Imaging of Ocular Blood FlowGh.Naderian , MD

Page 2: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

The eye has two separate

and distinct circulatory

systems , the retinal and the

uveal.

Page 3: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

The retinal vascular

system nourishes the inner

retina.

Page 4: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

The uveal system supplies

the choroid , ciliary body and

iris.

Page 5: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

Color Doppler imaging:Color Doppler imaging (CDI) is an

ultrasound technique combining B-

Scan gray scale imaging and blood

velocity measurements

Page 6: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

CDI can be used to calculate peak

systolic velocities (PSVs) and end-

diastolic velocities (EDVs) in the

retrobulbar vessels , including the

OA,CRA and nasal and temporal

PCAs.

Page 7: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory
Page 8: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory
Page 9: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

Canon laser Blood Flowmeter

The canon laser blood flowmeter

(CLBF) is a recently developed

device used to simultaneously

quantify the velocity of blood within

large retinal vessels and their

diameter.

Page 10: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory
Page 11: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

Use of CLBF is limited by its

calculated flow assumptions ,

cataract , vitreous opacties ,

small pupills and eye movement.

Page 12: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

Heidelberg Laser Doppler Flowmetry

The confocal scanning laser doppler

flowmeter , also known as the

Heidelberg retina fowmeler (HRF) ,

combines a laser doppler flowmeter

with a confocal scanning laser

tomograph.

Page 13: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory
Page 14: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory
Page 15: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

Scanning Laser Ophthalmoscope Angiography

FA and ICG angiography

performed with a scanning lascr

opthalmoseope (SLO) can be

used to quantitate blood flow.

Page 16: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory
Page 17: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

In SLO angiography fluorescein dye

may be used to evaluale the retinal

vasculature to yield homodynamic

measurements such as arteriovenous

passage (AVP) and meam dye velocity

(MDV)

Page 18: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory
Page 19: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory
Page 20: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory
Page 21: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

Pulsatile Ocular Blood Flow Measurement

Pulsatile ocular blood flow

(POBF) devices consist of a

modifed Pneumotonometer

interfaced with a microcomputer

that records the ocular pulse.

Page 22: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

POFB monitors the rhytmic

change in intraocular

pressure (IOP) during the

cardiac cycle,which fluctuates

up to 2mm Hg in sinusoidal

fashion

Page 23: Gh.Naderian, MD. The eye has two separate and distinct circulatory systems, the retinal and the uveal. The eye has two separate and distinct circulatory

Clinical Applications1) Glaucomatous optic

Neuropathy

2) Diabetic Retinopathy

3) Age-related Macular

degeneration