2
1230978-2A-B 1 BEFORE YOU BEGIN All information is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. Please leave these instructions for the consumer. They contain important information. NOTES: 1. Flush the water supply pipes thoroughly to remove debris. 2. For new installations, assemble the faucet to sink before installing. 3. The highest working pressure for handspray & shower head is 0.5MPa(5bar). If it exceeds 0.5MPa(5bar), a pressure reducer is needed. The highest water and environment temperature is 60ºC. Please keep handspray, shower head and the shower arm away from heater, or it may become damaged and cause injury to the user. HANDLE OPERATION Lift the handle gently. Turn clockwise for hot water, turn counter-clockwise for cold water. INSTALLATION INSTRUCTIONS 10415T-B Single Lever Kitchen Faucet 10416T-B Single Lever Kitchen Faucet With Handspray FORTE ROUGH-IN DIMENSIONS 230 230 30Max G1/2˝ 400 155 18° 230 230 30Max 400 155 18° G1/2˝ Ø32~Ø37 125 115 30Max 22 35 Ø32~Ø37

INSTALLATION INSTRUCTIONS FORTEresources.kohler.com/plumbing/kohlerapac/pdf/1230978-2A... · 2017. 12. 21. · 2. For new installations, assemble the faucet to sink before installing

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INSTALLATION INSTRUCTIONS FORTEresources.kohler.com/plumbing/kohlerapac/pdf/1230978-2A... · 2017. 12. 21. · 2. For new installations, assemble the faucet to sink before installing

1230978-2A-B 1

BEFORE YOU BEGIN

All information is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice.

Please leave these instructions for the consumer. They contain important information.

NOTES:

1. Flush the water supply pipes thoroughly to remove debris.

2. For new installations, assemble the faucet to sink before installing.

3. The highest working pressure for handspray & shower head is 0.5MPa(5bar). If it exceeds 0.5MPa(5bar), a pressure reducer is needed. The highest water and environment temperature is 60ºC. Please keep handspray, shower head and the shower arm away from heater, or it may become damaged and cause injury to the user.

HANDLE OPERATION

Lift the handle gently. Turn clockwise for hot water, turn counter-clockwise for cold water.

INSTALLATION INSTRUCTIONS10415T-B Single Lever Kitchen Faucet

10416T-B Single Lever Kitchen Faucet With Handspray

FORTE

ROUGH-IN DIMENSIONS

230

230

30M

ax

G1/2˝

400

155

18°

230

230

30M

ax

400

155

18°

G1/2˝

Ø32~Ø37

125

115

30M

ax

22

35

Ø32~Ø37

Page 2: INSTALLATION INSTRUCTIONS FORTEresources.kohler.com/plumbing/kohlerapac/pdf/1230978-2A... · 2017. 12. 21. · 2. For new installations, assemble the faucet to sink before installing

1230978-2A-B 2

1230978-2A-B 3

INSTALLATION

INSTALLATION CHECKOUT

CLEANING INSTALLATIONS

How To Install The Faucet

Only for 10415T-B & 10416T-B

Put the washer(3) into the groove(1) of the body assembly. Screw the mounting stud(2) into the hole(A) of the faucet.

Place washer(4), bracket(5) and nut(6) onto the mounting stud(2) from the underside of the sink. Position the faucet so that mounting stud is toward the front. Tighten the nut to secure the faucet to the sink.

Attach the hoses to water supplies. When facing the back of the faucet, the left hose is hot water, the right hose is cold water.

How To Install The Handspray

Only for 10416T-B

Apply plumbers putty or other sealant to the undersider of the handspray holder(9) according to the putty manufacture's instructions.

Insert the handspray holder through the sink hole . From under the sink, securely hand-tighten the nut(10). Insert the handspray hose(8) through the handspray holder(7) and attach the hose to the handspray tube(11).

Ensure that all coupling nuts are tight. Ensure that the lever handle is in the off position. Turn on the main water supply and drain, and check for leaks. Repair as needed.

Remove the aerator(12). Run hot and cold water through the faucet for about one minute to remove any debris.

Flush the aerator. Shut off the faucet. Reinstall the aerator.

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc, which could adversely affect the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings.

**Color code must be specified when ordering

FORTESERVICE PARTS

71117

10416T-B:75878

711171005201

1148063**

76713

1003813

837166

1003662**

1018336**

1018337**

76248**

76245

1105656

1105656

1031237**

834754 10416T-B:1037431**

10416T-B:1229481

10416T-B:1021724**

836664

7

89

10

11

4

1

2

A

For 10415T-B

For 10416T-B

3

5

6

10415T-B

10416T-B

12

12

10415T-B Single Lever Kitchen Faucet 10416T-B Single Lever Kitchen Faucet With Handspray

"LEAD FREE" is marked on the back of the faucet signifying its compliance with the United States AB1953