Operating Instructions

KRAL Sensors.Series BEG 56 and BEG 47C.

OII 05enEdition 11/2008

2 OII 05en Edition 11/2008 Operating Instructions

Table of contents

KR

AL

Sen

sors

– S

erie

s B

EG

56

and

BE

G 4

7C

About this document

General information 3

Target groups 3

Symbols used 3

Danger levels 3

Further applicable documents 3

General safety instructions 4

Function description

Description 5

Functional principle 5

Overview of specifications 6

Technical data

Intended use 7

Use not as intended 7

Operational limits 7

Data sheet BEG 56 8

Data sheet BEG 47C 9

Transportation, storage and disposal

Unpacking and checking the state of delivery 10

Transportation 10

Storage 10

Disposal 10Safety instruction for disposal 10Disposing of the sensor 10

Installation, removal and connection

Safety instructions on installation, removal and connection 11

Installation, removal and connection BEG 56 12

Installing and connecting BEG 56 12Connecting the extension cable 13Removing BEG 56 13

Installation, removal and connection BEG 47C 14

Installing and connecting BEG 47C 14Removing BEG 47C 15

Troubleshooting

Information about faults 16Possible faults 16Troubleshooting 16

Appendix

General drawings 17

Spare parts 17

Notes 18

Operating Instructions OII 05en Edition 11/2008 3

General information

Abo

ut th

is d

ocum

ent

About this document General information

The operating instructions form part of the sensor and must be kept for future reference.

Target groups

Symbols used

Danger levels

Further applicable documents

Target group Tasks

Operator-owner Keep these instructions available at the installation site for future reference.

Ensure that employees read and observe these instructions and the associated documents, in particular the safety instructions and warnings.

Observe additional plant-specific directives and regulations.

Specialist personnel, fitters Read, observe and follow these instructions and the associated documents, in particular the safety instructions and warnings.

Symbol Meaning

Warning

Mechanical installation procedures

Electrical installation procedures

Check or fault table

➤ Request for action

Warning Danger level Consequences of non-observances

Caution Potentially dangerous situation Material damage, slight personal injury

Warning Possible threat of danger Serious personal injury, invalidity

Danger Immediate threat of danger Serious personal injury, death

Declaration of conformity as per EU Directive 73/23/EEC respectively 89/336/EEC and 76/117/EEC (BEG 56)

Declaration of conformity as per EU Directive 89/336/EEC respectively 94/9/EC (BEG 47C)

Manufacturer's declaration to EU Directive 94/9/EC (BEG 47C)

Corresponding manufacturer data sheet

Corresponding manufacturer operating instructions

Corresponding operating instructions for volumeter

Corresponding operating instructions for electronic equipment

4 OII 05en Edition 11/2008 Operating Instructions

General safety instructions

Abo

ut th

is d

ocum

ent

General safety instructions

The following general safety instructions must be observed:

No liability is accepted for damage arising through non-observance of the operating

instructions.Read the operating instructions carefully and observe them.

The operator-owner is responsible for the observance of the operating instructions.

Installation, removal and installation work may only be carried out by specialist personnel.

Do not use KRAL sensors outside the operational limits specified in the "Technical data" section. In the case of operating data that do not agree with the specifications in the "Technical

data" section, contact the manufacturer. In order for the warranty to remain valid, corrective maintenance during the warranty period require the express permission of the manufacturer.

Observe the general regulations for the prevention of accidents as well as the local safety and operating instructions.Observe the valid national and international standards and specifications of the installation

location.Implement all the supply lines without faults.The sensor system (sensor, transducer and lines) may not be located in the area of strong,

high-frequency electromagnetic fields, such as those emitted e.g. from power lines, electric motors, frequency converters, etc. This can lead to erroneous measurements or the destruction of the sensor system.

In case of plants with an increased potential of danger to humans and/or machines the failure of a sensor may not lead to injuries or damage to property.

Always equip systems with an increased potential of danger with alarm equipment.Maintain and check the protective/alarm equipment regularly.

The pumped liquids may be dangerous (for example hot, dangerous to health, poisonous,

combustible). Observe the safety regulations for handling dangerous materials.Pumped liquids can be subject to high pressure and can cause damage and/or personal injury

should leaks occur.Depending on operating conditions, the service life of the sensors is limited due to vibrations, temperature influences or deterioration. The operator-owner is responsible for regular

inspection.All parts which jeopardize safe operation must be replaced regularly.

Abnormal operating mode or visible damage prohibits further use.

Operating Instructions OII 05en Edition 11/2008 5

Description

Fun

ctio

n de

scrip

tion

Function description Description

Functional principle

The sensors from the BEG 56 and BEG 47C series are optimized for use in combination with KRAL volumeters of the OME series. The sensor samples the flanks of the measuring screw and generates a specific number of pulses per

flow volume unit - depending on the size and working point. This device-specific characteristic is called the K-factor (unit: Pulse/Liter) and can be found on the rating plate of the volumeter and the enclosed calibration certificate.

On sensor plug 3 of the sensor BEG 56 there are a green and a yellow LED. The supply voltage can be checked using the green LED. Upon rotation of the measuring screws, the yellow LED begins to flash in the rhythm of the pulse signal and thus facilitates a control of the signal output.

The sensor insert of the BEG 47C is mounted in a dry sleeve 5 . The dry sleeve allows the sensor insert to be mounted without contact to the liquid to be measured.

Fig. 1 BEG 56 design

Fig. 2 BEG 47C design

123

Sensor insertHexagon nut

Sensor plug

456

Sensor cableDry sleeve

Tensioning nut

1 2 3 4

1 5 6

6 OII 05en Edition 11/2008 Operating Instructions

Overview of specifications

Fun

ctio

n de

scrip

tion

Overview of specifications

Tab. 1 Sensor specifications

BEG 56 BEG 47C

Use with KRAL volumeter of the series

OME OME

Application Standard Chemically resistantExplosion hazard area

K-Factor K1 K1

Signal form PNP Namur

Mode of functioning Hall effect, single Inductive

max. pressure [bar] 40 40

Temperature range [°C] -40...+125 -25...+100

Connection thread M12x1 M16x1

Mounting Without dry sleeve With dry sleeve

Casing material Stainless steel 1.4305 PVDF

Material of the dry sleeve – Stainless steel 1.4401 / ceramic

Operating Instructions OII 05en Edition 11/2008 7

Intended use

Tec

hnic

al d

ata

Technical data Intended use

KRAL Sensors of the BEG 56 and BEG 47C series are intended exclusively for use with KRAL

volumeters of the OME series. The sensors may only be used within the operational limits described within this chapter.

Use not as intended

The sensors are not suitable for all other use except for use with KRAL volumeters. The sensors may not be used outside the operational limits described within this chapter. Operating data which deviate from the values can lead to damage. If there is any doubt whether deviating operating data can cause

damage, inform the manufacturer.

Operational limits

The following table indicates the operational limits of the sensors which may not be exceeded.

BEG 56 BEG 47C

max. pressure [bar] 40 40

Temperature [°C]min. – max. -40...+125 -25...+100

Voltage range [V DC]Area with no explosion hazard

Explosion hazard area

10 – 30

5 – 25

8

8 OII 05en Edition 11/2008 Operating Instructions

Data sheet BEG 56

Tec

hnic

al d

ata

Data sheet BEG 56

Specification Unit Data

Electrical specification

Principle of operation Hall effect, single

OutputConnection

max. load current [mA]

PNP

50

Frequency range [kHz] 0 – 15

Voltage range [V DC] 10 – 30

Current consumption (without load) [mA] ≤ 10

Fall of voltage [V] ≤ 3

Short-circuit and reverse voltage protection No

Mechanical specification

Range of applicationLiquid temperatureAmbient temperature

[°C][°C]

-40...+125-25...+90

Casing material Stainless steel 1.4305

Connection type Straight plug with LED (3-pin)

Cable jacket PUR non halogen

Wire cross-section [mm2] 3 x 0,34

Cable diameter [mm] 5,2

Cable length [m] 3

Degree of protection IP 65

Tightening torque for hexagon nut [Nm] 7

Connection circuit diagram Plug assignment

1 brown

4 black3 blue

View of socket side

M12x1

40

4 1

Ø12

Ø14,8

45

PNP

Signal

Gnd

B+U 10 - 30 V DC1

4

3

1 ... braun / brown4 ... schwarz / black3 ... blau / blue

3 4

1

Operating Instructions OII 05en Edition 11/2008 9

Data sheet BEG 47C

Tec

hnic

al d

ata

Data sheet BEG 47C

Specification Unit Data

Electrical specification

Principle of operation Inductive

OutputConnection

Explosion hazard areaInternal resistance RiNominal voltage

Area with no explosion hazardOperating voltage

[kΩ][V DC]

[V DC]

Namur opener EN 60947-5-6

18,2

5 – 25

Frequency range [Hz] 0 – 2000

Short-circuit and reverse voltage protection Yes

Mechanical specification

Range of applicationLiquid temperature

max. pressure on the face

[°C]

[bar]

-25...+100

40

Casing material, sensor PVDF

Casing material, dry sleeve 1.4401 / ceramic

Cable jacket PVC

Wire cross-section [mm2] 2 x 0,34

Cable diameter [mm] 4,8

Cable length [m] 2

Degree of protection IP 68

General information

Use in explosion hazard area EN 50014:1997, EN 50020:1994

Ex marking II 1G EEx ia IIC T6II 2G EEx ia IIC T6

Connection circuit diagram

M16x1

50

36,5

Ø11

6013

1 ... braun / brown schwarz / black3 ... blau / blueRi 1 kΩ

1

-3

+ 8,2 V DC

10 OII 05en Edition 11/2008 Operating Instructions

Unpacking and checking the state of delivery

Tra

nspo

rtat

ion,

sto

rage

and

dis

posa

l

Transportation, storage and disposal Unpacking and checking the state of delivery

1. On delivery unpack the sensor and check for damage during transportation.

2. Report damage during transportation immediately to the manufacturer.3. Dispose of packing material in accordance with the locally applicable regulations.

Transportation

1. If possible, transport sensor in original packaging.2. Do not kink sensor cable.

Storage

➤ If possible, store the sensor in original packaging in a cool and dry place.

Disposal

Safety instruction for disposal

Disposing of the sensor

➤ Dispose of the sensor as electronic waste.

Note the following on disposal:

Observe the local regulations on disposal.

Operating Instructions OII 05en Edition 11/2008 11

Safety instructions on installation, removal and connection

Inst

alla

tion,

rem

oval

and

con

nect

ion

Installation, removal and connection Safety instructions on installation, removal and connection

The following safety instructions must be observed:

All installation and removal work may only be carried out by qualified personnel.

The following qualifications are required for the electrical connection:Practical electrotechnical trainingKnowledge of the safety guidelines at the workplace

Knowledge of the electrotechnical safety guidelines

The sensor system (sensor, transducer and lines) may not be located in the area of strong, high-frequency electromagnetic fields. This could lead to erroneous measurements or even to the destruction of the sensor system.

➤ The connecting lines of the sensor connections are to be shielded and laid separately from the

supply and measuring lines.➤ Ensure that the supply voltage is correct.

12 OII 05en Edition 11/2008 Operating Instructions

Installation, removal and connection BEG 56

Inst

alla

tion,

rem

oval

and

con

nect

ion

Installation, removal and connection BEG 56

Installing and connecting BEG 56

Fig. 1 General drawing BEG 56

493624.1

Sensor plugSensor insert

624.2 Hexagon nut

Fig. 2 Mounting BEG 56 Fig. 3 Terminal diagram BEG 56

624.1

624.2

493

624.1

493

PNP

Signal

Gnd

B+U 10 - 30 V DC1

4

3

1 ... braun / brown4 ... schwarz / black3 ... blau / blue

DANGERRisk of death resulting from electric shock

➤ The sensor may only be connected by an authorized electrician.➤ Connect the sensor to the correct supply voltage, see terminal diagram BEG 56, Fig. 3.

CAUTIONFaulty wiring destroys the sensor.

➤ Wire the sensor according to terminal diagram and plug assignment, see "Data sheet BEG 56",

page 8.

Operating Instructions OII 05en Edition 11/2008 13

Installation, removal and connection BEG 56

Inst

alla

tion,

rem

oval

and

con

nect

ion

1. Clean the sensor hole.2. Remove the protective cap of the sensor.

3. Screw the sensor insert 624.1 into the sensor hole until it is flush.4. Tighten the hexagon nut 624.2, max. tightening torque 7 Nm.5. Insert the sensor plug 493, tighten knurled nut by hand.

- or, for a pre-mounted sensor -➤ Remove the protective cap of the sensor,

insert sensor plug 493, tighten knurled nut by hand.➤ Connect the sensor cable in accordance with the terminal diagram.

Connecting the extension cable

Normally the line length does not influence the functional efficiency of the sensor. However, we recommend not extending the connection cable of the sensor beyond a maximum length of 100 m. Extension cable as well as cable plug and cable box are available as accessories from KRAL.

1. Solder cable plug to the sensor cable.

2. Solder cable box to the extension cable3. Connect sensor cable and extension cable.4. Connect extension cable in accordance with the terminal diagram.

Removing BEG 56

1. Loosen knurled nut of the sensor plug 493 .

2. Pull out sensor plug.3. Loosen hexagon nut 624.2.

4. Screw out sensor insert 624.1 .

Pay attention to the following when connecting the extension cable:

➤ Use only a shielded cable.➤ The wire cross-section must be at least 3 x 0,25 mm2 .➤ Lay the cable separately from the supply and measuring lines, see "Safety instructions on

installation, removal and connection", page 11.

14 OII 05en Edition 11/2008 Operating Instructions

Installation, removal and connection BEG 47C

Inst

alla

tion,

rem

oval

and

con

nect

ion

Installation, removal and connection BEG 47C

Installing and connecting BEG 47C

Fig. 4 General drawing BEG 47C

624.1624.3626.1

Sensor insertSpring

Dry sleeve

626.2739

Tensioning nutO-ring

Fig. 5 Mounting BEG 47C Fig. 6 Terminal diagram BEG 47C

739

626.1

624.1

624.3

626.2

626.1

624.1

624.3626.2

1 ... braun / brown schwarz / black3 ... blau / blueRi 1 kΩ

1

-3

+ 8,2 V DC

Operating Instructions OII 05en Edition 11/2008 15

Installation, removal and connection BEG 47C

Inst

alla

tion,

rem

oval

and

con

nect

ion

1. Clean sensor hole.

2. Insert O-ring 739 into the sensor hole.3. Screw dry sleeve 626.1 into the sensor hole by hand until it is flush.4. Push sensor insert 624.1 and spring 624.3 into the dry sleeve and tighten the tightening nut 626.2 by

hand until it is flush.- or, for a pre-mounted dry sleeve -➤ Remove protective cap of the dry sleeve 626.1,

push sensor insert 624.1 and spring 624.3 into the dry sleeve, tighten tightening nut 626.2 by hand until it is flush.

➤ Connect sensor cable in accordance with the terminal diagram.

Removing BEG 47C

1. Separate sensor cable from the supply voltage.2. Loosen tightening nut 626.2 and pull out sensor insert 624.1 and spring 624.3 from the dry sleeve

626.1 .3. Screw dry sleeve out of the sensor hole.4. Remove O-ring 739 from the sensor hole.

DANGERDanger of life through electric shock

➤ The sensor may only be connected by authorized electrical personnel.

➤ Connect the sensor to the correct supply voltage, see terminal diagram BEG 47C.

16 OII 05en Edition 11/2008 Operating Instructions

Information about faults

Tro

uble

shoo

ting

Troubleshooting Information about faults

Faults can have different causes. The following tables lists the symptoms of a fault, the possible causes

and measures for elimination.

Possible faults

Troubleshooting

Tab. 1 Fault table

Fault Cause / Remedy

no signal 1, 2, 3, 4, 5, 6, 8

incorrect signal 1, 2, 6, 7

No. Cause Remedy

1 Sensor defective ➤ Screw out sensor and check:

A functioning sensor sends a pulse out when approaching a ferromagnetic part.BEG 56: Check functional capability of the sensor

using the light-emitting diodes in the sensor plug, see "Functional principle", Page 5.

➤ Replace sensor.

2 Sensor mounted incorrectly ➤ Check sensor mounting, see "Installation, removal

and connection", Page 11.

3 Incorrect connection ➤ Check connections.➤ BEG 56: Check light-emitting diodes,

see "Functional principle", Page 5.

4 Volumeter does not work ➤ Check and actuate the volumeter, see the

corresponding volumeter operating instructions.

5 Incorrect power supply ➤ Adjust electronic device, see the corresponding operating instructions for electronic equipment.

6 Corroded contacts ➤ Check and clean contacts.

7 Interference from outside ➤ Lay cables accordingly, see "Safety instructions on

installation, removal and connection", Page 11.

8 No flow ➤ Check piping system.

Operating Instructions OII 05en Edition 11/2008 17

General drawings

App

endi

x

Appendix General drawings

Spare parts

Tab. 1 Overview of spare parts

Fig. 1 Exploded view BEG 56

Fig. 2 Exploded view BEG 47C

Spare part number

Part Spare part number

493 Sensor plug 626.1 Dry sleeve

624.1 Sensor insert 626.2 Tensioning nut

624.2 Hexagon nut 739 O-ring

624.3 Spring

* These parts are only supplied as a unit

624.1*

624.2*

493

739

626.1

624.1*

624.3*

626.2*

18 OII 05en Edition 11/2008 Operating Instructions

Notes

App

endi

x

Notes

Operating Instructions OII 05en Edition 11/2008 19

Notes

App

endi

x

KRAL AG, Bildgasse 40, Industrie Nord, 6890 Lustenau, Austria,Tel.: +43 / 55 77 / 8 66 44 - 0Fax: +43 / 55 77 / 8 84 33, www.kral.at, E-Mail: [email protected]