ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. © Ruskin December 2014 Spec ELF6375DXD-1214/Replaces ELF6375DXD-513 STANDARD CONSTRUCTION FRAME Box frame, 6" (152) deep, 6063T6 extruded aluminum with .081" (2.1) nominal wall thick- ness. Downspouts and caulking surface pro- vided. Universal Installation Frame: Same material and gages as above with flange. BLADES 6063T6 extruded aluminum .081" (2.1) nominal wall thickness. Drainable blades are positioned at 37 1 /2° angle. SCREEN 5 /8" x .040" (16 x 1) expanded, flattened alu- minum bird screen in removable frame. FINISH Mill. APPROXIMATE SHIPPING WEIGHT 14 lbs./ft. (68 kg/perm’) MINIMUM SIZE 12"w x 12"h (305 x 305). MAXIMUM SIZE Box Frame and Universal Installation Frame: 88”w x 120”h (2236 x 3048) factory assem- bly, unlimited width x 120”h (3048) field assembly. Unlimited height x 88”w (2236) in vertical configuration. INSTALLATION The ELF6375DXD must be installed per the appropriate Installation Detail. Reference the appropriate separate Installation Instruction Sheets. Consult Ruskin for additional information. Dimensions in inches, parenthesis ( ) indicate millimeters. FEATURES • Box Frame construction for use in cast-in- place concrete, grout filled CMU, Wood and steel installations. Approved for use in open structures with pro- visions to manage weather infiltration (wet rooms). Maximum windload ±148 PSF (7.08 kPa). 57% Free Area. • Published performance ratings based on testing in accordance with AMCA Publication 500-L. • Approved for use in closed structures with provisions to manage weather infiltration when combined with optional CD550 control damper. VARIATIONS • Universal Flange Frame construction when fasteners penetrating the wall are not utilized. Universal Flange Frame allows installation in walls up to 10” (254) and in any wall material. Also available for walls up to 15” (381) deep with UFF15 frame. • Optional finishes available at additional cost: prime coat, 50% PVDF (modified fluoropoly- mer), epoxy, Acrodize, 70% PVDF, clear and color anodize. (Some variations in anodize color consistency is possible.) Consult Ruskin for other special requirements. *Please provide Rough Opening Dimensions for A & B dimensions . Unless ordered as actu- al size, louvers will be provided smaller than the A & B dimensions provided. Universal Flange Frame louvers will be undersized 1 /2" (13) from the rough opening dimensions pro- vided. Louvers with the Box Frame will be undersized 1 /2" (13) from the rough opening dimensions provided. Louvers ordered as Actual Size will not be undersized. Order acknowledgements for actual size orders or orders with engineering drawings may show actual louver frame dimen- sions less sleeve thickness. SIZE TAG QTY. FRAME WALL DEPTH A*-WIDE B*-HIGH VARIATIONS PROJECT LOCATION ARCH./ENGR. CONTRACTOR REPRESENTATIVE DATE B ELF6375DXD meets the requirements for the following: Miami-Dade NOA Approval 12-0601.22 Florida Product Approved FL12226.2 AMCA 500-L Tested Please reference our website www.ruskin.com for up to date LEED® information. A B 6” (152) 3900 Dr. Greaves Rd. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955 ELF6375DXD DRAINABLE STATIONARY LOUVER MIAMI-DADE APPROVED MIAMI-DADE COUNTY, FLORIDA NOTICE OF ACCEPTANCE NUMBER: 12-0601.22 (Expires 7/9/16 ) Florida Product Approval #FL12226.2

ELF6375DXD DRAINABLE STATIONARY LOUVER - Sweets · Louvers shall be stationary type contained within a 6” (152) frame. Louver components (heads, jambs, sills, blades, and mullions)

Embed Size (px)

Citation preview

Page 1: ELF6375DXD DRAINABLE STATIONARY LOUVER - Sweets · Louvers shall be stationary type contained within a 6” (152) frame. Louver components (heads, jambs, sills, blades, and mullions)

ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. © Ruskin December 2014Spec ELF6375DXD-1214/Replaces ELF6375DXD-513

STANDARD CONSTRUCTIONFRAME

Box frame, 6" (152) deep, 6063T6 extrudedaluminum with .081" (2.1) nominal wall thick-ness. Downspouts and caulking surface pro-vided.Universal Installation Frame: Same materialand gages as above with flange.

BLADES6063T6 extruded aluminum .081" (2.1)nominal wall thickness. Drainable bladesare positioned at 371/2° angle.

SCREEN5/8" x .040" (16 x 1) expanded, flattened alu-minum bird screen in removable frame.

FINISHMill.

APPROXIMATE SHIPPING WEIGHT14 lbs./ft. (68 kg/perm’)

MINIMUM SIZE12"w x 12"h (305 x 305).

MAXIMUM SIZEBox Frame and Universal Installation Frame:88”w x 120”h (2236 x 3048) factory assem-bly, unlimited width x 120”h (3048) fieldassembly. Unlimited height x 88”w (2236) invertical configuration.

INSTALLATION The ELF6375DXD must be installed per theappropriate Installation Detail. Reference theappropriate separate Installation InstructionSheets.

Consult Ruskin for additional information.Dimensions in inches, parenthesis ( ) indicatemillimeters.

FEATURES• Box Frame construction for use in cast-in-

place concrete, grout filled CMU, Wood andsteel installations.

• Approved for use in open structures with pro-visions to manage weather infiltration (wetrooms).

• Maximum windload ±148 PSF (7.08 kPa).• 57% Free Area.• Published performance ratings based on

testing in accordance with AMCA Publication500-L.

• Approved for use in closed structures withprovisions to manage weather infiltrationwhen combined with optional CD550 controldamper.

VARIATIONS• Universal Flange Frame construction when

fasteners penetrating the wall are not utilized.• Universal Flange Frame allows installation in

walls up to 10” (254) and in any wall material.Also available for walls up to 15” (381) deepwith UFF15 frame.

• Optional finishes available at additional cost:prime coat, 50% PVDF (modified fluoropoly-mer), epoxy, Acrodize, 70% PVDF, clear andcolor anodize. (Some variations in anodizecolor consistency is possible.)

Consult Ruskin for other special requirements.*Please provide Rough Opening Dimensionsfor A & B dimensions. Unless ordered as actu-al size, louvers will be provided smaller thanthe A & B dimensions provided. UniversalFlange Frame louvers will be undersized 1/2"(13) from the rough opening dimensions pro-vided. Louvers with the Box Frame will beundersized 1/2" (13) from the rough openingdimensions provided.Louvers ordered as Actual Size will not beundersized. Order acknowledgements foractual size orders or orders with engineeringdrawings may show actual louver frame dimen-sions less sleeve thickness.

SIZETAG QTY. FRAME WALL

DEPTHA*-WIDE B*-HIGH

VARIATIONS

PROJECT LOCATIONARCH./ENGR. CONTRACTORREPRESENTATIVE DATE

B

ELF6375DXD meets the requirements forthe following:• Miami-Dade NOA Approval 12-0601.22• Florida Product Approved FL12226.2• AMCA 500-L Tested

Please reference our websitewww.ruskin.com for up to date

LEED® information.

A

B

6”(152)

3900 Dr. Greaves Rd. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955

ELF6375DXD DRAINABLE STATIONARY LOUVERMIAMI-DADE APPROVED

MIAMI-DADE COUNTY, FLORIDA NOTICE OF ACCEPTANCE NUMBER: 12-0601.22 (Expires 7/9/16 )Florida Product Approval #FL12226.2

Page 2: ELF6375DXD DRAINABLE STATIONARY LOUVER - Sweets · Louvers shall be stationary type contained within a 6” (152) frame. Louver components (heads, jambs, sills, blades, and mullions)

WATER PENETRATIONTest size 48" wide x 48" high (1219 x 1219)

Beginning point of water penetration at .01 oz./sq. ft. is 1023 fpm (312 m/min).

Oz. W

ater

/ft2

and

(oun

ces

wate

r/m2 )

of F

ree

Area

15 m

in. t

est p

erio

d

900(274)

1000(305)

1100(335)

1200(366)

1300(396)

1400(427)

0.3(3.23)

0.25(2.69)

0.2(2.15)

0.15(1.61)

0.1(1.08)

0.05(.54)

0

Free Area Velocity in feet (meters) per minuteStandard air .075 lb/ft3

PERFORMANCE DATA

Furnish and install louvers as hereinafter specified where shown onplans or as described in schedules. Drainable stationary louvermeeting the performance criteria established by the Florida BuildingCode and Miami-Dade County. Combination louvers shall be certi-fied to FBC standards TAS 201 (Large Missile Impact), TAS 202(Uniform Static Air Pressure) and TAS 203 (Cyclic Wind Loading).Louvers shall be manufactured in an 1SO 9001 certified factory.

Louvers shall be stationary type contained within a 6” (152) frame.Louver components (heads, jambs, sills, blades, and mullions) shallbe factory assembled by the louver manufacturer. Louver sizes toolarge for shipping shall be built up by the contractor from factoryassembled louver sections to provide overall sizes required.

Louvers shall be Ruskin Model ELF6375DXD construction as follows:MATERIALFrame: .081" (2.1) aluminum channel. Blades: .081" (2.1) nominal wall thickness.Extended .081" (2.1) wall thickness with upturned side panels to Screen: 5/8" mesh x .040" (16 x 1) expanded flattened aluminum

bird screen in removable frame. Drainable blades arepositioned at 371/2°.

Finish: Select finish specification from Ruskin/Valspar FinishesBrochure.

Published louver performance data bearing the AMCA CertifiedRatings Seal for Air Performance and Water Penetration must besubmitted for approval prior to fabrication and must demonstratepressure drop equal to or less than the Ruskin model specified.STRUCTURAL DESIGNIntegral structural supports shall be designed and furnished by thelouver manufacturer to carry a wind load of not less than ±148 psf(7.08 kPa).

SUGGESTED SPECIFICATION

Page 3: ELF6375DXD DRAINABLE STATIONARY LOUVER - Sweets · Louvers shall be stationary type contained within a 6” (152) frame. Louver components (heads, jambs, sills, blades, and mullions)

FREE AREA GUIDEFree Area Guide shows free area in ft2 and m2 for various sizes of ELF6375DXD.

Width – Inches and MetersHe

ight

– In

ches

and

Met

ers

0.310.030.580.050.860.081.140.111.410.131.690.161.970.182.240.212.520.232.800.263.080.293.350.313.630.343.910.36

0.490.050.930.091.380.131.820.172.260.212.700.253.150.293.590.334.030.374.470.424.920.465.360.505.800.546.250.58

0.670.061.280.121.890.182.500.233.110.293.720.354.330.404.940.465.550.526.160.576.760.637.370.687.980.748.590.80

0.860.081.630.152.400.223.180.303.950.374.720.445.500.516.270.587.050.667.820.738.590.809.370.87

10.140.94

10.921.01

1.040.101.980.182.920.273.870.364.800.455.750.536.690.627.630.718.570.809.510.88

10.450.97

11.401.06

12.341.15

13.281.23

1.220.112.320.223.430.324.540.425.640.526.740.637.860.738.960.83

10.060.93

11.171.04

12.271.14

13.381.24

14.481.35

15.591.45

1.410.132.680.253.960.375.240.496.520.617.790.729.080.84

10.350.96

11.621.08

12.901.20

14.181.32

15.451.44

16.731.00

18.011.67

1.590.153.030.284.470.425.920.557.350.688.790.82

10.240.95

11.671.08

13.121.22

14.561.35

16.001.49

17.4410.9118.881.75

20.321.89

1.770.163.370.314.980.466.590.618.180.769.790.91

11.401.06

13.001.21

14.601.36

16.201.51

17.811.66

19.411.80

21.021.95

22.622.10

1.960.183.730.355.500.517.280.689.040.84

10.811.00

12.591.17

14.351.33

16.131.50

17.901.66

19.671.83

21.441.99

23.212.16

24.982.32

2.140.204.080.386.020.567.970.749.890.92

11.831.10

13.781.28

15.711.46

17.651.64

19.591.82

21.532.00

23.472.18

25.412.36

27.352.54

2.320.224.420.416.530.618.640.80

10.731.00

12.831.19

14.951.39

17.041.58

19.141.78

21.241.97

23.352.17

25.452.37

27.552.56

29.652.76

2.510.234.770.447.050.669.330.87

11.581.08

13.861.29

16.141.50

18.401.71

20.671.92

22.942.13

25.212.34

27.482.55

29.752.76

32.022.98

2.690.255.130.487.570.70

10.010.93

12.441.16

14.881.38

17.331.61

19.751.84

22.192.06

24.632.29

27.072.52

29.512.74

31.942.97

34.383.19

2.880.275.480.518.090.75

10.700.99

13.291.24

15.891.48

18.511.72

21.101.96

23.712.20

26.312.44

28.912.69

31.522.93

34.123.17

36.733.41

3.060.285.820.548.600.80

11.371.06

14.131.31

16.901.57

19.681.83

22.442.09

25.212.34

27.982.60

30.742.86

33.513.11

36.283.37

39.053.63

3.250.306.180.579.120.85

12.061.12

14.981.39

17.921.67

20.871.94

23.792.21

26.732.48

29.672.76

32.603.03

35.543.30

38.483.58

41.413.85

3.430.326.520.619.630.89

12.741.18

15.821.47

18.921.76

22.042.05

25.122.33

28.222.62

31.322.91

34.423.20

37.523.49

40.623.77

43.724.06

3.610.346.870.64

10.150.94

13.421.25

16.671.55

19.941.85

23.232.16

26.482.46

29.752.76

33.013.07

36.283.37

39.553.68

42.823.98

46.094.28

120.3018

0.4624

0.6130

0.7636

0.9142

1.0748

1.2254

1.3760

1.5266

1.6872

1.8378

1.9884

2.1390

2.29

120.30

180.46

240.61

300.76

360.91

421.07

481.22

541.37

601.52

661.68

721.83

781.98

842.13

902.29

962.44

1022.59

1082.74

1142.90

1203.05

PERFORMANCE DATA

INTAKE MODE

1.00 (248).90 (224).80 (199).70 (174).60 (149).50 (124).40 (100)

.30 (75)

.20 (50)

.10 (25)

.09 (22)

.08 (20)

.07 (17)

.06 (15)

.05 (12)

.04 (10)

.03 (7)

.02 (5)

.01 (2)

1.00 (248).90 (224).80 (199).70 (174).60 (149).50 (124).40 (100)

.30 (75)

.20 (50)

.10 (25)

.09 (22)

.08 (20)

.07 (17)

.06 (15)

.05 (12)

.04 (10)

.03 (7)

.02 (5)

.01 (2)

100

(30)

200

(61)

300

(91)

400

(122)

500

(152)

600

(183)

700

(213)

800

(244)

900

(274)

1000

(30

5)

2000

(61

0)

3000

(91

4)

4000

(12

19)

5000

 (15

24)

6000

(18

29)

7000

(21

34)

8000

(24

38)

9000

(27

34)

10,00

0 (30

48)

Stat

ic P

ress

ure

Drop

in In

ches

w.g

. an

d (P

a)

PRESSURE DROPTest size 48" wide x 48" high (1219 x 1219)

Air Velocity in feet and (meters) per minute through Free Area(Data corrected to standard air density and AMCA figure tested to 5.5)

EXHAUST MODE

Ruskin Com pany certifies that theELF6375DXD louver shown herein islicensed to bear the AMCA Seal. The rat-ings shown are based on tests and proce-dures performed in accordance withAMCA Publication 511 and comply withthe requirements of the AMCA CertifiedRat ings Program. The AMCA Certi fiedRat ings Seal applies to air performanceratings and water penetration ratings only.

Ratings do not include theeffect of a bird screen.

Page 4: ELF6375DXD DRAINABLE STATIONARY LOUVER - Sweets · Louvers shall be stationary type contained within a 6” (152) frame. Louver components (heads, jambs, sills, blades, and mullions)

INSTALLATION DATA

STANDARD WOOD INSTALLATION

STANDARD CONCRETE INSTALLATION

STANDARD STEEL INSTALLATION

STANDARD UNIVERSAL SLEEVE INSTALLATION

Page 5: ELF6375DXD DRAINABLE STATIONARY LOUVER - Sweets · Louvers shall be stationary type contained within a 6” (152) frame. Louver components (heads, jambs, sills, blades, and mullions)

STANDARD CMU WALL INSTALLATION

FRAME CONSTRUCTION (CONTINUED)

FRAME CONSTRUCTION ELEVATION

GENERAL NOTES:1. Reference separate Installation Instruction sheets for installation

details. Each frame style has a distinct installation method thatmust be compiled with for Miami-Dade Approval. It is the responsi-bility of the installing contractor to properly install the louvers perthe appropriate detail.

2. On special orders, Ruskin may provide submittal and/or shopdrawings. Reference these drawings for additional installationinformation.

3. Continuous angles and fasteners supplied with UFF louvers areshipped loose.

4. Louvers may be provided with hidden vertical blade supports(HVBS) that increase overall installation depth by several inches.Consult Ruskin Louver Engineering for exact HVBS depth.

5. Louvers wider than the maximum single section width will beshipped in multiple sections and will require field assembly.

Maximum Width =Unlimited Maximum Width =

Unlimited

Max. Height120” (3048)

Max. Height120” (3048)

Visible Mullion2” (51) Visible Mullion

2” (51)

Max. Single SectionWidth 88” (2236)

Max. Single SectionWidth 88” (2236)

ShipLOUVERREF

SectionShip Section

VFF INSTALATION BOX FRAME INSTALATION

LOUVERREF

Page 6: ELF6375DXD DRAINABLE STATIONARY LOUVER - Sweets · Louvers shall be stationary type contained within a 6” (152) frame. Louver components (heads, jambs, sills, blades, and mullions)

3900 Dr. Greaves Rd.Kansas City, MO 64030(816) 761-7476FAX (816) 765-8955www.ruskin.com