Product Description Pipe Size
Type Series Colormm 20 25 32 40 50 63 75 90 110 160 200 250 315 355 600 800
in 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 6 8 10 12 14 24 30
Primers PP32 Purple
Cleaners C32 Clear
Specialty AT32 Clear
Medium Body
G32 Gray
Regular Body
CMT Clear
• Economically Formulated
• Fast Setting
• Wide Range of Applications
• Independently and Laboratory Tested
PVC Cement
Centaur East Division635 Northwest Enterprise Dr.Port St. Lucie, FL 34986ph: 772.344.9436
Scan for PVC Website
Choosing The Right Product
For Assistance with selecting the right Centaur product for your application, please refer to the chart below.
LegendSchedule 40
Schedule 80
AVERAGE NUMBER OF JOINTS PER QUART
PIPE DIAM-ETERS
NUMBER OF JOINTS
1/2"20mm
350
3/4"25mm
300
1"32mm
200
1-1/2"50mm
120
2"63mm
80
3"90mm
50
4"110mm
40
6"160mm
20
8"200mm
6
10"250mm
3
12"315mm
2
14"380mm
1
18"450mm
1/2
ASTM is a globally recognized leader in the development and delivery of international voluntary consensus standards
ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence.
NSF International is an organization that provides standards development, product certification, auditing, education and risk management for public health and safety.
Uniform Plumbing Code (UPC) is a model code developed by the International Association of Plumbing and Mechanical Officials (IAPMO) to govern the installation and inspection of plumbing systems as a means of promoting the public's health, safety and welfare
Low VOC: Volatile Organic Compounds
Organic chemical compounds with significant vapor pressures and which can affect the environment and human health.
Centaur PVC solvent cement is made with the highest quality materials and meets or exceeds ASTM SPEC. D 2564. All information provided is based on our laboratory testing, independent laboratory test results, and actual field experience. Properly used, this material will perform in ac-cordance with applicable standards listed below.
High Standards
DIRECTIONS1. Apply pipe cleaner with dauber or suitable applicator to inside of fitting
and outside pipe diameter. WARNING: Use appropriate size dauber or
larger applicator if necessary.
2. Wipe off with clean, dry cloth.
3. Apply Centaur’s Primer and Cement as instructed on the label.
LIMITED WARRANTY: Manufacturer’s only obligation shall be to replace such
quantities of the product proven to be defective. Return to manufacturer for
free replacement.
PRIMER FACILITATES AND STREGTHENS JOINING.NOT TO BE USED ON ABS OR THIN-WALLED PVC PIPE AND FITTINGS.FOR USE IN POTABLE WATER, SEWER AND DWV.APPLICATION TEMP: 32°F TO 110°F (0°C TO 43°C).STORAGE TEMP: 40°F TO 100°F (5°C TO 38°C).
10. Follow all recommended procedures for joining PVC pipe and fittingsas stated in ASTM SPEC. D 2855.
• Effectively Removes Oils, Dirt, Grease & Other Foreign Matter• For PVC, CPVC and ABS Pipe & Fittings
This cement is made with the highest quality materials and meets or exceeds ASTMSPEC. D 2564. All information provided is based on our laboratory testing, independent laboratory test results, and actual field experience. Properly used, this material will performin accordance with applicable standards. Since we are unable to control conditions for whichthe product is being used, our only obligation will be the replacement of the cement.
CENTAUR MANUFACTURING635 NW Enterprise Dr. Port St Lucie, FL 34986
ph. 772-344-9436 • www.centaurpvc.com
WARNING: EXTREMELY FLAMMABLEDO NOT USE NEAR HEAT, SPARKS OR OPEN FLAME.
STORE IN COOL, WELL VENTILATED AREA.May be absorbed through the skin. Harmful or fatal if swallowed.
Use with adequate ventilation. Avoid prolonged breathing of vapors.Avoid contact with eyes or skin. Keep container tightly capped when not in use.
KEEP OUT OF REACH OF CHILDREN - FIRST AID:EYES: Flush thoroughly with water for at least 15 minutes. Call physician immediately.
INTERNAL: Do not induce vomiting. Call physician immediately.EXTERNAL: Wash thoroughly with soap and water and
apply a skin lotion. Wash clothing before re-use.
Max VOC per SCAQMD 1168/316A: 510G/LLow VOC products may be suitable or required for use on projects
following green building codes or rating systems.
READ THE FOLLOWING BEFORE USING: Contains Tetrahydrofuran, CAS# 109-99-9; Methyl Ethyl Ketone,CAS# 78-93-3; Cyclohexanone, CAS# 108-94-1 and Acetone, CAS# 67-64-1.
WARNING: EXTREMELY FLAMMABLE.HARMFUL OR FATAL IF SWALLOWED.ANTIDOTE: IN CASE OF INGESTION,
DO NOT INDUCE VOMITING.CALL A PHYSICIAN IMMEDIATELY.
STOCK CODE# CMT1QNET CONTENTS QUART - 32 FL. OZ. (947 ml)
Scan for MSDS Sheet
R
PW, DWV, SWLowVOC
CM
T1Q
CU
TC
LEA
NP
RIM
EC
EM
EN
TA
SS
EM
BLE
C32 CENTAUR PIPE CLEANER
PVC CLEANER
DIRECTIONS1. Prepare pipe according to the instructions shown on the images.
2. Apply a liberal coat of Purple Primer on both fitting socket and pipe end.
3. Apply solvent cement while primer is wet. Warning: Use appropriate size
dauber or larger applicator if necessary.
4. For large diameter pipe, a second coat of primer may be necessary.
HANDLE WITH CARE Please note that purple Primer/Cleaner will stain most
materials and cannot be removed.
LIMITED WARRANTY: Manufacturer’s only obligation shall be to replace such
quantities of the product proven to be defective. Return to manufacturer for
free replacement.
PRIMER FACILITATES AND STRENGHTENS JOINING.NOT TO BE USED ON ABS OR THIN-WALLED PVC PIPE AND FITTINGS.FOR USE IN POTABLE WATER, SEWER AND DWV.APPLICATION TEMP: 32°F TO 110°F (0°C TO 43°C)STORAGE TEMP: 40°F TO 100°F (5°C TO 38°C)
10. Follow all recommended procedures for joining PVC pipe and fittingsas stated in ASTM SPEC. D 2855.
• Fast Set• For PVC & CPVC Pipe and Fittings• All Sizes• All Schedules• Meets ASTM F-656
This cement is made with the highest quality materials and meets or exceeds ASTMSPEC. D 2564. All information provided is based on our laboratory testing, independent laboratory test results, and actual field experience. Properly used, this material will performin accordance with applicable standards. Since we are unable to control conditions for whichthe product is being used, our only obligation will be the replacement of the cement.
CENTAUR MANUFACTURING635 NW Enterprise Dr. Port St Lucie, FL 34986
ph. 772-344-9436 • www.centaurpvc.com
WARNING: EXTREMELY FLAMMABLEDO NOT USE NEAR HEAT, SPARKS OR OPEN FLAME.
STORE IN COOL, WELL VENTILATED AREA.May be absorbed through the skin. Harmful or fatal if swallowed.
Use with adequate ventilation. Avoid prolonged breathing of vapors.Avoid contact with eyes or skin. Keep container tightly capped when not in use.
KEEP OUT OF REACH OF CHILDREN - FIRST AID:EYES: Flush thoroughly with water for at least 15 minutes. Call physician immediately.
INTERNAL: Do not induce vomiting. Call physician immediately.EXTERNAL: Wash thoroughly with soap and water and
apply a skin lotion. Wash clothing before re-use.
Max VOC per SCAQMD 1168/316A: 510G/LLow VOC products may be suitable or required for use on projects
following green building codes or rating systems.
READ THE FOLLOWING BEFORE USING: Contains Tetrahydrofuran, CAS# 109-99-9; Methyl Ethyl Ketone,CAS# 78-93-3; Cyclohexanone, CAS# 108-94-1 and Acetone, CAS# 67-64-1.
WARNING: EXTREMELY FLAMMABLE.HARMFUL OR FATAL IF SWALLOWED.ANTIDOTE: IN CASE OF INGESTION,
DO NOT INDUCE VOMITING.CALL A PHYSICIAN IMMEDIATELY.
STOCK CODE# CMT1QNET CONTENTS QUART - 32 FL. OZ. (947 ml)
Scan for MSDS Sheet
R
PW, DWV, SWLowVOC
CM
T1Q
CU
TC
LEA
NP
RIM
EC
EM
EN
TA
SS
EM
BLE
PP32 CENTAUR PURPLE PRIMER
PVC PRIMER
Centaur PVC offers a wide range of PVC solvents for all your material joining
needs. We have teamed up with one of the countries leading PVC solvent
manufacturers to bring you another quality product line. All of our PVC
Solvents, Primers, and Cleaners meet or exceed industry standards and are
produced under some of the strictest quality control measures in the market.
From random sample testing to cap torque verification, we pride ourselves
on manufacturing only the highest quality products. The CMT series of
solvent cement will allow for the joining of pipe up to 6” (non-pressure), while
the competitors only go up to 4” (non-pressure). Centaur cement is also
environmentally friendly and only uses products that are Low VOC (Volatile
Organic Compound), which makes us the primary choice for any DIY green
projects and LEED projects. A newly added addition to our line is the AT32
an “all temperature” cement that allows for application in climates from
-17°F to 120°F while still being able to join 6” (non-pressure) pipe.
Centaur PVC
Centaur PVC East ph:772.344.9436 · www.centaurpvc.com Centaur PVC East ph: 772.344.9436 · www.centaurpvc.com
» Our most popular selling PVC cement. » Fast Set Time » Up to 4" - Sched. 40 (Pressure) Up to 6" - Sched. 40 (Non Pressure) » May be used for gas, conduit and other pressure & non pressure applications » Application Temp: 32°F to 110°F · Store Temp: 40° to 100°F » Viscosity: Min 90 cps @ 73°F · Max VOC per SCQMD 1168/316A: 510G/L » Not for scheldule 80 » Performance Standards ASTM D-2564 » Hydrostatic Burst Strength 2 Hour @ 73 ° 400 PSI » Lap Shear Strength 2 Hours - 250 PSI 16 Hours - 500 PSI 72 Hours - 900 PSI » Average 3 Year Shelf Life - Unopened Can
STOCK CODE# CMT05PNET CONTENTS ½ PINT - 8 FL. OZ. (237 ml)
CM
T05
P
C32 Centaur Pipe Cleaner
» Activation Time - Fast Acting » Effectively removes oils, dirt, grease and other foreign matter » For all types of PVC , CPVC, ABS pipes & fittings all schedules & sizes » Cleaning of pipes is highly recommended prior to cementing » Application temp: 32°F to 110°F · Storage Temp: 40°F to 100°F » Max VOC per SCAQMD 1168/316A: 550G/L » Average 3 Year Shelf Life - Unopened Can
PP32 Centaur Purple Primer
» Activation Time - Fast Acting » Meets ASTM standard F-656 » Use of primer is recommended for all schedules & sizes » Application Temp: 32°F to 100°F · Storage Temp: 40°F to 100°F » Max VOC per SCAQMD 1168/316A:550G/L » CAUTION: Do not use on ABS or thin-walled PVC pipes & fittings » All Schedules All Sizes » Average 3 Year Shelf Life - Unopened Can
CH
EM
ICA
L B
RE
AK
DO
WN
A Formula That SticksPVC solvent cement contains methyl ethyl ketone, which breaks down the top layer of PVC on both the pipe and fitting to be cemented. It also contains PVC resin, which is essentially liquid PVC. Once the solvent breaks down the PVC pipe and fitting, the resin moves into the gaps between the PVC molecules. The solvent then evaporates and the two pieces of PVC are fused together permanently.Another important factor to take into consideration, is the size of the pipe. With larger pipe you need more resin to act as a filler. If the PVC solvent cement doesn't have the right amount of resin it can leave gaps when sealing and eventually fail. Centaur PVC Cement is the superior choice for top of the line electricians.
G32 Centaur Medium Bodied Gray Glue
» Set Time Medium » May be used for gas, conduit and other pressure & non pressure applications » Application Temp: 32°F to 110°F · Store Temp: 40°F to 100°F » Viscosity: Min 500 cps @ 73°F · Max VOC per SCAQMD 1168/316A: 510G/L » Up to 8" - Sched 40 & 80 (Pressure) Up tp 10" - Sched » Performance Standards ASTM D-2564 » Hydrostatic Burst Strength 2 Hours @73° 400 PSI » Lap Shear Strength 2 Hours - 250 PSI 16 Hours - 500 PSI 72 Hours - 900 PSI » Average 3 Year Shelf Life - Unopened Can
100°F
100°F
100°F110°F
120°F
32°F
32°F
32°F32°F
-17°F
6" Pressure to 14" Non-Pressure
4" Pressure to 6" Non-Pressure
½ Pint · CMT05P Pint · CMT1P
Quart · CMT1Q Gallon · CMT1G
Quart · C32
Quart · PP32
Quart · G32
Quart · AT32
AT32 Centaur All Temperature Cement
» Fast Set Time » Ideal for any climate and all seasons. » May be used for gas, conduit and other pressure & non pressure applications » Application Temp: -17°F to 120°F · Storage Temp: 40°F to 100°F » Viscosity: Min 500 cps @ 73°F · Max VOC per SCAQMD 1168/316A: 510G/L » Up to 6" - Sched. 40 & 80 (Pressure) Up to 8" - Sched. 40 & 80 (Non Pressure) » Performance Standards ASTM D-2564 » Hydrostatic Burst Strength 2 Hours @73° 400 PSI » Lap Shear Strength 2 Hours - 250 PSI 16 Hours - 500 PSI 72 Hours - 900 PSI » Average 3 Year Shelf Life - Unopened Can
6" Pressure to 8" Non-Pressure
Primers & Cleaners
CMT Series
PVC Glue
Scan for MSDS Sheet
Scan for MSDS Sheet
Scan for MSDS Sheet
Scan for MSDS Sheet
Scan for MSDS Sheet
DIRECTIONSSTIR OR SHAKE BEFORE USING.1. Cut pipe square with hand saw or pipe cutter and remove burrs from inside and outside diameters.2. Clean pipe and fitting socket with Centaur Pipe Cleaner. Wipe off with a clean,dry cloth.3. Check dry fit. Pipe should easily go 1/3 of the way into fitting. Use Centaur Primer. Primer will penetrate quickly for better bond.4. Apply a thin coat of cement into socket and a full even coat to pipe.WARNING: Use appropriate size dauber or larger applicator if necessary. Do not puddle cement in socket fitting.5. Engage pipe into fitting with slight twisting motion. Be sure pipe is bottomed into fitting. Hold pipe and fitting for 30 seconds. Wipe off excess cement.6. Allow cement to cure before pressurizing pipe7.As stated in ASTM D2855, when installing thin walled bell end pipe, do not apply an excess of cement in the bell socket.
APPLICATION TEMP: 32°F TO 110°F (0°C TO 43°C).STORAGE TEMP: 40°F TO 100°F (5°C TO 38°C).
LIMITED WARRANTY: Manufacturer’s only obligation shall be to replace such quantities of the product proven to be defective. Return to manufacturer for free replacement.
DIRECTIONS1. Cut the pipe square and remove all burrs.2. Check fitting of pipe. If too loose or too tight, pipe should not be used. Ideal fitbetween pipe & fitting before cementing allows pipe to enter to full depth of socketeasily.3. Remove all dust, moisture, grease, oil and any other foreign material from pipe and fitting. Clean pipe an fitting with CENTAUR CLEANER andCENTAUR PURPLE PRIMER. While surface is still damp with primerapply cement as follows. 4. Apply enough cement uniformly to pipe & fitting to form a bead of cement atoutside end of pipe. Prevent excess cement from forming on bare inside walls of pipe.5. Brush cement generously on the outside of pipe to depth of fitting. Do not thin cement with primers or cleaners.6. Immediately after cement is applied, insert pipe to bottom of socket, using a quarter twisting motion, and hold in place 30 seconds until cement sets. Assemble parts QUICKLY. If cement is not fluid, recoat both parts and repeat procedure.7. Remove excessive cement with a dry cloth only.8. Allow about 30 minutes for good handling strength. Cure time before testing depends on size, fit, temperature and pressures. Referto ASTM SPEC. D 2855, for recommended set and cure time.9. Keep container closed at all times when not using to avoid moistureabsorption and vapor losses. Keep cement from freezing.10. Follow all recommended procedures for joining PVC pipe and fittingsas stated in ASTM SPEC. D 2855.
• Medium Set• Schedule 40 & 80 upto 8” Dia. Pressure,10” Dia. Non Pressure• For Potable Water, DWV & Sewer Applications• Meets ASTM D-2564
This cement is made with the highest quality materials and meets or exceeds ASTMSPEC. D 2564. All information provided is based on our laboratory testing, independent laboratory test results, and actual field experience. Properly used, this material will performin accordance with applicable standards. Since we are unable to control conditions for whichthe product is being used, our only obligation will be the replacement of the cement.
CENTAUR MANUFACTURING635 NW Enterprise Dr. Port St Lucie, FL 34986
ph. 772-344-9436 • www.centaurpvc.com
WARNING: EXTREMELY FLAMMABLEDO NOT USE NEAR HEAT, SPARKS OR OPEN FLAME.
STORE IN COOL, WELL VENTILATED AREA.May be absorbed through the skin. Harmful or fatal if swallowed.
Use with adequate ventilation. Avoid prolonged breathing of vapors.Avoid contact with eyes or skin. Keep container tightly capped when not in use.
KEEP OUT OF REACH OF CHILDREN - FIRST AID:EYES: Flush thoroughly with water for at least 15 minutes. Call physician immediately.
INTERNAL: Do not induce vomiting. Call physician immediately.EXTERNAL: Wash thoroughly with soap and water and
apply a skin lotion. Wash clothing before re-use.
Max VOC per SCAQMD 1168/316A: 510G/LLow VOC products may be suitable or required for use on projects
following green building codes or rating systems.
READ THE FOLLOWING BEFORE USING: Contains Tetrahydrofuran, CAS# 109-99-9; Methyl Ethyl Ketone,CAS# 78-93-3; Cyclohexanone, CAS# 108-94-1 and Acetone, CAS# 67-64-1.
WARNING: EXTREMELY FLAMMABLE.HARMFUL OR FATAL IF SWALLOWED.ANTIDOTE: IN CASE OF INGESTION,
DO NOT INDUCE VOMITING.CALL A PHYSICIAN IMMEDIATELY.
STOCK CODE# G32NET CONTENTS QUART - 32 FL. OZ. (947 ml)
Scan for MSDS Sheet
R
PW, DWV, SWLowVOC
CM
T1Q
CU
TC
LEA
NP
RIM
EC
EM
EN
TA
SS
EM
BLE
MEDIUM BODY - GRAY
PVC CEMENT
DIRECTIONS1. Stir or shake before using.2. Cut pipe square with hand saw or pipe cutter and remove burrs from inside andoutside diameters.3. Clean pipe and fitting socket with Centaur’s Pipe Cleaner. Wipe off with a cleandry cloth.4. Check dry fit. Pipe should easily go 1/3 of the way into fitting. Use Centaur’s Primer. Primer will penetrate quickly for better bond.5. Apply a thin coat of cement into socket and a full even coat to pipe. WARNING: Use appropriate size dauber or larger applicator if necessary. Do not puddle cement in socket fitting.6. Engage pipe into filling with slight twisting motion. Be surepipe is bottomed into fitting. Hold pipe ad fitting for 30 seconds. Wipe off excess cement.7. Allow cement to cure before pressurizing pipe.8. As Stated in ASTM D2855, when installing thin walled bell end pipe, do notapply an excess of cement in the bell socket.
LIMITED WARRANTY: Manufacturer’s only obligation shall be to replace such quantities of the product proven to be defective. Return to manufacturer for free replacement.
APPLICATION TEMP: -17°F TO 120°F (-28°C TO 48°C).STORAGE TEMP: 40°F TO 100°F (5°C TO 38°C).
10. Follow all recommended procedures for joining PVC pipe and fittingsas stated in ASTM SPEC. D 2855.
• Fast• App Temp: -17°F to 120°F• High Strength for PVC Pipe & Fittings• Schedule 40 & 80 up to6” Dia. Pressure.8” Dia. Non Pressure• For Potable Water, DWV, & Sewer Applications.• Meets ASTM D-2564
This cement is made with the highest quality materials and meets or exceeds ASTMSPEC. D 2564. All information provided is based on our laboratory testing, independent laboratory test results, and actual field experience. Properly used, this material will performin accordance with applicable standards. Since we are unable to control conditions for whichthe product is being used, our only obligation will be the replacement of the cement.
CENTAUR MANUFACTURING635 NW Enterprise Dr. Port St Lucie, FL 34986
ph. 772-344-9436 • www.centaurpvc.com
WARNING: EXTREMELY FLAMMABLEDO NOT USE NEAR HEAT, SPARKS OR OPEN FLAME.
STORE IN COOL, WELL VENTILATED AREA.May be absorbed through the skin. Harmful or fatal if swallowed.
Use with adequate ventilation. Avoid prolonged breathing of vapors.Avoid contact with eyes or skin. Keep container tightly capped when not in use.
KEEP OUT OF REACH OF CHILDREN - FIRST AID:EYES: Flush thoroughly with water for at least 15 minutes. Call physician immediately.
INTERNAL: Do not induce vomiting. Call physician immediately.EXTERNAL: Wash thoroughly with soap and water and
apply a skin lotion. Wash clothing before re-use.
Max VOC per SCAQMD 1168/316A: 510G/LLow VOC products may be suitable or required for use on projects
following green building codes or rating systems.
READ THE FOLLOWING BEFORE USING: Contains Tetrahydrofuran, CAS# 109-99-9; Methyl Ethyl Ketone,CAS# 78-93-3; Cyclohexanone, CAS# 108-94-1 and Acetone, CAS# 67-64-1.
WARNING: EXTREMELY FLAMMABLE.HARMFUL OR FATAL IF SWALLOWED.ANTIDOTE: IN CASE OF INGESTION,
DO NOT INDUCE VOMITING.CALL A PHYSICIAN IMMEDIATELY.
STOCK CODE# CMT1QNET CONTENTS QUART - 32 FL. OZ. (947 ml)
Scan for MSDS Sheet
R
PW, DWV, SWLowVOC
CM
T1Q
CU
TC
LEA
NP
RIM
EC
EM
EN
TA
SS
EM
BLE
AT32 CENTAUR ALL TEMP. CEMENT
PVC CEMENT
Tetrahydrofuran Helps breakdown the PVC molecules.
Methyl Ethyl KetoneWorks together with Tetrahydrofuran to break down the PVC molecules and protect the seal.
CyclohexanoneUsed as a filler to close gaps.
AcetoneCleans the surface of the pipe to ensure a good seal.