4 303.5 0.6 29.8 30

EH*B-7S20 20 19.2

- - 27.1 303.5 - 31.4 35

- 0.6 27.8 303.5 0.6 32.2 35

EH*B-7S30 30 28.9

- - 39.1 403.5 - 43.5 45

- 0.6 39.8 403.5 0.6 44.2 45

DBC0727V 575/3/60 1 6.35 55.3 1 0.33 0.67

2-Speed Belt-Drive Standard

Static

2 2.4

- - - - - 11 15- - - 3.5 - 14.5 20- - - - 0.6 11.6 15- - - 3.5 0.6 15.1 20

EH*B-7S05 5 4.81

- - 11 153.5 - 14.5 20

- 0.6 11.6 153.5 0.6 15.1 20

EH*B-7S10 10 9.62

- - 15 203.5 - 19.4 20

- 0.6 15.8 203.5 0.6 20.2 25

EH*B-7S15 15 14.4

- - 21 253.5 - 25.4 30

- 0.6 21.8 253.5 0.6 26.2 30

EH*B-7S18 18 17.3

- - 24.7 253.5 - 29 30

- 0.6 25.4 303.5 0.6 29.8 30

EH*B-7S20 20 19.2

- - 27.1 303.5 - 31.4 35

- 0.6 27.8 303.5 0.6 32.2 35

EH*B-7S30 30 28.9

- - 39.1 403.5 - 43.5 45

- 0.6 39.8 403.5 0.6 44.2 45

Electrical Data

Page 18: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Wire Diagram

18 www.daikinac.com SS-DBC6

Wiri

ng i

s su

bjec

t to

cha

nge.

Alw

ays

refe

r to

the

wiri

ng d

iagr

am o

n th

e un

it fo

r th

e m

ost

up-t

o-da

te w

iring

.⚠

War

ning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, o

r dea

th.⚡

3-Phase Diagram

CC

H

BK

GR

RD

BK

BK

CH

R

CH

R

24

68

1 2 3 4 5

6A 7 8

R

XMFR

- R

XMFR

- C C

SP

EE

D U

PE

BTD

RG

CO

M NC

NO M1

M2

3A

121110987654321

121110987654321

4321

4321987654321

BL

BL

654321

654321

RD

CC

POW

ER A

ND

CON

TRO

LS W

IRIN

G D

IAG

RAM

DB

C072

, 3 P

HAS

E, 2

-SPD

BEL

T D

RIVE

CH

S

THE

RM

OS

TAT+

+

6A

6B

6B

PLM

PLF

PU

YL

TB1

PLM

PLF

GR

YL

PU

GR

WH

2

TB1

W2

Y1

OY

2S

2R

W1

CS

1G

DH

T1T2

T3T4

T5

GY

YL

WH

PU

TB2

BA

CD BL

CC

A1

A2

BL

WIR

E CO

DE

NO

TES

BLA

CK

BLU

EB

LUE

WIT

H P

INK

STR

IPE

BR

OW

NG

RE

ENG

RA

YO

RAN

GE

PIN

KP

UR

PLE

RED

TAN

WH

ITE

YE

LLO

WY

ELL

OW

WIT

H P

INK

STR

IPE

BK

BL

BL/

PK

BR

GR

GY

OR

PK

PU

RD

TN WH

YL

YL/

PK

HIG

H V

OLT

AG

ELO

W V

OLT

AG

EO

PTI

ON

AL

HIG

H V

OLT

AG

EO

PTI

ON

AL

LOW

VO

LTA

GE

CH

AS

SIS

GR

OU

ND

FIEL

DW

IRIN

G

FACT

ORY

WIR

ING

HIG

H V

OLT

AG

ELO

W V

OLT

AG

E

EA

RTH

GR

OU

ND

CO

MPO

NENT

LEG

END

RD

RD

BL

GR

YL

WH

PU

BL

YL

EH

KP

LF

BR

WH

BR

3

PK

PK

YL

HP

S

LPS

PLF

PLM

BL

BL

YL

YL

BL/

PK

YL/

PK

YL/

PK

BL/

PK

YL

BK

BK

BK

BK

YL

0140

L071

97-A

GY

WH

BK

L1 L2

T3

CO

MP

L3

T1 T2

BK

L3L1

PB

L1

GN

D

L2L3

LIN

EV

OLT

AG

E

BK

RD

OR

TR1

CB

GR

BK

RD OR

RD

L2

4

208-

230/

460/

575V

/3P

H/6

0Hz

FB1

5B

KR

DO

R

CO

M

F1F1F1

BK

OR

GRM 3~

YL

BK

RD

BKBK

RD

OR

BK

RD

OR

FB2

F2 F2 F2

5

RD

RD

3

CH

R1

0P

KP

KR

DR

D

BL

BL

BC

BLO

WE

R C

ON

TAC

TOR

CB

CIR

CU

IT B

RE

AK

ER

CC

CO

MPR

ES

SO

R C

ON

TAC

TOR

CC

HC

RAN

KCA

SE

HE

ATE

RC

CP

CO

MPR

ES

SO

R/C

OIL

PR

OTE

CTI

ON

CH

RC

RAN

KA

SE

HE

ATE

R R

ELA

YC

HS

CR

ANKC

AS

E H

EA

TER

SW

ITC

HC

MC

ON

DEN

SER

MO

TOR

CO

MP

CO

MPR

ES

SO

RE

BTD

RE

LEC

TRO

NIC

BLO

WE

R T

IME

DE

LAY

EC

ON

EC

ON

OM

IZER

EH

KE

LEC

TRIC

HE

ATE

R K

ITE

SE

ME

RG

ENC

Y S

HU

TDO

WN

FBFU

SE

BLO

CK

FCFA

N C

AP

AC

ITO

RFP

SFR

EE

ZE P

RO

TEC

TIO

N S

WIT

CH

GN

DE

QU

IPM

EN

T G

RO

UN

DH

PS

HIG

H P

RE

SSU

RE

SW

ITC

HLP

SLO

W P

RE

SSU

RE

SW

ITC

H

MA

TM

IXE

D A

IR T

EM

P. S

EN

SO

RP

BP

OW

ER

DIS

TRIB

UTI

ON

BLO

CK

PLF

FEM

ALE

PLU

G/C

ON

NEC

TOR

PLM

MA

LE P

LUG

/CO

NN

ECTO

RTB

TER

MIN

AL

BLO

CK

TRTR

AN

SFO

RM

ER

RE

PLA

CE

ME

NT

WIR

E M

US

T B

E S

AM

E S

IZE

AN

D T

YP

E O

F IN

SU

LATI

ON

AS

OR

IGIN

AL

(AT

LEA

ST 1

05°

C).

USE

CO

PP

ER

CO

ND

UC

TOR

SO

NLY

. US

E N

.E.C

. CLA

SS 2

WIR

E F

OR

ALL

LO

WV

OLT

AG

E F

IELD

CO

NN

EC

TIO

NS

.

IF O

PTIO

NA

L E

CO

NO

MIZ

ER

IS IN

STA

LLE

DR

EM

OV

E E

CO

N P

LM J

UM

PE

R A

ND

PLU

G IN

NE

W H

AR

NE

SS

FR

OM

EC

ON

OM

IZE

R K

IT

IF O

PTIO

NA

L E

LEC

TRIC

HE

AT

IS IN

STA

LLE

DP

LUG

IN N

EW

HA

RN

ES

S F

RO

M E

LEC

TRIC

HE

ATE

R K

IT. F

OR

TW

O S

TAG

E H

EA

T, R

EM

OV

EJU

MPE

R.

TR1

PR

IMA

RY

(HIG

H V

OLT

AG

E)

CO

NN

EC

TIO

NS

: O

RA

NG

E W

IRE

CO

NN

EC

TED

TO 2

40/4

60/5

75V

TAP

AT

THE

FA

CTO

RY

AN

DB

LAC

K W

IRE

TO

CO

M T

ER

MIN

AL. F

OR

208

VS

UP

PLY

PO

WE

R, M

OV

E O

RA

NG

E W

IRE

FR

OM

240V

TA

P T

O T

HE

208

V T

AP.

FUS

E B

LOC

KS

1, 2

, & 3

AR

E O

PTIO

NA

L

IF O

PTIO

NA

L S

AFE

TY E

QU

IPM

EN

T S

UC

H A

S A

PH

ASE

MO

NIT

OR

, FLO

AT

SW

ITC

H O

R S

MO

KE

DE

TEC

TOR

IS IN

STA

LLE

D, U

NP

LUG

JU

MPE

RP

LUG

AN

D P

LUG

IN S

AFE

TY D

EV

ICE

. IF

MU

LTIP

LES

AFE

TIE

S A

RE

INS

TALL

ED

, PLU

G IN

TH

EA

DD

ITIO

NA

L D

EV

ICE

S IN

SE

RIE

S. P

LUG

INJU

MPE

R P

LUG

AT

THE

LAS

T S

AFE

TY D

EV

ICE

INS

TALL

ED

.

IF A

TH

IRD

PA

RTY

SA

FETY

DE

VIC

E IS

FIE

LDIN

STA

LLE

D, C

UT

THE

RE

D W

IRE

ON

TH

E J

UM

PE

RP

LUG

AN

D W

IRE

A N

OR

MA

LLY

CLO

SE

D D

RY

CO

NTA

CT

IN S

ER

IES

WIT

H T

HE

CU

T W

IRE

.

GR

AY

WIR

E IS

A 2

4 V

AC

ALA

RM

OU

TPU

T FR

OM

OP

TIO

NA

L E

CO

NO

MIZ

ER

CO

NTR

OL

MO

DU

LE.

RE

MO

VE

JU

MP

ER

WIR

E IF

OP

TIO

NA

LFR

EE

ZES

TAT

IS IN

STA

LLE

D.

CH

R, C

CH

, CH

S A

ND

ALL

ASS

OC

IATE

D W

IRIN

GA

RE

OP

TIO

NAL

.

FOR

DE

TAIL

ED

INTE

RN

AL

WIR

ING

AN

DTE

RM

INAT

ION

, RE

FER

TO

TH

E M

OTO

R'S

NA

ME

PLA

TE.

BL

PK

THER

MO

STAT

FIE

LDW

IRIN

G++

1 S

TAG

E C

OO

LIN

G/H

EA

TIN

G2

STA

GE

CO

OLI

NG

/HE

ATI

NG

TB1

TSTA

T

W G R Y C O

WH

GR

PK

YL

BL

OR

W1

W2 G R Y1

Y2 C O

TB1

TSTA

T

W1

G R Y1

C O

WH

GR

PK

YL

BL

OR

W1

W2 G R Y1

Y2 C O

BR

W2

PU

Y2

PK

BL

7

ES

EC

ON

FPS

BK

BK

8

RD

GR

PK

WH

CC

P

LOW

SP

EE

D

HIG

H S

PE

EDGR

BK

/12

BK

/11

BK

/13

M 3~

BM

BC

2

L1

T3T2T1

L3L2L1

T3T2T1

L3L2W

H

BL

OR

BK

RD YL

WH

BL

OR

BK

RD

OR

RD

RDPKBL

CS

V1

V2

PK

PU

YL

R1

R2

t = 1

80s

Y1

Y2

TON

BL

YL

YL

BL BL

PK

GR

BR

21

0Y

L

BR

11

0

BR

22

4

BR

23

4

BR

14

2

BR

14

3B

C1

A1

A2

BR

BC

2A

1A

2B

K

GR

BL

BL

BL

BL

GY

YL

GY

BL

YL

GR

BL

YL

WH

GR

BL

RD

PK

YL

PU

WH

9

9

9

BC

1

PU

WH

YL

BL

BL

PU

BL

RD

FCC

M

GR

BR

BK

PUBR

PUBK

PU

BK

PLF

PLM

BK

PU21

M 1~

21

BK

RD

OR

CM

MA

TP

LF

BK

BK

10

10

21

Page 19: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Dimensional Data

SS-DBC6 www.daikinac.com 19

Dimensions — 6 Tons

��

.99DOZep{�{�Oe�{Ze$DO(e)O({

*+,-/

,+*-/

01+0-2

2,+3-4

*+*-05

4,+1-05

,+0-2

4+0-2

67887:;<=>?;7@;AB=8;

CEF=B

8GEA;

HAE6

I7HF8=7B

>:67JJ

@7E;

8GEA

8G>;

6FJ>

A8=I=8=>J

E>8AEB

00K;L;2*K

JAMMIN

02K;L;0,K

GPQRSPTUVW;CRXY[VQ\]

<]QURYVW;CRXY[VQ\]

B78>̂;E]_]Q;UP;=7C+,̀/2;RTYWab]b;RT;U[];WRU]QVUaQ];cVYd;_PQ;RTXUVWWRT\;[PQRSPTUVW;baYU;YPf]QXg;

hijklmnoqrstu

ruvu

hiwklmjqrsxyxz|u

l

}yxz~}

syxz|

������

~�ur�r~su

������

nnqh�hlq

Model Size DIM “A”

6 Ton AC 43½

Page 20: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

20 www.daikinac.com SS-DBC6

Electrical Connections

Unit ClearancesService ClearanceAllow for recommended service clearances as shown in figure to the right. In situations that have multiple units, a 36" minimum clearance is required between the condenser coils. A clearance of 48" is recommended on all sides of the unit to allow service access and to ensure proper ventilation and condenser airflow. The top of the unit should be unobstructed. Provide a roof walkway along the sides of the unit for service and access to controls and components. Contact your Daikin sales representative for service requirements less than those recommended.

CONTROL BOX

GROUND LUG

NOTE: CHECK TRANSFORMER TO MATCH THECORRECT VOLTAGE TAP WITH LINE VOLTAGE

24" MIN. 24" MIN.

36” MIN.

POWER AND LOW VOLTAGE BLOCK CONNECTIONS

LOW VOLTAGE BLOCK

CONTROL BOX

Page 21: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

SS-DBC6 www.daikinac.com 21

Unit LocationThe structural engineer must verify that the roof has adequate support and ability to minimize deflection. Take extreme caution when using on a wooden roof structure. Unit condenser coils should be in a location that avoids any heated exhaust air.

Allow sufficient space around the unit for maintenance/service clearance. Consult your Daikin sales representative if available clearances do not meet minimum recommendations.

Where code considerations, such as the NEC, require extended clearances, these take precedence.

Provisions for forks have been included in the unit base frame. No other fork locations are approved.

» Unit must be lifted by the four lifting holes located at the base frame corners.

» Lifting cables should be attached to the unit with shackles.

» The distance between the crane hook and the top of the unit must not be less than 60".

» Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base

Installation

frame before setting unit on roof curb. These struts are intended to protect unit base frame from forklift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit.

Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct.

Roof Curb InstallationThe roof curb is field-assembled and must be installed level (within 1/16" per foot side to side). A sub-base must be constructed by the contractor in applications involving pitched roofs. Gaskets are furnished and must be installed between the unit and curb. For proper installation, follow NRCA guidelines. In applications requiring post and rail installation, an I-beam securely mounted on multiple posts should support the unit on each side. In addition, the insulation on the underside of the unit should be protected from the elements. Applications in geographic areas subjected to seismic or hurricane conditions must meet code requirements for fastening the unit to the curb and the curb to the building structure. For further and more detailed information please refer to our Daikin Light Commercial Packaged unit IOD.

Corner & Center-of-Gravity Locations

Weights

A

ModelShipping

Weight (lbs)Operating

Weight (lbs)Corner Weights (lbs) Length Width

A B C D X (in) Y (in)

DBC0723* 724 678 141 219 72 246 34⅗ 207/10

Page 22: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

22 www.daikinac.com SS-DBC6

Field Accessory part number

DescriptionFits Model

SizesField-

InstalledFactory-Installed

Operating Weight (lbs)

Electric Heat Kits

EHXB-3S05 Electric Heater, Belt-Drive, 208-230V, 3PH, 5kW 3-6 ton √ √

EHXB-3S10 Electric Heater, Belt-Drive, 208-230V, 3PH, 10kW 3-6 ton √ √

EHXB-3S15 Electric Heater, Belt-Drive, 208-230V, 3PH, 15kW 3-6 ton √ √

EHXB-3S18 Electric Heater, Belt-Drive, 208-230V, 3PH, 18kW 4-6 ton √ √

EHXB-3S20 Electric Heater, Belt-Drive, 208-230V, 3PH, 20kW 4-6 ton √ √

EHXB-3S30 Electric Heater, Belt-Drive, 208-230V, 3PH, 30kW 6 ton √ √

EHXB-4S05 Electric Heater, Belt-Drive, 460V, 3PH, 5kW 3-6 ton √ √

EHXB-4S10 Electric Heater, Belt-Drive, 460V, 3PH, 10kW 3-6 ton √ √

EHXB-4S15 Electric Heater, Belt-Drive, 460V, 3PH, 15kW 3-6 ton √ √

EHXB-4S18 Electric Heater, Belt-Drive, 460V, 3PH, 18kW 4-6 ton √ √

EHXB-4S20 Electric Heater, Belt-Drive, 460V, 3PH, 20kW 4-6 ton √ √

EHXB-4S30 Electric Heater, Belt-Drive, 460V, 3PH, 30kW 6 ton √ √

EHXB-7S05 Electric Heater, Belt-Drive, 575V, 3PH, 5kW 3-6 ton √ √

EHXB-7S10 Electric Heater, Belt-Drive, 575V, 3PH, 10kW 3-6 ton √ √

EHXB-7S15 Electric Heater, Belt-Drive, 575V, 3PH, 15kW 3-6 ton √ √

EHXB-7S18 Electric Heater, Belt-Drive, 575V, 3PH, 18kW 4-6 ton √ √

EHXB-7S20 Electric Heater, Belt-Drive, 575V, 3PH, 20kW 4-6 ton √ √

EHXB-7S30 Electric Heater, Belt-Drive, 575V, 3PH, 30kW 6 ton √ √

Duct Smoke Detectors

Duct Smoke Detectors - Return 3-6 ton √ 11

Duct Smoke Detectors - Supply 3-6 ton √ 11

Duct Smoke Detectors - Supply and Return 3-6 ton √ 11

Non-Fused Disconnect Switch

60 Amp Disconnect 3-6 ton √ 5

100 Amp Disconnect 3-6 ton √ 5

150 Amp Disconnect 3-6 ton √ 5

Convenience Outlets

Convenience Outlets - Powered, 208/230 V 3-6 ton √ 42

Convenience Outlets - Powered, 460 V 3-6 ton √ 42

Convenience Outlets - Powered, 575 V 3-6 ton √ 42

Convenience Outlets - Non-Powered 3-6 ton √ 2

Hinged Access Panels

Hinged Access Panels, 43" cabinet 6 ton √

Economizer

0270L01598 Horizontal Economizer Ultra Low-Leak (Title 24) JADE® Dry-Bulb, 43" cabinet 6 ton √ 88

0270L01757 Horizontal Economizer Ultra Low-Leak (Title 24) JADE Enthalpy Sensor, 43" cabinet 6 ton √ 88

0270L01753 Vertical Economizer Standard Low-Leak JADE Ethalpy Sensor 3-6 ton √ √ 65

0270L01755 Vertical Economizer Ultra Low-Leak (Title 24) JADE Ethalpy Sensor 3-6 ton √ √ 65

0270L01156 Vertical Economizer Standard Low-Leak JADE Dry-Bulb 3-6 ton √ √ 65

0270L01158 Vertical Economizer Ultra Low-Leak (Title 24) JADE Dry-Bulb 3-6 ton √ √ 65

Curbs and Restraint Clips

0221L00014 Roof Curb 14" Tall, Knocked Down 3-6 ton √ 80

0221L00015 Roof Curb 24" Tall, Knocked Down 3-6 ton √ 109

0270L01261 Hold Down Bracket Kit 3-6 ton √ 8

0270L01250 Hold Down Bracket Kit for Daikin Roof curb 3-6 ton √ 8

0221L00019 Roof Curb 14" Tall Seismic with Hold Down Brackets, Knocked Down 3-6 ton √ 102

0221L00020Roof Curb 14" Tall Wind-Rated Hurricane with Hold Down Brackets, Welded

3-6 ton √ 140

Accessories

Accessories availability may vary.

Page 23: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Accessories

SS-DBC6 www.daikinac.com 23

Field Accessory part number

DescriptionFits Model

SizesField-

InstalledFactory-Installed

Operating Weight (lbs)

Concentrics

0270L01602 Concentric Diffuser 24 x 48 with 16" Dia. collars 3-6 ton √ 32

0270L01603 Concentric Diffuser 24 x 48 with 18" Dia. collars 3-6 ton √ 35

0270L01335 Concentric Duct Adaptor Kit for 16" Dia. Duct 3-6 ton √ 28

0270L01338 Concentric Duct Adaptor Kit for 18" Dia. Duct 3-6 ton √ 28

Damper

0270L01165 2 Position Motorized Damper 3-6 ton √ 40

0270L01166 Manual Outdoor Air Damper 3-6 ton √ 24

Hail Guard Kits

HAILGD048060HE Condenser Coil Hail Guards, 43" cabinet 6 ton √ √

Crankcase Heater Kits

HECH4860230 Crankcase heater Kit 208/230 V 4-6 ton √ 1

HECH4860460 Crankcase heater Kit 460 V 4-6 ton √ 1

HECH4860575 Crankcase heater Kit 575 V 4-6 ton √ 1

High-Efficiency Filters

0160L00268 High-Efficiency MERV 8 Air Filter Kit - 14x20x2 (qty 2) 6 ton √ 4

0160L00270 High-Efficiency MERV 8 Air Filter Kit - 20x20x2 (qty 2) 6 ton √ 4

0160L00204 High-Efficiency MERV 13 Air Filter Kit - 14x20x2 (qty 2) 6 ton √ 4

0160L00201 High-Efficiency MERV 13 Air Filter Kit - 20x20x2 (qty 2) 6 ton √ 4

Misc Accessories

TTBCKHE01 Through the Base Gas/Electrical 3-6 ton √ √ 1

3PMKP1 Phase Monitor Kit 3-6 ton √ √ 2

0270L01232 Burglar bars Inserts 3-6 ton √ 18

Power Exhaust

0270L01167 Power Exhaust Prop Downflow Economizer, 230 V 3-6 ton √ 57

0270L01170 Power Exhaust Prop Horizontal Economizer, 230 V 3-6 ton √ 47

0270L01171 Power Exhaust Prop Horizontal Economizer, 460 V 3-6 ton √ 57

0270L01168 Power Exhaust Prop Downflow Economizer, 460 V 3-6 ton √ 47

Controls, Thermostats and Sensors

DT4272C Comm Touch Digital Stat w/ Wi-Fi 4h/2c 3-6 ton √ 1

DT4273C Comm Touch Digital Stat w/ Wi-Fi & Humidity Control 4h/2cc 3-6 ton √ 1

TSTATGAC-WS Remote indoor sensor 3-6 ton √ 1

250803400 AppStat™ RTU 2H/2C Econ 3-6 ton √ 1

250803600 AppStat™ RTU 3H/2C Econ (HP only) 3-6 ton √ 1

D4271C 4h/2c Commercial 7 day Programmable Wi-Fi Capable thermostat 3-6 ton √ 1

D4272C4h/2c Commercial 7 day Programmable Wi-Fi Capable Hum/dehum thermostat

3-6 ton √ 1

C7232B1022 CO2 Sensor (Duct Mtd) 3-6 ton √ 1

D2270C Mini Wi-Fi Thermostat 3-6 ton √ 1

Note: Where multiple variations are available, the heaviest combination is listed. Accessories availability may vary.

Page 24: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Factory and Field Installed Options

24 www.daikinac.com SS-DBC3-B

DBC6

Factory Installed Options » Non-Powered Convenience Outlet: A 120V, 15A, GFCI outlet

can be installed in the unit making it easier for technicians to service other units once an electrician runs power to the outlet. Outlet shall be factory-installed and internally mounted with easily accessible 120-v female receptacle. Transformer not included for this option. Outlet shall include a field-installed “While-in-Use” cover.

» High-Static Kit: Allows for operation in higher static applications.

» Powered Convenience Outlet: A 120V, 15A, GFCI outlet can be powered with a step-transformer built into the unit. For use when the unit is not running. When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.5A for 208/230V units; increase by 3.75A for 460V units; and by 3A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. Outlet shall be powered from main line power to the rooftop unit. Outlet shall include a field-installed “While-in-Use” cover.

» Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors can be installed in the unit. To safely identify the presence of smoke inside the air conditioning system and shutdown the blower to prevent the smoke to disperse into different zones.

» Disconnect Switch (non-fused): A disconnect switch can be installed in the unit with factory wiring complete from the switch to the unit. Please note that for air conditioner and heat pump units, the appropriate electric heat kit must be ordered along with the disconnect switch (non-fused) to be factory-installed. For models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. National Electric Code (NEC) and UL approved non-fused switch shall provide unit power shutoff. The switch shall be accessible from outside of the unit and provide local shutdown and lockout capability.

» Hinged Access Panels: Allows access to unit’s major components. Combined with latches for easy access to control box, compressor, filters and blower motor.

» Through-the-base electrical connection: Allows an easy and fast field installation through the unit base pan.

» Electromechanical Controls: Basic controls that include terminal block for unit connectivity to T-Stat.

Field Installed Options » Manual Fresh Air Damper: Manual damper package shall

consist of damper, air inlet screen, and rain hood which can be preset to admit up to 25% outdoor air for year round ventilation.

» Motorized Fresh Air Damper: A two-position damper with rain hood and screen provides up to 50% outside air when the indoor fan starts and closes when the indoor fan shuts down. Consist of actuator, damper, air inlet screen, and rain hood. Damper shall close upon indoor (evaporator) fan shutoff and/or loss of power. The damper actuator shall plug into the rooftop unit’s wiring harness plug. No hard wiring shall be required.

» Power Exhaust: Power exhaust shall be used in conjunction with an integrated economizer. This accessory exhausts return air and may be used in either downflow or horizontal (duct-mounted) applications. Horizontal power exhaust shall be mounted in return ductwork. Power exhaust shall be controlled by economizer controller operation. Exhaust fans shall be energized when dampers open past the 0-100% adjustable setpoint on the economizer control.

» Horizontal Economizer: Fully modulating between 0 and 100%, contain seals that meet ASHRAE 90.1 requirements. Includes motor and dampers, minimum position settings, preset linkage, wiring harness with plug, mixed air temperature sensor, and enthalpy control. An optional duct-mounted barometric relief damper is available. An optional return enthalpy sensor is available to provide comparative or differential enthalpy control. Damper blades shall be galvanized steel with composite gears. Plastic or composite blades on intake or return shall not be acceptable. Standard leak rate shall be equipped with dampers not to exceed 2% leakage at 1 in. wg pressure differential. Ultra Low Leak design meets California Title 24 section 140.4 and ASHRAE 90.1 requirements for 4 cfm per sq.ft. on the outside air dampers and 10 cfm per sq. ft. on the return dampers. Shall be designed to close damper(s) during loss-of-power situations with spring return built into motor. Economizer controller shall accept a 2-10 Vdc CO2 sensor input for IAQ/DCV control. In this mode, dampers shall modulate the outdoor air damper to provide ventilation based on the sensor input.

» Economizer controller shall be Honeywell® JADE® W7220 that provides:

- 2-line LCD interface screen for setup, configuration and troubleshooting.

- On-board Fault Detection and Diagnostics (FDD) that senses and alerts when the economizer is not operating properly, per California Title 24.

- Sensor failure loss of communication identification

- Automatic sensor detection

- Capabilities for use with multiple-speed indoor fan systems

- Utilize digital sensors: Dry bulb and Enthalpy

- Economizer controller shall provide indications when in free cooling mode, in the DCV mode, or the exhaust fan contact is closed.

Page 25: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Factory and Field Installed Options

SS-DBC6 www.daikinac.com 25

» Roof curbs: Full perimeter roof curb with exhaust capability providing separate air streams for energy recovery from the exhaust air without supply air contamination. Two different heights 14" and 24", allows proper installation and structure stability. Formed galvanized steel with wood nailer strip and shall be capable of supporting entire unit weight.

» Concentric duct kits: Designed to provide a single-point air distribution system with the added benefit of having directional air control.

» Restraint mounting clips: Allows for installation reinforcement for Hurricane and/or seismic events.

» CO2 sensor: Sensor designed to alarm the system when the CO2 levels are outside safe parameters.

» Burglar Bar Sleeves: Designed to prevent the access thru the return or supply ducting inside the unit.

» Downflow square to round adapter 18": Installed into a recessed portion of the roof curb, the concentric duct adaptor changes the orientation of the ductwork from square to round for applications utilizing that type of ducting system.

» Side discharge concentric diffuser system: The Concentric diffuser system is an all in one supply and return duct free arrangement for RTU systems. This system comes with two separate duct connections, one for a supply and another for a return.

» Remote indoor sensor: Remote sensor to monitor the temperature on zones away from the main thermostat.

» Drain pan overflow switch: Allows the controls to detect and send an alarm when there is an overflow on the drain pan.

» Freeze stat: Temperature sensing device that monitors the heat exchange to prevent the coil from freezing.

Factory and Field Installed Options » Downflow Economizer: Fully modulating between 0 and

100%, contain seals that meet ASHRAE 90.1 requirements. Includes motor and dampers, minimum position settings, a preset linkage, a wiring harness with plug, a mixed air temperature sensor, enthalpy control, and a barometric relief damper. An optional return enthalpy sensor is available to provide comparative or differential enthalpy control. Damper blades shall be galvanized steel with composite gears. Plastic or composite blades on intake or return shall not be acceptable. Standard leak rate shall be equipped with dampers not to exceed 2% leakage at 1 in. wg pressure differential. Ultra Low Leak design meets California Title 24 section 140.4 and ASHRAE 90.1 requirements for 4 cfm per sq.ft. on the outside air dampers and 10 cfm per sq. ft. on the return dampers. Shall be designed to close damper(s) during loss-of-power situations with spring return built into motor. Economizer controller shall accept a 2-10 Vdc CO2 sensor input for IAQ/DCV control. In this mode, dampers shall modulate the outdoor air damper to provide ventilation based on the sensor input. Economizer controller shall be Honeywell® W7220 that provides:

» Economizer controller shall be Honeywell W7220 that provides:

- 2-line LCD interface screen for setup, configuration and troubleshooting.

- On-board Fault Detection and Diagnostics (FDD) that senses and alerts when the economizer is not operating properly, per California Title 24.

- Sensor failure loss of communication identification

- Automatic sensor detection

- Capabilities for use with multiple-speed indoor fan systems

- Utilize digital sensors: Dry bulb and Enthalpy

- Economizer controller shall provide indications when in free cooling mode, in the DCV mode, or the exhaust fan contact is closed.

» Low Ambient Control: Allows cooling operation down to 35°F outdoor ambient temperature for 3 - 6 ton units.

» Phase Monitor: Phase monitor (3-Phase only) shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator.

» Condenser Hail Guards: Louvered metal guards help protect the condenser coil from hail and debris; available as a field-installed options on 3 – 12½ ton units.

Page 26: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Notes

26 www.daikinac.com SS-DBC6

Page 27: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

Notes

SS-DBC6 www.daikinac.com 27

Page 28: DBC Commercial - Daikin · DBC Commercial 6 Nominal Tons 15 IEER / 11.2 EER *te warranty details available from your local distributor or manufacturer’s representative Comple or

28 www.daikinac.com SS-DBC6

Our continuing commitment to quality products may mean a change in specifications without notice. © 2021 • Houston, Texas • Printed in the USA.

Notes