    Process Sweet, Sour and BTEX Gas

    Emit No Odor, Smoke nor Visible Flame

    Perform at 99.99% Combustion Efficiency

    Reduce Overall Project Cost

    QTI Incinerators:

    Questor Waste Gas Incinerators

    Questor Incinerators burn waste gases the most effectively of all combustion products.

    Extensive independent testing has proven that exhaust gases from Questor Incineratorsare combusted at 99.99% efficiency and contain no particulate matter, poly-nucleararomatic hydrocarbons (PAHs), or unburned hydrocarbons. There is no visible flame,

    .

    Over 100% excess air is mixed naturally with waste gases in a proprietary burnerassembly to achieve a 1350 C internal combustion temperature and a 1150 C stackexit temperature. Questors unique, high velocity exhaust vortex and high stack exittemperature create the most effective plume dispersion available.

    Questor Incinerators save our clients money through reduced fuel gas consumption,lower operating costs, less maintenance and smaller lease sizes.

    odor or smoke

    o o

    Exhaust gases

    No visible flameNo visible smoke

    No odor

    Air inGas In

    Questor Incinerators Reduce Overall Project Cost

    Questor Incinerators require less fuel gas to operate effectively on low heatcontent gases such as sour gas, acid gas, tail gas and dehydrator gas.

    Questor Incinerators reduce operating expenses because they operateunmanned, require little maintenance and are reliable. A vapor recoveryunit is not required to capture tank vapors. No external power is required.

    Reduce your site space. Flash arrest units and lallow close proximity to other equipment. No guy wires or

    open flame allow closer equipment spacing. Small sites mean lower pipingcosts.

    One stack efficiently combusts both high & low pressure waste gas streams.

    ow operating temperatureat ground level

    Proven Questor Technology

    Questor Incinerators have been independently and extensively tested in a variety of applications by clients includingExxon/Mobil, Shell, TransCanada Pipelines, Vacquero, and Dominion Exploration.

    Low Radiant Heat Allows Operation in

    Permafrost & High Hazard Environments

  • 8/3/2019 GeneralBrochureSept2004V1

    2/2

    Reduced Lease Size (75% H S)2

    Well Test (Portable Rentals)

    Amine Unit (Acid Gas / Tail Gas)

    Pipeline Blow Down

    Separator / Treater Gas& Tank Vapor Recovery

    Dehydrator Vapors (BTEX)& Stabilizer Gases

    Processes Both High & Low PressureWaste Gas Streams in One Unit

    Coal Bed Methane Testing

    Land Fill Waste Gas

    Pipeline within City of Calgary3 MM scf/d Well Test Trailer Unit

    Dehydrator Vapors (BTEX) & Stabilizer Gases

    Separator / Treater Gas & Tank Vapor Recovery

    Acid Gas / Tail Gas

    QTI Model

    Q 50Q 100Q 250Q 500Q 1000

    Q 3000Q 5000

    IncineratorFlow Rate

    10 - 5020 - 10050 - 250

    100 - 500100 - 1000

    300 - 3000500 - 5000

    (mscf/day)

    Questor Incinerator Applications