MOTOR INSTALLATION Knowledge of proper installation techniques is vital to the effective operation of a motor

MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

  • Upload
    ngoque

  • View
    228

  • Download
    3

Embed Size (px)

Citation preview

Page 1: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

MOTOR INSTALLATION

Knowledge of proper installation

techniques is vital to the effective

operation of a motor

Page 2: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• I. Foundation

– Rigid foundation is essential for minimum

vibration and proper alignment between

motor and load

– Concrete --- best foundation for large

motors and driven loads

Page 3: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• II. Mounting

– Motors can be mounted in any position or

angle unless specified otherwise

– Must be mounted securely to the

mounting base of equipment or to a rigid

flat surface

– An adjustable motor base makes the

installation, tensioning, and replacements

of belts easier

Page 4: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• Common types of Motor Mountings

Page 5: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• Common types of Motor Mountings– Rigid base

• Bolted, welded, or cast on the mainframe

• Allows the motor to be rigidly mounted on equipment

– Resilient base• Has isolation or resilient rings between motor

mounting hubs and base to absorb vibration and noise

• A conductor is imbedded in the ring to complete the circuit for grounding purposes

Page 6: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• Common types of Motor Mountings

– NEMA C face mount

• Has a machine face with a pilot on the shaft

end that allows direct mounting with a pump

or other direct-coupled equipment

• Bolts pass through mounted part to threaded

hole in the motor face

Page 7: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• III. Motor and Load Alignment

– Misalignment between motor shaft and

load shaft causes unnecessary vibration

and failure due to mechanical problems

– Premature bearing failure in the motor

and/or load can result from misalignment

– Direct-drive motors

• supply torque and speed to the load directly

Page 8: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• III. Motor and Load Alignment

– Coupling by means of gears or

pulleys/belts

• used in cases where the application requires

other than standard available speed

• Variable speed are possible by making

available several gear ratios

Page 9: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures• III. Motor and Load Alignment

– Formula to calculate speed and pulley sizes for belt-drive systems

Problem: You have a motor to drive a load. The motor operates at 1,725 rpm and has a pulley with 2 inch diameter; the load must operate at 1,150 rpm. What size of pulley is needed for the load

DiameterPulleyMotor

DiameterPulleyEquipment

RPMEquipment

RPMMotor

Page 10: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• IV. Motor Bearings

Page 11: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• IV. Motor Bearings

– Rotating shaft of a motor is suspended in

the end bells by bearings that provide a

relatively rigid support for the output shaft

– Sleeve bearings

• Used on smaller light-duty motors

• Consists of a bronze or brass cylinder, a wick,

and a reservoir

Page 12: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• IV. Motor Bearings– Ball Bearings

• are the most common type of bearing.

• carry heavier loads and can withstand severe applications.

– Roller Bearings• used in large motors for belted loads.

• the roller is a cylinder, so this spreads the load out over a larger area, allowing the bearing to handle much greater loads than a ball bearing.

Page 13: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• IV. Motor Bearings

– Thrust Bearings

• consist of two thrust races and a set of rollers

that are designed to handle higher than

normal axial forces exerted on the shaft of the

motors, as is the case with some fan and

pump blade applications.

• Motors for vertically mounted motors typically

use thrust bearings.

Page 14: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• V. Electrical Connections

• The motor must be connected to a power source corresponding to the voltage and frequency rating shown on the motor nameplate.

• Stator winding connections should be made as shown on the nameplate connection diagram or in accordance with the wiring diagram attached to the inside of the conduit box cover

Page 15: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• VI. Grounding

• Both your motor and the equipment or

apparatus to which it is connected

must be grounded as a precaution

against the hazards of electrical shock

and electrostatic discharge

Page 16: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• VII. Conductor Size

• The size of the motor branch circuit

conductors is determined in accordance

with the NEC, based on the motor full-

load current, and increased where

required to limit voltage drop.

• Undersized wire between the motor and

power source will limit stating abilities and

cause overheating of the motor

Page 17: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,
Page 18: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,
Page 19: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

Page 20: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• VII. Conductor Size

• What size THW CU conductors are

required for a single 15-hp, three-

phase, 230-V squirrel-cage motor?

Page 21: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• VIII. Voltage Levels and Balance

• Motor voltages should be kept as close to the nameplate value as possible, with a maximum deviation of 5 percent.

• Although motors are designed to operate within 10 percent of nameplate voltage, large voltage variations can have negative effects on torque, slip, current, efficiency, power factor, temperature, and service life.

Page 22: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures• VIII. Voltage Levels and Balance• Unbalanced motor voltages applied to

a polyphase induction motor may cause unbalanced currents, resulting in overheating of the motor’s stator windings and rotor bars, shorter insulation life, and wasted energy in the form of heat.

• When three-phase line voltages are not equal in magnitude, they are said to be unbalanced.

Page 23: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures• VIII. Voltage Levels and Balance• A voltage unbalance can magnify the percent

current unbalance in the stator windings of a motor by as much as 6 to 10 times the percent voltage unbalance.

• Acceptable voltage unbalance is typically not more than 1 percent.

• When there is a 2 percent or greater voltage unbalance, steps must be taken to determine and rectify the source of the unbalance. In cases where the voltage unbalance exceeds 5 percent, it is not advisable to operate the motor at all.

Page 24: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• VIII. Voltage Levels and Balance

• Problem: What is the percent voltage

unbalance for a three-phase supply

voltage of 480 V, 435 V, and 455 V?

Page 25: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,
Page 26: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures• IX. Built-in Thermal Protection• Overload relays mounted on the motor starter enclosure

protect the motor by monitoring the motor current and resultant heat it creates inside the motor. They do not, however, monitor the actual amount of heat generated within the winding. Motors subject to such conditions as excessive starting cycles, high ambient motor temperatures, or inadequate ventilation conditions may experience rapid heat buildup that is not sensed by the overload relay. To minimize such risks, the use of motors with thermal protectors inside that sense motor winding temperature is advisable for most applications. These devices may be integrated into the control circuit to offer additional overload protection to the motor or connected in series with the motor windings on smaller single-phase motors

Page 27: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• IX. Built-in Thermal Protection

• Basic Types:

Page 28: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• IX. Built-in Thermal Protection

• Basic Types:

• Automatic reset: After the motor

cools, this line-interrupting protector

automatically restores power. It should

not be used where unexpected

restarting would be hazardous.

Page 29: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• IX. Built-in Thermal Protection

• Basic Types:

• Manual reset: This line-interrupting protector has an external button that must be pushed to restore power to the motor. Use where unexpected restarting would be hazardous, as on saws, conveyors, compressors, and other machinery.

Page 30: MOTOR INSTALLATION - · PDF fileMOTOR INSTALLATION Knowledge of proper ... against the hazards of electrical shock ... overheating of the motor’s stator windings and rotor bars,

Important Installation

Procedures

• IX. Built-in Thermal Protection

• Basic Types:

• Resistance temperature detectors: Precision-calibrated resistors are

mounted in the motor and are used in

conjunction with an instrument to

detect high temperatures.