9
Improving transient photoconductance lifetime measurements on ingots with deeper photogeneration Mohsen Goodarzi, Ronald A. Sinton, and Daniel Macdonald Citation: AIP Conference Proceedings 1999, 020008 (2018); doi: 10.1063/1.5049247 View online: https://doi.org/10.1063/1.5049247 View Table of Contents: http://aip.scitation.org/toc/apc/1999/1 Published by the American Institute of Physics Articles you may be interested in Temperature dependent imaging of solar cell losses AIP Conference Proceedings 1999, 020005 (2018); 10.1063/1.5049244 Collection efficiency at near-bandgap wavelengths in actual Si solar cells AIP Conference Proceedings 1999, 020001 (2018); 10.1063/1.5049240 Simple modeling of intrinsic bulk lifetime in doped silicon AIP Conference Proceedings 1999, 020003 (2018); 10.1063/1.5049242 Defects detection in p-n junction isolation by electroluminescence AIP Conference Proceedings 1999, 020006 (2018); 10.1063/1.5049245 Suns-ILIT: Accurate method for non-contacted local IV measurements AIP Conference Proceedings 1999, 020015 (2018); 10.1063/1.5049254 Saturation current as a function of sheet resistance in Si AIP Conference Proceedings 1999, 020002 (2018); 10.1063/1.5049241

Improving transient photoconductance lifetime measurements ...eng.anu.edu.au/sites/default/files/topic/mg.pdf · of 1.27×10 21 cm-2 s-1, equivalent to 5500 suns intensity, which

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Improving transient photoconductance lifetime measurements ...eng.anu.edu.au/sites/default/files/topic/mg.pdf · of 1.27×10 21 cm-2 s-1, equivalent to 5500 suns intensity, which

Improving transient photoconductance lifetime measurements on ingots with deeperphotogenerationMohsen Goodarzi, Ronald A. Sinton, and Daniel Macdonald

Citation: AIP Conference Proceedings 1999, 020008 (2018); doi: 10.1063/1.5049247View online: https://doi.org/10.1063/1.5049247View Table of Contents: http://aip.scitation.org/toc/apc/1999/1Published by the American Institute of Physics

Articles you may be interested inTemperature dependent imaging of solar cell lossesAIP Conference Proceedings 1999, 020005 (2018); 10.1063/1.5049244

Collection efficiency at near-bandgap wavelengths in actual Si solar cellsAIP Conference Proceedings 1999, 020001 (2018); 10.1063/1.5049240

Simple modeling of intrinsic bulk lifetime in doped siliconAIP Conference Proceedings 1999, 020003 (2018); 10.1063/1.5049242

Defects detection in p-n junction isolation by electroluminescenceAIP Conference Proceedings 1999, 020006 (2018); 10.1063/1.5049245

Suns-ILIT: Accurate method for non-contacted local IV measurementsAIP Conference Proceedings 1999, 020015 (2018); 10.1063/1.5049254

Saturation current as a function of sheet resistance in SiAIP Conference Proceedings 1999, 020002 (2018); 10.1063/1.5049241

Page 2: Improving transient photoconductance lifetime measurements ...eng.anu.edu.au/sites/default/files/topic/mg.pdf · of 1.27×10 21 cm-2 s-1, equivalent to 5500 suns intensity, which

Improving Transient Photoconductance Lifetime Measurements on Ingots with Deeper Photogeneration

Mohsen Goodarzi1, a), Ronald A Sinton2 and Daniel Macdonald1

1 Research School of Engineering, The Australian National University (ANU), Canberra ACT 2601, Australia. 2 Sinton Instruments Inc., Boulder CO USA. http://www.sintoninstruments.com.

a) Corresponding author: [email protected]

Abstract. Transient PhotoConductance Decay (PCD) measurements on silicon ingots and blocks with different photo-generation profiles are simulated in this work. The results show that a deeper generation profile, achieved by using long-pass optical filters with longer cut off wavelengths, can improve the accuracy of the transient lifetime measurements by approximately 10% in the lifetime range above 150 μs under typical measurement conditions. This improvement is due to reduced recombination at the unpassivated surface as the carrier density profiles peak is moved deeper into the bulk. The simulation results are confirmed by comparison with experimental lifetime measurements using three different optical filters on a monocrystalline silicon block.

INTRODUCTION

The carrier lifetime is one of the key parameters for the performance of silicon solar cells and is invaluable for process control. The transient PhotoConductance Decay (PCD) and Quasi-Steady State PhotoConductance (QSSPC) techniques are widely used for bulk lifetime measurements on silicon wafers and ingots [1]. The effective lifetime itself is a critical factor in the choice of which lifetime measurement technique to apply [2, 3]. Transient PhotoConductance decay is difficult to use, in practice, in samples with low carrier lifetimes as the illumination source decay time is typically not fast enough to measure lifetimes below 100 µs. On the other hand, the steady-state assumption is less valid in the higher range of lifetime when using typical flash decay times, and so transient decay lifetime measurements are preferable techniques for silicon blocks with high minority carrier lifetimes [4]. In addition, for measurements on ingots or blocks, transient measurements are less prone to the effect of the high Surface Recombination Velocity (SRV) associated with the unpassivated surface, provided that the initial surface-dominated component is allowed to decay [3, 5].

Schuler et al. [6] demonstrated the improved accuracy of lifetime measurements by using a deeper generation profile in MDP (Microwave Detected PhotoConductance) as a method with steady state photogeneration, in comparison with µPCD (microwave detected PhotoConductance Decay) as a method with transient photogeneration, on thick silicon samples. Several studies (for example Mitchell et al. in [7-9], and [4, 10, 11] ) have also demonstrated the accuracy of PhotoLuminescence (PL) techniques for lifetime measurements on silicon blocks, such as PL Intensity Ratio (PLIR) methods, in which the ratio of PL intensities at two different detection wavelength ranges is used to determine the lifetime. More recently, Chung et al. [12], have demonstrated a PLIR technique in which two different excitation wavelengths of 915 and 1064nm are used to generate different carrier profiles with deep generation.

In this work, transient PCD lifetime measurements in silicon blocks are modeled, with an emphasis on the impact of deeper photo-generation profiles. A modeling tool is used to simulate PCD measurements performed using a "BCT-400" measurement system from Sinton Instruments. The impact of shifting the generation profile peak deeper in the sample, by using longer cut-off wavelength long-pass filters in front of the flash, is explored. The simulation results are confirmed by measurement on a Cz p-type monocrystalline silicon block using a BCT-400 tool with three different optical filters.

SiliconPV 2018, The 8th International Conference on Crystalline Silicon PhotovoltaicsAIP Conf. Proc. 1999, 020008-1–020008-8; https://doi.org/10.1063/1.5049247

Published by AIP Publishing. 978-0-7354-1715-1/$30.00

020008-1

Page 3: Improving transient photoconductance lifetime measurements ...eng.anu.edu.au/sites/default/files/topic/mg.pdf · of 1.27×10 21 cm-2 s-1, equivalent to 5500 suns intensity, which

MODELING AND SIMULATION

For the transient mode simulations, the first stage is a QSS simulation, in order to build up the initial carrier concentration before the flash is terminated and the transient decay commences.

As explained in detail in [13, 14], the sample thickness was divided into intervals Δx small enough to ensure the electron current across the Δx thickness can be considered constant. Then, numerical analysis involves equating the total generation and total recombination rates of excess minority carriers across the sample thickness (W) as well as numerically solving the continuity equation in each element (Δx thick), including the diffusion of carriers into and out of the elements:

∆ ∆ ∆ (1)

where Jn is the electron current density (assuming p-type material) and G and U are the generation and the recombination rates respectively. Rearranging (1) results in [13]:

∆ ∆ ∆ ∆ ∆ (2)

In which Δn(x) is the excess carrier density at the depth of x, Deff is the effective diffusivity and Dn and Dp are electron and hole diffusivities. As there is no output current in ingot measurements, J = 0, the last element of (2) is eliminated in the calculations. For the boundary condition at the surface (at x = 0), we have:

0 ∆

∆ ∆ (3)

where Jn (0) and Δn (0) are the current density and the excess carrier density at the surface, respectively. NA is the sample doping and SRV is the surface recombination velocity which is assumed to be 106 cms-1 in all simulations presented in this paper.

The Δnavg(t) (weighted average minority carrier density, Δnavg and other parameters as explained in detail in [15] and [14]) at time t elapsed after terminating the light source, with the transient lifetime τtransient calculated from the slope of the average excess carrier density decay. This can be expressed with the continuity equation as [16]:

, , (4)

where G and U are the generation and the recombination rates respectively, and the last term is a diffusion term caused

by non-uniform carrier densities. Equation (4) is numerically solved for the QSS mode (when ∆

= 0) as explained

above and in detail in [14]. Then the light source is terminated at t = 0 and the transient mode (when G(t) = 0) is simulated after that. The simulations were based on a finite elements approach, with the depth and time intervals Δx and Δt chosen to be small enough to ensure the local changes in the excess carrier density are approximately linear in

x and t. The excess carrier density within a depth interval constantly changes over time (∆

0) as there is no

photogeneration. This means the excess carrier density within an element Δx varies not only due to recombination but also because of a diffusion current to and from the adjacent depth intervals.

Therefore, Δt must be chosen to be very small in comparison with the lifetime to ensure the change due to recombination is insignificant within the time interval (on the order of 10 ns) while the diffusion current element is calculated. In practice τtransient is limited by surface recombination and Shockley–Read–Hall (SRH) recombination centers in the bulk, in addition to intrinsic recombination due to Auger and radiative recombination [17]:

1 1 1 1 1

or (5)

020008-2

Page 4: Improving transient photoconductance lifetime measurements ...eng.anu.edu.au/sites/default/files/topic/mg.pdf · of 1.27×10 21 cm-2 s-1, equivalent to 5500 suns intensity, which

FIGURE 1. Xenon flash spectrum and measured filter transmission functions.

As a Sinton Instruments BCT-400 tool is used in this work, the assumptions for the light source and the filter transmission in the simulations are adapted from the tool setup. In this case we assume a pre-filter peak photon flux of 1.27×1021 cm-2s-1, equivalent to 5500 suns intensity, which is a typical peak intensity for the X5dR Q-flash from Quantum Instruments used in a Sinton Instruments BCT-400 tool. Inserting a standard 1000-nm IR-Pass Schott glass RG1000 filter in place, further reduces the on-sample photon flux to 2.3 ×1020 cm-2s-1. The xenon flash spectrum and the measured transmission function for the standard RG1000 filter are shown in yellow and black lines respectively in FIGURE 1.

Figure 2.a) shows the excess carrier density profiles as a function of depth at various elapsed times after turning the light source off. The results are for a case of p-type silicon with a bulk lifetime of 300 μs.

Note that the peak of the excess carrier density profiles moves deeper into the bulk as a function of time. Therefore, the effect of the high SRV of an as-cut unpassivated surface on the calculated lifetime is reduced and, consequently, τtransient will become closer to τbulk.

FIGURE 2. a) Excess carrier density profile as a function of sample depth at various elapsed times after turning the light source off. b) Simulated weighted injection level (Δnavg) decay as a function of elapsed time for different bulk lifetime values. The

dashed line intercepts with the curves indicate when the injection level has decayed to 1015 cm-3 where the slope is calculated to determine the transient lifetime. Simulations were performed assuming a standard RG1000 filter.

It should be noted here that all simulated lifetimes in this paper are calculated with the coil depth sensitivity function taken into the account for the excess carrier density that is sensed by the tool:

020008-3

Page 5: Improving transient photoconductance lifetime measurements ...eng.anu.edu.au/sites/default/files/topic/mg.pdf · of 1.27×10 21 cm-2 s-1, equivalent to 5500 suns intensity, which

∆ ∆.

(6)

which is described in detail in [14, 18]. This is to enable simulations under realistic measurement conditions, thereby allowing comparison with measured lifetimes.

Figure 1.b) illustrates the continuous decay of the weighted average minority carrier density, Δnavg, over time after the light source was terminated for different bulk lifetimes (τbulk). The simulated transient lifetime at any specific injection level is then determined by the slope of the minority carrier profiles [19]:

(7)

Simulations were also performed using optical filters with longer wavelengths to obtain deeper photogeneration.

Two high-performance OD 4 long-pass filters from Edmund Optics with a sharp cut-off wavelength at 1050 nm (EO-1050) and 1100 nm (EO-1100) respectively are used to generate such deep photogenerations. Figure 1 shows the measured transmission function for these two filters and the standard RG1000 filter, along with the xenon flash spectrum. The longer and very sharp cut-off wavelengths of the EO filters move the carrier density profile peak deeper in the bulk. Figure 3 presents the tool reference cell QE and the filtered spectra for the three filters which hit the sample surface. As can be seen, the total photon flux will be reduced as the filters cut-off wavelength increases. This means that, in practice, there is a trade-off between achieving a deeper generation profile and maintaining a sufficiently large generation rate, or excess carrier density.

Due to the lower QE (dashed line in Fig.3) of the reference cell at longer wavelengths, the detected light intensity displayed by the tool will be less than the real intensity of the light which hits the sample surface. Hence, the mismatch factors for the reference cell QE at each wavelength applied to simulate the actual photon flux that hits the sample.

Figure 4 shows the initial excess carrier densities (solid lines) and photogeneration (dashed lines) profiles in a p-type silicon block created by the RG1000, EO1050 and EO1100 filters generated with a light source with the peak equivalent of 5500 suns. These carrier profiles are the steady-state profiles generated during the initial flash, before the flash is terminated and the transient decay is commenced. The carrier density profiles peak for each filter are displayed by an arrow. It can be clearly seen that the profile peak moves deeper inside the bulk by increasing the filter cut-off wavelength [6].

Figure 5 shows the subsequent simulated transient lifetimes calculated as a function of injection level after the flash is terminated. This simulates a typical transient PCD measurement. The reported transient lifetime is shown for τbulk = 150, 300 and 500 μs for comparison.

FIGURE 3. Filtered light spectrum with 3 filters and reference cell QE as functions of wavelength. The total light intensity is reduced as the cut-off wavelength increases.

020008-4

Page 6: Improving transient photoconductance lifetime measurements ...eng.anu.edu.au/sites/default/files/topic/mg.pdf · of 1.27×10 21 cm-2 s-1, equivalent to 5500 suns intensity, which

FIGURE 4. Generation (dashed lines) and excess carrier density (solid lines) profiles at t = 0 under steady-state conditions when the pre-filtered photon flux = 1.27 × 1021 cm-2s-1 (generating different initial injection levels as labeled) as functions of

sample depth for the three different filters. The improvement in the accuracy of the reported transient lifetime is approximately 10% when the longer cut-off

wavelength filters are used. The excess carrier density profiles during the transient decay for the three filters are shown in Fig. 6 when Δnavg

decayed from their initial values in Fig.3 to 1015 cm-3 for a bulk lifetime of 300 microseconds. As can be observed, the carrier profiles from the three filters are still noticeably different, including the profile

peak position, leading to the more accurate reported lifetimes for the longer cut-off filters, despite the significant time elapsed after flash termination.

FIGURE 5. Simulated transient lifetime as functions of injection levels for three different filters for bulk lifetime of

150, 300 and 500 μs.

EXPERIMENTAL RESULTS AND DISCUSSION

Three sets of transient measurements on a Cz block were performed with a BCT- 400 measurement system from Sinton Instruments in transient mode with a RG1000 filter and the EO 1050 and EO 1100 filters respectively. The sample was a rectangular block cut from a standard industrial Cz p-type monocrystalline silicon ingot, with a square base of 156×156 mm and a height of 320 mm. Initially, transient lifetime measurements were performed at one fixed point on the block with different filters to compare the lifetime as a function of injection level for the three filters.

020008-5

Page 7: Improving transient photoconductance lifetime measurements ...eng.anu.edu.au/sites/default/files/topic/mg.pdf · of 1.27×10 21 cm-2 s-1, equivalent to 5500 suns intensity, which

FIGURE 6. Excess carrier density profiles during the transient decay for 3 filters at Δnavg = 1015 cm-3. The measurement results are shown in Fig. 7 revealing that the filters which create deeper generation profiles result

in higher τtransient values at any specific Δnavg. The next step was to measure τtransient along the sample with the different filters and compare the values. This is

shown in Fig. 8 for 24 points on one side of the block, starting at 10 mm from the bottom up to 10 mm from the top with a 13 mm (the sensor width) gap between each point.

FIGURE 7. Measured transient lifetime as a function of injection level for three filters. Longer cut-off wavelengths result in higher lifetime at the a given injection level.

The measurement results show around 7% and 9% higher reported lifetimes at Δnavg = 1015 cm-3 along the block when the EO-1050 and EO-1100 filters are used respectively, compared to the RG1000 filter.

This shows that the number of photons with long wavelengths in the photon flux is more important than the flux intensity. As shown in Fig. 3), although the RG1000 passes a much higher light intensity, the attenuation of the photons with wavelengths longer than 1100 nm causes a shallower generation peak close to the surface and subsequently lower reported lifetime.

020008-6

Page 8: Improving transient photoconductance lifetime measurements ...eng.anu.edu.au/sites/default/files/topic/mg.pdf · of 1.27×10 21 cm-2 s-1, equivalent to 5500 suns intensity, which

FIGURE 8. Measured transient lifetime along the block for different filters.

CONCLUSIONS

Transient PhotoConductance decay lifetime measurements on silicon ingots are simulated in this paper. The accuracy of the results depends on the time elapsed after the light source is terminated due to the reducing impact of the high SRV as the carrier density profile peak moves deeper into the bulk. Different optical filters are used to create deeper photogeneration, resulting in increased measurement accuracy of around 10% in the lifetime range from 150-500 μs, as confirmed with measurements on a p-type Cz monocrystalline silicon block.

ACKNOWLEDGEMENTS

This project has been supported by the Australian Renewable Energy Agency (ARENA) through project RND009.

REFERENCES

1. Mohsen Goodarzi, et al. A comparison between quasi-steady state and transient photoconductance lifetimes in silicon ingots: simulations and measurements. in Photovoltaic Specialists Conference (PVSC), 2017, 43 th IEEE. 2017.

2. Schmidt, J. and A.G. Aberle, Accurate method for the determination of bulk minority-carrier lifetimes of mono-and multicrystalline silicon wafers. Journal of Applied Physics, 1997. 81(9): p. 6186-6199.

3. Sinton, R.A. and T. Trupke, Limitations on dynamic excess carrier lifetime calibration methods. Progress in Photovoltaics: Research and Applications, 2012. 20(2): p. 246-249.

4. Giesecke, J.A., et al., Determination of Bulk Lifetime and Surface Recombination Velocity of Silicon Ingots From Dynamic Photoluminescence. IEEE Journal of Photovoltaics, 2013. 3(4): p. 1311-1318.

5. Giesecke, J.A., et al., Harmonically Modulated Luminescence: Bridging Gaps in Carrier Lifetime Metrology Across the PV Processing Chain. IEEE Journal of Photovoltaics, 2015. 5(1): p. 313-319.

6. Schüler, N., et al., Theoretical and experimental comparison of contactless lifetime measurement methods for thick silicon samples. Solar Energy Materials and Solar Cells, 2010. 94(6): p. 1076-1080.

7. Mitchell, B., et al., Bulk minority carrier lifetimes and doping of silicon bricks from photoluminescence intensity ratios. Journal of Applied Physics, 2011. 109(8): p. 083111.

8. Mitchell, B., et al., On the method of photoluminescence spectral intensity ratio imaging of silicon bricks: Advances and limitations. Journal of Applied Physics, 2012. 112(6): p. 063116.

9. Mitchell, B., et al., Imaging As-Grown Interstitial Iron Concentration on Boron-Doped Silicon Bricks via Spectral Photoluminescence. IEEE Journal of Photovoltaics, 2014. 4(5): p. 1185-1196.

020008-7

Page 9: Improving transient photoconductance lifetime measurements ...eng.anu.edu.au/sites/default/files/topic/mg.pdf · of 1.27×10 21 cm-2 s-1, equivalent to 5500 suns intensity, which

10. Chung, D., et al., Bulk Lifetimes up to 20 ms Measured on Unpassivated Silicon Discs Using Photoluminescence Imaging. IEEE Journal of Photovoltaics, 2017. 7(2): p. 444-449.

11. Giesecke, J.A., et al., Minority carrier lifetime in silicon wafers from quasi-steady-state photoluminescence. Applied Physics Letters, 2010. 97(9): p. 092109.

12. Chung, D., et al., Lifetime Imaging on Silicon Bricks Using the Ratio of Photoluminescence Images With Different Excitation Wavelengths. IEEE Journal of Photovoltaics, 2018: p. 1-9.

13. Cuevas, A., Modelling silicon characterisation. Energy Procedia, 2011. 8: p. 94-99. 14. Goodarzi, M., et al., Accuracy of Interstitial Iron Measurements on P-Type Multicrystalline Silicon Blocks by Quasi-Steady-

State Photoconductance. IEEE Journal of Photovoltaics, 2017. 7(5): p. 1216-1223. 15. Bowden, S. and R.A. Sinton, Determining lifetime in silicon blocks and wafers with accurate expressions for carrier density.

Journal of Applied Physics, 2007. 102(12): p. 124501. 16. Nagel, H., C. Berge, and A.G. Aberle, Generalized analysis of quasi-steady-state and quasi-transient measurements of carrier

lifetimes in semiconductors. Journal of Applied Physics, 1999. 86(11): p. 6218. 17. Kerr, M.J. and A. Cuevas, General parameterization of Auger recombination in crystalline silicon. Journal of Applied Physics,

2002. 91(4): p. 2473-2480. 18. Swirhun, J.S., et al., Contactless measurement of minority carrier lifetime in silicon ingots and bricks. Progress in Photovoltaics:

Research and Applications, 2011. 19(3): p. 313-319. 19. Cuevas, A. and D. Macdonald, Measuring and interpreting the lifetime of silicon wafers. Solar Energy, 2004. 76(1-3): p. 255-

262.

020008-8