Folio™ Wall Hung Desk Frame
Non-Seismic Applications*
If you have a problem, question, or request, callyour local dealer, or Steelcase Line 1 at888.STEELCASE (888.783.3522)for immediate action by people who want to help you.
(Outside the U.S.A., Canada, Mexico, Puerto Rico,and the U.S. Virgin Islands, call: 1.616.247.2500)Or visit our website: www.steelcase.com© 2016 Steelcase Inc.Grand Rapids, MI 49501 U.S.A.
Printed in U.S.A.
®
Page 1 of 425324601 Rev B
CLAMP
WOOD BLOCK
3/8" SPADE BIT
MASKING TAPE(Used to help preventany possible chipping
while drilling)
WARNINGCRUSH HAZARD! FAILURE TO PROPERLY SECURE CABINET COULDRESULT IN PERSONAL INJURY
Read the entire assembly direction before beginning installation.
Building construction varies greatly. The Building’s Engineer of Record is responsiblefor the design of building walls which the cabinets are attached to and must verifythe adequacy of the mounting hardware,even if provided by Steelcase.
The building owner or designated agentis responsible for verifying that the installation is in compliance with all localcodes and regulations.
5/32" HEX DRIVE BIT
* The building’s Engineer of Record must be consulted to determine if there are any seismic requirements.
Page 2 of 425324601 Rev B
VERIFY WALL CONSTRUCTION
MINIMUM REQUIRED WALL CONSTRUCTIONS:
CAUTION! Adequate wall construction is requiredto support the weight of loaded cabinets.
Drywall with Metal Studs
- Must be at least 25 ga. (0.018” min. thk.) 33 ksi steel studs 1.5” x 3.5” - Studs on maximum 24” centers - Must be at least 5/8” thick Type X gypsum drywall (per ASTMC36, ASTMC1396, and CAN/CSA-A82.27M) - 16 ga (0.063") metal banding, 6” wide min., at centerline 32" and 14-1/4” from floor
Drywall with Wood Studs
- Stud grade SPF, DF-L or Hem-Fir 1.5" x 3.5" - Studs on maximum 24" centers - Must be at least 5/8" thick Type X gypsum drywall (per ASTMC36, ASTMC1396, and CAN/CSA-A82.27M) - Wood blocking, 6" wide min., at centerline 32" and 14-1/4” from floor
WARNING
SIDE VIEWFRONT VIEW
32"
= (6) FACTORY INSTALLED SCREWS= (2) SCREWS INSTALLED THROUGH CLEAT & INTO BLOCKING= (2) SCREWS INSTALLED THROUGH CABINET BACK, CLEAT & INTO BLOCKING = (1) SCREW INSTALLED THROUGH CABINET BACK, SPACER BOARD & INTO WALL STUD
FLOOR
1
234
3
2
1
BLOCKING
WALL STUD
CRUSH HAZARD. Failure to properly secure cabinet could result in personal injury. Read entire Assembly Direction for your product mounting configuration. Verify all walls meet minimum required construction guidelines before beginning installation. Install ALL fasteners required. Obtain assembly directions from a Steelcase dealer or call 1-888-783-3522.
Note: The above wall construction assumes a nominal36” AFF counter height. Banding locations should beadjusted accordingly for alternate counter heights.
34”
36”
29”
Counter HeightAFF
Upper bandCenterline
Lower bandCenterline
30”
32”
25”
12-1/4”
14-1/4”
7-1/4”
4
1 LOWERBAND
14-1/4”
Installing a Desk Between Two Cabinetsonto Drywall
1. Pull drawer(s) forward from the base cabinet(s) (1a). Removedrawer(s) completely by one of the methods shown below (1b).Push slide rails back into base cabinet(s).TIP: Mark all drawers so they can be easily re-installed in theiroriginal positions.
2. Place desk frame between the base cabinets or tall storageand secure to wall using #14-14 x 3” sheet metal screws.
1a
OROR
1b
2
DRAWER
SLIDE
ROLLER ON CASE
ROLLER ON DRAWER
Page 3 of 425324601 Rev B
Page 4 of 425324601 Rev B
3. Use existing clearance holes in desk frame sides fordrilling location. Drill two (2) holes through side of deskframe assembly and into base cabinet or tall storage.
NOTE: Use masking tape to prevent any possible chippingwhile drilling and backup with clamped wood block.
4. Secure desk frame assembly to base cabinet or tallstorage using two (2) 1-1/2" connector bolts. Repeat steps3 and 4 for other end of desk frame assembly.
5 If desk frame is 60", 66" or 72" wide, install reinforcementchannel underneath worksurface toward the front.Secure using eight (8) 1/2" wood screws.
6. Re-install drawers into the base cabinets.
4
4x
3
FOR 60", 66" & 72" WIDTHS ONLY
1/2" WOODSCREW
REINFORCEMENTCHANNEL
WORKSURFACE
1-1/2" CONNECTORBOLT
WOOD BLOCK
Clamp a wood block onother side of panel toprevent excessiveblowout.Use a sharp 3/8" drill bitto drill holes through.
5
MASKING TAPE