SECTION 07 95 00 EXPANSION CONTROL SYSTEMS Display hidden notes to specifier. (Don't know how? Click Here ) Copyright 2006 - 2015 ARCAT, Inc. - All rights reserved 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Exterior Expansion Control Systems. 1.1.2 Metallic Expansion Control Systems. 1.1.3 Wall and Ceiling Covers. 1.1.4 Exterior Seals and Covers. 1.1.5 Interior seals. 1.1.6 Roof seals. 1.1.7 Associated Materials, adhesives, fire barriers, sealant, water barriers, etc. 1.2 RELATED SECTIONS 1.2.1 Section 03 30 00 - Cast-in-Place Concrete. 1.2.2 Section 03 45 13 - Faced Architectural Precast Concrete. 1.2.3 Section 04 20 00 - Unit Masonry. 1.2.4 Section 05 12 16 - Fabricated Fireproofed Steel Columns. 1.2.5 Section 05 40 00 - Cold-Formed Metal Framing. 1.2.6 Section 07 62 00 - Sheet Metal Flashing and Trim. 1.2.7 Section 07 90 00 - Joint Protection. 1.3 REFERENCES 1.3.1 ASTM A36 - Standard Specification for Carbon Structural Steel. 1.3.2 ASTM A588 - Standard Specification for High-Strength Low-Alloy 07 95 00-1

· Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

Embed Size (px)

Citation preview

Page 1: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

SECTION 07 95 00EXPANSION CONTROL SYSTEMS

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2006 - 2015 ARCAT, Inc. - All rights reserved

1 GENERAL

1.1 SECTION INCLUDES

1.1.1 Exterior Expansion Control Systems.

1.1.2 Metallic Expansion Control Systems.

1.1.3 Wall and Ceiling Covers.

1.1.4 Exterior Seals and Covers.

1.1.5 Interior seals.

1.1.6 Roof seals.

1.1.7 Associated Materials, adhesives, fire barriers, sealant, water barriers, etc.

1.2 RELATED SECTIONS

1.2.1 Section 03 30 00 - Cast-in-Place Concrete.

1.2.2 Section 03 45 13 - Faced Architectural Precast Concrete.

1.2.3 Section 04 20 00 - Unit Masonry.

1.2.4 Section 05 12 16 - Fabricated Fireproofed Steel Columns.

1.2.5 Section 05 40 00 - Cold-Formed Metal Framing.

1.2.6 Section 07 62 00 - Sheet Metal Flashing and Trim.

1.2.7 Section 07 90 00 - Joint Protection.

1.3 REFERENCES

1.3.1 ASTM A36 - Standard Specification for Carbon Structural Steel.

1.3.2 ASTM A588 - Standard Specification for High-Strength Low-Alloy Structural Steel with 50 ksi Minimum Yield Point to 4-in. Thick.

1.3.3 ASTM A666 - Standard Specification for Annealed or Cold-Worked Austenitic Sheet, Strip, Plate and Flat Bar.

1.3.4 ASTM B209 - Standard Specification for Aluminum and Aluminum Alloy Sheet and Plate.

07 95 00-1

Page 2: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

1.3.5 ASTM B 221 - Standard Specification for Aluminum and Aluminum Alloy Extruded Bars, Rods, Wire, Shapes and Tubes.

1.3.6 ASTM D 2000 - Standard Classification System for Rubber Products in Automotive Applications.

1.3.7 ASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene.

1.3.8 ASTM C 864 - Standard Specification for Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers - Santoprene Extrusions.

1.3.9 ASTM D 4030 - Standard Specification for Ultra-High-Molecular-Weight Polyethylene Molding and Extrusion Materials.

1.3.10 ASTM D 4070 - Standard Specification for Adhesive Lubricant for Installation of Preformed Elastomeric Bridge Compression Seals in Concrete Structures.

1.3.11 ASTM D 4637 - Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane.

1.3.12 ASTM E 119 - Standard Test Methods for Fire Tests of Building Construction and Materials.

1.3.13 ASTM E 814 - Standard Test Methods of Penetration Firestop Systems.

1.3.14 ASTM E 1399 - Standard Test Method for Cyclic Movement and Measuring the Minimum and Maximum Joint Widths of Architectural Joint Systems.

1.3.15 ASTM E 1966 - Standard Test Method for Fire-Resistive Joint Systems.

1.3.16 UL 2079 - Tests for Fire Resistance of Building Joint Systems.

1.4 PERFORMANCE REQUIREMENTS

1.4.1 Fire Test Characteristics: Install expansion control systems tested by an independent, accredited testing and listing entity in accordance with ASTM E814/119 or E1966 or UL 2079 at its full rated period.1.4.1.1 Fire Rating: 2 hours.1.4.1.2 Fire Rating: 3 hours.1.4.1.3 Fire Rating: 4 hours.1.4.1.4 Fire Rating: Equal to or greater than the fire rating of the surrounding

construction.

1.4.2 Seismic Requirements:1.4.2.1 Movement X Axis: 50 percent of nominal.1.4.2.2 Movement X Axis: 100 percent of nominal.1.4.2.3 Movement X Axis: __ percent of nominal.1.4.2.4 Movement Y Axis: 50 percent of nominal.1.4.2.5 Movement Y Axis: 100 percent of nominal.1.4.2.6 Movement Y Axis: __ percent of nominal.1.4.2.7 Movement Z Axis: 50 percent of nominal.1.4.2.8 Movement Z Axis: 100 percent of nominal.1.4.2.9 Movement Z Axis: __ percent of nominal.

1.5 SUBMITTALS

1.5.1 Submit under provisions of Section 01 30 00 - Administrative Requirements.

07 95 00-2

Page 3: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

1.5.2 Product Data: Manufacturer's data sheets on each product to be used, including:1.5.2.1 Preparation instructions and recommendations.1.5.2.2 Storage and handling requirements and recommendations.1.5.2.3 Installation methods.

1.5.3 Shop Drawings:1.5.3.1 Submit Manufacturer's standard details for each applicable condition found on

the project.1.5.3.2 Special condition details must be reviewed and approved by the Architect in

writing prior to installation. Preparation of alternate or non-standard details is the responsibility of the Contractor.

1.5.4 Manufacturer's Certificates: Certify products meet or exceed specified requirements.1.5.4.1 Submit listings or test reports affirming compliance with all federal, state, and

local building and life safety codes.1.5.4.2 Special condition details must be reviewed and approved by the Architect in

writing prior to installation. Preparation of alternate or non-standard details is the responsibility of the Contractor.

1.5.5 Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.

1.5.6 Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.

1.5.7 Closeout Submittals: Provide manufacturer's maintenance instructions that include recommendations for periodic checking and adjustment of all components.

1.6 QUALITY ASSURANCE

1.6.1 Manufacturer Qualifications:1.6.1.1 All primary products specified in this section shall be provided by a single

manufacturer with a minimum of 10 years experience in the design and fabrication of expansion joint cover assemblies.

1.6.1.2 Manufacturers shall be ISO 9001-2000 Certified with documented management and control of the processes that influence the quality of its products and customer service.

1.6.2 Installer Qualifications:1.6.2.1 All products listed in this section shall be installed by a single installer with

demonstrated experience in installing products of the same type and scope as specified.

1.6.2.2 Installer shall be insured and licensed as required by agencies within the project's jurisdiction and acceptable or authorized by the manufacturer.

1.6.3 Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.1.6.3.1 Finish areas designated by Architect.1.6.3.2 Do not proceed with remaining work until workmanship, color, and sheen are

approved by Architect.1.6.3.3 Refinish mock-up area as required to produce acceptable work.

1.7 DELIVERY, STORAGE, AND HANDLING

1.7.1 Store products in manufacturer's unopened packaging with labels intact until ready for installation.

07 95 00-3

Page 4: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

1.7.2 Store products under cover in a dry, cool location. Store off the ground; protect from freezing, direct sun exposure, weather and construction activities. Store all resin components, at temperatures between 50 degrees F and 80 degrees F (10 C to 27 C).

1.8 SEQUENCING

1.8.1 Ensure that locating templates and other information required for installation of products of this section are furnished to affected trades in time to prevent interruption of construction progress.

1.8.2 Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.

1.9 PROJECT CONDITIONS

1.9.1 Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.10 WARRANTY

1.10.1 Warranty: The specified products are warranted when installed in strict accordance with the manufacturer's technical specifications, details, installation instructions and general procedures as well as good industry practice in effect for normal traffic usage and suitable applications under specific design movements and loading conditions.1.10.1.1 Warranty Duration: 3 years.

2 PRODUCTS

2.1 MANUFACTURERS

2.1.1 Acceptable Manufacturer: Balco, Inc., which is located at: 2626 S. Sheridan P. O. Box 17249; Wichita, KS 67217-0249; Toll Free Tel: 800-767-0082; Tel: 316-945-9328; Fax: 316-945-0789; Email:request info ([email protected]); Web:www.balcousa.com

2.1.2 Substitutions: Not permitted.

2.1.3 Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.

2.2 BALCO EXPANSION CONTROL SYSTEMS

2.2.1 Exterior Expansion Joint Systems:2.2.1.1 Balco Duraflex ARS Series Seal: Watertight expansion control system capable of

accommodating multi-directional movement. Fabricated of channeled aluminum rails which lock an extruded elastomeric chambered seal. Secured using ambient-cured elastomeric concrete nosing material.

2.2.1.1.1 Seal Material: Santoprene; Black Finish.2.2.1.1.1.1 Tensile strength: ASTM D 412: minimum 1000 psi (Mpa).2.2.1.1.1.2 Ultimate elongation: ASTM D 412: Minimum 410 percent.2.2.1.1.1.3 Hardness: Type A durometer - ASTM D 2240 mod.: 73.2.2.1.1.1.4 Compression Set 77 degrees F: ASTM D 395, Method B (mod.):

24.2.2.1.1.1.5 Compression Set: 168 hrs, 212 degrees F: ASTM D 395, Method

B (mod.): 36 percent.2.2.1.1.1.6 100 percent modulus: ASTM D 412, 420 psi.2.2.1.1.1.7 Tear strength, ASTM D 624, 140 lbs/inch.2.2.1.1.1.8 Tension set, ASTM D 412: 10 percent.

07 95 00-4

Page 5: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.1.1.1.9 Specific gravity, ASTM D 792: 0.97.2.2.1.1.1.10 Brittle point, ASTM D 746: -81 F (-63C).

2.2.1.1.2 Aluminum Rail: ASTM B 221, alloy 6061-T6; Mill Finish.2.2.1.2 Balco Duraflex BCS Series Seal : Pre-compressed polyurethane, microcell foam

seal:2.2.1.2.1 Seal Material: Polyurethane Foam.

2.2.1.2.1.1 Density: 5.5-6.5 lb./cu. ft.2.2.1.2.1.2 Thermal Conductivity: 0.28-0.30 Btu-in/hr-F-sqft.2.2.1.2.1.3 Temp. Stability Range: -40 F to 194 F (-40 C to 90 C).2.2.1.2.1.4 Staining/Bleeding, DIN 18542: Pass.2.2.1.2.1.5 Tensile Strength, ASTM D 3574: Meets 21 psi minimum.2.2.1.2.1.6 Elongation, ASTM D 3574: 120 percent +/- 20 percent.2.2.1.2.1.7 Resistance to Compression Set, ASTM D 3574: Max 4.2 percent.2.2.1.2.1.8 Mildew Resistance: Excellent.2.2.1.2.1.9 Staining: None.2.2.1.2.1.10 Fire testing, ASTM E 84: Flame spread 0, Smoke developed 5.2.2.1.2.1.11 Water resistance, ASTM E 547 and ASTM E 331: 12 psf.

2.2.1.2.2 Type: BCSF.2.2.1.2.2.1 Finish: Grey.

2.2.1.2.3 Type: BCSW.2.2.1.2.3.1 Finish: Dow Corning 790 Silicone Sealant.2.2.1.2.3.2 Color: To be selected by Architect from available color range.

2.2.1.3 Balco Duraflex CS Series Chambered Seal: Extruded thermoplastic compound (Santoprene) with factory-punched holes in the flaps through which the nosing material bonds the gland to the deck, ensuring leak resistance and proper joint performance.

2.2.1.3.1 Seal Material: Santoprene.2.2.1.3.1.1 Tensile strength, minimum, ASTM D 412: 1050 psi (Mpa).2.2.1.3.1.2 Ultimate elongation, minimum, ASTM D 412: 410 percent.2.2.1.3.1.3 Hardness, Type A Durometer, ASTM D 2240 mod.: 67 plud or 3.2.2.1.3.1.4 Compression Set, 77 degrees F, ASTM D 395, Method B (mod.):

23.2.2.1.3.1.5 Compression Set, 168 hrs, 212 degrees F, ASTM D 395, Method

B (mod.): 36 percent.2.2.1.3.1.6 100 percent modulus, ASTM D 412: 420 psi.2.2.1.3.1.7 Tear strength, ASTM D 624: 140 lbs/inch.2.2.1.3.1.8 Tension set, ASTM D 412: 10 percent.2.2.1.3.1.9 Brittle point, ASTM D 746: minus 81 degrees F (minus 63 degrees

C).2.2.1.3.2 Finish: Black.

2.2.1.4 Balco Duraflex ES Series Elastic Seal: Preformed and extruded elastomer vulcanized into its proprietary shape.

2.2.1.4.1 Seal Material: EPDM.2.2.1.4.1.1 Tensile strength, minimum, ASTM D 412: 1500 to 2000 psi (Mpa).2.2.1.4.1.2 Elongation at break, minimum, ASTM D 412: 350 to 400 percent.2.2.1.4.1.3 Hardness, Type A Durometer, ASTM D 2240 mod.: 65 plus or

minus 5.2.2.1.4.1.4 Oven aging, 70h at 212 degrees F (100 degrees C):

2.2.1.4.1.4.1 Tensile strength, maximum loss: 15 percent.2.2.1.4.1.4.2 Elongation, maximum loss: 40 percent.2.2.1.4.1.4.3 Hardness, Type A durometer: 0 to 10.

2.2.1.4.1.5 Ozone resistance, ASTM D 1149: 20 percent strain, 303 Mpa of ozone in air (the volume fraction of ozone is 300 pphm in air at 1 atm), 70h at 104 degrees F (40 degrees C), wiped with toluene to remove surface contamination: No cracks.

2.2.1.4.2 Finish: Black.

07 95 00-5

Page 6: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.1.5 Balco DuraFlex FCWW Series: Extruded aluminum subchannels, extruded elastomeric face seal and an extruded elastomeric back seal sized to accommodate the total range of movement at each joint location without disengagement of the cover.

2.2.1.5.1 Allowable movement: As specified for each floor or plane.2.2.1.5.2 Extruded Aluminum Subchannel, Aluminum, ASTM B 221, alloy 6063-T5;

Mill Finish.2.2.1.5.3 Elastomeric Face Seal: Santoprene, UV resistant grade.2.2.1.5.4 Elastomeric Face Seal: Silicone, ASTM D 2000, 4GE709M.2.2.1.5.5 Face Seal Finish: Black.2.2.1.5.6 Face Seal Finish: White.2.2.1.5.7 Face Seal Finish: Tan.2.2.1.5.8 Face Seal Finish: Gray.2.2.1.5.9 Face Seal Finish: Color to be selected by Architect from available color

choices.2.2.1.5.10 Back Seal: Santoprene, extruded: Black Finish.

2.2.1.6 Balco DuraFlex FS Series: Watertight extruded neoprene expansion control system capable of accommodating multi-directional movement. Seal profile adhered to the joint interface walls using a high-strength epoxy adhesive. Metal cover plate is mechanically fastened to the substrate if the nominal joint width is greater than 1 inch or pedestrian or vehicular traffic is present.

2.2.1.6.1 Tensile strength, minimum, ASTM D 412: 125 psi.2.2.1.6.2 Elongation at break, minimum, ASTM D 412: 200 percent.2.2.1.6.3 Hardness, Shore "00" Durometer, ASTM D 2240 mod.: 35-65.2.2.1.6.4 Compression deflection, ASTM D 1056: 5-9 psi.2.2.1.6.5 Water absorption, (by weight), ASTM D 1056: 5 percent.2.2.1.6.6 Density, ASTM D 1056: 12-25 pcf, average.

2.2.1.7 Balco DuraFlex HD Series Heavy Duty Parking Garage System: Joint system permits unrestrained movement of the joint without disengagement of the cover.

2.2.1.7.1 Model: HDN - Extruded aluminum subchannels and a metal center plate which spans the joint. Centering Bars with nylon spheres which fully engage with the subchannel's tracks.

2.2.1.7.1.1 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill finish.

2.2.1.7.1.2 Extruded Center Plate: Aluminum, ASTM B 221, alloy 6063-T5; Mill finish.

2.2.1.7.1.3 Centering Bar: Spring Steel, Alloy 1074, Tempered.2.2.1.7.2 Model: XH Extruded aluminum subchannels and a metal center plate

which spans the joint.2.2.1.7.2.1 Extruded Cover Plate: Aluminum, ASTM B 221, alloy 6063-T5; Mill

finish.2.2.1.7.2.2 Cover Plate: Stainless Steel, ASTM A 666, alloy 304; Mill finish.2.2.1.7.2.3 Extruded Center Plate: Aluminum, ASTM B 221, alloy 6063-T5;

Mill finish.2.2.1.7.2.4 Center Plate: Aluminum ASTM B 209, alloy 5052-H32; Mill finish.2.2.1.7.2.5 Center Plate: Stainless Steel, ASTM A 666, alloy 304; Mill finish.

2.2.1.7.3 Model: HPG - Elastomeric pads and a metal center plate which spans the joint.

2.2.1.7.3.1 Center Plate: Steel, ASTM A 36, Hot Rolled Carbon Steel, Hot-Dipped Galvanized.

2.2.1.7.3.2 Center Plate: Stainless Steel, ASTM A 666, alloy 304; Mill finish.2.2.1.7.3.3 Neoprene pad: 3/8 inch (9.5 mm) thick, fiber reinforced, UV

resistant, 2 ply, belt pad; Black Finish.2.2.1.7.3.4 Nosing: ASTM D 4020 UHMW Polyethylene; Black Finish.

2.2.1.7.4 Allowable movement: As specified for each floor or plane on the Contract Drawings.

07 95 00-6

Page 7: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.1.7.5 Allowable Uniform Load: 50 psf.2.2.1.7.6 Allowable Uniform Load: 100 psf.2.2.1.7.7 Allowable Uniform Load: 200 psf.2.2.1.7.8 Concentrated Load: 300 pounds (136 kg).2.2.1.7.9 Concentrated Load: 2,000 pounds (907 kg).2.2.1.7.10 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.1.7.11 Deflection: 1/8 inch (3 mm) at neutral position.

2.2.1.8 Balco DuraFlex NW Series: No Wing Seal System: Watertight deck expansion control system capable of accommodating multi-directional movement. Consists of an extruded elastomeric compression seal secured to the deck with adhesive. Sized to accommodate the total range of movement.

2.2.1.8.1 Seal Material: Santoprene.2.2.1.8.1.1 Hardness, Type A Durometer, ASTM D 2240: 64 plus or minus 3.2.2.1.8.1.2 Specific Gravity, ASTM D 297: 0.97 plus or minus 2.2.2.1.8.1.3 Tensile strength, minimum, ASTM D 412: 1000 psi (Mpa).2.2.1.8.1.4 Ultimate elongation, minimum, ASTM D 412: 400 percent.2.2.1.8.1.5 Brittle point, ASTM D 746: minus 76 degrees F.2.2.1.8.1.6 High Temp Recovery (70 hours at 212 degrees F): 82 percent.

2.2.1.9 Balco DuraFlex RB Series Heavy Duty Rubber Block System: Watertight deck expansion control system capable of accommodating multi-directional movement. Elastomeric membrane is secured using anchor blocks and sized to accommodate the total range of movement.

2.2.1.9.1 Seal Material: Santoprene.2.2.1.9.1.1 Tensile strength, minimum, ASTM D 412: 1050 psi (Mpa).2.2.1.9.1.2 Ultimate elongation, minimum, ASTM D 412: 410 percent.2.2.1.9.1.3 Hardness, Type A Durometer, ASTM D 2240 mod.: 67 +/- 3.2.2.1.9.1.4 Compression Set, 77 degrees F, ASTM D 395, Method B (mod.):

23.2.2.1.9.1.5 Compression Set, 168 hrs, 212 degrees F, ASTM D 395, Method

B (mod.): 36 percent.2.2.1.9.1.6 100 percent modulus, ASTM D 412: 420 psi.2.2.1.9.1.7 Tear strength, ASTM D 624: 140 lbs/inch.2.2.1.9.1.8 Tension set, ASTM D 412: 10 percent.2.2.1.9.1.9 Brittle point, ASTM D 746: minus 81 degrees F (minus 63 degrees

C).2.2.1.9.2 Finish: Black.2.2.1.9.3 Anchor Blocks: Steel-reinforced EPDM segmental pads with a non-slip

surface pattern and integral bolt cavities for fastening the system to the deck. Meets or exceeds requirements of ASTM D 2000.

2.2.1.9.3.1 Tensile strength, ASTM D 412: 1500 psi.2.2.1.9.3.2 Elongation at break, ASTM D 412: 350 percent.2.2.1.9.3.3 Hardness, Type A Durometer, ASTM D 412: 60.2.2.1.9.3.4 Low Temperature Flexibility, ASTM D 2137 Method A, minus 40

degrees F (minus 40 degrees C) at 40 degrees F (4 degrees C): Pass.

2.2.1.9.3.5 Heat Aged 70 Hours, ASTM D 573-67 at 212 degrees F (100 degrees C) Hardness: Pass.

2.2.1.9.3.6 Oil Deterioration, ASTM D 471: Pass.2.2.1.9.3.7 Ozone Resistance, ASTM D 1149, (No Cracks): Pass.2.2.1.9.3.8 Ultraviolet Resistance, ASTM D 2137 Method A, 1000 hrs: No

change in appearance.2.2.1.10 Balco DuraFlex SPS Series Single-Ply Membrane System: Watertight seal deck

expansion control system capable of accommodating multi-directional movement. Elastomeric single-ply membrane is secured to the deck using an elastomeric concrete nosing material and sized to accommodate the total range of movement.

07 95 00-7

Page 8: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.1.10.1 Seal Material: Santoprene.2.2.1.10.1.1 Tensile strength, minimum, ASTM D 412: 1000 psi (Mpa).2.2.1.10.1.2 Ultimate elongation, minimum, ASTM D 412: 410 percent.2.2.1.10.1.3 Hardness, Type A Durometer, ASTM D 2240 mod.: 67 plus or

minus 3.2.2.1.10.1.4 Compression Set, 77 degrees F, ASTM D 395, Method B (mod.):

24.2.2.1.10.1.5 Compression Set, 168 hrs, 212 degrees F, ASTM D 395, Method

B (mod.): 36 percent.2.2.1.10.1.6 100 percent modulus, ASTM D 412: 420 psi.2.2.1.10.1.7 Tear strength, ASTM D 624: 140 lbs/inch.2.2.1.10.1.8 Tension set, ASTM D 412: 10 percent.2.2.1.10.1.9 Specific gravity, ASTM D 792: 0.97.2.2.1.10.1.10 Brittle point, ASTM D 746: minus 81 degrees F (minus 63

degrees C).2.2.1.10.2 Finish: Black.

2.2.1.11 Balco DuraFlex SR Series Steel Rail System: Watertight deck expansion control system capable of accommodating HS20 loads and accommodating multi-directional movement. Steel rails with formed anchor bars and channels engage an extruded elastomeric seal. Secured to the deck using a proprietary ambient-cured elastomeric concrete nosing material.

2.2.1.11.1 Seal Tensile strength, minimum, ASTM D 412: 1700 psi (Mpa).2.2.1.11.2 Seal Ultimate elongation, minimum, ASTM D 412: 225.2.2.1.11.3 Seal Hardness, Type A Durometer, ASTM D 2240: 65 plus or minus 5.2.2.1.11.4 Seal Tear strength, minimum, ASTM D 624: 125 lb./in.2.2.1.11.5 Seal Compression set, 22h @ 212F maximum, ASTM D 395: 30 percent.2.2.1.11.6 Seal Heat aging, 70h at 212 degrees F, ASTM D 573.

2.2.1.11.6.1 Hardness increase, maximum durometer: 10.2.2.1.11.6.2 Change in tensile, maximum: 15 percent.2.2.1.11.6.3 Change in elongation, maximum: 40 percent.

2.2.1.11.7 Seal Ozone resistance, 100h at 104 degrees F, ASTM D 1149: No cracks.2.2.1.11.8 Steel Rail: ASTM A36 Steel (shapes) or ASTM A 588 Steel (extrusions).2.2.1.11.9 Steel Stud Anchors: 0.5 inches (13 mm) by 9 inches (229 mm) bent 90

degrees at 3 inches (76 mm).2.2.1.12 Balco DuraFlex SCPQ Series Heavy Duty Parking Garage System: Extruded

aluminum subchannels and a metal center plate which spans the joint. Water barrier bridges the joint while 75 mil thick EPDM pads cushion the center plate.

2.2.1.12.1 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill finish.2.2.1.12.2 Center Plate: Aluminum ASTM B 209, alloy 5052-H32; Mill finish.2.2.1.12.3 Pad Material: EPDM; Black finish.

2.2.2 Metal Expansion Control Systems2.2.2.1 Balco 6000 Series:

2.2.2.1.1 Type: 6FS, Floor to Floor Cover.2.2.2.1.2 Type: 6FVS, Floor to Wall Cover.2.2.2.1.3 Type: 6FTP, Floor to Floor Cover.2.2.2.1.4 Type: 6FVTP, Floor to Wall Cover.2.2.2.1.5 Type: 6FVSE, Floor to Floor Cover. For existing.2.2.2.1.6 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.2.2.2.1.7 Cover Plate: Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.2.1.8 Cover Plate: ASTM A 666 Type 304 Stainless Steel; Matte Finish, Sanded.2.2.2.1.9 Cover Plate: Bronze.2.2.2.1.10 Surface: Plain.2.2.2.1.11 Surface: Carpet.2.2.2.1.12 Surface: Abrasive.2.2.2.1.13 Allowable movement: As specified for each floor or plane on the Drawings.

07 95 00-8

Page 9: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.2.1.14 Allowable Uniform Load: 50 psf.2.2.2.1.15 Allowable Uniform Load: 100 psf.2.2.2.1.16 Allowable Uniform Load: 200 psf.2.2.2.1.17 Allowable Uniform Load: ___ psf.2.2.2.1.18 Concentrated Load: 300 pounds (136 kg).2.2.2.1.19 Concentrated Load: 2,000 pounds (907 kg).2.2.2.1.20 Concentrated Load: ___ pounds (___ kg).2.2.2.1.21 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.1.22 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.1.23 Deflection: __ inch (__ mm) at neutral position.

2.2.2.2 Balco All Aluminum Floor Covers:2.2.2.2.1 Type: RDA, Floor to Floor Cover.2.2.2.2.2 Type: RDAL, Floor to Wall Cover.2.2.2.2.3 Type: DA, Floor to Floor Cover.2.2.2.2.4 Type: DLA, Floor to Wall Cover.2.2.2.2.5 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.2.2.2.2.6 Cover Plate: Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.2.2.7 Cover Plate: ASTM A 666 Type 304 Stainless Steel; Matte Finish, Sanded.2.2.2.2.8 Cover Plate: Bronze.2.2.2.2.9 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.2.10 Allowable Uniform Load: 50 psf.2.2.2.2.11 Allowable Uniform Load: 100 psf.2.2.2.2.12 Allowable Uniform Load: 200 psf.2.2.2.2.13 Allowable Uniform Load: ___ psf.2.2.2.2.14 Concentrated Load: 300 pounds (136 kg).2.2.2.2.15 Concentrated Load: 2,000 pounds (907 kg).2.2.2.2.16 Concentrated Load: ___ pounds (___ kg).2.2.2.2.17 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.2.18 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.2.19 Deflection: __ inch (__ mm) at neutral position.

2.2.2.3 Balco No Bump Floor Covers:2.2.2.3.1 Type: NBA, Floor to Floor Cover.2.2.2.3.2 Type: NBAL, Floor to Wall Cover.2.2.2.3.3 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.2.3.4 Center Plate with Centering Bar: Aluminum, ASTM B 221, alloy 6063-T5;

Mill Finish.2.2.2.3.5 Center Plate with Centering Bar: ASTM A 666 Type 304 Stainless Steel;

Matte Finish.2.2.2.3.6 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.3.7 Allowable Uniform Load: 50 psf.2.2.2.3.8 Allowable Uniform Load: 100 psf.2.2.2.3.9 Allowable Uniform Load: 200 psf.2.2.2.3.10 Allowable Uniform Load: ___ psf.2.2.2.3.11 Concentrated Load: 300 pounds (136 kg).2.2.2.3.12 Concentrated Load: 2,000 pounds (907 kg).2.2.2.3.13 Concentrated Load: ___ pounds (___ kg).2.2.2.3.14 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.3.15 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.3.16 Deflection: __ inch (__ mm) at neutral position.

2.2.2.4 Balco 9500 Dual Elastomeric Floor Covers:2.2.2.4.1 Type: 95FV, Floor to Floor Dual Joint Cover.2.2.2.4.2 Type: 95FVT, Floor to Wall Dual Joint Cover.2.2.2.4.3 Type: 95GFP, Floor to Floor Dual Joint Cover. For Existing.2.2.2.4.4 Type: 95GFVP, Floor to Wall Dual Joint Cover. For Existing.2.2.2.4.5 Insert: Extruded Santoprene.

2.2.2.4.5.1 Color: Black.

07 95 00-9

Page 10: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.2.4.5.2 Color: Tan.2.2.2.4.5.3 Color: Gray.

2.2.2.4.6 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.2.4.7 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.4.8 Allowable Uniform Load: 50 psf.2.2.2.4.9 Allowable Uniform Load: 100 psf.2.2.2.4.10 Allowable Uniform Load: 200 psf.2.2.2.4.11 Allowable Uniform Load: ___ psf.2.2.2.4.12 Concentrated Load: 300 pounds (136 kg).2.2.2.4.13 Concentrated Load: 2,000 pounds (907 kg).2.2.2.4.14 Concentrated Load: ___ pounds (___ kg).2.2.2.4.15 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.4.16 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.4.17 Deflection: __ inch (__ mm) at neutral position.

2.2.2.5 Balco 7500 Elastomeric Floor Covers:2.2.2.5.1 Type: 75FVP, Floor to Wall Cover. Flush Mounted.2.2.2.5.2 Type: 75FVPE, Floor to Wall Cover. Surface Mounted.2.2.2.5.3 Type: 75FP, Floor to Floor Cover. Flush Mounted.2.2.2.5.4 Type: 75FPE, Floor to Floor Cover. Surface Mounted.2.2.2.5.5 Insert: Extruded Santoprene.

2.2.2.5.5.1 Color: Black.2.2.2.5.5.2 Color: Tan.2.2.2.5.5.3 Color: Gray.

2.2.2.5.6 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.2.5.7 Surface: Plain.2.2.2.5.8 Surface: Carpet.2.2.2.5.9 Surface: 1/8 inch (3 mm) tile.

2.2.2.6 Balco Gymnasium Floor Covers:2.2.2.6.1 Type: 1100/1400 Surface Mounted.2.2.2.6.2 Type: 1120/1420 Surface Mounted.2.2.2.6.3 Type: GFE-1D Recessed to Surface Mount.2.2.2.6.4 Type: GF-1S Surface Mounted.2.2.2.6.5 Type: GC Surface Mount Floor to Wall.2.2.2.6.6 Insert: Vinyl.

2.2.2.6.6.1 Color: Black.2.2.2.6.6.2 Color: Gray.

2.2.2.6.7 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.2.2.2.6.8 Center Plate: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.2.6.9 Center Plate Surfacing: Plain Plate.2.2.2.6.10 Center Plate Surfacing: Serrated Plate.2.2.2.6.11 Center Plate Surfacing: Abrasive Striped Plate.2.2.2.6.12 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.6.13 Allowable Uniform Load: 50 psf.2.2.2.6.14 Allowable Uniform Load: 100 psf.2.2.2.6.15 Allowable Uniform Load: 200 psf.2.2.2.6.16 Allowable Uniform Load: ___ psf.2.2.2.6.17 Concentrated Load: 300 pounds (136 kg).2.2.2.6.18 Concentrated Load: 2,000 pounds (907 kg).2.2.2.6.19 Concentrated Load: ___ pounds (___ kg).2.2.2.6.20 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.6.21 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.6.22 Deflection: __ inch (__ mm) at neutral position.

2.2.2.7 Balco Existing to Existing / New to Existing Floor Covers:2.2.2.7.1 Type: EXB Floor to Floor Cover.2.2.2.7.2 Type: EXBL Floor to Wall Cover.2.2.2.7.3 Center Plate with Centering Bar: Aluminum, ASTM B 221, alloy 6063-T5;

07 95 00-10

Page 11: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

Mill Finish.2.2.2.7.4 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.7.5 Allowable Uniform Load: 50 psf.2.2.2.7.6 Allowable Uniform Load: 100 psf.2.2.2.7.7 Allowable Uniform Load: 200 psf.2.2.2.7.8 Allowable Uniform Load: ___ psf.2.2.2.7.9 Concentrated Load: 300 pounds (136 kg).2.2.2.7.10 Concentrated Load: 2,000 pounds (907 kg).2.2.2.7.11 Concentrated Load: ___ pounds (___ kg).2.2.2.7.12 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.7.13 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.7.14 Deflection: __ inch (__ mm) at neutral position.

2.2.2.8 Balco Sight Line Covers:2.2.2.8.1 Type: CR Floor to Floor Cover.2.2.2.8.2 Type: CRL Floor to Wall Cover.2.2.2.8.3 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.2.2.2.8.4 Concealed Center Plate: ASTM A 666 Type 304 Stainless Steel; Matte

Finish, Sanded.2.2.2.8.5 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.8.6 Allowable Uniform Load: 50 psf.2.2.2.8.7 Allowable Uniform Load: 100 psf.2.2.2.8.8 Allowable Uniform Load: 200 psf.2.2.2.8.9 Allowable Uniform Load: ___ psf.2.2.2.8.10 Concentrated Load: 300 pounds (136 kg).2.2.2.8.11 Concentrated Load: 2,000 pounds (907 kg).2.2.2.8.12 Concentrated Load: ___ pounds (___ kg).2.2.2.8.13 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.8.14 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.8.15 Deflection: __ inch (__ mm) at neutral position.

2.2.2.9 Balco Topping Slab Floor Covers:2.2.2.9.1 Type: SAA Floor to Floor Cover.2.2.2.9.2 Type: SLA Floor to Wall Cover.2.2.2.9.3 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.2.2.2.9.4 Cover Plate: Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.2.9.5 Cover Plate: ASTM A 666 Type 304 Stainless Steel; Matte Finish, Sanded.2.2.2.9.6 Cover Plate: Bronze.2.2.2.9.7 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.9.8 Allowable Uniform Load: 50 psf.2.2.2.9.9 Allowable Uniform Load: 100 psf.2.2.2.9.10 Allowable Uniform Load: 200 psf.2.2.2.9.11 Allowable Uniform Load: ___ psf.2.2.2.9.12 Concentrated Load: 300 pounds (136 kg).2.2.2.9.13 Concentrated Load: 2,000 pounds (907 kg).2.2.2.9.14 Concentrated Load: ___ pounds (___ kg).2.2.2.9.15 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.9.16 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.9.17 Deflection: __ inch (__ mm) at neutral position.

2.2.2.10 Balco Aluminum Cover with Elastomeric Insert:2.2.2.10.1 Type: D/DT Floor to Floor Cover.2.2.2.10.2 Type: DL/DLT Floor to Wall Cover.2.2.2.10.3 Insert: Vinyl.

2.2.2.10.3.1 Color: Black.2.2.2.10.3.2 Color: Gray.

2.2.2.10.4 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.2.2.2.10.5 Center Plate with Centering Bar: Aluminum, ASTM B 221, alloy 6063-T5;

Mill Finish.

07 95 00-11

Page 12: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.2.10.6 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.10.7 Allowable Uniform Load: 50 psf.2.2.2.10.8 Allowable Uniform Load: 100 psf.2.2.2.10.9 Allowable Uniform Load: 200 psf.2.2.2.10.10 Allowable Uniform Load: ___ psf.2.2.2.10.11 Concentrated Load: 300 pounds (136 kg).2.2.2.10.12 Concentrated Load: 2,000 pounds (907 kg).2.2.2.10.13 Concentrated Load: ___ pounds (___ kg).2.2.2.10.14 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.10.15 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.10.16 Deflection: __ inch (__ mm) at neutral position.

2.2.2.11 Balco PS Series Seismic Floor Covers:2.2.2.11.1 Type: PS Floor to Floor Cover.2.2.2.11.2 Type: PSL Floor to Wall Cover.2.2.2.11.3 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.2.2.2.11.4 Base Members: Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.2.11.5 Pan with Centering Bar and Spring: Aluminum, ASTM B 221, alloy 6063-

T5; Mill Finish.2.2.2.11.6 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.11.7 Allowable Uniform Load: 50 psf.2.2.2.11.8 Allowable Uniform Load: 100 psf.2.2.2.11.9 Allowable Uniform Load: 200 psf.2.2.2.11.10 Allowable Uniform Load: ___ psf.2.2.2.11.11 Concentrated Load: 300 pounds (136 kg).2.2.2.11.12 Concentrated Load: 2,000 pounds (907 kg).2.2.2.11.13 Concentrated Load: ___ pounds (___ kg).2.2.2.11.14 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.11.15 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.11.16 Deflection: __ inch (__ mm) at neutral position.

2.2.2.12 Balco Heavy Duty Floor Covers:2.2.2.12.1 Type: XH4FS Floor to Floor Cover for Topping Slab.2.2.2.12.2 Type: XH4FVS Floor to Wall Cover, New to Existing.2.2.2.12.3 Type: HDEW Floor to Floor Cover with Extra Wide Blockout.2.2.2.12.4 Type: HDEWL Floor to Wall Cover; Extra Wide Blockout, New to Existing.2.2.2.12.5 Type: ATS Floor to Floor Cover for Air Terminal.2.2.2.12.6 Type: ATSL Floor to Wall Cover for Air Terminal, New to Existing.2.2.2.12.7 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.2.2.2.12.8 Center Plate with Centering Bar: Aluminum, ASTM B 221, alloy 6063-T5;

Mill Finish.2.2.2.12.9 Mounting Bar: Carbon Steel Angle.2.2.2.12.10 Allowable movement: As specified for each floor or plane on the

Drawings.2.2.2.12.11 Allowable Uniform Load: 50 psf.2.2.2.12.12 Allowable Uniform Load: 100 psf.2.2.2.12.13 Allowable Uniform Load: 200 psf.2.2.2.12.14 Allowable Uniform Load: ___ psf.2.2.2.12.15 Concentrated Load: 300 pounds (136 kg).2.2.2.12.16 Concentrated Load: 2,000 pounds (907 kg).2.2.2.12.17 Concentrated Load: ___ pounds (___ kg).2.2.2.12.18 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.12.19 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.12.20 Deflection: __ inch (__ mm) at neutral position.

2.2.2.13 Balco Extra Heavy Duty Floor Covers:2.2.2.13.1 Type: XH4FS Flush Mounted Floor to Floor Cover.2.2.2.13.2 Type: XH4FVS Flush Mounted Floor to Wall Cover.2.2.2.13.3 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.

07 95 00-12

Page 13: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.2.13.4 Cover Plate: Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.2.13.5 Cover Plate: ASTM A 666 Type 304 Stainless Steel; Matte Finish, Sanded.2.2.2.13.6 Cover Plate: Bronze.2.2.2.13.7 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.13.8 Allowable Uniform Load: 50 psf.2.2.2.13.9 Allowable Uniform Load: 100 psf.2.2.2.13.10 Allowable Uniform Load: 200 psf.2.2.2.13.11 Allowable Uniform Load: ___ psf.2.2.2.13.12 Concentrated Load: 300 pounds (136 kg).2.2.2.13.13 Concentrated Load: 2,000 pounds (907 kg).2.2.2.13.14 Concentrated Load: ___ pounds (___ kg).2.2.2.13.15 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.13.16 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.13.17 Deflection: __ inch (__ mm) at neutral position.

2.2.2.14 Balco Extra Wide Seismic Floor Covers:2.2.2.14.1 Type: 6FTP Flush Mounted Floor to Floor Cover.2.2.2.14.2 Type: 9FP Flush Mounted Floor to Floor Cover.2.2.2.14.3 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill finish.2.2.2.14.4 Cover Plate: Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.2.14.5 Allowable movement: As specified for each floor or plane on the Drawings.2.2.2.14.6 Allowable Uniform Load: 50 psf.2.2.2.14.7 Allowable Uniform Load: 100 psf.2.2.2.14.8 Allowable Uniform Load: 200 psf.2.2.2.14.9 Allowable Uniform Load: ___ psf.2.2.2.14.10 Concentrated Load: 300 pounds (136 kg).2.2.2.14.11 Concentrated Load: 2,000 pounds (907 kg).2.2.2.14.12 Concentrated Load: ___ pounds (___ kg).2.2.2.14.13 Deflection: 1/16 inch (1.5 mm) at neutral position.2.2.2.14.14 Deflection: 1/8 inch (3 mm) at neutral position.2.2.2.14.15 Deflection: __ inch (__ mm) at neutral position.

2.2.3 Wall And Ceiling Covers2.2.3.1 Balco Flexible Interior Wall and Ceiling Covers:

2.2.3.1.1 Type: GCWW Wall Joint Cover.2.2.3.1.2 Type: GCVSC 90 Degree Wall Corner Cover.2.2.3.1.3 Insert: Extruded Santoprene.

2.2.3.1.3.1 Color: White.2.2.3.1.3.2 Color: Black.2.2.3.1.3.3 Color: Tan.2.2.3.1.3.4 Color: Gray.

2.2.3.1.4 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.3.2 Balco Clip-In Wall and Ceiling Covers:

2.2.3.2.1 Type: 1W1 Wall Joint Cover.2.2.3.2.2 Type: 1C1 90 Degree Wall Corner Cover.2.2.3.2.3 Type: C1W1 Single Plane Ceiling Cover.2.2.3.2.4 Type: C1C1 90 Degree Ceiling Corner Cover.2.2.3.2.5 Clips: Spring Steel.2.2.3.2.6 Cover Plate: Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.

2.2.3.3 Balco Snap-On Wall and Ceiling Covers:2.2.3.3.1 Type: WD Wall Joint Cover.2.2.3.3.2 Type: WDC 90 Degree Corner Cover.2.2.3.3.3 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.2.2.3.3.4 Cover Plate: Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.3.3.5 Cover Plate: ASTM A 666 Type 304 Stainless Steel; Matte Finish, Sanded.2.2.3.3.6 Cover Plate: Bronze.

2.2.3.4 Balco Vinylines Wall and Ceiling Covers:

07 95 00-13

Page 14: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.3.4.1 Type: AC Ceiling to Ceiling Joint Cover.2.2.3.4.2 Type: ACL Ceiling to Wall Joint Cover.2.2.3.4.3 Type: GP Flush Mounted to Flush Mounted Wall Cover.2.2.3.4.4 Type: GPL Flush Mounted to Flush Mounted Corner Cover.2.2.3.4.5 Type: GM Raised Mount to Raised Mounted Wall Cover.2.2.3.4.6 Type: GML Raised Mount to Raised Mounted Corner Cover.2.2.3.4.7 Insert: Extruded Santoprene.

2.2.3.4.7.1 Color: White.2.2.3.4.7.2 Color: Black.2.2.3.4.7.3 Color: Tan.2.2.3.4.7.4 Color: Gray.

2.2.3.4.8 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.3.5 Balco Extra Wide Seismic Interior Wall and Ceiling Covers:

2.2.3.5.1 Type: CM Wall Joint Cover.2.2.3.5.2 Type: CML 90 Degree Corner Cover- Flush Mount to Surface Mount.2.2.3.5.3 Insert: Extruded Santoprene.2.2.3.5.4 Color: White.2.2.3.5.5 Color: Black.2.2.3.5.6 Color: Tan.2.2.3.5.7 Color: Gray.2.2.3.5.8 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.3.5.9 Cover Plate: Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.

2.2.3.6 Balco 9500 Dual Elastomeric Interior Wall and Ceiling Covers:2.2.3.6.1 Type: 95GW Wall Joint Cover.2.2.3.6.2 Type: 95GWC 90 Degree Corner Cover, Flush Mount to Surface Mount.2.2.3.6.3 Insert: Extruded Santoprene.

2.2.3.6.3.1 Color: White.2.2.3.6.3.2 Color: Black.2.2.3.6.3.3 Color: Tan.2.2.3.6.3.4 Color: Gray.

2.2.3.6.4 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.2.2.3.7 Balco 7500 Elastomeric Interior Wall and Ceiling Covers:

2.2.3.7.1 Type: 75FWG Wall Joint Cover.2.2.3.7.2 Type: 75FWGC 90 Degree Corner Cover.2.2.3.7.3 Insert: Extruded Santoprene.

2.2.3.7.3.1 Color: White.2.2.3.7.3.2 Color: Black.2.2.3.7.3.3 Color: Tan.2.2.3.7.3.4 Color: Gray.

2.2.3.7.4 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Anodized.2.2.3.8 Balco 6000 Series Interior Wall and Ceiling Covers:

2.2.3.8.1 Type: 6GW Flush Mounted Wall Cover.2.2.3.8.2 Type: 6TW Raised Mount Wall Cover.2.2.3.8.3 Type: 6GWFC Surface Mounted to Flush Mounted Corner Cover.2.2.3.8.4 Type: 6GWC Flush Mounted to Flush Mounted Corner Cover.2.2.3.8.5 Type: 6TWFC Surface Mounted to Raised Mount Corner Cover.2.2.3.8.6 Type: 6TWC Raised Mount to Raised Mount Corner Cover.2.2.3.8.7 Center Plate: Aluminum ASTM B 209 Alloy 5052-H32; Mill Finish.2.2.3.8.8 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill Finish.

2.2.3.9 Balco Interior Flat / Variable Seal:2.2.3.9.1 Type: FCWW Wall Joint Cover.2.2.3.9.2 Type: FCWWE 90 Degree Corner Cover.2.2.3.9.3 Primary Seal: Extruded Santoprene.2.2.3.9.4 Primary Seal: Silicone.2.2.3.9.5 Seal Color: White.2.2.3.9.6 Seal Color: Black.

07 95 00-14

Page 15: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.3.9.7 Seal Color: Tan.2.2.3.9.8 Seal Color: Gray.2.2.3.9.9 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill finish.

2.2.4 Exterior Seals And Covers2.2.4.1 Balco Exterior Flat / Variable Seal:

2.2.4.1.1 Type: FCWW Wall Joint Cover.2.2.4.1.2 Type: FCWWE 90 Degree Corner Cover.2.2.4.1.3 Primary Seal: Extruded Santoprene.2.2.4.1.4 Primary Seal: Silicone.2.2.4.1.5 Seal Color: White.2.2.4.1.6 Seal Color: Black.2.2.4.1.7 Seal Color: Tan.2.2.4.1.8 Seal Color: Gray.2.2.4.1.9 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill finish.2.2.4.1.10 Secondary Seal: Santoprene; Black Finish.

2.2.4.2 Balco Exterior Wall Covers:2.2.4.2.1 Type: 9W Wall Joint Cover.2.2.4.2.2 Type: 9WC 90 Degree Corner Cover.2.2.4.2.3 EPDM Water Barrier.2.2.4.2.4 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill finish.2.2.4.2.5 Cover Plate: ASTM B 209 Alloy 5052-H32 Aluminum; Mill Finish.2.2.4.2.6 Cover Plate: ASTM A 666 Type 304 Stainless Steel; Matte Finish, Sanded.

2.2.4.3 Balco Aluminum Roof Covers:2.2.4.3.1 Type: LPR Roof to Roof.2.2.4.3.2 Type: FR Curb to Curb.2.2.4.3.3 Type: LPRE Roof to Wall.2.2.4.3.4 Type: FRE Curb to Wall.2.2.4.3.5 EPDM Water Barrier.2.2.4.3.6 Subchannel: Extruded Aluminum, ASTM B 221, alloy 6063-T5; Mill finish.2.2.4.3.7 Cover Plate: ASTM B 209 Alloy 5052-H32 Aluminum; Mill Finish.2.2.4.3.8 Cover Plate: ASTM A 666 Type 304 Stainless Steel; Matte Finish, Sanded.

2.2.4.4 Balco Roof Bellows:2.2.4.4.1 Type: Straight Flange Roof to Wall.2.2.4.4.2 Type: Straight Flange Roof to Roof.2.2.4.4.3 Type: Curb Flange Roof to Wall.2.2.4.4.4 Type: Curb Flange Roof to Roof.2.2.4.4.5 Bellows Material: EPDM; Black Finish.2.2.4.4.6 Bellows Material: Neoprene; Black Finish.2.2.4.4.7 Flange Material: Galvanized Steel, 26 gauge.2.2.4.4.8 Flange Material: Aluminum.2.2.4.4.9 Flange Material: Copper.2.2.4.4.10 Flange Material: Stainless Steel.

2.2.5 Associated Materials2.2.5.1 Elastomeric Concrete: Ambient-cured header material consisting of polyurethane

liquid components "A" and "B" and a proprietary aggregate system. Site mixed to achieve the following physical properties:

2.2.5.1.1 Color: Black.2.2.5.1.2 Tensile strength; ASTM D 412: 1680 psi.2.2.5.1.3 Elongation at break, minimum, ASTM D 638: 240 percent.2.2.5.1.4 Durometer hardness, Type A, ASTM D 2240: 75 plus or minus 3.2.2.5.1.5 Tear resistance, minimum, ASTM D 624: 195 lbs/inch.2.2.5.1.6 Adhesion Properties Bond to Concrete, minimum, ASTM C109: 422 psi.2.2.5.1.7 Pot life, minimum: 20 minutes.2.2.5.1.8 Ozone Resistance - ASTM D 1149: No Cracks.

07 95 00-15

Page 16: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.2.5.1.9 UV Resistance, ASTM G 53: Excellent.2.2.5.1.10 Compression Strength, ASTM D 695.

2.2.5.1.10.1 5 percent deflection, minimum: 1442 psi.2.2.5.1.10.2 Resilience, minimum: 96 percent.

2.2.5.2 Bonding Agent:2.2.5.2.1 Primer 2: Two component primer.2.2.5.2.2 Tack Coat: TC12 two component bedding material.

2.2.5.3 Adhesive: Site mixed two-component, epoxy-based adhesive with the following physical properties:

2.2.5.3.1 Adhesive Type: Two component thixotropic paste.2.2.5.3.2 Tensile strength: 4000 psi.2.2.5.3.3 Pot life: 60 minutes at 68 degrees F (20 degrees C).2.2.5.3.4 Flash point: Above 200 degrees F (93 degrees C).2.2.5.3.5 Non-volatile content:

2.2.5.3.5.1 Part A, 100 percent reactive.2.2.5.3.5.2 Part B, 99.9 percent reactive.

2.2.5.3.6 Initial Curing Time: 24 hours.2.2.5.3.7 Complete Cure: 7 days at 68 degrees F (20 degrees C).

2.2.5.4 Lubricant Adhesive: Single component, polyurethane and hydrocarbon solvent mixture complying with ASTM D 4070 and having the following physical properties:

2.2.5.4.1 Tensile Strength: ASTM D 412, 250 psi.2.2.5.4.2 Adhesion-in-Peel: ASTM C 794, 20 lbs.2.2.5.4.3 Ultimate Elongation: ASTM E 412, 800 percent.2.2.5.4.4 Hardness (Shore A): ASTM C 661, 25 plus or minus 5.2.2.5.4.5 Weight Loss: ASTM C 792, 8 percent maximum.2.2.5.4.6 Weep & Sag: ASTM C 639, None.2.2.5.4.7 Tack Free Time: ASTM C 679, 4 hours.

2.2.5.5 Fire Barrier: Membrane type fire barrier required for indicated joint size and fire resistance.

2.2.5.5.1 Type: Metaflex.2.2.5.5.2 Type: Metaflex 2000.2.2.5.5.3 Type: MetaMat2.2.5.5.4 Type: MetaBlock

2.2.5.6 Flame Sealant: Metacaulk 990; sealant permits joint movement and upon exposure to heat, increase in volume to resist penetration of fire through voids in construction.

2.2.5.7 Water Barrier: ASTM D 4637, EPDM sheet, flexible, 45 mils thick.2.2.5.8 Accessories:

2.2.5.8.1 Provide other materials as necessary to complete a proper Expansion Control System installation.

2.2.5.8.2 Architect must approve in writing all secondary materials to be used on the project.

2.3 MICHAEL RIZZO EXPANSION CONTROL ASSEMBLIES

2.3.1 Exterior Types:2.3.1.1 Michael Rizza Wall and Soffits: Aluminum retainers.

2.3.1.1.1 Michael Rizza EV Series (Silicone).2.3.1.1.1.1 Type EV-2, joint dimension 2 inches (51 mm), 1 rib, 4 inches (102

mm) tension back seal and 7/8 inch (22 mm) total compression.2.3.1.1.1.2 Type EV-3, joint dimension 3 inches (76 mm), 1 rib, 6 inches (152

mm) tension back seal and 1-7/8 inches (48 mm) total compression.

2.3.1.1.1.3 Type EV-4, joint dimension 4 inches (102 mm), 1 rib, 8 inches (203 mm) tension back seal and 2-7/8 inches (122 mm) total

07 95 00-16

Page 17: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

compression.2.3.1.1.1.4 Type EV-5, joint dimension 5 inches (127 mm), 1 rib, 10 Inches

(254 mm) tension back seal and 3-7/8 inches (96 mm) total compression.

2.3.1.1.1.5 Type EV-5-S, joint dimension 5 inches (127 mm), 1 rib, 10 inches (254 mm) tension back seal and 3-7/8 inches (96 mm) total compression.

2.3.1.1.1.6 Type EV-6, joint dimension 6 inches (152 mm), 1 rib, 12 inches (305 mm) tension back seal and 4-7/8 Inches (122 mm) total compression.

2.3.1.1.1.7 Type EV-7, joint dimension 7 inches (178 mm), 3 rib, 14 inches (355 mm) tension back seal and 5-7/8 inches (150 mm) total compression.

2.3.1.1.1.8 Type EV-8, joint dimension 8 inches (203 mm), 3 rib, 16 inches (406 mm) tension back seal and 6-7/8 inches (175 mm) total compression.

2.3.1.1.1.9 Type EV-9, joint dimension 9 inches (228 mm), 3 rib, 18 inches (457 mm) tension back seal and 7-7/8 inches (200 mm) total compression.

2.3.1.1.1.10 Type EV-10, joint dimension 10 inches (254 mm) 3 rib, 24 inches (610 mm) tension back seal and 8-7/8 inches (225 mm) total compression.

2.3.1.1.1.11 Type EV-11 (4GR), joint dimension 11 inches (280 mm), 3 rib, 24 inches (610 mm) tension back seal and 9-7/8 inches (250 mm) total compression.

2.3.1.1.1.12 Type EV-12 (4GR), joint dimension 12 inches (305 mm), 3 rib, 24 inches (610 mm) tension back seal and 10-7/8 inches (276 mm) total compression.

2.3.1.2 Michael Rizza Roof: Aluminum retainers.2.3.1.2.1 Michael Rizza RR Series (Roof to Roof - Silicone).

2.3.1.2.1.1 Type RR-2, joint dimension 2 inches (51 mm), height dimension 2-5/8 inches (66 mm).

2.3.1.2.1.2 Type RR-3, joint dimension 3 inches (76 mm), height dimension 3-5/8 Inches (90 mm).

2.3.1.2.1.3 Type RR-4, joint dimension 4 inches (102 mm), height dimension 4-5/8 inches (116 mm).

2.3.1.2.1.4 Type RR-5, joint dimension 5 inches (125 mm), height dimension 5-5/8 inches (143 mm).

2.3.1.2.1.5 Type RR-6, joint dimension 6 inches (152 mm), height dimension 6-5/8 inches (166 mm).

2.3.1.2.1.6 Type RR-7, joint dimension 7 inches (175 mm), height dimension 7-5/8 inches (194 mm).

2.3.1.2.1.7 Type RR-8, joint dimension 8 inches (203 mm), height dimension 8-5/8 inches (219 mm).

2.3.1.2.1.8 Type RR-9, joint dimension 9 inches (228 mm), height dimension 9-5/8 inches (244 mm).

2.3.1.2.1.9 Type RR-10, joint dimension 10 inches (254 mm), height dimension 10-5/8 inches (270 mm).

2.3.1.2.1.10 Type RR-11, joint dimension 11 inches (279 mm), height dimension 11-5/8 inches (295 mm).

2.3.1.2.1.11 Type RR-12, joint dimension 12 inches (305 mm), height dimension 12-5/8 inches (320 mm).

2.3.1.2.2 Michael Rizza RW Series (Roof to Wall - Silicone).2.3.1.2.2.1 Type RW-2, joint dimension 2 inches (51 mm), height dimension

2-5/8 inches (66 mm).2.3.1.2.2.2 Type RW-3, joint dimension 3 inches (76 mm), height dimension

07 95 00-17

Page 18: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

3-5/8 inches (90 mm).2.3.1.2.2.3 Type RW-4, joint dimension 4 inches (102 mm), height dimension

4-5/8 inches (116 mm).2.3.1.2.2.4 Type RW-5, joint dimension 5 inches (125 mm), height dimension

5-5/8 inches (143 mm).2.3.1.2.2.5 Type RW-6, joint dimension 6 inches (152 mm), height dimension

6-5/8 inches (166 mm).2.3.1.2.2.6 Type RW-7, joint dimension 7 inches (175 mm), height dimension

7-5/8 inches (194 mm).2.3.1.2.2.7 Type RW-8, joint dimension 8 inches (203 mm), height dimension

8-5/8 inches (219 mm)2.3.1.2.2.8 Type RW-9, joint dimension 9 inches (228 mm), height dimension

9-5/8 inches (244 mm)2.3.1.2.2.9 Type RW-10, joint dimension 10 inches (254 mm), height

dimension 10-5/8 inches (270 mm).2.3.1.2.2.10 Type RW-11, joint dimension 11 inches (279 mm), height

dimension 11-5/8 inches (295 mm).2.3.1.2.2.11 Type RW-12, joint dimension 12 inches (305 mm), height

dimension 12-5/8 inches (320 mm).

2.3.2 Michael Rizza Interior Types: Aluminum retainers.2.3.2.1 Walls and Ceilings:

2.3.2.1.1 Michael Rizza IS-Series (Silicone).2.3.2.1.1.1 Type IS-2, joint dimension 2 inches (51 mm), tension movement 4

inches (102 mm), total compression movement 1 inch (25 mm).2.3.2.1.1.2 Type IS-3, joint dimension 3 inches (76 mm), tension movement 5

inches (125 mm), total compression movement 2 inches (100 mm).

2.3.2.1.1.3 Type IS-4, joint dimension 4 inches (102 mm), tension movement 6inches (150 mm), total compression movement 3 inches (76 mm).

2.3.2.1.1.4 Type IS-5, joint dimension 5 inches (125 mm), tension movement 7-1/2 inches (190 mm), total compression movement 4 inches (102 mm).

2.3.2.1.1.5 Type IS-6, joint dimension 6 inches (152 mm), tension movement 9 inches (228 mm), total compression movement 5 inches (150 mm).

2.3.2.1.1.6 Type IS-7, joint dimension 7 inches (175 mm), tension movement 10-1/2 inches (266 mm), total compression movement 6 inches (152 mm).

2.3.2.1.1.7 Type IS-8, joint dimension 8 inches (203 mm), tension movement 12 inches (305 mm), total compression movement 7 inches (175 mm).

2.3.2.1.1.8 Type IS-9, joint dimension 9 Inches 225 m), tension movement 13-1/2 inches (330 mm), total compression movement 8 inches 203 mm).

2.3.2.1.1.9 Type IS-10, joint dimension 10 inches (250 mm), tension movement 15 inches (380 mm), total compression movement 9 inches (228 mm).

2.3.2.1.1.10 Type IS-11 (4GR), joint dimension 11 inches (275 mm), tension movement 16-1/2 inches (420 mm), total compression movement 10 inches (250 mm).

2.3.2.1.1.11 Type IS-12, joint dimension 12 inches (300 mm), tension movement 18 inches (458 mm), total compression movement 11 inches (280 mm).

07 95 00-18

Page 19: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

2.3.3 Michael Rizza Compression/Extension Seals2.3.3.1 Type CE-100SX: Joint dimension 1 inch (25 mm), compression minimum 0.375

inch (9.5 mm), extension maximum 2. inches (50 mm)2.3.3.2 Type CE-150SX: Joint dimension 1-1/2 inches (37 mm) compression minimum

0.563 inch (14.3 mm), extension maximum 2 -1/2 inches (63 mm).2.3.3.3 Type CE-200SX: Joint dimension 2 inches (51 mm) compression minimum 1

inch (25 mm), extension maximum 3.5 inches (88 mm).2.3.3.4 Type CE-300SX: Joint dimension 3 inches (76 mm) compression minimum 1.38

inches (35 mm), extension maximum 6 inches (152 mm).2.3.3.5 Type CE-400SX: Joint dimension 4 inches (102 mm) compression minimum

2.inches (50 mm), extension maximum 7 inches (175 mm).2.3.3.6 Type CE-500: Joint dimension 5 Inches (125 mm) compression minimum 3

inches (76 mm), extension maximum 9-1/2 inches (240 mm).2.3.3.7 Type SE-100-2: Joint dimension 1 (25 mm), compression minimum 0.375 inch

(9.5 mm), extension maximum 2 inches (51 mm).2.3.3.8 Type SE-200-4: Joint dimension 2 inches (51 mm), compression minimum 1/2

inch (12.5 mm), extension maximum 4 inches (102 mm).2.3.3.9 Type SE-200-4E: Joint dimension 2 inches (51 mm), compression minimum 3/4

inch (18 mm), extension maximum 4 inches (102 mm).2.3.3.10 Type 250-5E: Joint dimension 2-1/2 inches (64 mm), compression minimum 3/4

inch (18 mm), extension maximum 5 inches (125 mm).

2.3.4 Michael Rizza Fire Rated Types: (FRS)2.3.4.1 Incorporate fire and smoke barrier into assembly.2.3.4.2 Hourly rating as indicated on the Drawings.

2.3.5 Michael Rizza Special Details: Partition closures.2.3.5.1 PCN-1.2.3.5.2 PCN-2.2.3.5.3 PCS-1A.2.3.5.4 PCS-1B.2.3.5.5 PCS-1C.2.3.5.6 PCS-1D.2.3.5.7 PCS-1E.2.3.5.8 PCS-1F.

3 EXECUTION

3.1 EXAMINATION

3.1.1 Verify that field measurements and blockout dimensions are as shown on shop drawings prior to releasing materials for fabrication by the manufacturer.

3.1.2 Do not begin installation until substrates have been properly prepared.

3.1.3 If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

3.2 PREPARATION

3.2.1 Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3.2.2 Solidly form the blockout and joint opening, and allow concrete to properly cure. Corners must be sharp or rounded in accordance with the manufacturer's and project's requirements. Repair edges or areas with a concrete repair material approved by the Manufacturer and Architect.

07 95 00-19

Page 20: · Web viewASTM C 509 - Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material - Neoprene. ASTM C 864 - Standard Specification for Dense Elastomeric

3.2.3 Blockouts requiring the use of patching compounds must be cured in accordance with the patching compound manufacturer's recommendations and instructions prior to placement of Elastomeric Concrete. Coordinate with other trades if patching is the responsibility of others.

3.2.4 Clean dirt, debris, and other contaminants from the blockout and the joint opening.

3.2.5 Sandblast the blockout to expose aggregate to remove contaminants and prepare the surfaces for the installation of the Elastomeric Concrete Header material.

3.2.6 Mask areas adjacent to the joint with tape to assure neat, clean joint lines. Remove the tape prior to the curing process.

3.3 INSTALLATION

3.3.1 Install in accordance with manufacturer's instructions. Handle, mix or otherwise prepare all components in accordance with the manufacturer's recommendations and instructions.

3.3.2 Do not install Elastomeric Concrete when ambient temperature is below 40 degrees F.

3.3.3 Immediately prior to installation, blow out the blockout and joint interfaces using compressed air.

3.3.4 Prior to installation, remove packaging from elastomeric products and allow them to relax.

3.3.5 Clean up the work area after installation of the system is completed.

3.3.6 Fabricate horizontal transitions and butt splices such as 90 degree corners, tees and crosses as recommended by the manufacturer. Extend horizontal transitions a minimum of 24 inches (610 mm) in each direction from the splice.

3.3.7 Fabricate Wall Mount Plate of preformed 10 foot (3048 mm) 26 gauge stainless steel profiles cut to length on the jobsite, and miter cut where directional changes occur or are otherwise required.

3.4 PROTECTION

3.4.1 Protect the completed Expansion Control system work from damage during construction.

3.4.2 Do not allow vehicular traffic without the specific written permission of the Architect.

3.4.3 Prior to project closeout, clean exposed surfaces with a suitable cleaner (toluene or xylene) that will not harm the finish.

END OF SECTION

07 95 00-20