Upload
others
View
5
Download
1
Embed Size (px)
Citation preview
DSCM
Deployment and Configuration Guide
Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays
Abstract This document provides guidance on host and switching devices that are
validated for use with Dell EMC™ SC Series, Dell™ PS Series, and Dell FS
Series (FluidFS) storage solutions.
December 2019
Table of contents
2 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Table of contents 1 Overview ....................................................................................................................................................................... 5
1.1 Definitions ........................................................................................................................................................... 5
1.2 Abbreviations and Terminology .......................................................................................................................... 5
1.3 Conventions used in this document ................................................................................................................... 7
2 Dell Storage support policy statement ......................................................................................................................... 8
2.1 Level 1: Full contractual support ......................................................................................................................... 8
2.2 Level 2: Conditional support ............................................................................................................................... 8
2.3 Level 3: Commercially reasonable effort ............................................................................................................ 9
2.4 Level 4: No support ............................................................................................................................................ 9
2.5 Support for cross-platform coexisting solutions .................................................................................................. 9
2.6 FS Series additional support statement ........................................................................................................... 10
2.6.1 Switch support policy ........................................................................................................................................ 10
2.6.2 Client OS environment support policy .............................................................................................................. 11
2.6.3 MD Series support policy statement ................................................................................................................. 11
2.7 Other statements .............................................................................................................................................. 11
2.7.1 Operating system, switch, and server adapter settings.................................................................................... 11
2.7.2 Server interoperability ....................................................................................................................................... 11
2.7.3 Host connectivity adapters and server vendor support .................................................................................... 12
2.7.4 Persistent FCIDs............................................................................................................................................... 12
2.7.5 Limits of supportability ...................................................................................................................................... 12
3 Switches ..................................................................................................................................................................... 13
3.1 Fibre Channel Switches (SC, SCv, and FS Series) ......................................................................................... 13
3.2 Fibre channel over Ethernet Switches (SC Series) .......................................................................................... 14
3.3 iSCSI Switches ................................................................................................................................................. 15
3.3.1 1/10 iSCSI Switches (SC, SCv, and FS Series) ............................................................................................... 15
3.3.2 25/100Gb iSCSI Switches (SC, SCv Series) .................................................................................................... 16
3.3.3 1/10Gb Switches (PS Series) ........................................................................................................................... 17
3.4 iSCSI over DCB support (SC, SCv and PS Series) ......................................................................................... 24
4 Host connectivity ........................................................................................................................................................ 29
4.1 Required Adapter and Server OS Settings ...................................................................................................... 29
4.2 Fibre Channel Adapters (SC and SCv Series) ................................................................................................. 30
4.3 iSCSI Adapters ................................................................................................................................................. 63
4.3.1 iSCSI converged network and host bus adapters (SC and SCv Series).......................................................... 63
4.3.2 Software iSCSI initiators (SC and SCv Series) ................................................................................................ 70
4.3.3 iSCSI converged network and host bus adapters (PS Series) ......................................................................... 75
Table of contents
3 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4.3.4 Network interface cards for boot from SAN and DCB support for iSCSI (PS Series) ...................................... 82
4.3.5 Software iSCSI initiators (PS Series) ............................................................................................................... 85
4.4 SAS Adapters (SC and SCv Series)................................................................................................................. 87
4.5 Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series) .................................................................... 94
4.5.1 FCoE converged network and host bus adapters (SC, SCv Series) ................................................................ 94
4.5.2 Software FCoE initiators (SC and SCv Series) ................................................................................................ 98
5 Other support matrices ............................................................................................................................................... 99
5.1 Cisco UCS support ........................................................................................................................................... 99
5.2 Storage virtualization appliances ...................................................................................................................... 99
5.3 KMS solutions ................................................................................................................................................... 99
5.4 Data Protection ................................................................................................................................................. 99
A Required Adapter and Server OS Settings .............................................................................................................. 100
A.1 Adapter Settings ............................................................................................................................................. 100
A.1.1 Cisco Fibre Channel Adapters ........................................................................................................................ 100
A.1.2 Emulex Fibre Channel Adapters ..................................................................................................................... 100
A.1.3 QLogic Fibre Channel Adapters (and re-branded adapters based on QLogic) ............................................. 100
A.2 Server OS Settings ......................................................................................................................................... 102
A.2.1 Windows Server 2008r2 ................................................................................................................................. 102
A.2.2 Windows Server 2012 and Later .................................................................................................................... 107
A.2.3 Linux (Red Hat, SuSE, Oracle, Ubuntu) ......................................................................................................... 113
A.2.4 VMware ........................................................................................................................................................... 116
A.2.5 Oracle Solaris ................................................................................................................................................. 117
A.2.6 IBM AIX ........................................................................................................................................................... 118
A.2.7 Citrix Hypervisor (XenServer) ......................................................................................................................... 119
A.2.8 HP-UX 11i ....................................................................................................................................................... 120
B SC and SCv Fibre Channel Zoning .......................................................................................................................... 121
C Deprecated devices .................................................................................................................................................. 122
C.1 Host configurations ......................................................................................................................................... 122
C.1.1 SC Series ........................................................................................................................................................ 122
C.1.2 PS Series ........................................................................................................................................................ 131
C.2 Deprecated switches ...................................................................................................................................... 135
C.2.1 SC Series and PS Series ............................................................................................................................... 135
C.2.2 FS Series ........................................................................................................................................................ 137
D Technical support and additional resources ............................................................................................................. 138
D.1 Related documentation ................................................................................................................................... 138
D.2 RPQ process .................................................................................................................................................. 138
Table of contents
4 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this
publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose.
Use, copying, and distribution of any software described in this publication requires an applicable software license.
Copyright © 2015–2019 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc. or its
subsidiaries. Other trademarks may be trademarks of their respective owners. [12/18/2019] [Deployment and Configuration Guide] [DSCM]
Overview
5 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
1 Overview This compatibility matrix describes SAN components (such as switches, host bus Adapters, and operating
systems) that have been tested in Dell storage labs. The testing results demonstrate that Dell SC Series, PS
Series, and FS Series products, as tested and under normal operating conditions, will operate as expected
and as described in Dell Storage product documentation.
The first portion of this document describes the Dell commitment to supporting the various products that have
been tested and those products or components that have not been tested. This section describes a multi-
tiered support policy that describes any limitations to a customer’s supportability for Dell and non- Dell
components when those components or their constituent software (such as drivers and firmware) are not
listed in this matrix.
The second part of this document lists switches that have been tested and confirmed to be interoperable with
Dell SC Series, PS Series, and FS Series products. The resulting configurations are separated by networking
technology (Fibre Channel or Ethernet) and product vendor/model.
The final section of this document details the hardware and software used when testing different host network
connectivity devices (network interface controllers, converged network Adapters, and host bus Adapters) and
storage initiators in a variety of operating-system environments. The results are separated by protocol and
then grouped by operating system.
1.1 Definitions For the purposes of this document, the following definitions apply:
Storage solution: The end-to-end set of components, such as the operating system, network controller,
switch, and switch firmware, and array firmware that permits a host to target communication.
Component: The individual parts of a storage solution in the form of host network interface Adapters, iSCSI
initiators, iSCSI host bus Adapters, switches, and arrays.
Comparable models: These can include similar devices based on the same architecture and from the same
vendor, or newer firmware versions.
1.2 Abbreviations and Terminology Abbreviations and terminonolgy used in this document are defined below.
Abbreviation Term Descriptions
L1, L2, L3 Level 1, Level 2, Level 3
The support level provided for a particular feature (see the section, Dell Storage support policy statement for details)
BfS Boot from SAN A general term referring to functionality on a CNA/HBA/NIC to allow bare-metal OS boot from a remote, SAN-based target/LUN/volume
CNA Converged network Adapter
A networking device that supports DCB and can manage more than one class of network traffic, typically consisting of storage and non- storage traffic types
Overview
6 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Abbreviation Term Descriptions
Conv Converged Ethernet (DCB) capable switch
Includes functionality to support FC native and Ethernet native ports in the same switch to facilitate support for FC/FCoE/TCP functionality
DCB Data Center Bridging
Used to support converged networking solutions that host FCoE or iSCSI traffic and TCP/IP traffic simultaneously
Eth Ethernet The most common type of general purpose networking defined by a group of standards maintained by the Institute of Electrical and Electronics Engineers (IEEE)
FC Fibre Channel A networking technology used in storage networks
FCoE Fibre Channel over Ethernet
A storage protocol that enables Fibre Channel communication over Ethernet networks
FW Firmware Typically, the main operating system for an appliance-type device or component such as a NIC, switch, or other device; typically, not user- interactive, though it may contain subsystems that provide user interaction such as a command line interface
HBA Host bus Adapter Indicates a device that provides hardware-based FC/FCoE/iSCSI storage functionality
iBFT iSCSI Boot Firmware Table
A specific, standards-based BfS technology that supports booting from iSCSI-protocol-based targets; part of the ACPI 3.0 standard
MLAG Multi-chassis link aggregation
General term or specific feature offering by some switch vendors for switch-to-switch multipath interconnection
NA Not applicable This feature or function is not applicable
NIC Network interface controller
A networking device that provides Ethernet and optional TCP/IP functionality and may or may not provide SAN/network boot functionality; for SAN solutions, this requires a software-based protocol initiator (FCoE/iSCSI) to access SAN remote targets
OS Operating system The core software of a system
RTM Release to manufacturing
Initial-release version of an operating system from the vendor
SC/SCOS Storage Center Operating System
The core software of the SC Series products that provides all storage and management functionality
VLT Virtual Link Trunking
Proprietary switch-to-switch multipathing solution provided by certain Dell Networking switch products
vPC Virtual Port Channel
Proprietary switch-to-switch multipathing solution provided by certain Cisco® network products, specifically Cisco Nexus® products
In-box The version included with each release of a given operating system by the vendor
OS Operating system The core software of a system
Overview
7 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
1.3 Conventions used in this document Blue Text is used for all section titles. When visible in body text or tables, blue text indicates a change or
addition from the previous version of the Dell Storage Compatibility Matrix (DSCM).
The remainder of the DSCM is organized by storage network component family starting with section 3. The
following hierarchy is used:
• Component class (switch, host connectivity adapters, other components)
• Array family (SC, SCv, PS, FS)
• Component tables by storage protocol (FC, FCoE, iSCSI, etc.)
Dell Storage support policy statement
8 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
2 Dell Storage support policy statement This compatibility matrix details devices that have been tested by Dell storage test labs. While Dell tests on a
wide variety of devices, it is impossible to test every device or version for all vendors with which Dell Storage
products can interoperate. Therefore, the information presented in this document does not constitute a
complete list of what is supportable, but simply a list of what has been specifically tested.
Regardless of the support level (described in the following sections), Dell Storage customers will
always be provided full contractual support of their storage solution.
Each row in a table defines a SAN component and the software or firmware that was tested with that
component. Each of these entries constitutes a supportable configuration.
Based on this matrix, a customer configuration will be classified into one of three levels of supportability
described below. Each level of supportability also references the requirement for designing the SAN
subsystem using recommended practices suitable for the each Dell Storage product family. These
recommended practices are documented in a variety of technical white papers as well as consolidated in the
Dell EqualLogic Configuration Guide and the Dell SC Series knowledge center.
Contact your Dell sales representative with questions about how to classify your proposed configuration.
2.1 Level 1: Full contractual support For tested components listed in this compatibility matrix, (and for the specific firmware or software version
listed), Dell will provide solution support under an active Dell ProSupport™ or Copilot support contract,
assuming that all other components in the storage solution are also under contracted support with their
respective manufacturers and that documented, recommended design best practices are followed.
Note: The exception is that iSCSI switches are not specifically listed in the support matrix. They are however
supported if they meet the criteria specified in section 3.3.1.
2.2 Level 2: Conditional support In addition to the component versions tested by Dell and listed in this compatibility matrix, the compatibility of
comparable hardware models can be projected based upon the results for the systems actually tested and will
be designated as conditionally supported.
Dell will provide full contractual support for the storage solution under an active ProSupport or Copilot support
contract, assuming that all components in the storage solution are also under contracted support with their
respective manufacturers and that documented, recommended design best practices are followed.
Resolution of functional and/or performance issues may be out of Dell control. In such cases, these issues will
need to be addressed by the applicable component or software/firmware vendor. If these issue(s) cannot be
resolved in a timely manner by Dell or the component vendor, Dell may require, in its sole discretion and as a
condition of continuing support, that the customer replace the component in question with one that was tested
and/or will upgrade or downgrade to a supported software version.
Examples of conditional support situations include, but are not limited to:
• If a switch or server Adapter shares the same underlying ASIC or chipset and is from the same
vendor as a tested configuration, then it may produce similar results.
Dell Storage support policy statement
9 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
• If a component is an identical model of a component listed, but differs in firmware or driver version, it
may produce similar results for any firmware and/or drivers that are newer than those listed. For
example, if version X of software/firmware has been tested and is listed as Level 1, then
software/firmware versions newer than version X are expected to work.
Failure of a conditionally supported component to provide the same service level as the similar device listed
(unless Dell has communicated end of support or a specific incompatibility for a particular product, firmware,
or software version) would be treated as a bug that needs to be fixed by the device or software/firmware
vendor.
2.3 Level 3: Commercially reasonable effort Level 3 support applies to components not listed within this compatibility matrix, or instances in which a
customer has not or is not willing to apply accepted Dell recommended practices for the specific storage
family’s SAN design and implementation. If the customer has an active support contract with the
appropriate vendor(s), and an active ProSupport or Copilot support contract, Dell will provide storage
solution full contractual support for all Dell branded components and provide commercially
reasonable effort (CRE) support for any untested component of the configuration. This support level
lasts until such time as it is determined, in Dell’s sole discretion that a problem lies within the
untested component or results from the way they interoperate with Dell components.
Dell does not guarantee that issues undertaken on a CRE basis will be resolved in a timely fashion, or at all.
There is a possibility that the customer would need to replace an untested component or take the affected
system out of production to resolve the issues.
2.4 Level 4: No support Level 4 indicates that the device is not supported in any way for use with the specified array family as listed.
While this is not a common occurrence, there are situations where specific features or functions required to
support the array are not available in the device listed.
2.5 Support for cross-platform coexisting solutions Cross-platform coexisting solutions are defined as SAN environments that host more than one storage
platform technology. In general, this could be two or more array technology solutions from the same vendor or
different vendors. Examples include:
• A SAN solution that is hosting a Dell SC Series array as well as an EMC array solution, while sharing
the same network resources
• A SAN solution that is hosting a Dell SC Series array as well as a Dell PS Series array solution, while
sharing the same network resources
Dell supports the following scenarios involving two or more array solutions sharing a common network
infrastructure:
• A Dell PS Series SAN infrastructure introducing or adding a Dell SC Series array solution to the
existing PS Series SAN
Note: Any other array coexistence solution is not supported at the time of the publish date of this document.
Dell Storage support policy statement
10 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
This scenario implies that certain criteria will be assumed and only these configurations will receive Level 1
support:
• iSCSI only
• A single IP subnet
• PS Series Host Integration Tools may (or may not) be installed on individual hosts where supported
To determine the support level of the coexistence solution, the following rules apply:
• Level 1 support is provided, assuming that for each array solution (PS Series and SC Series), all of
the components used (operating systems, Adapters, and switches) are listed in the matrices included
in this document, and that the support policy statement described earlier in this document is applied
to each solution
• Level 2 support is provided if any included component qualifies for Level 2 support for either of the
array solutions
• Level 3 support is provided for any other solutions
2.6 FS Series additional support statement The FS Series of products are NAS appliances that work with the various Dell Storage PS Series and SC
Series products. All FS Series products are tested for interoperability with their respective back-end storage
array products, and Dell will support any and all issues arising in or between these products while the
products are under warranty and/or under an active ProSupport or Copilot support contract for both products.
The following sections describe general support policies for the FS Series, particularly as they relate to the
results published in this document. There are additional environmental and cabling considerations that should
be taken into account when building a storage solution that includes FS Series NAS appliances.
Please consult other FS Series documentation or contact your Dell account representative to ensure that all
the relevant factors have been taken into consideration.
2.6.1 Switch support policy Dell tests switches for two of the three networks associated with an FS Series NAS cluster, namely the back-
end iSCSI or Fibre Channel (FC) network situated between the NAS controllers and the PS Series or SC
Series storage arrays. The FS76x0 Series NAS appliances connect to the PS Series SAN arrays using the
industry-standard iSCSI protocol, while the FS8000 Series NAS appliances connect to the SC Series SAN
arrays using either iSCSI or Fibre Channel. For proper configuration, at least one switch is required (a
minimum of two switches is recommended) to interconnect these products. Direct connection of any FS
Series NAS appliances and the respective arrays is not supported.
The three levels of support described previously are applicable to the FS Series switches listed in this matrix
for back-end network configuration.
There are two other networks associated with an FS76x0 Series cluster, namely the front-end connection to
the customer’s existing client network, and the cluster or private interconnect network for communication
between FS76x0 Series controllers. Both of these networks are Ethernet based.
Any Ethernet switch listed for use as a back-end switch is also valid for use as a private interconnect network
switch and can be used for both back-end and private simultaneously.
Dell Storage support policy statement
11 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
2.6.2 Client OS environment support policy Although Dell tests the FS Series NAS solution in a variety of client operating system environments, this
document does not provide resulting compatibility data. The statements made with respect to compatibility for
the FS Series in this document are not to be construed as a guarantee of interoperability or supportability of
client operating systems.
2.6.3 MD Series support policy statement The following MD Series array products have separate set of support documentation currently available on
the website:
• MD34xx/38xx : http://dell.to/1Ov6cYQ
• MD32xx/36xx : http://dell.to/1HOZiZP
General support is provided as follows:
• Level 1 support for iSCSI and FC for all industry-standards-based switches
• Level 1 support for iSCSI software-based initiators for the supported shipping versions of the
following operating systems:
• Microsoft® Windows®
• Red Hat® Enterprise Linux®
• SUSE® Linux Enterprise Server
• VMware® ESX®/ESXi™
• Level 1 support for all standards-based Ethernet NICs for use with the above iSCSI software-based
initiators, including those that support TCP-offload functionality
• Level 1 support for all RFC 3720 compliant iSCSI hardware-based initiators/HBAs
• Level 1 support for Brocade®, QLogic®, and Emulex® Fibre Channel HBAs as listed in section 18 of
the support matrix documents listed previously in this section.
All other devices and software not currently listed previously or in the linked support matrix documents would
be supported on a Level 3 (commercially reasonable effort) basis.
2.7 Other statements
2.7.1 Operating system, switch, and server adapter settings Although this document does not cover recommended practices, optimized SAN or NAS solutions consisting
of supported hardware and software (as defined in this document) are based on recommended practices
documented in Dell white papers. These documents are downloadable from Dell Support and are frequently
updated with recommended practices and recommended settings for various operating systems, switches,
and server adapters.
2.7.2 Server interoperability This compatibility matrix details interoperability from the storage array to various server hosts through a
switched network and one or more network Adapters or host bus Adapters (HBAs). Testing of, and support
for, a specific server platform (such as Dell PowerEdge™ servers) was not performed as part of this program
and customers should visit the server vendor’s website to determine which operating systems and Adapters
are supported by the server vendor.
Dell Storage support policy statement
12 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
2.7.3 Host connectivity adapters and server vendor support This matrix lists many host network Adapters and HBAs that have been tested for use within the indicated
Dell Storage array family SAN environment. It is not implied that all of these Adapters and their
driver/firmware stacks are supported by any or all server vendors. The reader must ensure that the host
network Adapter and its associated drivers are included on the vendor's hardware compatibility list. This
recommendation also applies to Dell PowerEdge server products. Inclusion in this document's adapter
compatibility tables should not be interpreted as that adapter and driver/firmware combination as being
supported by any vendor’s for use with their server products.
2.7.4 Persistent FCIDs With HP-UX 11i v1 and v2, it is recommended to operate Storage Center in Legacy port mode in concurrence
with the use of Persistent FCID (Cisco) or Persistent PID (Brocade FOS v6.0.4 or newer & 8GB only)
switches (switch-wide or per VSAN accordingly to vendor specifications).
With HP-UX 11i v3 (Agile Addressing/Naming), the Storage Center can be operated in either Legacy or
Virtual port modes. The use of Persistent FCID or Persistent PID is not required for use with HP-UX 11i v3.
Additional information regarding switch level port persistency can be obtained from published Copilot Services
Technical Alerts (CSTAs) located on Knowledge Center at the Dell SC Customer Portal.
The Dell Storage Software Suite for AIX v2.2.0.x introduces new features, enhancements and remove the
need of certain legacy requirements. These new features and enhancements are as noted below. This will be
the only package made available by Dell to customers requesting this driver package and will replace the
existing PCM v1.2.0.1 (and v1.0.0.5) currently in use.
• Supports AIX v6.1 thru v7.1
• Supports use of Storage Center in Virtual port mode
• Negates the need of use of Persistent FCID/PID-enabled switches
• Enhanced hdisk lscfg details
• Allows AIX OS to survive Storage Center controller failover events of up to 60 seconds
2.7.5 Limits of supportability If any recommendations made by Dell to resolve customer issues — whether they are functional or
performance related — are not followed, Dell cannot guarantee that the issue can be resolved to the
satisfaction of the customer. The ability of Dell to provide customer support is dependent on the customer’s
willingness to implement solution recommendations from Dell.
Fibre Channel Switches (SC, SCv, and FS Series)
13 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
3 Switches
3.1 Fibre Channel Switches (SC, SCv, and FS Series) Fibre Channel switches listed in this section are supported at Level 1 (as described previously) for the listed
switch firmware versions. Switches listed in this table are supported with Storage Center OS (SCOS) and
FluidFS. Unless specifically stated in the notes column, SCOS 6.6 or later is required.
Switches listed below, with a “Switch Type” of “Converged” are also supported for use with FCoE servers as
listed in the Fibre Channel over Ethernet (FCoE) Adapter section.
Fibre Channel zoning requirements, as shown in Appendix B, Fibre Channel Zoning, must be observed in
order to maintain IO during Storage Center controller failovers and network/fabric path failovers.
OEM Switch Model Connectrix Switch Model
Switch Type Switch Firmware
Switch Notes
Brocade 300 DS-300B FC 7.3.x
Brocade 300 DS-300B FC 7.4.x
Brocade 6505, 6510, 6520
DS-6505B, DS-6510B, DS-6520B
FC 7.4.x
Brocade 6505, 6510, 6520
DS-6505B, DS-6510B, DS-6520B
FC 8.1.x SCOS 7.2.x or later
Brocade 6505, 6510, 6520
DS-6505B, DS-6510B, DS-6520B
FC 8.2.x SCOS 7.2.x or later
Brocade DCX-8510-4 ED-DCX8510-4B FC 7.3.x
Brocade DCX-8510-4 ED-DCX8510-4B FC 7.4.x
Brocade G610, G620, G630, X6
DS-6610B, DS-6620B, DS-6630B, ED-DCX6
FC 8.0.x SCOS 7.1.x or later
Brocade G610, G620, G630, X6
DS-6610B, DS-6620B, DS-6630B, ED-DCX6
FC 8.1.x SCOS 7.2.x or later
Brocade G610, G620, G630, X6
DS-6610B, DS-6620B, DS-6630B, ED-DCX6
FC 8.2.x SCOS 7.2.x or later
Cisco MDS 91xxS family MDS 91xxS family FC 8.2(x) SCOS 7.2.x or later
Cisco MDS 92xx family MDS 92xx family FC 6.2(x)
Cisco MDS family MDS 91xx family FC 6.2(x)
Cisco MDS family MDS 91xx family FC 8.2.x SCOS 7.2.x or later
Cisco Nexus 55xxUP family
- Converged 7.2(x) SCOS 6.7.x or later
Cisco Nexus 55xxUP family
- Converged 7.3(x)
Cisco UCS 6324 FI - Converged 3.0(x)
Cisco UCS 6324 FI - Converged 3.1(x)
Dell FN2210S - Converged 9.9(x)
Dell M6505 - FC 7.4.x
Dell M6505 - FC 8.1.x SCOS 7.2.x or later
Dell MX9116n - Converged 10.4(x) SCOS 7.2.x or later; 16Gb FC Direct Connect Only
Dell MXG610s - FC 8.1.0_lnx2 SCOS 7.3.x or later
Dell MXL Blade - Converged 9.8(x)
Dell MXL Blade - Converged 9.9(x)
Fibre channel over Ethernet Switches (SC Series)
14 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
3.2 Fibre channel over Ethernet Switches (SC Series) Fibre Channel over Ethernet (FCoE) switches listed in this section are supported at Level 1 (as described
previously) for the listed switch firmware versions. Switches listed in this table are supported with any
Storage Center OS (SCOS) 5.5.x or later.
Switches listed in the Fibre Channel Switches section, with a “Switch Type” of “Converged” are also
supported for use with FCoE servers as listed in the Fibre Channel over Ethernet (FCoE) Adapter section.
OEM Switch Model Switch Type Switch Firmware Switch Notes
Cisco Nexus 55xxUP family Converged 7.2(x) SCOS 6.7.x or later
Cisco Nexus 55xxUP family Converged 7.3(x)
Dell M8428-k Ethernet v6.4.x
Dell S4148U - Converged 10.4(x) SCOS 7.2.x or later
1/10 iSCSI Switches (SC, SCv, and FS Series)
15 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
3.3 iSCSI Switches
3.3.1 1/10 iSCSI Switches (SC, SCv, and FS Series) Dell supports the use of a 1/10Gb Ethernet switch for use within SC Series iSCSI SAN solutions which meets
a minimum set of criteria that Dell has determined are necessary to ensure the proper functionality of the SAN
solution.
Note: For FluidFS, the iSCSI SAN switch may also be used for Interconnect (in multi-appliance
configurations) and so Jumbo Frames should be supported independently of storage array.
Dell ProSupport service offerings will provide customers contractual support (Level 1 support) for iSCSI SAN
based connectivity in a dedicated SAN infrastructure using any Ethernet switch that provide the following
functionality and features:
• All switching components in the SAN must have active support contracts in place with device vendor
• Non-blocking backplane
• Link level flow control (IEEE 802.3x) on ingress/inbound switch ports (also known as “Rx Flow
Control” or “receive-side flow control” from the switch port’s point of view)
• Dynamic packet buffer management with a minimum of:
• 4MB of packet buffer for 1Gbps switches
• 9MB of packet buffer for 10Gbps switches
• Ability to configure ports to immediate forwarding state for edge ports (may be known as “portfast”
mode)
• Jumbo Frames (MTU 9000+ bytes) support if enabled on storage array
• Unicast storm control configuration
• VLAN and VLAN Tagging support
• Switch has a valid support contract in effect from the switch vendor at the time of the incident
Protocols and standards requirements:
• IEEE 802.1 AB LLDP
• IEEE 802.1p L2 Prioritization
• IEEE 802.1X Network Access Control
• IEEE 802.3x Flow Control
• IEEE 802.3z Gigabit Ethernet (1000Base-X) with QSA
• IEEE 802.1Q VLAN Tagging, Double VLAN Tagging, GVRP if enabled on storage array
• IEEE 802.3ac Frame Extensions for VLAN Tagging
• IETF RFC793 TCP
• IETF RFC1042 Ethernet Transmission
These features are typically present in certain classes of switches from switch vendors that are targeted at
data center environments. These switches may be described by switch vendors as “enterprise class”, “top of
rack” or “data center edge” offerings.
Please work with your Dell storage expert to determine whether your switch is suitable for use with an iSCSI
SAN solution.
25/100Gb iSCSI Switches (SC, SCv Series)
16 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
3.3.2 25/100Gb iSCSI Switches (SC, SCv Series) 25Gb and 100Gb iSCSI switches listed in this section are supported at Level 1 (as described previously) for
the listed switch firmware versions.
Note: With 25Gb, disable auto-negotiation with the copper break-out cables.
OEM Switch Model Protocol Switch Type Switch Firmware Switch Notes
Dell MX9116n iSCSI Converged 10.4(x) SCOS 7.2.x or later
Dell MX5108n iSCSI Converged 10.4(x) SCOS 7.2.x or later
Dell S4148U-ON iSCSI Converged 10.4(x) SCOS 7.2.x or later
Dell S4148x-ON iSCSI Ethernet 10.4(x) SCOS 7.2.x or later
Dell S4048x-ON iSCSI Ethernet 10.5(x) SCOS 7.3.x or later
Dell S4112x-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later
Dell S4128x-ON iSCSI Ethernet 10.5(x) SCOS 7.3.x or later
Dell S4248x-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later
Dell S5232F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later
Dell S5248F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later
Dell S5296F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later
Dell Z9264F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later
Dell Z9332F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later
Dell Z9100-ON iSCSI Converged 9.13(x) SCOS 7.3.x or later
1/10Gb Switches (PS Series)
17 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
3.3.3 1/10Gb Switches (PS Series) For PS Series arrays, switches listed in this section are supported at Level 1 (as described previously) for the
switch firmware versions listed and PS Series array operating system versions.
Note: Attaching 10GbE arrays to switches that are designed and provide predominately 1GbE ports (1GbE switches) is not supported due to the potential of performance limitations that could result in data-unavailable scenarios. By design, 1GbE switches typically do not have the resources to manage 10GbE edge traffic.
Note: PS6210/6610 and PS4210 can be attached to 1GbE switches via the switch’s 1GbE RJ-45 ports. In this mode, the array will operate at 1Gb only.
Vendor Model Type Switch FW Version
PS OS Switch Interconnect
vPC/VLT Stacking LAG
Arista 7050S Eth 4.17.0F 9.0.x N/A N/A L1
Arista 7280SR Eth 4.16.7FX-7500R 9.0.x N/A N/A L1
Brocade RX Eth 2.7x 5.0.2 N/A N/A L1
Brocade RX Eth 2.8.x 6.0.x N/A N/A L1
Brocade TurboIron 24X Eth 4.2.x 4.3.x N/A N/A L1
Brocade TurboIron 24X Eth 7.3.x L2 N/A N/A L2
Brocade VDX 6720 Conv 2.0.x 5.1.x N/A L3 L1
Brocade VDX 6720 Conv 5.0.x 7.0.x N/A L3 L1
Brocade VDX 6940 Conv 7.0.1 9.0.x N/A L3 L1
Cisco Catalyst 3750X-48T-L Eth 12.x 5.1.x N/A L1 L1
Cisco Catalyst 3750X-48T-L Eth 6.0.x N/A L1 L1
Cisco Catalyst 3750X-48T-L Eth 7.0.x N/A L1 L1
Cisco Catalyst 3750X-48T-L Eth 8.0.x N/A L1 L1
Cisco Catalyst 3850 Family Eth 3.07.04E 8.0.x N/A L1 L1
Cisco Catalyst 4948-10G Eth 12.2.x 4.3.x N/A N/A L1
Cisco Catalyst 4948-10G Eth 15.0.x 7.0.x N/A N/A L1
Cisco Catalyst 4948-10G Eth 8.0.x N/A L1 L1
Cisco Catalyst 4948-10G Eth 8.1.x N/A L1 L1
Cisco Catalyst 4948-10G Eth 9.0.x N/A N/A L1
Cisco Catalyst 4948E Eth 15.2.x 7.0.x N/A N/A L1
Cisco Catalyst 4948E Eth 15.2.x 8.1.x N/A N/A L1
Cisco Catalyst 4948E Eth 9.0.x N/A N/A L1
1/10Gb Switches (PS Series)
18 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Switch FW Version
PS OS Switch Interconnect
vPC/VLT Stacking LAG
Cisco Nexus 55xxUP Conv 5.2.x 6.0.x L1 N/A L1
Cisco Nexus 55xxUP Conv 6.0.x 6.0.x L1 N/A L1
Cisco Nexus 55xxUP Conv 7.0.x 7.0.x L1 N/A L1
Cisco Nexus 55xxUP Conv 8.0.x L1 L1 L1
Cisco Nexus 55xxUP Conv 7.1.x 8.1.x L1 N/A L1
Cisco Nexus 55xxUP Conv 7.2.x 9.0.x L1 N/A L1
Cisco Nexus 5648Q (no DCB) Eth 7.3(2)N1(1) 9.1 L1 NA L1
Cisco Nexus 6000 Family Conv 7.0.x 7.0.x L1 N/A L1
Cisco Nexus 6000 Family Conv 7.0.x 7.1.x L1 N/A L1
Cisco Nexus 6000 Family Conv 7.1.x 8.1.x L1 N/A L1
Cisco Nexus 6000 Family Conv 7.2.x 9.0.x L1 N/A L1
Cisco Nexus 7000 Family Conv 6.1.x 6.0.x L3 N/A L1
Cisco Nexus 7000 Family Conv 6.2.x 7.0.x L3 N/A L1
Cisco Nexus 7000 Family Conv 8.0.x N/A N/A L1
Cisco Nexus 7000 Family Conv 8.1.x N/A N/A L1
Cisco Nexus 7000 Family Conv 9.0.x L1 N/A L1
Cisco Nexus 9372PX (no DCB) Eth 7.0(3) I5(2) 9.1 L1 NA L1
Cisco Nexus 9500 Conv 7.0(3) 7.1.x L1 N/A L1
Cisco Nexus 9500 Conv 9.0.x L1 N/A L1
Dell Dell Networking N2000 Eth 6.0.x 7.0.x N/A L1 L1
Dell Dell Networking N2000 Eth 8.0.x N/A L1 L1
Dell Dell Networking N2000 Eth 6.2.x 8.1.x N/A L1 L1
Dell Dell Networking N2000 Eth 9.0.x L3 L1 L1
Dell Dell Networking N3000 Eth 6.0.x 7.0.x N/A L1 L1
Dell Dell Networking N3000 Eth 8.0.x N/A L1 L1
Dell Dell Networking N3000 Eth 6.2.x 8.1.x N/A L1 L1
Dell Dell Networking N3000 Eth 9.0.x L3 L1 L1
Dell Dell Networking N4000 Eth 6.0.x 7.0.x N/A L1 L1
Dell Dell Networking N4000 Eth 6.1.x 7.1.x N/A L1 L1
Dell Dell Networking N4000 Eth 6.1.x 8.0.x N/A L1 L1
Dell Dell Networking N4000 Eth 6.2.x 8.1.x N/A L1 L1
1/10Gb Switches (PS Series)
19 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Switch FW Version
PS OS Switch Interconnect
vPC/VLT Stacking LAG
Dell Dell Networking N4000 Eth 9.0.x L3 L1 L1
Dell Dell Networking S3000- ON Eth 9.8.x 7.1.x N/A L1 L1
Dell Dell Networking S3000- ON Eth 9.9.x 8.1.x L1 L1 L1
Dell Dell Networking S3000- ON Eth 9.0.x L1 L1 L1
Dell Dell Networking S3000- ON Eth 9.10.x 9.0.x L1 L1 L1
Dell Dell Networking S3000- ON Eth 10.3.1 9.0.x L1 L1 L1
Dell Dell Networking S3100 Eth 9.8.x 9.0.x L1 L1 L1
Dell Dell Networking S4000- ON Eth 9.8.x 7.1.x L1 L1 L1
Dell Dell Networking S4000- ON Eth 9.9.x 8.1.x L1 L1 L1
Dell Dell Networking S4000- ON Eth 9.0.x L1 L1 L1
Dell Dell Networking S4000- ON Eth 9.10.x 9.0.x L1 L1 L1
Dell Dell Networking S4000- ON Eth 10.3.1 9.1.x L1 L1 L1
Dell Dell Networking S4128F Conv 10.3.1E 9.1 L1 NA L1
Dell Dell Networking S4148F Conv 10.3.1E 9.1 L1 NA L1
Dell Dell Networking S4148T Conv 10.3.1E 9.1 L1 NA L1
Dell Dell Networking S4148U Conv 10.3.1E 9.1 L1 NA L1
Dell Dell Networking S4148FE Conv 10.3.1E 9.1 L1 NA L1
Dell Dell Networking S4248FB Conv 10.4.0E(R2) 9.1 L1 NA L1
Dell Dell Networking S4248FBL Conv 10.4.0E(R2) 9.1 L1 NA L1
Dell Dell Networking S5000 Conv 9.0.x 6.0.x L1 L1 L1
Dell Dell Networking S5000 Conv 7.0.x L1 L1 L1
Dell Dell Networking S5000 Conv 9.1.x 7.0.x L1 L1 L1
Dell Dell Networking S5000 Conv 8.0.x L1 L1 L1
Dell Dell Networking S5000 Conv 9.6.x 7.0.x L1 L1 L1
Dell Dell Networking S5000 Conv 9.7.x 8.0.x L1 L1 L1
Dell Dell Networking S5000 Conv 9.8.x 7.1.x L1 L1 L1
Dell Dell Networking S5000 Conv 9.9.x 8.1.x L1 L1 L1
Dell Dell Networking S5000 Conv 9.0.x L1 L1 L1
Dell Dell Networking S5000 Conv 9.10.x 9.0.x L1 L1 L1
Dell Dell Networking S6000 Eth 9.0.x 6.0.x L1 L1 L1
Dell Dell Networking S6000 Eth 9.3.x 7.0.x L1 L1 L1
1/10Gb Switches (PS Series)
20 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Switch FW Version
PS OS Switch Interconnect
vPC/VLT Stacking LAG
Dell Dell Networking S6000 Eth 9.4.x 7.0.x L1 L1 L1
Dell Dell Networking S6000 Eth 9.6.x 7.0.x L1 L1 L1
Dell Dell Networking S6000 Eth 8.0.x L1 L1 L1
Dell Dell Networking S6000 Eth 9.7.x 7.1.x L1 L1 L1
Dell Dell Networking S6000 Eth 9.8.x 7.1.x L1 L1 L1
Dell Dell Networking S6000 Eth 9.9.x 8.1.x L1 L1 L1
Dell Dell Networking S6000 Eth 9.0.x L1 L1 L1
Dell Dell Networking S6000 Eth 9.10.x 9.0.x L1 L1 L1
Dell Dell Networking S6010 Eth 9.10.x 9.0.x L1 L1 L1
Dell Dell Networking Z9000 Eth 9.3.x 7.0.x L1 L1 L1
Dell Dell Networking Z9000 Eth 9.4.x 7.0.x L1 L1 L1
Dell Dell Networking Z9000 Eth 9.7.x 7.1.x L1 L1 L1
Dell Dell Networking Z9000 Eth 9.8.x 7.1.x L1 L1 L1
Dell Dell Networking Z9000 Eth 9.9.x 8.1.x L1 L1 L1
Dell Dell Networking Z9000 Eth 9.0.x L1 L1 L1
Dell Dell Networking Z9000 Eth 9.10.x 9.0.x L1 L1 L1
Dell Dell Networking Z9500 Eth 9.5.x 7.0.x L1 L1 L1
Dell Dell Networking Z9500 Eth 9.7.x 7.1.x L1 L1 L1
Dell Dell Networking Z9500 Eth 8.0.x L1 L1 L1
Dell Dell Networking Z9500 Eth 9.0.x L1 L1 L1
Dell Dell Networking Z9500 Eth 9.8.x 7.1.x L1 L1 L1
Dell Dell Networking Z9500 Eth 9.9.x 8.1.x L1 L1 L1
Dell Dell Networking Z9500 Eth 9.0.x L1 L1 L1
Dell Dell Networking Z9500 Eth 9.10.x 9.0.x L1 L1 L1
Dell Dell Networking C-7000 Eth 7.7.x 4.3.x N/A N/A L1
Dell Dell Networking C-9000 Eth 9.9.x 8.1.x L3 N/A L1
Dell Dell Networking C-9000 Eth 9.0.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 8.3.x 5.2.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 6.0.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 9.2.x 6.0.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 7.0.x L1 L1 L1
1/10Gb Switches (PS Series)
21 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Switch FW Version
PS OS Switch Interconnect
vPC/VLT Stacking LAG
Dell Dell Networking MXL/IOA Eth 9.4.x 7.0.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 9.6.x 7.0.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 8.0.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 9.7.x 7.1.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 9.8.x 7.1.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 9.9.x 8.1.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 9.0.x L1 L1 L1
Dell Dell Networking MXL/IOA Eth 9.10.x 9.0.x L1 L1 L1
Dell Dell Networking S4810 Eth 8.3.x 5.1.x N/A L1 L1
Dell Dell Networking S4810 Eth 8.3.x 5.2.x N/A L1 L1
Dell Dell Networking S4810 Eth 6.0.x N/A L1 L1
Dell Dell Networking S4810 Eth 9.1.x 6.0.x L1 L1 L1
Dell Dell Networking S4810 Eth 9.2.x 7.0.x L1 L1 L1
Dell Dell Networking S4810 Eth 9.4.x 7.0.x L1 L1 L1
Dell Dell Networking S4810 Eth 9.5.x 8.0.x L1 L1 L1
Dell Dell Networking S4810 Eth 9.6.x 7.0.x L1 L1 L1
Dell Dell Networking S4810 Eth 7.1.x L1 L1 L1
Dell Dell Networking S4810 Eth 9.7.x 7.1.x L1 L1 L1
Dell Dell Networking S4810 Eth 9.8.x 7.1.x L1 L1 L1
Dell Dell Networking S4810 Eth 9.9.x 8.1.x L1 L1 L1
Dell Dell Networking S4810 Eth 9.0.x L1 L1 L1
Dell Dell Networking S4810 Eth 9.10.x 9.0.x L1 L1 L1
Dell Dell Networking S4820T Eth 8.3.x 6.0.x L1 L1 L1
Dell Dell Networking S4820T Eth 9.2.x 7.0.x L1 L1 L1
Dell Dell Networking S4820T Eth 8.0.x L1 L1 L1
Dell Dell Networking S4820T Eth 9.4.x 7.0.x L1 L1 L1
Dell Dell Networking S4820T Eth 9.6.x 7.0.x L1 L1 L1
Dell Dell Networking S4820T Eth 9.7.x 7.1.x L1 L1 L1
Dell Dell Networking S4820T Eth 9.8.x 7.1.x L1 L1 L1
Dell Dell Networking S4820T Eth 9.9.x 8.1.x L1 L1 L1
Dell Dell Networking S4820T Eth 9.0.x L1 L1 L1
1/10Gb Switches (PS Series)
22 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Switch FW Version
PS OS Switch Interconnect
vPC/VLT Stacking LAG
Dell Dell Networking S4820T Eth 9.10.x 9.0.x L1 L1 L1
Dell Dell Networking S25N/S50N Eth 7.7.x 4.3.x N/A L1 L1
Dell Dell Networking S25N/S50N Eth 8.4.x 5.1.x N/A L1 L1
Dell Dell Networking S25N/S50N Eth 6.0.x N/A L1 L1
Dell Dell Networking S25N/S50N Eth 7.0.x N/A L1 L1
Dell Dell Networking S55 Eth 8.3.x 5.1.x N/A L1 L1
Dell Dell Networking S55 Eth 6.0.x N/A L1 L1
Dell Dell Networking S55 Eth 7.0.x N/A L1 L1
Dell Dell Networking S55 Eth 8.0.x N/A L1 L1
Dell Dell Networking S55 Eth 9.0.x L1 L1 L1
Dell Dell Networking S60 Eth 8.3.x 5.1.x N/A L1 L1
Dell Dell Networking S60 Eth 6.0.x N/A L1 L1
Dell Dell Networking S60 Eth 7.0.x N/A L1 L1
Dell Dell Networking S60 Eth 8.0.x N/A L1 L1
Dell Dell Networking S60 Eth 8.3.x 8.1.x N/A L1 L1
Dell Dell Networking S60 Eth 9.0.x L1 L1 L1
Dell PowerConnect 70xx Family Eth 4.1.x 4.3.x N/A L1 L1
Dell PowerConnect 70xx Family Eth 4.2.x 6.0.x N/A L1 L1
Dell PowerConnect 70xx Family Eth 5.0.x 6.0.x N/A L1 L1
Dell PowerConnect 70xx Family Eth 5.1.x 6.0.x N/A L1 L1
Dell PowerConnect 70xx Family Eth 7.0.x N/A L1 L1
Dell PowerConnect 70xx Family Eth 9.0.x N/A L1 L1
Dell PowerConnect 81xx Family Eth 5.0.x 5.2.x N/A L1 L1
Dell PowerConnect 81xx Family Eth 6.0.x N/A L1 L1
Dell PowerConnect 81xx Family Eth 5.1.x 6.0.x N/A L1 L1
Dell PowerConnect 81xx Family Eth 7.0.x N/A L1 L1
Dell PowerConnect 81xx Family Eth 6.0.x 7.0.x N/A L1 L1
Dell PowerConnect M6348 Eth 3.1.x 4.3.x N/A L1 L1
Dell PowerConnect M6348 Eth 4.2.x 6.0.x N/A L1 L1
Dell PowerConnect M6348 Eth 5.0.x 6.0.x N/A L1 L1
Dell PowerConnect M6348 Eth 5.1.x 6.0.x N/A L1 L1
1/10Gb Switches (PS Series)
23 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Switch FW Version
PS OS Switch Interconnect
vPC/VLT Stacking LAG
Dell PowerConnect M6348 Eth 7.0.x N/A L1 L1
Dell PowerConnect M6348 Eth 8.0.x N/A L1 L1
Dell PowerConnect M8428-k Eth 6.3.x 6.0.x N/A L3 L1
Dell PowerConnect M8428-k Eth 7.0.x N/A L3 L1
Dell PowerConnect M8428-k Eth 8.0.x N/A L1 L1
Dell PowerEdge IO Aggregator Eth 8.3.x 6.0.x N/A L1 L1
Dell PowerEdge IO Aggregator Eth 9.2.x 6.0.x L1 L1 L1
Dell PowerEdge IO Aggregator Eth 7.0.x L1 L1 L1
Dell PowerEdge IO Aggregator Eth 9.6.x 7.0.x L1 L1 L1
Dell PowerEdge IO Aggregator Eth 8.0.x L1 L1 L1
Huawei CE6850 Eth 8.100 9.1.x L1 NA L1
HP 5900AF-48G Eth 7.1.x 7.0.x N/A L3 L1
HP 5900AF-48G Eth 8.0.x N/A L1 L1
iSCSI over DCB support (SC, SCv and PS Series)
24 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
3.4 iSCSI over DCB support (SC, SCv and PS Series) The following table indicates switches that have been tested with each array family’s native iSCSI over DCB
features.
SC Series arrays, with the release of SC Operating System (SCOS) 7.0 now support iSCSI over DCB. With
this support, the SC series supports the following DCB standards:
• IEEE 802.1Qbb – Priority Flow Control
• IEEE 802.1Qaz – Enhanced Transmission Selection
• IEEE 802.1Qaz – Data Center Bridging Exchange Protocol (IEEE DCBx)
Note: SC Series arrays do not support pre-IEEE DCBx standards such as converged enhanced Ethernet (CEE) or data center Ethernet (DCE) for iSCSI over DCB functionality. Switches that are listed in the table below that only support these pre-IEEE versions are designated as “L4” indicating there is “No Support”. Note: SC Series iSCSI over DCB is supported on controllers using the Chelsio T5xxx iSCSI Adapters at this time.
Vendor Model Type Switch FW Version
PS OS
SC OS
Notes
Cisco Nexus 55xxUP Conv 7.0.x 7.0.x
L4 Cisco Nexus switches only support CEE version of DCBx and are not compatible with SC Series Array iSCSI over DCB functionality
Cisco Nexus 55xxUP 8.0.x
L4
Cisco Nexus 55xxUP 7.1.x 8.1.x
L4
Cisco Nexus 6000 Family Conv 7.0.x 7.0.x
L4
Cisco Nexus 6000 Family 7.1.x
L4
Cisco Nexus 6000 Family 7.1.x 8.1.x
L4
Dell Dell Networking N4000 Eth 6.0.x 7.0.x
L4 Switches based on DNOS 6.x prior to 6.3.0.3 only support CEE version of DCBx and are not compatible with SC Series Array iSCSI over DCB functionality
Dell Dell Networking N4000 6.1.x 7.1.x
L4
Dell Dell Networking N4000 8.0.x
L4
Dell Dell Networking N4000 6.2.x 8.1.x
L4
Dell Dell Networking N4000 6.3.x 8.0.x
7.0.x SC DCB support requires DNOS 6.3.0.3 or later
Dell Dell Networking S4000-ON Eth 9.8.x 7.1.x
L3
iSCSI over DCB support (SC, SCv and PS Series)
25 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Switch FW Version
PS OS
SC OS
Notes
Dell Dell Networking S4000-ON 9.9.x 8.1.x
7.0.x
Dell Dell Networking S4000-ON 9.10.x 8.1.x
7.0.x
Dell Dell Networking S4000-ON Conv 10.3.1 9.1 7.2.1
Dell Dell Networking S4128F Conv 10.3.1E 9.1 7.2.1
Dell Dell Networking S4148F Conv 10.3.1E 9.1 7.2.1
Dell Dell Networking S4128T Conv 10.3.1E 9.1 7.2.1
Dell Dell Networking S4148T Conv 10.3.1E 9.1 7.2.1
Dell Dell Networking S4148U Conv 10.3.1E 9.1 7.2.1
Dell Dell Networking S4148FE Conv 10.3.1E 9.1 7.2.1
Dell Dell Networking S4248FB Conv 10.4.0E(R2) 9.1 7.2.1
Dell Dell Networking S4248FBL Conv 10.4.0E(R2) 9.1 7.2.1
Dell DN S5000 Conv 9.0.x 6.0.x
L3
Dell DN S5000 7.0.x
L3
Dell DN S5000 Conv 9.1.x 7.0.x
L3
Dell DN S5000 9.1.x 8.0.x
L3
Dell DN S5000 9.6.x 7.0.x
L3
Dell DN S5000 9.7.x 8.0.x
L3
Dell DN S5000 9.8.x 7.1.x
L3
Dell DN S5000 9.9.x 8.1.x
7.0.x
Dell DN S5000 9.10.x 8.1.x
7.0.x
Dell Dell Networking S5048F Conv Only
9.12.1 9.1 7.2.1 LLFC is not supported.
Dell Dell Networking S5048F Conv Only
9.12.1 9.1 7.2.1 LLFC is not supported.
Dell Dell Networking S6000 Eth 9.0.x 6.0.x
L3
iSCSI over DCB support (SC, SCv and PS Series)
26 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Switch FW Version
PS OS
SC OS
Notes
Dell Dell Networking S6000 9.3.x 7.0.x
L3
Dell Dell Networking S6000 9.4.x 7.0.x
L3
Dell Dell Networking S6000 9.6.x 7.0.x
L3
Dell Dell Networking S6000 8.0.x
L3
Dell Dell Networking S6000 9.7.x 7.1.x
L3
Dell Dell Networking S6000 9.8.x 7.1.x
L3
Dell Dell Networking S6000 9.9.x 8.1.x
7.0.x
Dell Dell Networking S6000 9.10.x 8.1.x
7.0.x
Dell Dell Networking S6100 Conv 9.10.x 8.1.x
7.0.x
Dell Dell Networking Z9000 Eth 9.7.x 7.1.x
L3
Dell Dell Networking Z9000 9.8.x 7.1.x
L3
Dell Dell Networking Z9000 9.9.x 8.1.x
7.0.x
Dell Dell Networking Z9000 9.10.x 8.1.x
7.0.x
Dell Z9100 Conv 9.10.x 8.1.x
7.0.x
Dell Dell Networking Z9500 Eth 9.7.x 7.1.x
L3
Dell Dell Networking Z9500 8.0.x
L3
Dell Dell Networking Z9500 9.8.x 7.1.x
L3
Dell Dell Networking Z9500 9.9.x 8.1.x
7.0.x
Dell Dell Networking Z9500 9.10.x 8.1.x
7.0.x
Dell Dell Networking C-9000 Eth 9.9.x 8.1.x
7.0.x All SAN ports must be 10GbE and DCB enabled
Dell Dell Networking C-9000 9.10.x 8.1.x
7.0.x
Dell Dell Networking MXL/IOA Eth 9.2.x 6.0.x
L3
Dell Dell Networking MXL/IOA 7.0.x
L3
Dell Dell Networking MXL/IOA 9.4.x 7.0.x
L3
Dell Dell Networking MXL/IOA 9.6.x 7.0.x
L3
Dell Dell Networking MXL/IOA 8.0.x
L3
Dell Dell Networking MXL/IOA 9.7.x 7.1.x
L3
Dell Dell Networking MXL/IOA 9.8.x 7.1.x
L3
iSCSI over DCB support (SC, SCv and PS Series)
27 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Switch FW Version
PS OS
SC OS
Notes
Dell Dell Networking MXL/IOA 9.9.x 8.1.x
7.0.x
Dell Dell Networking MXL/IOA 9.10.x 8.1.x
7.0.x
Dell Dell Networking S4810 Eth 8.3.x 5.2.x
L3
Dell Dell Networking S4810 6.0.x
L3
Dell Dell Networking S4810 9.1.x 6.0.x
L3
Dell Dell Networking S4810 9.2.x 7.0.x
L3
Dell Dell Networking S4810 9.4.x 7.0.x
L3
Dell Dell Networking S4810 9.5.x 8.0.x
L3
Dell Dell Networking S4810 9.6.x 7.0.x
L3
Dell Dell Networking S4810 7.1.x
L3
Dell Dell Networking S4810 9.7.x 7.1.x
L3
Dell Dell Networking S4810 9.8.x 7.1.x
L3
Dell Dell Networking S4810 9.9.x 8.1.x
7.0.x
Dell Dell Networking S4810 9.10.x 8.1.x
7.0.x
Dell Dell Networking S4820T Eth 8.3.x 6.0.x
L3
Dell Dell Networking S4820T 9.2.x 7.0.x
L3
Dell Dell Networking S4820T 8.0.x
L3
Dell Dell Networking S4820T 9.4.x 7.0.x
L3
Dell Dell Networking S4820T 9.6.x 7.0.x
L3
Dell Dell Networking S4820T 9.7.x 7.1.x
L3
Dell Dell Networking S4820T 9.8.x 7.1.x
L3
iSCSI over DCB support (SC, SCv and PS Series)
28 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Switch FW Version
PS OS
SC OS
Notes
Dell Dell Networking S4820T 9.9.x 8.1.x
7.0.x
Dell Dell Networking S4820T 9.10.x 8.1.x
7.0.x
Dell PowerConnect 81xx Family Eth 5.0.x 5.2.x
L4 Switches based on DNOS 6.x prior to 6.3.0.3 only support CEE version of DCBx and are not compatible with SC Series Array iSCSI over DCB functionality
Dell PowerConnect 81xx Family 6.0.x
L4
Dell PowerConnect 81xx Family 5.1.x 6.0.x
L4
Dell PowerConnect 81xx Family 7.0.x
L4
Dell PowerConnect 81xx Family 6.0.x 7.0.x
L4 PowerConnect 81xx switches with DNOS 6.x or later are considered Dell Networking N4000 switches
Dell PowerEdge IO Aggregator Eth 9.2.x 6.0.x
L3
Dell PowerEdge IO Aggregator 7.0.x
L3
Dell PowerEdge IO Aggregator 9.6.x 7.0.x
L3
Dell PowerEdge IO Aggregator 8.0.x
L3
Dell PowerEdge IO Aggregator 9.7.x 7.1.x
L3
Dell PowerEdge IO Aggregator 9.8.x 7.1.x
L3
Dell PowerEdge IO Aggregator 9.9.x 8.1.x
7.0.x
Dell PowerEdge IO Aggregator 9.10.x 8.1.x
7.0.x
Host connectivity
29 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4 Host connectivity Configurations listed in this section are supported at Level 1 for the listed Adapter/NIC operating
system/driver/firmware and array firmware combinations.
The model SCv2000, SCv2020, and SCv2080 only support a subset of host operating systems. These are:
• Citrix XenServer (now known as Hypervisor),
• Microsoft Windows Server,
• Novell SLES
• RHEL
• VMWare ESXi
All other supported Storage Center models support all OS’s and adapters listed in the following table.
Boot from SAN is tested with some OS-adapter combinations. If the BFS column has a “Y”, then Boot from
SAN was successfully tested with this OS-Adapter combination. If the BFS column has an “N”, then Boot
from SAN was not tested and is supported as Level 3, Commercially reasonable effort as described in 2.3
above. If the BFS column has a “Not Supported”, then Boot from SAN has not been tested and is not
supported, as described in section 2.4 above.
Unless otherwise noted, the OS-provided native multipath IO functionality for all validations listed.
4.1 Required Adapter and Server OS Settings Server host bus adapters and converged network adapters (hereafter called adapters) require specific
configuration settings in order to maintain IO during Storage Center controller failovers and network/fabric
path failovers. Some of these settings are identical for all supported operating systems and others vary by
operating system. Refer to Appendix A, Required Adapter and OS Settings.
Fibre Channel Adapters (SC and SCv Series)
30 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4.2 Fibre Channel Adapters (SC and SCv Series)
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 6.7.x No
Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 7.1.x No
Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 7.2.x No
Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 7.3.x No
Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 7.4.x No Multipath supported with SCOS 7.4.5 or later
Citrix XenServer 6.5 Emulex LPe1200x/LPe1205 10.2.340.0 5.13a11 2.02A1 7.1.x Yes
Citrix XenServer 6.5 Emulex LPe1200x/LPe1205 10.2.340.0 5.13a3 2.01A12 6.7.x Yes
Citrix XenServer 6.5 QLogic QxE256x 8.07.00.09.66.5-k 3.27 7.04.00 6.7.x Yes
Citrix XenServer 6.5 QLogic QxE256x 8.07.00.09.66.5-k 3.29 8.01.02 7.1.x Yes
Citrix XenServer 7.0 Emulex LPe1200x/LPe1205 11.0.0.12 5.13a11 2.02A1 7.1.x Yes
Citrix XenServer 7.0 Emulex LPe1200x/LPe1205 11.0.0.12 5.13a11 2.02A1 7.2.x Yes
Citrix XenServer 7.0 Emulex LPe1200x/LPe1205 11.1.210.1 5.13a11 2.02A1 7.2.x Yes
Citrix XenServer 7.0 QLogic QxE256x 8.07.00.33.77.0-k 3.29 8.01.02 7.1.x Yes
Citrix XenServer 7.0 QLogic QxE256x 8.07.00.33.77.0-k 3.29 8.01.02 7.2.x Yes
Citrix XenServer 7.0 QLogic QxE256x 8.07.00.41.77.1-k 3.29 8.01.02 7.2.x Yes
Citrix XenServer 7.1 Emulex LPe1200x/LPe1205 11.0.0.12 5.13a11 2.02A1 7.2.x Yes
Citrix XenServer 7.1 QLogic QxE256x 8.07.00.33.77.0-k 3.29 8.01.02 7.2.x Yes
Citrix XenServer 7.2 Emulex LPe1200x/LPe1205 11.1.210.1 11.40a6 2.02a3 7.3.x Yes
Citrix XenServer 7.2 Emulex LPe1200x/LPe1205 11.1.210.1 5.13a11 2.02A1 7.2.x Yes
Citrix XenServer 7.2 QLogic QxE256x 8.07.00.41.77.1-k 3.29 8.01.02 7.2.x Yes
Citrix XenServer 7.2 QLogic QxE256x 8.07.00.41.77.1-k 3.43 8.07.00 7.3.x Yes
Citrix XenServer 7.6 Emulex LPe1200x/LPe1205 11.1.210.1 12.00a4 2.02A4 7.3.x Yes
Citrix XenServer 7.6 Emulex LPe1200x/LPe1205 11.1.210.1 12.00a4 2.02A4 7.4.x Yes
Citrix XenServer 7.6 QLogic QxE256x 8.08.00.07.71.0-k 3.43 8.08.01 7.3.x Yes
Fibre Channel Adapters (SC and SCv Series)
31 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Citrix XenServer 7.6 QLogic QxE256x 8.08.00.07.71.0-k 3.43 8.08.01 7.4.x Yes
Citrix Hypervisor (XenServer) 8.0
Emulex LPe1200x/LPe1205 12.0.0.10 12.00a4 2.02A4 7.3.x Yes
Citrix Hypervisor (XenServer) 8.0
Emulex LPe1200x/LPe1205 12.0.0.10 12.00a4 2.02A4 7.4.x Yes
Citrix Hypervisor (XenServer) 8.0
QLogic QxE256x 10.00.00.11.80.0-k 3.43 8.08.01 7.3.x Yes
Citrix Hypervisor (XenServer) 8.0
QLogic QxE256x 10.00.00.11.80.0-k 3.43 8.08.01 7.4.x Yes
HP HP-UX 11iv3 HP AB379A B.11.31.1705 1.05 4.00.070 7.3.x Yes
HP HP-UX 11iv3 HP AB379A B.11.31.1705 1.05 4.00.070 7.4.x Yes
HP HP-UX 11iv3 HP AD194 B.11.31.1705 1.05 4.00.070 6.7.x Yes
HP HP-UX 11iv3 HP AH401A B.11.31.1009 2.22 5.03.15 6.7.x Yes
HP HP-UX 11iv3 HP AH401A B.11.31.1009 2.22 5.03.15 7.1.x Yes
HP HP-UX 11iv3 HP AH401A B.11.31.1009 2.22 5.03.15 7.2.x Yes
HP HP-UX 11iv3 HP AH401A B.11.31.1009 2.22 5.03.15 7.3.x Yes
HP HP-UX 11iv3 HP AH401A B.11.31.1009 2.22 5.03.15 7.4.x Yes
HP HP-UX 11iv3 HP AH401A B.11.31.1705 2.22 5.03.15 6.7.x Yes
HP HP-UX 11iv3 HP AH401A B.11.31.1705 2.22 5.03.15 7.3.x Yes
HP HP-UX 11iv3 HP AH401A B.11.31.1705 2.22 5.03.15 7.4.x Yes
HP HP-UX 11iv3 HP AH403A B.11.31.1708 UU11.40A9 2.03X14 6.7.x Yes
HP HP-UX 11iv3 HP AH403A B.11.31.1708 UU11.40A9 2.03X14 7.3.x Yes
HP HP-UX 11iv3 HP AH403A B.11.31.1708 UU11.40A9 2.03X14 7.4.x Yes
HP HP-UX 11iv3 HP AT094A B.11.31.1708 UU11.40A9 2.03X14 6.7.x Yes
HP HP-UX 11iv3 HP AT094A B.11.31.1708 UU11.40A9 2.03X14 7.3.x Yes
HP HP-UX 11iv3 HP AT094A B.11.31.1708 UU11.40A9 2.03X14 7.4.x Yes
HP OpenVMS 8.4 HP AD194 2.05 - 4.04.004 7.3.x Yes
HP OpenVMS 8.4 HP AD194 2.05 - 4.04.004 7.4.x Yes
HP OpenVMS 8.4 HP FCA2354 2.05 - 4.04.004 6.7.x Yes
HP OpenVMS 8.4 HP FCA2354 2.05 - 4.04.004 7.1.x Yes
Fibre Channel Adapters (SC and SCv Series)
32 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
HP OpenVMS 8.4 HP FCA2354 2.05 - 4.04.004 7.2.x Yes
IBM AIX 6.1 IBM 577D 6.1.7.0 3.10X2 2.02X7 7.1.x Yes Tested with Multipath driver MPAIX03.00.00.007
IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 6.7.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 7.1.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 7.2.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 7.3.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 7.4.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 1.1.58.4 7.2.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 1.1.58.4 7.3.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 2.02X7 6.7.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 2.02X7 7.1.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 11.2.211.21 7.3.x Yes Tested with Multipath driver MPAIX03.00.02.005
Fibre Channel Adapters (SC and SCv Series)
33 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 11.2.211.21 7.4.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 7.1 IBM 577D 7.1.0.22 3.10X2 2.02X7 7.1.x Yes Tested with Multipath driver MPAIX03.00.00.007
IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 6.7.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 7.1.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 7.2.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 7.3.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 7.4.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 1.1.58.4 7.2.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 1.1.58.4 7.3.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 2.02X7 6.7.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 2.02X7 7.1.x Yes Tested with Multipath driver MPAIX03.00.01.006
Fibre Channel Adapters (SC and SCv Series)
34 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 11.2.211.21 7.3.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 11.2.211.21 7.4.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 6.7.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 7.1.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 7.2.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 7.3.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 7.4.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 1.1.58.4 7.2.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 1.1.58.4 7.3.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 2.02X7 6.7.x Yes Tested with Multipath driver MPAIX03.00.01.006
IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 2.02X7 7.1.x Yes Tested with Multipath driver MPAIX03.00.01.006
Fibre Channel Adapters (SC and SCv Series)
35 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 11.2.211.21 7.3.x Yes Tested with Multipath driver MPAIX03.00.02.005
IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 11.2.211.21 7.4.x Yes Tested with Multipath driver MPAIX03.00.02.005
Microsoft 2008 Windows Server R2 SP1
Cisco VIC-13xx 2.1.0.34 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 10.6.114.0 6.03X1 2.01A12 6.7.x Yes Dell fw kit: 01.06.01
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 10.6.114.0 6.03X1 2.01A12 7.1.x Yes Dell fw kit: 01.06.01
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 11.0.247.0 5.12a11 2.01A12 7.2.x Yes
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 11.0.247.0 7.00x1 2.01A12 7.1.x Yes Dell fw kit: 02.00.04
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 11.0.247.0 7.00x1 2.01A12 7.2.x Yes Dell fw kit: 02.00.04
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 11.0.247.0 7.00x1 2.02A1 6.7.x Yes Dell fw kit: 02.00.04
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 11.0.247.0 7.00x1 2.02A1 7.2.x Yes Dell fw kit: 02.00.04
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 11.2.124.0 11.40a6 2.02a3 7.3.x Yes
Fibre Channel Adapters (SC and SCv Series)
36 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 11.2.124.0 5.12a11 2.02a3 7.2.x Yes
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 11.2.124.0 6.03X1 2.02a3 7.2.x Yes Dell fw kit: 02.01.01*
Microsoft 2008 Windows Server R2 SP1
Emulex LPe1200x/LPe1205 11.2.124.0 6.03X1 2.02a3 7.3.x Yes Dell fw kit: 02.01.01*
Microsoft 2008 Windows Server R2 SP1
Emulex LPx1500x/LPx1600x 10.4.246.0 10.4.255.16 10.4.255.16 6.7.x Yes
Microsoft 2008 Windows Server R2 SP1
Emulex LPx1500x/LPx1600x 10.6.114.0 10.6.144.21 10.6.144.21 7.1.x Yes
Microsoft 2008 Windows Server R2 SP1
Emulex LPx1500x/LPx1600x 11.0.247.0 11.1.38.61 11.1.38.61 7.1.x Yes
Microsoft 2008 Windows Server R2 SP1
Emulex LPx1500x/LPx1600x 11.0.247.0 11.1.38.61 11.1.38.61 7.2.x Yes
Microsoft 2008 Windows Server R2 SP1
Emulex LPx1500x/LPx1600x 11.2.124.0 11.4.142.23 11.4.142.23 7.2.x Yes
Microsoft 2008 Windows Server R2 SP1
Emulex LPx1500x/LPx1600x 11.2.124.0 11.4.142.23 11.4.142.23 7.3.x Yes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE256x 9.1.13.20 3.27 7.04.00 6.7.x Yes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE256x 9.1.15.21 3.29 8.01.02 7.1.x Yes
Fibre Channel Adapters (SC and SCv Series)
37 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.1.x Yes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.2.x Yes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE256x 9.2.3.20 3.29 8.02.00 7.2.x Yes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.2.x Yes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.3.x Yes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE257x 9.1.13.20 3.24 7.04.00 6.7.x Yes Dell fw kit: 3.22.00
Microsoft 2008 Windows Server R2 SP1
QLogic QxE257x 9.1.15.21 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.22.07
Microsoft 2008 Windows Server R2 SP1
QLogic QxE257x 9.1.8.6 3.31 4.06.01 6.7.x Yes Dell fw kit: 03.22.08
Microsoft 2008 Windows Server R2 SP1
QLogic QxE257x 9.1.8.6 3.31 4.06.01 7.1.x Yes Dell fw kit: 03.22.08
Microsoft 2008 Windows Server R2 SP1
QLogic QxE257x 9.1.8.6 3.31 4.06.01 7.2.x Yes Dell fw kit: 03.22.08
Microsoft 2008 Windows Server R2 SP1
QLogic QxE257x 9.2.3.20 3.4 8.05.00 7.2.x Yes Dell fw kit: 09.00.03
Fibre Channel Adapters (SC and SCv Series)
38 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE257x 9.2.3.20 3.4 8.05.00 7.3.x Yes Dell fw kit: 09.00.03
Microsoft 2008 Windows Server R2 SP1
QLogic QxE266x 9.1.13.20 - 8.00.00 6.7.x No
Microsoft 2008 Windows Server R2 SP1
QLogic QxE266x 9.1.15.21 - 8.01.02 7.1.x No
Microsoft 2008 Windows Server R2 SP1
QLogic QxE266x 9.1.17.21 - 8.03.01 7.1.x No
Microsoft 2008 Windows Server R2 SP1
QLogic QxE266x 9.2.3.20 - 8.05.01 7.3.x No
Microsoft 2008 Windows Server R2 SP1
QLogic QxE266x 9.2.3.20 3.32 8.03.01 7.2.x Yes
Microsoft 2012 Windows Server
QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.2.x Yes
Microsoft 2012 Windows Server
QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.3.x Yes
Microsoft 2012 Windows Server
QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.4.x Yes
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.19 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.19 3.1(1h) 4.1(1f) 6.7.x Yes Cisco fw kit: 3.1(1h)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.19 3.1(1k) 4.1(1h) 6.7.x Yes Cisco fw kit: 3.1(1k)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.19 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.19 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
Fibre Channel Adapters (SC and SCv Series)
39 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.20 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.20 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.20 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.20 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.20 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.20 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.20 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.20 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.20 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d)
Microsoft 2012 Windows Server R2
Cisco VIC-13xx 2.4.0.20 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d)
Microsoft 2012 Windows Server R2
Emulex LPe1200x/LPe1205 10.6.114.0 5.13a11 2.02A1 6.7.x Yes
Microsoft 2012 Windows Server R2
Emulex LPe1200x/LPe1205 10.6.114.0 5.13a11 2.02A1 7.1.x Yes
Microsoft 2012 Windows Server R2
Emulex LPe1200x/LPe1205 11.0.247.0 7.00.a2 2.02A1 7.1.x Yes
Microsoft 2012 Windows Server R2
Emulex LPe1200x/LPe1205 11.0.247.0 7.00.a2 2.02A1 7.2.x Yes
Microsoft 2012 Windows Server R2
Emulex LPe1200x/LPe1205 11.4.142.11 - 2.02a3 7.3.x No
Microsoft 2012 Windows Server R2
Emulex LPe1200x/LPe1205 11.4.142.11 - 2.02A4 7.3.x No
Microsoft 2012 Windows Server R2
Emulex LPe1200x/LPe1205 12.2.207.0 12.00a4 2.02A4 7.4.x Yes
Fibre Channel Adapters (SC and SCv Series)
40 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2012 Windows Server R2
Emulex LPe1200x/LPe1205 12.2.284.0 12.00a4 2.02A4 7.4.x Yes
Microsoft 2012 Windows Server R2
Emulex LPx1500x/LPx1600x 10.6.114.0 10.6.144.21 10.6.144.21 6.7.x Yes
Microsoft 2012 Windows Server R2
Emulex LPx1500x/LPx1600x 10.6.114.0 10.6.144.21 10.6.144.21 7.1.x Yes
Microsoft 2012 Windows Server R2
Emulex LPx1500x/LPx1600x 10.6.114.0 11.0.270.9 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.04
Microsoft 2012 Windows Server R2
Emulex LPx1500x/LPx1600x 10.6.114.0 11.0.270.9 11.0.270.2002 7.2.x Yes Dell fw kit: 02.00.04
Microsoft 2012 Windows Server R2
Emulex LPx1500x/LPx1600x 11.2.139.0 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01
Microsoft 2012 Windows Server R2
Emulex LPx1500x/LPx1600x 11.2.139.0 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01
Microsoft 2012 Windows Server R2
Emulex LPx1500x/LPx1600x 12.2.207.0 12.0.257.12 12.0.257.12 7.4.x Yes
Microsoft 2012 Windows Server R2
Emulex LPx1500x/LPx1600x 12.2.284.0 12.0.257.12 12.0.257.12 7.4.x Yes
Microsoft 2012 Windows Server R2
Emulex LPx3100x/LPx3200x 11.4.142.11 11.4.142.23 11.4.142.23 7.2.x Yes
Microsoft 2012 Windows Server R2
Emulex LPx3100x/LPx3200x 11.4.142.11 11.4.142.23 11.4.142.23 7.3.x Yes
Microsoft 2012 Windows Server R2
Emulex LPx3100x/LPx3200x 12.0.193.13 11.4.258.15 11.4.258.15 7.3.x Yes Dell fw kit: 2.03.02
Microsoft 2012 Windows Server R2
Emulex LPx3100x/LPx3200x 12.0.367.0 12.0.257.12 12.0.257.12 7.4.x Yes
Microsoft 2012 Windows Server R2
Emulex LPx3100x/LPx3200x 12.2.284.0 12.2.350.10 12.2.350.10 7.4.x Yes
Microsoft 2012 Windows Server R2
Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.2.x No
Microsoft 2012 Windows Server R2
Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.4.x No
Microsoft 2012 Windows Server R2
QLogic QxE256x 9.1.13.20 3.27 7.04.00 6.7.x Yes
Fibre Channel Adapters (SC and SCv Series)
41 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2012 Windows Server R2
QLogic QxE256x 9.1.15.21 3.29 8.01.02 7.1.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.1.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.2.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE256x 9.2.3.20 3.29 8.01.02 7.2.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.2.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.3.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE256x 9.2.9.20 3.43 8.01.02 7.3.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE256x 9.2.9.20 3.43 8.01.02 7.4.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.1.13.20 3.27 7.04.01 6.7.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.1.13.20 3.28 8.00.00 6.7.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.1.13.20 3.29 7.04.00 6.7.x Yes Dell fw kit: 3.11.18
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.1.15.21 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.11.25
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.1.17.21 3.32 8.03.01 7.1.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.1.17.21 3.32 8.03.01 7.2.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.1.18.20 3.44 8.03.01 7.1.x Yes Dell fw kit: 08.00.15
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.1.18.20 3.44 8.03.01 7.2.x Yes Dell fw kit: 08.00.15
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.2.3.20 3.32 8.03.01 7.2.x Yes
Fibre Channel Adapters (SC and SCv Series)
42 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.2.3.20 3.43 8.05.01 7.2.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.2.3.20 3.43 8.05.01 7.3.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.2.3.22 3.43 8.05.01 7.2.x Yes Dell fw kit: 09.00.06
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.2.3.22 3.43 8.05.01 7.3.x Yes Dell fw kit: 09.00.06
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.2.9.20 3.45 8.07.11 7.3.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE266x 9.2.9.20 3.45 8.07.11 7.4.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE269x 9.2.3.20 3.38 8.03.05 7.2.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.2.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.3.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE269x 9.2.9.20 3.62 8.07.80 7.3.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE269x 9.2.9.20 3.62 8.07.80 7.4.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE269x 9.2.9.20 3.62 14.07.05 7.3.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE274x 9.1.17.21 - 8.03.04 7.1.x No
Microsoft 2012 Windows Server R2
QLogic QxE274x 9.2.3.20 3.38 8.03.05 7.2.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.2.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.3.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE274x 9.2.9.20 3.62 8.07.80 7.3.x Yes
Fibre Channel Adapters (SC and SCv Series)
43 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2012 Windows Server R2
QLogic QxE274x 9.2.9.20 3.62 8.07.80 7.4.x Yes
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.7 2.2(8d) 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2(8d)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.7 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.7 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.8 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.8 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.8 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.8 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.8 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.8 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.8 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.0.0.8 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.1.0.11 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d)
Microsoft 2016 Windows Server
Cisco VIC-13xx 3.1.0.11 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d)
Microsoft 2016 Windows Server
Cisco VIC-14xx 3.1.0.11 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a)
Microsoft 2016 Windows Server
Cisco VIC-14xx 3.1.0.11 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a)
Microsoft 2016 Windows Server
Emulex LPx1500x/LPx1600x 11.0.247.0 11.0.270.2002 11.0.270.2002 6.7.x Yes
Fibre Channel Adapters (SC and SCv Series)
44 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2016 Windows Server
Emulex LPx1500x/LPx1600x 11.0.247.0 11.0.270.2002 11.0.270.2002 7.1.x Yes
Microsoft 2016 Windows Server
Emulex LPx1500x/LPx1600x 11.0.247.0 11.0.270.2002 11.0.270.2002 7.2.x Yes
Microsoft 2016 Windows Server
Emulex LPx3100x/LPx3200x 11.4.142.11 11.4.142.23 11.4.142.23 7.2.x Yes
Microsoft 2016 Windows Server
Emulex LPx3100x/LPx3200x 11.4.142.11 11.4.142.23 11.4.142.23 7.3.x Yes
Microsoft 2016 Windows Server
Emulex LPx3100x/LPx3200x 12.0.193.13 11.4.258.15 11.4.258.15 7.3.x Yes Dell fw kit: 2.03.02
Microsoft 2016 Windows Server
Emulex LPx3100x/LPx3200x 12.0.193.13 12.0.257.12 12.0.257.12 7.4.x Yes
Microsoft 2016 Windows Server
Emulex LPx3100x/LPx3200x 12.2.284.0 12.2.350.10 12.2.350.10 7.4.x Yes
Microsoft 2016 Windows Server
Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.3.x No
Microsoft 2016 Windows Server
Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.4.x No
Microsoft 2016 Windows Server
Emulex LPx3500x 12.2.284.0 - 12.2.350.12 7.4.x No
Microsoft 2016 Windows Server
QLogic QxE256x 9.1.17.21 3.29 8.01.02 6.7.x Yes
Microsoft 2016 Windows Server
QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.1.x Yes
Microsoft 2016 Windows Server
QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.2.x Yes
Microsoft 2016 Windows Server
QLogic QxE256x 9.2.3.20 3.29 8.01.02 7.2.x Yes
Microsoft 2016 Windows Server
QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.2.x Yes
Microsoft 2016 Windows Server
QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.3.x Yes
Microsoft 2016 Windows Server
QLogic QxE256x 9.2.9.20 3.43 8.01.02 7.4.x Yes
Fibre Channel Adapters (SC and SCv Series)
45 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2016 Windows Server
QLogic QxE266x 9.1.17.21 3.32 8.03.01 6.7.x Yes
Microsoft 2016 Windows Server
QLogic QxE266x 9.1.17.21 3.32 8.03.01 7.1.x Yes
Microsoft 2016 Windows Server
QLogic QxE266x 9.1.17.21 3.32 8.03.01 7.2.x Yes
Microsoft 2016 Windows Server
QLogic QxE266x 9.2.3.20 3.32 8.03.01 7.2.x Yes
Microsoft 2016 Windows Server
QLogic QxE266x 9.2.3.20 3.43 8.05.01 7.2.x Yes
Microsoft 2016 Windows Server
QLogic QxE266x 9.2.3.20 3.43 8.05.01 7.3.x Yes
Microsoft 2016 Windows Server
QLogic QxE266x 9.2.9.20 3.43 8.05.01 7.4.x Yes
Microsoft 2016 Windows Server
QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.2.x Yes
Microsoft 2016 Windows Server
QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.3.x Yes
Microsoft 2016 Windows Server
QLogic QxE269x 9.2.9.20 3.43 8.05.00 7.4.x Yes
Microsoft 2016 Windows Server
QLogic QxE269x 9.2.9.20 3.62 8.07.80 7.3.x Yes
Microsoft 2016 Windows Server
QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.2.x Yes
Microsoft 2016 Windows Server
QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.3.x Yes
Microsoft 2016 Windows Server
QLogic QxE274x 9.2.9.20 3.43 8.05.00 7.4.x Yes
Microsoft 2016 Windows Server
QLogic QxE274x 9.2.9.20 3.62 8.07.80 7.3.x Yes
Microsoft 2019 Windows Server
Cisco VIC-14xx 3.2.0.14 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a)
Microsoft 2019 Windows Server
Cisco VIC-14xx 3.2.0.14 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a)
Fibre Channel Adapters (SC and SCv Series)
46 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2019 Windows Server
Emulex LPe1200x/LPe1205 11.4.142.11 12.00a4 2.02A4 7.3.x Yes
Microsoft 2019 Windows Server
Emulex LPe1200x/LPe1205 12.0.367.0 12.00a4 2.02A4 7.4.x Yes
Microsoft 2019 Windows Server
Emulex LPe1200x/LPe1205 12.2.284.0 12.00a4 2.02A4 7.4.x Yes
Microsoft 2019 Windows Server
Emulex LPx1500x/LPx1600x 11.4.142.11 11.4.142.23 11.4.142.23 7.3.x Yes
Microsoft 2019 Windows Server
Emulex LPx1500x/LPx1600x 12.0.367.0 11.4.142.23 11.4.142.23 7.4.x Yes
Microsoft 2019 Windows Server
Emulex LPx1500x/LPx1600x 12.2.284.0 11.4.142.23 11.4.142.23 7.4.x Yes
Microsoft 2019 Windows Server
Emulex LPx3100x/LPx3200x 11.4.142.11 11.4.258.12 11.4.258.15 7.3.x Yes
Microsoft 2019 Windows Server
Emulex LPx3100x/LPx3200x 11.4.142.11 12.0.257.12 12.0.257.12 7.4.x Yes
Microsoft 2019 Windows Server
Emulex LPx3100x/LPx3200x 12.2.284.0 12.2.350.10 12.2.350.10 7.4.x Yes
Microsoft 2019 Windows Server
Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.3.x No
Microsoft 2019 Windows Server
Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.4.x No
Microsoft 2019 Windows Server
Emulex LPx3500x 12.2.284.0 - 12.2.350.12 7.4.x No
Microsoft 2019 Windows Server
QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.3.x Yes
Microsoft 2019 Windows Server
QLogic QxE256x 9.2.8.21 3.43 8.01.02 7.4.x Yes
Microsoft 2019 Windows Server
QLogic QxE266x 9.2.3.20 - 8.05.01 7.3.x No
Microsoft 2019 Windows Server
QLogic QxE266x 9.2.8.21 - 8.05.01 7.4.x No
Microsoft 2019 Windows Server
QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.3.x Yes
Fibre Channel Adapters (SC and SCv Series)
47 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2019 Windows Server
QLogic QxE269x 9.2.9.23 3.43 8.05.00 7.4.x Yes
Microsoft 2019 Windows Server
QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.3.x Yes
Microsoft 2019 Windows Server
QLogic QxE274x 9.2.9.23 3.43 8.05.00 7.4.x Yes
Novell SLES 11 SP3 QLogic QxE266x 8.04.00.13.11.3-k 3.28 8.00.00 6.7.x Yes
Novell SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.29 8.01.02 6.7.x Yes
Novell SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.29 8.01.02 7.1.x Yes
Novell SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.29 8.01.02 7.2.x Yes
Novell SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.32 8.03.01 7.2.x Yes
Novell SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.43 8.05.01 7.3.x Yes
Novell SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.45 8.07.11 7.3.x Yes
Novell SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.45 8.07.11 7.4.x Yes
Novell SLES 12 Emulex LPe1200x/LPe1205 10.2.8040.1 5.13a0 2.01A12 6.7.x Yes
Novell SLES 12 SP1 Emulex LPe1200x/LPe1205 10.5.0.2 5.13a11 2.02A1 6.7.x Yes
Novell SLES 12 SP1 Emulex LPe1200x/LPe1205 10.5.0.2 5.13a11 2.02A1 7.1.x Yes
Novell SLES 12 SP1 Emulex LPe1200x/LPe1205 10.5.0.2 5.13a11 2.02A1 7.2.x Yes
Novell SLES 12 SP1 Emulex LPe1200x/LPe1205 10.5.0.2 7.00a2 2.02A1 7.2.x Yes
Novell SLES 12 SP1 Emulex LPe1200x/LPe1205 11.1.0.1 5.13a11 2.02A1 7.2.x Yes
Novell SLES 12 SP1 Emulex LPe1200x/LPe1205 11.4.0.1 11.40a6 2.02a3 7.3.x Yes
Novell SLES 12 SP1 Emulex LPe1200x/LPe1205 11.4.0.5 12.00a4 2.02A4 7.3.x Yes
Novell SLES 12 SP1 Emulex LPe1200x/LPe1205 11.4.0.7-1 12.00a4 2.02A4 7.4.x Yes
Novell SLES 15 QLogic QxE266x 10.00.00.08-k 3.45 8.07.11 7.3.x Yes
Novell SLES 15 QLogic QxE266x 10.00.00.08-k 3.45 8.07.11 7.4.x Yes
Oracle Linux Server 6.x UEK
QLogic QxE266x 8.05.00.03.39.0-k 3.24 7.03.00 6.7.x Yes
Oracle Linux Server 7.x UEK
Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 6.7.x Yes
Oracle Linux Server 7.x UEK
Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.1.x Yes
Fibre Channel Adapters (SC and SCv Series)
48 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Oracle Linux Server 7.x UEK
Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.2.x Yes
Oracle Linux Server 7.x UEK
Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.3.x Yes
Oracle Linux Server 7.x UEK
Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.4.x Yes
Oracle Linux Server 7.x UEK
Emulex LPx3100x/LPx3200x 11.1.0.4 11.0.270.9 11.0.270.18 6.7.x Yes
Oracle Linux Server 7.x UEK
Emulex LPx3100x/LPx3200x 11.1.0.4 11.0.270.9 11.0.270.18 7.1.x Yes
Oracle Linux Server 7.x UEK
Emulex LPx3100x/LPx3200x 11.1.0.4 11.0.270.9 11.0.270.18 7.2.x Yes
Oracle Linux Server 7.x UEK
Emulex LPx3100x/LPx3200x 11.1.0.4 11.0.270.9 11.0.270.18 7.3.x Yes
Oracle Linux Server 7.x UEK
Emulex LPx3100x/LPx3200x 11.1.0.4 11.0.270.9 11.0.270.18 7.4.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE256x 8.07.00.16.39.0-k 3.24 7.05.00 6.7.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE256x 8.07.00.26.39.0-k 3.24 8.02.00 7.1.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE256x 8.07.00.38.40.0-k 3.29 8.01.02 6.7.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE256x 8.07.00.38.40.0-k 3.29 8.01.02 7.1.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE256x 8.07.00.38.40.0-k 3.29 8.01.02 7.2.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE256x 9.00.00.00.40.0-k 3.29 8.01.02 7.3.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE256x 9.00.00.00.40.0-k 3.29 8.01.02 7.4.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE266x 8.07.00.16.39.0-k 3.24 7.03.00 6.7.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE266x 8.07.00.26.39.0-k 3.24 7.03.00 7.1.x Yes
Fibre Channel Adapters (SC and SCv Series)
49 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Oracle Linux Server 7.x UEK
QLogic QxE266x 8.07.00.38.40.0-k 3.32 8.03.01 6.7.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE266x 8.07.00.38.40.0-k 3.32 8.03.01 7.1.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE266x 8.07.00.38.40.0-k 3.32 8.03.01 7.2.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE266x 9.00.00.00.40.0-k 3.32 8.03.01 7.3.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE266x 9.00.00.00.40.0-k 3.32 8.03.01 7.4.x Yes
Oracle Linux Server 7.x UEK
QLogic QxE269x 8.07.00.38.40.0-k 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06
Oracle Linux Server 7.x UEK
QLogic QxE269x 8.07.00.38.40.0-k 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06
Oracle Linux Server 7.x UEK
QLogic QxE269x 8.07.00.38.40.0-k 3.43 8.05.00 7.4.x Yes Dell fw kit: 09.00.06
Oracle Linux Server 7.x UEK
QLogic QxE274x 8.07.00.38.40.0-k 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06
Oracle Linux Server 7.x UEK
QLogic QxE274x 8.07.00.38.40.0-k 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06
Oracle Linux Server 7.x UEK
QLogic QxE274x 8.07.00.38.40.0-k 3.43 8.05.00 7.4.x Yes Dell fw kit: 09.00.06
Oracle OVM 3.3.1 QLogic QxE256x 8.07.00.16.39.0-k - 7.01.00 6.7.x No
Oracle OVM 3.3.1 QLogic QxE266x 8.07.00.16.39.0-k - 7.00.01 6.7.x No
Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 6.7.x Yes
Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.1.x Yes
Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.2.x Yes
Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.3.x Yes
Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.4.0.7 12.0.257.12 12.0.257.12 7.4.x Yes
Oracle OVM 3.4.x Emulex LPx3100x/LPx3200x 11.4.0.7 12.0.257.12 12.0.257.12 7.4.x Yes
Oracle OVM 3.4.x QLogic QxE256x 8.07.00.26.39.0-k - 7.01.00 7.1.x No
Oracle OVM 3.4.x QLogic QxE256x 8.07.00.38.40.0-k - 8.01.02 6.7.x No
Fibre Channel Adapters (SC and SCv Series)
50 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Oracle OVM 3.4.x QLogic QxE256x 8.07.00.38.40.0-k - 8.01.02 7.1.x No
Oracle OVM 3.4.x QLogic QxE256x 8.07.00.38.40.0-k - 8.01.02 7.2.x No
Oracle OVM 3.4.x QLogic QxE256x 8.07.00.38.40.0-k - 8.01.02 7.3.x No
Oracle OVM 3.4.x QLogic QxE256x 9.00.00.00.41.0-k1 3.45 8.07.11 7.4.x Yes
Oracle OVM 3.4.x QLogic QxE266x 8.07.00.26.39.0-k - 7.00.01 7.1.x No
Oracle OVM 3.4.x QLogic QxE266x 8.07.00.38.40.0-k - 8.03.01 6.7.x No
Oracle OVM 3.4.x QLogic QxE266x 8.07.00.38.40.0-k - 8.03.01 7.1.x No
Oracle OVM 3.4.x QLogic QxE266x 8.07.00.38.40.0-k - 8.03.01 7.2.x No
Oracle OVM 3.4.x QLogic QxE266x 8.07.00.38.40.0-k - 8.03.01 7.3.x No
Oracle OVM 3.4.x QLogic QxE266x 9.00.00.00.41.0-k1 3.45 8.07.11 7.4.x Yes
Oracle Solaris 10 SPARC
QLogic QxE256x 170516-5.06c 3.29 8.05.00 7.4.x Yes
Oracle Solaris 10 SPARC
QLogic QxE256x v20110825-3.06 3.27 7.04.00 6.7.x Yes
Oracle Solaris 10 SPARC
QLogic QxE256x v20110825-3.06 3.27 7.04.00 7.1.x Yes
Oracle Solaris 10 SPARC
QLogic QxE256x v20110825-3.06 3.27 7.04.00 7.2.x Yes
Oracle Solaris 10 SPARC
QLogic QxE256x v20110825-3.06 3.27 7.04.00 7.3.x Yes
Oracle Solaris 10 x86_64
QLogic QxE256x 170516-5.06c 3.43 8.05.00 7.4.x Yes
Oracle Solaris 10 x86_64
QLogic QxE256x v20110825-3.06 3.2 5.09.00 6.7.x Yes
Oracle Solaris 10 x86_64
QLogic QxE256x v20110825-3.06 3.2 5.09.00 7.1.x Yes
Oracle Solaris 10 x86_64
QLogic QxE256x v20110825-3.06 3.2 5.09.00 7.2.x Yes
Oracle Solaris 10 x86_64
QLogic QxE256x v20110825-3.06 3.2 5.09.00 7.3.x Yes
Oracle Solaris 11 SPARC
Emulex LPe16002-o 3.3.00.1 12.0.193.34 12.0.193.34 7.3.x Yes
Fibre Channel Adapters (SC and SCv Series)
51 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Oracle Solaris 11 SPARC
Emulex LPe16002-o 3.3.00.1 12.0.193.34 12.0.193.34 7.4.x Yes
Oracle Solaris 11 SPARC
QLogic QxE256x 171019-5.07 3.43 8.05.00 6.7.x Yes
Oracle Solaris 11 SPARC
QLogic QxE256x 171019-5.07 3.43 8.05.00 7.2.x Yes
Oracle Solaris 11 SPARC
QLogic QxE256x 171019-5.07 3.43 8.05.00 7.3.x Yes
Oracle Solaris 11 SPARC
QLogic QxE256x 171019-5.07 3.43 8.05.00 7.4.x Yes
Oracle Solaris 11 SPARC
QLogic QxE256x v20120717-4.01 3.27 7.04.00 6.7.x Yes
Oracle Solaris 11 SPARC
QLogic QxE256x v20120717-4.01 3.27 7.04.00 7.1.x Yes
Oracle Solaris 11 SPARC
QLogic QxE256x v20120717-4.01 3.27 7.04.00 7.2.x Yes
Oracle Solaris 11 SPARC
QLogic QxE256x v20120717-4.01 3.27 7.04.00 7.3.x Yes
Oracle Solaris 11 SPARC
QLogic QxE274x 171019-5.07 3.62 8.07.70 6.7.x Yes
Oracle Solaris 11 SPARC
QLogic QxE274x 171019-5.07 3.62 8.07.70 7.2.x Yes
Oracle Solaris 11 SPARC
QLogic QxE274x 171019-5.07 3.62 8.07.70 7.3.x Yes
Oracle Solaris 11 SPARC
QLogic QxE274x 171019-5.07 3.62 8.07.70 7.4.x Yes
Oracle Solaris 11 x86_64
Emulex LPe1200x/LPe1205 3.3.00.1 5.13a3 2.01a11 7.3.x Yes
Oracle Solaris 11 x86_64
Emulex LPe1200x/LPe1205 3.3.00.1 5.13a3 2.01a11 7.4.x Yes
Oracle Solaris 11 x86_64
Emulex LPe1200x/LPe1205 v20120210-2.70i 5.13a3 2.01a11 6.7.x Yes
Oracle Solaris 11 x86_64
Emulex LPe1200x/LPe1205 v20120210-2.70i 5.13a3 2.01a11 7.1.x Yes
Fibre Channel Adapters (SC and SCv Series)
52 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Oracle Solaris 11 x86_64
Emulex LPe1200x/LPe1205 v20120210-2.70i 5.13a3 2.01a11 7.2.x Yes
Oracle Solaris 11 x86_64
Emulex LPe1200x/LPe1205 v20120210-2.70i 5.13a3 2.01a11 7.3.x Yes
Oracle Solaris 11 x86_64
QLogic QxE256x 171019-5.07 3.29 8.05.00 7.3.x Yes
Oracle Solaris 11 x86_64
QLogic QxE256x 171019-5.07 3.29 8.05.00 7.4.x Yes
Oracle Solaris 11 x86_64
QLogic QxE274x 171019-5.07 3.62 8.07.70 7.3.x Yes
Oracle Solaris 11 x86_64
QLogic QxE274x 171019-5.07 3.62 8.07.70 7.4.x Yes
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.27 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.27 3.1(1h) 4.1(1f) 6.7.x Yes Cisco fw kit: 3.1(1h)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.27 3.1(1k) 4.1(1h) 6.7.x Yes Cisco fw kit: 3.1(1k)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.27 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.27 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.34 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.34 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.37 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.37 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d)
Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d)
Red Hat RHEL 6.x Cisco VIC-14xx 1.6.0.50 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a)
Red Hat RHEL 6.x Cisco VIC-14xx 1.6.0.50 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a)
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 10.6.0.20 5.13a11 2.02A1 6.7.x Yes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 10.6.0.20 5.13a11 2.02A1 7.1.x Yes
Fibre Channel Adapters (SC and SCv Series)
53 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 10.6.0.20 7.00a2 2.02A1 7.2.x Yes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.4 5.13a11 2.02A1 7.2.x Yes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.4 7.00a2 2.02A1 6.7.x Yes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.4 7.00a2 2.02A1 7.1.x Yes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.4 7.00a2 2.02A1 7.2.x Yes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.6 11.40a6 2.02a3 7.3.x Yes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.6 5.13a11 2.02A1 7.2.x Yes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.1.6 12.00a4 2.02A4 7.3.x Yes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.1.6 12.00a4 2.02A4 7.4.x Yes
Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 8.3.5.68.5p 5.13a10 2.01A12 6.7.x Yes
Red Hat RHEL 6.x Emulex LPx1500x/LPx1600x 11.0.0.6 11.0.270.14 11.0.270.2002 7.2.x Yes
Red Hat RHEL 6.x Emulex LPx1500x/LPx1600x 11.0.0.6 11.2.216.9 11.2.216.9 7.3.x Yes
Red Hat RHEL 6.x Emulex LPx1500x/LPx1600x 11.0.1.6 11.4.258.16 11.4.258.16 7.3.x Yes
Red Hat RHEL 6.x Emulex LPx1500x/LPx1600x 11.0.1.6 12.0.257.12 12.0.257.12 7.4.x Yes
Red Hat RHEL 6.x Emulex LPx3100x/LPx3200x 11.0.1.6 11.0.270.18 11.0.270.18 7.3.x Yes Dell fw kit: 2.00.03
Red Hat RHEL 6.x Emulex LPx3100x/LPx3200x 11.0.1.6 11.0.270.18 11.0.270.18 7.4.x Yes Dell fw kit: 2.00.03
Red Hat RHEL 6.x QLogic QxE256x 8.05.00.03.06.5-k2 3.27 7.04.00 6.7.x Yes
Red Hat RHEL 6.x QLogic QxE256x 8.07.00.16.06.7-k 3.29 8.01.02 6.7.x Yes
Red Hat RHEL 6.x QLogic QxE256x 8.07.00.16.06.7-k 3.29 8.01.02 7.1.x Yes
Red Hat RHEL 6.x QLogic QxE256x 8.07.00.16.06.7-k 3.29 8.01.02 7.2.x Yes
Red Hat RHEL 6.x QLogic QxE256x 8.07.00.26.06.8-k 3.29 8.01.02 7.2.x Yes
Red Hat RHEL 6.x QLogic QxE256x 8.07.00.26.06.8-k 3.43 8.07.00 7.3.x Yes
Red Hat RHEL 6.x QLogic QxE256x 8.07.00.26.06.8-k 3.43 8.08.01 7.4.x Yes
Red Hat RHEL 6.x QLogic QxE266x 8.07.00.26.06.8-k 3.17 6.04.00 7.2.x Yes
Red Hat RHEL 6.x QLogic QxE266x 8.07.00.26.06.8-k 3.24 7.03.00 7.3.x Yes
Red Hat RHEL 6.x QLogic QxE266x 8.07.00.26.06.8-k 3.24 7.03.00 7.4.x Yes
Red Hat RHEL 6.x QLogic QxE269x 8.07.00.26.06.8-k 3.62 8.08.204 7.3.x Yes Dell fw kit: 14.10.05
Red Hat RHEL 6.x QLogic QxE269x 8.07.00.26.06.8-k 3.62 8.08.204 7.4.x Yes Dell fw kit: 14.10.05
Red Hat RHEL 6.x QLogic QxE274x 8.07.00.26.06.8-k 3.62 8.08.204 7.3.x Yes Dell fw kit: 14.10.05
Fibre Channel Adapters (SC and SCv Series)
54 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Red Hat RHEL 6.x QLogic QxE274x 8.07.00.26.06.8-k 3.62 8.08.204 7.4.x Yes Dell fw kit: 14.10.05
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.25 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.25 3.1(1h) 4.1(1f) 6.7.x Yes Cisco fw kit: 3.1(1h)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.25 3.1(1k) 4.1(1h) 6.7.x Yes Cisco fw kit: 3.1(1k)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.30 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.30 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.34 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.34 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.34 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.34 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.36 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.36 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d)
Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d)
Red Hat RHEL 7.x Cisco VIC-14xx 2.0.0.42 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a)
Red Hat RHEL 7.x Cisco VIC-14xx 2.0.0.42 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a)
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.2.8021.1 5.13a3 2.01A12 6.7.x Yes
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 5.13a11 2.02A1 6.7.x Yes
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 5.13a11 2.02A1 7.1.x Yes
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 5.13a11 2.02A1 7.2.x Yes
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 7.00a2 2.02A1 6.7.x Yes
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 7.00a2 2.02A1 7.1.x Yes
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 7.00a2 2.02A1 7.2.x Yes
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 11.2.0.6 11.40a6 2.02a3 7.3.x Yes
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 11.2.0.6 5.13a11 2.02A1 7.2.x Yes
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 11.4.0.4 12.00a4 2.02A4 7.3.x Yes
Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 12.0.0.5 12.00a4 2.02A4 7.4.x Yes
Fibre Channel Adapters (SC and SCv Series)
55 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Red Hat RHEL 7.x Emulex LPx1500x/LPx1600x 11.2.0.6 11.0.270.14 11.0.270.2002 7.2.x Yes
Red Hat RHEL 7.x Emulex LPx1500x/LPx1600x 11.2.0.6 11.2.216.9 11.2.216.9 7.3.x Yes
Red Hat RHEL 7.x Emulex LPx1500x/LPx1600x 11.4.0.4 11.4.258.16 11.4.258.16 7.3.x Yes
Red Hat RHEL 7.x Emulex LPx1500x/LPx1600x 12.0.0.5 12.0.257.12 12.0.257.12 7.4.x Yes
Red Hat RHEL 7.x Emulex LPx3100x/LPx3200x 11.2.0.6 11.4.165.16 11.4.165.16 7.3.x Yes Dell fw kit: 02.02.01
Red Hat RHEL 7.x Emulex LPx3100x/LPx3200x 11.2.156.20 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.00.04
Red Hat RHEL 7.x Emulex LPx3100x/LPx3200x 11.4.0.4 11.4.258.15 11.4.258.15 7.3.x Yes Dell fw kit: 02.03.02
Red Hat RHEL 7.x Emulex LPx3100x/LPx3200x 11.4.0.4 12.0.257.12 12.0.257.12 7.4.x Yes
Red Hat RHEL 7.x Emulex LPx3500x 12.0.0.5 - 12.0.257.15 7.4.x No Dell fw kit: 3.00.12
Red Hat RHEL 7.x Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.3.x No
Red Hat RHEL 7.x QLogic QxE256x 10.00.00.06.07.6-k 3.43 8.08.01 7.4.x Yes
Red Hat RHEL 7.x QLogic QxE256x 8.07.00.08.07.1-k2 3.27 7.04.00 6.7.x Yes
Red Hat RHEL 7.x QLogic QxE256x 8.07.00.18.07.2-k 3.29 8.01.02 6.7.x Yes
Red Hat RHEL 7.x QLogic QxE256x 8.07.00.18.07.2-k 3.29 8.01.02 7.1.x Yes
Red Hat RHEL 7.x QLogic QxE256x 8.07.00.18.07.2-k 3.29 8.01.02 7.2.x Yes
Red Hat RHEL 7.x QLogic QxE256x 8.07.00.38.07.4-k1 3.29 8.01.02 7.2.x Yes
Red Hat RHEL 7.x QLogic QxE256x 8.07.00.38.07.4-k1 3.43 8.07.00 7.3.x Yes
Red Hat RHEL 7.x QLogic QxE256x 9.00.00.00.07.5-k1 3.43 8.08.01 7.3.x Yes
Red Hat RHEL 7.x QLogic QxE266x 10.00.00.06.07.6-k 3.45 8.07.11 7.4.x Yes
Red Hat RHEL 7.x QLogic QxE266x 8.07.00.08.07.1-k2 3.28 8.00.00 6.7.x Yes
Red Hat RHEL 7.x QLogic QxE266x 8.07.00.18.07.2-k 3.29 8.01.02 6.7.x Yes
Red Hat RHEL 7.x QLogic QxE266x 8.07.00.18.07.2-k 3.29 8.01.02 7.1.x Yes
Red Hat RHEL 7.x QLogic QxE266x 8.07.00.18.07.2-k 3.29 8.01.02 7.2.x Yes
Red Hat RHEL 7.x QLogic QxE266x 8.07.00.38.07.4-k1 3.32 8.03.01 7.2.x Yes
Red Hat RHEL 7.x QLogic QxE266x 8.07.00.38.07.4-k1 3.43 8.07.12 7.3.x Yes
Red Hat RHEL 7.x QLogic QxE266x 9.00.00.00.07.5-k1 3.45 8.07.11 7.3.x Yes
Red Hat RHEL 7.x QLogic QxE269x 8.07.00.38.07.4-k1 3.38 8.03.05 7.2.x Yes Dell fw kit: 08.00.15
Red Hat RHEL 7.x QLogic QxE269x 8.07.00.38.07.4-k1 3.38 8.03.05 7.3.x Yes Dell fw kit: 08.00.15
Red Hat RHEL 7.x QLogic QxE269x 9.00.00.00.07.5-k1 3.62 8.07.80 7.3.x Yes Dell fw kit: 14.04.09
Fibre Channel Adapters (SC and SCv Series)
56 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Red Hat RHEL 7.x QLogic QxE269x 9.00.00.00.07.5-k1 3.62 8.07.80 7.4.x Yes Dell fw kit: 14.04.09
Red Hat RHEL 7.x QLogic QxE274x 8.07.00.38.07.4-k1 3.38 8.03.05 7.2.x Yes Dell fw kit: 08.00.14
Red Hat RHEL 7.x QLogic QxE274x 8.07.00.38.07.4-k1 3.38 8.03.05 7.3.x Yes Dell fw kit: 08.00.14
Red Hat RHEL 7.x QLogic QxE274x 9.00.00.00.07.5-k1 3.62 8.07.80 7.3.x Yes Dell fw kit: 14.04.09
Red Hat RHEL 7.x QLogic QxE274x 9.00.00.00.07.5-k1 3.62 8.07.80 7.4.x Yes Dell fw kit: 14.04.09
Red Hat RHEL 8.x Cisco VIC-13xx 1.6.0.34 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j)
Red Hat RHEL 8.x Cisco VIC-13xx 1.6.0.34 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j)
Red Hat RHEL 8.x Cisco VIC-13xx 1.6.0.34 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d)
Red Hat RHEL 8.x Cisco VIC-13xx 1.6.0.34 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d)
Red Hat RHEL 8.x Cisco VIC-14xx 1.6.0.34 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a)
Red Hat RHEL 8.x Cisco VIC-14xx 1.6.0.34 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a)
Red Hat RHEL 8.x Emulex LPe1200x/LPe1205 12.0.0.6 12.00a4 2.02A4 7.3.x Yes
Red Hat RHEL 8.x Emulex LPe1200x/LPe1205 12.0.0.6 12.00a4 2.02A4 7.4.x Yes
Red Hat RHEL 8.x Emulex LPx1500x/LPx1600x 12.0.0.6 11.4.258.16 11.4.258.16 7.3.x Yes
Red Hat RHEL 8.x Emulex LPx1500x/LPx1600x 12.0.0.6 12.0.257.12 12.0.257.12 7.4.x Yes
Red Hat RHEL 8.x Emulex LPx3100x/LPx3200x 12.0.0.6 11.0.270.18 11.0.270.18 7.3.x Yes Dell fw kit: 2.00.03
Red Hat RHEL 8.x Emulex LPx3100x/LPx3200x 12.0.0.6 11.0.270.18 11.0.270.18 7.4.x Yes Dell fw kit: 2.00.03
Red Hat RHEL 8.x QLogic QxE256x 10.00.00.07.08.0-k1
3.43 8.07.00 7.3.x Yes
Red Hat RHEL 8.x QLogic QxE256x 10.00.00.07.08.0-k1
3.43 8.08.01 7.4.x Yes
Red Hat RHEL 8.x QLogic QxE266x 10.00.00.07.08.0-k1
3.24 7.03.00 7.3.x Yes
Red Hat RHEL 8.x QLogic QxE266x 10.00.00.07.08.0-k1
3.24 7.03.00 7.4.x Yes
Red Hat RHEL 8.x QLogic QxE269x 10.00.00.07.08.0-k1
3.62 8.08.204 7.3.x Yes Dell fw kit: 14.10.05
Red Hat RHEL 8.x QLogic QxE269x 10.00.00.07.08.0-k1
3.62 8.08.204 7.4.x Yes Dell fw kit: 14.10.05
Red Hat RHEL 8.x QLogic QxE274x 10.00.00.07.08.0-k1
3.62 8.08.204 7.3.x Yes Dell fw kit: 14.10.05
Fibre Channel Adapters (SC and SCv Series)
57 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Red Hat RHEL 8.x QLogic QxE274x 10.00.00.07.08.0-k1
3.62 8.08.204 7.4.x Yes Dell fw kit: 14.10.05
Ubuntu 18.4 Emulex LPx1500x/LPx1600x 12.0.0.0 12.0.257.12 12.0.257.12 7.3.x Yes
Ubuntu 18.4 Emulex LPx1500x/LPx1600x 12.0.0.0 12.0.257.12 12.0.257.12 7.4.x Yes
Ubuntu 18.4 Emulex LPx3100x/LPx3200x 12.0.0.0 12.0.257.12 12.0.257.12 7.3.x Yes
Ubuntu 18.4 Emulex LPx3100x/LPx3200x 12.0.0.0 12.0.257.12 12.0.257.12 7.4.x Yes
Ubuntu 18.4 QLogic QxE266x 10.00.00.02-k 3.45 8.07.11 7.3.x Yes
Ubuntu 18.4 QLogic QxE266x 10.00.00.02-k 3.45 8.07.11 7.4.x Yes
Ubuntu 18.4 QLogic QxE274x 10.00.00.02-k 3.62 8.07.80 7.3.x Yes Dell fw kit: 14.04.09
Ubuntu 18.4 QLogic QxE274x 10.00.00.02-k 3.62 8.07.80 7.4.x Yes Dell fw kit: 14.04.09
VMWare ESXi 5.5 Cisco VIC-13xx 1.6.0.16 3.0(2c) 3.0(2c) 6.7.x Yes
VMWare ESXi 5.5 Cisco VIC-13xx 1.6.0.28 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d
VMWare ESXi 5.5 Cisco VIC-13xx 1.6.0.28 3.1(1h) 4.1(1f) 6.7.x Yes Cisco fw kit: 3.1(1h)
VMWare ESXi 5.5 Cisco VIC-13xx 1.6.0.28 3.1(1k) 4.1(1h) 6.7.x Yes Cisco fw kit: 3.1(1k)
VMWare ESXi 5.5 Emulex LPx1500x/LPx1600x 10.6.126.0 10.6.133.18 10.6.133.18 6.7.x Yes Dell fw kit: 01.06.01
VMWare ESXi 5.5 Emulex LPx1500x/LPx1600x 10.6.126.0 10.6.133.18 10.6.133.18 7.1.x Yes Dell fw kit: 01.06.01
VMWare ESXi 5.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 6.7.x Yes Dell fw kit: 02.00.04
VMWare ESXi 5.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.04
VMWare ESXi 5.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.2.x Yes Dell fw kit: 02.00.04
VMWare ESXi 5.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01
VMWare ESXi 5.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01
VMWare ESXi 5.5 QLogic QxE257x 1.1.55.0 3.24 7.04.00 6.7.x Yes Dell fw kit: 3.22.00
VMWare ESXi 5.5 QLogic QxE257x 1.1.55.0 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.22.07
VMWare ESXi 5.5 QLogic QxE257x 1.1.55.0 3.31 8.01.02 7.1.x Yes Dell fw kit: 03.22.08
VMWare ESXi 5.5 QLogic QxE257x 1.1.55.0 3.31 8.01.02 7.2.x Yes Dell fw kit: 03.22.08
VMWare ESXi 5.5 QLogic QxE257x 1.1.70.0 3.31 8.01.02 6.7.x Yes Dell fw kit: 03.22.08
VMWare ESXi 5.5 QLogic QxE257x 1.1.70.0 3.31 8.01.02 7.2.x Yes Dell fw kit: 03.22.08
VMWare ESXi 5.5 QLogic QxE257x 1.1.70.0 3.4 8.01.02 7.2.x Yes Dell fw kit: 09.00.03
VMWare ESXi 5.5 QLogic QxE257x 1.1.70.0 3.4 8.01.02 7.3.x Yes Dell fw kit: 09.00.03
VMWare ESXi 5.5 QLogic QxE266x 1.1.55.0 3.29 7.04.00 6.7.x Yes Dell fw kit: 3.11.18
Fibre Channel Adapters (SC and SCv Series)
58 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
VMWare ESXi 5.5 QLogic QxE266x 1.1.70.0 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.11.25
VMWare ESXi 5.5 QLogic QxE266x 1.1.70.0 3.43 8.05.01 7.2.x Yes Dell fw kit: 09.00.06
VMWare ESXi 5.5 QLogic QxE266x 1.1.70.0 3.43 8.05.01 7.3.x Yes Dell fw kit: 09.00.06
VMWare ESXi 5.5 QLogic QxE266x 1.1.70.0 3.44 8.03.01 7.1.x Yes Dell fw kit: 08.00.15
VMWare ESXi 5.5 QLogic QxE266x 1.1.70.0 3.44 8.03.01 7.2.x Yes Dell fw kit: 08.00.15
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.28 3.1(1h) 4.1(1f) 6.7.x Yes Cisco fw kit: 3.1(1h)
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.28 3.1(1k) 4.1(1h) 6.7.x Yes Cisco fw kit: 3.1(1k)
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.33 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.33 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.33 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.34 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a)
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.34 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c)
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.34 3.1(3d) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3d)
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g)
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g)
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e)
VMWare ESXi 6.0 Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e)
VMWare ESXi 6.0 Emulex LPe1200x/LPe1205 10.5.70.0 6.03X1 2.01A12 6.7.x Yes Dell fw kit: 01.06.01
VMWare ESXi 6.0 Emulex LPe1200x/LPe1205 10.6.126.0 6.03X1 2.01A12 7.1.x Yes Dell fw kit: 01.06.01
VMWare ESXi 6.0 Emulex LPe1200x/LPe1205 11.1.145.18 7.00x1 2.02A1 6.7.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.0 Emulex LPe1200x/LPe1205 11.1.145.18 7.00x1 2.02A1 7.1.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.0 Emulex LPe1200x/LPe1205 11.1.145.18 7.00x1 2.02A1 7.2.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.0 Emulex LPe1200x/LPe1205 11.2.156.20 6.03X1 2.02a3 7.2.x Yes Dell fw kit: 02.01.01*
VMWare ESXi 6.0 Emulex LPe1200x/LPe1205 11.4.142.11 6.03X1 2.02a3 7.3.x Yes Dell fw kit: 02.01.01*
VMWare ESXi 6.0 Emulex LPx1500x/LPx1600x 10.6.126.0 10.6.133.18 10.6.133.18 6.7.x Yes Dell fw kit: 01.06.01
VMWare ESXi 6.0 Emulex LPx1500x/LPx1600x 10.6.126.0 10.6.133.18 10.6.133.18 7.1.x Yes Dell fw kit: 01.06.01
VMWare ESXi 6.0 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.0 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.2.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.0 Emulex LPx1500x/LPx1600x 11.2.156.20 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01
Fibre Channel Adapters (SC and SCv Series)
59 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
VMWare ESXi 6.0 Emulex LPx1500x/LPx1600x 11.4.142.11 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.0 Emulex LPx3100x/LPx3200x 11.2.156.20 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.0 Emulex LPx3100x/LPx3200x 11.4.142.11 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.0 QLogic QxE257x 2.1.20.0 3.24 7.04.00 6.7.x Yes Dell fw kit: 3.22.00
VMWare ESXi 6.0 QLogic QxE257x 2.1.24.0 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.22.07
VMWare ESXi 6.0 QLogic QxE257x 2.1.24.0 3.31 8.01.02 7.1.x Yes Dell fw kit: 03.22.08
VMWare ESXi 6.0 QLogic QxE257x 2.1.24.0 3.31 8.01.02 7.2.x Yes Dell fw kit: 03.22.08
VMWare ESXi 6.0 QLogic QxE257x 2.1.43.0 3.31 8.01.02 6.7.x Yes Dell fw kit: 03.22.08
VMWare ESXi 6.0 QLogic QxE257x 2.1.43.0 3.31 8.01.02 7.2.x Yes Dell fw kit: 03.22.08
VMWare ESXi 6.0 QLogic QxE257x 2.1.50.0 3.4 8.02.00 7.2.x Yes Dell fw kit: 09.00.03
VMWare ESXi 6.0 QLogic QxE257x 2.1.57.0 3.4 8.02.00 7.3.x Yes Dell fw kit: 09.00.03
VMWare ESXi 6.0 QLogic QxE266x 2.1.20.0 3.29 7.04.00 6.7.x Yes Dell fw kit: 3.11.18
VMWare ESXi 6.0 QLogic QxE266x 2.1.24.0 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.11.25
VMWare ESXi 6.0 QLogic QxE266x 2.1.43.0 3.44 8.03.01 7.1.x Yes Dell fw kit: 08.00.15
VMWare ESXi 6.0 QLogic QxE266x 2.1.43.0 3.44 8.03.01 7.2.x Yes Dell fw kit: 08.00.15
VMWare ESXi 6.0 QLogic QxE266x 2.1.50.0 3.43 8.05.01 7.2.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.0 QLogic QxE266x 2.1.57.0 3.43 8.05.01 7.3.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.0 QLogic QxE269x 2.1.50.0 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.0 QLogic QxE269x 2.1.57.0 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.0 QLogic QxE274x 2.1.50.0 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.0 QLogic QxE274x 2.1.57.0 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.28 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.28 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.34 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.34 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.34 3.1(3d) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3d)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e)
Fibre Channel Adapters (SC and SCv Series)
60 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.37 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.37 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d)
VMWare ESXi 6.5 Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d)
VMWare ESXi 6.5 Cisco VIC-14xx 1.6.0.50 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a)
VMWare ESXi 6.5 Cisco VIC-14xx 1.6.0.50 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a)
VMWare ESXi 6.5 Emulex LPe1200x/LPe1205 12.0.257.5-1oem 12.00a4 2.02A4 7.3.x Yes
VMWare ESXi 6.5 Emulex LPe1200x/LPe1205 12.0.257.5-1oem 12.00a4 2.02A4 7.4.x Yes
VMWare ESXi 6.5 Emulex LPx1500x/LPx1600x 11.1.0.6 11.0.270.9 11.0.270.2002 6.7.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.5 Emulex LPx1500x/LPx1600x 11.1.0.6 11.0.270.9 11.0.270.2002 7.2.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.2.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.5 Emulex LPx1500x/LPx1600x 11.2.156.20 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.5 Emulex LPx1500x/LPx1600x 11.4.142.11 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.5 Emulex LPx1500x/LPx1600x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.3.x Yes
VMWare ESXi 6.5 Emulex LPx1500x/LPx1600x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.4.x Yes
VMWare ESXi 6.5 Emulex LPx3100x/LPx3200x 11.2.156.20 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.5 Emulex LPx3100x/LPx3200x 11.4.142.11 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.5 Emulex LPx3100x/LPx3200x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.3.x Yes
VMWare ESXi 6.5 Emulex LPx3100x/LPx3200x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.4.x Yes
VMWare ESXi 6.5 Emulex LPx3500x 12.0.257.5 12.0.257.12 12.0.257.15 7.3.x Yes
VMWare ESXi 6.5 Emulex LPx3500x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.4.x Yes
VMWare ESXi 6.5 QLogic QxE256x 2.1.74.0 3.27 7.4.0 7.3.x Yes
VMWare ESXi 6.5 QLogic QxE256x 2.1.74.0 3.27 7.4.0 7.4.x Yes
VMWare ESXi 6.5 QLogic QxE266x 2.1.43.0 3.44 8.03.01 6.7.x Yes Dell fw kit: 08.00.15
VMWare ESXi 6.5 QLogic QxE266x 2.1.43.0 3.44 8.03.01 7.1.x Yes Dell fw kit: 08.00.15
VMWare ESXi 6.5 QLogic QxE266x 2.1.43.0 3.44 8.03.01 7.2.x Yes Dell fw kit: 08.00.15
VMWare ESXi 6.5 QLogic QxE266x 2.1.50.0 3.43 8.05.01 7.2.x Yes Dell fw kit: 09.00.06
Fibre Channel Adapters (SC and SCv Series)
61 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
VMWare ESXi 6.5 QLogic QxE266x 2.1.57.0 3.43 8.05.01 7.3.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.5 QLogic QxE266x 2.1.74.0 3.45 8.7.11 7.3.x Yes
VMWare ESXi 6.5 QLogic QxE266x 2.1.74.0 3.45 8.7.11 7.4.x Yes
VMWare ESXi 6.5 QLogic QxE269x 2.1.57.0 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.5 QLogic QxE269x 2.1.74.0 3.62 8.07.80 7.3.x Yes
VMWare ESXi 6.5 QLogic QxE269x 2.1.74.0 3.62 8.07.80 7.4.x Yes
VMWare ESXi 6.5 QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.5 QLogic QxE274x 2.1.57.0 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.5 QLogic QxE274x 2.1.74.0 3.62 8.07.80 7.3.x Yes
VMWare ESXi 6.5 QLogic QxE274x 2.1.74.0 3.62 8.07.80 7.4.x Yes
VMWare ESXi 6.5 QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.7 Cisco VIC-13xx 4.0.0.14 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j)
VMWare ESXi 6.7 Cisco VIC-13xx 4.0.0.14 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j)
VMWare ESXi 6.7 Cisco VIC-13xx 4.0.0.24 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d)
VMWare ESXi 6.7 Cisco VIC-13xx 4.0.0.24 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d)
VMWare ESXi 6.7 Cisco VIC-14xx 4.0.0.35 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a)
VMWare ESXi 6.7 Cisco VIC-14xx 4.0.0.35 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a)
VMWare ESXi 6.7 Emulex LPe1200x/LPe1205 12.0.257.5-1oem 12.00a4 2.02A4 7.3.x Yes
VMWare ESXi 6.7 Emulex LPe1200x/LPe1205 12.0.257.5-1oem 12.00a4 2.02A4 7.4.x Yes
VMWare ESXi 6.7 Emulex LPx1500x/LPx1600x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.3.x Yes
VMWare ESXi 6.7 Emulex LPx1500x/LPx1600x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.4.x Yes
VMWare ESXi 6.7 Emulex LPx3100x/LPx3200x 11.4.142.11 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.7 Emulex LPx3100x/LPx3200x 11.4.142.11 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.7 Emulex LPx3100x/LPx3200x 12.0.193.14 12.0.257.12 12.0.257.12 7.3.x Yes Dell fw kit: 3.00.12
VMWare ESXi 6.7 Emulex LPx3100x/LPx3200x 12.0.193.14 12.0.257.12 12.0.257.12 7.4.x Yes Dell fw kit: 3.00.12
VMWare ESXi 6.7 Emulex LPx3500x 12.0.257.5 12.0.257.12 12.0.257.15 7.3.x Yes
VMWare ESXi 6.7 Emulex LPx3500x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.4.x Yes
VMWare ESXi 6.7 QLogic QxE256x 3.1.9.0 3.27 7.4.0 7.3.x Yes
VMWare ESXi 6.7 QLogic QxE256x 3.1.9.0 3.27 7.4.0 7.4.x Yes
Fibre Channel Adapters (SC and SCv Series)
62 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FC Host Adapter Driver BootCode Firmware SC Version
BfS Notes
VMWare ESXi 6.7 QLogic QxE266x 3.1.9.0 3.45 8.7.11 7.3.x Yes
VMWare ESXi 6.7 QLogic QxE266x 3.1.9.0 3.45 8.7.11 7.4.x Yes
VMWare ESXi 6.7 QLogic QxE269x 3.1.8.0 3.62 8.07.80 7.3.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.7 QLogic QxE269x 3.1.8.0 3.62 8.07.80 7.4.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.7 QLogic QxE274x 2.1.57.0 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.7 QLogic QxE274x 2.1.57.0 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.7 QLogic QxE274x 3.1.8.0 3.62 8.07.80 7.3.x Yes Dell fw kit: 09.00.06
VMWare ESXi 6.7 QLogic QxE274x 3.1.8.0 3.62 8.07.80 7.4.x Yes Dell fw kit: 09.00.06
iSCSI converged network and host bus adapters (SC and SCv Series)
63 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4.3 iSCSI Adapters
4.3.1 iSCSI converged network and host bus adapters (SC and SCv Series)
Operating System iSCSI Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Citrix XenServer 7.2 Broadcom 578xx 1.714.1 - 14.02.12 7.3.x No
Microsoft 2008 Windows Server R2 SP1
Emulex OCx1410x 10.6.116.0 10.6.133.18 1.06.01 6.7.x Yes
Microsoft 2008 Windows Server R2 SP1
Emulex OCx1410x 10.6.126.0 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01
Microsoft 2008 Windows Server R2 SP1
Emulex OCx1410x 11.0.271.0 - 11.0.270.2007 7.2.x No Dell fw kit: 02.00.04
Microsoft 2008 Windows Server R2 SP1
Emulex OCx1410x 11.2.1099.0 - 11.2.1197.13 7.2.x No Dell fw kit: 02.01.01
Microsoft 2008 Windows Server R2 SP1
Emulex OCx1410x 11.2.1099.0 - 11.2.1197.13 7.3.x No Dell fw kit: 02.01.01
Microsoft 2008 Windows Server R2 SP1
QLogic QLE406x 2.1.4.26 - 3.0.1.75 6.7.x Yes
Microsoft 2008 Windows Server R2 SP1
QLogic QLE406x 2.1.4.26 - 3.0.1.75 7.1.x Yes
Microsoft 2008 Windows Server R2 SP1
QLogic QLE406x 2.1.4.26 - 3.0.1.75 7.2.x Yes
iSCSI converged network and host bus adapters (SC and SCv Series)
64 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System iSCSI Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE826x 2.1.6.10 2.0.1.35 2.10.29 6.7.x Yes
Microsoft 2008 Windows Server R2 SP1
Broadcom 578xx 7.12.32.0 7.12.1 08.07.25 7.2.x Yes
Microsoft 2008 Windows Server R2 SP1
Broadcom 578xx 7.14.1.1 7.15.0 14.02.12 7.3.x Yes Dell fw kit: 14.02.01
Microsoft 2012 Windows Server
Emulex OCx1410x 10.6.116.0 10.6.133.18 1.06.01 6.7.x Yes
Microsoft 2012 Windows Server
Emulex OCx1410x 10.6.116.0 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01
Microsoft 2012 Windows Server
QLogic QxE826x 2.1.6.10 2.0.1.35 2.10.29 6.7.x Yes
Microsoft 2012 Windows Server
Broadcom 578xx 7.0.13.51 7.15.0 14.02.01 7.3.x Yes
Microsoft 2012 Windows Server
Broadcom 578xx 7.12.32.0 7.12.1 08.07.25 7.2.x Yes
Microsoft 2012 Windows Server R2
Emulex OCx1410x 10.6.114.0 10.6.133.18 10.6.133.18 6.7.x Yes
Microsoft 2012 Windows Server R2
Emulex OCx1410x 10.6.116.0 10.6.133.18 1.06.01 6.7.x Yes
Microsoft 2012 Windows Server R2
Emulex OCx1410x 10.6.116.0 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.0.271.0 11.0.243.16 11.0.243.16 7.1.x Yes
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.0.271.0 11.0.270.15 11.0.270.15 7.1.x Yes Dell fw kit: 02.00.01
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.0.271.0 11.0.270.2007 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.0.271.0 11.0.270.2007 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04
iSCSI converged network and host bus adapters (SC and SCv Series)
65 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System iSCSI Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.2.1153.23 11.2.197.13 11.2.197.13 7.2.x Yes Dell fw kit: 02.01.01
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.2.1153.23 11.2.197.13 11.2.197.13 7.3.x Yes Dell fw kit: 02.01.01
Microsoft 2012 Windows Server R2
QLogic QLE406x 2.1.4.27 - 3.0.1.75 6.7.x No
Microsoft 2012 Windows Server R2
QLogic QLE406x 2.1.4.27 - 3.0.1.75 7.1.x No
Microsoft 2012 Windows Server R2
QLogic QLE406x 2.1.4.27 - 3.0.1.75 7.2.x No
Microsoft 2012 Windows Server R2
QLogic QxE826x 2.1.6.10 2.0.1.35 2.10.29 6.7.x Yes
Microsoft 2012 Windows Server R2
QLogic QxE826x 2.1.6.10 2.21 4.18.04 6.7.x Yes Dell fw kit: 2.10.29
Microsoft 2012 Windows Server R2
QLogic QxE826x 2.1.6.10 2.22 4.18.04 7.1.x Yes Dell fw kit: 02.10.38
Microsoft 2012 Windows Server R2
QLogic QxE826x 2.1.6.10 2.22 4.18.04 7.2.x Yes Dell fw kit: 02.10.38
Microsoft 2012 Windows Server R2
QLogic QxE826x 2.1.6.10 2.22 4.20.21 7.2.x Yes Dell fw kit: 09.00.03
Microsoft 2012 Windows Server R2
QLogic QxE826x 2.1.6.10 2.22 4.20.21 7.3.x Yes Dell fw kit: 09.00.03
Microsoft 2012 Windows Server R2
Broadcom 578xx 7.12.32.0 7.12.1 08.07.25 7.2.x Yes
Microsoft 2012 Windows Server R2
Broadcom 578xx 7.4.4.0 7.15.0 14.02.12 7.3.x Yes
Microsoft 2012 Windows Server R2
QLogic QL41xxx 8.33.5.2 - 14.07.07 7.3.x No Not recommended with XL710, i350, or x540 in Storage Center
Microsoft 2012 Windows Server R2
QLogic QL41xxx 8.33.5.2 - 14.07.07 7.4.x No Not recommended with XL710, i350, or x540 in Storage Center
Microsoft 2016 Windows Server
Emulex OCx1410x 11.0.271.0 - 11.0.270.2007 7.2.x No Dell fw kit: 02.00.04
Microsoft 2016 Windows Server
Emulex OCx1410x 11.2.1153.23 - 11.2.1197.13 7.2.x No Dell fw kit: 02.01.01
iSCSI converged network and host bus adapters (SC and SCv Series)
66 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System iSCSI Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Microsoft 2016 Windows Server
Emulex OCx1410x 11.2.1153.23 - 11.2.1197.13 7.3.x No Dell fw kit: 02.01.01
Microsoft 2016 Windows Server
Emulex OCx1410x 11.2.1153.23 - 11.2.1197.13 7.4.x No Dell fw kit: 02.01.01
Microsoft 2016 Windows Server
Broadcom 578xx 7.14.4.0 - 14.02.12 7.3.x No
Microsoft 2016 Windows Server
QLogic QL41xxx 8.24.5 - 14.07.04 7.3.x No Not recommended with XL710, i350, or x540 in Storage Center
Microsoft 2016 Windows Server
QLogic QL41xxx 8.33.5.2 - 14.07.07 7.3.x No Not recommended with XL710, i350, or x540 in Storage Center
Microsoft 2016 Windows Server
QLogic QL41xxx 8.33.5.2 - 14.07.07 7.4.x No Not recommended with XL710, i350, or x540 in Storage Center
Microsoft 2019 Windows Server
Emulex OCx1410x 11.2.1153.23 - 11.2.1197.13 7.3.x No Dell fw kit: 02.01.01
Microsoft 2019 Windows Server
Emulex OCx1410x 11.2.1153.23 - 11.2.1197.13 7.4.x No Dell fw kit: 02.01.01
Microsoft 2019 Windows Server
QLogic QL41xxx 8.33.5.2 - 14.07.07 7.3.x No Not recommended with XL710, i350, or x540 in Storage Center
Microsoft 2019 Windows Server
QLogic QL41xxx 8.33.5.2 - 14.07.07 7.4.x No Not recommended with XL710, i350, or x540 in Storage Center
Novell SLES 11 SP3 Emulex OCx1410x 10.4.114.0 10.2.506.19 1.05.01 6.7.x Yes
Novell SLES 11 SP3 Emulex OCx1410x 10.6.0.2 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01
Novell SLES 11 SP3 QLogic QLE406x 5.03.00.06.11.3-k0
- 3.0.1.75 6.7.x No
Novell SLES 11 SP3 QLogic QxE826x 5.03.00.00.11.4-ko
2.0.1.35 2.10.29 6.7.x Yes
Novell SLES 11 SP3 Broadcom 578xx 2.7.6.2 7.12.1 08.07.25 7.2.x Yes
Novell SLES 11 SP4 QLogic QLE406x 5.03.00.00.11.4-k0
- 3.0.1.75 6.7.x No
Novell SLES 11 SP4 QLogic QLE406x 5.03.00.00.11.4-k0
- 3.0.1.75 7.1.x No
Novell SLES 11 SP4 QLogic QLE406x 5.03.00.00.11.4-k0
- 3.0.1.75 7.2.x No
Novell SLES 12 Emulex OCx1410x 10.6.0.2 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01
iSCSI converged network and host bus adapters (SC and SCv Series)
67 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System iSCSI Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Novell SLES 12 Emulex OCx1410x 10.6.0.2 10.6.133.18 1.06.01 7.2.x Yes Dell fw kit: 01.06.01
Novell SLES 12 QLogic QLE406x 5.04.00.00.12.0-k3
- 3.0.1.75 6.7.x No
Novell SLES 12 Broadcom 578xx 2.7.10.1 7.14.10 14.02.12 7.3.x Yes
Novell SLES 12 SP1 Emulex OCx1410x 10.6.0.0 - 11.0.243.16 7.2.x No
Novell SLES 12 SP1 Emulex OCx1410x 11.0.0.0 - 11.0.270.2007 7.2.x No
Novell SLES 12 SP1 Emulex OCx1410x 11.0.230.0 - 11.0.243.16 7.1.x No
Novell SLES 12 SP1 Emulex OCx1410x 11.2.1.0 - 11.2.1197.13 7.3.x No Dell fw kit: 02.01.01
Novell SLES 12 SP1 Emulex OCx1410x 11.2.1.0 - 11.2.1197.13 7.4.x No Dell fw kit: 02.01.01
Novell SLES 12 SP1 QLogic QLE406x 5.04.00.00.12.1-k0
- 3.0.1.75 6.7.x No
Red Hat RHEL 6.x Emulex OCx1410x 10.4.272.0r 10.2.506.19 1.05.01 6.7.x Yes
Red Hat RHEL 6.x Emulex OCx1410x 10.4.272.0r 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01
Red Hat RHEL 6.x QLogic QLE406x 5.02.00.00.06.03-k4
- 3.0.1.75 6.7.x No
Red Hat RHEL 6.x QLogic QLE406x 5.03.00.00.06.07-k0
- 3.0.1.75 6.7.x No
Red Hat RHEL 6.x QLogic QLE406x 5.03.00.00.06.07-k0
- 3.0.1.75 7.1.x No
Red Hat RHEL 6.x QLogic QLE406x 5.03.00.00.06.07-k0
- 3.0.1.75 7.2.x No
Red Hat RHEL 6.x QLogic QxE826x 5.4.1.9.0.0-ko 2.0.1.35 2.10.29 6.7.x Yes
Red Hat RHEL 6.x Broadcom 578xx 1.712.30.0 7.15.0 14.02.12 7.3.x Yes
Red Hat RHEL 6.x Broadcom 578xx 1.712.30.6 7.14.10 14.02.12 7.3.x Yes
Red Hat RHEL 6.x Broadcom 578xx 2.7.10.1 7.12.1 08.07.25 7.2.x Yes
Red Hat RHEL 7.x Emulex OCx1410x 10.6.0.0r - 11.0.270.2007 6.7.x No Dell fw kit: 02.00.04
Red Hat RHEL 7.x Emulex OCx1410x 10.6.0.0r - 11.0.270.2007 7.2.x No Dell fw kit: 02.00.04
Red Hat RHEL 7.x Emulex OCx1410x 11.2.1.0 - 11.0.270.2007 7.3.x No Dell fw kit: 02.00.04
Red Hat RHEL 7.x Emulex OCx1410x 11.4.0.0r - 11.0.270.2007 7.2.x No Dell fw kit: 02.00.04
Red Hat RHEL 7.x Emulex OCx1410x 11.4.0.1 - 11.2.1197.13 7.3.x No Dell fw kit: 02.01.01
Red Hat RHEL 7.x Emulex OCx1410x 11.4.0.1 - 11.2.1197.13 7.4.x No Dell fw kit: 02.01.01
iSCSI converged network and host bus adapters (SC and SCv Series)
68 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System iSCSI Host Adapter Driver BootCode Firmware SC Version
BfS Notes
Red Hat RHEL 7.x QLogic QLE406x 5.02.04.06.05.10-d0
- 3.0.1.75 6.7.x No
Red Hat RHEL 7.x QLogic QLE406x 5.04.00.00.07.02-k0
- 3.0.1.75 6.7.x No
Red Hat RHEL 7.x Broadcom 578xx 2.7.10.1 7.12.1 08.07.25 7.2.x Yes
Red Hat RHEL 7.x QLogic QL41xxx 8.33.0.20 - 14.07.07 7.3.x No
VMWare ESXi 5.5 Emulex OCx1410x 10.2.309.5 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01
VMWare ESXi 5.5 Emulex OCx1410x 10.6.150.3 10.6.133.18 10.6.133.18 6.7.x Yes Dell fw kit: 01.06.01
VMWare ESXi 5.5 Emulex OCx1410x 10.6.163.0 10.2.506.19 1.05.01 6.7.x Yes
VMWare ESXi 5.5 Emulex OCx1410x 11.0.231.0 11.0.270.15 11.0.231.0 7.1.x Yes Dell fw kit: 02.00.03
VMWare ESXi 5.5 Emulex OCx1410x 11.1.145.8 11.0.270.2007 11.0.270.2007 6.7.x Yes Dell fw kit: 02.00.04
VMWare ESXi 5.5 Emulex OCx1410x 11.1.145.8 11.0.270.2007 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04
VMWare ESXi 5.5 Emulex OCx1410x 11.1.145.8 11.0.270.2007 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04
VMWare ESXi 5.5 Emulex OCx1410x 11.1.145.8 11.2.1197.13 11.2.1197.13 7.2.x Yes Dell fw kit: 02.01.01
VMWare ESXi 5.5 Emulex OCx1410x 11.1.145.8 11.2.1197.13 11.2.1197.13 7.3.x Yes Dell fw kit: 02.01.01
VMWare ESXi 5.5 QLogic QxE826x 644.55.34.0 2.21 4.18.04 6.7.x Yes Dell fw kit: 2.10.29
VMWare ESXi 5.5 QLogic QxE826x 644.55.34.0-1 2.0.1.35 2.10.29 6.7.x Yes
VMWare ESXi 5.5 QLogic QxE826x 644.55.36.0 2.22 4.18.04 7.1.x Yes Dell fw kit: 02.10.37
VMWare ESXi 5.5 QLogic QxE826x 644.55.37.0 2.22 4.18.04 7.1.x Yes Dell fw kit: 02.10.38
VMWare ESXi 5.5 QLogic QxE826x 644.55.37.0 2.22 4.18.04 7.2.x Yes Dell fw kit: 02.10.38
VMWare ESXi 5.5 QLogic QxE826x 644.55.37.0 2.22 4.20.21 7.2.x Yes Dell fw kit: 09.00.03
VMWare ESXi 5.5 QLogic QxE826x 644.55.37.0 2.22 4.20.21 7.3.x Yes Dell fw kit: 09.00.03
VMWare ESXi 5.5 Broadcom 578xx 1.712.70.v55.5 7.12.1 08.07.25 7.2.x Yes
VMWare ESXi 5.5 Broadcom 578xx 2.712 7.14.10 14.02.12 7.3.x Yes
VMWare ESXi 5.5 Broadcom 578xx 2.712.30.v55.1 7.12.4 7.12.17 6.7.x Yes
VMWare ESXi 5.5 Broadcom 578xx 2.712.70.v55.3 7.12.1 08.07.25 6.7.x Yes
VMWare ESXi 5.5 Broadcom 578xx 2.712.70.v55.3 7.12.1 08.07.25 7.1.x Yes
VMWare ESXi 5.5 Broadcom 578xx 2.712.70.v55.3 7.12.1 08.07.25 7.2.x Yes
VMWare ESXi 5.5 Broadcom 578xx 2.712.70.v55.3 7.12.5 7.12.19 7.1.x Yes
VMWare ESXi 5.5 Broadcom 578xx 2.713.10.v55.3 7.15.0 10.01.00 7.2.x Yes Dell fw kit: 10.01.00
VMWare ESXi 5.5 Broadcom 578xx 2.713.10.v55.3 7.15.0 10.01.00 7.3.x Yes Dell fw kit: 10.01.00
iSCSI converged network and host bus adapters (SC and SCv Series)
69 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System iSCSI Host Adapter Driver BootCode Firmware SC Version
BfS Notes
VMWare ESXi 6.0 Emulex OCx1410x 10.2.309.6 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01
VMWare ESXi 6.0 Emulex OCx1410x 11.0.231.0 11.0.270.2002 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.03
VMWare ESXi 6.0 Emulex OCx1410x 11.1.145.8 11.0.270.2007 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.0 Emulex OCx1410x 11.1.145.8 11.0.270.2007 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.0 Emulex OCx1410x 11.2.1147.5 11.2.1197.13 11.2.1197.13 7.2.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.0 Emulex OCx1410x 11.4.142.11 11.2.1197.13 11.2.1197.13 7.3.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.0 QLogic QxE826x 644.55.34.0 2.21 4.18.04 6.7.x Yes Dell fw kit: 2.10.29
VMWare ESXi 6.0 QLogic QxE826x 644.55.36.0 2.22 4.18.04 7.1.x Yes Dell fw kit: 02.10.38
VMWare ESXi 6.0 QLogic QxE826x 644.55.36.0 2.22 4.18.04 7.2.x Yes Dell fw kit: 02.10.38
VMWare ESXi 6.0 QLogic QxE826x 644.55.37.0 2.22 4.20.21 7.2.x Yes Dell fw kit: 09.00.03
VMWare ESXi 6.0 QLogic QxE826x 644.6.06.0 2.22 4.20.21 7.3.x Yes Dell fw kit: 09.00.03
VMWare ESXi 6.0 Broadcom 578xx 1.712.70.v55.5 7.12.1 08.07.25 7.2.x Yes
VMWare ESXi 6.0 Broadcom 578xx 2.712 7.13.54 08.07.25 7.3.x Yes Dell fw kit: 14.02.12
VMWare ESXi 6.5 QLogic QxE826x 644.6.06.0 - 4.18.04 7.2.x No Dell fw kit: 02.10.38
VMWare ESXi 6.5 QLogic QxE826x 644.6.06.0 - 4.20.21 7.2.x No Dell fw kit: 09.00.03
VMWare ESXi 6.5 QLogic QxE826x 644.6.06.0 - 4.20.21 7.3.x No Dell fw kit: 09.00.03
VMWare ESXi 6.5 Broadcom 578xx 2.713 7.14.10 14.02.12 7.3.x Yes
VMWare ESXi 6.5 Broadcom 578xx 2.713.10.v60.3 - N/A 7.2.x No Dell fw kit: 08.07.25
VMWare ESXi 6.5 Broadcom 578xx 2.713.30.v60.5 - 10.01.00 7.2.x No Dell fw kit: 10.01.00
VMWare ESXi 6.5 QLogic QL41xxx 1.0.22.0-1 - 14.03.03 7.2.x No Not recommended with XL710, i350, or x540 in Storage Center
VMWare ESXi 6.5 QLogic QL41xxx 1.0.22.0-1 - 14.03.03 7.3.x No Not recommended with XL710, i350, or x540 in Storage Center
VMWare ESXi 6.5 QLogic QL41xxx 1.0.22.0-1 - 14.03.03 7.4.x No Not recommended with XL710, i350, or x540 in Storage Center
VMWare ESXi 6.7 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.3.x No Not recommended with XL710, i350, or x540 in Storage Center
VMWare ESXi 6.7 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.4.x No Not recommended with XL710, i350, or x540 in Storage Center
Software iSCSI initiators (SC and SCv Series)
70 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4.3.2 Software iSCSI initiators (SC and SCv Series) Software iSCSI initiators are typically provided by the host OS vendor and can be used with any industry-standards-based network interface controller
(NIC). The following table provides guidance on which software iSCSI initiators have been tested and the support level for advanced features, such as
boot from SAN.
If boot from SAN functionality is desired, it is advised that the design include one of the Adapters listed in section 4 to ensure the indicated support
level.
Operating System SC Version BfS Notes
Citrix XenServer 6.5 6.7.x No
Citrix XenServer 6.5 7.1.x No
Citrix XenServer 7.0 7.1.x No
Citrix XenServer 7.0 7.2.x No
Citrix XenServer 7.1 7.2.x No
Citrix XenServer 7.2 7.2.x No
Citrix XenServer 7.2 7.3.x Yes
Citrix XenServer 7.4 7.3.x No
Citrix XenServer 7.6 7.4.x No
Citrix Hypervisor (XenServer) 8.0 7.3.x No
Citrix Hypervisor (XenServer) 8.0 7.4.x No
HP HP-UX 11iv3 6.7.x No
HP HP-UX 11iv3 7.1.x No
HP HP-UX 11iv3 7.2.x No
HP HP-UX 11iv3 7.3.x No
HP HP-UX 11iv3 7.4.x No
IBM AIX 6.1 6.7.x No
IBM AIX 6.1 7.1.x No
IBM AIX 6.1 7.2.x No
IBM AIX 6.1 7.3.x No
IBM AIX 7.1 6.7.x No
IBM AIX 7.1 7.1.x No
Software iSCSI initiators (SC and SCv Series)
71 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System SC Version BfS Notes
IBM AIX 7.1 7.2.x No
IBM AIX 7.1 7.3.x No
IBM AIX 7.2 6.7.x No
IBM AIX 7.2 7.1.x No
IBM AIX 7.2 7.2.x No
IBM AIX 7.2 7.3.x No
Microsoft 2008 Windows Server R2 SP1 6.7.x Yes
Microsoft 2008 Windows Server R2 SP1 7.1.x Yes
Microsoft 2008 Windows Server R2 SP1 7.2.x Yes
Microsoft 2008 Windows Server R2 SP1 7.3.x Yes
Microsoft 2012 Windows Server 6.7.x Yes
Microsoft 2012 Windows Server 7.1.x Yes
Microsoft 2012 Windows Server 7.2.x Yes
Microsoft 2012 Windows Server 7.3.x Yes
Microsoft 2012 Windows Server R2 6.7.x Yes
Microsoft 2012 Windows Server R2 7.1.x Yes
Microsoft 2012 Windows Server R2 7.2.x Yes
Microsoft 2012 Windows Server R2 7.3.x Yes
Microsoft 2012 Windows Server R2 7.4.x No
Microsoft 2016 Windows Server 6.7.x Yes
Microsoft 2016 Windows Server 7.1.x Yes
Microsoft 2016 Windows Server 7.2.x Yes
Microsoft 2016 Windows Server 7.3.x Yes
Microsoft 2016 Windows Server 7.4.x No
Microsoft 2019 Windows Server 7.3.x No
Microsoft 2019 Windows Server 7.4.x No
Novell SLES 11 SP3 6.7.x Yes
Novell SLES 11 SP3 7.1.x Yes
Novell SLES 11 SP3 7.2.x Yes
Novell SLES 11 SP4 6.7.x No
Novell SLES 11 SP4 7.1.x No
Software iSCSI initiators (SC and SCv Series)
72 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System SC Version BfS Notes
Novell SLES 11 SP4 7.2.x No
Novell SLES 11 SP4 7.3.x No
Novell SLES 11 SP4 7.4.x No
Novell SLES 12 6.7.x No
Novell SLES 12 7.1.x Yes
Novell SLES 12 7.2.x Yes
Novell SLES 12 7.3.x Yes
Novell SLES 12 SP1 6.7.x No
Novell SLES 12 SP1 7.1.x No
Novell SLES 12 SP1 7.2.x No
Novell SLES 12 SP1 7.3.x No
Novell SLES 12 SP1 7.4.x No
Novell SLES 15 7.3.x No
Novell SLES 15 7.4.x No
Oracle Linux Server 6.x UEK 6.7.x No
Oracle Linux Server 7.x UEK 6.7.x No
Oracle Linux Server 7.x UEK 7.1.x No
Oracle Linux Server 7.x UEK 7.2.x No
Oracle Linux Server 7.x UEK 7.3.x No
Oracle Linux Server 7.x UEK 7.4.x No
Oracle OVM 3.4.x 7.3.x No
Oracle OVM 3.4.x 7.4.x No
Oracle Solaris 10 SPARC 6.7.x No
Oracle Solaris 10 SPARC 7.1.x No
Oracle Solaris 10 x86_64 6.7.x No
Oracle Solaris 10 x86_64 7.1.x No
Oracle Solaris 11 SPARC 6.7.x No
Oracle Solaris 11 SPARC 7.1.x No
Oracle Solaris 11 x86_64 7.1.x No
Oracle Solaris 11 x86_64 7.2.x No
Oracle Solaris 11 x86_64 7.3.x No
Software iSCSI initiators (SC and SCv Series)
73 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System SC Version BfS Notes
Red Hat RHEL 6.x 6.7.x Yes
Red Hat RHEL 6.x 7.1.x Yes
Red Hat RHEL 6.x 7.2.x Yes
Red Hat RHEL 6.x 7.3.x Yes
Red Hat RHEL 6.x 7.4.x No
Red Hat RHEL 7.x 6.7.x Yes
Red Hat RHEL 7.x 7.1.x Yes
Red Hat RHEL 7.x 7.2.x Yes
Red Hat RHEL 7.x 7.3.x No
Red Hat RHEL 7.x 7.4.x No
Red Hat RHEL 8.x 7.3.x No
Red Hat RHEL 8.x 7.4.x No
Ubuntu 18.4 7.3.x No
Ubuntu 18.4 7.4.x No
VMWare ESXi 5.5 6.7.x Yes
VMWare ESXi 5.5 7.1.x Yes
VMWare ESXi 5.5 7.2.x Yes
VMWare ESXi 5.5 7.3.x Yes
VMWare ESXi 6.0 6.7.x Yes
VMWare ESXi 6.0 7.1.x Yes
VMWare ESXi 6.0 7.2.x Yes
VMWare ESXi 6.0 7.3.x Yes
VMWare ESXi 6.5 6.7.x Yes
VMWare ESXi 6.5 7.1.x No
VMWare ESXi 6.5 7.2.x No
VMWare ESXi 6.5 7.3.x Yes
VMWare ESXi 6.5 7.4.x No
VMWare ESXi 6.7 7.2.x No
VMWare ESXi 6.7 7.3.x No
VMWare ESXi 6.7 7.4.x No
VMWare ESXi 6.0 7.1.x Yes
Software iSCSI initiators (SC and SCv Series)
74 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System SC Version BfS Notes
VMWare ESXi 6.0 7.2.x Yes
VMWare ESXi 6.0 7.3.x Yes
VMWare ESXi 6.0 7.4.x No
VMWare ESXi 6.5 6.7.x Yes
VMWare ESXi 6.5 7.1.x No
VMWare ESXi 6.5 7.2.x No
VMWare ESXi 6.5 7.3.x Yes
VMWare ESXi 6.5 7.4.x No
VMWare ESXi 6.7 7.2.x No
VMWare ESXi 6.7 7.3.x No
VMWare ESXi 6.7 7.4.x No
iSCSI converged network and host bus adapters (PS Series)
75 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4.3.3 iSCSI converged network and host bus adapters (PS Series) Configurations listed in this section are supported at Level 1 (as described previously) for the listed switch firmware/array firmware combinations.
Switch validation reflects only those switches that connect directly to the array ports. There is no validation for other upstream switches. Feature and
other support levels are indicated where they differ from the default Level 1 support.
Note: Unless otherwise noted, the OS-provided native multipath IO functionality is used for all validations listed.
Vendor OS Version CNA Vendor
Model Driver Boot Code Firmware Array OS
BfS DCB Notes
Microsoft Windows Server 2008 R2
Broadcom BRCM570x 5.2.14.0 N/A N/A 4.0.x L1 N/A
Microsoft Windows Server 2008 R2
Broadcom 6.2.7.0 N/A N/A 6.0.x L1 N/A
Microsoft Windows Server 2008 R2
Broadcom 7.10.0.0 7.10.0 7.10.18 8.1.x L1 N/A
Microsoft Windows Server 2008 R2
QLogic BCM577xx 5.2.11.0 N/A N/A 4.0.x L1 N/A
Microsoft Windows Server 2008 R2
QLogic 7.2.5.0 N/A N/A 6.0.x L1 N/A
Microsoft Windows Server 2008 R2
QLogic BCM578xx 7.2.12.0 N/A N/A 6.0.x L1 L3
Microsoft Windows Server 2008 R2
QLogic 7.0.x L1 L1
Microsoft Windows Server 2008 R2
QLogic 7.1.x L1 L1
iSCSI converged network and host bus adapters (PS Series)
76 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor OS Version CNA Vendor
Model Driver Boot Code Firmware Array OS
BfS DCB Notes
Microsoft Windows Server 2008 R2
QLogic BCM578xx 7.2.12.0 N/A N/A 8.x L1 L1
Microsoft Windows Server 2008 R2
QLogic 7.10.0.0 7.10.0 7.10.18 8.x L1 L1
Microsoft Windows Server 2008 R2
QLogic QLx405x 2.1.4.26 N/A 3.0.1.53 3.2.8 L1 N/A
Microsoft Windows Server 2012 R2
Broadcom BCM570x 7.12.0.0 7.12.1 7.12.19 9.x L1 N/A
Microsoft Windows Server 2012 R2
Broadcom BCM570x 7.12.0.0 7.12.1 7.12.19 10.0.x L1 N/A
Microsoft Windows Server 2012 R2
Broadcom BCM577xx 7.12.0.0 7.12.1 7.12.19 9.x L1 N/A
Microsoft Windows Server 2012 R2
Broadcom BCM571xx 7.12.0.0 7.12.1 7.12.19 10.x L1 N/A
Microsoft Windows Server 2012 R2
Broadcom BCM578xx 7.12.0.0 7.12.1 7.12.19 10.x L1 N/A
Microsoft Windows Server 2016
Broadcom BCM578xx 7.13.57.103 7.12.1 8.07.25 10.x L1
Microsoft Windows Server 2012 R2
Emulex OCx1410x 10.6.116.0 10.6.133.10 10.6.144.21 9.x L1 L1
Microsoft Windows Server 2012 R2
QLogic BCM578xx 7.8.76.0 7.8.51 7.8.53 7.0.x L1 L1 HP 534
Microsoft Windows Server 2012 R2
QLogic BCM578xx 7.1.x L1 L1
Microsoft Windows Server 2012 R2
QLogic BCM578xx 8.x L1 L1
iSCSI converged network and host bus adapters (PS Series)
77 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor OS Version CNA Vendor
Model Driver Boot Code Firmware Array OS
BfS DCB Notes
Microsoft Windows Server 2012 R2
QLogic BCM578xx 7.10.0.0 7.10.0 7.10.18 8.1.x L1 L1
Microsoft Windows Server 2012 R2
QLogic QLx82xx 2.1.5.38 2.0.1.35 2.10.37 9.x L1 L1
Novell SUSE Linux Ent. SRV 11
Broadcom BRCM570x 2.0.4 N/A N/A 5.2.x L3 N/A
Novell SUSE Linux Ent. SRV 11
Broadcom 2.1.11 N/A N/A 6.0.x L3 N/A
Novell SUSE Linux Ent. SRV 11
Broadcom BRCM570x 2.7..10.1b 7.10.0 7.10.18 8.0 L3 N/A
Novell SUSE Linux Ent. SRV 11 SP3
Broadcom BRCM570x 2.7..10.1b 7.10.0 7.10.18 10.0.x L3 N/A
Novell SUSE Linux Ent. SRV 11 SP3
Broadcom BRCM570x 2.7..10.1b 7.10.0 7.10.18 10.0.x L3 N/A
Novell SUSE Linux Ent. SRV 11
Emulex OCx1410x 10.6.133.15 10.6.133.10 10.6.133.18 9.x L1 L1
Novell SUSE Linux Ent. SRV 11 SP3
Emulex OCx1410x 10.6.133.15 10.6.133.10 10.6.133.18 10.x L1 L1
Novell SUSE Linux Ent. SRV 11
QLogic BRCM577xx 2.1.11 N/A N/A 6.0.x L3 N/A
Novell SUSE Linux Ent. SRV 11
QLogic 2.7.6.2 7.10.0 7.10.18 7.0.x L1 N/A
Novell SUSE Linux Ent. SRV 11
QLogic 7.1.x L1 N/A
Novell SUSE Linux Ent. SRV 11
QLogic 7.12.19 9.x L1 L1
iSCSI converged network and host bus adapters (PS Series)
78 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor OS Version CNA Vendor
Model Driver Boot Code Firmware Array OS
BfS DCB Notes
Novell SUSE Linux Ent. SRV 11
QLogic BRCM578xx 1.78.00 7.12.5 7.12.19 9.x L1 L1
Novell SUSE Linux Ent. SRV 11
QLogic BRCM578xx 2.7.10.1b 7.10.11 7.10.18 8.0 L3 N/A
Novell SUSE Linux Ent. SRV 11
QLogic BRCM578xx 2.7.6.2 7.10.0 7.10.18 8.1.x L1 L1
Novell SUSE Linux Ent. SRV 11
QLogic BRCM578xx 7.12.5 7.12.19 9.x L1 L1
Novell SUSE Linux Ent. SRV 11
QLogic BRCM570x 2.7.6.2 7.12.5 7.12.19 10.x L1 L1
Novell SUSE Linux Ent. SRV 11
QLogic BRCM578x 2.7.6.2 7.12.5 7.12.19 10.x L1 L1
Novell SUSE Linux Ent. SRV 11
QLogic QLx82xx 5.04.01.09.00.00-k0
2.0.1.35 2.10.37 9.x L1 L3
Novell SUSE Linux Ent. SRV 11 SP3
QLogic QLx82xx 5.04.01.09.00.00-k0
2.0.1.35 2.10.37 10.x L1 L3
Novell SUSE Linux Ent. SRV 11 SP4
QLogic QLx82xx 5.04.01.09.00.00-k0
2.0.1.35 2.10.37 10.x L1 L3
Novell SUSE Linux Ent. SRV 12
QLogic BCM578xx 2.7.6.2 7.10.0 7.10.18 8.1.x L1 L1
Novell SUSE Linux Ent. SRV 12
QLogic 7.12.5 7.12.19 9.x L1 L1
Novell SUSE Linux Ent. SRV 12
QLogic BCM578xx 1.712.36 7.12.5 8.07.25 10.x L1 L1
Novell SUSE Linux Ent. SRV 12
QLogic BCM571xx 1.712.36 7.12.5 8.07.25 10.x L1 L1
iSCSI converged network and host bus adapters (PS Series)
79 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor OS Version CNA Vendor
Model Driver Boot Code Firmware Array OS
BfS DCB Notes
Oracle Linux Server (UEK) 6.6
QLogic BCM578xx 2.11.2.0 7.12.5 7.12.19 8.1.x L1 L3
Oracle Linux Server (UEK) 6.6
QLogic 9.x L1 L3
Oracle Linux Server (UEK) 6.7
QLogic BRCM570x 2.11.2.0 7.12.5 7.12.19 10.x L1 L3
Oracle Linux Server (UEK) 6.7
QLogic BRCM571x 2.11.2.0 7.12.5 7.12.19 10.x L1 L3
Oracle Linux Server (UEK) 6.7
QLogic BRCM578x 2.11.2.0 7.12.5 7.12.19 10.x L1 L3
Oracle Linux Server (UEK) 7.0
QLogic BCM578xx 2.11.2.0 2.8.25 7.12.17 9.x L1 L3
Oracle Solaris 9-SPARC QLogic QLx405x 2.1.4.26 N/A 3.0.1.53 3.2.8 L1 N/A
Oracle Solaris 9-SPARC QLogic QLx406x 2.1.4.26 N/A 3.0.1.53 3.2.8 L1 N/A
RedHat Enterprise Linux 6.5
QLogic BCM577xx 2.7.6.2 7.8.51 7.8.53 7.0.x L1 N/A
RedHat Enterprise Linux 6.5
QLogic 7.1.x L1 N/A
RedHat Enterprise Linux 6.6
Broadcom BRCM570x 2.7.10.1 7.10.0 7.10.18 8.1.x L1 N/A
RedHat Enterprise Linux 6.6
QLogic BCM578xx 2.7.10.1 7.10.0 7.10.18 8.1.x L1 L1
RedHat Enterprise Linux 6.7
QLogic BRCM570x 2.7.10.1 7.10.0 7.10.18 10.x L1 L1
iSCSI converged network and host bus adapters (PS Series)
80 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor OS Version CNA Vendor
Model Driver Boot Code Firmware Array OS
BfS DCB Notes
RedHat Enterprise Linux 6.8
QLogic BCM578xx 2.7.10.1 7.10.0 7.10.18 10.x L1 L1
RedHat Enterprise Linux 6.8
QLogic BRCM570x 2.7.10.1 7.10.0 7.10.18 10.x L1 L1
RedHat Enterprise Linux 7.0
QLogic BCM578xx 2.7.6.2 7.10.0 7.10.18 8.1.x L1 L1
RedHat Enterprise Linux 7.0
QLogic BCM578xx 2.11.0.0 7.12.5 7.12.19 9.x L1 L1
RedHat Enterprise Linux 7.1
QLogic BCM578xx 1.712.51 7.12.5 7.12.19 10.x L1 L1
RedHat Enterprise Linux 7.3
QLogic BCM578xx 1.712.51 7.12.5 7.12.19 10.x L1 L1
VMware ESX/ESXi 5.5 Emulex OCe1410x 10.2.309.6 10.2.506.19 10.2.506.19 8.1.x L1 L2
VMware ESX/ESXi 5.5 QLogic BCM578xx 1.78.11v55.4
N/A N/A 7.0.x L3 L2
VMware ESX/ESXi 5.5 QLogic 7.1.x L1 N/A
VMware ESX/ESXi 5.5 QLogic QxE82xx
634.55.23.0-1OEM
2.19 4.16.17 7.0.x L1 L3
VMware ESX/ESXi 5.5 QLogic 7.1.x L1 N/A
VMware ESX/ESXi 6.0 QLogic QxE82xx 634.55.23.0-1OEM
2.19 4.16.17 10.x L1 N/A
VMware ESX/ESXi 6.0 Broadcom BRCM570x 2.78.76.v60.8-1
7.10.0 7.10.18 7.0.x L1 N/A
VMware ESX/ESXi 6.0 Broadcom 7.1.x L1 N/A
VMware ESX/ESXi 6.0 Broadcom 8.0.x L1 N/A
iSCSI converged network and host bus adapters (PS Series)
81 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor OS Version CNA Vendor
Model Driver Boot Code Firmware Array OS
BfS DCB Notes
VMware ESX/ESXi 6.0 Broadcom BCM578xx 2.78.76.v60.8-1
7.10.0 7.10.18 10.x L1 N/A
VMware ESX/ESXi 6.0 Emulex OCe1410x 10.2.309.6 10.2.506.19 10.2.506.19 8.1.x L1 L2
VMware ESX/ESXi 6.0 Emulex OCe1410x 10.2.309.6 10.2.506.19 10.2.506.19 10.x L1 L2
VMware ESX/ESXi 6.0 QLogic BCM578xx 2.78.76.v60.8-1
7.10.11 7.10.18 7.0.x L1 N/A
VMware ESX/ESXi 6.0 QLogic 7.1.x L1 N/A
VMware ESX/ESXi 6.0 QLogic 8.0.x L1 N/A
VMware ESX/ESXi 6.5 Emulex OCe1410x 10.2.309.6 10.2.506.19 10.2.506.19 10.x L1 L2
VMware ESX/ESXi 6.5 QLogic BCM578xx 2.713.10.v60.4
7.10.11 8.07.25 10.0.x L1 N/A
Network interface cards for boot from SAN and DCB support for iSCSI (PS Series)
82 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4.3.4 Network interface cards for boot from SAN and DCB support for iSCSI (PS Series) Network interface controllers (NIC) are the simplest class of host connectivity interfaces and provide basic Ethernet and TCP/IP functionality to the
server. For storage solutions, this class of Adapters must be paired with special software within the host server operating system called a storage
initiator. Dell will support any industry standards based NIC with the software iSCSI initiators listed in section 4.
The devices below have each been tested and are supported for boot from SAN functionality
Vendor OS Version NIC Vendor Model Features Notes
BfS DCB
Microsoft Windows Server 2008 R2 Broadcom BRCM570x L1 N/A
Microsoft Windows Server 2008 R2 BRCM577xx L1 N/A
Microsoft Windows Server 2008 R2 Intel i350 L1 N/A
Microsoft Windows Server 2008 R2 Pro1000 L1 N/A
Microsoft Windows Server 2008 R2 X5xx Family L1 L1
Microsoft Windows Server 2008 R2 QLogic BRCM578xx L1 L1 HP 534
Microsoft Windows Server 2012 Broadcom BRCM570x L1 N/A
Microsoft Windows Server 2012 BRCM577xx L1 N/A
Microsoft Windows Server 2012 Intel X5xx Family L1 L1
Microsoft Windows Server 2012 i350 L1 N/A
Microsoft Windows Server 2012 QLogic BRCM578xx L1 L3 HP 534
Microsoft Windows Server 2012 R2 Broadcom BRCM570x L1 N/A
Microsoft Windows Server 2012 R2 BRCM577xx L1 N/A
Microsoft Windows Server 2012 R2 Emulex OCx1410x L1 L3
Microsoft Windows Server 2012 R2 X5xx Family L1 L1
Network interface cards for boot from SAN and DCB support for iSCSI (PS Series)
83 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor OS Version NIC Vendor Model Features Notes
BfS DCB
Microsoft Windows Server 2012 R2 Intel i350 L1 N/A
Microsoft Windows Server 2012 R2 QLogic QLx82xx L1 L3
Novell SUSE Linux Ent. SRV 11 SP3
Broadcom BRCM570x L1 N/A
Novell SUSE Linux Ent. SRV 11 SP3
Intel X5xx Family L1 L3
Novell SUSE Linux Ent. SRV 11 SP3
QLogic BRCM578xx L1 L3
Novell SUSE Linux Ent. SRV 12 Broadcom BRCM570x L1 N/A
Novell SUSE Linux Ent. SRV 12 Intel X5xx Family L1 L3
Novell SUSE Linux Ent. SRV 12 QLogic BRCM578xx L1 L3
Oracle Linux (UEK) 6.4 Broadcom BRCM570x L1 N/A
Oracle Linux (UEK) 6.4 BRCM578xx L1 N/A HP 534
Oracle Linux (UEK) 6.5 BRCM570x L1 N/A
Oracle Linux (UEK) 6.5 BRCM577xx L1 N/A
Oracle Linux (UEK) 6.6 BRCM570x L1 N/A
Oracle Linux (UEK) 6.6 QLogic BRCM578xx L1 N/A
RedHat Enterprise Linux 6.4 Broadcom BRMC578xx L1 L1 HP 534
RedHat Enterprise Linux 6.5 Intel i350 L1 L3
RedHat Enterprise Linux 6.5 X5xx Family L1 L3
RedHat Enterprise Linux 7.0 Broadcom BRCM570x L1 N/A
RedHat Enterprise Linux 7.0 Intel X5xx Family L1 L3
RedHat Enterprise Linux 7.0 QLogic BRCM578xx L1 N/A
Network interface cards for boot from SAN and DCB support for iSCSI (PS Series)
84 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor OS Version NIC Vendor Model Features Notes
BfS DCB
VMware ESX/ESXi 5.5 Broadcom BRCM57xx L1 N/A
VMware ESX/ESXi 5.5 BRCM577xx L1 L3
VMware ESX/ESXi 5.5 Intel X5xx Family L1 N/A
VMware ESX/ESXi 5.5 QLogic BRCM578xx L1 N/A HP 534
VMware ESX/ESXi 6.0 Broadcom BRCM570x L1 N/A
VMware ESX/ESXi 6.0 Intel X5xx Family L1 N/A
VMware ESX/ESXi 6.0 QLogic BRCM578xx L1 N/A
Software iSCSI initiators (PS Series)
85 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4.3.5 Software iSCSI initiators (PS Series) Software iSCSI initiators are typically provided by the host OS vendor and can be used with any industry-standards-based network interface controller
(NIC). The following table provides guidance on which software iSCSI initiators have been tested with each platform and the support level for
advanced features, such as boot from SAN and data center bridging (DCB) functionality. It should be noted that Microsoft Windows and Red Hat
Enterprise Linux provide some level of software DCB functionality, but it has not been tested by Dell and is supported on an L3 basis. If DCB is
needed to allow for a converged SAN/LAN network, it is preferable that an iSCSI CNA with iSCSI Hardware Offload capability be used.
If boot from SAN functionality is desired, it is advised that the design include one of the Adapters listed in section 4 to ensure the indicated support
level.
Vendor iSCSI Initiator/ Operating System Initiator Version PS Series OS Version DCB BfS
Citrix XenServer 6.x 6.0.2 6.0.x N/A L3
Citrix XenServer 6.x 6.2.x 6.0.x, 7.0.x, 7.1.x N/A L3
Microsoft Windows Server 2008 R2 6.1.7600.16385 3.2.8+, 4.x, 5.x, 6.0.x N/A L1
Microsoft Windows Server 2008 R2 6.1.7601.17514 3.2.8+, 4.x, 5.x, 6.0.x, 7.0.x, 7.1.x, 8.0, 8.1, 9.x
N/A L1
Microsoft Windows Server 2012 6.2.8370.0 5.2.x2, 6.0.x, 7.0.x L3 L1
Microsoft Windows Server 2012 6.2.9200.16451 6.0.x, 7.0.x, 7.1.x, 8.0, 8.1, 9.x, 10.x L3 L1
Microsoft Windows Server 2012 R2 6.3.9600.16384 6.0.x, 7.0.x, 7.1.x, 8.0.x, 8.1, 9.x, 10.x
L3 L1
Novell SUSE Linux Enterprise Server 11 2.0-870 3.2.8+, 4.x, 5.x N/A L3
Novell SUSE Linux Enterprise Server 11 2.0-873 7.0.x, 8.0.x, 8.1, 9.x, 10x. N/A L3
Novell SUSE Linux Enterprise Server 12 2.0-873 7.0.x, 7.1.x, 8.0.x, 8.1, 9.x, 10.x N/A L3
Oracle Enterprise Linux Server 6 6 5.0.2+ N/A L3
Oracle Enterprise Linux Server 6 6.2.0-873.13.0.1 8.0, 8.1, 9.x N/A L1
Oracle Linux Server UEK 6.5 6.2.0-873.10.0.0 7.0.x, 7.1.x N/A L1
Software iSCSI initiators (PS Series)
86 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor iSCSI Initiator/ Operating System Initiator Version PS Series OS Version DCB BfS
Oracle Linux Server UEK 6.5 6.2.0-873.13.0.1 8.0, 8.1, 9.x N/A L1
Oracle Linux Server UEK 7.0 6.2.0.873-14 8.0, 8.1, 9.x N/A L3
RedHat Enterprise Linux Server 6 6.2.0.872-10 4.x, 5.x, 6.x N/A L1
RedHat Enterprise Linux Server 6 6.2.0.872-33 4.x, 5.x, 6.x L3 L1
RedHat Enterprise Linux Server 6 6.2.0.872-41 4.x, 5.x, 6.x L3 L1
RedHat Enterprise Linux Server 6 6.2.0.873-2 4.x, 5.x, 6.x L3 L1
RedHat Enterprise Linux Server 6 6.2.0.873-13 8.0.x, 8.1.x L3 L1
RedHat Enterprise Linux Server 7 6.2.0.873-21 7.0.x, 7.1.x, 8.0.x, 8.1, 9.x, 10.x L3 L1
VMware ESX/ESXi 5.5 In-Box 6.0.x, 7.0.x, 7.1.x, 8.1, 9.x N/A L1
VMware ESX/ESXi 6.0 In-Box 7.0.x, 7.1.x, 8.0.x, 8.1.x, 9.x, 10.x N/A L1
SAS Adapters (SC and SCv Series)
87 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4.4 SAS Adapters (SC and SCv Series) The following table lists serial attached SCSI (SAS) HBAs that have been tested with the SC and SCv Series of array products. SAS HBAs, other than
those listed below, are NOT supported by Dell at this time. Boot from SAN (BfS) is not supported.
Note: Windows Storage Server 2012 and higher follow the same characteristics and support of Windows Server 2012 and higher.
Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes
Microsoft 2008 Windows Server R2 SP1
Dell 12G SAS Adapter 2.50.75.01 03.00.08.00 6.7.x Not Supported
Microsoft 2008 Windows Server R2 SP1
Dell 12G SAS Adapter 2.50.92.0 09.00.09.00-IT 7.1.x Not Supported
Dell fw kit: 9.17.20.07,A01
Microsoft 2008 Windows Server R2 SP1
Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
Microsoft 2008 Windows Server R2 SP1
Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.3.x Not Supported
Dell fw kit: 13.17.03.00_A03
Microsoft 2008 Windows Server R2 SP1
Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.1.x Not Supported
Dell fw kit: 9.17.20.07,A01
Microsoft 2008 Windows Server R2 SP1
Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.2.x Not Supported
Dell fw kit: 9.17.20.07,A01
Microsoft 2008 Windows Server R2 SP1
LSI 9300-8e 2.50.80.0 03.00.08.00 7.2.x Not Supported
Microsoft 2008 Windows Server R2 SP1
LSI 9300-8e 2.50.80.0 13.00.00.00-IT 7.2.x Not Supported
Microsoft 2008 Windows Server R2 SP1
LSI 9300-8e 2.50.80.0 13.00.00.00-IT 7.3.x Not Supported
Microsoft 2008 Windows Server R2 SP1
LSI 9300-8e 2.50.80.0 15.00.00.00-IT 7.2.x Not Supported
Microsoft 2008 Windows Server R2 SP1
LSI 9300-8e 2.50.80.0 15.00.00.00-IT 7.4.x Not Supported
Microsoft 2012 Windows Server
Dell 12G SAS Adapter 2.50.75.01 03.00.08.00 6.7.x Not Supported
Microsoft 2012 Windows Server
Dell 12G SAS Adapter 2.50.75.01 09.00.09.00-IT 7.1.x Not Supported
Dell fw kit: 9.17.20.07,A01
SAS Adapters (SC and SCv Series)
88 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes
Microsoft 2012 Windows Server
Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
Microsoft 2012 Windows Server
Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.3.x Not Supported
Dell fw kit: 13.17.03.00_A03
Microsoft 2012 Windows Server
Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.1.x Not Supported
Dell fw kit: 9.17.20.07,A01
Microsoft 2012 Windows Server
Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.2.x Not Supported
Dell fw kit: 9.17.20.07,A01
Microsoft 2012 Windows Server
Dell 12G SAS Adapter 2.51.15.0 15.17.09.06 7.3.x Not Supported
Dell fw kit: 15.17.09.06_A07
Microsoft 2012 Windows Server
Dell 12G SAS Adapter 2.51.15.0 16.17.00.03 7.4.x Not Supported
Microsoft 2012 Windows Server R2
Dell 12G SAS Adapter 2.50.75.01 03.00.08.00 6.7.x Not Supported
Microsoft 2012 Windows Server R2
Dell 12G SAS Adapter 2.50.75.01 09.00.09.00-IT 7.1.x Not Supported
Dell fw kit: 9.17.20.07,A01
Microsoft 2012 Windows Server R2
Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
Microsoft 2012 Windows Server R2
Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.3.x Not Supported
Dell fw kit: 13.17.03.00_A03
Microsoft 2012 Windows Server R2
Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.1.x Not Supported
Dell fw kit: 9.17.20.07,A01
Microsoft 2012 Windows Server R2
Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.2.x Not Supported
Dell fw kit: 9.17.20.07,A01
Microsoft 2012 Windows Server R2
LSI 9300-8e 2.50.80.1 03.00.08.00 7.2.x Not Supported
Microsoft 2012 Windows Server R2
LSI 9300-8e 2.50.80.1 13.00.00.00-IT 7.2.x Not Supported
Microsoft 2012 Windows Server R2
LSI 9300-8e 2.50.80.1 13.00.00.00-IT 7.3.x Not Supported
Microsoft 2012 Windows Server R2
LSI 9300-8e 2.50.80.1 15.00.00.00-IT 7.2.x Not Supported
Microsoft 2012 Windows Server R2
LSI 9300-8e 2.50.80.1 15.00.00.00-IT 7.4.x Not Supported
SAS Adapters (SC and SCv Series)
89 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes
Microsoft 2016 Windows Server
Dell 12G SAS Adapter 2.51.15.0 13.00.00.00-IT 7.1.x Not Supported
Dell fw kit: 13.17.03.00_A03
Microsoft 2016 Windows Server
Dell 12G SAS Adapter 2.51.15.0 13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
Microsoft 2016 Windows Server
Dell 12G SAS Adapter 2.51.15.0 13.00.00.00-IT 7.3.x Not Supported
Dell fw kit: 13.17.03.00_A03
Microsoft 2016 Windows Server
Dell 12G SAS Adapter 2.51.21.1 15.17.09.06 7.3.x Not Supported
Dell fw kit: 15.17.09.06_A07
Microsoft 2016 Windows Server
Dell 12G SAS Adapter 2.51.25.1 16.17.00.03 7.4.x Not Supported
Microsoft 2016 Windows Server
LSI 9300-8e 2.51.12.80 03.00.08.00 7.2.x Not Supported
Microsoft 2016 Windows Server
LSI 9300-8e 2.51.12.80 13.00.00.00-IT 7.2.x Not Supported
Microsoft 2016 Windows Server
LSI 9300-8e 2.51.12.80 13.00.00.00-IT 7.3.x Not Supported
Microsoft 2016 Windows Server
LSI 9300-8e 2.51.12.80 15.00.00.00-IT 7.2.x Not Supported
Microsoft 2016 Windows Server
LSI 9300-8e 2.51.12.80 15.00.00.00-IT 7.4.x Not Supported
Microsoft 2019 Windows Server
Dell 12G SAS Adapter 2.51.24.80 16.17.00.03 7.3.x Not Supported
Microsoft 2019 Windows Server
Dell 12G SAS Adapter 2.51.24.80 16.17.00.03 7.4.x Not Supported
Red Hat RHEL 6.x Dell 12G SAS Adapter 04.100.00.00-rh 13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
Red Hat RHEL 6.x Dell 12G SAS Adapter 04.100.00.00-rh 09.00.09.00-IT 7.1.x Not Supported
Dell fw kit: 9.17.20.07,A01
Red Hat RHEL 6.x Dell 12G SAS Adapter 04.100.00.00-rh 09.00.09.00-IT 7.2.x Not Supported
Dell fw kit: 9.17.20.07,A01
Red Hat RHEL 6.x Dell 12G SAS Adapter 14.101.00.00-rh 13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
Red Hat RHEL 6.x Dell 12G SAS Adapter 14.101.00.00-rh 13.00.00.00-IT 7.3.x Not Supported
Dell fw kit: 13.17.03.00_A03
SAS Adapters (SC and SCv Series)
90 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes
Red Hat RHEL 6.x Dell 12G SAS Adapter OS Built-In 03.00.08.00 6.7.x Not Supported
Red Hat RHEL 6.x Dell 12G SAS Adapter 22.00.04.00 15.17.09.06 7.3.x Not Supported
Dell fw kit: 15.17.09.06_A07
Red Hat RHEL 6.x Dell 12G SAS Adapter 27.00.01.00 15.17.09.06 7.3.x Not Supported
Dell fw kit: 15.17.09.06_A07
Red Hat RHEL 6.x Dell 12G SAS Adapter 27.00.01.00 16.17.00.03 7.4.x Not Supported
Red Hat RHEL 6.x LSI 9300-8e 09.102.00.00-rh 03.00.08.00 7.2.x Not Supported
Red Hat RHEL 6.x LSI 9300-8e 09.102.00.00-rh 13.00.00.00-IT 7.2.x Not Supported
Red Hat RHEL 6.x LSI 9300-8e 09.102.00.00-rh 13.00.00.00-IT 7.3.x Not Supported
Red Hat RHEL 6.x LSI 9300-8e 09.102.00.00-rh 15.00.00.00-IT 7.2.x Not Supported
Red Hat RHEL 6.x LSI 9300-8e 14.101.00.00-rh 13.00.00.00-IT 7.3.x Not Supported
Red Hat RHEL 6.x LSI 9300-8e 14.101.00.00-rh 15.00.00.00-IT 7.4.x Not Supported
Red Hat RHEL 7.x Dell 12G SAS Adapter 04.100.00.00-rh 13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
Red Hat RHEL 7.x Dell 12G SAS Adapter 04.100.00.00-rh 09.00.09.00-IT 7.1.x Not Supported
Dell fw kit: 9.17.20.07,A01
Red Hat RHEL 7.x Dell 12G SAS Adapter 04.100.00.00-rh 09.00.09.00-IT 7.2.x Not Supported
Dell fw kit: 9.17.20.07,A01
Red Hat RHEL 7.x Dell 12G SAS Adapter 15.100.00.00 13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
Red Hat RHEL 7.x Dell 12G SAS Adapter 15.100.00.00 13.00.00.00-IT 7.3.x Not Supported
Dell fw kit: 13.17.03.00_A03
Red Hat RHEL 7.x Dell 12G SAS Adapter OS Built-In 03.00.08.00 6.7.x Not Supported
Red Hat RHEL 7.x Dell 12G SAS Adapter 16.100.00.00 15.17.09.06 7.3.x Not Supported
Dell fw kit: 15.17.09.06_A07
SAS Adapters (SC and SCv Series)
91 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes
Red Hat RHEL 7.x Dell 12G SAS Adapter 16.100.00.00 16.17.00.03 7.4.x Not Supported
Red Hat RHEL 7.x Dell 12G SAS Adapter 27.00.01.00 15.17.09.06 7.3.x Not Supported
Dell fw kit: 15.17.09.06_A07
Red Hat RHEL 7.x LSI 9300-8e 13.100.00.00-rh 03.00.08.00 7.2.x Not Supported
Red Hat RHEL 7.x LSI 9300-8e 13.100.00.00-rh 13.00.00.00-IT 7.2.x Not Supported
Red Hat RHEL 7.x LSI 9300-8e 13.100.00.00-rh 13.00.00.00-IT 7.3.x Not Supported
Red Hat RHEL 7.x LSI 9300-8e 13.100.00.00-rh 15.00.00.00-IT 7.2.x Not Supported
Red Hat RHEL 7.x LSI 9300-8e 16.100.00.00 13.00.00.00-IT 7.3.x Not Supported
Red Hat RHEL 7.x LSI 9300-8e 16.100.00.00 15.00.00.00-IT 7.4.x Not Supported
VMWare ESXi 5.5 Dell 12G SAS Adapter mpt3sas 04.00.00.00.1vmw
03.00.08.00 6.7.x Not Supported
VMWare ESXi 5.5 Dell 12G SAS Adapter mpt3sas 10.00.02.00 - 5.5
13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
VMWare ESXi 5.5 Dell 12G SAS Adapter mpt3sas 10.00.02.00 - 5.5
09.00.09.00-IT 6.7.x Not Supported
Dell fw kit: 9.17.20.07,A01
VMWare ESXi 5.5 Dell 12G SAS Adapter mpt3sas 10.00.02.00 - 5.5
09.00.09.00-IT 7.1.x Not Supported
Dell fw kit: 9.17.20.07,A01
VMWare ESXi 5.5 Dell 12G SAS Adapter mpt3sas 10.00.02.00 - 5.5
09.00.09.00-IT 7.2.x Not Supported
Dell fw kit: 9.17.20.07,A01
VMWare ESXi 5.5 Dell 12G SAS Adapter mpt3sas 13.00.00.00
13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
VMWare ESXi 5.5 Dell 12G SAS Adapter mpt3sas 13.00.00.00
13.00.00.00-IT 7.3.x Not Supported
Dell fw kit: 13.17.03.00_A03
VMWare ESXi 5.5 LSI 9300-8e mpt3sas 04.00.00.00.1vmw
03.00.08.00 7.2.x Not Supported
VMWare ESXi 5.5 LSI 9300-8e mpt3sas 04.00.00.00.1vmw
13.00.00.00-IT 7.2.x Not Supported
SAS Adapters (SC and SCv Series)
92 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes
VMWare ESXi 5.5 LSI 9300-8e mpt3sas 04.00.00.00.1vmw
13.00.00.00-IT 7.3.x Not Supported
VMWare ESXi 6.0 Dell 12G SAS Adapter mpt3sas 04.00.00.00.1vmw
03.00.08.00 6.7.x Not Supported
VMWare ESXi 6.0 Dell 12G SAS Adapter mpt3sas 10.00.02.00 - 6.0
13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
VMWare ESXi 6.0 Dell 12G SAS Adapter mpt3sas 10.00.02.00 - 6.0
09.00.09.00-IT 6.7.x Not Supported
Dell fw kit: 9.17.20.07,A01
VMWare ESXi 6.0 Dell 12G SAS Adapter mpt3sas 10.00.02.00 - 6.0
09.00.09.00-IT 7.1.x Not Supported
Dell fw kit: 9.17.20.07,A01
VMWare ESXi 6.0 Dell 12G SAS Adapter mpt3sas 10.00.02.00 - 6.0
09.00.09.00-IT 7.2.x Not Supported
Dell fw kit: 9.17.20.07,A01
VMWare ESXi 6.0 Dell 12G SAS Adapter mpt3sas 13.00.00.00
13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
VMWare ESXi 6.0 Dell 12G SAS Adapter mpt3sas 13.00.00.00
13.00.00.00-IT 7.3.x Not Supported
Dell fw kit: 13.17.03.00_A03
VMWare ESXi 6.0 Dell 12G SAS Adapter lsi_msgpt3 16.00.01.00-1vmw
15.17.09.06 7.3.x Not Supported
VMWare ESXi 6.0 Dell 12G SAS Adapter lsi_msgpt3 16.00.01.00-1vmw
16.17.00.03 7.4.x Not Supported
VMWare ESXi 6.0 LSI 9300-8e mpt3sas 04.00.00.00.1vmw
03.00.08.00 7.2.x Not Supported
VMWare ESXi 6.0 LSI 9300-8e mpt3sas 04.00.00.00.1vmw
13.00.00.00-IT 7.2.x Not Supported
VMWare ESXi 6.0 LSI 9300-8e mpt3sas 04.00.00.00.1vmw
13.00.00.00-IT 7.3.x Not Supported
VMWare ESXi 6.0 LSI 9300-8e mpt3sas 04.00.00.00.1vmw
15.00.00.00-IT 7.4.x Not Supported
VMWare ESXi 6.5 Dell 12G SAS Adapter lsi_msgpt3 12.00.02.00-11vmw
13.00.00.00-IT 7.2.x Not Supported
Dell fw kit: 13.17.03.00_A03
SAS Adapters (SC and SCv Series)
93 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes
VMWare ESXi 6.5 Dell 12G SAS Adapter lsi_msgpt3 12.00.02.00-11vmw
13.00.00.00-IT 7.3.x Not Supported
Dell fw kit: 13.17.03.00_A03
VMWare ESXi 6.5 Dell 12G SAS Adapter lsi_msgpt3 16.00.01.00-1vmw
15.17.09.06 7.3.x Not Supported
VMWare ESXi 6.5 Dell 12G SAS Adapter lsi_msgpt3 16.00.01.00-1vmw
16.17.00.03 7.4.x Not Supported
VMWare ESXi 6.5 LSI 9300-8e lsi_msgpt3 12.00.02.00-11vmw
03.00.08.00 7.2.x Not Supported
VMWare ESXi 6.5 LSI 9300-8e lsi_msgpt3 12.00.02.00-11vmw
13.00.00.00-IT 7.2.x Not Supported
VMWare ESXi 6.5 LSI 9300-8e lsi_msgpt3 12.00.02.00-11vmw
13.00.00.00-IT 7.3.x Not Supported
VMWare ESXi 6.5 LSI 9300-8e lsi_msgpt3 12.00.02.00-11vmw
15.00.00.00-IT 7.4.x Not Supported
VMWare ESXi 6.7 Dell 12G SAS Adapter lsi_msgpt3 16.00.01.00-3vmw
15.17.09.06 7.3.x Not Supported
VMWare ESXi 6.7 Dell 12G SAS Adapter lsi_msgpt3 16.00.01.00-3vmw
16.17.00.03 7.4.x Not Supported
* Adapter only supported in Dell PowerEdge 13th Generation and above server products
Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)
94 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4.5 Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)
4.5.1 FCoE converged network and host bus adapters (SC, SCv Series) Operating System FCoE Host Adapter Driver BootCode Firmware SC Version BfS Notes
Microsoft 2008 Windows Server R2 SP1
Cisco VIC-12xx 2.1.0.29 2.2(4b) 2.2(4b) 6.7.x Yes
Microsoft 2008 Windows Server R2 SP1
QLogic QxE826x 9.1.12.10 3.28 4.18.04 6.7.x Yes Dell fw kit: 2.10.29
Microsoft 2008 Windows Server R2 SP1
QLogic QxE826x 9.1.13.10 3.29 4.18.04 7.1.x Yes Dell fw kit: 02.10.37
Microsoft 2008 Windows Server R2 SP1
QLogic QxE826x 9.1.13.10 3.31 4.18.04 6.7.x Yes Dell fw kit: 02.10.38
Microsoft 2008 Windows Server R2 SP1
QLogic QxE826x 9.1.13.10 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38
Microsoft 2008 Windows Server R2 SP1
QLogic QxE826x 9.1.13.10 3.31 4.18.04 7.2.x Yes Dell fw kit: 02.10.38
Microsoft 2008 Windows Server R2 SP1
QLogic QxE826x 9.1.13.10 3.44 4.20.21 7.2.x Yes Dell fw kit: 09.00.03
Microsoft 2008 Windows Server R2 SP1
QLogic QxE826x 9.1.13.10 3.44 4.20.21 7.3.x Yes Dell fw kit: 09.00.03
Microsoft 2012 Windows Server R2
Cisco VIC-12xx 2.4.0.9 2.2(4b) 2.2(4b) 6.7.x Yes
Microsoft 2012 Windows Server R2
Emulex OCx1410x 10.6.114.0 10.6.133.18 10.6.133.18 6.7.x Yes
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.0.247.0 11.0.270.15 11.0.270.15 7.1.x Yes Dell fw kit: 02.00.01
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.0.247.0 11.0.270.4 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.0.247.0 11.0.270.4 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.2.1135.0 11.2.1197.13 11.2.1197.13 7.2.x Yes Dell fw kit: 02.01.01
Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)
95 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FCoE Host Adapter Driver BootCode Firmware SC Version BfS Notes
Microsoft 2012 Windows Server R2
Emulex OCx1410x 11.2.1135.0 11.2.1197.13 11.2.1197.13 7.3.x Yes Dell fw kit: 02.01.01
Microsoft 2012 Windows Server R2
QLogic QxE826x 9.1.12.10 3.28 4.18.04 6.7.x Yes Dell fw kit: 2.10.29
Microsoft 2012 Windows Server R2
QLogic QxE826x 9.1.13.10 3.29 4.18.04 7.1.x Yes Dell fw kit: 02.10.37
Microsoft 2012 Windows Server R2
QLogic QxE826x 9.1.13.10 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38
Microsoft 2012 Windows Server R2
QLogic QxE826x 9.1.13.10 3.31 4.18.04 7.2.x Yes Dell fw kit: 02.10.38
Microsoft 2012 Windows Server R2
QLogic QxE826x 9.1.13.10 3.44 4.20.21 7.2.x Yes Dell fw kit: 09.00.03
Microsoft 2012 Windows Server R2
QLogic QxE826x 9.1.13.10 3.44 4.20.21 7.3.x Yes Dell fw kit: 09.00.03
Microsoft 2012 Windows Server R2
Broadcom 578xx 7.12.1.0 7.12.4 7.12.17 6.7.x Yes
Microsoft 2012 Windows Server R2
Broadcom 578xx 7.12.42.0 7.12.4 7.12.19 7.1.x Yes
Microsoft 2012 Windows Server R2
Broadcom 578xx 7.14.14.0 7.15.0 10.01.00 7.2.x Yes
Microsoft 2012 Windows Server R2
Broadcom 578xx 7.14.14.0 7.15.0 10.01.00 7.3.x Yes
Microsoft 2012 Windows Server R2
Broadcom 578xx 7.14.3.0 7.13.60.0 7.13.60.0 6.7.x Yes Dell fw kit: 08.07.25
Microsoft 2012 Windows Server R2
Broadcom 578xx 7.14.3.0 7.13.60.0 7.13.60.0 7.1.x Yes Dell fw kit: 08.07.25
Microsoft 2012 Windows Server R2
Broadcom 578xx 7.14.3.0 7.13.60.0 7.13.60.0 7.2.x Yes Dell fw kit: 08.07.25
Microsoft 2016 Windows Server
QLogic QL41xxx 8.24.3 - 14.07.05 7.3.x No
Microsoft 2016 Windows Server
QLogic QL41xxx 8.24.3 - 14.07.07 7.1.x No
Microsoft 2016 Windows Server
QLogic QL41xxx 8.24.3 - 14.07.07 7.3.x No
Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)
96 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FCoE Host Adapter Driver BootCode Firmware SC Version BfS Notes
Microsoft 2016 Windows Server
QLogic QL41xxx 8.24.3 - 14.07.07 7.4.x No
Red Hat RHEL 7.x Cisco VIC-12xx 1.6.0.18 2.2(4b) 2.2(4b) 6.7.x Yes
VMWare ESXi 5.5 Cisco VIC-12xx 1.6.0.17a 2.2(4b) 2.2(4b) 6.7.x Yes
VMWare ESXi 5.5 Emulex OCx1410x 10.6.126.0 10.6.133.18 10.6.133.18 6.7.x Yes Dell fw kit: 01.06.01
VMWare ESXi 5.5 Emulex OCx1410x 10.6.126.0 11.0.270.4 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04
VMWare ESXi 5.5 Emulex OCx1410x 11.0.237.0 10.6.133.18 10.6.133.18 7.1.x Yes Dell fw kit: 01.06.01
VMWare ESXi 5.5 Emulex OCx1410x 11.1.145.18 11.0.270.4 11.0.270.2007 6.7.x Yes Dell fw kit: 02.00.04
VMWare ESXi 5.5 Emulex OCx1410x 11.1.145.18 11.0.270.4 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04
VMWare ESXi 5.5 Emulex OCx1410x 11.1.145.18 11.2.1197.13 11.2.1197.13 7.2.x Yes Dell fw kit: 02.01.01
VMWare ESXi 5.5 Emulex OCx1410x 11.1.145.18 11.2.1197.13 11.2.1197.13 7.3.x Yes Dell fw kit: 02.01.01
VMWare ESXi 5.5 QLogic QxE826x 1.1.55.0 3.28 4.18.04 6.7.x Yes Dell fw kit: 2.10.29
VMWare ESXi 5.5 QLogic QxE826x 1.1.55.0 3.29 4.18.04 7.1.x Yes Dell fw kit: 02.10.37
VMWare ESXi 5.5 QLogic QxE826x 1.1.55.0 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38
VMWare ESXi 5.5 QLogic QxE826x 1.1.70.0 3.29 4.18.04 7.1.x Yes Dell fw kit: 02.10.37
VMWare ESXi 5.5 QLogic QxE826x 1.1.70.0 3.31 4.18.04 6.7.x Yes Dell fw kit: 02.10.38
VMWare ESXi 5.5 QLogic QxE826x 1.1.70.0 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38
VMWare ESXi 5.5 QLogic QxE826x 1.1.70.0 3.31 4.18.04 7.2.x Yes Dell fw kit: 02.10.38
VMWare ESXi 5.5 QLogic QxE826x 1.1.70.0 3.44 4.20.21 7.2.x Yes Dell fw kit: 09.00.03
VMWare ESXi 5.5 QLogic QxE826x 1.1.70.0 3.44 4.20.21 7.3.x Yes Dell fw kit: 09.00.03
VMWare ESXi 5.5 Broadcom 578xx 1.712.30.v55.2 7.12.4 7.12.17 6.7.x Yes
VMWare ESXi 5.5 Broadcom 578xx 1.712.70.v55.5 7.12.4 08.07.25 6.7.x Yes
VMWare ESXi 5.5 Broadcom 578xx 1.712.70.v55.5 7.12.4 08.07.25 7.1.x Yes
VMWare ESXi 5.5 Broadcom 578xx 1.712.70.v55.5 7.12.4 08.07.25 7.2.x Yes
VMWare ESXi 5.5 Broadcom 578xx 1.712.70.v55.5 7.12.5 7.12.19 7.1.x Yes
VMWare ESXi 5.5 Broadcom 578xx 1.713.10.v55.4 7.15.0 10.01.00 7.2.x Yes Dell fw kit: 10.01.00
VMWare ESXi 5.5 Broadcom 578xx 1.713.10.v55.4 7.15.0 10.01.00 7.3.x Yes Dell fw kit: 10.01.00
VMWare ESXi 6.0 Emulex OCx1410x 10.6.126.0 10.6.133.18 10.6.133.18 7.1.x Yes Dell fw kit: 01.06.01
VMWare ESXi 6.0 Emulex OCx1410x 11.1.145.18 11.0.270.4 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.0 Emulex OCx1410x 11.1.145.18 11.0.270.4 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04
VMWare ESXi 6.0 Emulex OCx1410x 11.1.145.18 11.0.270.4 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04
Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)
97 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Operating System FCoE Host Adapter Driver BootCode Firmware SC Version BfS Notes
VMWare ESXi 6.0 Emulex OCx1410x 11.2.156.20 11.2.1197.13 11.2.1197.13 7.2.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.0 Emulex OCx1410x 11.4.142.11 11.2.1197.13 11.2.1197.13 7.3.x Yes Dell fw kit: 02.01.01
VMWare ESXi 6.0 QLogic QxE826x 2.1.20.0 3.28 4.18.04 6.7.x Yes Dell fw kit: 2.10.29
VMWare ESXi 6.0 QLogic QxE826x 2.1.24.0 3.29 4.18.04 7.1.x Yes Dell fw kit: 02.10.37
VMWare ESXi 6.0 QLogic QxE826x 2.1.24.0 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38
VMWare ESXi 6.0 QLogic QxE826x 2.1.24.0 3.31 4.18.04 7.2.x Yes Dell fw kit: 02.10.38
VMWare ESXi 6.0 QLogic QxE826x 2.1.43.0 3.31 4.18.04 6.7.x Yes Dell fw kit: 02.10.38
VMWare ESXi 6.0 QLogic QxE826x 2.1.43.0 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38
VMWare ESXi 6.0 QLogic QxE826x 2.1.43.0 3.31 4.18.04 7.2.x Yes Dell fw kit: 02.10.38
VMWare ESXi 6.0 QLogic QxE826x 2.1.50.0 3.44 4.20.21 7.2.x Yes Dell fw kit: 09.00.03
VMWare ESXi 6.0 QLogic QxE826x 2.1.57.0 3.44 4.20.21 7.3.x Yes Dell fw kit: 09.00.03
VMWare ESXi 6.0 Broadcom 578xx 1.712.10.v55.2 - N/A 7.1.x No Dell fw kit: 08.07.25
VMWare ESXi 6.0 Broadcom 578xx 1.712.10.v55.2 - N/A 7.2.x No Dell fw kit: 08.07.25
VMWare ESXi 6.0 Broadcom 578xx 1.712.30.v55.2 - 08.07.25 7.1.x No
VMWare ESXi 6.0 Broadcom 578xx 1.712.30.v55.2 - 08.07.25 7.2.x No
VMWare ESXi 6.0 Broadcom 578xx 1.712.30.v55.2 - N/A 6.7.x No Dell fw kit: 7.12.17
VMWare ESXi 6.0 Broadcom 578xx 1.712.30.v55.2 - 7.12.4 6.7.x No Dell fw kit: 7.12.17
VMWare ESXi 6.0 Broadcom 578xx 1.712.30.v55.2 - 7.12.4 7.1.x No Dell fw kit: 7.12.19
VMWare ESXi 6.0 Broadcom 578xx 1.712.70.v55.5 - N/A 6.7.x No Dell fw kit: 08.07.25
VMWare ESXi 6.0 Broadcom 578xx 1.712.70.v55.5 - N/A 7.1.x No Dell fw kit: 08.07.25
VMWare ESXi 6.0 Broadcom 578xx 1.712.70.v55.5 - N/A 7.2.x No Dell fw kit: 08.07.25
VMWare ESXi 6.0 Broadcom 578xx 1.713.10.v60.4 - 08.07.25 7.1.x No
VMWare ESXi 6.0 Broadcom 578xx 1.713.10.v60.4 - 08.07.25 7.2.x No
VMWare ESXi 6.0 Broadcom 578xx 1.713.30.v60.3 - 10.01.00 7.2.x No Dell fw kit: 10.01.00
VMWare ESXi 6.0 Broadcom 578xx 1.713.30.v60.3 - 10.01.00 7.3.x No Dell fw kit: 10.01.00
VMWare ESXi 6.0 Broadcom 578xx 1.713.30.v60.6 - 10.01.00 7.3.x No Dell fw kit: 10.01.00
VMWare ESXi 6.5 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.3.x No
VMWare ESXi 6.5 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.4.x No
VMWare ESXi 6.7 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.3.x No
VMWare ESXi 6.7 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.4.x No
VMWare ESXi 6.7 QLogic QL41xxx 1.2.24.6 - 14.07.50 7.3.x No
Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)
98 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
4.5.2 Software FCoE initiators (SC and SCv Series) Software FCoE initiators may be provided by the host OS vendor and can be used with any industry-standards-based network interface controller
(NIC) that supports software-based FCoE. The following table provides guidance on which software FCoE initiators have been tested with each
platform and the support level for advanced features, such as boot from SAN.
If boot from SAN functionality is desired, it is advised that the design include one of the Adapters listed ensure the indicated support level. Always
verify OS support by SC Series product.
Operating System SC Version BfS Notes
VMWare ESXi 5.5 6.7.x No
VMWare ESXi 5.5 7.1.x No
VMWare ESXi 5.5 7.2.x No
VMWare ESXi 5.5 7.3.x No
VMWare ESXi 6.0 6.7.x No
VMWare ESXi 6.0 7.1.x No
VMWare ESXi 6.0 7.2.x No
VMWare ESXi 6.0 7.3.x No
VMWare ESXi 6.5 7.3.x No
VMWare ESXi 6.5 7.4.x No
VMWare ESXi 6.7 7.3.x No
VMWare ESXi 6.7 7.4.x No
Other support matrices
99 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
5 Other support matrices
5.1 Cisco UCS support In cooperation with Cisco, Dell is now certified for certain UCS configurations. UCS
certifications can be found in the Cisco UCS Interoperability Matrix.
5.2 Storage virtualization appliances Dell does not directly test or validate third-party storage virtualization appliances in
front of Dell storage products. Dell does work with various third-party vendors of such
appliances to ensure that our arrays have been validated with these vendor’s devices
and to ensure that our storage products are listed in each vendor’s respective
certification matrices. Please reference the vendor specific sites to verify product
interoperability support.
5.3 KMS solutions SC Series supports 3rd party external key management with Gemalto and Thales.
5.4 Data Protection SC Series snapshot integration support with 3rd party data protection solutions.
Vendor KMS solution KMS version SCOS version
Gemalto SafeNet KeySecure k150v 8.0.x 6.5.x, 6.6.x, 6.7.x, 7.1.x
8.5.0, 8.7.x, 8.10.x 6.5.x, 6.6.x, 6.7.x, 7.1.x,
7.3.x
SafeNet KeySecure k250 6.6.x 6.5.x, 6.6.x, 6.7.x, 7.1.x
8.1.x, 8.7.x, 8.10.x 6.5.x, 6.6.x, 6.7.x, 7.1.x,
7.3.x
SafeNet KeySecure k460 6.6.x 6.5.x, 6.6.x, 6.7.x, 7.1.x
8.7.x, 8.10.x 6.5.x, 6.6.x, 6.7.x, 7.1.x,
7.3.x
Thales EMS 200 4.0.2 6.5.x, 6.6.x, 6.7.x, 7.1.x,
7.2.x, 7.3.x
Vendor Software Version Plug-in Version SCOS version
CommVault Simpana 11 SP13 CVSE 3.2 7.3.x, 7.4.x
Veeam 9.5 u4A, u4B 1.0.210 7.4.x
Required Adapter and Server OS Settings
100 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A Required Adapter and Server OS Settings
Server host bus adapters and converged network adapters (hereafter called adapters) require specific
configuration settings in order to maintain IO during Storage Center controller failovers and network/fabric
path failovers. Some of these settings are identical for all supported operating systems and others vary by
operating system. The information below identifies adapter settings that are identical for all supported
operating systems. If the adapter is not listed below, default settings are acceptable.
A.1 Adapter Settings
A.1.1 Cisco Fibre Channel Adapters
Field Setting
Flogi Retries 60
Plogi Retries 60
A.1.2 Emulex Fibre Channel Adapters
Field Settings
Topology
LPe16xxx and earlier: 1 (point to point)
VMware ESXi: Set topology to 2 for
Auto Topology (point to point first)
LPe31xxx and later: N/A, value does
not exist
NodeTimeOut Node Time Out field,
lpfc_devloss_tmo (formerly nodev_tmo)
60
A.1.3 QLogic Fibre Channel Adapters (and re-branded adapters based
on QLogic)
Field Settings
Connection option QLe25xx and earlier: 1 (point-to-point)
QLe26xx and later: Default
Login retry count 60
Required Adapter and Server OS Settings
101 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Field Settings
Port down retry count 60
Link down timeout 30
Required Adapter and Server OS Settings
102 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A.2 Server OS Settings
A.2.1 Windows Server 2008r2
A.2.1.1 Recommended updates and hotfixes for Windows Server 2008r2
See the Microsoft Update Catalog at https://www.catalog.update.microsoft.com/Home.aspx
to locate specific KB downloads.
KB number Title
KB3125574 Convenience rollup update for Windows 7 SP1 and Windows Server 2008 R2 SP1 (May 2016) msdsm.sys version 6.1.7601.23403 (3/25/16) mpio.sys version 6.1.7601.23403 (3/25/16) msiscsi.sys version 6.1.7601.23403 (3/25/16) storport.sys version 6.1.7601.23403 (3/25/16)
A.2.1.2 Recommended MPIO registry settings for Windows Server 2008r2
The recommend registry settings listed in this section can be applied using the registry
editor (regedit.exe) or through PowerShell. The registry editor can be used on all versions of
Windows Server Desktop (Windows Server with a GUI).
MPIO Registry Settings: HKLM\SYSTEM\CurrentControlSet\Services\mpio\Parameters
Setting name Description Default value
Recommended value
PDORemovePeriod This setting controls the number of seconds that the multipath pseudo-LUN remains in system memory, even after losing all paths to the device. When this timer value is exceeded, pending I/O operations will be failed, and the failure is exposed to the application rather than attempting to continue to recover active paths. The maximum time allowed is MAXULONG (49,000 seconds).
20 120
PathRecoveryInterval This represents the period after which PathRecovery is attempted. This setting is only used if it is not set to 0 and UseCustomPathRecoveryInterval is set to 1.
40 25
UseCustomPathRecoveryInterval If this key exists and is set to 1, it allows the use of PathRecoveryInterval.
0 1
Required Adapter and Server OS Settings
103 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
MPIO Registry Settings: HKLM\SYSTEM\CurrentControlSet\Services\mpio\Parameters
Setting name Description Default value
Recommended value
PathVerifyEnabled This flag enables path verification by MPIO on all paths every N seconds (where N depends on the value set in PathVerificationPeriod).
This Boolean function must be filled with either 0 (disable) or 1 (enable). By default, it is disabled.
0 1
PathVerificationPeriod This setting is used to indicate the number of seconds with which MPIO has been requested to perform path verification. This field is only honored if PathVerifyEnabled is TRUE. This timer is specified in seconds. The default is 30 seconds. The maximum allowed is MAXULONG.
30 no change
RetryCount This setting specifies the number of times a failed I/O if the DSM determines that a failing request must be retried. This is invoked when DsmInterpretError() returns Retry = TRUE. The default setting is 3.
3 no change (FC or iSCSI systems)
15 (front-end SAS systems only)
RetryInterval This setting specifies the interval of time (in seconds) after which a failed request is retried (after the DSM has decided so, and assuming that the I/O has been retried a fewer number of times than RetryCount). This value is specified in seconds. The default is 1 second.
1 no change
DiskPathCheckEnabled If the DiskPathCheckEnabled key is set to a nonzero value, the MPIO component creates a path recovery worker.
- 1
DiskPathCheckInterval If the DiskPathCheckInterval key is set to 0, or if the key does not exist, the MPIO component uses a default time interval. The default time interval is half of the time that is set in the PDORemovePeriod parameter.
- 25
Required Adapter and Server OS Settings
104 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A.2.1.3 Recommended Disk registry settings for Windows Server 2008r2
Disk registry settings location: HKLM\SYSTEM\CurrentControlSet\Services\disk
Setting name
Description Default value
Recommended value
TimeoutValue Disk time-out is a registry setting that defines the time that Windows will wait for a hard disk to respond to a command. Installing host bus adapters (HBA) or other storage controllers can cause this key to be created and configured.
60 no change
A.2.1.4 iSCSI initiator settings for Windows Server 2008r2
These settings apply to single-path and MPIO configurations that use iSCSI to connect to
SC Series storage.
Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}\<Instance Number>\Parameters
Setting name Description Default value
Recommended value
MaxRequestHoldTime This is the maximum number of seconds that requests are queued if connection to the target is lost and the connection is being retried. After this hold period, requests will be failed with error no device and device (disk) will be removed from the system.
60 90
LinkDownTime This value determines how long requests will be held in the device queue and retried if the connection to the target is lost. If MPIO is installed this value is used. If MPIO is not installed MaxRequestHoldTime is used instead.
15 35
TCPConnectTime Timeout given to TCP when a Connect request is sent.
15 no change
TCPDisconnectTime Timeout given to TCP when a Disconnect request is sent.
15 no change
WMIRequestTimeout Timeout value set for WMI requests such as LoginToTarget or LogoutFromTarget, SendTargets.
30 no change
Required Adapter and Server OS Settings
105 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}\<Instance Number>\Parameters
Setting name Description Default value
Recommended value
DelayBetweenReconnect If a connection is dropped while it is in FullFeature phase, the driver will attempt to re-login. This parameter sets the delay between each re-login attempts.
5 no change
MaxConnectionRetries Maximum number of times a lost TCP connection will be retried.
4294967295 (indefinitely)
no change
MaxPendingRequests This setting controls the maximum number of outstanding requests allowed by the initiator. At most this many requests will be sent to the target before receiving response for any of the requests.
255 no change
EnableNOPOut If set to 1, the initiator will send NOP OUT PDUs to target if there is no activity for 2 minutes.
0 1
MaxTransferLength This is maximum data size of an I/O request.
262144 (256KB)
no change
MaxBurstLength This is the negotiated Max Burst Length.
262144 (256KB)
no change
FirstBurstLength This is the negotiated First Burst Length.
65536 (64KB)
no change
MaxRecvDataSegmentLength This is the negotiated MaxRecvDataSegmentLength.
65536 (64KB)
no change
IPSecConfigTimeout This timeout value is used when the driver calls the discovery service to configure\release IPsec for an iSCSI connection.
60 no change
InitialR2T If set to Non-Zero value, initiator will request InitialR2T (InitialR2T=Yes). Else initiator will not request InitialR2T (InitialR2T=No).
0 no change
ImmediateData If set to Non-Zero value, initiator will request ImmediateData (ImmediateData=Yes). Else initiator will not request ImmediateData (ImmediateData=No).
1 (Yes) no change
PortalRetryCount This value is used to determine how many times a connect request to a target portal should be retried if the portal is down.
5 no change
Required Adapter and Server OS Settings
106 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}\<Instance Number>\Parameters
Setting name Description Default value
Recommended value
NetworkReadyRetryCount This value is used to determine how many times initiator should retry getting the IP address of NIC corresponding to the PortNumber specified in the login request.
10 no change
ErrorRecoveryLevel Error recovery level that the initiator will request.
2 no change
Enable RFC1323 Timestamps
Enable RFC1323 timestamps (TCP High Performance Extensions) to prevent sequence
number wrap under high load, known as Prevention Against Wrapped Sequence (PAWS).
High-load iSCSI connections are prone to this issue, particularly at 10GbE or higher. Run
this command at elevated CMD prompt to add a registry key (set to value of 2 by default;
this is the desired value):
netsh int tcp set global timestamps=enabled
The registry setting can be checked and confirmed as shown below:
• HKLM\SYSTEM\CurrentControlSet\Services\TCPIP\Parameters\Tcp1323Opts
• Values: 0 = Timestamps + windows scaling disabled
1 = Windows Scaling Enabled
2 = Timestamps enabled ✓
3 = both enabled
Disable Nagle’s Algorithm
To disable delayed ACK and Nagle’s algorithm, create the following DWORD 32-bit entries
for each SAN interface subkey in the Windows Server registry:
HKLM\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters\Interfaces\<
SAN interface GUID>
Create or verify these DWORD 32-bit entries. Set them to a value of 1 (disabled)
TcpAckFrequency
TcpNoDelay
Note: A reboot is required for any registry changes to take effect. Alternatively, unloading and reloading the initiator driver will also cause the change to take effect. In the Device Manager GUI, under Storage controllers, right-click Microsoft iSCSI Initiator, and select Disable to unload the driver. Then, select Enable to reload the driver.
Required Adapter and Server OS Settings
107 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A.2.2 Windows Server 2012 and Later
A.2.2.1 Recommended updates and hotfixes for Windows Server 2012 and Later
See the Microsoft Update Catalog at https://www.catalog.update.microsoft.com/Home.aspx
to locate specific KB downloads.
Windows Version
KB number Title
2012 3018489 “No host bus adapter is present” error when querying SAS cable issues in Windows Server 2012 R2 or Windows Server 2012 storport.sys version 6.2.9200.17188 (11/19/14)
3046101 Server may freeze during startup when ALUA-capable storage is used in Windows Server 2012 R2 or Windows Server 2012 mpio.sys version 6.2.9200.17071 (8/5/14) msdsm.sys version 6.2.9200.17362 (5/6/15)
3102997 Data is corrupted after iSCSI sessions or paths recover in Windows Server 2012 R2 or Windows Server 2012 msiscsi.sys version 6.2.9200.21687 (11/8/15)
2012R2 2016 2019
N/A Microsoft publishes updates for Windows Server
2012 R2, Windows Server 2016, and Windows
Server 2019 cumulatively. Any updates for storage-
related files are included in the monthly cumulative
updates. Apply the latest monthly cumulative update
from Microsoft to ensure that the storage-related
files msdsm.sys, mpio.sys, msiscsi.sys and
storport.sys stay current.
A.2.2.2 Recommended MPIO registry settings for Windows Server 2012 and Later
The recommend registry settings listed in this section can be applied using the registry
editor (regedit.exe) or through PowerShell. The registry editor can be used on all versions of
Windows Server Desktop (Windows Server with a GUI).
Required Adapter and Server OS Settings
108 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
MPIO Registry Settings: HKLM\SYSTEM\CurrentControlSet\Services\mpio\Parameters
Setting name Description Default value
Recommended value
PDORemovePeriod This setting controls the number of seconds that the multipath pseudo-LUN remains in system memory, even after losing all paths to the device. When this timer value is exceeded, pending I/O operations will be failed, and the failure is exposed to the application rather than attempting to continue to recover active paths. The maximum time allowed is MAXULONG (49,000 seconds).
20 120
PathRecoveryInterval This represents the period after which PathRecovery is attempted. This setting is only used if it is not set to 0 and UseCustomPathRecoveryInterval is set to 1.
40 25
UseCustomPathRecoveryInterval If this key exists and is set to 1, it allows the use of PathRecoveryInterval.
0 1
PathVerifyEnabled This flag enables path verification by MPIO on all paths every N seconds (where N depends on the value set in PathVerificationPeriod).
This Boolean function must be filled with either 0 (disable) or 1 (enable). By default, it is disabled.
0 1
PathVerificationPeriod This setting is used to indicate the number of seconds with which MPIO has been requested to perform path verification. This field is only honored if PathVerifyEnabled is TRUE. This timer is specified in seconds. The default is 30 seconds. The maximum allowed is MAXULONG.
30 no change
Required Adapter and Server OS Settings
109 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
MPIO Registry Settings: HKLM\SYSTEM\CurrentControlSet\Services\mpio\Parameters
Setting name Description Default value
Recommended value
RetryCount This setting specifies the number of times a failed I/O if the DSM determines that a failing request must be retried. This is invoked when DsmInterpretError() returns Retry = TRUE. The default setting is 3.
3 no change (FC or iSCSI systems)
15 (front-end SAS systems only)
RetryInterval This setting specifies the interval of time (in seconds) after which a failed request is retried (after the DSM has decided so, and assuming that the I/O has been retried a fewer number of times than RetryCount). This value is specified in seconds. The default is 1 second.
1 no change
DiskPathCheckDisabled If the DiskPathCheckDisabled key is set to zero, the MPIO component creates a path recovery worker.
0 no change
DiskPathCheckInterval If the DiskPathCheckInterval key is set to 0, or if the key does not exist, the MPIO component uses a default time interval. The default time interval is half of the time that is set in the PDORemovePeriod parameter.
10 25
Required Adapter and Server OS Settings
110 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A.2.2.3 Recommended Disk registry settings for Windows Server 2012 and Later
Recommended disk registry settings location: HKLM\SYSTEM\CurrentControlSet\Services\disk
Setting name
Description Default value
Recommended value
TimeoutValue Disk time-out is a registry setting that defines the time that Windows will wait for a hard disk to respond to a command. Installing host bus adapters (HBA) or other storage controllers can cause this key to be created and configured.
60 no change
A.2.2.4 iSCSI initiator settings for Windows Server 2012 and Later
These settings apply to single-path and MPIO configurations that use iSCSI to connect to
SC Series storage.
Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}\<Instance Number>\Parameters
Setting name Description Default value
Recommended value
MaxRequestHoldTime This is the maximum number of seconds that requests are queued if connection to the target is lost and the connection is being retried. After this hold period, requests will be failed with error no device and device (disk) will be removed from the system.
60 90
LinkDownTime This value determines how long requests will be held in the device queue and retried if the connection to the target is lost. If MPIO is installed this value is used. If MPIO is not installed MaxRequestHoldTime is used instead.
15 35
TCPConnectTime Timeout given to TCP when a Connect request is sent.
15 no change
TCPDisconnectTime Timeout given to TCP when a Disconnect request is sent.
15 no change
WMIRequestTimeout Timeout value set for WMI requests such as LoginToTarget or LogoutFromTarget, SendTargets.
30 no change
Required Adapter and Server OS Settings
111 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}\<Instance Number>\Parameters
Setting name Description Default value
Recommended value
DelayBetweenReconnect If a connection is dropped while it is in FullFeature phase, the driver will attempt to re-login. This parameter sets the delay between each re-login attempts.
5 no change
MaxConnectionRetries Maximum number of times a lost TCP connection will be retried.
4294967295 (indefinitely)
no change
MaxPendingRequests This setting controls the maximum number of outstanding requests allowed by the initiator. At most this many requests will be sent to the target before receiving response for any of the requests.
255 no change
EnableNOPOut If set to 1, the initiator will send NOP OUT PDUs to target if there is no activity for 2 minutes.
0 1
MaxTransferLength This is maximum data size of an I/O request.
262144 (256KB)
no change
MaxBurstLength This is the negotiated Max Burst Length. 262144 (256KB)
no change
FirstBurstLength This is the negotiated First Burst Length. 65536 (64KB)
no change
MaxRecvDataSegmentLength This is the negotiated MaxRecvDataSegmentLength.
65536 (64KB)
no change
IPSecConfigTimeout This timeout value is used when the driver calls the discovery service to configure\release IPsec for an iSCSI connection.
60 no change
InitialR2T If set to Non-Zero value, initiator will request InitialR2T (InitialR2T=Yes). Else initiator will not request InitialR2T (InitialR2T=No).
0 no change
ImmediateData If set to Non-Zero value, initiator will request ImmediateData (ImmediateData=Yes). Else initiator will not request ImmediateData (ImmediateData=No).
1 (Yes) no change
PortalRetryCount This value is used to determine how many times a connect request to a target portal should be retried if the portal is down.
5 no change
NetworkReadyRetryCount This value is used to determine how many times initiator should retry getting the IP address of NIC corresponding to the PortNumber specified in the login request.
10 no change
Required Adapter and Server OS Settings
112 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}\<Instance Number>\Parameters
Setting name Description Default value
Recommended value
ErrorRecoveryLevel Error recovery level that the initiator will request.
2 no change
Enable RFC1323 Timestamps
Enable RFC1323 timestamps (TCP High Performance Extensions) to prevent sequence
number wrap under high load, known as Prevention Against Wrapped Sequence (PAWS).
High-load iSCSI connections are prone to this issue, particularly at 10GbE or higher. Run
this command at elevated CMD prompt to add a registry key (set to value of 2 by default;
this is the desired value):
netsh int tcp set global timestamps=enabled
The registry setting can be checked and confirmed as shown below:
• HKLM\SYSTEM\CurrentControlSet\Services\TCPIP\Parameters\Tcp1323Opts
• Values: 0 = Timestamps + windows scaling disabled
1 = Windows Scaling Enabled
2 = Timestamps enabled ✓
3 = both enabled
Disable Nagle’s Algorithm
To disable delayed ACK and Nagle’s algorithm, create the following DWORD 32-bit entries
for each SAN interface subkey in the Windows Server registry:
HKLM\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters\Interfaces\<
SAN interface GUID>
Create or verify these DWORD 32-bit entries. Set them to a value of 1 (disabled)
TcpAckFrequency
TcpNoDelay
Disable NIC Interrupt Modulation:
1. Click Adapter Settings.
1. Right-click the adapter and select Properties.
2. Under the Networking tab, click Configure.
3. Under the Advanced tab, select Interrupt Moderation and choose Disabled.
Note: A reboot is required for any registry changes to take effect. Alternatively, unloading and reloading the initiator driver will also cause the change to take effect. In the Device Manager GUI, under Storage controllers, right-click Microsoft iSCSI Initiator, and select Disable to unload the driver. Then, select Enable to reload the driver.
Required Adapter and Server OS Settings
113 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A.2.3 Linux (Red Hat, SuSE, Oracle, Ubuntu)
A.2.3.1 FC PortDown timeout
The HBA PortDown timeout parameter dictates how long a Linux system waits before
destroying a connection after being losing its connectivity with the port. The PortDown
timeout is generally set to 60 seconds for the SC Series storage system.
To configure the PortDown timeout in the HBA driver module, add or append the following
options to the appropriate HBA driver module configuration file and reload the driver module.
A. For Qlogic, add in /etc/modprobe.d/qla2xxx.conf
options qla2xxx qlport_down_retry=60
Reload the module
# modprobe –r qla2xxx
# modprobe qla2xxx
B. For Emulex, add in /etc/modprobe.d/lpfc.conf
options lpfc lpfc_devloss_tmo=60
Reload the module
# modprobe –r lpfc
# modprobe lpfc
A.2.3.2 Verifying parameters
To verify that the configuration changes have taken effect, examine the driver module
parameter values in their respective files.
A. For QLogic:
# cat /sys/module/qla2xxx/parameters/qlport_down_retry
B. For Emulex:
# cat /sys/module/lpfc/parameters/lpfc_devloss_tmo
# cat /sys/class/scsi_host/hostX/lpfc_devloss_tmo #where X is
the HBA no.
A.2.3.3 FC/iSCSI volume multipath configuration
A basic template can be copied from /usr/share/doc/device-mapper-multipath-
<version>/multipath.conf to /etc/multipath.conf as a starting point. Any
settings that are not defined explicitly in the file would assume the default values. The full list
of these settings can be obtained using the following command. Specific SC Series storage
system settings can be found by searching for COMPELNT from the output.
# multipathd –k"show config"
Required Adapter and Server OS Settings
114 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
To avoid confusion and as a best practice, it is recommended to always explicitly define the
SC Series storage in /etc/multipath.conf. The following example show multipath
configuration for SC Series volumes on RHEL 6 and newer. Please note that these
configurations apply only in FC and iSCSI implementations. The SAS multipath
configuration is discussed in section A.2.3.5 and should be used instead in SAS
implementations.
defaults {
user_friendly_names yes
find_multipaths yes
}
devices {
device {
vendor "COMPELNT"
product "Compellent Vol"
path_grouping_policy multibus
path_selector "service-time 0" # See note below
path_checker tur
features "0"
hardware_handler "0"
prio const
failback immediate
rr_weight uniform
no_path_retry queue
}
}
Note: "round-robin 0" is the default for RHEL 6 and older. "service-time 0" is the
default for RHEL 7 and newer. Both are acceptable values for SC Series FC/iSCSI volumes.
Once the configuration file is in place, reload multipathd with the updated configuration.
# multipath -r
# multipath –ll
A.2.3.4 iSCSI timeout for multipath environments
The pre-configured iSCSI settings, defined in /etc/iscsi/iscsi.conf, work with SC
Series storage system when the Linux system is also configured to use dm-multipath. It
is a best practice to use dm-multipath for path redundancy and failover. It is important to
note the following timeout settings because they directly affect the storage availability and
failure recovery for a SAN storage system. When a SC Series storage system controller
fails, services and volumes fail over to the surviving controller and this failover might take up
to 60 seconds. Therefore ensure the iSCSI timeout settings are sufficient to accommodate
this kind of events. These pre-configured timeout settings, listed below, work well with SC
Series storage systems.
• node.conn[0].timeo.noop_out_interval = 5
• node.conn[0].timeo.noop_out_timeout = 5
Required Adapter and Server OS Settings
115 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
• node.session.timeo.replacement_timeout = 120
A.2.3.5 SAS volume multipath configuration
SAS connectivity to a Linux system requires specific configuration schema in the
/etc/multipath.conf file. Add the following device section to /etc/multipath.conf
used exclusively for SAS-connected Linux systems. The following example define the
configuration parameters for all devices identified by vendor="COMPELNT" and
product="Compellent Vol".
devices {
device {
vendor COMPELNT
product "Compellent Vol"
path_checker tur
prio alua
path_selector "service-time 0"
path_grouping_policy group_by_prio
no_path_retry 24
hardware_handler "1 alua"
failback immediate
rr_weight priorities
}
}
A properly configured SAS volume will return the following multipath -ll output. This SC
Series volume is discovered as a multipath ALUA-capable volume, where each path is
capable of I/O. The path represented by prio=50 (active/optimized path) is used for all
active I/O requests. The path represented by prio=1 (standby path) is a highly available,
redundant path and is used when the active/optimized path becomes unavailable.
# multipath -ll
Compelnt_0016 (36000d31000feb3000000000000000016) dm-3
COMPELNT,Compellent Vol
size=100G features='1 queue_if_no_path' hwhandler='1 alua' wp=rw
|-+- policy='service-time 0' prio=50 status=active
| `- 1:0:0:1 sdb 8:16 active ready running
`-+- policy='service-time 0' prio=1 status=enabled
`- 1:0:1:1 sdc 8:32 active ready running
Compelnt_001a (36000d31000feb300000000000000001a) dm-4
COMPELNT,Compellent Vol
size=100G features='1 queue_if_no_path' hwhandler='1 alua' wp=rw
|-+- policy='service-time 0' prio=50 status=active
| `- 1:0:1:2 sdd 8:48 active ready running
`-+- policy='service-time 0' prio=1 status=enabled
`- 1:0:2:2 sde 8:64 active ready running
Required Adapter and Server OS Settings
116 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A.2.4 VMware
A.2.4.1 SAS HBA settings
For SC Series arrays that have SAS front-end ports, use the following recommendations.
For the mpt3sas, use all the default driver module settings.
For the lsi_msgpt3, change the following module parameter setting as recommended by the
Dell KB article Driver Compatibility with Front End SAS Connectivity.
esxcli system module parameters set -p
issue_scsi_cmd_to_bringup_drive=0 -m lsi_msgpt3
A.2.4.2 Setting round robin to be the default path selection policy
The round robin path selection policy (PSP) should be set to the default using the following
command. After creating the claim rule and rebooting, all SC Series volumes and protocol
endpoints will acquire this policy.
esxcli storage nmp satp rule add -s VMW_SATP_ALUA -V COMPELNT -P
VMW_PSP_RR -o disable_action_OnRetryErrors -e "Dell EMC SC Series
Claim Rule"
A.2.4.3 Fibre Channel adapter driver settings by vendor
Fibre Channel: QLogic driver module settings for queue depth and controller failover
esxcli system module parameters set -m qlnativefc -p
"ql2xmaxqdepth=255 ql2xloginretrycount=60 qlport_down_retry=60"
Fibre Channel: Emulex driver module settings for queue depth and controller failover
esxcli system module parameters set -m lpfc820 -p
"lpfc_devloss_tmo=60 lpfc_lun_queue_depth=254"
A.2.4.4 Setting ARPRedirect on specified hardware iSCSI adapter
esxcli iscsi physicalnetworkportal param set --option ArpRedirect –
v=1 -A vmhbaXX
A.2.4.5 Set software based iSCSI login timeout
esxcli iscsi adapter param set –A=vmhbaXX –k=LoginTimeout –v=5
A.2.4.6 Set software based iSCSI Queue Depth
esxcli system module parameters set -m iscsi_vmk -p
iscsivmk_LunQDepth=255
A.2.4.7 Setting ALUA mode for FCoE based volumes
esxcli storage nmp satp rule add -R fcoe -s VMW_SATP_ALUA
Required Adapter and Server OS Settings
117 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A.2.5 Oracle Solaris
A.2.5.1 QLogic settings set in /kernel/drv/qlc.conf
login-retry-count=60;
port-down-retry-count=60;
link-down-timeout=30;
connection_options=1;
A.2.5.2 Emulex settings in /kernel/drv/emlxs.conf
topology=2;
A.2.5.3 Solaris 10 & 11 Timeouts (reboot required)
In /kernel/drv/fcp.conf
fcp_offline_delay=60;
In /kernel/drv/fp.conf
fp_offline_ticker=90;
Required Adapter and Server OS Settings
118 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A.2.6 IBM AIX
A.2.6.1 Dell EMC MPIO ODM Path Control Module
The Dell EMC MPIO ODM Path Control Module must be installed on the AIX server for proper operation with the Dell Compellent Storage Center.
A.2.6.2 Dynamic Tracking
Dynamic tracking must be enabled on fibre channel adapters. Dynamic tracking is enabled by default
on all systems Running AIX 7.1 and higher. Dynamic tracking is also enabled on all VFC adapters in
LPARs and cannot be disabled.
1. Determine fibre channel adapter names
a. lsdev | grep fscsi
2. Determine if Dynamic Tracking is enabled
a. lsattr -El fscsi[n] | grep dyntr
3. Enabled Dynamic Tracking for all fibre channel adapters where it’s not
a. chdev -l fscsi[n] -a dyntrk=yes –P
4. Set fast_fail when Dynamic Tracking is enabled (-P applies after reboot)
a. chdev -l fscsi0 -a fc_err_recov=fast_fail –P
Required Adapter and Server OS Settings
119 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A.2.7 Citrix Hypervisor (XenServer)
A.2.7.1 XenServer Versions 5.x to 6.2
For Citrix XenServer versions 5.x through 6.2, to ensure that XenServer volumes will persist
after a Storage Center controller failover, apply the following timeout values. These settings
are located in the mpathHBA •le located in the /opt/xensource/sm/ directory. When fnished,
save the file and reboot the server.
Citrix XenServer HBA Settings for Versions 5.x to 6.2
Field Setting
DEFAULT_TIMEOUT 60
MPATH_TIMEOUT 60
A.2.7.2 XenServer Version 6.5 and Later
For Citrix XenServer version 6.5 and later, the multipath configuration file has been
relocated. To ensure that XenServer volumes will persist after a Storage Center controller
failover, apply the following timeout value. This setting is located in the defaults section of
the multipath.conf configuration file located in the /etc directory. When •nished, save the
•le and reboot the server.
The following code provides an example:
defaults {
user_friendly_names no
replace_wwid_whitespace yes
dev_loss_tmo 30
}
NOTE: The default value for the dev_loss_tmo timeout setting is 30. However, Dell EMC recommends that the default is set to 60.
Citrix XenServer HBA Settings for Version 6.5 and Later
Field Setting
dev_loss_tmo 60
Required Adapter and Server OS Settings
120 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
A.2.8 HP-UX 11i
Configure the HP-UX environment to match the following configurations based on the
version of HP-UX running on the server.
A.2.8.1 V 2 and Earlier
HP-UX version 11.21 and earlier does not require changes. However, a Cisco fabric with
Persistent FCID enabled is required to survive a Dell Storage Center failover or port
rebalance.
A.2.8.2 V 3
HP-UX version 11.31 works best with Storage Center when Agile Addressing is enabled.
With HP-UX version 11.31, Storage Center requires that Agile Addressing be enabled for
proper failover of Storage Center storage systems.
SC and SCv Fibre Channel Zoning
121 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
B SC and SCv Fibre Channel Zoning
Front-end zoning on a Fibre Channel fabric can be configured using either World
Wide Name (WWN) zoning or Brocade Peer Zoning.
Storage Center zones when using WWN zoning:
• Include all Storage Center virtual WWPNs in a single zone.
• Include all Storage Center physical WWPNs in a single zone.
Server zones when using WWN zoning:
• For each server HBA port, create a zone that includes the HBA port WWPN and multiple
Storage Center virtual WWPNs in the same FC fabric.
Storage Center zone when using Peer Zoning:
• Include all Storage Center physical WWPNs in a single standard WWN zone.
Server zone when using Peer Zoning:
• Include all Storage Center virtual WWPNs as the Principal Members of the Peer Zone.
• Include all server HBA port WWPNs as the Peer Members of the Peer Zone.
NOTE: Brocade FOS 8.1 or greater is required to include aliases in Peer Zones.
SC to SC replication zoning on a Fibre Channel fabric can be configured with WWN
zoning.
Storage Center replication zones when using WWN zoning:
• Include all designated physical WWPNs from system A and system B in a single zone.
• Include all designated physical WWPNs of system A and the virtual WWPNs of system B
in a single zone.
• Include all designated physical WWPNs of system B and the virtual WWPNs of system A
in a single.
NOTE: Not all SC ports must be used or dedicated for SC replication, however ports that are used must be in these zones and in the same FC fabric.
NOTE: Do not use Brocade Peer Zoning for Fibre Channel Replication zones.
Deprecated devices
122 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
C Deprecated devices
C.1 Host configurations
The host configurations listed below have been previously tested for use with Dell Storage products, but they are no longer tested by Dell. These
configurations are supported at Level 2 if the vendor is actively providing support, or at Level 3 if vendor support is no longer available.
C.1.1 SC Series
C.1.1.1 HBA and CNA HW initiators
Vendor Operating System OS Version
HBA Vendor
Model Last Driver Last Boot Code
Last FW Adapter
Last Array OS
BfS
Protocol
Apple OS X 6.8 LSI 7x02EP 2.5.0 N/A 1.2.18.0 6.1.x L3 FC
Apple OS X 7x04EP N/A N/A 1.3.23.0 6.2.x L3 FC
Apple OS X 8.2 LSI 7x04EP Built-in N/A 1.3.23.0 6.5.x L3 FC
Apple OS X 9.5 LSI 7x04EP Built-in N/A 1.3.23.0 6.6.x L3 FC
Citrix XenServer 5.6 QLogic QxE25xx N/A N/A N/A 6.3.x L3 FC
Citrix XenServer QLx406x Built-in N/A N/A 5.5.x L3 iSCSI
Citrix XenServer 6.0 Emulex LPx1200x 8.3.5.77.1p 2.12a6 2.00a4 6.2.x L1 FC
Citrix XenServer 6.1 Emulex LPx1200x 8.3.5.77.1p 2.12a10 2.01a10 6.4.x L1 FC
Citrix XenServer 6.2 Emulex LPx1200x 8.3.7.14 5.13a3 2.01a12 6.6.x L1 FC
Citrix XenServer QLogic QxE25xx 8.5.0.3.55.6-k 3.27 7.04.0 6.6.x L1 FC
HP HP-UX 11i v2 Emulex LP900x 4.32.03 N/A 3.93a0 5.2.x L3 FC
HP HP-UX 11i v2 HP A6795A B.11.23.0709 1.37 N/A 6.4.x L3 FC
Deprecated devices
123 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Operating System OS Version
HBA Vendor
Model Last Driver Last Boot Code
Last FW Adapter
Last Array OS
BfS
Protocol
HP Tru-64 5.1A HP FCA2684 2.14 N/A 1.90a4 6.3.x L3 FC
HP OpenVMS 8.3 HP FCA2354 N/A N/A N/A 6.2.x L1 FC
IBM AIX 5.2 Cambex PC200x 2.5.10.39 N/A 3.3.19 5.5.x L3 FC
IBM AIX 5.3 Cambex PC400x 3.0.0.9 N/A 4.00.29 4.x.y L3 FC
IBM AIX IBM 575x 5.3.90 1.50a4 10x8 6.0.x L1 FC
IBM AIX 577D 6.1.6.0 3.10a3 2.00x7 6.2.x L1 FC
IBM AIX 6.1 QLogic QLx405x Built-in N/A N/A 5.3.x L3 iSCSI
Microsoft Windows Server 2003 QLogic QLx405x 2.1.4.26 N/A 3.0.1.53 6.0.x L3 iSCSI
Microsoft Windows Server QLx406x 2.1.4.26 2.09 3.0.1.75 6.6.x L1 iSCSI
Microsoft Windows Server 2003 R2 Emulex LPx1100x 7-2.10a7 5.03a0 2.80a4 5.0.x L3 FC
Microsoft Windows Server 2003 R2 LPx1200x 5.2.70.018 5.13a3 2.01a12 6.7.x L1 FC
Microsoft Windows Server 2003 R2 7.2.50.007 2.12a6 2.00a4 6.0.x L1 FC
Microsoft Windows Server 2003 R2 QLogic QLA23xx 9.1.7.16 1.43 3.3.25 4.x.y L1 FC
Microsoft Windows Server 2003 R2 QxE24xx 9.1.9.27 3.00 5.4.4 6.0.x L1 FC
Microsoft Windows Server 2003 R2 QxE25xx 9.1.9.27 3.13 5.4.4 6.4.x L3 FC
Microsoft Windows Server 2003 R2 QxE81xx 9.1.7.18 N/A 5.1.3 4.x L1 FCoE
Microsoft Windows Server 2008 Emulex LPx1100x 7.230.016 5.03a0 2.82a4 5.4.x L3 FC
Microsoft Windows Server 2008 LPx1200x 7.2.70.014 2.12a6 2.00a4 6.2.x L1 FC
Microsoft Windows Server 2008 QLogic QLA23xx 9.1.7.18 1.54 3.3.25 5.2.x L1 FC
Microsoft Windows Server 2008 QxE24xx 9.1.9.27 3.00 5.4.4 6.0.x L1 FC
Microsoft Windows Server 2008 QxE25xx 9.1.10.26 3.13 5.6.5 6.4.x L1 FC
Deprecated devices
124 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Operating System OS Version
HBA Vendor
Model Last Driver Last Boot Code
Last FW Adapter
Last Array OS
BfS
Protocol
Microsoft Windows Server 2008 QLx405x 2.1.4.19 N/A 3.0.1.53 5.2.x L3 iSCSI
Microsoft Windows Server 2008 QLx406x 2.1.5.25 3.0.1.53 3.0.1.53 5.5.x L2 iSCSI
Microsoft Windows Server 2012 Emulex LPx1600x 10.2.370.8 KT8.03a15
10.0.803.25
6.6.x L1 FC
Microsoft Windows Server OCE1010x-i
10.2.421.0 2.0.1.35 4.16.17 6.6.x L1 iSCSI
Microsoft Windows Server QLogic QxE25xx 9.1.12.21 3.27 7.4.0 6.6.x L1 FC
Microsoft Windows Server QxE266x QLE267x QLE267x
9.1.12.21 3.27 7.4.1 6.6.x L1 FC
Microsoft Windows Server BRCM578xx
7.8.12.0 7.85 7.8.57.0 6.4.x L1 FCoE
Microsoft Windows Server QxE82xx 9.1.11.12 3.23 4.16.17 6.4.x L1 FCoE
Microsoft Windows Server 2.1.6.10 2.0.1.35 4.16.17 6.6.x L1 iSCSI
Microsoft Windows Server QLx406x 2.1.4.27 2.09 3.0.1.75 6.6.x L1 iSCSI
Novell Netware 6.5-SP6 QLogic QLx24xx 6.90o 1.24 4.00.26 4.x.y L3 FC
Novell Netware 6.5-SP7 QLogic QLA23xx 6.90o 1.24 3.03.20 5.3.x L1 FC
Novell Netware 6.5-SP8 QLogic QLA23xx 6.90o 1.5 3.03.21 6.4.x L1 FC
Novell SUSE Linux Enterprise Server
10 Emulex LPx1200x 8.2.0.92.1p 5.13a0 2.01a12 6.5.x L1 FC
Novell QLogic QLx405x 5.01.03.03.10.03-d4 N/A 3.0.1.53 6.0.x L3 iSCSI
Novell QLx406x 5.03.01.11.10.4-d0 N/A 3.0.1.75 6.5.x L3 iSCSI
Oracle Linux Server (UEK) 6.3 QLogic QLx24xx 8.2.0.10.10.3-k4 1.29 4.4.9 6.3.x L1 FC
Oracle Linux Server (UEK) 6.4 QLogic QxE25xx 8.04.00.11.39.o-k 3.20 5.8.0 6.4.x L1 FC
Deprecated devices
125 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Operating System OS Version
HBA Vendor
Model Last Driver Last Boot Code
Last FW Adapter
Last Array OS
BfS
Protocol
Oracle Linux Server (UEK) QxE266x QLE267x
8.04.00.11.39.o-k 3.20 6.4.0 6.4.x L3 FC
Oracle Oracle Virtual Machine 3.2.x QLogic QxE25xx 8.05.00.03.39.0-k1 3.20 5.9.0 6.5.x L3 FC
Oracle QxE266x QLE267x/QLE267x
8.05.00.03.39.0-k1 3.19 6.6.3 6.5.x L3 FC
Oracle Solaris (SPARC) 9 QLogic QLA23xx 2.19 1.43 3.3.119 6.1.x L3 FC
Oracle QLogic QLx401x 5.00 N/A 3.0.0.04 4.x.y L3 iSCSI
RedHat Enterprise Linux 5.0 QLogic QLA23xx 8.01.07-k7 1.43 3.3.20 4.x.y L1 FC
RedHat Enterprise Linux 5.1 QLogic QLA23xx 8.01.07-k7 1.43 3.3.20 4.x.y L1 FC
RedHat Enterprise Linux QLx406x 5.01.01.04 N/A 3.0.1.24 4.x.y L3 iSCSI
RedHat Enterprise Linux 5.2 Emulex LPx1200x 8.2.0.29 5.03a2 1.10a5 4.x.y L3 FC
RedHat Enterprise Linux QLogic QLA23xx 8.02.00-k5 1.43 3.3.26 5.0.x L3 FC
RedHat Enterprise Linux QLx406x 5.01.00-k8 N/A 3.0.1.24 5.0.x L3 iSCSI
RedHat Enterprise Linux 5.3 QLogic QxE24xx 8.02.00.06.05.03-k 1.29 4.4.5 4.x.y L1 FC
RedHat Enterprise Linux QLx406x 5.01.03.04 N/A 3.0.1.53 4.x.y L3 iSCSI
RedHat Enterprise Linux 5.4 QLogic QLA23xx 8.03.00.10.05.04-k 1.43 3.3.26 5.2.x L1 FC
RedHat Enterprise Linux QxE24xx 8.03.00.10.05.04-k 1.29 4.4.9 5.4.x L1 FC
RedHat Enterprise Linux QLx406x 8.03.00.10.05.04-k N/A 3.0.3.26 5.2.x L3 iSCSI
RedHat Enterprise Linux 5.5 QLogic QxE24xx 8.03.01.04.05.05-k 1.29 4.4.9 6.0.x L1 FC
RedHat Enterprise Linux QLx406x 5.01.00.01.05.04-k9 N/A 3.0.1.53 6.0.x L3 iSCSI
RedHat Enterprise Linux 5.7 QLogic QxE24xx 8.03.07.03.05.07-k 3.00 5.3.16 5.5.x L1 FC
Deprecated devices
126 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Operating System OS Version
HBA Vendor
Model Last Driver Last Boot Code
Last FW Adapter
Last Array OS
BfS
Protocol
RedHat Enterprise Linux QLx406x 5.02.15.01.05.07-k0 N/A 3.0.1.53 5.5.x L3 iSCSI
RedHat Enterprise Linux 5.8 QLogic QxE25xx 8.3.7.9.5.8-k 3.13 5.7.0 6.3.x L1 FC
RedHat Enterprise Linux QLx406x 5.02.15.01.05.07-k0 N/A 3.0.1.53 6.3.x L3 iSCSI
RedHat Enterprise Linux 5.9 QLogic QxE25xx 8.3.7.15.5.9-k 3.20 5.9.0 6.4.x L1 FC
RedHat Enterprise Linux QLx406x 5.02.04.05.05.09-d0 N/A 3.0.1.75 6.4.x L3 iSCSI
RedHat Enterprise Linux 5.10 Emulex LPx1200x 8.2.0.128.3p 5.13a0 2.01a12 6.5.x L1 FC
RedHat Enterprise Linux QLogic QxE25xx 8.03.07.15.05.09-k 3.24 7.1.0 6.5.x L1 FC
RedHat Enterprise Linux QLx406x 5.02.04.06.05.10-d0 N/A 3.0.1.75 6.5.x L3 iSCSI
RedHat Enterprise Linux 5.11 Emulex LPx1200x 8.2.0.128.3p 5.13a3 2.01A12 6.6.x L1 FC
RedHat Enterprise Linux QLogic QLx25xx 8.03.07.15.05.09-k 3.27 7.4.0 6.6.x L1 FC
RedHat Enterprise Linux QLx406x 5.02.04.06.05.10-d0 N/A 3.0.1.75 6.6.x L3 iSCSI
RedHat Enterprise Linux 6.0 Emulex LPx1200x 8.3.5.17 5.03a2 1.10a5 6.0.x L1 FC
RedHat Enterprise Linux 6.2 Emulex LPx1200x 8.3.5.68.5p 5.12a9 2.01a10 6.3.x L1 FC
RedHat Enterprise Linux QLogic QLx406x 5.2.15.5.5.6-c0 N/A 3.0.1.53 6.2.x L3 iSCSI
RedHat Enterprise Linux 6.3 Cisco VIC-1280 1.5.0.1 2.2(1c) 2.2(1c) 6.5.x L1 FCoE
RedHat Enterprise Linux Emulex LPx1200x 8.3.5.68.5p 5.12a9 2.01a10 6.3.x L1 FC
RedHat Enterprise Linux QLx406x 5.2.0.0.6.3-k4 N/A 3.0.1.53 6.3.x L3 iSCSI
RedHat Enterprise Linux 6.4 Emulex LPx1200x 8.3.5.68.5p 2.12a11 2.01a11 6.4.x L1 FC
RedHat Enterprise Linux QLogic QxE25xx 8.04.00.08.06.4-k 3.20 5.9.0 6.4.x L1 FC
RedHat Enterprise Linux QLx406x 5.02.0.00.06.03-k4 N/A 3.0.1.75 6.4.x L3 iSCSI
VMware ESX/ESXi 4.0 Emulex LP2100x 8.2.0.30.53 N/A 1.00 5.5.x L1 FC
Deprecated devices
127 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Operating System OS Version
HBA Vendor
Model Last Driver Last Boot Code
Last FW Adapter
Last Array OS
BfS
Protocol
VMware ESX/ESXi LPx1200x 8.2.0.30.53 2.12a6 2.00a4 6.0.x L1 FC
VMware ESX/ESXi QLogic QxE24xx 8.02.01-k1-vmw43 1.29 4.04.09 5.4.x L1 FC
VMware ESX/ESXi QxE25xx 8.02.01-k1-vmw48 3.00 4.04.09 6.0.x L1 FC
VMware ESX/ESXi QxE81xx 841.k1.28.1-1vmw 2.13 5.01.03 6.0.x L1 FCoE
VMware ESX/ESXi QLx406x 5.01.03.1-9vmw N/A 3.00.01.24 5.4.x L3 iSCSI
VMware ESX/ESXi 4.1 Emulex LPx1200x 8.2.1.141.55 2.12a11 2.01a11 6.5.x L1 FC
VMware ESX/ESXi LPe12xx 8.2.1.141.55 6.03x1 2.01a10 6.4.x L1 FC
VMware ESX/ESXi LPx1600x 8.2.1.141.55 1.1.21.4 1.1.21.4 6.4.x L1 FC
VMware ESX/ESXi OCx1010x 8.2.1.141.55 N/A 4.2.324.30 6.3.x L1 FCoE
VMware ESX/ESXi OCx1110x 8.2.1.151.65 4.6.142.10
4.6.142.10 6.5.x L1 FCoE
VMware ESX/ESXi QLogic QxE24xx 841.k1.50.1-1vmw 3.20 5.09.00 6.4.x L1 FC
VMware ESX/ESXi QxE25xx 841.k1.61.1-1vmw 3.20 5.09.00 6.5.x L1 FC
VMware ESX/ESXi QxE266x QLE267x
841.k1.50.1-1vmw 3.24 7.00.01 6.4.x L1 FC
VMware ESX/ESXi BR-M1741-k
3.2.0.0 3.2.1.0 3.2.0.0 6.4.x L3 FCoE
VMware ESX/ESXi QxE81xx 841.k1.61.1-1vmw 3.23 7.00.02 6.5.x L1 FCoE
VMware ESX/ESXi QxE82xx 841.k1.50.1-1vmw 3.23 4.16.17 6.4.x L1 FCoE
VMware ESX/ESXi QLx406x 534.4.7.0-1vmw 2.09 3.00.01.75 6.5.x L3 iSCSI
VMware ESX/ESXi QxE82xx 534.4.7.0-1vmw 2.19 4.16.17 6.5.x L1 iSCSI
VMware ESX/ESXi 5.0 Emulex LPx12xx 8.2.4.141.55 6.03x1 2.01a10 6.3.x L1 FC
Deprecated devices
128 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Operating System OS Version
HBA Vendor
Model Last Driver Last Boot Code
Last FW Adapter
Last Array OS
BfS
Protocol
VMware ESX/ESXi LPx1200x 8.2.4.141.55 2.12a10 2.01a10 6.3.x L1 FC
VMware ESX/ESXi LPx1600x 8.2.4.141.55 1.1.21.4 1.1.21.4 6.3.x L1 FC
VMware ESX/ESXi OCe1010x 8.2.4.141.55 4.2.324.30
5.2.324.30 6.3.x L1 FCoE
VMware ESX/ESXi OCe1110x 8.2.1.141.55 4.4.249.3 4.4.249.3 6.3.x L1 iSCSI
VMware ESX/ESXi QLogic QxE25xx 934.5.6.0-1vmw 3.13 5.06.05 6.3.x L1 FC
VMware ESX/ESXi QxE266x QLE267x QLE267x
934.5.6.0-1vmw 3.17 6.04.00 6.3.x L1 FC
VMware ESX/ESXi BR-M1741-k
3.2.0.0 3.2.0.0 3.2.0.0 6.3.x L1 FCoE
VMware ESX/ESXi QxE81xx 934.5.6.0-1vmw 3.13 5.7.0 6.3.x L1 FCoE
VMware ESX/ESXi QxE82xx 934.5.6.0-1vmw 3.14 4.12.10 6.3.x L1 FCoE
VMware ESX/ESXi 634.5.7.0-1vmw 2.12 4.10.8 6.3.x L1 iSCSI
VMware ESX/ESXi QLx406x 634.5.7.0-1vmw N/A 3.00.01.53 6.3.X L3 iSCSI
VMware ESX/ESXi 5.1 Emulex LPx12xx 10.2.459.0 6.03X1 2.01A12 6.6.x L1 FC
VMware ESX/ESXi LPx1500x 10.0.727.24 1.1.21.4 10.2.506.19
6.6.x L1 FC
VMware ESX/ESXi LPx1600x 10.0.727.24 1.1.21.4 10.2.506.19
6.6.x L1 FC
VMware ESX/ESXi OCx1110x 8.2.4.146.62 4.6.142.10
4.6.142.10 6.5.x L1 FCoE
VMware ESX/ESXi QLogic QxE25xx 934.5.45.0 3.24 7.03.00 6.6.x L1 FC
Deprecated devices
129 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Operating System OS Version
HBA Vendor
Model Last Driver Last Boot Code
Last FW Adapter
Last Array OS
BfS
Protocol
VMware ESX/ESXi QxE266x QLE267x
934.5.20.0-1vmw 3.24 7.00.01 6.5.x L1 FC
VMware ESX/ESXi BR-M1741-k
3.2.1.0 3.2.1.0 3.2.1.0 6.4.x L1 FCoE
VMware ESX/ESXi BRCM578xx
1.711.10.v50.3 N/A 7.10.18 6.6.x L3 FCoE
VMware ESX/ESXi QxE81xx 934.5.20.0-1vmw 3.23 7.0.2 6.5.x L1 FCoE
VMware ESX/ESXi QxE82xx 934.5.45.0 3.23 4.16.101 6.6.x L1 FCoE
VMware ESX/ESXi 5.1 644.5.35 2.19 4.16.101 6.6.x L1 iSCSI
C.1.1.2 SW initiators
Vendor iSCSI Initiator/ Last Initiator Version SCOS iSCSI Boot
Operating System
Citrix XenServer 5.x 6.2.x (2.0-871) 6.5.x, 6.6.x L3
Hewlett-Packard HP-UX 11i B.11.31.03 5.4.2, 5.5.2, 5.5.3, 5.5.4, 6.0.1, 6.0.2, 5.5.10, 6.2.1, 6.3.1
L3
IBM AIX 5.3 5.3.0.50 4.1.x, 4.2.x, 4.5.x, 5.0.x, 5.1.x, 5.2.x, 5.3.x, 5.4.x, 5.5.x, 6.2.x
L3
Microsoft
Windows 2003 R2
5.2.3790.3825
4.2.x, 4.5.x, 5.0.x, 5.1.x 5.2.x, 5.3.x, 5.4.x, 5.5.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, 6.4.x, 6.5.x, 6.6.x
L3
Windows 2008 6.1.6002.18005 5.5.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, 6.4.x L3
Novell Netware 6.5 1.06.03 4.1.x, 4.2.x L3
Deprecated devices
130 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor iSCSI Initiator/ Last Initiator Version SCOS iSCSI Boot
Operating System
SUSE Linux Enterprise Server 10 2.0-868 5.5.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, 6.4.x, 6.5.x L3
Oracle Solaris 10 (SPARC) 20121113-0 7.0.x, 7.1.x L3
Solaris 10(x86) 20120627-0 6.3.x, 6.4.x, 6.5.x, 6.6.x, 6.7.x, 7.0.x, 7.1.x L3
Linux Server UEK 6.3 6.2.0-872.41 5.5.x, 6.3.x L3
Linux Server UEK 6.4 6.2.0-873.-2.0.2 6.4.x L3
RedHat RHEL 5 6.2.0.872-16 6.4.x, 6.5.x, 6.6.x, 6.7.x L3
VMware ESX 3.5 3.5U5 4.1.x, 4.2.x, 4.5.x, 5.0.x, 5.1.x, 5.2.x, 5.3.x, 5.4.x, 5.5.x, 6.0.x
L3
vSphere 4.0 In-Box 4.5.x, 5.0.x, 5.1.x, 5.2.x, 5.3.x, 5.4.x, 5.5.x, 6.0.x
L3
vSphere 4.1/ESXi 4.1 In-Box 5.3.x, 5.4.x, 5.5.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, 6.4.x, 6.5.x
L3
vSphere 5.0 In-Box 5.5.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x L3
vSphere 5.1 In-Box 5.5.x, 6.3.x, 6.4.x, 6.5.x L3
Deprecated devices
131 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
C.1.2 PS Series
C.1.2.1 CNA HW initiators
Vendor Operating System
OS Version
CNA Vendor
Model Last Vendor Driver Last Boot Code
Last PS OS Array OS
BfS
DCB
Microsoft Windows Server 2003 Broadcom BRCM570x 5.2.11.0 N/A N/A 4.0.x L1 N/A
QLogic BCM577xx 5.2.11.0 N/A N/A 4.0.x L1 N/A
QLx405x 2.1.4.26 N/A 3.0.1.53 3.2.8 L1 N/A
QLx406x 2.1.4.26 N/A 3.0.1.53 3.2.8 L1 N/A
2008 Broadcom BRCM570x 5.2.11.0 N/A N/A 4.0.x L1 N/A
QLogic BCM577xx 5.2.11.0 N/A N/A 4.0.x L1 N/A
QLx405x 2.1.4.19 N/A 3.0.1.53 3.2.8 L1 N/A
2012 Broadcom BCM570x 7.12.0.0 7.12.1 7.12.19 9.0.x L1 N/A
BCM577xx 7.12.0.0 7.12.1 7.12.19 9.0.x L1 N/A
Emulex OCE1010x-i 4.2.281.0 2.0.42.0 4.2.324.11 7.1.x L1 L3
OCx1410x 10.6.116.0 10.6.133.10 10.6.144.21 9.0.x L1 L1
QLogic QLx406x 2.1.5.37 N/A 7.1.x L1 N/A
QLx8262 2.1.5.38 2.0.1.35 2.10.37 9.0.x L1 L3
BCM577xx 7.6.51.0 N/A N/A 6.0.x L1 N/A
BCM578xx 7.4.1.0 N/A N/A 6.0.x L1 L1
RedHat Enterprise Linux 5.7 Broadcom BRCM570x 2.6.23 N/A N/A 4.3.6 L3 N/A
5.8 Broadcom BRCM570x 2.7.4.1f N/A N/A 6.0.x L3 N/A
QLogic BRMC577xx 2.7.0.3 N/A N/A 6.0.x L3 L3
5.9 Broadcom BRCM5709 2.7.2.2 N/A N/A 7.1.x L1 N/A
Deprecated devices
132 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Operating System
OS Version
CNA Vendor
Model Last Vendor Driver Last Boot Code
Last PS OS Array OS
BfS
DCB
QLogic BMC578xx 2.7.2.2 N/A N/A 7.1.x L1 N/A
6.1 Emulex OCE10102-i 4.0.323.0 N/A N/A 6.0.x L3 L3
6.2 Broadcom BRCM570x 2.1.11 N/A N/A 6.0.x L3 N/A
QLogic BCM577xx 2.1.11 N/A N/A 6.0.x L3 N/A
6.3 QLogic QxE82xx 5.03.01.11 N/A N/A 7.1.x L1 N/A
VMware ESX/ESXi 4.0 Broadcom BRCM570x 2.70.1k.v50.2 N/A N/A 6.0.x L3 N/A
QLogic BMC577xx 1.8.11t5rc2.8.1-3vmw N/A N/A 6.0.x L3 N/A
Emulex OCE10102-i 2.102.525.9 N/A N/A 5.1.x L3 L3
OCE11102-i 2.102.525.9 N/A N/A 5.1.x L3 L3
4.1 Broadcom BRCM570x 2.70.1k.v50.2 N/A N/A 6.0.x L3 N/A
Deprecated devices
133 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Operating System
OS Version
CNA Vendor
Model Last Vendor Driver Last Boot Code
Last PS OS Array OS
BfS
DCB
VMware QLogic BMC577xx 1.8.11t5rc2.8.1-3vmw N/A N/A 6.0.x L3 N/A
Emulex OCx1010x-i 2.102.525.9 N/A N/A 5.1.x L3 N
OCx1110x-i 2.102.525.9 N/A N/A 5.1.x L3 L3
5.0 Broadcom BRCM570x 2.72.10.v50.2 N/A N/A 6.0.x L3 N/A
QLogic BCM577xx 2.70.1k.v50.2 N/A N/A 6.0.x L3 N/A
BCM578xx 2.70.1k.v50.2 N/A N/A 6.0.x L3 L3
Emulex OCe1010x 2.102.525.9 N/A N/A 5.2.x L3 N/A
OCe1110x 2.102.525.9 N/A N/A 5.2.x L3 L2
5.1 QLogic BCM578xx 2.710.30.v50.4 7.10.11 7.10.18 8.0.x L1 N/A
C.1.2.2 SW initiators
Vendor iSCSI Initiator/ Operating System Initiator Version PS Series OS Version DCB BfS
Microsoft Windows 7 RTM 3.2.8+, 4.x, 5.x, 6.0.x N/A L3
Microsoft Windows Vista RTM 3.2.8+, 4.x, 5.x, 6.0.x N/A L3
Microsoft Windows 2003 2.08 3.2.8+, 4.x, 5.x, 6.0.x N/A L3
Microsoft Windows 2003 R2 5.2.3790.3825 3.2.8+, 4.x, 5.x, 6.0.x N/A L3
Microsoft Windows 2008 6.1.6002.18005 3.2.8+, 4.x, 5.x, 6.0.x N/A L3
Novell SUSE Linux Enterprise Server 10 2.0-870 3.2.8+, 4.x, 5.x N/A L3
Novell Netware All Versions L3
Oracle Enterprise Linux 5 5.5 4.x, 5.x N/A L3
RedHat RHEL 5 6.2.0.872-13 4.x, 5.x, 6.x N/A L3
Deprecated devices
134 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor iSCSI Initiator/ Operating System Initiator Version PS Series OS Version DCB BfS
VMware ESX 3.5 3.5U5 3.2.8+, 4.x N/A L3
VMware vSphere 4.0 In-Box 4.0.6+, 5.1.x, 5.2.x, 6.0.x N/A L3
VMware vSphere 4.1/ESXi 4.1 In-Box 4.0.6+, 5.1.x, 5.2.x, 6.0.x N/A L3
VMware vSphere 5.0 In-Box 5.1.x, 5.2.x, 6.0.x N/A L3
VMware vSphere 5.1 In-Box 5.1.x, 5.2.x, 6.0.x, 7.0.x, 8.0.x N/A L3
Deprecated devices
135 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
C.2 Deprecated switches
The switches listed below have been previously tested for use with Dell Storage products, but they are no longer tested by Dell. These switches are
supported at Level 2 if the vendor is actively providing support, or at Level 3 if vendor support is no longer available.
C.2.1 SC Series and PS Series
Vendor Model Type Last FW Validated
Arista 7148SX Eth EOS4.5.1
Brocade 5100 FC 6.3.0c
Brocade B8000/8000e Conv 7.1.x
Brocade RX Eth 2.8.x
Brocade FGS648P-STK Eth 05.0.1T7e11
Brocade FESX648 Eth 04.2.00T73e2
Brocade FCX648S Eth 06.0.00T7f12
Cisco Catalyst 3750E Family Eth 12.2(35)SE51
Cisco Catalyst 4900M Eth 12.2(40)SG2
Cisco MDS 9124 FC 5.01a
Cisco MDS 9128 FC 5.0.4
Cisco M3130G Eth 12.2(50)SE
Cisco M3130X Eth 12.2(50)SE
Cisco Nexus 50x0 Conv 5.2.x
Dell PowerConnect 5424 Eth 2.0.0.43
Dell PowerConnect 5448 Eth 2.0.0.43
Dell PowerConnect 62xx Eth 3.3.7.x
Deprecated devices
136 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
Vendor Model Type Last FW Validated
Dell PowerConnect 8024 Eth 5.1.x
Dell PowerConnect 8024F Eth 5.1.x
Dell PowerConnect M6220 Eth 5.1.x
Dell PowerConnect B-Series 8000/8000e Conv 7.1.x
Dell PowerConnect B-Series RX Eth 2.8.x
Dell PowerConnect J-Series EX4200 Eth 12.0R1.x
Dell PowerConnect J-Series EX4500 Eth 12.0R9.x
Dell PowerConnect M8024 Eth 5.1.0.x
Extreme Networks X450a-48T Eth 1.0.3.11
HP 3500yl-48G Eth K12.122
Juniper EX4200 Eth 12.0R1.x
Juniper EX4500 Eth 12.0R9.x
McData 4300 FC 9.9.6.2
McData Sphereon 4400 FC 09.01.00.50
McData Sphereon 4500 FC 9.9.0.16
McData Sphereon 4700 FC 9.01.00.50
McData Intrepid 6064 FC 9.01.00.50
Nortel/Avaya ERS5510-48T Eth 5.0.0.21
QLogic 1400 FC 5.0.1.10.0
QLogic SANBox 5600 FC 7.4.0.16.0
QLogic SANBox 5800 FC 7.4.0.16.0
Deprecated devices
137 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
C.2.2 FS Series
Vendor Model
Typ
e
Switch FW EqualLogic (FS7xxx) Compellent (FS8600)
FS OS Version PS OS Version FS OS Version SCOS Version
Dell PowerConnect 62xx Eth 3.3.x 1.0.402 5.2.1 3.0.x 6.4.x
Dell PowerConnect 8024/8024F Eth 5.1.x 3.0.8501 7.0.x 3.0.x 6.1.x
Technical support and additional resources
138 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
D Technical support and additional resources
Dell.com/support is focused on meeting customer needs with proven services and support.
Storage technical documents and videos provide expertise that helps to ensure customer
success on Dell EMC storage platforms.
D.1 Related documentation
See the following referenced or recommended resources related to this document.
• SC Series, PS Series, and FS Series white papers and videos
• SC Series Partner Portal (login required)
• PS Series and FS Series configuration guide
• PS Series Rapid Configuration Portal
D.2 RPQ process
• The Request for Product Qualification (RPQ) service is a request for approval and
support for a non-standard configuration. This service applies specifically to Dell
EMC product implementations into non-standard environments. See RPQ
Homepage for additional details. https://inside.dell.com/docs/DOC-190638