8
04-2006 DKCFN.PD.040.A2.02 521B0820 Nessie ® is a trademark of Danfoss A/S Data Sheet Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge" Generally The Nessie ® 3/2 way valves have in particular been designed for applications in high-pressure humidification and adiabatic cooling systems. Each valve has an IN, OUT and DRAIN port. When the valve is not in operation the connection between IN and OUT is closed while the connection between OUT and DRAIN stays open. This allows to instantaneously relief the pressure at shut down from the application, typically a nozzle branch, to prevent the nozzles from dripping. If desired, the nozzle branch can be entirely drained after shut down to avoid bacterial growth. Furthermore, each valve has its individual properties to match exactly the specific needs in size and functionality. All Nessie valves are made of stainless steel (AISI 304) and are suitable for potable and technical water. They have an extremely long service life for at least one million operations and are even then very easy to service. Inline valves are available with European BSP thread (G-thread) and American National Pipe Thread (NPT). For the VDHT 15EC and VDH 30EC Danfoss offers a wide range of single and multiple manifolds. The enclosure rating is IP 67, including any standard solenoid coil. A large variety of coils for various supply voltages is available for all Nessie valves.

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E ...literature.puertoricosupplier.com/~Pending~/WV17966.pdf · DKCFN.PD.040.A2.02 521B0820 3 Data Sheet Nessie 3/2-Way Zone-Drain-Valves

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E ...literature.puertoricosupplier.com/~Pending~/WV17966.pdf · DKCFN.PD.040.A2.02 521B0820 3 Data Sheet Nessie 3/2-Way Zone-Drain-Valves

04-2006 DKCFN.PD.040.A2.02521B0820 Nessie®isatrademarkofDanfossA/S

Data Sheet

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC andVDH 30EC "Soft-Charge"

Generally TheNessie®3/2wayvalveshaveinparticularbeendesignedforapplicationsinhigh-pressurehumidificationandadiabaticcoolingsystems.EachvalvehasanIN,OUTandDRAINport.WhenthevalveisnotinoperationtheconnectionbetweenINandOUTisclosedwhiletheconnectionbetweenOUTandDRAINstaysopen.Thisallowstoinstantaneouslyreliefthepressureatshutdownfromtheapplication,typicallyanozzlebranch,topreventthenozzlesfromdripping.Ifdesired,thenozzlebranchcanbeentirelydrainedaftershutdowntoavoidbacterialgrowth.Furthermore,eachvalvehasitsindividualpropertiestomatchexactlythespecificneedsinsizeandfunctionality.

AllNessievalvesaremadeofstainlesssteel(AISI304)andaresuitableforpotableandtechnicalwater.Theyhaveanextremelylongservicelifeforatleastonemillionoperationsandareeventhenveryeasytoservice.

InlinevalvesareavailablewithEuropeanBSPthread(G-thread)andAmericanNationalPipeThread(NPT).FortheVDHT15ECandVDH30ECDanfossoffersawiderangeofsingleandmultiplemanifolds.

TheenclosureratingisIP67,includinganystandardsolenoidcoil.AlargevarietyofcoilsforvarioussupplyvoltagesisavailableforallNessievalves.

Page 2: Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E ...literature.puertoricosupplier.com/~Pending~/WV17966.pdf · DKCFN.PD.040.A2.02 521B0820 3 Data Sheet Nessie 3/2-Way Zone-Drain-Valves

2 DKCFN.PD.040.A2.02 521B0820

Data Sheet Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Generally(continued)

TheVDM2Eisaverysmallandcompactvalveforminorflowratesupto1.8litresperminute(0.5gpm).Itisadirectoperatedtypeofvalvewithjustonecoil.Itissuitableforsystemswithmanyzoneswithfewnozzlesandisaverycosteffectivesolution.

TheVDHT15Eisamediumsizesingleinlinevalveforflowratesupto15litresperminute(4gpm).ItisbasedonthelatestNessievalvetechnology,comprisingapistontypeNCvalveandaNOpilotstageinonehousing.Itcoversaverywideflowrangealreadystartingfrom1litreperminute(0.26gpm)andistheidealsolutioninsteadofusing2separatevalves(1NCand1NO).TheVDHT15Erequires2solenoidsactivatedbyacommonsignal(i.e.24VAC).

TheVDHT15EC3/2istheCetop3variantoftheVDHT15E,bymeansthatconnectionsaremadethroughavalveblockormultiplevalvemanifold.Inmultiplevalveapplicationsupto5valvescanbeinstalledonacommonmanifoldsidebyside,savingtime,spaceandplumbingeffort.

TheVDH30ECisahighlydedicatedvalvefordemandingapplications,i.e.withlongpiperunsorverylargeflowratesupto30l/min(8gpm).ItconsistsofoneNCandoneNOpilotoperatedpistontypevalveinonehousing.Averyspecialfeatureofthisvalveisthesocalled“Soft-Charge”functionality;whenoperatingthetwosolenoidcoilswithatimedelay,thevalveworksasaflowdivider,allowingtofilltheapplicationpipesatareducedflowrate(lesspressure).Therewithwaterhammeringandpressureshocksatswitch-onandshut-offcanbeeliminated.Furthermore,thevalveispreparedforindividualadjustmenttoacertainflowrate;byinsertinganorificeintheOUT(B-)orDRAIN(T-)-porttheflowdiversioncanbemanipulated.

Page 3: Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E ...literature.puertoricosupplier.com/~Pending~/WV17966.pdf · DKCFN.PD.040.A2.02 521B0820 3 Data Sheet Nessie 3/2-Way Zone-Drain-Valves

DKCFN.PD.040.A2.02521B0820 3

Data Sheet Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

TheHVACblocksareespeciallydesignedforinductapplicationswhereanadditionalflushvalveinstalledontheblockallowstoflushthesystemforimprovedhygiene.3differenttypesareavailablefor1,2or3VDHT15ECorVDH30ECplusoneadditional2/2-wayVDHTflushvalve.Theblockscompriseonecommonconnectionforthepressurelinefromthepumpstationandonecommondrainportforpressurereliefandflushing.Foreachdischargeanoutletportisavailable.TheHVACblockisaverycostefficientsolutioni.e.inin-ductsystemswith6-stepvalvecontrol.EachVDH/VDHTvalveisoperatedbytwocoils(NCandNO),whiletheflushvalveisasinglecoilNCvalve.Pleasealsorefertothelistofcodenumbersonpage5.

Picture fully equipped blocks 1+1, 2+1 and 3+1

HVAC Block

Sub-base valve manifolds Danfossofferssub-basemanifoldsforinstalling3,4or5VDH/VDHT3/2wayvalvessidebyside.JustastheHVACblocks,thesub-basemanifoldsrepresentaverycostefficientsolution,savingsignificantlyontime,spaceandplumbingeffort,asthenumberofconnectionsisminimized.

Picture sub-base manifolds and simple inline block

Bothmultiplevalveconceptsareveryservicefriendlyasthevalvescanindividuallybedetachedfromthemanifoldforservicewithinafewminutes.VDHT15ECvalvescanbeservicewhileinstalledontheblock.

Allmanifoldscanbeconnectedfrombothsides,allowingahighlevelofflexibilityforplacingthemi.e.directlyonthepumpingstation.ForaspareblockpositionDanfossoffersabindplatetocovertheconnectionswhennotinuse.

TheHVACblockandthemultiplevalvemanifoldsareinterconnectable,i.e.insystemswithmorethan5valves.Danfossrecommendsbondedsealfittingsforallconnections.

Page 4: Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E ...literature.puertoricosupplier.com/~Pending~/WV17966.pdf · DKCFN.PD.040.A2.02 521B0820 3 Data Sheet Nessie 3/2-Way Zone-Drain-Valves

4 DKCFN.PD.040.A2.02 521B0820

Data Sheet Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

3/2-way principle

Soft-Charge principle

Technical Data

Solenoidcoil(s)de-energized Solenoidcoilsenergized

Bothcoilsde-energized NCcoilenergizedonly Bothcoilsenergized

P-port(IN)closed, P-,T-andB-port P-andB-port(INandB-andT-portconnected (IN,OUTandDRAIN) OUT)connected,T-port(OUTandDRAIN),application connected;flowpartially (DRAIN)closed,fullflowpipedrained toapplicationanddrain toapplication

Pressure losses at different flows

VDM 2E VDHT 15E VDHT 15 EC VDH 30 EC

Max.continuousinletpressureinbar/psi 80/1150 140/2000 140/2000 140/2000Max.peakinletpressureinbar/psi 100/1450 160/2300 160/2300 160/2300Min.operationpressureatINportinbar/psi 0 2/29 2/29 5/73Drainopeningpressureinbar/psi 80/1150 80/1150 80/1150 140/2000Max.flowINtoOUTinl/min/gpm 1.8/0.5 15/4 15/4 30/8Min.flowINtoOUTinl/min/gpm 0 1/0.26 1/0.26 2/0.53Max.flowtoDRAINinl/min/gpm 0.3/0.08 5/1.3 5/1.3 30/8Opening/closingtimeinms 250 250 250 150Max.watertemperaturein°C/°F 50/122 50/122 50/122 50/122Servicelife min1millionoperationsWeightwithoutcoil(s)inkg/lbs 1.1/2.4 1.5/3.5 1.5/3.5 2.7/6

VDM2E3/2 VDHT15E3/2,VDHT15EC3/2

VDH30EC3/2

Page 5: Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E ...literature.puertoricosupplier.com/~Pending~/WV17966.pdf · DKCFN.PD.040.A2.02 521B0820 3 Data Sheet Nessie 3/2-Way Zone-Drain-Valves

DKCFN.PD.040.A2.02521B0820 5

Data Sheet Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Code Numbers

Water Quality, Filtration

Installation

AlltypesofNessievalvesaresuitableforoperationwithpotablewaterortechnicalwatersuchasreverseosmosiswater,de-mineralisedwaterorde-ionisedwater.

Thewatermustbefilteredtoaminimumof10μmabsolute.

Valvesandblocks Code numberVDM2EG¼” 180L3006VDM2E¼”NPT 180L3007VDHT15EG3⁄8,3⁄8,¼” 180L0173VDHT15E3× 3⁄8”NPT 180L0174VDHT15EC(Cetop3) 180L0240VDH30EC(Cetop3) 180L0051Singlein-lineblockG3⁄8”forVDHT15ECorVDH30EC 180L0200Singlein-lineblock3⁄8”NPTforVDHT15ECorVDH30EC 180L0201HVACblock1+1(1valve+flushvalve) 180L0181HVACblock2+1(2valves+flushvalve) 180L0182HVACblock3+1(3valves+flushvalve) 180L0183VDHT30ECNC2/2-way(flushvalve) 180L0096Sub-basemanifoldfor3VDHT15EC/VDH30EC 180L0261Sub-basemanifoldfor4VDHT15EC/VDH30EC 180L0262Sub-basemanifoldfor5VDHT15EC/VDH30EC 180L0263Blindplate(tocoverspareposition) 180L0079

Coils SupplyVoltage Power Code number

Standardclip-oncoilsNC+NO

24V/50Hz220V/50Hz240V/50Hz24V/60Hz

110V/50/60Hz220V/60Hz240V/60Hz

10W10W10W10W10W10W10W

018F7920018F7921018F7924018F7922018F7923018F7925018F7926

ULRecognized(UR)coilsNC+NO24V/50/60Hz

110V/50/60Hz208-240V50/60Hz

14W14W14W

018F7907018F7909018F7908

PlugforURcoilswithDINspade allvoltages 180Z0183

Service parts Code numberServicekitforVDM2E 180Z0041PistonkitforVDHT15ENC 180Z0015PistonkitforVDH30ECNC+NO 180L5005

TheVDM2EandVDHT15Ecanbemountedself-supportingbythepipesorcanbemountedwith2boltstoanysurface(seebelow).

TheVDHT15ECandVDH30ECareinstalledaccordingtotheCetopstandard.4boltsandO-ringsforblockmountingaresuppliedwiththevalve.

Page 6: Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E ...literature.puertoricosupplier.com/~Pending~/WV17966.pdf · DKCFN.PD.040.A2.02 521B0820 3 Data Sheet Nessie 3/2-Way Zone-Drain-Valves

6 DKCFN.PD.040.A2.02 521B0820

Data Sheet Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Dimensions, mm (in)

VDHT 15E3/2

VDM 2E3/2

VDHT 15EC

Page 7: Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E ...literature.puertoricosupplier.com/~Pending~/WV17966.pdf · DKCFN.PD.040.A2.02 521B0820 3 Data Sheet Nessie 3/2-Way Zone-Drain-Valves

DKCFN.PD.040.A2.02521B0820 7

Data Sheet Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Dimensions, mm (in)VDH 30EC3/2

HVAC Blocks 1+1, 2+1 and 3+1

Page 8: Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E ...literature.puertoricosupplier.com/~Pending~/WV17966.pdf · DKCFN.PD.040.A2.02 521B0820 3 Data Sheet Nessie 3/2-Way Zone-Drain-Valves

8 DKCFN.PD.040.A2.02521B0820 ProducedbyDanfossIndustriService-Advertising06.02.BPV.E

Data Sheet Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies toproducts already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Dimensions, mm (in)– Manifolds

Multiple blocks for 3, 4 and 5 valves VDHT/VDH