9
Page 1 of 9 Item Body Capacity Separation between supports Radius upper supports , mm Flexural Fixtures 3 Points PFb-3P-150/2.5 Aluminum 2.5 kN 4-150 mm 1 support of 1 - 1.5 - 2 - 3.2 ó 5 mm de radius to chooser * PFb-3P-300/10 Steel 10 kN 4-190 mm PFb-3P-420/10 Steel 10 kN 4-420 mm PFb-4P/2.5 Aluminum 2.5 kN 4-150 mm PFb-4P/10 Steel 10 kN 4-150 mm PFb-4P-300/10 Steel 10 kN 4-300 mm Flexure Bending Fixtures PFb 3 & 4 Points - 2,5 kN y 10 kN (low capacity) 2,5 kN Aluminum 10 kN Steel Flexural Fixtures 4 Points The 3 Point Bending Test Devices are supplied including 1 set of 3 supports of the chosen radius (see specifications below) The 4 Point Bending Test Devices are supplied including 1 set of 4 supports of the chosen radius (see specifications below) Radius lower supports, mm Combinations 2 radiuss p/support (R1,5 y R2,5 mm), (R2 y r3 mm) (R3,2 y R5 mm)** * The upper supports have individual radios ** The lower supports have 2 radius, are reversible with different radius of support on each side The sample to be tested is placed on the supports of the lower area of the bending test device and then the 3 or 4 point flexural strength test is carried out. - RTemperature range -70ºC to 180ºC PFb-FU 2-3 PFb-FOR2 PFb-AR1.5-R2.5 -AR2-R3 -AR,.3-R5 -R4-R5 Suitable for accurate bending tests of small samples 10 kN 4-290 mm PFb-3P-150/10 Steel TECHLAB SYSTEMS, S.L. Head Office: Txatxamendi 10, Pol. 110 – 20100 Lezo – SPAIN US Office: 1549 Ardmore Ave. –Itasca, Illinois 60143 USA www.metrotec.es

Flexure Bending Fixtures PFb 4 P - 2,5 kN y 10 kN (low ... · ó 5 mm de radius to chooser * PFb-3P-300/10 Steel 10 kN 4-190 mm PFb-3P-420/10 Steel 10 kN 4-420 mm PFb-4P/2.5 Aluminum

Embed Size (px)

Citation preview

Page 1 of 9

Item Body Capacity Separation between supports

Radius uppersupports , mm

Flexural Fixtures 3 Points

PFb-3P-150/2.5 Aluminum 2.5 kN 4-150 mm

1 support of 1 - 1.5 - 2 - 3.2

ó 5 mm de radius to chooser *

PFb-3P-300/10 Steel 10 kN 4-190 mm

PFb-3P-420/10 Steel 10 kN 4-420 mm PFb-4P/2.5 Aluminum 2.5 kN 4-150 mm PFb-4P/10 Steel 10 kN 4-150 mm PFb-4P-300/10 Steel 10 kN 4-300 mm

Flexure Bending Fixtures PFb 3 & 4 Points - 2,5 kN y 10 kN (low capacity)

2,5 kN Aluminum 10 kN Steel

Flexural Fixtures 4 Points

The 3 Point Bending Test Devices are supplied including 1 set of 3 supports of the chosen radius (see specifications below) The 4 Point Bending Test Devices are supplied including 1 set of 4 supports of the chosen radius (see specifications below)

Radius lowersupports, mm

Combinations 2 radiuss p/support (R1,5 y R2,5 mm), (R2 y r3 mm)(R3,2 y R5 mm)**

* The upper supports have individual radios

** The lower supports have 2 radius, are reversible with different radius of support on each side

The sample to be tested is placed on the supports of the lower area of the bending test device and then the 3 or 4 point flexural strength test is carried out.

- RTemperature range -70ºC to 180ºC

PFb-FU 2-3

PFb-FOR2

PFb-AR1.5-R2.5 -AR2-R3 -AR,.3-R5 -R4-R5

Suitable for accurate bending tests of small samples

10 kN 4-290 mm

PFb-3P-150/10 Steel

TECHLAB SYSTEMS, S.L.Head Office: Txatxamendi 10, Pol. 110 – 20100 Lezo – SPAIN

US Office: 1549 Ardmore Ave. –Itasca, Illinois 60143 USA www.metrotec.es

Elements: Item. Length Scope of supply

PFb/B200 200mm 1

PFb/B300 300mm 1

PFb/430 430mm 1

Item.

Lower bar support for:

Upper bar supportfor :

Radios, mmAlcance suministro

PFb/AR…

Combinations Radius (AR - R): 1.5 y 2.5, 2.0 y 3.0 2.0 y 5.0 3.2 y 5.0 4.0 y 5.0

1 Par

PFb/CR….

0.5 1 2 3.2 5 10

1 Par

PFb/AX 1.5-2.5, 2.0-3.0 2.0-5.0 3.2-5.0 4.0-5.0

1 Par

PFb/CX 4 Point Flexural Fixtures

Only 1 Radius (AR): 0.5 1 2 3.2 5 10

1 Par

PFb/CWX Articulated Rollers Only upper anvil for

the 3 Points Flexure Fixtures

1.0 1.5 2.0 3.2 5.0

1 Par

PFb/CN Smooth support for glass testing

For Rollers of Ø 1- 3.2mm 1 Par

PFb/CWM Flat moveable for glas 1 Par

PFb/CWN Plain bearing with rocker shaft and stop support 3

mm high 1 Par

Page 2 of 9

Lower support:

3 point device

4 point device

4 Point Flexural Fixtures

Only 1 Radius (FOR):

Suitable for: 3 Points Flexural Fixtures 4 Points Flexural Fixtures

Flexure Bending Fixtures PFb 3 & 4 Points - 2,5 kN y 10 kN (low capacity)

TECHLAB SYSTEMS, S.L.Head Office: Txatxamendi 10, Pol. 110 – 20100 Lezo – SPAIN

US Office: 1549 Ardmore Ave. –Itasca, Illinois 60143 USA www.metrotec.es

3 point device

4 point device

Suitable for: 3 Points Flexural Fixtures 4 Points Flexural Fixtures

Additional anvil for the 3 Points Flexure

Fixtures

Combinations Radius(AR):

Combinations Radius (AR - R):

Rollers for PFb/X:

Yunques superiores Item Radios, mm Alcance del suministro

PFb/OR..

Un solo Radio (FR):

1.0 1.5 2.0 3.2 5.0

1 Pieza

PFb/oX2 For rollers of Ø 1- 3.2mm 1 Pieza

PFb/oX8 For rollers of Ø 4- 12.7mm 1 Pieza

PFb/oWXAxis with

interchangeable roller balance

For rollers of: 1,2,3,4,5,6, 6.35, 8, 10, 12, 12.7 mm Ø

1 Pieza

Item Description Scope of supply:

PFb/D…-3P

1 additional set of 3 rollers withX= 1,2,3,4,5,6, 6.35, 8, 10, 12, 12.7 mm Ø 3 Rollers

PFb/D…-4P

1 additional set of 4 rollers withX= 1,2,3,4,5,6, 6.35, 8, 10, 12, 12.7 mm Ø

4 Rollers

Page 3 of 9

Only upper anvil for the 3 Points Flexure

Fixtures

Only upper anvil for the 3 Points Flexure

Fixtures with interchangeable rollers

Only upper anvil for the 3 Points Flexure

Fixtures with interchangeable rollers

Flexure Bending Fixtures PFb 3 & 4 Points - 2,5 kN y 10 kN (low capacity)

TECHLAB SYSTEMS, S.L.Head Office: Txatxamendi 10, Pol. 110 – 20100 Lezo – SPAIN

US Office: 1549 Ardmore Ave. –Itasca, Illinois 60143 USA www.metrotec.es

PFb/CWXD5Flexure Fixture wit interchangeable rollersand aticulated bearings.

Includes 1 set of rollers the standard supply

Here with rollers of 5mm

Accessories for PFb-XW:

Item Body Capacity Separa.supports Roller diameters, mm

Flexural Fixture3 Points

PFb/XW Aluminum 2.5 kN 4-150 mm

1, 2, 3, 4, 5, 6, 6.35, 8, 10, 12, 12.7

PFb/XW-St Steel 10 kN 4-150 mm PFb/XW-300-St Steel 10 kN 4-300 mm PFb/XW-4P Aluminum 2.5 kN 4-150 mm PFb/XW-4P-St Steel 10 kN 4-150 mm PFb/XW-300-4P-St Steel 10 kN 4-300 mm

Item. Lower bar support for:

Upper bar support for :

Supply

PFb-CWXFor:3 Point Bending Device or3 Point Bending Device

4 Point Flexure FixtureFor the rollers with 1,2,3,4,5,6, 6.35, 8, 10, 12, 12.7 mm Ø

1 Par

Page 4 of 9

Radius, mm

PFb/FWX

PFb/CWX

TECHLAB SYSTEMS, S.L.Head Office: Txatxamendi 10, Pol. 110 – 20100 Lezo – SPAIN

US Office: 1549 Ardmore Ave. –Itasca, Illinois 60143 USA www.metrotec.es

Flexural Fixture4 Points

Flexure Bending Fixtures PFb 3 & 4 Points - 2,5 kN y 10 kN (low capacity)

PFb/AX-F5x150

Wide support rollers, to test

samples easy to bend

PFb/AX

Interchangeable rollers, to test

samples 2 sizes prisms

PFb/CWR1Z -S3

Smooth supports, for small distances,

with rolling

PFb/CWR1Z-H80-S3

Smooth support for small distances with rollingHere it is possible the installation of a small displacement transducer inductive, in the area underneath rocker

PFb/CWXD4-GAf159

Devices with interchangeable rollers.

For example for testing of Flex 4 points

on test pieces of glass-ceramic

PFb/DF-AL (Aluminio)PFb/DF-ST (Acero)

1 EXTRA - Bending beam including 2xPFb/AR Convert an existing 3-point bending device to a 4-point bending device.

Available in aluminium or steel

PFb-DF-ALPFb-DF-ST

Page 5 of 9 TECHLAB SYSTEMS, S.L.

Head Office: Txatxamendi 10, Pol. 110 – 20100 Lezo – SPAIN US Office: 1549 Ardmore Ave. –Itasca, Illinois 60143 USA

www.metrotec.es

Flexure Bending Fixtures PFb 3 & 4 Points - 2,5 kN y 10 kN (low capacity)

Soluciones especiales a medida

PFb/4P-CWL-D5

Device Fexion to 4 points with rocker wheels and swivel(needle bearings)

PFb/4P-CWXDx180

Page 6 of 9

Flexure Bending Fixtures PFb 3 & 4 Points - 2,5 kN y 10 kN (low capacity)

TECHLAB SYSTEMS, S.L.Head Office: Txatxamendi 10, Pol. 110 – 20100 Lezo – SPAIN

US Office: 1549 Ardmore Ave. –Itasca, Illinois 60143 USA www.metrotec.es

PFb

PFb/B300--4P-CWR5x170

PFb/4P-CWXD8-iTH1-AfDP10s iTH1

Camera adaptor thermal tests at

different temperatures, with

inductive sensor

Page 7 of 9

Flexure Bending Fixtures PFb 3 & 4 Points - 2,5 kN y 10 kN (low capacity)

TECHLAB SYSTEMS, S.L.Head Office: Txatxamendi 10, Pol. 110 – 20100 Lezo – SPAIN

US Office: 1549 Ardmore Ave. –Itasca, Illinois 60143 USA www.metrotec.es

PFb

PFb/4P-CWXD15x180

PFb/CWXD4 iTH1 Support piece for installing an internal extensometer 8mm

Page 8 of 9

Flexure Bending Fixtures PFb 3 & 4 Points - 2,5 kN y 10 kN (low capacity)

TECHLAB SYSTEMS, S.L.Head Office: Txatxamendi 10, Pol. 110 – 20100 Lezo – SPAIN

US Office: 1549 Ardmore Ave. –Itasca, Illinois 60143 USA www.metrotec.es

PFb

PFb/CWXD4-iTH2 Part support for balancing, to adapt an external extensometer

PFb/CR01 Small Radio Supports 0.1mm

Page 9 of 9

Code 2848Adapter (with balancing) for the placement of LVDT to Flexure Bending Test Device according to ISO 178 standards...

Flexure Bending Fixtures PFb 3 & 4 Points - 2,5 kN y 10 kN (low capacity)

TECHLAB SYSTEMS, S.L.Head Office: Txatxamendi 10, Pol. 110 – 20100 Lezo – SPAIN

US Office: 1549 Ardmore Ave. –Itasca, Illinois 60143 USA www.metrotec.es