2
Specifications 1 HC12-100 M8 (12V100Ah) HC12-100 M8 – Updated: 29.09.2021 Specifications subject to change without notice. Nominal Voltage 12V Nominal Capacity 108.6Ah (C 20 , 1.75V/cell) Approx. Weight 32kg Terminal M8 Container Material ABS UL94 HB (Optional: V0) Rated Capacity (25°C) 108.6Ah/5.43A, 20hr, 1.75V/cell 107.0Ah/10.7A, 10hr, 1.75V/cell 87.5Ah/17.5A, 5hr, 1.75V/cell 85.8Ah/28.6A, 3hr, 1.60V/cell 65.7Ah/65.7A, 1hr, 1.60V/cell Max. Discharge Current 900A (5s) Internal Resistance Approx. 5.0mΩ Operating Temp. Range Discharge: -15~50°C Charge: 0-40°C Storage: -15~40°C Nominal Oper. Temp. R. 25±3°C Cycle Use Initial Charging Current less than 30.0A. Voltage 14.4V~14.7V at 25°C. Temperature Coefficient -30mV/°C. Standby Use Initial Charging Current less than 30.0A. Voltage 13.5V~13.8V at 25°C Temp. Coefficient -20mV/°C Capacity affected by Temp. 40°C 103% 25°C 100% 0°C 86% Self Discharge HC batteries may be stored for up to 6 months at 25°C and then a freshening charge is required. For higher temperatures the time interval will be shorter. Cycle Life Approx. 650 Cycles at 50% DOD Dimensions M8 Terminal Unit: mm [inches] Electric tools Vehicle in place of walking Lawn mowers Golf trolleys Portable apparatus, lights and instruments Electric toys Certificates Applications MH61574 · ISO 9001 Conform to IEC60896-21&22 AGM-Technology Maintenance Free -15°C to +50°C Recyclable Extra Cycle Stability High Cycle Type Reha Stairlifts Portable power Wheelchairs Medical equipments Wind/Solar energy Electric boats Caravan Wind/Solar Energy Caravan 16 5 M8 330±1 171±1 264±5

HC12-100 M8 AGM-Technology Maintenance Free Extra Cycle

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: HC12-100 M8 AGM-Technology Maintenance Free Extra Cycle

Specifications

1

HC12-100 M8(12V100Ah)

HC12-100 M8 – Updated: 29.09.2021Specifications subject to change without notice.

Nominal Voltage 12VNominal Capacity 108.6Ah (C20, 1.75V/cell) Approx. Weight 32kg Terminal M8Container Material ABS UL94 HB (Optional: V0)Rated Capacity (25°C) 108.6Ah/5.43A, 20hr, 1.75V/cell 107.0Ah/10.7A, 10hr, 1.75V/cell 87.5Ah/17.5A, 5hr, 1.75V/cell 85.8Ah/28.6A, 3hr, 1.60V/cell 65.7Ah/65.7A, 1hr, 1.60V/cellMax. Discharge Current 900A (5s)Internal Resistance Approx. 5.0mΩOperating Temp. Range Discharge: -15~50°C Charge: 0-40°C Storage: -15~40°C

Nominal Oper. Temp. R. 25±3°CCycle Use Initial Charging Current less than 30.0A. Voltage 14.4V~14.7V at 25°C. Temperature Coefficient -30mV/°C.Standby Use Initial Charging Current less than 30.0A. Voltage 13.5V~13.8V at 25°C Temp. Coefficient -20mV/°CCapacity affected by Temp. 40°C 103% 25°C 100% 0°C 86%Self Discharge HC batteries may be stored for up to 6 months at 25°C and then a freshening charge is required. For higher temperatures the time interval will be shorter.Cycle Life Approx. 650 Cycles at 50% DOD

Dimensions

M8 Terminal Unit: mm [inches]

Electric toolsVehicle in place of walkingLawn mowersGolf trolleysPortable apparatus, lights and instrumentsElectric toys

Certificates

Applications

MH61574

· ISO 9001 Conform to IEC60896-21&22

AGM-Technology Maintenance Free -15°C to +50°C RecyclableExtra Cycle Stability

High Cycle Type Reha Stairlifts

Portable powerWheelchairsMedical equipmentsWind/Solar energyElectric boatsCaravan

Wind/Solar Energy Caravan

1 6

5

M8

330±1 171±1 264±5

Page 2: HC12-100 M8 AGM-Technology Maintenance Free Extra Cycle

2 HC12-100 M8

1.60V/cell1.65V/cell1.70V/cell1.75V/cell1.80V/cell

End Point 5min284367345314276

10min

257243226209188

15min197189179164145

30min102.397.591.984.774.9

1h65.763.861.357.251.5

3h28.627.726.625.023.5

5h18.718.518.017.516.7

10h11.411.310.910.710.6

20h5.745.645.555.435.35

Specifications subject to change without notice.

Constant Current Discharge (Amperes) at 25°C

Constant Power Discharge (Watts/cell) at 25°C

Discharge Characteristics (25°C) Float Charging Characteristics (25°C)

Temperature Effects in Relation to Battery Capacity Cycle Service Life in Relation to Depth of Discharge

1.60V/cell1.65V/cell1.70V/cell1.75V/cell1.80V/cell

End Point 5min664.82632.80599.62564.50527.50

10min

473.50451.83428.66428.66426.67

15min364.33349.18332.83314.83296.00

30min203.50196.50188.50180.02171.00

1h131.00129.01126.50126.17120.52

3h57.1255.8354.5052.7950.83

5h37.8337.1836.5035.5234.02

10h23.3223.0222.3321.5120.50

20h11.8211.6211.4311.2511.08

Self Discharge Characteristics Temperature Effects on Float Life

oTemperature ( C)

oTemperature ( C)

1 3 5 10 20 30 60 2 3 5 10 20min h

Discharge time

(V)

12.0

9.6

0

200A 100A 65.2A

26.6A17.4A 9.50A

Charging time (hours)

Cha

rged

Volu

me

(%)

Cur

rent

(XCA)Vo

ltage

(V)

15.0

14.0

13.0

12.0

11.0

0.25

0.20

0.15

0.10

0.05

00 2 4 6 8 10 12 14 16 18 20

140

120

100

80

60

40

20

0Charging Current

Charge Voltage

Charged Volume

120

100

80

60

40

20

-20 -10 0 10 20 30 40 50

Cap

acity

(%)

0.05C

0.1C

02C.

1.0C

2.0C

Number of cycles (cycles)

Cap

acity

(%)

100

90

80

70

60

50

400 2 4 6 8 10 12 14 16 18 20

Storage time: months

Cap

acity

(%)

2.30V/Cell

0

15

10 20 30 40 50

5

10

D

120

100

80

60

40

20

0200

400

600

800

1000

1200

1400

1600

100% D.O.D. 50% D.O.D. 30% Depth of discharge