Upload
eka-group
View
239
Download
10
Tags:
Embed Size (px)
DESCRIPTION
MasterBook_2
Citation preview
Master BookENG
3
PAGE PAGE
STANDARD LINE 5 METAL LINE 45
PLNAB-PLNAM 6 PLNAR0 46PLNAV 7 PLTMR0 47PLTMB-PLTMM 8 P30SS/W 48PLTMV 9 PLTMMF 49PG6AB-PG6AM 10 PG3AR0 50PG3AB-PG3AM 11 PG6AR0 51PW4AB-PW4AM 12PG6AV 13 SUBSTRUCTURE 53
PG3AV 14PW4AV 15 MPS Description 54
MPS Technical data 55
HIGH CLASS 17 MPL Description 56MPL Technical data 57
PLTMMH 60x60 18 MPM Description 58PLTMMH 30x30 19 MPM Technical data 59PLTMVH 60x60 20 MPH Description 60PLTMVH 30x30 21 MPH Technical data 61PG6AMH 60x60 22 MPC Description 62PG6AMH 30x30 23 MPC Technical data 63PG3AMH 60x60 24 SSH Description 64PG3AMH 30x30 25 SSH Technical data 65PG6AVH 60x60 26 MP super high 66PG6AVH 30x30 27 MP super high slim 67PG3AVH 60x60 28PG3AVH 30x30 29PG1AVZ 30PG2AVZ 31PG2AVQ 32
PLTMMW 33PLTMVW 34PG2AVH 60x60 35PG2AVH 30x30 36PG6AMW 37PG6AVW 38PG3AMW 39PG3AVW 40PW4AMW 41PBAT/PBAO 42
INDEX
4
5
Standard Line
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
6
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panels
PLNAB-PLNAM
Legend standard EN 12825 Prospectus 1
• Core made of high density chipboard and thermosetting resins, 28 mm thick.• Aluminium foil lower surface 0.05 mm thick.• The top surface can be of various covering materials.• PVC edge trim, 0.45 mm thick, ensuring air tightness and no squeaking.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: Variouscore: chipboard
FIELDS OF APPLICATION: Offices, EDPs, control rooms, laboratories, with light-medium load bearing requirements.
APPLICATION NOTES:Suitable for homogeneous vinyl, rubber, linoleum, carpet and loose lay covering material (PLNAB0).
Chipboard corecEdge
b Covering
eBottom surface
a
a
600
600
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Various ~30 0.05-2 28 0.05 ~8.5 30 1 ≤2x1010 >30 0.17
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 1.00 1.50 2.30 2.80 1.50 7.50 10.00 16.00 19.00 10.00
Ultimate load kN(4) 3.1 3.5 4.8 5.5 3.5EN 12825 - - 1A2 1A2 -
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
7
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
Panel
PLNAV• Core made of high density chipboard and thermosetting resins, 28 mm thick.• Galvanized steel tray lower surface approx. 0.4 mm thick.• The top surface can be of various covering materials.• PVC edge trim, 0.45 mm thick, ensuring air tightness and no squeaking.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: Variouscore: chipboard
FIELDS OF APPLICATION: Offices, EDPs, control rooms, laboratories, with light-medium load bearing requirements.
APPLICATION NOTES:Suitable for homogeneous vinyl, rubber, linoleum, plastic laminate, carpet and loose lay covering material (PLNAVA).
EdgeChipboard core
Covering
e
c
b
a
Bottom surface
600
a
600
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Various 28.5-30-5 0.05-2 28 ~0.4 ~10 15 1 ≤2x1010 >30 0.17
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 1.70 2.20 3.30 4.30 2.20 12.00 16.00 22.00 26.00 16.00
Ultimate load kN(4) 3.8 4.1 5.4 6.1 4.1EN 12825 - 1A2 1A2 2A2 1A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
Legend standard EN 12825 Prospectus 1
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
8
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panels
PLTMB-PLTMM• Core made of high density chipboard and thermosetting resins, 38 mm thick.• Aluminium foil lower surface 0.05 mm thick.• The top surface can be of various covering materials.• PVC edge trim, 0.45 mm thick, ensuring air tightness and no squeaking.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: Variouscore: chipboard
FIELDS OF APPLICATION: Offices, EDPs, control rooms, laboratories, with medium load bearing requirements.
APPLICATION NOTES:Suitable for homogeneous vinyl, rubber, linoleum, plastic laminate, carpet and loose lay covering material (PLTMB).
Chipboard corecEdge
b Covering
eBottom surface
a
a
600
600
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Various ~38-40 0.05-2 38 0.05 ~11 45 1 ≤2x1010 >32 0.17
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.00 2.60 3.60 4.20 2.60 13.00 17.00 23.00 27.00 17.00
Ultimate load kN(4) 5.1 5.4 6.4 6.8 5.4EN 12825 1A2 1A2 2A2 2A2 1A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
9
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PLTMV• Core made of high density chipboard and thermosetting resins, 38 mm thick.• Galvanized steel tray lower surface approx. 0.4 mm thick.• The top surface can be of various covering materials.• PVC edge trim, 0.45 mm thick, ensuring air tightness and no squeaking.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: Variouscore: chipboard
FIELDS OF APPLICATION: Offices, EDPs, control rooms, laboratories, with medium/high load bearing requirements.
APPLICATION NOTES:Suitable for homogeneous vinyl, rubber, linoleum, plastic laminate, carpet and loose lay covering material.
EdgeChipboard core
Covering
e
c
b
a
Bottom surface
600
a
600
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Various 38.5-40.5 0.05-2 38 0.4 ~11 30 1 ≤2x1010 >32 0.17
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.0 3.5 4.5 5.0 3.5 21.00 23.00 31.00 35.00 23.00
Ultimate load kN(4) 6.5 6.9 7.8 8.2 6.9EN 12825 2A2 2A2 2A2 3A2 2A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
10
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panels
PG6AB-PG6AM
covering: Variouscore: inert Material
• Core made of high density calcium sulphate and organic fibres, 30 mm thick, primerized on both upper and lower surfaces (PG6A0).
• It is also available with aluminium foil 0.05 mm thick on bottom surface (PG6AM), or on both upper and lower surface (PG6AB0).
• PVC edge trim 0,6 mm thick, ensuring air tightness and no squeaking.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Various ~30-32 0.05-2 30 - ~16 60 1 ≤2x1010 >34 0.41
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.40 3.10 3.80 4.20 3.10 18.00 22.00 28.00 32.00 22.00
Ultimate load kN(4) 6.6 7.1 7.9 8.3 7.1EN 12825 2A2 2A2 2A2 3A2 2A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
Calcium sulphatecore
cEdge
b Covering
eBottom surface
a
a
600
600
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Offices, EDPs, control rooms, technical rooms with medium/high load bearing requirements and any room with particular fire resistance rate.
APPLICATION NOTES:Suitable for homogeneous vinyl, rubber, linoleum, plastic laminate, carpet and loose lay covering material (PG6A00-PG6AB0).
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
11
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panels
PG3AB-PG3AM• Core made of high density calcium sulphate and organic fibres, 34 mm thick,
primerized on both upper and lower surfaces (PG3A0);• It is also available with aluminium foil 0.05 mm thick on bottom surface
(PG3AM), or on both upper and lower surface (PG3AB0);• PVC edge trim 0,6 mm thick, ensuring air tightness and no squeaking.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: Variouscore: inert Material
FIELDS OF APPLICATION: Offices, EDPs, control rooms, technical rooms with medium/high load bearing requirements and any room with particular fire resistance rate.
APPLICATION NOTES:Suitable for homogeneous vinyl, rubber, linoleum, plastic laminate, carpet and loose lay covering material (PG3A00-PG3AB0).
Calcium sulphatecore
cEdge
b Covering
eBottom surface
a
a
600
600
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.0 3.5 4.5 5.0 3.5 23.00 27.00 31.00 35.00 25.00
Ultimate load kN(4) 8.1 8.6 9.7 10.1 8.6EN 12825 2A2 3A2 4A2 5A2 3A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Various 34-36 0.05-2 34 0.05 ~19 90 1 ≤2x1010 >38 0.41
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
12
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panels
PW4AB-PW4AM• Core made of high density chipboard and thermosetting resins, 28 mm thick matched to a
high density calcium sulphate and organic fibres board 12.5 mm thick;• Aluminium foil lower surface 0.05 mm thick;• The top surface can be of various covering materials;• It is also available with aluminium foil 0.05 mm thick on both upper and lower sides (PW4AB0);• PVC edge trim, 0.45 mm thick, ensuring air tightness and no squeaking.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: Variouscore: chipboard+inert Material
FIELDS OF APPLICATION: Offices, EDPs, control rooms, laboratories, with medium load bearing requirements and any room with high fire resistance rate.
APPLICATION NOTES:Suitable for homogeneous vinyl, rubber, linoleum, plastic laminate, carpet and loose lay covering material (PW4AB0).
Calcium sulphate
Covering
c
d
Bottom surface
Chipboard core
Edge
a
600
a
e
b
core
600
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.30 2.80 4.0 4.8 2.8 16.00 19.00 25.00 30.00 19.00
Ultimate load kN(4) 4.7 5.5 7.5 8.8 5.5EN 12825 1A2 1A2 2A2 3A2 1A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c d e kg REI CSE/RFclasse Ω dB W/m °C
Various 40.5-42.5 0.05-2 28 12.5 0.05 ~14 60 1 ≤2x1010 >34 0.17/0.41
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
13
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
covering: Variouscore: chipboard+inert Material
Panel
PG6AV• Core made of high density calcium sulphate and organic fibres, 30 mm thick.• Galvanized steel tray lower surface 0.4 mm thick.• The top surface can be of various covering materials.• PVC edge trim 0,6 mm thick, ensuring air tightness and no squeaking.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Various 30.5-32.5 0.05-2 30 ~0.4 ~17 45 1 ≤2x1010 >34 0.41
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 4.00 4.50 5.2 5.6 4.5 20.00 25.00 30.00 35.00 25.00
Ultimate load kN(4) 8.0 9.0 10.2 11.0 9.0EN 12825 3A2 4A2 5A2 5A2 4A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Offices, EDPs, control rooms, technical rooms, laboratories, with medium load bearing requirements.
APPLICATION NOTES:Suitable for homogeneous vinyl, rubber, linoleum, plastic laminate, carpet and loose lay covering material (PG6AVA).
covering: Variouscore: inert Material
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
Edge Calcium sulphatecore
Covering
e
c
b
a
Bottom surface
600
a
600
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
14
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG3AV• Core made of high density calcium sulphate and organic fibres, 34 mm thick.• Galvanized steel tray lower surface 0.4 mm thick.• The top surface can be of various covering materials.• PVC edge trim 0,6 mm thick, ensuring air tightness and no squeaking.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: Variouscore: inert Material
FIELDS OF APPLICATION: Offices, EDPs, control rooms, technical rooms, laboratories, with medium load bearing requirements.
APPLICATION NOTES:Suitable for homogeneous vinyl, rubber, linoleum, plastic laminate, carpet and loose lay covering material (PG3AVA).
Edge Calcium sulphatecore
Covering
e
c
b
a
Bottom surface
600
a
600
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 5.0 5.5 6.0 6.5 5.5 29.00 34.00 39.00 45.00 34.00
Ultimate load kN(4) 9.8 10.5 12.0 13.0 9.27EN 12825 4A2 5A2 6A2 6A2 5A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Various 34.5-36.5 0.05-2 34 0.5 ~20 60 1 ≤2x1010 >38 0.41
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
15
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PW4AV• Core made of high density chipboard and thermosetting resins, 28 mm thick matched to a
high density calcium sulphate and organic fibres board 12.5 mm thick;• Galvanized steel on tray lower surface 0.4 mm thick;• The top surface can be of various covering materials;• PVC edge trim, 0.45 mm thick, ensuring air tightness and no squeaking.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: Variouscore: chipboard+inert Material
FIELDS OF APPLICATION: Offices, EDPs, control rooms, laboratories, with medium load bearing requirements.
APPLICATION NOTES:Suitable for homogeneous vinyl, rubber, linoleum, plastic laminate, carpet and loose lay covering material.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.3 3.8 4.2 5.0 3.8 22.00 24.00 32.00 36.00 24.00
Ultimate load kN(4) 7.0 7.5 8.3 9.0 7.5EN 12825 2A2 2A2 3A2 3A2 2A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
Calcium sulphate
Covering
Chipboard corec
d
Bottom surface
Edge
a
600
600
a
e
b
core
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c d e kg REI CSE/RFclass Ω dB W/m °C
Various ~41-43 0.05-2 28 12.5 0.4 ~15,5 45 1 ≤2x1010 >38 0.17/0.41
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
16
17
High Class
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
18
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PLTMMH 60x60
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.50 3.00 4.00 4.50 3.00 17.00 20.00 25.00 30.00 20.00
Ultimate load kN(4) 4.2 4.6 5.3 5.8 4.6EN 12825 1A2 1A2 1A2 1A2 1A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
• Core made of high density chipboard and thermosetting resins, 38 mm thick.• Aluminium foil lower surface 0.05 mm thick.• Gres of ceramic 8-11 mm thick, 60 x 60 cm on top surface.• Grey plastic semi rigid edge trim 1.5 or 2.5 mm thick ensuring air tightness and no squeaking.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Gres of ceramic ~46-49 8-11 38 0.05 ~19 45 1 Antistatic >32 0.17/3.200
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: ceramiccore: chipboard
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
a
a
600
600 Edge
Bottom surface
e
Covering
Chipboard corec
b
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
19
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PLTMMH 30x30
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.00 2.60 3.60 4.20 2.60 13.00 17.00 23.00 27.00 17.00
Ultimate load kN(4) 5.1 5.4 6.4 6.8 5.4EN 12825 1A2 1A2 2A2 2A2 1A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
• Core made of high density chipboard and thermosetting resins, 38 mm thick;• Aluminium foil lower surface 0.05 mm thick;• Gres of ceramic top surface covering 8-9 mm thick, 30 x 30 cm;• Grey plastic semirigid edge trim 1.5 or 2.5 mm thick, ensuring air tightness and no squeaking;• Central gap plastic material 3 or 5 mm thick.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Gres of ceramic ~46-49 8-9 38 0.05 ~19 45 1 Antistatic >32 0.17/3.200
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: ceramiccore: chipboard
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
Edgea
600
a
600
c
Bottom surface
e
Coveringb
Central gap
Chipboard core
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
20
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PLTMVH 60x60
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.80 4.60 5.10 6.10 4.60 25.00 29.00 33.00 36.00 29.00
Ultimate load kN(4) 5.3 5.7 6.3 6.7 5.7EN 12825 1A2 1A2 2A2 2A2 1A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
• Core made of high density chipboard and thermosetting resins, 38 mm thick.• Galvanized steel tray on lower surface 0.4 mm thick.• Gres of ceramic 8-11 mm thick, 60 x 60 cm on top surface.• Grey plastic semi rigid edge trim 1.5 or 2.5 mm thick ensuring air tightness and no squeaking.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Gres of ceramic ~46.5-49.5 8-11 38 0.4 ~20 30 1 >1011 >32 0.17/3.200
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: ceramiccore: chipboard
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
Chipboard coreEdge
Coveringb
c
e
a
a60
0
600
Bottom surface
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
21
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PLTMVH 30x30
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.00 3.50 4.50 5.00 3.50 21.00 23.00 31.00 35.00 23.00
Ultimate load kN(4) 6.5 6.9 7.8 8.2 6.9EN 12825 2A2 2A2 2A2 3A2 2A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
• Core made of high density chipboard and thermosetting resins, 38 mm thick;• Galvanized steel tray on lower surface 0.4 mm thick;• Gres of ceramic top surface covering 8-9 mm thick, 30 x 30 cm;• Grey plastic semirigid edge trim 2.5 mm thick, ensuring air tightness and no squeaking;• Central gap plastic material 5 mm thick.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Gres of ceramic ~46.5-49.5 8-9 38 0.4 ~20 30 1 >1011 >32 0.17
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: ceramiccore: chipboard
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
600
600
a
a Edge
e
c
b
Central gap
Covering
Chipboard core
Bottom surface
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
22
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG6AMH 60x60
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.00 3.60 4.00 4.60 3.60 12.00 16.00 21.00 26.00 16.00
Ultimate load kN(4) 7.1 7.5 8.6 9.3 7.5EN 12825 2A2 2A2 3A2 4A2 2A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
• Core made of high density calcium sulphate and organic fibres, 30 mm thick.• Aluminium foil lower surface 0.05 mm thick.• Gres of ceramic top surface covering 8-11 mm thick, 60 x 60 cm.• Grey plastic semirigid edge trim 1.5 or 2.5 mm thick, ensuring air tightness and no squeaking.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Gres of ceramic ~38-41 8-11 30 0.05 ~24 60 1 Antistatic >34 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: ceramiccore: inert Material
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
c
b
e
a
a
600
600 Edge
Covering
Bottom surface
Calcium sulphatecore
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
23
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG6AMH 30x30
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.40 3.10 3.80 4.20 3.10 12.00 16.00 21.00 26.00 16.00
Ultimate load kN(4) 6.6 7.1 7.9 8.3 7.1EN 12825 2A2 2A2 2A2 3A2 2A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
• Core made of high density calcium sulphate and organic fibres, 30 mm thick.• Aluminium foil lower surface 0.05 mm thick.• Gres of ceramic top surface covering 8-9 mm thick, 30 x 30 cm.• Grey plastic semirigid edge trim 1.5 or 2.5 mm thick, ensuring air tightness and no squeaking;• Central gap plastic material 3 or 5 mm thick.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Gres di ceramica ~38-39 8-9 30 0.05 ~24 60 1 Antistatic >34 0.41/3.200
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: ceramiccore: inert Material
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
a
600
a
600
c
e
b
Central gap
Bottom surface
Edge
Covering
Calcium sulphatecore
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
24
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG3AMH 60x60
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.60 4.40 4.90 5.60 4.40 24.00 28.00 33.00 37.00 28.00
Ultimate load kN(4) 9.1 9.6 10.7 11.1 9.6EN 12825 3A2 4A2 5A2 5A2 4A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
• Core made of high density calcium sulphate and organic fibres, 34 mm thick.• Aluminium foil lower surface 0.05 mm thick.• Gres of ceramic top surface covering 8-11 mm thick, 60 x 60 cm.• Grey plastic semirigid edge trim 1.5 or 2.5 mm thick, ensuring air tightness and no squeaking.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Gres of ceramic ~42-45 8-11 34 0.05 ~26 90 1 Antistatic >38 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
c
b
e
a
a
600
600
Covering
Calcium sulphatecore
Bottom surface
Edge
covering: ceramiccore: inert Material
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
25
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG3AMH 30x30
covering: ceramiccore: inert Material
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.00 3.50 4.50 5.00 3.50 24.00 28.00 33.00 37.00 28.00
Ultimate load kN(4) 8.1 8.6 9.7 10.1 8.6EN 12825 3A2 3A2 4A2 5A2 3A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
• Core made of high density calcium sulphate and organic fibres, 34 mm thick.• Aluminium foil lower surface 0.05 mm thick.• Gres of ceramic top surface covering 8-9 mm thick, 30 x 30 cm. • Grey plastic semirigid edge trim 1.5 or 2.5 mm thick, ensuring air tightness and no squeaking.• Central gap plastic material 3 or 5 mm thick.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Gres of ceramic ~42-43 8-9 34 0.05 ~26 90 1 Antistatic >38 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative offices, reception halls , banks, workrooms without antistatic requirements.
Edgea
600
a
600
c
e
bCovering
Calcium sulphatecore
Central gap
Bottom surface
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
26
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG6AVH 60x60
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 5.00 5.20 5.70 6.20 5.20 21.00 25.00 31.00 35.00 25.00
Ultimate load kN(4) 8.5 9.5 11.0 11.8 9.5EN 12825 3A2 4A2 5A2 5A2 4A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
• Core made of high density calcium sulphate and organic fibres, 30 mm thick.• Galvanized steel tray lower surface 0.4 mm thick.• Gres of ceramic top surface covering 8-11 mm thick, 60x60 cm.• Grey PVC edge trim 1.5 or 2.5 mm thick, ensuring air tightness and no squeaking.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Gres of ceramic ~38.5-41.5 8-11 30 ~0.4 ~25 45 1 Antistatic >34 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
Calcium sulphatecore
Edge
Coveringb
c
e
a
a60
0
600
Bottom surface
covering: ceramiccore: inert Material
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
27
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG6AVH 30x30
covering: ceramiccore: inert Material
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 4.00 4.50 5.20 5.60 4.50 20.00 25.00 30.00 25.00 25.00
Ultimate load kN(4) 8.0 9.0 10.2 11.0 9.0EN 12825 3A2 4A2 5A2 5A2 4A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
• Core made of high density calcium sulphate and organic fibres, 30 mm thick. • Galvanized steel tray lower surface 0.4 mm thick.• Gres of ceramic top surface covering 8-11 mm thick, 30 x 30 cm. • Grey PVC edge trim 1.5 or 2.5 mm thick, ensuring air tightness and no squeaking.• Central gap plastic material 5 mm thick.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Gres of ceramic ~38.4-41.4 8-11 30 ~0.4 ~25 45 1 Antistatic >34 0.41/3.200
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
600
600
a
a Edge
e
c
b
Bottom surface
Central gap
Covering
Calcium sulphate core
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
28
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG3AVH 60x60• Core made of high density calcium sulphate and organic fibres, 34 mm thick.• Galvanized steel tray lower surface 0.4 mm thick.• Gres of ceramic top surface covering 8-11 mm thick, 60x60 cm.• Grey PVC edge trim 1.5 or 2.5 mm thick, ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 5.80 6.10 6.60 7.10 6.10 33.00 37.00 41.00 46.00 37.00
Ultimate load kN(4) 10.5 11.2 12.8 14.2 11.2EN 12825 5A2 5A2 6A2 6A2 5A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Gres of ceramic ~42.5-45.5 8-11 34 ~0.4 ~27 60 1 >1011 >38 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
Bottom surface
Calcium sulphatecore
Edge
Coveringb
c
e
a
a60
0
600
covering: ceramiccore: inert Material
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
29
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG3AVH 30x30
covering: ceramiccore: inert Material
• Core made of high density calcium sulphate and organic fibres, 34 mm thick.• Galvanized steel tray lower surface 0.4 mm thick.• Gres of ceramic top surface covering 8-9 mm, thick, 30x30 cm.• Grey PVC edge trim 2.5 mm thick, ensuring air tightness and no squeaking.• Central gap plastic material 5 mm thick.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 5.00 5.50 6.00 6.50 5.50 33.00 37.00 41.00 46.00 37.00
Ultimate load kN(4) 9.8 10.5 12.1 13.2 10,5EN 12825 4A2 5A2 6A2 6A2 5A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Gres of ceramic ~42.4-45.4 8-9 34 ~0.4 ~27 60 1 >1011 >38 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
600
600
a
a
e
c
b
Calcium solphatecore
Bottom surface
Central gap
Covering
Edge
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
30
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG1AVZ
covering: Natural Stonecore: inert Material
• High density calcium sulphate core 12.5 mm thick.• Galvanized steel tray lower surface approx. 0.4 mm thick.• Natural stone (marble, granite) covering material 17÷18 mm thick, 60x60 cm as single slab.• Grey plastic semirigid edge trim 0.8 mm thick, ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.20 2.50 3.50 4.50 2.50 16.00 18.00 22.00 27.00 18.00
Ultimate load kN(4) 10.8 11.3 12.3 12.8 11.3EN 12825 4A2 5A2 6A2 6A2 5A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Natural stone ~30-31 17-18 12.5 ~0.4 ~27 45 1 Antistatic - 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representatives office, reception halls, banks.
a
a
600
600
Edge
Bottom surface
e
Covering
Calcium sulphatecore
b
c
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
31
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG2AVZ
covering: Natural Stonecore: inert Material
• High density calcium sulphate core 22 mm thick.• Galvanized steel tray lower surface approx. 0.4 mm thick.• Natural stone (marble, granite) covering material 20 mm thick.• Grey plastic semirigid edge trim 0.8 mm thick, ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.50 3.70 4.60 5.10 3.70 20.00 23.00 30.00 35.00 23.00
Ultimate load kN(4) 12.8 13.5 14.1 15.1 13.5EN 12825 5A2 6A2 6A2 6A2 6A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Natural stone ~39-40 17-18 22 ~0.4 ~32 45 1 Antistatic >34 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
Calcium sulphatecore
600
600
ca Edge
b Covering
eBottom surfacea
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
32
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG2AVQ
covering:Marble agglomeratecore: inert material
• High density calcium sulphate core 22 mm thick;• Galvanized steel tray lower surface approx. 0.4 mm thick;• Artificial marble agglomerate covering material 12-13 mm thick;• Grey plastic semirigid edge trim 0.8 mm thick, ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.50 3.70 4.60 5.10 3.70 20.00 23.00 30.00 35.00 23.00
Ultimate load kN(4) 12.8 13.5 14.1 15.1 13.5EN 12825 5A2 6A2 6A2 6A2 6A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass ohm dB W/m °C
Marble agglomerate ~34-35 12-13 22 ~0.4 ~32 45 1 >1011 >34 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
Calcium sulphatecore
600
600
ca Edge
b Covering
eBottom surfacea
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
33
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
covering:Marble agglomeratecore: inert material
Panel
PLTMMW
covering: Parquetcore: chipboard
• Core made of high density chipboard and thermosetting resins 38 mm thick;• Aluminium foil lower surface 0.05 mm thick;• Wooden parquet covering approx. 4 mm thick, composed of n° 8 or 9 strips, approx. 67 or 75 mm wide.• Beige plastic semirigid edge trim 0.45 mm thick ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.00 2.60 3.60 4.20 2.60 13.00 17.00 23.00 27.00 17.00
Ultimate load kN(4) 5.1 5.4 6.4 6.8 5.4EN 12825 1A2 1A2 2A2 2A2 1A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Parquet ~42 ~4 38 0.05 ~11 45 1 Antistatic >32 0.17
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative offices.
a
600
600
Chipboard coreca
Edge
b Covering
eBottom surface
n° 8 or 9 strips
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
34
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PLTMVW
covering: Parquetcore: chipboard
• Core made of high density chipboard and thermosetting resins 38 mm thick;• Galvanized steel tray lower surface approx. 0.4 mm thick.• Wooden parquet covering approx. 4 mm thick, composed of n° 8 or 9 strips, approx. 67 or 75 mm wide.• Beige plastic semirigid edge trim 0.45 mm thick ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.00 3.50 4.50 5.00 3.50 21.00 23.00 31.00 35.00 23.00
Ultimate load kN(4) 6.5 6.9 7.8 8.2 6.9EN 12825 2A2 2A2 2A2 3A2 2A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Parquet ~43.5 5 38 0.4 ~12 30 - >1011 >32 0.17
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative offices.
a
600
600
Chipboard coreca Edge
b Covering
eBottom surface
n° 8 or 9 strips
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
35
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG2AVH 60x60
covering: ceramiccore: calcium sulphate
• Core made of high density calcium sulphate and organic fibres, 22 mm thick;• Galvanized steel tray lower surface 0.4 mm thick;• Gres of ceramic top surface covering 8-11 mm thick, 60x60 cm;• Grey PVC edge trim 1.5 or 2.5 mm thick, ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.10 3.30 4.60 5.10 3.30 20.00 23.00 30.00 35.00 23.00
Ultimate load kN(4) 5.0 6.0 6.7 7.5 6.0EN 12825 1A2 2A2 2A2 2A2 2A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Gres of ceramic ~31-34 8-11 22 0.4 ~19 45 1 >1011 >30 0.26
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
Bottom surface
Calcium sulphatecore
Edge
Coveringb
c
e
a
a60
0
600
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
36
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG2AVH 30x30
covering: ceramiccore: calcium sulphate
• Core made of high density calcium sulphate, 22 mm thick;• Galvanized steel tray lower surface 0.4 mm thick;• Gres of ceramic top surface covering 8-9 mm thick, 30x30 cm;• Grey PVC edge trim 2.5 mm thick, ensuring air tightness and no squeaking.• Central gap plastic material 5 mm thick.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.10 2.70 3.60 4.10 2.70 20.00 23.00 30.00 35.00 23.00
Ultimate load kN(4) 4.5 5.2 5.7 6.3 5.2EN 12825 1A2 1A2 1A2 2A2 1A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Gres of ceramic ~31-34 8-9 22 0.4 ~19/21 45 1 >1011 >30 0.26/3.200
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative Offices, reception halls, banks, workrooms without antistatic requirements.
600
600
a
a
e
c
Central gap
Coveringb
Calcium sulphatecore
Bottom surface
Edge
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
37
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG6AMW
covering: Parquetcore: inert Material
• Core made of high density calcium sulphate and organic fibres, 30 mm thick.• Aluminium foil lower surface 0.05 mm thick.• Wooden parquet covering approx. 4 mm thick, composed of n° 8 or 9 strips, approx. 67 or 75 mm wide.• Beige plastic semirigid edge trim 0.6 mm thick, ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.40 3.10 3.80 4.80 3.10 18.00 22.00 28.00 32.00 22.00
Ultimate load kN(4) 6.6 7.1 7.9 8.3 7.1EN 12825 2A2 2A2 2A2 3A2 2A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Parquet ~34 ~4 30 0.05 ~18 60 - Antistatic >34 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative offices.
a
600
600
Calcium sulphatecore
ca Edge
b Covering
eBottom surface
n° 8 or 9 sprips
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
Calcium sulphatecore
cEdge
b Covering
eBottom surface
a
a
600
600
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
38
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG6AVW
covering: Parquetcore: inert Material
• Core made of high density calcium sulphate and organic fibres, 30 mm thick.• Galvanized steel tray lower surface 0.4 mm thick;• Wooden parquet covering approx. 4 mm thick, composed of n° 8 or 9 strips, approx. 67 or 75 mm wide.• Beige plastic semirigid edge trim 0.6 mm thick, ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 4.00 4.50 5.40 5.80 4.50 20.00 25.00 30.00 35.00 25.00
Ultimate load kN(4) 8.0 9.0 10.2 11.0 9.0EN 12825 3A2 4A2 5A2 5A2 4A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Parquet ~34.5 ~4 30 0.4 ~19 45 1 Antistatic >34 0.41/0.17
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative office with medium-heavyload bearing requirements
a
600
600
Calcium sulphatecore
ca Edge
b Covering
eBottom surface
n° 8 or 9 sprips
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
39
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG3AMW• Core made of high density calcium sulphate and organic fibres, 34 mm thick.• Aluminium foil lower surface 0.05 mm thick.• Wooden parquet covering approx. 4 mm thick, composed of n° 8 or 9 strips, approx. 67 or 75 mm wide.• Beige plastic semirigid edge trim 0.6 mm thick, ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.0 3.5 4.5 5.0 3.5 23.00 25.00 31.00 35.00 25.00
Ultimate load kN(4) 8.1 8.6 9.7 10.1 8.6EN 12825 2A2 3A2 4A2 5A2 3A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass - dB W/m °C
Parquet ~38 ~4 34 0.05 ~20 90 1 Antistatic >38 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative offices.
a
600
600
Calcium sulphatecore
ca Edge
b Covering
eBottom surface
n° 8 or 9 strips
covering: Parquetcore: inert Material
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
40
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG3AVW
covering: Parquetcore: inert Material
• Core made of high density calcium sulphate and organic fibres, 34 mm thick.• Galvanized steel tray lower surface 0.4 mm thick.• Wooden parquet covering approx. 4 mm thick, composed of n° 8 or 9 strips, approx. 67 or 75 mm wide.• PVC edge trim 0,6 mm thick, ensuring air tightness and no squeaking, beige colour.
Specifica
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 5.00 5.50 6.00 6.50 5.50 29.00 34.00 39.00 45.00 34.00
Ultimate load kN(4) 9.8 10.5 12.0 13.0 10.5EN 12825 4A2 5A2 6A2 6A2 5A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Parquet ~39.5 5 34 0.5 ~21 60 - >1011 >38 0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative offices.
a
600
600
Calcium sulphatecore
ca Edge
b Covering
eBottom surface
n° 8 or 9 strips
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
41
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PW4AMW• Core made of high density chipboard and thermosetting resins, 28 mm thick matched to a
high density calcium sulphate and organic fibres board 12.5 mm thick.• Aluminium foil lower surface 0.05 mm thick.• Wooden parquet covering approx. 4 mm thick, composed of n° 8 or 9 strips, approx. 67 or 75 mm wide.• PVC edge trim, 0.45 mm thick, ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.30 2.70 3.20 4.00 2.70 16.00 19.00 25.00 30.00 19.00
Ultimate load kN(4) 5.2 5.8 6.7 8.0 5.8EN 12825 1A2 1A2 2A2 3A2 1A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
ToP SURfAcE
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
a b c d e kg REI CSE/RFclass - dB W/m °C
Parquet ~44.5 4 28 12.5 0.05 ~15 60 1 Antistatic >34 0.17/0.41
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative offices, with medium load bearing requirements and any room with high fire resistance rate.
covering: Parquetcore: chipboard+inert Material
Calcium sulphate
Covering
c
d
Bottom surface
Chipboard core
Edgea
e
b
core
a
600
600
n° 8 or 9 strips
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
42
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panels
PBAT-PBAO
core: Glass
• Core made of three glass layers, bound by PVC film, 26 mm thick;• PVC edge trim, approx. 1 mm thick, ensuring air tightness and no squeaking.
600
a60
0 a Edgeb
Glass core
coVERiNG
Nominal dimension(mm)
Weight each
fire resistance
fire reaction
Electrical resistance
Acoustic insulation
conductivity λ (core/cover)
Thick Side kg REI CSE/RFclass Ω dB W/m °C
Trasparent/opaque ~26 600 ~22 0 0 - - -
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.00 2.60 3.60 4.20 2.60 13.00 17.00 23.00 27.00 17.00
Ultimate load kN(4) 4.0 4.5 5.5 6.1 4.5EN 12825 1A2 1A2 1A2 2A2 1A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Representative offices, reception halls , banks, rooms with particular architectural requirements.
Legend standard EN 12825 Prospectus 1
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
43
44
45
Metal Line
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
46
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PLNAR0
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.30 3.60 4.00 4.50 3.60 17.50 23.00 25.00 29.50 23.00
Ultimate load kN(4) 5.0 6.5 8.2 9.0 6.5EN 12825 1A2 2A2 3A2 4A2 2A2
• Core made of high density chipboard and thermosetting resins, 28 mm thick;• Galvanized steel tray lower surface 0.4 mm thick;• Top surface galvanized steel 0.4 mm thick;• PVC edge trim, approx. 0.5 mm thick, ensuring air tightness and no squeaking.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: Galvanized Steelcore: chipboard
FIELDS OF APPLICATION: Offices, EDPs, control rooms, laboratories, with medium-high load bearing requirements.
APPLICATION NOTES:Suitable for loose-lay covering material.
Edge Chipboard core
Covering
e
c
b
a
Bottom surface
600
a
600
ToP SURfAcE
Nominal dimension (mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Galvanized steel ~29 0.4 28 0.4 ~10 15 1 ≤2x1010 30 0.17
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
47
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PLTMR0
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.80 4.60 5.00 6.00 4.60 24.00 26.00 34.00 39.00 26.00
Ultimate load kN(4) 6.8 7.5 8.4 9.3 7.5EN 12825 2A2 2A2 3A2 4A2 2A2
• Core made of high density chipboard and thermosetting resins, 38 mm thick.• Galvanized steel tray lower surface 0.4 mm thick.• Top surface galvanized steel 0.4 mm thick.• PVC edge trim, approx. 0.5 mm thick, ensuring air tightness and no squeaking.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
covering: Galvanized Steelcore: chipboard
FIELDS OF APPLICATION: Offices, EDPs, control rooms, laboratories, with high load bearing requirements.
APPLICATION NOTES:Suitable for loose lay covering material.
EdgeChipboard core
Covering
e
c
b
a
Bottom surface
600
a
600
ToP SURfAcE
Nominal dimension (mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Galvanized steel ~39 0.4 38 0.4 ~12.5 30 1 ≤2x1010 30 0.17
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
48
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
P30SS/W
covering: Variouscore: Steel
• Perforated galvanised steel panel with 576 holes diam. 10.5 mm.• Core made of galvanised perforated steel sheet 2.5 mm thick, sustained by 6 internal omega
profiles 2.5 mm thick.• It is available with airflow regulation device (P30SW), made of 2 perforated galvanised steel
foils 0.8 mm thick Black plastic semirigid edge trim, approx. 0.5 mm thick, ensuring air tightness and no squeaking.
• The metallic core is 28 mm thick. It is possible to obtain different thickness using adjustment pedestals, delivered separately.
ToP SURfAcENominal dimensions
(mm)Weight each Electrical resistance(1)
a b c e kg omhVarious 29-30 1-2 28 0-1.6 ~11-12 ≤2x1010
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.00 2.60 3.60 4.20 2.60 13.00 17.00 23.00 27.00 17.00
Ultimate load kN(4) 6.1 6.8 8.2 9.1 6.5EN 12825 1A2 2A2 3A2 4A2 2A2
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
classe 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Light-medium load requirement cleanrooms, offices, EDP, control rooms, laboratories.
APPLICATION NOTES:Suitable for application of homogeneous vinyl, rubber, plastic laminate, needle-punch carpet.Possibility to lay it directly on the slab, sustained just by the adjustment pedestals (max. height 100 mm)
c
b Covering
Core
Edge
Air flow adjustmente
Pedestal
a
600
a
600
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
49
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PLTMMF
covering: decorated steelcore: chipboard
• Core made of high density chipboard and thermosetting resins, 38 mm thick.• Aluminium foil lower surface 0.05 mm thick.• Top covering of decorated steel plate 0.8 mm thick.• PVC edge trim, approx. 0.5 mm thick, ensuring air tightness and no squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 2.20 2.80 3.80 4.40 2.80 24.00 26.00 34.00 39.00 26.00
Ultimate load kN(4) 6.8 7.3 8.2 8.4 7.3EN 12825 2A2 2A2 3A2 3A2 2A2
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: High tech offices.
ToP SURfAcE
Nominal dimension (mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
decorated steel ~39 0.8 38 0.05 ~11.5 45 1 ≤2x1010 32 0.17
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
EdgeChipboard core
Covering
e
c
b
a
Bottom surface
600
600
a
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
50
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG3ARO
covering: Galvanized Steelcore: calcium sulphate
• Core made of high density calcium sulphate and organic fibres, 34 mm thick.• Galvanized steel tray approx. 0,4 mm on lower surface and galvanized steel sheet
approx. 0,4 mm on top surface.• Black plastic semirigid edge trim 0,6 mm thick, ensuring air tightness and no
squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 5.00 5.50 6.00 6.50 5.50 29.00 34.00 39.00 45.00 34.00
Ultimate load kN(4) 9.8 10.5 12.0 13.0 10.5EN 12825 4A2 5A2 6A2 6A2 5A2
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION:Offices, EDPs, control rooms, laboratories, with high load bearing requirements.
ToP SURfAcE
Nominal dimension (mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Steel sheet ~35 0.4 34 0.4 ~20 60 1 ≤2x1010 >38 0.41
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
EdgeCalcium sulphatecore
Covering
e
c
b
a
Bottom surface
600
a
600
APPLICATION NOTES:Suitable for loose lay covering material.
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
TECHNICAL DATA
MECHANICAL CHARACTERISTICS (Deflection ≤2.5 mm; Safety Factor ≥2)
51
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
Panel
PG6ARO
covering: Steelcore: inert Material
• Core made of high density calcium sulphate and organic fibres, 30 mm thick.• Galvanized steel tray lower side 0.4 mm thick.• Galvanized steel sheet on top surface 0.4 mm thick.• Black plastic semirigid material edge trim 0,6 mm thick, ensuring air tightness and no
squeaking.
Specification
STRUcTURE
coNcENTRATEd LoAd kN(2) diSTRiBUTEd LoAd kN/m2 (3)
MPS/L MPM MPH MPO/MPC SSH MPS/L MPM MPH MPO/MPC SSHWorking load(5) 3.80 4.60 5.00 6.00 4.60 20.00 25.00 30.00 35.00 25.00
Ultimate load kN(4) 8.0 9.0 10.2 11.0 9.0EN 12825 3A2 4A2 5A2 5A2 4A2
dEfLEcTioN cLASS SAfETy fAcToR
A=2.5 mm 2
B=3.0 mm 3
C=3.5 mm 4
class 1 2 3 4 5 6
Ultimate load kN ≥ 4 ≥ 6 ≥ 8 ≥ 9 ≥ 10 ≥ 12
FIELDS OF APPLICATION: Offices, EDPs, control rooms, technical rooms, laboratories, with medium load bearing requirements.
ToP SURfAcE
Nominal dimension (mm)
Weight each
fire resistance
fire reaction
Electrical resistance(1)
Acoustic insulation
conductivity λ (core/cover)
a b c e kg REI CSE/RFclass Ω dB W/m °C
Steel sheet ~31 ~0.4 30 ~0.4 ~17.5 60 1 ≤2x1010 34 0.41
(2) Load valid at any point of the system.(3) Not provided by EN 12825.(4) Ultimate load at the failure moment (tensile strenght).(5) When the applied load is equivalent to to the working load the measured deflection must not exceed the value declared in accordance with the prospectus.
APPLICATION NOTES:Suitable for loose lay covering material (carpet)
Legend standard EN 12825 Prospectus 1
(1) Value for panel with antistatic coverings. For conductive coverings consider 1.5x105 ÷ 1x107. For other coverings please ask Nesite staff.
For Finished Floor Height FFH higher than 750 mm, please verify the real operating condition of the System.
Edge Calcium sulphatecore
Covering
e
c
b
a
Bottom surface
600
a
600
52
53
Substructure
Transpack Group Service S.p.A. reserves the right to change technical data without notice
54
Rev. July 2010
Subtructure
MPS
FIELD OF APPLICATION: Offices, EDPs, control rooms, laboratories and any other industrial application with light/medium load requirements.
APPLICATION NOTES:- A regular subfloor is necessary;- The base must be glued to the subfloor (with poliuretanic and conductive one component glue);
- The height adjustment nut must be locked by using a few drops of thread locking glue.
Pedestal low configuration
BASE: 2 mm thick galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a diameter 14 mm galvanized steel threaded rod (type M14).
COLUMN: 3 mm thick galvanized steel head, diameter 90 mm, with 4 series of notches, coupled with a 25 mm galvanized steel tube 1.5 mm thick, with a M14 internally threaded galvanized steel rod which fits into the pedestal base’s rod.
HEIGHT ADJUSTMENT: obtained by screwing/unscrewing the base’s threaded rod into the column. Locking is obtained by use of a thread locking glue (one component adhesive).
NOTE: the above mentioned components are supplied already assembled (thread locking glue excluded).
Pedestal high configuration
BASE: 2 mm thick galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a diameter 14 mm galvanized steel threaded rod (type M14).
COLUMN: 3 mm thick galvanized steel head, diameter 90 mm, with 4 series of notches, coupled with a 25 mm galvanized steel tube 1.5 mm thick, tapered on one end to fit into the pedestal base’s rod.
HEIGHT ADJUSTMENT: obtained by a galvanized steel nut provided with 6 male notches for self-locking with the female notches on the column.
NOTE: the above mentioned components are supplied in two separate packings, assembled as follows: - Base + adjusting nut; - Column (head + tube).
Components valid for both low and high configuration
HEAD GASKET: 3 mm thick black conductive polyethylene with electrical resistance 104 ohms.It self-locates onto the head owing to 4 small protuberances that fit into suitable notches on the head.
DESCRIPTION
MPS structure is available in two basic configurations:
1 - With nominal height 30, 40, 60, 70 e 90 mm (low configuration);
2 - With nominal height from 110 up to 600 mm (high configuration).
Without stringers
Transpack Group Service S.p.A. reserves the right to change technical data without notice
55
Rev. July 2010
Subtructure
MPS
diGiT AdJUSTMENT coNfiGURATioN
03 Min 32.5mm Max 45mm Low
04 Min 37mm Max 50mm Low
06 Min 50mm Max 80mm Low
07 Min 65mm Max 90mm Low
09 Min 75mm Max 115mm Low
11 Min 100mm Max 120mm High
12 Min110mm Max 130mm High
13 Min 110mm Max 150mm High
According to height cm - 20mm + 20mm High
2 Kg / m2 H = 200 mm Extra weight for every further cm of height: 0.028 Kg/cm
LOW HIGH
H mm 45 65 80 95 105 120 200 300 400 500 600
Kn(1) 40.00 40.00 40.00 40.00 40.00 39.00 38.50 37.00 36.00 34.50 33.00
DESCRIPTION RIF. MATERIAL PIECES m2
Base 1 Galvanized steel 3.3Nut M 14 2 Galvanized steel 3.3Column Ø 25 3 Galvanized steel 3.3Head 4 Galvanized steel 3.3Head gasket 5 Conductive polyethylene 3.3Internally threaded rodM 14 6 Galvanized steel 3.3
TECHNICAL DATA
TOTAL WEIGHT
PEDESTAL AXIAL LOAD EN 12825
PEDESTAL AXIAL LOAD EN 12825
MPS low MPS low: exploded MPS high: explodedMPS high
1
1
2
6
3
54
4
3
5
Without stringers
Transpack Group Service S.p.A. reserves the right to change technical data without notice
56
Rev. July 2010
Subtructure
MPL
FIELD OF APPLICATION: Offices, EDPs, control rooms, laboratories and any other industrial application with light/medium load requirements.
APPLICATION NOTES:- A regular subfloor is necessary;- For over 600mm height, base glueing is recommended (one component conductive poliurethane adhesive);
- Earthing by means of connections every 30 m2.
Pedestal low configuration
BASE: 2 mm thick galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a diameter 14 mm galvanized steel threaded rod (type M14).
COLUMN: 3 mm thick galvanized steel head, diameter 90 mm, with 4 series of notches, coupled with a 25 mm galvanized steel tube 1.5 mm thick, with a M14 internally threaded galvanized steel rod which fits into the pedestal base’s rod.
HEIGHT ADJUSTMENT: obtained by screwing/unscrewing the base’s threaded rod into the column. Locking is obtained by use of a thread locking glue (one component adhesive).
NOTE: the above mentioned components are supplied already assembled (thread locking glue excluded).
Pedestal high configuration
BASE: 2 mm thick galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a diameter 14 mm galvanized steel threaded rod (type M14).
COLUMN: 3 mm thick galvanized steel head, diameter 90 mm, with 4 series of notches, coupled with a 25 mm galvanized steel tube 1.5 mm thick, tapered on one end to fit into the pedestal base’s rod.
HEIGHT ADJUSTMENT: obtained by a galvanized steel nut provided with 6 male notches for self-locking with the female notches on the column.
NOTE: the above mentioned components are supplied in two separate packings, assembled as follows: − Base + adjusting nut; − Column (head + tube).
Components valid for both low and high configuration
STRINGER: galvanized steel open U section 15 x 25 x 1 mm.
STRINGER GASKET: 1 mm thick black self-extinguishing extruded polyethylene C shaped.
HEAD GASKET: 3 mm thick black conductive polyethylene with electrical resistance 104 ohms.It self-locates onto the head owing to 4 small protuberances which fit into suitable notches on the head.
FIXING SCREW: self-tapping galvanized steel M5.
DESCRIPTION
MPL structure is available in two basic configurations:
1 - With nominal height 30, 40, 60, 70 e 90 mm (low configuration);
2 - With nominal height from 110 up to 600 mm (high configuration).
open U section stringer
Transpack Group Service S.p.A. reserves the right to change technical data without notice
57
Rev. July 2010
Subtructure
MPL
diGiT AdJUSTMENT coNfiGURATioN
03 Min 32.5mm Max 45mm Low
04 Min 37mm Max 50mm Low
06 Min 50mm Max 80mm Low
07 Min 65mm Max 90mm Low
09 Min 75mm Max 115mm Low
11 Min 100mm Max 120mm High
12 Min110mm Max 130mm High
13 Min 110mm Max 150mm High
According to height cm - 20mm + 20mm High
4.2 Kg / m2 H = 200 mm Extra weight for every further cm of height: 0.028 Kg / cm
LOW HIGH
H mm 45 65 80 95 105 120 200 300 400 500 600 700 800 900
Kn(1) 40.00 40.00 40.00 40.00 40.00 39.00 38.50 37.00 36.00 34.50 33.00 31.50 30.00 28.00
DESCRIPTION RIF. MATERIAL PIECES m2
Base 1 Galvanized steel 3.3Nut M 14 2 Galvanized steel 3.3Column Ø 25 3 Galvanized steel 3.3Head 4 Galvanized steel 3.3Head gasket 5 Conductive polyethylene 3.3Internally threaded rod M 14 6 Galvanized steel 3.3Stringer 7 Galvanized steel 5.7Stringer gasket 8 Self-extinguishing polyethylene 5.7Fixing screw M5 9 Galvanized steel 12
TECHNICAL DATA
TOTAL WEIGHT
PEDESTAL AXIAL LOAD EN 12825
PEDESTAL AXIAL LOAD EN 12825
MPL low MPL low: exploded MPL high: explodedMPL high
1
1
2
6
3
54
4
3
5
7
9 8
7
89
(1) The substructure must sustain the working load 4 times.
open U section stringer
Transpack Group Service S.p.A. reserves the right to change technical data without notice
58
Rev. July 2010
Subtructure
MPM
FIELD OF APPLICATION:Offices, EDPs, control rooms, laboratories and any other industrial application with medium load requirements..
APPLICATION NOTES:- A regular subfloor is necessary;- For over 600mm height, base glueing is recommended (one component conductive poliurethane adhesive);
- Earthing by means of connections every 30 m2.
Pedestal low configuration
BASE: 2 mm thick galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a diameter 14 mm galvanized steel threaded rod (type M14).
COLUMN: 3 mm thick galvanized steel head, diameter 90 mm, with 4 series of notches, coupled with a 25 mm galvanized steel tube 1.5 mm thick, with a M14 internally threaded galvanized steel rod which fits into the pedestal base’s rod.
HEIGHT ADJUSTMENT: obtained by screwing/unscrewing the base’s threaded rod into the column. Locking is obtained by use of a thread locking glue (one component adhesive).
NOTE: the above mentioned components are supplied already assembled (thread locking glue excluded).
Pedestal high configuration
BASE: 2 mm thick galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a diameter 14 mm galvanized steel threaded rod (type M14).
COLUMN: 3 mm thick galvanized steel head, diameter 90 mm, with 4 series of notches, coupled with a 25 mm galvanized steel tube 1.5 mm thick, tapered on one end to fit into the pedestal base’s rod.
HEIGHT ADJUSTMENT: obtained by a galvanized steel nut provided with 6 male notches for self-locking with the female notches on the column.
NOTA: the above mentioned components are supplied in two separate packings, assembled as follows: − Base + adjusting nut; − Column (head + tube).
Components valid for both low and high configuration
STRINGER: galvanized steel open U section 30 x 25 x 1 mm.
STRINGER GASKET: 1 mm thick black self-extinguishing extruded polyethylene C shaped.
HEAD GASKET: 3 mm thick black conductive polyethylene with electrical resistance 104 ohms. It self-locates onto the head owing to 4 small protuberances which fit into suitable notches on the head.
FIXING SCREW: self-tapping galvanized steel M5.
DESCRIPTION
MPM structure is available in two basic configurations:
1 - With nominal height 60, 70 e 90 mm (low configuration);
2 - With nominal height from 110 up to 900 mm (high configuration).
open U section stringer
Transpack Group Service S.p.A. reserves the right to change technical data without notice
59
Rev. July 2010
Subtructure
MPM
diGiT AdJUSTMENT coNfiGURATioN
06 Min 50mm Max 80mm Low
07 Min 65mm Max 90mm Low
09 Min 75mm Max 115mm Low
11 Min 100mm Max 120mm High
12 Min110mm Max 130mm High
13 Min 110mm Max 150mm High
According to height cm - 20mm + 20mm High
4.5 Kg / m2 H = 200 mm Extra weight for every further cm of height:0.028 Kg / cm
LOW HIGH
H mm 45 65 80 95 105 120 200 300 400 500 600 700 800 900
Kn(1) 40.00 40.00 40.00 40.00 40.00 39.00 38.50 37.00 36.00 34.50 33.00 31.50 30.00 28.00
DESCRIPTION RIF. MATERIAL PIECES m2
Base 1 Galvanized steel 3.3Nut M 14 2 Galvanized steel 3.3Column Ø 25 3 Galvanized steel 3.3Head 4 Galvanized steel 3.3Head gasket 5 Conductive polyethylene 3.3Internally threaded rod M 14 6 Galvanized steel 3.3Stringer 7 Galvanized steel 5.7Stringer gasket 8 Self-extinguishing polyethylene 5.7Fixing screw M5 9 Galvanized steel 12
TECHNICAL DATA
TOTAL WEIGHT
PEDESTAL AXIAL LOAD EN 12825
PEDESTAL AXIAL LOAD EN 12825
MPM low MPM low: exploded MPM high: explodedMPM high
1
1
2
6
3
54
4
3
5
7
9 8
7
89
(1) The substructure must sustain the working load 4 times.
open U section stringer
Transpack Group Service S.p.A. reserves the right to change technical data without notice
60
Rev. July 2010
Subtructure
MPH
FIELD OF APPLICATION: Offices, EDPs, control rooms, laboratories and any other industrial application with medium/heavy load requirements.
APPLICATION NOTES:- A regular subfloor is necessary;- For over 600mm height, base glueing is recommended (one component conductive poliurethane adhesive);
- Earthing by means of connections every 30 m2.
Pedestal low configuration
BASE: 2 mm thick galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a diameter 14 mm galvanized steel threaded rod (type M14).
COLUMN: 3 mm thick galvanized steel head, diameter 90 mm, with 4 series of notches, coupled with a 25 mm galvanized steel tube 1.5 mm thick, with a M14 internally threaded galvanized steel rod which fits into the pedestal base’s rod.
HEIGHT ADJUSTMENT: obtained by screwing/unscrewing the base’s threaded rod into the column. Locking is obtained by use of a thread locking glue (one component adhesive).
NOTE: the above mentioned components are supplied already assembled (thread locking glue excluded).
Pedestal high configuration
BASE: 2 mm thick galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a diameter 14 mm galvanized steel threaded rod (type M14).
COLUMN: 3 mm thick galvanized steel head, diameter 90 mm, with 4 series of notches, coupled with a 25 mm galvanized steel tube 1.5 mm thick, tapered on one end to fit into the pedestal base’s rod.
HEIGHT ADJUSTMENT: obtained by a galvanized steel nut provided with 6 male notches for self-locking with the female notches on the column.
NOTE: the above mentioned components are supplied in two separate packings, assembled as follows: − Base + adjusting nut; − Column (head + tube).
Components valid for both low and high configuration
STRINGER: galvanized steel closed rectangular section tube, 40 x 25 x 1.2 mm.
STRINGER GASKET: 1 mm thick black self-extinguishing extruded polyethylene C shaped.
HEAD GASKET: 3 mm thick black conductive polyethylene with electrical resistance 104 ohms. It self-locates onto the head owing to 4 small protuberances which fit into suitable notches on the head.
FIXING SCREW: self-tapping galvanized steel M5.
DESCRIPTION
MPH structure is available in two basic configurations:
1 - With nominal height 60, 70 and 90 mm (low configuration);
2 - With nominal height from 110 up to mm (high configuration).
closed section stringer
Transpack Group Service S.p.A. reserves the right to change technical data without notice
61
Rev. July 2010
Subtructure
MPH
diGiT AdJUSTMENT coNfiGURATioN
06 Min 50mm Max 80mm Low
07 Min 65mm Max 90mm Low
09 Min 75mm Max 115mm Low
11 Min 100mm Max 120mm High
12 Min110mm Max 130mm High
13 Min 110mm Max 150mm High
According to height cm - 20mm + 20mm High
6 Kg / m2 H = 200 mm Extra weight for every further cm of height: 0.028 Kg / cm
LOW HIGH
H mm 65 80 95 105 120 200 300 400 500 600 700 800 900
Kn(1) 40.00 40.00 40.00 40.00 39.00 38.50 37.00 36.00 34.50 33.00 31.50 30.00 28.00
DESCRIPTION RIF. MATERIAL PIECES m2
Base 1 Galvanized steel 3.3Nut M 14 2 Galvanized steel 3.3Column Ø 25 3 Galvanized steel 3.3Head 4 Galvanized steel 3.3Head gasket 5 Conductive polyethylene 3.3Internally threaded rod M 14 6 Galvanized steel 3.3Stringer 7 Galvanized steel 5.7Stringer gasket 8 Self-extinguishing polyethylene 5.7Fixing screw M5 9 Galvanized steel 12
TECHNICAL DATA
TOTAL WEIGHT
PEDESTAL AXIAL LOAD EN 12825
PEDESTAL AXIAL LOAD EN 12825
MPH low MPH low: exploded MPH high: explodedMPH high
1
1
2
6
3
54
4
3
5
7
9 8
7
89
(1) The substructure must sustain the working load 4 times.
closed section stringer
Transpack Group Service S.p.A. reserves the right to change technical data without notice
62
Rev. July 2010
Subtructure
MPC
FIELD OF APPLICATION: Offices, EDPs, control rooms, laboratories and any other industrial application with heavy load requirements.
APPLICATION NOTES:- A regular subfloor is necessary;- For over 600mm height, base glueing is recommended (one component conductive poliurethane adhesive);
- Earthing by means of connections every 30 m2.
Pedestal low configuration
BASE: 2 mm thick galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a diameter 14 mm galvanized steel threaded rod (type M14).
COLUMN: 3 mm thick galvanized steel head, diameter 90 mm, with 4 series of notches, coupled with a 25 mm galvanized steel tube 1.5 mm thick, with a M14 internally threaded galvanized steel rod which fits into the pedestal base’s rod.
HEIGHT ADJUSTMENT: obtained by screwing/unscrewing the base’s threaded rod into the column. Locking is obtained by use of a thread locking glue (one component adhesive).
NOTE: the above mentioned components are supplied already assembled (thread locking glue excluded).
Pedestal high configuration
BASE: 2 mm thick galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a diameter 14 mm galvanized steel threaded rod (type M14)..
COLUMN: 3 mm thick galvanized steel head, diameter 90 mm, with 4 series of notches, coupled with a 25 mm galvanized steel tube 1.5 mm thick, tapered on one end to fit into the pedestal base’s rod.
HEIGHT ADJUSTMENT: obtained by a galvanized steel nut provided with 6 male notches for self-locking with the female notches on the column.
NOTE: the above mentioned components are supplied in two separate packings, assembled as follows: - Base + adjusting nut; - Column (head + tube).
Components valid for both low and high configuration
STRINGER: galvanized steel omega closed section tube, height 33 mm, large 35 mm (40 mm on the base side), 1.2 mm thickness, supplied in two sizes: 560 e 1800 mm.
STRINGER GASKET: 1 mm thick black conductive extruded polyethylene C shaped.
GUARNIZIONE A CROCE: 2 mm thick black conductive extruded polyethylene C shaped, with electrical resistance 104 ohms.
HEAD GASKET: 3 mm thick black conductive polyethylene with electrical resistance 104 ohms.
FIXING SCREW: self-tapping galvanized steel M5.
FIXING PLATE: 1.5 mm thick galvanized steel plate.
DESCRIPTION
MPC structure is available in two basic configurations:
1 - With nominal height 75, 80, 100, e 125 mm (low configuration);
2 - With nominal height from 140 a 150, a 1025 mm (high configuration).
omega closed section stringer
Transpack Group Service S.p.A. reserves the right to change technical data without notice
63
Rev. July 2010
Subtructure
MPC
diGiT AdJUSTMENT coNfiGURATioN
08 Min 70mm Max 80mm Low
10 Min 85mm Max 115mm Low
13 Min 105mm Max 145mm Low
15 Min125mm Max 155mm Low
16 Min 135mm Max 165mm Low
According to height Up to 1025 +/- 25mm Standard
8.2 Kg / m2 H = 200 mm Extra weight for every further cm of height 0.028 Kg / cm
LOW HIGH
H mm 75 100 115 130 140 150 200 300 400 500 600 700 800 900
Kn(1) 40.00 40.00 40.00 40.00 40.00 39.00 38.50 37.00 36.00 34.50 33.00 31.50 30.00 28.00
DESCRIPTION RIF. MATERIAL PIECES m2
Base 1 Galvanized steel 3.3Nut M 14 2 Galvanized steel 3.3Column Ø 25 x 1.2mm 3 Galvanized steel 3.3Head 4 Galvanized steel 3.3Head gasket 5 Conductive polyethylene 3.5Stringer 560mm 6 Galvanized steel 3.5Stringer1800mm 7 Self-extinguishing polyethylene 1Stringer gasket L=560 8 Conductive polyethylene 3.5Stringer gasket L=1800 9 Galvanized steel 1Fixing screw M5 10 Galvanized steel 13.2Fixing plate 11 Galvanized steel 13.2Internally threaded rod M14 12 Galvanized steel 3.3
TECHNICAL DATA
TOTAL WEIGHT
PEDESTAL AXIAL LOAD EN 12825
PEDESTAL AXIAL LOAD EN 12825
(1) The substructure must sustain the working load 4 times.
omega closed section stringer
Transpack Group Service S.p.A. reserves the right to change technical data without notice
64
Rev. July 2010
Subtructure
SSH
FIELD OF APPLICATION: Offices, EDPs, control rooms, laboratories and any other industrial application with medium load requirements.
APPLICATION NOTES:- A regular subfloor is necessary;- For over 600mm height, base glueing is recommended (one component conductive poliurethane adhesive);
- Earthing by means of connections every 30 m2.
Configuration
Galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a 68 or 100 mm height M14 threaded rod complete of M14 adjustment nut, on which is laid a squared tube 25x25 mm of different height, tapered to fit into the threated rod. On top of the column the stringers are installed through Nesite joint method.
Components
BASE: Galvanized steel plate, diameter 90 mm, with 8 radial stiffening ribs, two of which are provided with a hole to fix a self-tapping screw (M5) in case of fastening to the slab. The base is coupled with a 68 or 100 mm height M14 threaded rod complete of M14 adjustment nut.
COLUMN: 25 x 25 mm galvanized steel squared tube, tapered to fit into the pedestal M14 base’s rod.
HEIGHT ADJUSTMENT: obtained by a galvanized steel nut provided with 6 male notches for self-locking with the female notches on the column.
FIXING PLATE: made of galvanized steel, specially shaped to be laid on top of the column and fix the stringers.
FIXING SCREW: self-tapping galvanized steel M5.
STRINGER: galvanized steel open U section 34 x 25 x 1.2 mm, specially shaped for fastening into the squared column.
STRINGER GASKET: 1.0 mm thick black self-extinguishing extruded polyethylene C shaped.
CROSS GASKET: 2.0 mm thick black conductive polyethylene with electrical resistance ≤104 ohms. It self- locates onto the cross of the stringers.
TERMINAL STRINGER: galvanized steel open U section 32.5 x 22-25 x 1.2 mm, specially shaped to be fastened onto the squared column and be inserted into a cut stringer. It is commonly used on the perimeter of the structure.
SPECIAL SUPPORT FOR GRILL: galvanized steel open U section, 28 x 14 mm, 1 mm thick, 100 mm long, meccanically fixed to the column.
DESCRIPTION
SSH structure is available with nominal height from 110 to 900 mm (high configuration).
open U section stringer
Transpack Group Service S.p.A. reserves the right to change technical data without notice
65
Rev. July 2010
Subtructure
SSH
diGiT AdJUSTMENT
11 Min 100mm Max 120mm
12 Min 110mm Max 130mm
13 Min 120mm Max 140mm
14 Min130mm Max 150mm
According to height - 10mm + 20mm
4.5 Kg / m2 H = 200 mm Extra weight for every further cm of height: 0.025 Kg / cm
H mm 105 115 125 135 150 200 300 400 500 600 700 800 900
Kn(1) 30.00 30.00 30.00 30.00 30.00 30.00 30.00 30.00 30.00 27.00 24.00 21.00 18.00
DESCRIPTION RIF. MATERIAL PIECES m2
Complete section 1Base M14 H=68mm (low) 2 Galvanized steel 3.3Base M14 H=100mm (standard) 3 Galvanized steel 3.3Column 25x25 4 Galvanized steel 3.3Fixing plate 5 Galvanized steel 3.3Fixing screw M5 6 Galvanized steel 3.3Stringer 7 Galvanized steel 5.7Stringer gasket 8 Conductive self-extinguishing 5.7Cross gasket 9 Conductive polyethylene 3.3Terminal stringer 10 Galvanized steel 1.5
TECHNICAL DATA
TOTAL WEIGHT
PEDESTAL AXIAL LOAD EN 12825
PEDESTAL AXIAL LOAD EN 12825
SSH: explodedSSH
1
2
4
,3
5
7
986
10
open U section stringer
Transpack Group Service S.p.A. reserves the right to change technical data without notice
66
Rev. July 2010
Subtructure
MP
Super High
diGiT HEiGHT (mm) AdJUSTMENT coNfiGURATioN
XX -- ± 25mm Standard
13.5 Kg / m2 H = 1000 mm Extra weight for every further cm of height: 0.054 Kg / cm
H mm 1000 1200 1400 1600 1800
Kn(1) 47.00 33.00 26.00 19.00 14.00
DESCRIPTON RIF. MATERIAL PIECES m2
Base 1 Galvanized steel 3.3Tube ø 35 approx. 2 Galvanized steel 3.3Internally threaded rod M18 key HEX 32 3 Galvanized steel 3.3Head with threaded rod M18 4 Galvanized steel 3.3Head gasket 5 Conductive polyethylene 3.3
TECHNICAL DATA
TOTAL WEIGHT
PEDESTAL AXIAL LOAD EN 12825
PEDESTAL AXIAL LOAD EN 12825
1
2
3
4
5
Transpack Group Service S.p.A. reserves the right to change technical data without notice
67
Rev. July 2010
Subtructure
MP
Super High slim
diGiT HEiGHT (mm) AdJUSTMENT coNfiGURATioN
RHM 1000-1600 ± 25mm Standard
3.3 Kg / m2 H = 1000 mm Extra weight for every further cm of height: 0.0102 Kg/cm
H mm 1000 1200 1400 1600
Kn(1) 25.00 18.00 12.00 6.50
DESCRIPTON RIF. MATERIAL PIECES m2
Head disk 1 Galvanized steel 3.3Tube Ø 25x1,2 approx. 2 Galvanized steel 3.3Nut M14 3 Galvanized steel 3.3Head with threaded rod M14 4 Galvanized steel 3.3Head gasket 5 Conductive polyethylene 3.3
TECHNICAL DATA
TOTAL WEIGHT
PEDESTAL AXIAL LOAD EN 12825
PEDESTAL AXIAL LOAD EN 12825
5 HEAD GASKET
4 HEAD WITH THREATED ROD M14
3 NUT M14
1 HEAD DISK
2 TUBE
THREATED ROD M14
68
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
ULTIMATE LOAD UNI 10467 (Deflection <= 2.5 mm; Safety factor = 2)
MECHANICAL RESISTANCE CHART OF STANDARD LINE SYSTEM
STRUCTURE MPS/MPL MPM/SSH MPH MPC/MPO Other characteristics
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN) REI Weight
each (kg) dB
PLNAM 1,00 7,50 1,50 1,50 10,00 2,10 2,30 16,00 2,50 2,80 19,00 3,00 30 ~8,5 ³30
PLNAV 1,70 12,00 2,50 2,20 16,00 2,90 3,30 22,00 3,50 4,30 26,00 4,50 15 ~10 ³30
PLTMM 2,00 13,00 2,70 2,60 17,00 3,00 3,60 23,00 3,70 4,20 27,00 4,50 45 ~10 ³32
PLTMV 3,00 21,00 4,00 3,50 23,00 4,40 4,50 31,00 4,70 5,00 35,00 5,00 30 ~11 ³32
PLTAV 3,30 21,00 4,50 3,80 23,00 4,50 4,70 31,00 5,00 5,20 35,00 5,30 30 ~12 ³32
PG6AM 2,40 18,00 3,20 3,10 22,00 3,70 3,80 28,00 4,30 4,20 32,00 5,00 60 ~17 ³34
PG6AV 4,00 20,00 5,30 4,50 25,00 5,80 5,20 30,00 6,40 5,60 35,00 7,90 45 ~18 ³34
PG3AM 3,00 23,00 4,00 3,50 27,00 4,40 4,50 31,00 5,10 5,00 35,00 5,40 90 ~19 ³38
PG3AV 5,00 29,00 6,50 5,50 34,00 7,00 6,00 39,00 7,50 6,50 45,00 8,00 60 ~20 ³38
PW4AM 2,30 16,00 3,50 2,70 19,00 4,00 3,20 25,00 4,70 4,00 30,00 5,50 60 ~14 ³34
PW4AV 3,30 16,00 3,50 3,80 19,00 4,00 4,20 25,00 4,70 5,00 30,00 5,50 60 ~14 ³34
PANELS
LOAD
NOTE:For Finished Floor Height FFH more than 750 mm, please verify the real operating condition of the System.
Load position are given as follows:S=on any point of the systemC=centre of the panel
69
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
MPS= without stringers, MPL= light stringers, MPM/SSH= medium stringers, MPH/MPO/MPC= high resistance special stringers
ULTIMATE LOAD UNI 10467 (Deflection <= 2.5 mm; Safety factor = 2)
MECHANICAL RESISTANCE CHART OF HIGH CLASS SYSTEM
NOTE:For Finished Floor Height FFH more than 750 mm, please verify the real operating condition of the System.
Load position are given as follows:S=on any point of the systemC=centre of the panel
STRUCTURE MPS/MPL MPM/SSH MPH MPC/MPO Other characteristics
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN) REI Weight
each (kg) dB
PLTMMHCeramic 60x60 2,50 17,00 3,50 3,00 20,00 3,40 4,00 25,00 4,10 4,50 30,00 5,30 45 ~19 >32
PLTMVHCeramic 60x60 3,80 25,00 5,50 4,60 29,00 5,80 5,10 33,00 6,30 6,10 36,00 7,40 30 ~20 >32
PLTMMH/TCeramic 30x30 2,00 13,00 2,70 2,60 17,00 3,00 3,60 23,00 3,70 4,20 27,00 4,50 45 ~19/21 >32
PLTMVH/TCeramic 30x30 3,00 21,00 4,50 3,50 23,00 5,50 4,50 31,00 5,50 5,00 35,00 6,50 30 ~20/22 >32
PG2AVHCeramic 60x60 3,10 20,00 4,10 3,30 23,00 4,30 4,60 30,00 4,90 5,10 35,00 5,90 45 ~19 ³30
PG2AVH/TCeramic 30x30 2,10 20,00 3,50 2,70 23,00 3,80 3,60 30,00 4,30 4,10 35,00 5,40 45 ~19/21 ³30
PG6AMHCeramic 60x60 3,00 12,00 4,00 3,60 16,00 4,50 4,00 21,00 4,80 4,60 26,00 5,10 60 ~24 >34
PG6AMH/TCeramic 30x30 2,40 12,00 3,40 3,10 16,00 3,70 3,80 22,00 4,20 4,20 26,00 4,70 60 ~24/26 >34
PG6AVHCeramic 60x60 5,00 21,00 7,40 5,20 25,00 7,70 5,70 31,00 7,90 6,20 35,00 8,10 45 ~25 >34
PG6AVH/TCeramic 30x30 4,00 20,00 7,10 4,50 25,00 7,40 5,20 31,00 7,50 5,60 35,00 7,70 45 ~25/27 >34
PG3AMHCeramic 60x60 3,60 24,00 4,60 4,40 28,00 5,10 4,90 33,00 5,50 5,60 37,00 5,80 90 ~26 >38
PG3AVHCeramic 60x60 5,80 33,00 7,50 6,10 37,00 7,80 6,60 41,00 8,00 7,10 46,00 8,10 60 ~27 >38
PG3AMH/TCeramic 30x30 3,00 24,00 4,00 3,50 28,00 4,40 4,50 33,00 5,00 5,00 37,00 5,10 90 ~26/28 >38
PG3AVH/TCeramic 30x30 5,00 33,00 7,30 5,50 37,00 7,60 6,00 41,00 7,80 6,50 46,00 8,00 60 ~27/29 >38
PANELS
LOAD
STRUCTURE MPS/MPL MPM/SSH MPH MPC/MPO Other characteristics
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN) REI Weight
each (kg) dB
PG1AVZ 2,20 16,00 3,30 2,50 18,00 3,70 3,50 22,00 4,00 4,50 27,00 4,50 45 ~27 >30
PG2AVZ/Q 3,50 20,00 4,10 3,70 23,00 4,30 4,60 30,00 4,90 5,10 35,00 5,90 45 ~25 >34
PLTMMW 2,00 13,00 2,70 2,60 17,00 3,00 3,60 23,00 3,70 4,20 27,00 4,50 45 ~11 >32
PLTMVW 3,00 21,00 4,00 3,50 23,00 4,40 4,50 31,00 4,70 5,00 35,00 5,00 30 ~12 >32
PG6AMW 2,40 18,00 3,20 3,10 22,00 3,70 3,80 28,00 4,30 4,80 32,00 5,00 45 ~17 ³34
PG6AVW 4,00 20,00 5,30 4,50 25,00 5,80 5,40 30,00 6,40 5,80 35,00 7,90 45 ~18 >34
PG3AMW 3,00 23,00 4,00 3,50 25,00 4,40 4,50 31,00 5,10 5,00 35,00 5,40 90 ~20 >38
PG3AVW 5,00 29,00 6,50 5,50 34,00 7,00 6,00 39,00 7,50 6,50 45,00 8,00 60 ~21 >38
PW4/PF4AMW 2,30 16,00 3,50 2,70 19,00 4,00 3,20 25,00 4,70 4,00 30,00 5,50 60 ~15 >34
PBAT/PBAO 2,00 13,00 2,70 2,60 17,00 3,00 3,60 23,00 3,00 4,20 27,00 3,00 - ~22 -
PANELS
LOAD
70
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
ULTIMATE LOAD UNI 10467 (Deflection <= 2.5 mm; Safety factor = 2)
MECHANICAL RESISTANCE CHART OF METAL LINE SYSTEM
NOTE:For Finished Floor Height FFH more than 750 mm, please verify the real operating condition of the System.
Load position are given as follows:S=on any point of the systemC=centre of the panel
STRUCTURE MPS/MPL MPM/SSH MPH MPC/MPO Other characteristics
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN)
Conc. S. (kN)
Distributed (kN/m2)
Conc. C.(kN) REI Weight
each (kg) dB
PLNAR0 2,30 17,50 3,50 3,60 23,00 4,20 4,00 25,00 4,70 4,50 29,50 4,90 15 ~10 ≥30
PLTMR0 3,80 24,00 4,40 4,60 26,00 5,10 5,00 34,00 6,00 6,00 39,00 7,00 30 ~12.5 ≥30
P30SS/W 2,00 13,00 3,00 2,60 17,00 3,30 3,60 23,00 3,50 4,20 27,00 3,50 - ~13.5/15.5 -
PLTMMF 2,20 24,00 2,70 2,80 26,00 3,00 3,80 26,00 3,70 4,40 34,00 4,50 45 ~11.5 ≥32
PG6AR0 3,80 20,00 3,20 4,60 25,00 3,70 5,00 30,00 4,30 6,00 35,00 5,00 60 ~19 ≥34
PG3AR0 5,00 29,00 4,00 5,50 34,00 4,40 6,00 39,00 5,10 6,50 45,00 5,40 90 ~19 ≥38
PANELS
LOAD
71
Rev. July 2010Transpack Group Service S.p.A. reserves the right to change technical data without notice
Transpack Group Service S.p.A.Headquarters - Via dell’industria, 19 - 21 35028 Piove di Sacco (Pd) - italy - Tel. +39.049.9713311
Sales Office & Showroom - Via San Marco, 1135129 Padova - italy - Tel. +39.049.8072536
Registered office - Via dante, 4235029 Pontelongo (Pd) - italy - fax +39.049.9713313
UAE Branch floor System companyP.o. Box 49161 - Hamriyah free Zone Sharjah - UAETel. +971 (6) 5269002 - fax +971 (6) 5269003
[email protected] - www.nesite.com