® DSE ULTRA  ® STARTING WITH QUALITY. SPECIFICATION ENVIRONMENT AL TESTING STANDARDS Th e DSE701 is av ailable in Ma nual and Aut o Sta rt ver sio ns, off erin g an exc el lent ra ng e of eng ine moni torin g and pro tecti on featur es. Th e mo du le has be en de sig ned to monitor low oil pr ess ure , high engine temper ature, oversp eed and a user -de fine d auxilia ry inp ut (manu al st ar t only ). When the mo du le de te cts a fau lt it wi ll auto matically shut dow n the engine. Th e mo du le al so has th e cap abil it y to monito r bat ter y char gin g by uti li si ng th e WL te rmin al on th e char ge alt ernat or . On det ect ing a fau lt , it will lig ht the wa rni ng LED on the fr on t pa ne l. Th e DS E7 02 is av ai lab le in Ma nua l and Aut o Sta rt ver sio ns incl udi ng all th e fea tu res of th e DS E7 01 pl us a tamper pr oof eng ine hour s counter.  Aut o sta rt vers ion s incl ude an opt ion for rem ote start sig nal inp ut . Th is inp ut al lo ws the mo dule to be st ar te d fr om a re mo te location. Bo th mo du le s are av ailabl e with or wit hou t key sta rt ope rati on (pl eas e sp ec ify ‘ke y’ or ‘NK’ on or de ri ng). FEATURES  Manual start or remote Start  Engine pre-heat  Engine monitoring and protection features  Protected solid state (PSS) outputs  Front panel mounting  Tamper proof engine hours counter (702 only)  LED indicators BENEFITS  Hours counter provides accurate information for monitoring maintenance and warranty periods (702 only)  Multiple engine parameters are monitored simultaneously OPERATION MAN UAL MOD E  The module is started using the on-board key/buttons  The user turn s the key to the position  The engine pre-heat button is then pressed for the required time  The start button is then pressed to start the engine  T o stop the engine the key needs to be turned to the off position  AU TO MATI C MO DE  Auto Star t version s  The key needs to be permanently le ft in th e po si ti on  The module is powered up by the remote start signal  The pre-heat function is automatically carried out and then the engine is started  T o stop the engine the remote switch is turned to the ‘off’ position OVERS PEED PROTE CTION  The engine over speed trip setting can be calibrated at the rear of the module for 50Hz or 60Hz nominal operation (57Hz or 68Hz trip respectively). ELECTR ICAL SAFETY BS EN 60950 Safety of Information Tec hnology Equipment, including Electrical Business Equipment ELECTR O MAGNE TIC COMP AT IBILIT Y BS EN 610 00- 6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 610 00- 6-4 EMC Generic Emission Standard for the Industrial Environment TEMPERATURE(OPERATING) BS EN 60068  Test Ab to +70 o C 60068-2-2 Hot  Test Ab to -30 o C 60068-2-1 Cold  VIB RA TI ON BS EN 60068-2-6  Ten sweeps i n each of three major axes 5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn HUMIDITY BS 2011 part 2.1 60068-2-30  Te st Cb Ob Cyclic 93% RH @ 40 o C for 48 hours SHOCK BS EN 60068-2-27  Three shocks in each of three major axes 15gn in 11mS IP RATING BS EN 60529 Degrees of protection provided by enclosures IP65 NK v ersio n only IP41 Wit h Key version only  Applies to Front of module when installed into the control panel with the supplied sealing gasket. DC SUPPL Y 8V to 35V continuous CRANKIN G DROPOU TS  Able to survive 0V for 50mS, providing supply was at least 10V before dropout and supply recovers to 5V. This is achieved without the need for internal batteries.  AL TERNA TOR INPUTFREQ UE NCY 50Hz – 60Hz at rated engine speed (minimum:15V Overspeed: nominal frequency +14% (+24% overshoot)  AL TE RNA TOR INPUTRANGE 15V-305V AC RMS (+20%) ST ART OUTPUT Solid state 1.2A negative grounding terminal RUNOUT PUT Solid state 1.2A negative grounding terminal PRE-HE ATOUTPUT Solid state 1.2A negative grounding terminal DSE701 DIMENS IONS 72mm x 72mm x 38mm 2.8” x 2.8” x 1.5” Excludes key switch DSE7 01 P ANE L CUTOUT 68mm x 68mm 2.7” x 2.7” DSE702 DIMENS IONS 84mm x 72mm x 34.9mm 3.3” x 2.8” x 1.4” Excludes key switch DSE7 02 P ANE L CUTOUT 80mm x 68mm 3.1” x 2.7” D S E701 & DSE702  AUTO & MA NUAL ST AR T CONT ROL MODULE S DSE701  DSE702

Dse 701 & Dse 702 Auto &Manual Start Control Modules

Embed Size (px)

DESCRIPTION

AUTO &MANUAL START CONTROL MODULES

Citation preview

Page 1: Dse 701 & Dse 702 Auto &Manual Start Control Modules

7/15/2019 Dse 701 & Dse 702 Auto &Manual Start Control Modules

http://slidepdf.com/reader/full/dse-701-dse-702-auto-manual-start-control-modules 1/2

®

DSEULTRA ®

STARTING

WITHQUALITY.SPECIFICATION

ENVIRONMENTAL TESTINGSTANDARDS

The DSE701 is available in Manual

and Auto Start versions, offering

an excellent range of engine

monitoring and protection features.

The module has been designed to

monitor low oil pressure, high

engine temperature, overspeed

and a user-defined auxiliary input

(manual start only). When the

module detects a fault it will

automatically shut down the

engine.

The module also has the capability 

to monitor battery charging by 

utilising the WL terminal on the

charge alternator. On detecting a

fault, it will light the warning LED

on the front panel.

The DSE702 is available in Manual

and Auto Start versions including

all the features of the DSE701 plus

a tamper proof engine hours

counter.

 Auto start versions include an

option for remote start signalinput. This input allows the module

to be started from a remote

location.

Both modules are available with or

without key start operation (please

specify ‘key’ or ‘NK’ on ordering).

FEATURES• Manual start or remote Start• Engine pre-heat• Engine monitoring and

protection features• Protected solid state (PSS)

outputs• Front panel mounting• Tamper proof engine hours

counter (702 only)• LED indicators

BENEFITS

• Hours counter providesaccurate information formonitoring maintenance andwarranty periods (702 only)

• Multiple engine parameters aremonitored simultaneously

OPERATION

MANUAL MODE• The module is started using the

on-board key/buttons• The user turns the key to the

position

• The engine pre-heat button is then

pressed for the required time

• The start button is then pressed tostart the engine

• To stop the engine the key needs

to be turned to the off position

 AUTOMATIC MODE

 Auto Start versions

• The key needs to be permanently

left in the posit ion

• The module is powered up by theremote start signal

• The pre-heat function isautomatically carried out and thenthe engine is started

• To stop the engine the remoteswitch is turned to the ‘off’position

OVERSPEED PROTECTION The engine over speed trip settingcan be calibrated at the rear of themodule for 50Hz or 60Hz nominaloperation (57Hz or 68Hz triprespectively).

ELECTRICAL SAFETY 

BS EN 60950Safety of Information Technology Equipment,including Electrical Business Equipment

ELECTRO MAGNETIC COMPATIBILITY 

BS EN 61000-6-2EMC Generic Immunity Standard for theIndustrial Environment

BS EN 61000-6-4EMC Generic Emission Standard for theIndustrial Environment

TEMPERATURE(OPERATING)

BS EN 60068 Test Ab to +70oC 60068-2-2 Hot Test Ab to -30oC 60068-2-1 Cold

 VIBRATION

BS EN 60068-2-6 Ten sweeps i n each of three major axes5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn

HUMIDITY 

BS 2011 part 2.1 60068-2-30 Test Cb Ob Cyclic93% RH @ 40oC for 48 hours

SHOCK 

BS EN 60068-2-27

 Three shocks in each of three major axes15gn in 11mS

IP RATING

BS EN 60529Degrees of protection provided by enclosures• IP65 NK version only• IP41 With Key version only

 Applies to Front of module when installed intothe control panel with the supplied sealinggasket.

DC SUPPLY 

8V to 35V continuous

CRANKING DROPOUTS

 Able to survive 0V for 50mS, providing supply

was at least 10V before dropout and supply

recovers to 5V. This is achieved without the

need for internal batteries.

 ALTERNATOR INPUTFREQUENCY 

50Hz – 60Hz at rated engine speed

(minimum:15V Overspeed: nominal

frequency +14% (+24% overshoot)

 ALTERNATOR INPUTRANGE

15V-305V AC RMS (+20%)

START OUTPUTSolid state 1.2A negative grounding terminal

RUN OUTPUT

Solid state 1.2A negative grounding terminal

PRE-HEATOUTPUT

Solid state 1.2A negative grounding terminal

DSE701 DIMENSIONS

72mm x 72mm x 38mm

2.8” x 2.8” x 1.5”

Excludes key switch

DSE701 PANEL CUT OUT

68mm x 68mm

2.7” x 2.7”

DSE702 DIMENSIONS

84mm x 72mm x 34.9mm

3.3” x 2.8” x 1.4”

Excludes key switch

DSE702 PANEL CUT OUT

80mm x 68mm

3.1” x 2.7”

DSE701 & DSE702 AUTO & MANUAL START CONTROL MODULES

DSE701 DSE702

Page 2: Dse 701 & Dse 702 Auto &Manual Start Control Modules

7/15/2019 Dse 701 & Dse 702 Auto &Manual Start Control Modules

http://slidepdf.com/reader/full/dse-701-dse-702-auto-manual-start-control-modules 2/2

®

RELATED MATERIALSTITLE PART NO’S

DSE701/702NK Installation Instructions 053-002DSE701/702K Installation Instructions 053-003DSE701/702 Manual Key Installation Instructions 053-016

DEEP SEA ELECTRONICS INC

3230 Williams Avenue

Rockford

IL 61101-2668 USA 

TELEPHONE

+1 (815) 316 8706

FACSIMILE

+1 (815) 316 8708

EMAIL

[email protected]

WEBSITE

www.deepseausa.com

DEEP SEA ELECTRONICS PLC

Highfield House

Hunmanby Industrial Estate

Hunmanby, North Yorkshire

 YO14 0PH England

TELEPHONE

+44 (0)1723 890099

FACSIMILE

+44 (0)1723 893303

EMAIL

[email protected]

WEBSITE

www.deepseaplc.com

Registered in England & Wales No.01319649 VAT No.316923457

DEEP SEA ELECTRONICS PLC maintains a policy of continuous development and reserves the right to

change the details shown on thisdata sheet withoutprior notice.The contents are intendedfor guidance only.

055-033/01/10 (3)

 This data sheet is printed on 9lives 55 Silk, which is produced with 55% recycled fibre

from both pre and post-consumer sources, together with 45% virgin ECF fibre.

FUSE

L1 N

GEN VOLTS

L1

L2

L3

N

   -     V     E

    +     V     E

     F     U     E     L

     C     R     A     N     K

     P     R     E   -     H     E     A     T

     C     H     R     G     A     L     T

     O     I     L     P     R     E     S     S     U     R     E

     C     O     O     L     A     N     T     T     E     M     P

     A     U     X     I     N     P     U     T     O     N

     M     A     N     U     A     L     S     T     A     R     T

     R     E     M     O     T     E     S     T     A     R     T

     O     N     A     U     T     O

     S     T     A     R     T

BATTERY 

CHARGE

 ALT

WL

2 AMP

FUSE

BATTERY CRANK 

SOLENOID

FUEL

SOLENOID

BATTERY NEGATIVE MUST BE GROUNDED

TERMINALS SUITABLE FOR 22-16 AWG (0.6mm - 1.3mm ) FIELD WIRING

TIGHTENING TORQUE = 0.8Nm (7lb-in)

* NOTE. ALL THE OUTPUTS ARE SOLID STATE AND ARE NEGATIVE SWITCHING

**NOTE FOR NK VERSION ONLY: THIS SWITCH MUST BE CAPABLE OF

SWITCHING THE TOTAL LOAD OPERATED BY RELAYS A,B AND C

**

FUSE

 A B C

MODULE 701 / 702

10 11

1 2 3 4 5 67 8 9

+

*

+

*

+

*

FROM

GENERATOR

DSE701 & DSE702