Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
FENCE
KEY AND SELECT TRANSDUCER MONITORING WELLS FOR HIGH-GRADE WELL PROD_19
CHEVRON CINCINNATI FACILITYHOOVEN, OHIO
Checked By: Scale: Date:Drawn By: File:
www.trihydro.com
1252 Commerce DriveLaramie, Wyoming 82070
FIGURE 4-1
500KEY&SCTTRNWELLLOC8/21/071" = 650'DRREP
PROPERTY BOUNDARY
PRODUCTION WELL AND DESIGNATION
MONITORING WELL AND DESIGNATION
0 650'
STREAM
BUILDING, TANK OR OTHER STRUCTURE
KEY TRANSDUCER FLUID MONITORING WELL AND DESIGNATION
PROPOSED MONITORING WELL AND DESIGNATION
VAPOR MONITORING WELL AND DESIGNATION
SELECT TRANSDUCER FLUID MONITORING WELL AND DESIGNATION
THIS FIGURE ILLUSTRATES THE 2006 HIGH-GRADE SCENARIO IN WHICH PRODUCTION WELL PROD_19 WAS OPERATED AS THE HIGH-GRADE WELL. MONITORED WELLS WILL BE TAILORED IN ACCORDANCE WITH THE OMM PLAN TO CORRESPOND TO THE SELECTED HIGH-GRADE PRODUCTION WELL.
SELECT TRANSDUCER FLUID STREAM GAUGING STATION AND DESIGNATION
FENCE
KEY AND SELECT MANUAL FLUID MONITORING WELLS FOR
HIGH-GRADE WELL PROD_19
CHEVRON CINCINNATI FACILITYHOOVEN, OHIO
Checked By: Scale: Date:Drawn By: File:
www.trihydro.com
1252 Commerce DriveLaramie, Wyoming 82070
FIGURE 4-2
500KEY&SCT_WELLLOC12/3/071" = 650'DRREP
PROPERTY BOUNDARY
PRODUCTION WELL AND DESIGNATION
MONITORING WELL AND DESIGNATION
0 650'
STREAM
BUILDING, TANK OR OTHER STRUCTURE
VAPOR MONITORING WELL AND DESIGNATION
KEY MANUAL FLUID MONITORING WELL AND DESIGNATION
SELECT MANUAL FLUID MONITORING WELL AND DESIGNATION
THIS FIGURE ILLUSTRATES THE 2006 HIGH-GRADE SCENARIO IN WHICH PRODUCTION WELL PROD_19 WAS OPERATED AS THE HIGH-GRADE WELL. MONITORED WELLS WILL BE TAILORED IN ACCORDANCE WITH THE OMM PLAN TO CORRESPOND TO THE SELECTED HIGH-GRADE PRODUCTION WELL.
SELECT MANUAL FLUID RIVER GAUGING STATION AND DESIGNATION
PROPOSED MONITORING WELL AND DESIGNATION
Date:
Sampler:
HIGH-GRADE KEY WELLS
WELL TIME LAST WATER DEPTH WATER DEPTH LAST LNAPL
DEPTH LNAPL DEPTH
(ft) (ft) (ft) (ft)
Production Well*
MS-85S
MW-20S
MW-99S
MW-96S
MW-112
ADDITIONAL MONITORING FOR PRODUCTION WELL*
INSTANT. FLOW CUMULATIVE FLOW INSTANT. FLOW CUMULATIVE
FLOW(gpm) (gal) (gpm) (gal)
* Production well will vary depending on seasonal high-grade strategy.
FIGURE 4-3Key Well Fluid Level Log
FLUID LEVEL DATA - LNAPL THICKNESS AND GW ELEVATION
GROUNDWATER LNAPL
Date:
Sampler:
WELL TIME LAST WATER DEPTH WATER DEPTH LAST LNAPL
DEPTH LNAPL DEPTH
(ft) (ft) (ft) (ft)
Production Well*
MW-17
MW-44
RBGP-44
MW-88
MW-85S
MW-10
MW-4
MW-1D
MW-1R
MW-112
MW-20D
MW-20S
Production Well*
L-7
MW-62
MW-81S
MW-92S
MW-128
MW-93S
MW-101S
MW-94S
MW-114S
MW-37
MW-129
MW-100S
MW-99S
MW-96S
ADDITIONAL MONITORING FOR PRODUCTION WELL*
INSTANT. FLOW CUMULATIVE FLOW INSTANT. FLOW CUMULATIVE
FLOW(gpm) (gal) (gpm) (gal)
* Production well will vary depending on seasonal high-grade strategy. Key wells are noted in italics.
LNAPLGROUNDWATER
FLUID LEVEL DATA - LNAPL THICKNESS AND GW ELEVATION
FIGURE 4-4Select and Key Well Fluid Level Log
FENCE
GAC LAYOUT PLAN
CHEVRON CINCINNATI FACILITYHOOVEN, OHIO
Checked By: Scale: Date:Drawn By: File:
www.trihydro.com
1252 Commerce DriveLaramie, Wyoming 82070
FIGURE 5-1
500GACLAYOUT12/3/071" = 600'DRREP
PROPERTY BOUNDARY
PRODUCTION WELL AND DESIGNATION
0 600'
STREAM
BUILDING, TANK OR OTHER STRUCTURE
SOLID WASTE MANAGEMENT UNIT (SWMU)
GROUNDWATER SYSTEM
GRANULAR ACTIVATED CARBONGAC
HSVE LAYOUT PLAN
CHEVRON CINCINATI FACILITYHOOVEN, OHIO
Checked By: Scale: Date:Drawn By: File:
www.trihydro.com
1252 Commerce DriveLaramie, Wyoming 82070
FIGURE 6-1
500HSVE_MAP1/15/071" = 200'DRVLP
EXPLANATION
0 200'
HSVE PROJECTED RADIUS OF CAPTURE
HSVE LINES, DASHED WHERE SCREENED
VAPOR MONITORING WELL AND DESIGNATION
Date:
Sampler:
HSVE LINE TIME INSERTIONDEPTH
PITOT TUBE READING VACUUM FLOW CH4 CO2 O2 LEL
TOTAL ORGANIC
VAPOR(in) (in-H2O) (in-Hg) (scfm) (%) (%) (%) (%) (ppm)
1 (Central) 4.2 TBD
2 (Southern) 1.2 TBD
3 (Northern) 2.2 TBD
Combined NA NA NA
Notes:Combined flow rate as indicated on HSVE instrumentation panel; other flow rates calculated based on pitot tube and line pressure readings.
COMMENTS:
HSVE FIELD SCREENING LOG
FIGURE 6-2
Date:
Sampler:
HSVE LINE TIME INSERTIONDEPTH
PITOT TUBE READING VACUUM FLOW CH4 CO2 O2 LEL
TOTALORGANIC
VAPORSAMPLE ID CANISTER
NUMBERSTART
VACUUMFINAL
VACUUM
(in) (in-H2O) (in-Hg) (scfm) (%) (%) (%) (%) (ppm) (in-Hg) (in-Hg)
1 (Central) 4.2 TBD
2 (Southern) 1.2 TBD
3 (Northern) 2.2 TBD
ThermOx Influent NA NA NA
ThermOxEffluent NA NA NA
Notes:Combined flow rate as indicated on HSVE instrumentation panel; other flow rates calculated based on pitot tube and line pressure readings.
COMMENTS:
DATE SAMPLES SHIPPED TO LAB:
FIGURE 6-3
HSVE SAMPLE COLLECTION LOG
COC NUMBER:
FENCE
NESTED VAPOR MONITORING WELLS
CHEVRON CINCINNATI FACILITYHOOVEN, OHIO
Checked By: Scale: Date:Drawn By: File:
www.trihydro.com
1252 Commerce DriveLaramie, Wyoming 82070
FIGURE 7-1
500NESTVAPOR_WELLLOC8/21/071" = 650'DRREP
PROPERTY BOUNDARY
PRODUCTION WELL AND DESIGNATION
MONITORING WELL AND DESIGNATION
0 650'
STREAM
BUILDING, TANK OR OTHER STRUCTURE
NESTED VAPOR MONITORING WELL AND DESIGNATION
PROPOSED MONITORING WELL AND DESIGNATION
GULF PARK SITE MAP
GULF COMMUNITY PARKCLEVES, OHIO
Checked By: Scale: Date:Drawn By: File:
www.trihydro.com
1252 Commerce DriveLaramie, Wyoming 82070
FIGURE 8-1
500GP_SITEMAP_OMM8/22/071"=200'DRREP
EXPLANATION
0 200'
BUILDING OR STRUCTURE
EASEMENT/RIGHT-OF-WAY
ROADGENERAL TOPOGRAPHIC CONTOUR (FT-AMSL, INTERVAL: 2', DASHED WHERE INFERRED)
EXPANDED BIOVENTING SYSTEM PIPE RUN #3
EXPANDED BIOVENTING SYSTEM PIPE RUN #2
EXPANDED BIOVENTING SYSTEM PIPE RUN #1
SHALLOW GROUNDWATER MONITORING WELL AND DESIGNATION
EXPANSION BIOVENT WELL AND DESIGNATION
SOIL GAS MONITORING POINT AND DESIGNATION
EXPANSION SOIL GAS MONITORING POINT AND DESIGNATION
ANNUAL GULF PARK SAMPLING WELL AND DESIGNATION
BIOVENT WELL AND DESIGNATION
FEET ABOVE MEAN SEA LEVELFT-AMSL