PiPe | Fittings | ValVes | sheet | Rod | tanks | Flexible tubing | instaduct | FRP gRating | scRubbeR Packing | instRumentation | FlowmeteRs | PumPs
PLASTICS FOR TODAY’S INDUSTRIES
FRP - Fiber Reinforced Plastic & Grating
FABCO FRP MOLDED GRATING Fabco offers a full range of Fiberglass Molded Grating Panels for most any application- With a grate thickness range of 1”, 1 ½” and 2” and mesh sizes of 1” x 4”, 1 ½” x 1 ½” or 2” x 2” we have the ability to supply you with panels that meet your projects loading demand � We have a full complement of resin selections available that can be offered with grit top or a plain non-skid surface� Panel sizes are varied and range from 4’ x 12’ 4’ x 8’ and 3’ x 10’�
FABCO FRP PULTRUDED GRATINGOur Pultruded FRP Grating Product range offered in either poly or vinyl ester flame retardant resins� It is available with Individual bearing bars in various sizes of “I” or “T” shapes or Heavy Duty solid bars up to 2 ½”. This provides Fabco the ability to supply a pultruded grating profile to handle a range of applications from light foot traffic walkways to heavy vehicle traffic in any corrosion environment�
FABCOGRATE FRP GRATING & FABCORAIL FRP SAFETY RAILING
FABCO PHENOLIC GRATING Phenolic grating is a dramatic innovation for markets where fire safety is a major concern; it offers superior resistance to flame and high temperature with low emissions of smoke and toxic fumes. The nonflammable nature of phenolics enable phenolic grating to withstand higher temperatures than polyester or vinyl ester for extended periods of time without major structural damage�
FABCORAIL FRP SAFETY RAILING Our Safety Railing is fabricated from structural FRP components manufactured by the pultrusion process� Fabco Plastics stocks a wide variety of Safety Railing which can ship from stock for easy on-site assembly� Our standard handrail is a 2-rail system manufactured in a “Safety Yellow” color.
10
FRP - FIBER REINFORCED PLASTIC & GRATING
285www.fabcoplastics.com
PiPe | Fittings | ValVes | sheet | Rod | tanks | Flexible tubing | instaduct | FRP gRating | scRubbeR Packing | instRumentation | FlowmeteRs | PumPs
CF: CHEMICAL PROOF (standard colour is dark gray) is a vinyl ester system specifically engineered to provide premium service in highly corrosive environments. It utilizes an advanced resin system which delivers outstanding resistance to a wide range of harsh corrosive environments ranging from acidic to caustic, plus a high degree of solvent resistance. It has a Class I flame spread rating of 25 or less according to the ASTM E-84 Tunnel Test Method.CR+: CHEMICAL PROOF PLUS (standard colour is black). This is our only EF.R.P™ Grating to offer a flame spread rating of 10 or less on ASTM E-84 Tunnel Test. It has excellent acid and caustic resistance.IF: INDUSTRIAL GRADE (standard colour is light gray). This is a premium corrosion resistant isophthalic resin system selected for outstanding acid resistance. It has moderate resistance to caustic and solvent environments. It has a Class I ASTM E-84 Tunnel Test flame spread rating of 25 or less. It is more economical than types CF and CR+.FF: FOOD GRADE (standard colour is safety yellow). Agriculture Canada approved (all ingredients have been USDA approved) to meet corrosive conditions commonly found in meat production, food processing, bottling and brewing applications. Made with isophthalic polyester. Flame spread rating is 30 or less.AF: ARCHITECTURAL GRADE FIRE RETARDANT (standard colour is light gray). This is a resin system designed for mildly corrosive environments. Best suited to replace metal gratings that require maintenance to maintain an aesthetically pleasing appearance. It has a Class 1, ASTM E-84 Tunnel Test flame spread rating of 25 or less for indoor use. It is more economical than type IF.AN: ARCHITECTURAL GRADE (standard colour is green). Similar resin system as type AF but is not fire retardant or flame spread rated. More economical than AF.
RESIN CODE DESCRIPTION
BASE RESIN
CORROSION RESISTANCE
FLAME SPREAD RATING COLOR
CF CHEMICAL PROOF FIRE RETARDANT VINYL ESTER EXCELLENT CLASS 1: 25 OR LESS DARK GRAY or ORANGE
CR+ CHEMICAL PROOF FIRE RETARDANT PLUS VINYL ESTER EXCELLENT CLASS 1: 10 OR LESS BLACK
IF INDUSTRIAL GRADE FIRE RETARDANT ISOPHTHALIC VERY GOOD CLASS 1: 25 OR LESS GREEN or GRAY
FF FOOD GRADE FIRE RETARDANT ISOPHTHALIC VERY GOOD CLASS 2: 30 OR LESS LIGHT GRAY
AF ARCHITECTURAL GRADE ORTHOPHTHALIC GOOD CLASS 1: 25 OR LESS GREEN
AN ARCHITECTURAL GRADE NON-FIRE RETARDANT ORTHOPHTHALIC GOOD NOT RATED YELLOW or GREEN
Note : All grating types available with or without grit top for slip resistance.
Fabcograte FRP GratingFeatures:• Will not rust. • Corrosion
resistant. • Non-sparking. • Fire retardant. • Non-conductive.
• Maintenance free. • Molded-in color. • Light weight. • Easy to install. • Impact resistant. • Quality
appearance.
Rectangular Mesh Panel• 1” HIGH • Bar Spacing: 1” X 4” • 1” Weight: 2.50 lb/ft. sq. • Tolerances: ±1/16” • Economical • Original pattern • 69% open area • Widely used for light traffic and shorter spans
Square Mesh Panel• Three Heights 1”, 1.5” and 2”• 1.5“ Weight: 3.75 lb/ft. sq. • 1“ Weight: 2.5 lb/ft. sq. • Tolerances: ±1/16” • Bar Spacing: 1.5” X 1.5” • Most popular pattern • 70% open area • Load bearing bars in both directions • Easy to fabricate • Can be used without continuous side
support • Labour savings • High material utilization, low waste • Uniform appearance
THICKNESSBAR SPACING
(IN)PANEL SIZE
(FT)WT
(LBS)
1" 1.5 x 1.5 4 X 12 120
1" 1.5 x 1.5 4 X 10 100
1" 1.5 x 1.5 4 X 8 80
1" 1.5 x 1.5 3 X 12 90
1" 1.5 x 1.5 3 X 10 75
1" 1.5 x 1.5 5 X 10 125
1.5" 1.5 x 1.5 4 X 12 180
1.5" 1.5 x 1.5 4 X 10 150
1.5" 1.5 x 1.5 4 X 8 120
1.5" 1.5 x 1.5 3 X 12 135
1.5" 1.5 x 1.5 3 X 10 113
1.5" 1.5 x 1.5 5 X 10 187
1" 1 x 4 3 X 10 75
1" 1 x 4 44" X 8 75
1" 1 x 4 4 X 8 80
1" 1 x 4 4 X 12 120
2" 2 x 2 4 X 12 192
FRP Grating
10
FRP
- FIB
ER R
EINF
ORCE
D PL
ASTI
C &
GRAT
ING
www.fabcoplastics.com286
Grating Selection Process1. Select the proper bar spacing and height to meet your load requirements.2. Select the proper resin to meet your environmental requirements.3. Select the proper panel size to meet your requirement.4. Determine if you want grit top or plain top.
Deflection to Span Ratios • For a resilient, non-fatiguing, comfortable feel use the STANDARD deflection to span ratio of 1:120. • For an elevated installation, where a solid feeling is desired, use a deflection to span ratio of 1:180 (NBC-85).
A deflection to span ratio greater than 1:100 (1%) is not recommended. Do not exceed .5” (13mm).
Load Deflection Tables
Panel Installation • Panels are designed to be supported on all sides. • Use end clips if panel ends cannot be supported. • Use hold down clips to prevent panel drift.
Panel Selection • Determine the type of loading: concentrated or uniform. • Estimate the load and determine the span. • Decide what maximum deflection is appropriate: solid, standard or 1%. • Enter the appropriate 1” (25mm) table. If the deflection is less than the maximum selected, choose the 1”
thickness. It is more economical than 1.5” thick panels. • If the deflection or span is too great for 1” thick panels, select 1.5” thick FRP Grating and design your support
system for the appropriate span. • Select the resin system.
CONCENTRATED LOAD: FULL PANEL2” HEIGHT, 2” X 2” MESHSPAN LOAD (POUNDS) MAXIMUM LOADS
(IN) 100 250 500 750 1000 1500 2000 SOLID2 STD3
1% DEF4
18 .004 .012 .025 .037 .049 .074 .098 2040 3063 367224 .007 .018 .036 .054 .072 .107 .143 1860 2793 3352361 .015 .037 .073 .110 .146 .219 .293 1290 1938 2326481 .030 .074 .149 .223 .298 .447 858 1286 1554
1-1/2” HEIGHT, 1-1/2” X 1-1/2” MESH18 .007 .016 .032 .048 .064 .096 .128 1560 2340 280824 .012 .029 .058 .086 .115 .173 .230 1156 1733 2080361 .026 .064 .128 .192 .255 .383 738 1108 1330481 .055 .138 .276 .414 463 693 832601 .083 .208 .417 386 579 695
1” HEIGHT, 1-1/2” X 1-1/2” MESH18 .014 .034 .068 .102 .136 .203 .271 738 1105 132524 .026 .066 .132 .198 .265 .397 503 755 906361 .068 .171 .342 276 414 497481 .141 .353 181 272 326
1” HEIGHT, 1” X 4” MESH18 .011 .028 .056 .084 .113 .169 .225 887 1330 159624 .025 .061 .123 .184 .245 .368 .491 543 813 976361 .059 .147 .294 .441 321 482 578441 .120 .300 213 320 384481 .131 .327 196 294 353
UNIFORM LOAD: FULL PANEL2” HEIGHT, 2” X 2” MESHSPAN LOAD (LB/FT2) MAXIMUM LOADS
(IN) 40 65 75 100 150 200 250 SOLID2 STD3
1% DEF4
12 .00 .00 .00 .00 .00 .00 .00 4867 5800 580018 .003 .004 .005 .007 .010 .014 .017 1439 2158 259024 .009 .014 .016 .022 .033 .044 .055 607 910 1092361 .044 .072 .083 .111 .167 .222 .278 180 269 323481 .141 .228 .264 .351 76 111 133601 .343 32 46 55
1-1/2” HEIGHT, 1-1/2” X 1-1/2” MESH12 .002 .003 .004 .005 .008 .010 .013 2664 5918 710218 .005 .008 .010 .013 .019 .025 .032 787 2358 283024 .016 .026 .030 .040 .060 .080 .101 331 745 894361 .081 .132 .153 .204 .305 .407 98 145 174481 .258 .419 .484 41 60 72
1” HEIGHT, 1-1/2” X 1-1/2” MESH12 .003 .006 .008 .010 .016 .021 .026 633 950 114018 .021 .035 .040 .053 .080 .107 .133 187 281 33724 .067 .110 .126 .169 .253 .337 .422 78 118 142361 .342 23 35 42
1” HEIGHT, 1” X 4” MESH12 .002 .004 .005 .006 .009 .012 .014 1158 1737 208418 .010 .016 .018 .024 .036 .048 .060 416 625 75024 .022 .036 .042 .056 .084 .112 .140 238 356 427361 .110 .180 .207 .276 .414 72 108 130441 .31 34 50 60481 .339 31 46 55
Notes:• 1 - Clear Span is 2” less than width of grating• 2 - Solid Deflection to Span ratio is 1:180
• 3 - Standard Deflection to Span ratio is 1:120• 4 - 1% Deflection to Span ratio is 1:100
FRP Grating
10
FRP - FIBER REINFORCED PLASTIC & GRATING
287www.fabcoplastics.com
FRP Grating AccessoriesGrating Accessories
Fiberglass Covered GratingAll Fiberglass Grating is available with an integral cover plate to prevent fumes in the work area or where high stiffness over drainage trenches is required.
Fiberglass Floor PlateAvailable to cover all panel sizes. Easy to clean both top and bottom sides. Can be used as a splash guard. Available in thickness from 1/16” (1.5mm) to 1” (25mm). Grit top surface is standard for floor plate applications.
Fiberglass Stair TreadsFiberglass stair treads come complete with contrasting colored antislip nosing. Available in standard lengths of 24”, 30”, 36”, or 42”. Available in widths of 9”, 10 1/2”, or 12”.
Fiberglass Concrete Curb AnglePultruded fiberglass Curb Angle provides a strong, firm base for bearing bars. Standard Curb Angle is produced using a gray, fire retardant vinyl ester resin system and is available in three sizes.
Fiberglass Elevated Floor SystemsFixed and adjustable Fiberglass Columns are available to provide elevated dry floor. Strongwell’s pultruded fiberglass Curb Angle provides a strong, firm base for bearing bars. Standard Curb Angle is produced using a gray, fire retardant vinyl ester resin system and is available in three sizes. Floors can be designed to support up to 2,000 pounds per square foot.
Grating ClipsPrevent panel drift - bold, nut and washer included. Use 2 or 3 for each side of each full size panel; 4 for each Stair Thread. 18-8 stainless steel. The following Types are available:
Type M ClipsRestrains movement in all directions. Can use self-drilling screws when attaching to metal supports.
Type G-G ClipsInstall from top of grating. No hole to drill. Galvanized available.
Type J ClipsFor moderate loads.
Type CFor joining two unsupported ends.
10
FRP
- FIB
ER R
EINF
ORCE
D PL
ASTI
C &
GRAT
ING
www.fabcoplastics.com288
Pultruded Fiberglass Grating
How to Specify DURADEK®Fiberglass grating shall be DURADEK® Series (I-6500 1") (I-6500 1-½") (T-5800 2") as manufactured by Strongwell. Grating shall be pultruded and assembled in the U.S.A. Resin shall be fire retardant (polyester) (vinyl ester) meeting the requirements of a Class 1 rating of 25 or less per ASTM E-84 and the self-extinguishing requirements of ASTM D-635. Color shall be (light gray) (yellow). Resin shall be UV inhibited and the composite shall include a veil on all exposed surfaces. Panels shall be assembled into the sizes ordered using a 3-piece pultruded cross-rod system.The cross-rods shall consist of a center core wedge and two spacer bars that are notched at each bearing bar so that each bearing bar is both mechanically locked and chemically bonded to the web of each bearing bar. The spacer bars shall be continually bonded to the center core wedge. The cross-
SHAPES, SIZES AND AVAILABILITYSERIES BEARING BAR
THICKNESSNO. BARS PER
FT. WIDTHBEARING BAR
CENTEROPEN SPACE
OPEN AREA
APPROX. WEIGHT PER FT2
CROSS-SECTIONAL AREA
(PER FT. OF WIDTH)
MOMENT OF INERTIA
(PER FT. OF WIDTH)
SECTION MODULUS(PER FT. OF WIDTH)
I-6500 1.0" 7 1.71" 1.11" 65% 2.2 lb 2.190 in2 0.288 in4 0.575 in3
I-6500 1.5" 7 1.71" 1.11" 65% 2.7 lb 2.752 in2 0.814 in4 1.088 in3
T-5800 2.0" 5 2.40" 1.40" 58% 2.6 lb 2.711 in2 1.396 in4 top: 1.588 in3
bottom: 1.247 in3
DURADEK®
How to Order When ordering DURADEK®, ensure the bearing bars for installation will be oriented in the correct direction for the application. Bearing bars shall traverse from support to support. Cross-rods are not intended to be applied in the span direction. The adjacent drawing will help specify the width and length of panels.NOTE: Width is the measurement from end to end of the cross-rods. Length is always the bearing bar length.Panel Sizes Are Specified: Width x LengthNOTE: DURAGRID®, Strongwell's line of custom pultruded grating, is available with a wide array of options, including: colors, resin systems, panel sizes, cross rod spacings and more.
Nosings for Stair Treads and LandingsDURAGRID® pultruded stair treads and landings are produced by attaching a 2" deep nosing to the leading edge. This gives added strength and rigidity to the area that takes the most impact and abuse. In addition, the nosing provides more surface area for skid resistance, wear and better visibility. Light gray stair treads with yellow nosing are available at additional cost.
TREAD WIDTH & COLORSTAIR TREAD
SERIES
MAXIMUM SPAN FOR300 LBS. AT MIDSPAN
1/8” OR LESS DEFLECTION
1/4” OR LESS DEFLECTION
11" Light Gray or Yellow I-6000 1” 29” 37”11" Light Gray or Yellow I-6000 1-1/2” 40” 52”12" Light Gray or Yellow T-5000 2” 47” 59”
rods shall be spaced a maximum of 8" in the panel. The top of the panels shall be covered with a bonded epoxy medium grit anti-skid surface.NOTE: If special options are required that are not stated in the above specification, fill in your special requirement in the appropriate section.
10
FRP - FIBER REINFORCED PLASTIC & GRATING
289www.fabcoplastics.com
Pultruded Fiberglass GratingDURADEK® Accessories
USING THE LOAD/DEFLECTION TABLESSeries DesignationThe series designation indicates the bar size and shape and the percent of open area.For example: T-5800 2" means 2" T-bar spaced to give a 58% open area.
Load Table DataDeflection values are based upon minimum apparent modulus (E) per span. Maximum Recommended Load data was calculated by the Strongwell Test Lab. See FGMC/ANSI Grating Manual for additional information regarding apparent modulus deflection.
STATISTICAL REPORTING METHODSMinimum ValueA value that is a specified distance from the average. The most common specified distance is three standard deviations.
Characteristic ValueAs defined by ASTM D7290, a value that is normally between two and three standard deviations from the average.
Average ValueThe sum of a list of values divided by the number of values in the list, without consideration for standard deviations.
Typical ValueNo definition. Not recommended for use by Professional Engineers. Can be any value the manufacturer chooses.
NOTE: Strongwell recommends the use of minimum or characteristic values for design calculations
10
FRP
- FIB
ER R
EINF
ORCE
D PL
ASTI
C &
GRAT
ING
www.fabcoplastics.com290
Pultruded Fiberglass GratingFiberglass Grating & Stair Treads
10
FRP - FIBER REINFORCED PLASTIC & GRATING
291www.fabcoplastics.com
Pultruded Fiberglass Grating
10
FRP
- FIB
ER R
EINF
ORCE
D PL
ASTI
C &
GRAT
ING
www.fabcoplastics.com292
Pultruded Fiberglass Grating
SPAN (IN)
STYLE LOAD IN LB / SQUARE FOOT (PSF) MAXIMUM RECOMM-
ENDED LOAD (PSF)
DEFLE-CTION
E X 106
PSISERIES DEPTH 50 100 150 200 250 300 400 500 750 1000 2000 3000 4000 5000 6000
12I-6500 1" <0.01 <0.01 <0.01 <0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.04 0.06 0.08 0.1 9123 0.19 3.78I-6500 1-½" <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 0.01 0.01 0.02 0.02 0.03 0.04 0.04 15439 0.11 3.79T-5800 2" <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 0.01 0.01 0.02 0.02 0.03 9444 0.04 3.8
18I-6500 1" 0.01 0.01 0.01 0.02 0.02 0.03 0.04 0.05 0.07 0.1 0.19 0.29 0.38 0.48 4346 0.41 4.15I-6500 1-½" <0.01 <0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.07 0.1 0.14 0.17 0.21 6862 0.24 4.05T-5800 2" <0.01 <0.01 <0.01 <0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.04 0.06 0.08 0.1 0.12 6280 0.13 3.91
24I-6500 1" 0.01 0.03 0.04 0.06 0.07 0.09 0.11 0.14 0.21 0.28 0.57 2544 0.72 4.41I-6500 1-½" 0.01 0.01 0.02 0.02 0.03 0.03 0.04 0.05 0.08 0.1 0.21 0.31 0.42 0.52 0.63 3860 0.4 4.24T-5800 2" <0.01 0.01 0.01 0.01 0.02 0.02 0.03 0.03 0.05 0.06 0.13 0.19 0.26 4722 0.3 4.01
30I-6500 1" 0.03 0.07 0.1 0.13 0.17 0.2 0.26 0.33 0.49 0.66 1628 1.07 4.63I-6500 1-½" 0.01 0.03 0.04 0.05 0.06 0.07 0.1 0.12 0.18 0.25 0.49 2433 0.6 4.4T-5800 2" 0.01 0.02 0.02 0.03 0.04 0.05 0.06 0.08 0.12 0.15 0.31 3022 0.46 4.1
36I-6500 1" 0.07 0.13 0.2 0.26 0.33 0.39 0.52 0.66 1130 1.48 4.83I-6500 1-½" 0.03 0.03 0.05 0.08 0.1 0.12 0.15 0.2 0.25 0.37 0.5 1663 0.83 4.5T-5800 2" 0.02 0.02 0.03 0.05 0.06 0.08 0.09 0.12 0.16 0.23 0.31 2099 0.66 4.18
42I-6500 1" 0.12 0.24 0.36 0.48 0.6 827 1.99 4.88I-6500 1-½" 0.05 0.09 0.14 0.18 0.23 0.27 0.36 0.45 0.68 1194 1.08 4.59T-5800 2" 0.03 0.06 0.09 0.11 0.14 0.17 0.23 0.29 0.43 1542 0.88 4.25
48I-6500 1" 0.2 0.4 0.6 630 2.53 4.98I-6500 1-½" 0.08 0.15 0.23 0.3 0.38 0.46 0.61 892 1.35 4.66T-5800 2" 0.05 0.1 0.14 0.19 0.24 0.29 0.38 1181 1.12 4.34
54I-6500 1" 0.32 0.64 496 3.18 5I-6500 1-½" 0.12 0.24 0.36 0.48 0.6 681 1.64 4.71T-5800 2" 0.08 0.15 0.23 0.3 0.38 933 1.4 4.41
60I-6500 1-½" 0.18 0.36 0.55 533 1.94 4.74T-5800 2" 0.11 0.23 0.34 0.45 756 1.7 4.47
66I-6500 1-½" 0.27 0.53 425 2.26 4.76T-5800 2" 0.16 0.33 0.49 624 2.04 4.52
72 T-5800 2" 0.23 0.46 524 2.39 4.58
Note:
10
FRP - FIBER REINFORCED PLASTIC & GRATING
293www.fabcoplastics.com
Pultruded Fiberglass Grating
SPAN (IN)
STYLE LOAD IN LB / FOOT OF WIDTH (PSF) MAXIMUM RECOMM-
ENDED LOAD (PSF)
DEFLE-CTION
E X 106
PSISERIES DEPTH 50 100 150 200 250 300 400 500 750 1000 2000 3000 4000 5000 6000
12I-6500 1" <0.01 <0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.03 0.03 0.07 0.10 0.13 0.17 4561 0.15 3.78I-6500 1-½" <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 0.01 0.01 0.01 0.01 0.02 0.04 0.05 0.06 0.07 7719 0.09 3.79T-5800 2" <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 0.01 0.01 0.01 0.02 0.03 4722 0.03 3.8
18I-6500 1" 0.01 0.01 0.02 0.02 0.03 0.03 0.04 0.05 0.08 0.10 0.20 0.31 0.41 0.51 3259 0.33 4.15I-6500 1-½" <0.01 <0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.03 0.04 0.07 0.11 0.15 0.18 0.22 5146 0.19 4.05T-5800 2" <0.01 <0.01 <0.01 <0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.05 0.07 0.09 4722 0.11 3.91
24I-6500 1" 0.01 0.02 0.03 0.05 0.06 0.07 0.09 0.11 0.17 0.23 0.45 0.68 2544 0.58 4.41I-6500 1-½" 0.01 0.01 0.01 0.02 0.02 0.03 0.03 0.04 0.06 0.08 0.17 0.25 0.33 0.42 0.50 3860 0.32 4.24T-5800 2" <0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.03 0.04 0.05 0.10 0.15 0.21 4722 0.24 4.01
30I-6500 1" 0.02 0.04 0.06 0.08 0.11 0.13 0.17 0.21 0.32 0.42 2035 0.86 4.63I-6500 1-½" 0.01 0.02 0.02 0.03 0.04 0.05 0.06 0.08 0.12 0.16 0.31 0.47 0.63 3041 0.48 4.4T-5800 2" 0.01 0.01 0.02 0.02 0.03 0.03 0.04 0.05 0.07 0.10 0.20 0.30 3778 0.37 4.1
36I-6500 1" 0.04 0.07 0.11 0.14 0.18 0.21 0.28 0.35 0.52 1696 1.19 4.83I-6500 1-½" 0.01 0.03 0.04 0.05 0.07 0.08 0.11 0.13 0.20 0.27 0.53 2495 0.66 4.5T-5800 2" 0.01 0.02 0.03 0.03 0.04 0.05 0.07 0.08 0.13 0.17 0.33 3148 0.52 4.18
42I-6500 1" 0.06 0.11 0.17 0.22 0.28 0.33 0.44 0.55 1447 1.59 4.88I-6500 1-½" 0.02 0.04 0.06 0.08 0.10 0.12 0.17 0.21 0.31 0.41 2088 0.86 4.59T-5800 2" 0.01 0.03 0.04 0.05 0.07 0.08 0.10 0.13 0.20 0.26 2698 0.7 4.25
48I-6500 1" 0.08 0.16 0.24 0.32 0.40 0.48 0.64 1260 2.02 4.98I-6500 1-½" 0.03 0.06 0.09 0.12 0.15 0.18 0.24 0.30 0.46 0.61 1784 1.08 4.66T-5800 2" 0.02 0.04 0.06 0.08 0.10 0.11 0.15 0.19 0.29 0.38 2361 0.9 4.34
54I-6500 1" 0.11 0.23 0.34 0.46 0.57 0.68 1117 2.55 5I-6500 1-½" 0.04 0.09 0.13 0.17 0.21 0.26 0.34 0.43 0.64 1533 1.31 4.71T-5800 2" 0.03 0.05 0.08 0.11 0.13 0.16 0.21 0.27 0.40 2099 1.12 4.41
60I-6500 1-½" 0.06 0.12 0.18 0.23 0.30 0.35 0.47 0.58 1333 1.56 4.74T-5800 2" 0.04 0.07 0.11 0.14 0.18 0.22 0.29 0.36 1889 1.36 4.47
66I-6500 1-½" 0.08 0.16 0.23 0.31 0.39 0.46 0.62 1170 1.81 4.76T-5800 2" 0.05 0.10 0.14 0.19 0.24 0.29 0.38 1717 1.63 4.52
72 T-5800 2" 0.06 0.12 0.18 0.24 0.30 0.37 1574 1.92 4.58
Note:
10
FRP
- FIB
ER R
EINF
ORCE
D PL
ASTI
C &
GRAT
ING
www.fabcoplastics.com294
Pultruded Fiberglass GratingDURAGRID® I-Bar Pultruded Grating
10
FRP - FIBER REINFORCED PLASTIC & GRATING
295www.fabcoplastics.com
Pultruded Fiberglass GratingDURAGRID® T-Bar Pultruded Grating
10
FRP
- FIB
ER R
EINF
ORCE
D PL
ASTI
C &
GRAT
ING
www.fabcoplastics.com296
Pultruded Fiberglass Grating &Pultruded Fiberglass GratingDURAGRID® HD Pultruded Grating
10
FRP - FIBER REINFORCED PLASTIC & GRATING
297www.fabcoplastics.com
Pultruded Fiberglass Grating &
DuratreadTM Fiberglass Stair Tread Covers
Fiberglass Stair Tread CoversDURAGRID® R-Bar Pultruded Grating