1
GLD46A180 GLD46A180 GLD46A180 GLD46A180 GLD46A180 GLD56A225 GLD56A225 GLD56A225 GLD56A225 GLD56A225 GHD36180 GLD56A225 KRD44P148 KRD44P148 KRD34P111 KRD64P220 KRD54P185 KRD54P185 KRD54P185 KRD54P185 GLD46A180 GLD56A225 GLD66A268 GLD36A135 GLD26A090 GLD26A090 GLD26A090 GLD46D180 GLD46D180 GLD46A180 GLD56A225 GLD66A268 GLD56A225 GLD56A225 GLD56A225 GLD56A225 GLD56A225 KRD34P111 GLD26A090 GHD36180 EX.FCO EX.FCO EX. 4" S9.19 EX. 4" S9.19 EX. 4" S2.19 EX. 3" S2.19 EX. 3" S9.19 EX. 3" S9.19 EX. 3" S9.19 EX. 1 1/2" V1.19 EX. 4" S2.19 EX. 6" S1.19 EX. 4" S2.19 EX. 4" S2.19 EX. 6" S1.19 CAP EX. HD EX. 3" S1.19 P1.1 2 EX.S8.3 EX. 3/4" S8.3 EX. 3/4" S8.3 S8.3 S8.3 EX. FCO EX. FD EX. 4" S9.19 EX.FCO DATA ROOM 107 DELI COOLER 310 DELI SERVICE #1 311 MEAT PREP 316 GROCERY 201 CASH CONTROL 111 BREAK ROOM 112 ENTRANCE VESTIBULE 100 RECEIVING ROOM 319 REFRIG. PIT 501 DEPT. MGR. OFFICE 119 QUICK PICK RM. 106 BAKERY FREEZER 301 BAKERY COOLER 300 BAKERY PREP 302 PRODUCE PREP 304 SOUTH STOCK 307 PRODUCE COOLER 306 DELI FREEZER 308 MEAT COOLER 317 MEAT FREEZER 318 GROCERY FREEZER 322 DAIRY COOLER 326 CLEANING CENTER 324 EMPLOYEE RESTROOM 325 ELECTRICAL ROOM 321 WOMEN'S 118 MEN'S 117 MANAGERS OFFICE 115 PRICING ROOM 120 COURTESY 113 LOCKING LIQUOR STOR. 114 FS1 P - 2 EX. FCO EX. FCO FCO HD3 HD3 FCO 1'8" B.F.F. FCO FCO FCO EX. 4" S2.19 EX. 4" S1.19 EX. 4" S9.19 EX. 4" S9.19 3" S9.19 FCO FCO FCO FCO EX. FCO FCO 3'2" B.F.F. P - 1 P - 1 P - 1 P - 1 P - 3 P - 1 EX.FD P - 2 P - 4 P - 4 P - 4 P - 4 DF1 PROVIDE NEW UNDERSLAB CONNECTION TO GREASE WASTE MAIN AS SHOWN. HD3 HD3 EX. FCO HD3 P - 7 HD3 EX.SK FCO FCO S8.3 DRAIN TO BE RELOCATED PIPING TO BE FILLED, CAPPED AND ABANDONED HD3 FCO HD3 PIPING ROUTED BELOW BEAMS TO ACCOMMODATE VENT FD1 FIXTURES IN RESTROOM AREA (WATER CLOSETS, LAVATORIES, AND DRINKING FOUNTAIN) TO BE REPLACED WITH NEW SIMILAR FIXTURE IN SAME LOCATION. CONNECT NEW FIXTURE TO EXISTING UTILITIES. TYPICAL. EX. 4" S2.19 EX. 4" S2.19 EX. 6" S1.19 EX. 6" S1.19 EX. 4" S1.19 EX. 4" S2.19 EX. 6" S1.19 EX. 6" S1.19 EX. 4" S2.19 FCO FCO EX. 3" S1.19 FCO FCO HD3 FCO FCO CAP CAP REFRIG. PIT 500 P2 2" V1.19 3" S9.19 EX. FD EX.HD EX. FD EX.FCO 3" S2.19 CAP 3" PIPE PENETRATION AT 11" B.F.F. CAP CAP CAP CAP CAP FS1 P - 8 RELO.SK FS1 FCO 4" VTR 4" VTR HD3 HD3 FCO HD3 HD3 HD3 HD3 HD3 HD3 EX. 4" S9.19 EX. 4" S9.19 CAP CAP CAP P - 8 2" PIPE TO BE ROUTED BELOW GRADE BEAM. FCO P - 1 FD1 P - 5 FCO HD3 3" S9.19 3" S2.19 FCO FCO FD1 FD1 HD3 EX. HD HD4 HD4 HD3 FCO FCO HD3 3" S9.19 3" S9.19 3" S9.19 3" S 9. 19 FCO FCO 3" S9.19 GWI1 CAP FD1 FD1 FD1 EX. FCO HD3 HD3 P17 P28 P28 P28 P28 P28 TYP. P28 P35 P28 TYP. HD4 HD4 HD3 TD1 TD1 TD1 P30 P30 P30 P30 HD3 HD3 HD3 FD1 HD4 FD1 FD1 FD1 FD1 FS1 FS1 P - 11a P - 8 P28 TYP. TYP. P28 FD1 P28 TYP. P30 P35 HD4 P - 7 P35 TD1 TD1 TD1 P29 P29 P - 18 P34 4" VTR P29 4" VTR P35 P38 P32 EX. FD HD3 P - 7 P37 FS1 FD1 FD1 FD1 HD3 HD3 EX. HD P28 P28 P38 P28 EX. HD P28 P38 P38 P38 P28 EX. HD EX. HD P28 P33 P33 EX. HD EX. FCO TD1 P29 3/4" S8.3 3/4" S8.3 3/4" S8.3 P31 EX. FD EX. FD EX. FD EX. FD 3/4" S8.3 3/4" S8.3 TYP. P31 EX. HD EX. HD EX. HD P38 P38 P38 P28 P28 P28 P28 1 1/2" V1.19 3" S1.19 EX. FD 3/4" S 8.3 EX. HD EX. FD 4" S1.19 3" S2.19 P33 1 1/2" V1.19 P32 3/4" S8.3 P31 P32 CAP CAP P33 P33 P33 P33 CAP P32 CAP CAP CAP S8.3 CAP P33 P33 P33 P33 P33 P - 7 2" V1.19 3" S2.19 CAP EX. 3" S1.19 EX. 4" S2.19 EX. 6" S1.19 P33 P33 EX. 3" S2.19 4" S2.19 4" S1.19 HD4 P33 S8.3 S8.3 P31 2" V1.19 CAP P1.1 4 2" S2.19 CAP EX. FCO P1.1 3 P42 GCO P43 4" S1.19 P39 P47 P48 EX. HD NOTE: PIPING SERVING ALL HAND SINKS MOUNTED ON COOLER WALLS IS TO BE INSTALLED EXPOSED, FLUSH WITH WALL. P64 P64 P64 P64 P64 P64 P64 P64 P64 P64 P64 P64 P33 P33 P33 P65 P64 P65 P65 P65 P65 P65 FD1 P65 P65 P65 P64 P65 P65 P51 P51 P51 P51 P51 P65 P65 P64 P51 EX. FCO P65 P64 P65 P35 P64 CAP P30 HD3 P51 P29 P29 P29 P64 MEAT PREP 316 SEAFOOD FREEZER 314 REFRIG. PIT 502 SEAFOOD COOLER 313 SEAFOOD PREP 315 2" S2.19 1 1/2" V1.6 3" S2.19 3" S2.19 S8.3 S8.3 3/4" S8.3 1 1/2" V1.19 3/4" S8.3 FS1 HD3 FCO P - 8 EX. FS FCO S8.3 FD1 FS1 TD1 TD1 TD1 TD1 TD1 HD3 HD3 TD1 P30 P29 P29 3" VTR EX. 3" S9.19 EX. 3" S9.19 EX. HD S8.3 S8.3 3" S2.19 P38 EX. HD EX. HD P38 EX.FCO 3" S9.19 EX. 4" S9.19 EX. 4" S9.19 EX. 3" S9.19 3" S9.19 P33 P33 EX. HD S8.3 3" S2.19 3" S2.19 3" S2.19 3" S2.19 FCO P41 P29 P29 P32 P32 3" PIPE PENETRATION AT 12" B.F.F. REFER TO STRUCTURAL PLANS FOR DETAILS. EX. HD 2" V1.19 P31 P35 P28 FCO EX. 3/4" S8.3 P64 P64 3" S2.19 P65 P51 P29 1 1/2" V1.19 P64 MECHANICAL RM. 400 COMPRESSOR RM. 401 FD1 2" V1.19 3" VTR EX. 6" S1.19 EX. 6" S1.19 4" S1.19 S8.3 FLORAL COOLER 103 FLORAL PREP 102 UNISEX 105 GROCERY 201 ENTRANCE VESTIBULE 100 P - 2 FD4 P - 4 HD3 HD3 HD3 1 1/2" V1.19 4" VTR P35 P30 P33 P33 2" S1.19 3" S1.19 EX. 4" S2.19 HD3 HD3 3" S1.19 3" S1.19 EX. 6" S1.19 P52 P65 P33 P33 3/32" = 1'-0" 1 PLUMBING SANITARY & VENT PLAN - FLOOR - Overall OWNERSHIP OF INSTRUMENTS OF SERVICE All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by the Con sultant as instruments of service shall remain the property of the Consultant. The Consultant shall retain all common law, st atuto ry and other reserved rights, including, without limitation, the copyright thereto. SHEET NO. SHEET TITLE PROJECT NO: CAD DWG FILE: DRAWN BY: CHK'D BY: DESCRIPTION DATE MARK REVISIONS 2211 WINDMAN WAY SUITE 220 FORT MYERS, FL 33901 ARCHITECT CONSULTANT SEAL PROJECT INFO DATE 2" REFERENCE LINE WWW.KLHENGRS.COM MECHANICAL/ELECTRICAL ENGINEERS 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX LEXINGTON, KENTUCKY LOUISVILLE, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK KOHRS LONNEMANN HEIL ENGINEERS, INC. P1.1 PLUMBING SANITARY PLAN PJS MCD 3-12-2021 A REMODEL FOR STORE #38 CONSTRUCTION SET 2851 BELLE CHASSE HIGHWAY GRETNA, LA 21871 KEYED NOTES P2 CONNECT NEW VENT PIPING TO NEAREST EXISTING 2" MINIMUM VENT SYSTEM. P17 EXISTING CLEANOUT INVERT ELEVATION IS 33" B.F.F. P28 TIE THE CONDENSATE FROM THIS CASE INTO THE DRAIN OF A SIMILAR ADJACENT CASE ABOVE THE SLAB WITH AIR GAP. P29 P.C. MUST COORDINATE THE FINAL TRENCH DRAIN LOCATIONS WITH THE FINAL COOLER BOX PLACEMENT/INSTALLATIONS PRIOR TO FINAL CONCRETE POUR. THE TRENCH DRAINS MUST BE FINISHED SMOOTH, IMPERVIOUS, AND EASILY CLEANABLE. REFER TO DETAIL 221319.00-03 ON SHEET P6.1 FOR INSTALLATION. TYP. P30 REFRIGERATION/FREEZER/FAN COIL CONDENSATE DRAIN. PROVIDE AIR GAP. REFER TO DETAIL 221316.00-03 AND EVAPORATOR COIL DRAIN DETAIL ON SHEET P6.1 FOR DRAIN INSTALLATION. P31 PROVIDE HEAT TRACE FOR ALL CONDENSATE PIPING INSIDE OF COOLERS/FREEZERS. P32 ROUTE WASTE DISCHARGE FROM PREP SINK TO ADJACENT FLOOR SINK. REFER TO DETAIL ON SHEET P6.1 FOR INSTALLATION. P33 HUB DRAIN TO SERVE REFRIGERATED CASE. REFER TO DETAIL 221316.00-03 FOR DRAIN INSTALLATION. P34 REFER TO DETAIL 224000.00-02 ON SHEET P6.1 FOR MOP SINK INSTALLATION. P35 REFER TO DETAIL 221313.00-06 FOR VTR INSTALLATION. P37 EXISTING 3 COMPARTMENT SINK FROM PREVIOUS DELI PREP AREA IS TO BE RELOCATED TO THIS LOCATION. P38 REWORK EXISTING HUB DRAIN TO SERVE NEW REFRIGERATED CASE. COORDINATE WITH REFRIGERATION PRIOR TO BEGINNING WORK. P39 EXISTING 3 COMPARTMENT SINK FROM PREVIOUS PRODUCE PREP AREA IS TO BE RELOCATED TO THIS LOCATION. P41 DRAIN SERVING MEZZANINE AREA ABOVE FOR WATER HEATER RELIEF. P42 EXISTING FLOOR CLEANOUT TO REMAIN. VERIFY EXACT LOCATION AND RELOCATE IF CONFLICTING WITH NEW WALL. P43 REPLACE EXISTING GRADE CLEANOUT COVER WITH NEW CLEANOUT CAP. PATCH AND REPAIR EXISTING CONCRETE SLAB WITH NEW TO MATCH EXISTING. P47 EXISTING 3 COMPARTMENT SINK FROM PREVIOUS BAKERY PREP AREA IS TO BE RELOCATED TO THIS LOCATION. P48 EXISTING HAND SINK FROM PREVIOUS BAKERY PREP AREA IS TO BE RELOCATED TO THIS LOCATION. REFER TO HAND SINK DETAIL ON SHEET P6.1 FOR INSTALLATION. P51 REFER TO HAND SINK DETAIL ON SHEET P6.1 FOR INSTALLATION (TYPICAL). P52 WASTE PIPING BELOW CABINETRY IS TO EXTEND AWAY FROM WALL PRIOR TO PENETRATING SLAB IN ORDER TO AVOID GRADE BEAM. P64 PROVIDE NEW CLEANOUT. REFER TO DETAIL 221313.00-01 ON SHEET P5.1 FOR INSTALLATION. P65 REFER TO DETAIL 221316.00-01 FOR FLOOR DRAIN INSTALLATION. 1/4" = 1'-0" 2 MEAT PREP 3/32" = 1'-0" 3 PLUMBING WASTE AND VENT PLAN - MEZZANINE GENERAL NOTES PLUMBING CONTRACTOR TO FURNISH AND INSTALL PVC SLEEVES SERVING REFRIGERATION PIPING. REFER TO REFRIGERATION DRAWINGS FOR INSTALLATION. VERIFY INVERTS AND COORDINATE THE LOCATIONS OF ALL PENETRATIONS IN THE GRADE BEAMS WITH THE STRUCTURAL ENGINEER. 2 4-5-21 ADDENDUM #2 1/4" = 1'-0" 4 FLORAL AREA Plumbing Pipe Type Legend Mark Color System Name Pipe Material V1.19 S9.19 S2.19 S1.19 S8.3 V1.6 V7.6 V6.6 CD.6 V1 - Vent S9 - Indirect Waste S2 - Grease Waste S1 - Sanitary S8 - Condensate Drainage V1 - Vent V7 - Exhaust Air Flue Vent V6 - Intake Air Flue Vent - Condensate Drainage 19 - PVC - Schedule 40 - ASTM D1785/D2665 19 - PVC - Schedule 40 - ASTM D1785/D2665 19 - PVC - Schedule 40 - ASTM D1785/D2665 19 - PVC - Schedule 40 - ASTM D1785/D2665 3 - Copper - DWV - ASTM B306 6 - PVC - Schedule 40 - ASTM D1785 6 - PVC - Schedule 40 - ASTM D1785 6 - PVC - Schedule 40 - ASTM D1785 6 - PVC - Schedule 40 - ASTM D1785 2

KEYED NOTES - RPM & Associates

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KEYED NOTES - RPM & Associates

GLD46A180

GLD46A180

GLD46A180

GLD46A180

GLD46A180

GLD56A225

GLD56A225

GLD56A225

GLD56A225

GLD56A225

GHD36180

GLD56A225

KRD44P148

KRD44P148

KRD34P111

KRD64P220

KRD54P185 KRD54P185 KRD54P185 KRD54P185

GLD46A180

GLD56A225

GLD66A268

GLD36A135

GLD26A090

GLD26A090

GLD26A090

GLD46D180

GLD46D180

GLD46A180

GLD56A225

GLD66A268

GLD56A225

GLD56A225

GLD56A225

GLD56A225

GLD56A225

KRD34P111

GLD26A090

GHD3618

0

EX.FCOEX.FCO

EX. 4" S9.19EX. 4" S9.19

EX. 4" S2.19

EX. 3" S2.19

EX. 3" S9.19

EX. 3" S9.19

EX. 3" S9.19EX. 1 1/2" V1.19

EX. 4" S2.19

EX. 6" S1.19

EX. 4" S2.19

EX. 4" S2.19

EX. 6" S1.19

CAP

EX. HD

EX. 3" S1.19

P1.12

EX

.S8.3

EX. 3/4" S8.3

EX. 3/4" S8.3

S8.3

S8.3

EX. FCO

EX. FD

EX. 4" S9.19

EX.FCO

DATA ROOM

107

DELI

COOLER

310

DELI SERVICE #1

311

MEAT PREP

316

GROCERY

201

CASH

CONTROL

111

BREAK

ROOM

112

ENTRANCE VESTIBULE

100

RECEIVING ROOM

319

REFRIG. PIT

501

DEPT. MGR.

OFFICE

119QUICK PICK RM.

106

BAKERY

FREEZER

301

BAKERY

COOLER

300

BAKERY

PREP

302

PRODUCE PREP

304

SOUTH STOCK

307

PRODUCE COOLER

306

DELI

FREEZER

308

MEAT

COOLER

317

MEAT FREEZER

318

GROCERY FREEZER

322

DAIRY COOLER

326

CLEANING CENTER

324

EMPLOYEE RESTROOM

325

ELECTRICAL

ROOM

321

WOMEN'S

118

MEN'S

117

MANAGERS

OFFICE

115

PRICING

ROOM

120

COURTESY

113

LOCKING

LIQUOR

STOR.

114

FS1

P-2

EX. FCO

EX. FCO

FCO

HD3

HD3

FCO

1'8" B.F.F.

FCO

FCO

FCO

EX

. 4"

S2.1

9

EX

. 4"

S1.1

9

EX. 4" S9.19

EX

. 4"

S9.1

9

3" S9.19

FCOFCOFCO

FCO

EX. FCO

FCO

3'2" B.F.F.

P-1 P-1 P-1 P-1

P-3

P-1

EX.FD

P-2

P-4

P-4

P-4

P-4

DF1

PROVIDE NEW UNDERSLAB CONNECTION TO GREASE WASTE MAIN AS SHOWN.

HD3

HD3

EX. FCO

HD3

P-7

HD3

EX.SK

FCO

FCO

S8.3

DRAIN TO BE RELOCATED

PIPING TO BE FILLED, CAPPED AND ABANDONED

HD3FCO

HD3

PIPING ROUTED BELOW BEAMS TO ACCOMMODATE VENT

FD1

FIXTURES IN RESTROOM AREA (WATER CLOSETS, LAVATORIES, AND DRINKING FOUNTAIN) TO BE REPLACED WITH NEW SIMILAR FIXTURE IN SAME LOCATION. CONNECT NEW FIXTURE TO EXISTING UTILITIES. TYPICAL.

EX. 4" S2.19EX. 4" S2.19

EX. 6" S1.19EX. 6" S1.19

EX

. 4"

S1.1

9

EX

. 4"

S2.1

9

EX. 6" S1.19

EX. 6" S1.19EX. 4" S2.19

FCOFCO

EX

. 3"

S1.1

9

FCO

FCO

HD3

FCO

FCO

CAP

CAP

REFRIG. PIT

500

P2 2"

V1.1

9

3" S9.19

EX. FD

EX.HD

EX. FD

EX.FCO

3" S2.19

CAP

3" PIPE PENETRATION AT 11" B.F.F.

CAP

CAPCAP

CAP

CAP

FS1

P-8

RELO.SK

FS1

FCO

4" VTR

4" VTR

HD3HD3

FCO

HD3

HD3

HD3

HD3

HD3HD3

EX. 4" S9.19

EX

. 4"

S9.1

9

CAPCAP

CAP

P-8

2" PIPE TO BE ROUTED BELOW GRADE BEAM.

FCOP-1

FD1 P-5

FCO

HD3

3" S9.19

3" S2.19

FCOFCO

FD1FD1

HD3

EX. HD

HD4

HD4

HD3

FCO

FCO

HD3

3" S9.19

3"

S9.1

93"

S9.1

9

3" S

9.19

FCO

FCO

3" S9.19GWI1CAP

FD1

FD1

FD1

EX. FCO

HD3

HD3

P17

P28 P28

P28P28

P28

TYP.

P28

P35

P28

TYP.

HD4

HD4

HD3

TD1

TD1TD1P30

P30

P30

P30

HD3

HD3

HD3

FD1HD4

FD1

FD1

FD1

FD1

FS1

FS1

P-11a

P-8

P28

TYP.

TYP.

P28

FD1

P28

TYP.

P30

P35

HD4 P-7

P35

TD1

TD1 TD1

P29

P29

P-18

P34

4" VTR

P29

4" VTR

P35

P38

P32

EX. FD

HD3

P-7

P37

FS1

FD1

FD1

FD1

HD3

HD3

EX. HD

P28

P28

P38

P28

EX. HD

P28

P38

P38

P38

P28

EX. HD

EX. HD

P28

P33

P33

EX. HD EX. FCO

TD1P29

3/4" S8.3

3/4" S8.3

3/4" S8.3

P31

EX. FD

EX. FD

EX. FD

EX. FD

3/4" S8.33/4" S8.3 TYP.

P31

EX. HD EX. HD EX. HD

P38 P38P38P28 P28

P28P28

1 1/2" V1.193" S1.19

EX. FD

3/4" S8.3

EX. HD

EX. FD

4" S1.19

3" S2.19

P33

1 1/2" V1.19

P32

3/4" S8.3P31

P32

CAP CAPP33

P33

P33

P33

CAP

P32

CAPCAPCAP

S8.3

CAP

P33

P33P33

P33

P33

P-7

2"

V1.1

9

3" S2.19

CAP

EX. 3" S1.19

EX

. 4"

S2.1

9

EX. 6" S1.19

P33

P33

EX. 3" S2.19

4" S2.194" S1.19

HD4P33

S8.3

S8.3

P31

2"

V1.1

9

CAP

P1.14

2" S2.19 CAP EX. FCO

P1.13

P42

GCO

P43

4" S1.19

P39

P47

P48

EX. HD

NOTE: PIPING SERVING ALL HAND SINKS MOUNTED ON COOLER WALLS IS TO BE INSTALLED EXPOSED, FLUSH WITH WALL.

P64

P64

P64

P64

P64

P64

P64

P64P64

P64

P64

P64

P33

P33

P33

P65

P64

P65

P65

P65

P65

P65FD1

P65

P65

P65

P64P65

P65

P51

P51

P51

P51

P51

P65

P65

P64

P51

EX. FCO

P65

P64

P65

P35

P64 CAP

P30

HD3

P51

P29

P29

P29

P64

MEAT PREP

316

SEAFOOD FREEZER

314

REFRIG. PIT

502

SEAFOOD COOLER

313

SEAFOOD PREP

315

2" S2.19 1 1/2" V1.6

3" S2.19

3"

S2.1

9

S8.3 S8.3

3/4

" S

8.3

1 1/2" V1.19

3/4" S8.3

FS1

HD3

FCO

P-8 EX. FS

FCO

S8.3

FD1 FS1

TD1

TD1

TD1

TD1TD1

HD3HD3

TD1

P30

P29

P29

3" VTR

EX. 3" S9.19 EX. 3" S9.19

EX. HD

S8.3

S8.3

3" S2.19

P38

EX. HDEX. HD

P38

EX.FCO

3" S9.19

EX. 4" S9.19EX. 4" S9.19

EX

. 3"

S9.1

9

3"

S9.1

9

P33 P33

EX. HD

S8.3

3" S2.193" S2.19

3"

S2.1

9

3" S2.19

FCO

P41

P29

P29

P32

P32

3" PIPE PENETRATION AT 12" B.F.F. REFER TO STRUCTURAL PLANS FOR DETAILS.

EX. HD

2"

V1.1

9

P31

P35

P28

FCO

EX. 3/4" S8.3

P64

P64

3" S2.19

P65

P51

P29

1 1/2" V1.19

P64

MECHANICAL RM.

400

COMPRESSOR RM.

401

FD1

2" V1.19

3" VTR

EX. 6" S1.19 EX. 6" S1.19

4"

S1.1

9

S8.3

FLORAL COOLER

103

FLORAL PREP

102

UNISEX

105

GROCERY

201

ENTRANCE VESTIBULE

100

P-2

FD4

P-4

HD3HD3

HD3

1 1/2" V1.19

4" VTRP35

P30

P33

P33

2"

S1.1

9

3"

S1.1

9

EX. 4" S2.19

HD3

HD3

3"

S1.1

9

3" S1.19

EX. 6" S1.19

P52

P65

P33

P33

3/32" = 1'-0"1

PLUMBING SANITARY & VENT PLAN - FLOOR - Overall

OWNERSHIP OF INSTRUMENTS OF SERVICE

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by the Consultant as instruments of service shall remain the property of the Consultant. The Consultant shall retain all common law, statutory and other reserved rights, including, without limitation, the copyright thereto.

SHEET NO.

SHEET TITLE

PROJECT NO:

CAD DWG FILE:

DRAWN BY:

CHK'D BY:

DESCRIPTIONDATEMARK

REVISIONS

2211 WINDMAN WAYSUITE 220

FORT MYERS, FL 33901

ARCHITECT

CONSULTANT

SEAL

PROJECT INFO

DATE

2" REFERENCE LINE

WW

W.K

LH

EN

GR

S.C

OM

ME

CH

AN

ICA

L/E

LE

CT

RIC

AL

EN

GIN

EE

RS

1538 A

LE

XA

ND

RIA

PIK

E, S

UIT

E 1

1

FT

. T

HO

MA

S, K

EN

TU

CK

Y 4

1075

800-3

54-9

783 8

59-4

42-8

050

859-4

42-8

058 F

AX

LE

XIN

GT

ON

, K

EN

TU

CK

YLO

UIS

VIL

LE

, K

EN

TU

CK

YC

OLU

MB

US

, O

HIO

NE

W Y

OR

K, N

EW

YO

RK

KO

HR

S L

ON

NE

MA

NN

HE

IL E

NG

INE

ER

S, IN

C.

P1.1

PLUMBINGSANITARY PLAN

PJS

MCD

3-12-2021

A R

EM

OD

EL

FO

R S

TO

RE

#3

8

CONSTRUCTION SET

2851

BE

LLE

CH

AS

SE

HIG

HW

AY

G

RE

TNA

, LA

21871

KEYED NOTES

P2 CONNECT NEW VENT PIPING TO NEAREST EXISTING 2" MINIMUM VENT SYSTEM.

P17 EXISTING CLEANOUT INVERT ELEVATION IS 33" B.F.F.

P28 TIE THE CONDENSATE FROM THIS CASE INTO THE DRAIN OF A SIMILAR ADJACENT CASE ABOVE THE SLAB WITH AIR GAP.

P29 P.C. MUST COORDINATE THE FINAL TRENCH DRAIN LOCATIONS WITH THE FINAL COOLER BOX PLACEMENT/INSTALLATIONSPRIOR TO FINAL CONCRETE POUR. THE TRENCH DRAINS MUST BE FINISHED SMOOTH, IMPERVIOUS, AND EASILYCLEANABLE. REFER TO DETAIL 221319.00-03 ON SHEET P6.1 FOR INSTALLATION. TYP.

P30 REFRIGERATION/FREEZER/FAN COIL CONDENSATE DRAIN. PROVIDE AIR GAP. REFER TO DETAIL 221316.00-03 ANDEVAPORATOR COIL DRAIN DETAIL ON SHEET P6.1 FOR DRAIN INSTALLATION.

P31 PROVIDE HEAT TRACE FOR ALL CONDENSATE PIPING INSIDE OF COOLERS/FREEZERS.

P32 ROUTE WASTE DISCHARGE FROM PREP SINK TO ADJACENT FLOOR SINK. REFER TO DETAIL ON SHEET P6.1 FORINSTALLATION.

P33 HUB DRAIN TO SERVE REFRIGERATED CASE. REFER TO DETAIL 221316.00-03 FOR DRAIN INSTALLATION.

P34 REFER TO DETAIL 224000.00-02 ON SHEET P6.1 FOR MOP SINK INSTALLATION.

P35 REFER TO DETAIL 221313.00-06 FOR VTR INSTALLATION.

P37 EXISTING 3 COMPARTMENT SINK FROM PREVIOUS DELI PREP AREA IS TO BE RELOCATED TO THIS LOCATION.

P38 REWORK EXISTING HUB DRAIN TO SERVE NEW REFRIGERATED CASE. COORDINATE WITH REFRIGERATION PRIOR TOBEGINNING WORK.

P39 EXISTING 3 COMPARTMENT SINK FROM PREVIOUS PRODUCE PREP AREA IS TO BE RELOCATED TO THIS LOCATION.

P41 DRAIN SERVING MEZZANINE AREA ABOVE FOR WATER HEATER RELIEF.

P42 EXISTING FLOOR CLEANOUT TO REMAIN. VERIFY EXACT LOCATION AND RELOCATE IF CONFLICTING WITH NEW WALL.

P43 REPLACE EXISTING GRADE CLEANOUT COVER WITH NEW CLEANOUT CAP. PATCH AND REPAIR EXISTING CONCRETE SLABWITH NEW TO MATCH EXISTING.

P47 EXISTING 3 COMPARTMENT SINK FROM PREVIOUS BAKERY PREP AREA IS TO BE RELOCATED TO THIS LOCATION.

P48 EXISTING HAND SINK FROM PREVIOUS BAKERY PREP AREA IS TO BE RELOCATED TO THIS LOCATION. REFER TO HAND SINKDETAIL ON SHEET P6.1 FOR INSTALLATION.

P51 REFER TO HAND SINK DETAIL ON SHEET P6.1 FOR INSTALLATION (TYPICAL).

P52 WASTE PIPING BELOW CABINETRY IS TO EXTEND AWAY FROM WALL PRIOR TO PENETRATING SLAB IN ORDER TO AVOIDGRADE BEAM.

P64 PROVIDE NEW CLEANOUT. REFER TO DETAIL 221313.00-01 ON SHEET P5.1 FOR INSTALLATION.

P65 REFER TO DETAIL 221316.00-01 FOR FLOOR DRAIN INSTALLATION.

1/4" = 1'-0"2

MEAT PREP

3/32" = 1'-0"3

PLUMBING WASTE AND VENT PLAN - MEZZANINE

GENERAL NOTES

• PLUMBING CONTRACTOR TO FURNISH AND INSTALL PVC SLEEVES SERVING REFRIGERATION PIPING. REFER TO REFRIGERATION DRAWINGS FOR INSTALLATION.

• VERIFY INVERTS AND COORDINATE THE LOCATIONS OF ALL PENETRATIONS IN THE GRADE BEAMS WITH THE STRUCTURAL ENGINEER.

2 4-5-21 ADDENDUM #2

1/4" = 1'-0"4

FLORAL AREA

Plumbing Pipe Type Legend

Mark Color System Name Pipe Material

V1.19

S9.19

S2.19

S1.19

S8.3

V1.6

V7.6

V6.6

CD.6

V1 - Vent

S9 - Indirect Waste

S2 - Grease Waste

S1 - Sanitary

S8 - Condensate Drainage

V1 - Vent

V7 - Exhaust Air Flue Vent

V6 - Intake Air Flue Vent

- Condensate Drainage

19 - PVC - Schedule 40 - ASTM D1785/D2665

19 - PVC - Schedule 40 - ASTM D1785/D2665

19 - PVC - Schedule 40 - ASTM D1785/D2665

19 - PVC - Schedule 40 - ASTM D1785/D2665

3 - Copper - DWV - ASTM B306

6 - PVC - Schedule 40 - ASTM D1785

6 - PVC - Schedule 40 - ASTM D1785

6 - PVC - Schedule 40 - ASTM D1785

6 - PVC - Schedule 40 - ASTM D1785

2