4
ADVANCED COMMUNICATIONS SOLUTION DSE WebNet ® DSEWebNet® provides a web-based control and monitoring solution for DSE control modules all over the globe. DSEWebNet® supports single or multi-set systems via a range of devices, which support a suitable internet browser. This includes Laptop / PC, Smart Phone or Tablet devices. On-screen information presents real-time generator and system information in an easy to use format with a flexible means of data transmission through Ethernet or GSM 3G via the DSEWebNet ® Gateway device. Location information can be provided by an external GPS antenna connected to the DSEWebNet ® Gateway device. KEY BENEFITS Reduced site visits and maintenance costs Fuel management Fault analysis Asset tracking Automatic system alerts Maximises system up-time ® www.deepseaplc.com SUPPORTS COMMUNICATIONS THROUGH MULTIPLE PLATFORMS *Google Chrome or Internet Explorer 9 recommended for optimisation *

GPS antenna connected to the DSE WebNetdavidsonsalesshop.com/catalog/files/Products/Deep Sea...DSE Gateway DSE890 Installation Instructions DSE Gateway DSE890 Hardware Manual DSE Webnet

  • Upload
    others

  • View
    36

  • Download
    0

Embed Size (px)

Citation preview

  • ADVANCED COMMUNICATIONSSOLUTION

    DSEWebNet®

    DSEWebNet® provides a web-based control and monitoring solution for DSE control modules all over the globe.DSEWebNet® supports single or multi-setsystems via a range of devices, which support a suitable internet browser. This includesLaptop / PC, Smart Phone or Tablet devices.

    On-screen information presents real-timegenerator and system information in an easy touse format with a flexible means of datatransmission through Ethernet or GSM 3G viathe DSEWebNet® Gateway device. Locationinformation can be provided by an externalGPS antenna connected to the DSEWebNet®

    Gateway device.

    KEY BENEFITS– Reduced site visits

    and maintenance costs – Fuel management– Fault analysis– Asset tracking– Automatic system alerts– Maximises system up-time

    ®

    www.deepseaplc.com

    SUPPORTS COMMUNICATIONSTHROUGH MULTIPLE PLATFORMS

    *Google Chrome or Internet Explorer 9 recommended for optimisation

    *

  • DSEWebNet®

    DSEWebNet® IS THE IDEAL SOLUTION FOR EFFICIENTGENSET MAINTENANCE, FLEET MANAGEMENT,ASSET TRACKING, REMOTE/PERIODIC GENSETTESTING, FUEL MANAGEMENT, FAULT ANALYSIS &MUCH MORE. The DSEWebNet® system offers features such as mapping with staticlocations, real time instrumentation and control, event log tables andautomatic system alerts which are sent to multiple DSEWebNet® users viaemail and SMS.

    Comprehensive on-screen information is presented in clear, graphical andnumerical formats which is easy to navigate and operate.

    DSEWebNet® can be utilised to maximise system up-time by offering themost effective remote management tool.

    The DSEWebNet® Gateway device provides the user with full instant accessto the DSEWebNet® system. A single Gateway device can be connected toa maximum of twenty supported DSE controllers. This creates a vast andextensively featured remote control and site monitoring solution.

    An unlimited number of DSEWebNet® users can access a single Gatewaydevice. Additionally a single user can access an infinite number of Gatewaydevices. To gain access to either the Gateway Device or the DSEWebNet®,secure login information is required. This low cost solution makes thesystem a secure and effective remote monitoring and control solution formultiple users and sites.

    DSEWebNet®

    Smart Phone DevicesTablet Devices

    DSEWebNet® GatewayDSEWebNet® Gateway

    DSE Module

    DSE Module DSE Module DSE Module

    DSEWebNet® GatewayDSEWebNet® Gateway

    Laptop / PC

  • MANY OTHER SCREENS AREAVAILABLE SHOWING ACOMPREHENSIVE LIST OF ENGINE,GENERATOR, MAINS AND SYSTEMINFORMATION.

    DSEWebNet® IS DESIGNED TO WORK IN CONJUNCTION WITH THEDSEWebNet® Gateway DEVICE ANDIS AVAILABLE TO USE AFTERGATEWAY INSTALLATION.

    1 2

    3 4

    5 6

    Screen examples show the following information:

    1. Global mapping shows multiplesite locations

    2. Aerial view of a single site locationwith multiple generators

    3. Multiple or single site generatorevent recording & monitoring

    4. Engine monitoring5. Generator & mains monitoring6. DSE controller input & output state

    diagnostics

  • 055-117/02/12 (1) US

    DEEP SEA ELECTRONICS PLC UKHighfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PHTELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303EMAIL [email protected] WEBSITE www.deepseaplc.com

    DEEP SEA ELECTRONICS INC USA3230 Williams Avenue, Rockford, IL 61101-2668 USATELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708EMAIL [email protected] WEBSITE www.deepseausa.com

    Registered in England & Wales No.01319649VAT No.316923457

    Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to changethe details shown on this data sheet without prior notice. The contents are intended for guidance only.

    SPECIFICATION

    DC SUPPLYCONTINUOUS VOLTAGE RATING8 V to 35 V continuous

    CRANKING DROPOUTSAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropoutand supply recovers to 5 V. This is achievedwithout the need for internal batteries

    MAXIMUM OPERATING CURRENTGSM 700 mA at 12 V, 450 mA at 24 VGSM & GPS 700 mA at 12 V, 450 mA at 24 VEthernet 200 mA at 12 V, 110 mA at 24 VEthernet & GPS 700 mA at 12 V, 450 mA at 24 V

    MAXIMUM STANDBY CURRENTGSM 270 mA at 12 V, 150 mA at 24 VGSM & GPS 270 mA at 12 V, 150 mA at 24 VEthernet 150 mA at 12 V, 90 mA at 24 VEthernet & GPS 270 mA at 12 V, 150 mA at 24 V

    COMMUNICATIONSUSB (Single DSE Controller)RS232 (Single DSE Controller)RS485 (Multiple DSE Controllers)Ethernet (Multiple DSE Controllers)

    DIMENSIONS85mm x 149mm x 51mm

    ENVIRONMENTAL TESTING STANDARDS

    ELECTRO-MAGNETIC COMPATIBILITYBS EN 61000-6-2EMC Generic Immunity Standard for the Industrial EnvironmentBS EN 61000-6-4EMC Generic Emission Standard for the Industrial Environment

    ELECTRICAL SAFETYBS EN 60950Safety of Information Technology Equipment, including Electrical Business Equipment

    TEMPERATUREBS EN 60068-2-1Ab/Ae Cold Test -30 oCBS EN 60068-2-2Bb/Be Dry Heat +70 oC

    VIBRATIONBS EN 60068-2-6Ten sweeps in each of three major axes5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn

    HUMIDITYBS EN 60068-2-30Db Damp Heat Cyclic 20/55 oC@ 95% RH 48 HoursBS EN 60068-2-78Cab Damp Heat Static 40 oC@ 93% RH 48 Hours

    SHOCKBS EN 60068-2-27Three shocks in each of three major axes15 gn in 11 mS

    www.deepseaplc.com

    COMMUNICATIONSINTERFACE

    DSEWebNet® Gateway

    The DSEWebNet Gateway is used in conjunction withsupported DSE controllers to provide monitoring andcommunications data via the DSEWebNet® advancedcommunications system.

    The DSEWebNet Gateway communicates to theconnected DSE controller(s), monitoring theinstrumentation and operating state. When this datachanges, the new data is logged in the internal memory.At regular intervals the logged data is transmitted to theDSE host server.

    The DSE host server is then integrated into theDSEWebNet® which can be accessed via an internetconnected device and web browser to allow remotemonitoring and control of multiple DSE controllersaround the globe. GSM, GPS and GSM/GPS antenna’sare available as accessories.

    DSE890DSEWebNet®Gateway - 3G (GSM)/Ethernet

    The Gateway connects to the DSE data server byintegral Ethernet connection or GPRS (DSM or 3Gmobile internet) and includes GPS (satellite location)functionality. This is most suited to remote and/or mobilelocations.

    DSE891DSEWebNet®Gateway - Ethernet Only

    The Gateway connects to the DSE data server by anintegral Ethernet connection only. This is most suited forfixed installations where an ADSL / DSL cablebroadband service is available (external broadbandmodem required, not supplied by DSE).

    TITLEDSEGateway DSE890 Installation InstructionsDSEGateway DSE890 Hardware ManualDSEWebnet Software Manual

    PART NO’S053-140057-165057-168

    PARTGSM AntennaGPS AntennaGSM/GPS Antenna

    PART NO’S020-141020-130020-150

    RELATED MATERIALS

    ACCESSORIES

    COMPATIBLE DSE CONTROLLERS INCLUDE:

    DSE4410DSE6010DSE6110DSE7110

    DSE7210DSE7310DSE7410DSE8610

    DSE4420DSE6020DSE6120DSE7120

    DSE7220DSE7320DSE7420

    AUTO START MODULES AUTO MAINS FAILURE MODULES

    The DSEWebNet Gateway will soon be compatible with the DSE45xx, DSE87xx & DSE88xx range ofGenset Controllers.