Engineered by APC by Schneider Electric for Dell, NetShelter SX is the next-generation rack enclosure solution designed to address current IT market trends for high-density server and networking applications. With a strong focus on cooling, power distribution, cable management, and environmental monitoring, the NetShelter SX provides a reliable rack-mounting environment for mission-critical equipment. Rack Systems Solutions Designed to simplify cable management and improve power distribution

Dell Rack BrochureThis low-profile, toolless, vertical cable management accessory takes up ZeroU of space within an enclosure, occupying the entire rear-cable channel on one side

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Dell Rack BrochureThis low-profile, toolless, vertical cable management accessory takes up ZeroU of space within an enclosure, occupying the entire rear-cable channel on one side

Engineered by APC™ by Schneider Electric™ for Dell,™ NetShelter™ SX is the next-generation rack enclosure solution designed to address current IT market trends for high-density server and networking applications. With a strong focus on cooling, power distribution, cable management, and environmental monitoring, the NetShelter SX provides a reliable rack-mounting environment for mission-critical equipment.

Rack Systems SolutionsDesigned to simplify cable management and improve power distribution

Page 2: Dell Rack BrochureThis low-profile, toolless, vertical cable management accessory takes up ZeroU of space within an enclosure, occupying the entire rear-cable channel on one side

2

Step 1: Select your rack.

Cable Access Roof•Toollessremoval•8largecable-entryslots• Integrationwithoverheadcabletroughandpartitionsystem

Half-Height Side Panels•Easyandsafehandling•Lockable

Easily Adjustable Vertical Mounting Rails•Justturnbolt,noloosehardware•1/4inch(6mm)increments•Automaticalignment

Rear Cable Channels•ToollesslymountPDUs•Toollesslymountverticalcableorganizers

NetShelter SX offers multiple features that increase the flexibility and ease-of-use of the enclosure.

APC Item # Dimensions(H x W x D) Features

Mixed Equipment(servers, networking, and UPS in the same

enclosure)

1U/2U Servers

Blade Servers

Networking Equipment

AR3100X717 42Ux600x1,070 Dell-brandedstandardpremiumenclosure X X

AR3150 42Ux750x1,070 Widerformorecablemanagementandimprovedrearaccess X X X X

AR3300 42Ux600x1,200 Deeperforimprovedrearaccessandmorerear-mountedaccessories X X

AR3350 42Ux750x1,200 Deeperandwider X X X X

AR3107 48Ux600x1,070 AdditionalUspaces X X

AR3157 48Ux750x1,070AdditionalUspaces,andwiderformore

cablemanagementandimprovedrearaccess

X X X X

AR3307 48Ux600x1,200AdditionalUspaces,anddeeperforimprovedrearaccessandmore

rear-mountedaccessoriesX X

AR3357 48Ux750x1,200 AdditionalUspaces,wideranddeeper X X X X

AR3104X717 24Ux600x1,070 Dell-brandedshorterrackforbranchoffices,tighterspaceandlowerdensity X X

1

2

3

41

2

3

4

Page 3: Dell Rack BrochureThis low-profile, toolless, vertical cable management accessory takes up ZeroU of space within an enclosure, occupying the entire rear-cable channel on one side

3

Step 2: Select your rack power distribution.

Metered-by-Outlet with Switching Rack PDUThisPDUprovidesreal-timeremotemonitoringofeachindividualoutlettoempowerITprofessionalswiththenecessarytoolsforadvanceddatacenterenergymanagement.

•LocalandWeb-basedmonitoring•Comprehensive,real-timeloadmonitoringatoutletlevel•Remotecontrolofindividualoutlets•Outletlevelgrouping

Switched Rack PDUTheSwitchedRackPDUprovidesadvancedloadmonitoringcombinedwithremoteON/OFFswitchingcontrolofindividualoutletsforpowercycling,delayedpowersequencing,andoutlet-usemanagement.

•LocalandWeb-basedmonitoring•Remotecontrolofindividualoutlets•Outletpower-upsequencing•Lockunusedoutletsforpower-userestrictionsandaccesscontrol

APC Item # Description Mounting Load Capacity Voltage Input Cord

LengthOutput

Connections

AP8641RackPDU2G,Metered-by-Outlet

withSwitching,ZeroU,30A,200/208V,(21)C13&(3)C19

Vertical 5.0kW 208V NEMA®L6-30P 3.0m (21)IEC®320C13(3)IEC320C19

AP8653RackPDU2G,Metered-by-Outlet

withSwitching,ZeroU,32A,230V,(21)C13&(3)C19

Vertical 7.4kW 230V IEC30932A2P+E 3.0m (21)IEC320C13(3)IEC320C19

AP8659RackPDU2G,Metered-by-OutletwithSwitching,ZeroU,20A/208V,16A/230V,(21)C13&(3)C19

Vertical 3.3kW 100–240V IEC320C20 Inlet (21)IEC320C13(3)IEC320C19

AP8681RackPDU2G,Metered-by-OutletwithSwitching,ZeroU,11kW,(21)

C13&(3)C19Vertical 11kW 400V IEC30916A

3P+N+PE 1.8m (21)IEC320C13(3)IEC320C19

APC Item # Description Mounting Load Capacity Voltage Input Cord

LengthOutput

Connections

AP8953 RackPDU2G,Switched,ZeroU,32A,230V,(21)C13&(3)C19 Vertical 7.4kW 230V IEC30932A2P+E 3.0m (21)IEC320C13

(3)IEC320C19

AP8941 RackPDU2G,Switched,ZeroU,30A,200/208V(21)C13&(3)C19 Vertical 5.0kW 208V NEMAL6-30P 3.0m (21)IEC320C13

(3)IEC320C19

Page 4: Dell Rack BrochureThis low-profile, toolless, vertical cable management accessory takes up ZeroU of space within an enclosure, occupying the entire rear-cable channel on one side

4

Metered Rack PDUTheMeteredRackPDUprovidesreal-timeremotemonitoringofconnectedloads.User-definedalarmswarnofpotentialcircuitoverloadsbeforecriticalITfailuresoccur.

•LocalandWeb-basedmonitoring•ActivepowermeteringatPDUlevel•User-definedalarmthresholds•Widerangeofinputandoutputconnections

Step 2 (continued)

APC Item # Description Mounting Load Capacity Voltage Input Cord Length Output Connections

AP7830 RackPDU,Metered,ZeroU,20A,120V,(24)NEMA5-20R Vertical 1.9kW 120V NEMAL5-20P 3.0m (24)NEMA5-20R

AP7832 RackPDU,Metered,ZeroU,30A,100V,(24)NEMA5-15R Vertical 2.9kW 120V NEMAL5-30P 3.0m (24)NEMA5-20R

AP8841 RackPDU2G,Metered,ZeroU,30A,208V,(36)C13&(6)C19 Vertical 5.0kW 208V NEMAL6-30P 3.0m (36)IEC320C13

(6)IEC320C19

AP8853 RackPDU2G,Metered,ZeroU,32A,230V,(36)C13&(6)C19 Vertical 7.4kW 230V IEC30932A

2P+E 3.0m (36)IEC320C13(6)IEC320C19

AP8858 RackPDU2G,Metered,ZeroU,20A/208V16A/230V,(18)C13&(2)C19 Vertical 3.3kW 100–

240V IEC-320C20 Inlet (18)IEC320C13(2)IEC320C19

AP8865 RackPDU2G,Metered,ZeroU,8.6kW,208V,(36)C13&(6)C19&(2)5-20R Vertical 8.6kW 208V3Ph NEMAL21-30P 1.8m

(36)IEC320C13(6)IEC320C19(2)NEMA5-20R

AP8866 RackPDU2G,Metered,ZeroU,17.2kW,208V,(6)C13&(12)C19 Vertical 17.3kW 208V3Ph IEC30960A

3P+PE 1.8m (6)IEC320C13(12)IEC320C19

AP8868 RackPDU2G,Metered,ZeroU,10.0kW,208V,(36)C13&(6)C19 Vertical 10.0kW 208V3Ph CS8365C 1.8m (36)IEC320C13

(6)IEC320C19

AP8881 RackPDU2G,Metered,ZeroU,11kW,(36)C13&(6)C19 Vertical 11kW 400V3Ph IEC30916A

3P+N+PE 1.8m (36)IEC320C13(6)IEC320C19

AP8886 RackPDU2G,Metered,ZeroU,22.0kW,(30)C13&(12)C19 Vertical 22kW 400V3Ph IEC30932A

3P+N+PE 1.83m (30)IEC320C13(12)IEC320C19

Next Generation PDU Features (AP8000 series)

APC Exclusive Locking IEC Connectors

New Interactive LCD Display and Advanced Remote Management

Environmental Monitoring – Exc Sensor (AP9335T or AP9335TH)

Industry’s First Ultra-Low-Profile Breakers

For assistance with selecting the correct Rack PDU, and to view the entire range, please visit: www.dellups.com/select-PDU.asp

For More Information on Rack PDU and Rack PDU Selector

Page 5: Dell Rack BrochureThis low-profile, toolless, vertical cable management accessory takes up ZeroU of space within an enclosure, occupying the entire rear-cable channel on one side

5

Basic Rack PDUTheBasicRackPDUprovidesreliablepowerdistributionviaasingleinputwithmultipleoutputreceptaclesanddistributespowerfromlow-amperage,single-phasecircuitstohigher-power3-phasesolutions.

•Reliablepowerdistribution•Widerangeofinputandoutputconnections

AR7707Largecapacityverticalcablemanagementringsfacilitatecableroutingintypicalnetworkingenvironments,mountingtothefrontrailsofthe29.5”-wideenclosures.

AR7710Thislow-profile,toolless,verticalcablemanagementaccessorytakesupZeroUofspacewithinanenclosure,occupyingtheentirerear-cablechannelononeside.

AR8442Thistoolless,verticalcablemanagementaccessorythatallowsforquickinstallation,andtakesupZeroUofspacewithintheenclosure.Itoccupiesonehalfoftherear-cablechannel,enablingaverticalrackPDUtobemountedbesideit.

Vertical Cable Management

APC Item # Description Mounting Load Capacity Voltage Input Cord Length Output Connections

AP9559 RackPDU,Basic,1U,16A,208V/230V,(10)C13&(2)C19 Horizontal 3.7kW 120–

240V IEC-320C20 2.5m (10)IEC320C13(2)IEC320C19

AP9562 RackPDU,Basic,1U,15A,120V,(10)5-15R Horizontal 1.4kW 100–

120V NEMA5-15P 3.6m (10)NEMA5-15R

AP9565 RackPDU,Basic,1U,16A,208/230V,(12)C13 Horizontal 3.7kW 100–

240V IEC-320C20 2.5m (12)IEC320C13

AP9571A RackPDU,Basic,1U,30A,208V,(10)C13 Horizontal 5.0kW 200–

240V NEMAL6-30P 3.6m (10)IEC320C13

AP9572RackPDU,Basic,ZeroU,16A,208/230

V,(15)C13 Vertical 3.6kW 120–230V IEC-320C20 2.5m (15)IEC320C13

AP7541 RackPDU,Basic,ZeroU,30A,200/208V,(20)C13&(4)C19 Vertical 5.0kW 200–

240V NEMAL6-30P 3.0m (20)IEC320C13(4)IEC320C19

AP7553 RackPDU,Basic,ZeroU,32A,230V,(20)C13&(4)C19 Vertical 7.4kW 230V IEC30932A

2P+E 3.05m (20)IEC320C13(4)IEC320C19

AP7557 RackPDU,Basic,ZeroU,11kW,(36)C13&(6)C19 Vertical 11kW 400V3Ph IEC30916A

3P+N+PE 0.91m (36)IEC320C13(6)IEC320C19

APC Item # Description Cable Space (mm) Cat6 Cable Qty

AR8442 VerticalCableOrganizer,8CableRings,ZeroU(qty.2) 38x64 54

AR7710 NEW!CableContainmentBracketswithPDUMountingCapabilityforNetShelter 38x108 91

AR7707 CableManagementRings,8-inchDeep,NetShelterSX,750mmWide(qty.8) 57x187 236

Step 3: Select your cable management.

Page 6: Dell Rack BrochureThis low-profile, toolless, vertical cable management accessory takes up ZeroU of space within an enclosure, occupying the entire rear-cable channel on one side

6

Power Cable TroughTroughsystemsallowforoverheadroutingofpowercables/whipsontopoftheNetShelterenclosures.Thetroughsattachwithouttoolstotheroofforeaseofinstallation.

Data Cable PartitionThedatacablepartitionallowsoverheadroutingofnetworkingcablesontopoftheNetShelterenclosures.Partitionstoollesslyattachtotheroofinavarietyoflocations.Thesolidpartitionisdesignedtobemountedinthefrontforacleanlook.

Cable LadderCableladdersareavailablein152-mmand304-mmwidthsforroutingpoweranddatacablesbetweenrowsandaisles.Includeshardwarefortoollessmountingtotroughsandpartitions.

Overhead Cable Management

Step 3 (continued)

Horizontal Cable Management

AR8425A and AR8426AThiscable-managementaccessoryhelpstoeliminatecablestressandmaintainaneat,organizedcablelayoutwithinanenclosureorarack.

AR8428AR8428facilitatesfront-cablemanagementwhileallowingcablestopassthroughtorearappliances,occupying2Uofrackspace.

6

APC Item # Description U Height Cable Space (mm) Cat6 Cable Qty

AR8425A HorizontalCableOrganizer1U 1U 38x64 54

AR8426A HorizontalCableOrganizer2U 2U 70x64 99

AR8428 HorizontalCableOrganizer2Uw/Pass-throughholes 2U 70x64 99

Page 7: Dell Rack BrochureThis low-profile, toolless, vertical cable management accessory takes up ZeroU of space within an enclosure, occupying the entire rear-cable channel on one side

7

Blanking PanelsModulartoolless1UAirflowManagementBlankingPanelpreventsairrecirculationbyoccupyingunusedrackspace.

APC Item # Width Description

AR8162ABLK 600 SolidDataCablePartition

AR8163ABLK 600 DataCablePartitionw/Pass-through

AR8172BLK 750 SolidDataCablePartition

AR8173BLK 750 DataCablePartitionw/Pass-through

AR8164ABLK 152 CableLadder6”(15cm)Widew/AttachmentKit

AR8165ABLK 304 CableLadder12”(30cm)Widew/AttachmentKit

AR8560 600 PowerCableTrough,OpenBottom

AR8561 600 PowerCableTrough

AR8570 750 PowerCableTrough,OpenBottom

AR8571 750 PowerCableTrough

AR8567 TroughEndCap

APC Item # Description Rack Height

AR8136BLK 1U19”BlackModularToollessAirflowManagementBlankingPanel(qty.10) 10U

AR8136BLK200 1U19”BlackModularToollessAirflowManagementBlankingPanel(qty.200) 200U

AR8101BLK AirflowManagementBlankingPanelKit(1U,2U,4U,8U)Black 15U

AR7720 KoldLokRaisedFloorGrommets N/A

For More Information on Cable ManagementVisit the Dell/APC Technical Center site:

Application Note 137: en.community.dell.com/techcenter/extras/m/white_papers/20237730.aspx

Application Note 133: en.community.dell.com/techcenter/extras/m/white_papers/20438208.aspx

KoldLok Raised Floor Grommets Thesepreconfiguredcable-containmentdevicesareusedtocovercablecutoutsinaraised-floorenvironmentandassistinmanagingairflowwhilestillallowingforamplecablepass-through.

Step 4: Select Airflow Management.

Page 8: Dell Rack BrochureThis low-profile, toolless, vertical cable management accessory takes up ZeroU of space within an enclosure, occupying the entire rear-cable channel on one side

Step 5: Select Mounting Hardware.

Shelving

AR8122BLK and AR8105BLKFixedshelfenablesmountingoftowerunits,monitors,andotherequipmentintotherackenvironment.

AR8123BLK and AR8128BLKSlidingshelfenablesmountingoftowerunits,monitors,andotherequipmentintotherackenvironment.

AR8126ABLKPull-outdrawerdesignallowsforeasyaccessandout-of-the-waystorageforallstandard17-inchkeyboards.

Hardware and Mounting Kits

AR8100M6hardwareallowsformountingequipmentinenclosurewithsquare-holemountingrails(32setsofM6cagenuts,nylonwashers,andslot/Phillipsscrews).

AR8006AIdealformountingnon-rackmountableequipmentinarack,theserailscansupportequipmentmeasuringupto16.75”(43cmto17.7”(45cm)wideandhasamaximumweightof200lb/91kg.

AR7701Equippedwithbolt-downbracketsforNetShelterSXenclosures,AR7701meetsUBCZone-4seismic-anchoringrequirements.

AR7700Built-instabilizationplatespreventtip-overinstand-alonerackapplications.

APC Item # Description Rack Height

AR8122BLK FixedShelf114kgBlack 1U

AR8105BLK FixedShelf22.7kgBlack 2U

AR8123BLK SlidingShelf45.5kgBlack 1U

AR8128BLK SlidingShelf91kgBlack 1U

AR8126ABLK 17”KeyboardDrawerBlack 1U

APC Item # Description

AR8100 M6HardwareKit

AR8006A EquipmentSupportRailsfor600-mm-wideEnclosure

AR7701 NetShelterSXBolt-downKit

AR7700 NetShelterSXStabilizerPlate

APC Item # Description

AP5717 APC17”RackLCDConsole

AP5719 APC19”RackLCDConsole

APC Item # Description

AP5808 APC17”RackLCDConsoleWithIntegrated8-portKVMSwitch

AP5816 APC17”RackLCDConsoleWithIntegrated16-portKVMSwitch

AP5821 KVMUSBCable1.8m

AP5822 KVMUSBCable3.0m

AP5823 KVMUSBCable5.2m

©2014 Schneider Electric. All Rights Reserved. Schneider Electric, APC, and NetShelter are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners. • email: [email protected] • 132 Fairgrounds Road, West Kingston, RI 02892 USA • 998-1236082_GMA-US

Step 6: Select Rackmount Consoles.

•Ultra-thin17”or19”LCDMonitor• Integratedkeyboardwithnumberpad•USBportforexternalmedia•Space-saving1Udesign•Touchpadmouse•Easytoinstall