32
HC BARCOL-AIR COMPANY PROFILE

HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

  • Upload
    others

  • View
    14

  • Download
    0

Embed Size (px)

Citation preview

Page 1: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC BARCOL-AIR COMPANY PROFILE

Page 2: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

2

Preface

It was 1934 when the agreement was signed between Barber-Colman USA and “Industrieele & Handels Mij” Amsterdam. Now, 2013 and 79 years later, we still develop, design, produce, market and sell air distribution products that provide an optimum in comfort and which uses a minimum in energy.

The world has changed since then. Luckily people do realize that our environment is important and that, if we want our children to have a happy and healthy life, we have to take care of our planet. With our latest product developments like the Induction-VAV terminals and our range of Chilled Beam products we have pleasure infor-ming your that we contribute to this. With these products and the knowledge of our controls division the highest LEED and BREEAM standards can be achieved.

Together with the other HC Groep companies we provide complete HVAC solutions and our clients like our ‘Single Source, Single Responsibility’ approach. The unity in our group is demonstrated by the new company logos which we recently introduced.

This brochure will give you a brief overview about HC Barcol-Air, the company and its products. If you need more information we ask you to consult our website (www.hcgroep.com), contact one of our partners in your country or feel free to contact us directly.

Lars WiersmaExport Manager

Page 3: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

3

Table of contents

Subject Page

Preface 2

Company introduction 4

Company vision 5

Introduction HC Groep 6

Single Source - Single Responsibility 7

Organisation 8

Climate laboratory & Product development 9

Acoustic reverberation room 11

Product overview 12 - 22

Combined expertise VAV and Controls 23

Induction VAV, the optimum indoor climate and energy efficient system 24

Induction VAV References 25

Export reference projects (other) 26 - 28

Distributors / partners 29 - 31

HC Barcol-Air continuously aspires to further optimise the construction and the quality of all products. HC Barcol-Air preserve themselves the right to carry out modifications in product specifications without notice or obligation. S.E. & O.

© Copyright Barcol-Air B.V. 2013

Nothing from this publication may be multiplied and/or made public by means of printing, photocopy, microfilm or in whatever manner, without preceding written authorisation of HC Barcol-Air.

Page 4: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

4

Company introduction

Mission statement

HC Barcol-Air is specialised in designing, developing and realising a perfect thermal in-door climate. All in compliance with the demands of the client, consultant and architect. For small and large projects, in standard and specific circumstances, from single products to complete installations, including design and climate laboratory test according to ISO standards.

The goal of HC Barcol-Air is to create an indoor climate which offers optimum comfort levels with a minimum of energy use.

Facts and figures

• Turnover HC Groep > 50 million euro and almost 200 employees

• 2 products groups: Air distribution & Controls > 70 employees

• > 70 years experience in indoor climate / thermal comfort

• Combined knowledge of Air distribution & Controls

• Added value by technical expertise• R&D departments, 6 engineers with

100 years combined experience• Full scale climate room > 250 tests• “Specials” > 2.500 special developed

products• > 200 large BMS projects• > 10.000 Air Distribution projects• Projects in > 50 countries with 35

distributors

ProductionDe Wilp

AssemblyPurmerend and Enkhuizen

HC Groep HC Barcol-Air OfficeHC RT OfficePurmerend

HC GroepHead Office HC GroepWaalwijk

Page 5: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

5

Company vision

Introduction

The main goal of HC Barcol-Air is designing and developing products and systems to create and control the environment in commercial buil-dings, using a minimum energy and providing optimal comfort.

HC Barcol-Air is a domestic market leader with good international presence. A trendsetter through technical expertise and a wide range of excellent products.

The name HC Barcol-Air must be synonym for thermal comfort and quality.

One Source, One Responsibility

The “One Source, One Responsibility” concept combines a substantial product and system portfolio, know-how, service and experience to one efficient centre of excellence. All compo-nents are designed to form complete integrated systems, which guarantee perfect operating and performing HVAC installations.

Specialist in air distribution products

HC Barcol-Air is manufacturer and supplier of a complete range of high quality Barber Colman air distribution products and systems. These can be supplied with a short delivery time mainly from stock. Together with a range of standard products HC Barcol-Air has all facili-ties (R&D department & climate laboratory) to develop, test and manufacture specific products and systems and to provide a total and best comfort solution.

Extensive know-how and cooperation with other company product groups (controls, chilled ceiling and service) results in the best possible solution for every HVAC application, with project specific designs if needed. HC Barcol-Air likes to implicate all its know-how and experience in the early stage of the project, to be able to act as partner in designing the best possible installation. Clients, consultants and contractors can count on the technical support of our sales engineers, supported by our R&D team and climate laboratory facilities.

History

The origin dates back to 1933, when Barber Colman started to develop Air Distribution products and controls.

Timeline:

1900 BARBER-COLMAN Company (USA)

1932 Start of Air Distribution Products Division

1934 First contract between Barber Colman and “Industrieele & Handels Mij” Amsterdam

1982 BARCOL-AIR BV (The Netherlands) founded (100% subsidiary of Barber- Colman)

1987 Barber-Colman purchased by SIEBE Plc

1998 SIEBE merge with BTR : Invensys

2006 Barcol-Air BV purchased by HC Groep

Page 6: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

6

Introduction HC Groep

Integral supplier

Comfort, safety and an optimal living and working environment – the main goals for the HC Groep as an integral supplier. Either climate ceilings, ventilation, air treatment- or climate control, you will find the perfect solution within the HC Groep.

Versatile, high quality standards, flexible and customer-minded. Because of these high standards, consultants, architects and contractors have been calling upon the companies within the HC Groep.

Unity in diversity

The HC Groep consist of seven com-panies, each of them fully aware of the latest market requirements and in direct contact with business related partners.

The overview in the right pictures the different companies and their activities.

Combined strength

Constant attention to unity in the com-pany, excellent service and financial security makes the HC Groep a strong and reliable partner.

A unity, which pays close attention to the wishes and needs of the market. By operating together, the companies can combine their services like never before, offering you only the best available products and services.

The HC Groep combines decades of knowledge and experience. We are eager to share this knowledge with you. On top of this, we have our own climate room, in which full scale mock-ups can be constructed. Difficulties, which can occur during construction and/or com-missioning, can be prevented by perfor-ming climate room tests. The quality of products supplied by the HC Groep are guaranteed by a wide range of certifica-tions and attests of independent testing authorities. Thus consolidating the reliabi-lity of the products.

HC Groep Waalwijk

HC Holland Conditioning Chillers: • Heat pumps • Close Control Units • Dry coolers • Fan Coil Units

HC KP Climate ceilings: • Metal ceilings • Industrial ceilings • Plaster ceilings • Air climate ceilings

HC TN Air handling units: • 3 series • TB1 / T1 • Own coils • Renovation

HC PS Car park ventilation: • Ventilation systems • CO / LPG-detection • Fire detection • Switchboards

HC TS Stairwell Pressurization Systems • Passive & active systems • SMART technology • Fire detection • Control Panels

HC Groep Purmerend

HC RT Controls: • Building Management Systems • Energy management • Monitoring • Service and maintenance

HC Barcol-Air Air Distribution: • Grilles and diffusers • VAV and CAV Units • Chilled beams • Research and development

AIR DISTRIBUTION

controls

chillers

CHILLED CEILINGS

AIR HANDLING

Stairwell Pressurization Systems

AIR DISTRIBUTION

controls

chillers

CHILLED CEILINGS

AIR HANDLING

Stairwell Pressurization Systems

AIR DISTRIBUTION

controls

chillers

CHILLED CEILINGS

AIR HANDLING

Stairwell Pressurization Systems

AIR DISTRIBUTION

controls

chillers

CHILLED CEILINGS

AIR HANDLING

Stairwell Pressurization Systems

AIR DISTRIBUTION

controls

chillers

CHILLED CEILINGS

AIR HANDLING

Stairwell Pressurization Systems

AIR DISTRIBUTION

controls

chillers

CHILLED CEILINGS

AIR HANDLING

Stairwell Pressurization Systems

AIR DISTRIBUTION

controls

chillers

CHILLED CEILINGS

AIR HANDLING

Stairwell Pressurization Systems

Page 7: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

7

Single Source - Single Responsibility

HC TN• Air Handling Unit

HC Barcol-Air• (Induction) VAV system• Grilles & Diffusers

Holland Conditioning• Chiller

Holland Conditioning• Dry chiller

HC KP• Climate ceiling

HC Barcol-Air• Fan Coil Units• Grilles & Diffusers

HC RT• Controls

HC PS• Exhaust fans

Holland Conditioning• Fan Coil Units: (wall & floor model)

HC PS• Induction Fan (Car park ventilation)

HC Barcol-Air• Chilled Beam

HC TS• Overpressure system (staircase ventilation)

HC PS / HC RT /HC Barcol-Air• Overpressure system (staircase ventilation))

Page 8: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

8

Organisation

HC Barcol-Air Organisation Chart

Management

Marketing Financial Administration

HC Barcol-Air HC RT Controls

Domestic Procurement

Production

Product DevelopmentExport Logistics

Assembly

Engineering

Quality Controller

Sales Internal OperationsEngineering

ClimateRoom

Page 9: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

9

HC Barcol-Air Organisation Chart

Climate laboratory & Product development

Climate laboratory

The purpose of a full-scale climate laboratory test is to give the client, designer and consul-tant maximum security about the installation’s design, in an early stage. Especially when the design is completely new, not often used or when the building has specific characteristics, a climate laboratory test can prevent problems and delays during construction or even after commissioning.

HC Barcol-Air’s climate laboratory has a maximum floor space of approx. 8 x 8 meter with flexible positional walls and ceiling up to a height of 3.3 meter. To perform full-scale tests, the room is built with exact (actual) dimensi-ons. The climate façade simulates the outdoor conditions and can be cooled to simulate winter conditions and heated to simulate summer conditions. Uniquely this climate laboratory has two climate facades from bottom to ceiling, which enables testing of (complicated) corner rooms.

Mock-ups are not only built with actual dimen-sions but also façade, ceiling, furniture, floor covering, convectors and lightning can be built according to project specification. There is also the possibility of building special application rooms like hospital rooms, dealing rooms, labo-ratories and so on.

In the climate laboratory of HC Barcol-Air static tests are performed. This means that thermal conditions in- and outside the mock-up are equal; there is no transmission loss via walls, floor or ceiling.

Data Acquisition System

All measuring data is collected and proces-sed with labVIEW® supported, automatic Data Acquisition System. labVIEW® is a software program by National Instruments for virtual instrumentation.

Measuring robot

The most important part of the measuring system, in the actual size built mock-up, is the measuring robot with accurate air temperature

and velocity sensors which moves around the space. The height of the measuring sensors is according to NEN-ISO standards 0,1 – 0,6 – 1,1 and 1,7 meter above the floor. These heights represent ankles, bottom, trunk and head of the human body. The robot measures the area from floor to ceiling and from front to back of the test room. Extra sensors are mounted on the robot for other heights and different measuring areas to detect possible irregularities (for instance asymmetry) of the air pattern. Extra sensors are also mounted 5 cm below the ceiling to check the air pattern (Coanda effect) of the supply diffusers.

Fixed sensors

Besides the sensors on the measuring robot, there are also sensors mounted on fixed places for primary air temperature, supply air tempera-ture, air volume, reference room temperature, windowpane surface temperature (in- and out-side) and environment temperature.

Accuracy air velocity andtemperature sensors

The accuracy and response time of all sensors apply to the standards set in the ISO 7726 (1998). The temperature sensors have a relative accuracy of 0,1 ºC and a time constant of 2,3 seconds. The air velocity sensors have an accuracy of 0,014 m/s and a time constant of 0,03 seconds.

Page 10: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

10

Standards

The climate laboratory meets the mostrecent standards NEN-ISO 7726 and NEN-ISO 7730. The results of measure-ments and check of the air stream pattern and distribution is generally checked against DIN 1946, part 2. The calculated comfort

parameters are checked against NEN-ISO 7730. It is also possible to check the climate laboratory test results and comfort parameters against to specific project demands.

Presentation test results

Air temperature and velocity measuring results are presen-ted in both graphical and table format. The data acquisi-tion system has a unique cal-culation module to present real time not only air temperature and velocity but also the PMV (Predicted Mean Vote), PPD (Percentage People Dissatis-fied) and DR (Draft Rate). All displayed values are aver-age values per 100 seconds.

Reporting

After the climate laboratory test has beenfinished and discussed with the principal, acomplete and final report is made. This re-port describes in detail under which con-ditions and which specifications the test was performed. The measuring results and conclusion are a written proof of the perfor-mance of the tested installation concept. By recording all data and results accurately, the test can be reproduced.

Product development

Besides testing project specific installation concepts, the climate laboratory is used for product and system research and new

developments. One of HC Barcol-Air’s main competences

is project specific design of air distribution components or modification of standard products. These new products can be tested easily to check whether they apply to the set standards.

CFD simulations

Besides the climate laboratory HC Barcol-Air uses Computational Fluid Dynamics (CFD) simulation software to develop, design and test new products. This increases the speed of the development process.

Climate laboratory & Product development0.0 0.30.20.1

Air velocity [m/s] →

Section ---

Section D-D

Section C-C

Section B-B

Section A_A

0.250.150.05

0.0 0.30.20.1

Air velocity [m/s] →

Section ---

Section D-D

Section C-C

Section B-B

Section A_A

0.250.150.05

0.0 0.30.20.1

Air velocity [m/s] →

Section ---

Section D-D

Section C-C

Section B-B

Section A_A

0.250.150.05

Page 11: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

11

Acoustic reverberation room

Introduction

HC Barcol-Air has built a reverberation room for pre-design sound testing of products and systems. This enables HC Barcol-Air to test products and systems for thermal indoor climate as well as sound production and absorption.

Acoustic performance

The test at HC Barcol-Air is executed in a rever-beration room, which has a volume of 65 m³ and a reverberation time of 2.2 - 2.5 seconds.

Measurements are being executed through a cali-brated sound meter fabricated by Delta Ohm type HD2010, this can determine the reverberation time for each room/test set-up individually.

Measurement of inlet sound

The CAV/VAV/FCU will be set-up inside the reverberation room with the outlet connected to the opening towards the adjacent small room. This way a combination of the inlet sound together with the radiated sound will be measured.

Measurement of outlet sound

In this case the CAV/VAV/FCU will be placed in the small adjacent room with the outlet connected towards the reverberation room. Only discharge sound levels will be measured in this case.

Acoustic calculations

The measured sound levels will be corrected with the background noise and the reverberation time of the room, which will both be measured seperately.

The measured sound power levels for the mid ranges of frequency band 125 – 4,000 Hz and NR levels will be presented in table and graph form.

Page 12: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

12

Product overview

Circular single duct VAV terminal• Pressure independent • For individual room temperature control• Size 100 to 400• Single or double wall construction• Compact in size• Low leakage damper• High accurate airflow sensor (Flo-Cross®)• Quiet in operation• Optionally provided with sound attenuator and / or reheat coil

(hot water or electric)

Rectangular single duct VAV terminal• Pressure independent for large air volumes • For individual room temperature control• Size 200 x 150 to 2000 x 1000mm• Single or double wall construction• 350 mm installation length• Low leakage damper (optional)• High accurate airflow sensor (Flo-Cross®)• Quiet in operation• Optionally provided with sound attenuator and / or reheat coil

(hot water or electric)

Induction VAV terminal • Pressure independent • For comfortable air distribution in systems with high load variation• Size 100 to 400• Low leakage damper• High accurate airflow sensor (Flo-Cross®)• Very quiet in operation• Optionally provided with reheat coil (hot water or electric)• Provides savings in energy

VAV and CAV terminals

Type NA/NB

Type NK/NL

Type NV

VAV terminal with integrated sound attenuator• Pressure independent • For low noise requirements in high pressure or high velocity

systems• Size 100 to 400• Compact in size• Low leakage damper• High accurate airflow sensor (Flo-Cross®) • Very quiet in operation• Optionally provided with reheat coil (hot water or electric)

Type NS

Page 13: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

13

VAV and CAV terminals

Fan Powered VAV terminal • Pressure independent • Parallel and series type fan• For high downstream pressure drop• Small to extra large fan• High accurate air flow sensor (Flo-Cross®)• Optionally provided with sound attenuator and / or reheat coil

(hot water or electric) • Variable fan speed control optional

Type NY

Type NZ Dual duct VAV / CAV terminal• Pressure independent • For individual room temperature control• Size 100 to 400• Low leakage damper• High accurate airflow sensor (Flo-Cross®) • Constant airflow to the room• Quiet in operation• Optionally provided with sound attenuator and / or reheat coil

(hot water or electric)

By Pass VAV terminal • For constant primary air flow• Pressure dependent• Variable flow to the room• Size 100 to 400• Optionally provided with electric reheat coil• Optionally provided with high accurate airflow sensor (Flo-Cross®)

for pressure independent requirements.

Type NP

Page 14: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

14

Product overview

VAV and CAV terminals

Electric reheat coil• Factory fitted into the corresponding VAV or CAV terminal• Low air-side pressure loss• 230/240VAC/1-phase or 400/415VAC/3-phase power supply• Stage, PWM or thyristor control

Type N...E.. / N...F.. / N...G.. /N...H.. / N...J..

Hot water reheat coil

• Factory fitted into the corresponding VAV or CAV terminal • High heat exchange efficiency• Available in 1-, 2- or 4-row design• Low air side pressure drop

Type N...A.. / N...B.. / N...D..

Rectangular CAV pressure independent terminal• Pressure independent• Single wall or double wall • Size 150 x 100 to 600 x 600• Control accuracy ±10% • Factory set, saves commissioning time• Provision for on-site adjustment across the full volume scale• Quiet in operation

Type NM / NN

Circular CAV air volume control terminal• Pressure independent• Single wall or double wall • Size 80 - 400• Control accuracy ±10% • Factory set, saves commissioning time• Provision for on-site adjustment across the full volume scale• Quiet in operation• Optionally provided with sound attenuator and / or reheat coil

(hot water or electric)

Type NR / NT

Page 15: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

15

Rectangular sound attenuatorType ABH

Accessories

Circular sound attenuator, with or without core

Air volume measuring station (circular and rectangular)

Air volume measuring and control station(circular and rectangular)

Air volume measuring and pressure control station(circular and rectangular)

Type ABE / ABF

Type AEP / AER

Type AFQ / AFS

Type AHQ / AHS

Page 16: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

16

Fan Coil Unit • Horizontal or vertical application• With or without cabinet• Inlet sound attenuator with fresh air connection optional• Multiple circular outlets section optional• Extended and insulated drip tray• 2 pipe change-over or 4-pipe system• Electric heating coil optional

Multizone variable speed Fan Coil Unit • 2 nos. zones with 1 no. Fan Coil Unit• Saving energy by variable fan speed• No control valves required• Control by variable speed and bypass damper• Low noise fans with high efficiency, backward

curved fan blades• Electric heating coil optional

Fan Coil Units

Type FCU

Type FV/FW

Intelligent Fan Coil Unit for hotel application• 5-speed fan• Acces panel with integrated return air diffuser• 2 integrated halogen spotlights• 4-pipe / 2-pipe options• Drip tray with level detector and condensate drain• Filter dp switch• LONworks unitary controller • User interface• Panel detection switch and inspection light

Type FH

Product overview

Page 17: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

17

Chilled Beams

Fire Dampers

Active Chilled Beam • 2-pipe and 4-pipe coils• Model 300 or 600• Size 600, 1200, 1500, 1800, 2400 or 3000• Standard or high capacity coil• Optionally provided with adjustable nozzle settings• Optionally provided with radiant panels

Active Chilled Beam • High graded construction materials• Free choice in locating return-air diffuser• Minimum installation height• Esthetic lineair design• Limited visability in the ceiling• Optionally provided with drip tray

Type AIR-FIT®

Type AIR-TWIST®

Fire damper, circular. Rating 90 mins.

Fire damper, rectangular. Rating 90 mins.

Type FR90

Type FK90

Page 18: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

18

High capacity Jet-Flo diffuser with adjustable elements

Linear slot diffuser, adjustable air pattern

Linear Jet diffuserSpecial air flow pattern. Especially designed for use with chilled ceiling.

Transfer grille non-vision / light proof

Exposed circular duct section with integral linear slot diffuser

Transfer grille, sound proof

Diffusers and grilles

Type CLW

Type CSV

Type GCJ

Type GDZ

Type CAW

Type GGE

Grille, high induction

Type GHA

“Egg crate” diffuser

Type GLX / GHX

Page 19: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

19

Grille, aluminium construction single and double deflection

Grille, aluminium construction single deflection

Diffusers and grilles

Circular, high induction wall grille

Grille for circular duct mounting

Type GKB / GKD

Type GKM / GKN

Type GPA

Type GRA

Square perforated ceiling diffuser

Square perforated ceiling diffuser,for T-bar ceilings

Square perforated ceiling diffuser

Adjustable nozzle grille

Type PES

Type PET / POTO

Type PBS / PBT

Type GRQ / GOK

Page 20: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

20

Diffusers and grilles

Laminair downflow diffuser for hospital applications

Invisible diffuser, optimised for climate ceilings

Ceiling diffuser, lattice grid core

Type PHT

Type PSC

Type PXL / PXH

Perforated diffuser, V-shapedType PYH

Louvre face diffuser (square & rectangular)

Wall and window grille, linear fixed core, 0° / 15° deflection

Type TBW

High capacity, circular swirl diffuser with fully adjustable air pattern

Type VBG

Floor register, linear fixed core 0° / 15° deflection

Type TBV

Type SFQ / SFT

Page 21: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

21

Diffusers and grilles

Swirl diffuser with square face-plate and fixed, radial air pattern

Type VFT

Type VFK HC CLI-MATE® swirl diffuser

Circular louvre face diffuser with adjustable air pattern

Circular perforated / staircase diffuser

Type VJS

Type VPR

Circular supply & exhaust valve

Type VTA / VRA

Circular, perforated floor registerType VPV

Swirl diffuser with discharge cone and fixed, radial air pattern

Type VFC

Page 22: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

22

Product overview

Accessories

External weather louvre, aluminium or steel

Rectangular multi leaf air volume control damper (blades 50 mm)

Rectangular multi leaf air volume control damper (blades 100 / 165 mm)

Airturn and deflectrol

Type ACPZA / ACPZN

Type ADM

Type ADF / ADG

Type AA...

Page 23: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

23

Combined expertiseVAV and Controls

Plug & Play• Pre-fitted• Pre-wired• Pre-calibrated• Pre-tested

Flo-Cross® air flow sensor • High accuracy (better than 2,5%)• 24 test points• Centre-averaging signal• Amplifying wings• Aluminium construction with PP-connections• Low resistance• One-time diameter installation length

Benefits of VAV terminals with pre-fitted controls• Single source• Single responsibility• No coordination• No delays in deliveries• Single service responsibility• Open protocol: LonMark® / BACnet®

• Easy integration with any BMS

Compatible with any BMS SystemRoom Thermostat• Digital display• Set point adjustment• Actual temperature measurement• Programmable override button• Built-in CO2 sensor (optional)• Built-in humidity sensor (optional)

Flo-Cross®

• High accurate airflow sensor

DDC controller• Printed Circuit Board• Pressure transducer• Actuator• Communication protocol• Fully programmable

Damper blade• Linear control characteristic • Full shut-off seal• Low leakage

LonMark® (LON)

BACnet® ( BTL Certified)

Page 24: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

24

Introduction

Conventional VAV systems have proven in the past to be very efficient in provi-ding an optimal indoor climate. However the latest standard and requirements for energy efficiency and human comfort make it more and more difficult to design conventional VAV systems in new buil-dings. From an energy point of view, the minimum air volume could cause “cold air dumping” and lack of air movement in the room, resulting in occupants discomfort and a consequent decrease in producti-vity.

Induction VAV is the best solution to maintain proper air circulation and com-fort levels reducing the primary treated air to a very minimum (20% of maximum). Without the use of an additional fan, room air will be induced and the required norms for comfort will be achieved.

Induction VAV, the optimum indoor climate and energy efficient system

Supply Air

Primary Air

Induction Air

Induction Air

Benefits of induction VAV

• Capacity up to 200 W/m2 without loosing comfort• Cooling, heating and ventilation done by a single VAV terminal• Optimum in comfort• Pressure independent• Induction without use of a fan• No cold air dumping

• Energy conscious• Compact in size• Savings in primary ductwork• Low noise levels• Maintenance free• Standard VAV controller can be used• High accurate Flo-Cross® air flow sensor

Induction VAV helps to make your building GREEN

Page 25: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

25

Induction VAV References

Africa:Sudapet Sudan 250 unitsFlight Kitchen Addis Abeba 100 units

America’s:Belgrano Buenos Aires 600 unitsDCA Carabinieros Santiago de Chile 50 units

Europe:Ministry of Education The Hague 1700 units KPMG Langerhuizen Amsterdam 1700 units KPMG Marktstaete Rotterdam 1200 unitsHospital Meaux France 350 unitsBelcrowlaan, Gosselin Belgium 100 unitsOffice Complex Aldermaston 400 units Rank Xerox head office Welwyn 1200 unitsBritish Gas Reading 600 unitsOracle 5 building campus Reading 500 unitsGatwick airport Gatwick 100 units More London 150 unitsRose Court Southward London 600 units1 America SQ London 700 unitsMI6 building London 1500 unitsCanary wharf London 750 unitsWexham park London 800 unitsChannel 4 building London 400 units

Middle East:UAE Central Bank Abu Dhabi 300 units Ministry of Foreign Affairs Abu Dhabi 700 unitsTakreer Atheer HQ (ADNOC) Abu Dhabi 1200 units Financial Harbour Project Bahrain 1800 unitsInternational Insurance Tower Bahrain 600 units Financial City Main Gate Building Dubai 200 unitsMedia City Dubai 1000 units Shangri-La Hotel Dubai 200 units Flower Centre Airport Dubai 100 units Emaar Business Park Dubai 1800 unitsCity Hospital Dubai 800 unitsCultural Village Qatar 600 units West Bay Complex (Qtel tower) Qatar 400 unitsScience Technology Park Qatar 400 units Far East:ITE Simei Singapore 800 unitsNUS Business School Singapore 600 units HSBC Singapore 500 unitsNTU SPMS Singapore 500 unitsNUS University Town Singapore 150 unitsCathay Life Insurance Taipei 50 units

Asia Pacific:Latrobe, Melbourne Australia 250 unitsNAB House, Sydney Australia 150 unitsKeira Street, Wollongong Australia 100 units

Induction VAV, the optimum indoor climate and energy efficient system

Financial Harbour Bay - Bahrain

Page 26: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

26

Export reference projects (other)

Europe:

Gosselin Groep Belcrowlaan Belgium

C.H. Perigueux FranceCentre Hospitalier de Cannes FranceCHU Dupuytren Limoges FranceEOS Generali / Microsoft FranceGESEC Tours FranceHopital de Marmande FranceHopital Nord Marseille FranceHospitalier Cambrai FranceILOT Fonderies Nantes FranceLABO CEA Bst 328 FranceMaison Medicalede L’Estuai FranceUrgences Bichat-Paris France

Birra Peroni SpA, Roma ItalyPolo Chiurgico S. Orsola Italy

Cyta-Caramondani, Nicosia CyprusTasos Georgiou Opthalmology, Nicosia Cyprus

Ossolineum Museum Wroclaw Poland“In-Vitro” Clinic Hospital - Katowice Poland

Assembleia da Rep. Medicoe Portugal

AMZS Vransko SloveniaBDO accountancy SloveniaMasterline SloveniaSAVA Office SloveniaSava, Savica Hotel Park Slovenia

Porschezentrum Maienfeld Neubau SwitzerlandRadisson Airport Hotel Zurich SwitzerlandUBS AP6Z Basel SwitzerlandHermann AG Walzenhausen SwitzerlandManor Geneve SwitzerlandTSI COMANDO-SUDIO 1 SwitzerlandUNI-PHZ Luzern Switzerland

123 Buckingham Palace United Kingdom55 King William Street United Kingdom78-89 Uxbridge Road United Kingdom95 gresham street United KingdomBP County Hall London United KingdomChelsea Westminster Hospital United KingdomCisco (Emerging Markets) United KingdomCivil Just Centre Manchester United KingdomCutlers Court and Cutlers Exchange United KingdomEcex Unit 3 Thatcham United KingdomGSK House Brentford United KingdomHutton United KingdomKPMG Gold United KingdomMoody’s, 1 Canada Square United KingdomMore Plot 7 United KingdomMurdoch United Kingdom

NBC News United KingdomNIDO United KingdomNOA Aldermasten Phase II United KingdomOsnaburghstreet Bldg B United KingdomP4593 IBM North Harbour United KingdomParkerm.s. Victoria House United KingdomPhoenix United KingdomRegents Place Osnaburgh United KingdomRose Court United KingdomS.Matthew Heathrow Airport United KingdomSchlumberger United KingdomStockley Park London United KingdomTeddington School United KingdomThe Walbrook/Corner Bond C United KingdomTratton House United KingdomTwo Kingdom Street United KingdomUniversity of Reading United KingdomWestminster College United KingdomWSCC County Hall United Kingdom

Barcap - London - UK

Page 27: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

27

Middle East:

Bahrain Financial Harbour BahrainBahrain Stock Exchange BahrainBapco PR Office BahrainBMSPO BahrainMarriott Exclusive Apartments BahrainTrust Tower Stock Exchange Bahrain

HCL Technologies Ltd IndiaAreva IndiaTarget IndiaMission Pharmaceuticals IndiaNokia Telecom IndiaPilot Training Facility IndiaInfosys IndiaCisco IndiaIntuit IndiaNorth Operation Services IndiaNorthern Trust India

Hotel Jordan

Bosicor Office PakistanForeign Office Islamabad PakistanPTET Tower Pakistan

Dialysis Center QatarDiwan Ameri QatarGrand Hyatt Hotel Doha QatarCultural Village QatarNew Western District Hospital Pack. 1&2 QatarQatar Invenstment Authority QatarQatar Petroleum HQ QatarEmergency Safety College QatarQP New training centre Qatar

Al Mas Tower United Arab EmiratesAl Raha Britisch School United Arab EmiratesAl Zahra Hospital United Arab EmiratesBay Gat Tower United Arab EmiratesBurj Dubai Business Hub United Arab Emirates Commercial Bldg Plot C-18 United Arab EmiratesConst. Laboratory & Safety United Arab EmiratesCruise Term. & Municipalit United Arab EmiratesDafza Office Building W7 United Arab EmiratesDanet Holiday Inn Hotel United Arab EmiratesDental Hospital United Arab EmiratesDown Town Jebel Ali - Limitless offices United Arab EmiratesGMG HQ United Arab EmiratesHamdan Villa United Arab EmiratesHarvard Medical School United Arab EmiratesHH Crown Prince Dewan United Arab EmiratesHSBC-Abu Dhabi United Arab EmiratesIbis Hotel & Offices United Arab EmiratesLandmark Place United Arab EmiratesMunicipality Office Dubai United Arab EmiratesNad al Hamar Health Centre United Arab EmiratesNon Process Building at GASCO Asab United Arab EmiratesProject 544 United Arab Emirates

Export reference projects (other)

Limitless offices downtown Jebel Ali - Dubai - UAE

Mubadala HQ - Abu Dhabi - UAE

Lahore Airport - Lahore - Pakistan

Navigation Tower - Doha - Qatar

Page 28: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

28

Export reference projects

QC Laboratory United Arab EmiratesRaceday Hotel United Arab EmiratesStandard Chartered Bank United Arab EmiratesTakreer Atheer United Arab EmiratesThe Show Village United Arab EmiratesYas Island, Hotel Rotana United Arab Emirates

Far East and Asia Pacific:

485, Latrobe Melbourne AustraliaGreenfell street AustraliaKeira Street, Wollongong AustraliaKing William Str. Australia AustraliaLatrobe Australia AustraliaNAB House, Sydney Australia

BDO Tower Makati PhilippinesCitibank Tower Makati PhilippinesConvergys PhilippinesGT Tower MakatiC PhilippinesHSBC The Fort PhilippinesJG Summit Philippines Lexmark Cebu PhilippinesNuComm Transcom PhilippinesOakwood Hotel Makati PhilippinesOne-E Com Pasay PhilippinesPbrom Tower Makati PhilippinesWynsum Tower Ortigas PhilippinesBritish Embassy PhilippinesSt. Luke Hospital Philippines

Citibank SingaporeNTU SPMS SingaporeSingapore Free Port SingaporeNUS Business School SingaporeITE Simei Town SingaporeNUS Univesity ERC SingaporeBio Research Centre (BRC phase 2) SingaporeNovena Hospital SingaporeBaxter Singapore

Academia Sinica Genomics Research TaiwanPou Chen headquarters building TaiwanY.S.P. GROUP ANTIBIOTICS PLANT TaiwanYanming Hospital TaiwanMazu Hospital TaiwanDunan Building Taiwan

North America BOG Surinam

Cornell University USASouth-end Elementary School USATorrington City Hall USAWestern New England College USA

South America

Belgrano ArgentinaDCA Carabinieros Chile

Cathay Life Insurance - Taipei - Taiwan

South End Elementary School - Southington - USA

One E-com Centre - Manilla - Philippines

Page 29: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

29

Distributors / partners

EuropeReliance Engineering Services Ltd. Nicosia Cypruswww.reliance.com.cy

MWH Barcol-Air France Cergy Pontoise Cedex Francewww.mwh.ch

Rafn Jensson Mechanical Engineers Reykjavik Icelandwww.rj.is

Coolair Ltd. Dublin Irelandwww.coolair.ie

Officine Volta S.p.A. Bologna Italywww.officinevolta.it

AHI Carrier Moscow Russiawww.ahi-carrier.ru

Vavtar Inženiring d.o.o. Ljubljana Sloveniawww.vavtar.si

Hiensch Engineering AB Stockholm Swedenwww.hiensch.se

MWH Barcol-air AG Stäfa Switzerlandwww.mwh.ch

Alarko-Carrier Istanbul Turkeywww.alarko-carrier.com.tr

Barcol-Air UK Ltd. Bath United Kingdomwww.barcol-air.co.uk

North and South AmericaCermac Air-Technik SRL Buenos Aires Argentinawww.cermac-arg.com.ar

Klima Santiago Chilewww.klima.cl

Barcol-Air Ltd. Oxford USAwww.barcolair.net

Page 30: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

30

Distributors / partners

Middle East Almoayyed Air Conditioning Manama Bahrainwww.almoayyedcg.com

ACE Supplies & Trading Co. Amman Jordanwww.ace-jordan.com

Yusuf A. Alghanim & Sons WLL Safat Kuwaitwww.alghanim.com

Maalouf Trading and Contracting S.A.L. Beirut Lebanonwww.maalouftc.com

Dan International LLC Muscat Omanwww.danwayllc.com

Shahjan Trading Company W.L.L Doha Qatarwww.shahjan.com

Dynamic Technology Supplies Co. Ltd. Jeddah Saudi Arabiawww.dtsaudi.com

MTTS Jeddah Saudi Arabiawww.mtts.com

Danway LLC Dubai United Arab Emirateswww.danwayllc.com Northern Emirates

Bahri & Mazroei Technical Systems Co. (LLC) Dubai United Arab Emirateswww.bmtconline.biz Northern Emirates

Dutco Tennant LLC Dubai United Arab Emirateswww.ductcotennant.com Northern Emirates

Independent Technical Solutions LLC Dubai United Arab EmiratesDealer HC PS (Car Park Ventilation)

NG Global Dubai United Arab Emirateswww.ngglobal.net

Al Taqa Equipment Est. Abu Dhabi / Al Ain United Arab Emirates www.altaqaequipments.com

Sibca Abu Dhabi / Al Ain United Arab Emirateswww.sibca.com

Page 31: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air - 2013Changes w/o notice or obligation.

31

Middle East Almoayyed Air Conditioning Manama Bahrainwww.almoayyedcg.com

ACE Supplies & Trading Co. Amman Jordanwww.ace-jordan.com

Yusuf A. Alghanim & Sons WLL Safat Kuwaitwww.alghanim.com

Maalouf Trading and Contracting S.A.L. Beirut Lebanonwww.maalouftc.com

Dan International LLC Muscat Omanwww.danwayllc.com

Shahjan Trading Company W.L.L Doha Qatarwww.shahjan.com

Dynamic Technology Supplies Co. Ltd. Jeddah Saudi Arabiawww.dtsaudi.com

MTTS Jeddah Saudi Arabiawww.mtts.com

Danway LLC Dubai United Arab Emirateswww.danwayllc.com Northern Emirates

Bahri & Mazroei Technical Systems Co. (LLC) Dubai United Arab Emirateswww.bmtconline.biz Northern Emirates

Dutco Tennant LLC Dubai United Arab Emirateswww.ductcotennant.com Northern Emirates

Independent Technical Solutions LLC Dubai United Arab EmiratesDealer HC PS (Car Park Ventilation)

NG Global Dubai United Arab Emirateswww.ngglobal.net

Al Taqa Equipment Est. Abu Dhabi / Al Ain United Arab Emirates www.altaqaequipments.com

Sibca Abu Dhabi / Al Ain United Arab Emirateswww.sibca.com

Distributors / partners

Far East and Asia Pacific Air Con Serve Pty. Ltd. Adelaide Australiawww.airconserve.com.au

Controlworks Sydney Australiawww.controlworks.com.au

Xebec Trading Services Dhaka Bangladesh

NG Solutions Pvt. Ltd. Chennai Indiawww.ngglobal.net

Carrier Race Technologies Pvt. Ltd. Chennai Indiawww.carrierrace.com

PT Barcol-Air Jakarta Indonesia

Instrumentation & Management Systems Karachi Pakistanwww.ims.com.pk

Air Filters Philippines Inc. Manila Philippines

Barcol Air Engineering Pte Ltd Singapore Singaporewww.barcolair.com

TEA Seoul South Koreawww.te-a.kr

Southern Automation Systems (Pvt) Ltd. Colombo Sri Lankawww.saslanka.com

Barcol Industries Inc. Taipei Taiwanwww.barcol.com.tw

Page 32: HC BARCOL-AIR COMPANY PROFILE · 2013. 11. 14. · HC Barcol-Air - 2013 Changes w/o notice or obligation. 4 Company introduction Mission statement HC Barcol-Air is specialised in

HC Barcol-Air

P.O. Box 283

1440 AG | Purmerend - the Netherlands

T +31 (0)299 689 300 | F +31 (0)299 436 932

E [email protected] | I www.hcgroep.com

HC Barcol-Air is part of HC Groep