28
Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart Sdn. Bhd. www.greens.com.my

Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Embed Size (px)

Citation preview

Page 1: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Experience in Closed Anaerobic Digesters Operation

for POME Biogas Harnessing Under CDM Project

By

Ir. RM Subbiah and Tuan Haji Alui Ahmad

Green & Smart Sdn. Bhd.www.greens.com.my

Page 2: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Anaerobic Technology (no air required for microbial survival)

Page 3: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Traditionally used A.D. types in

POME treatment• Deep open tanks• Deep lagoons

(Biogas released to atmosphere, GHG)

Page 4: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

OPEN TANKOPEN TANK

Page 5: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

GHG contribute to global warming

POME Biogas contains 45% to 80% methane, which has 21 times higher global warming potential than CO2

Page 6: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

New AD types used for

POME treatment based on

“Clean Development Mechanism” (CDM) principles

• Closed lagoon with covering• Closed tanks with stirring

(Biogas harnessed)

Page 7: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

CLOSED LAGOONCLOSED LAGOON

Page 8: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Completely Stirred Tank (CST)System

Stir the tank content by:

•Using biogas itself•Using stirrers•Using pumps

Page 9: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

POME – MAS TM

Palm Oil Mill Effluent – Mesophilic Anaerobic System

Temperature range 320C – 400C

Page 10: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

POME-MASTM System

Page 11: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

System used in 4 Palm Oil MillsTotal digesters : 12

Sizes:1700m3, 2200m3, 3600m3, 5800m3

Page 12: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart
Page 13: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

ResultsResults COD Reduction Efficiency COD Reduction Efficiency

All Digesters Design Mill 1 Mill 2

COD Inlet

(mg/L)55000

Range

42700 – 65940

Mean

55349

Range

26500 - 151700

Mean

54577

COD Outlet (mg/L)

5000

Range

2585 – 4537

Mean

3721

Range

2832 – 7690

Mean

4421COD

Reduction90% 93.22% 90.10%

Feed Quantity m3/day 120 288

Page 14: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Graph Showing Typical Results On Daily BasisGraph Showing Typical Results On Daily BasisFigure 1: 1700 m3 Anaerobic Digester Monitoring Results

Page 15: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Figure 2: 3600 m3 Anaerobic Digester Monitoring Results

Page 16: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Reactors are running sustainably for more than 12 months

Longest running > 24 months

Page 17: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Biogas production depends on• Effluent flow rate• Incoming COD value• Effluent temperature

Page 18: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Typical ValuesTypical Values

Mill production: 40T FFB/HrPOME: 24m3/Hr

Incoming COD total: 55,000 mg/lCOD reduction efficiency in the digester: 92%

Methane production: 425m3/hrBiogas at 60% CH4 content: 708m3/Hr

Theoretical power generation potential: 1274kW-1558kW

Page 19: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

COD reduction values measured in POME-MASTM

varies from 90% to 95%

Page 20: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

CH4 (Methane) values measured in POME-MASTM

varies from 60% to 75%

Page 21: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

BIOGAS PRODUCTION AT DIFFERENT COD REDUCTION EFFICIENCIES & DIFFERENT METHANE CONTENT

Mill capacity FFB m3/hr 40

Effluent Flow rate m3/hr 24

Inlet COD Mg/l 55 000

COD reduction efficiency see table

Assumption : Running on full load on above capacity1 kg COD reduction gives 0.35m3 Methane

Biogas Production at different methane

concentration

Biogas Production at different COD reduction % (m3/hr)

75% 80% 85% 90% 95%

At 55 % 630 672 714 756 798

At 60 % 578 616 655 693 732

At 65 % 533 569 604 640 675At 70 % 495 528 561 594 627

Page 22: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

ESTIMATED ELECTRICITY PRODUCTION

Electricity Production

COD reduction efficiency 75% 80% 85% 90% 95%

Biogas Production at 60% methane concentration 578 616 655 693 732

Potential electrical power at 2kW* hr/m3 of biogas

(kWh)1156 1232 1310 1386 1464

* Can vary from 1.8kW to 2.3kW per m3 of biogas based on generator efficiency

Page 23: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Efficiency Difference - Commercial Value

Every 5% difference in gas production means extra 500,000 kWh/year

@ RM 0.30/kWh = RM 150,000For 21 years SREP feed in tariff difference in

revenue = RM 3.15million

Page 24: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Flare

CDM compliant GREEN-FLARETM

Exhaust temperature set 6100C maintained at 610 + 30C

Gas retention time about 0.86 seconds

Page 25: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart
Page 26: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart
Page 27: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Conclusion

• POME-MASTM system gives high COD reduction efficiency > 90%• Takes shock loads

• CH4 contents 60% to 75% in Biogas

• Runs in sustainable manner either on continuous or batch feed mode • GREEN-FLARETM (CDM compliant closed flare)

maintains same set exhaust temperature for different gas flows

Page 28: Experience in Closed Anaerobic Digesters Operation for POME Biogas Harnessing Under CDM Project By Ir. RM Subbiah and Tuan Haji Alui Ahmad Green & Smart

Thank You

Presenter:Ir. RM.Subbiah (012-2181903)

Green & Smart Sdn. Bhd.www.greens.com.my