12
New results from CLAS12 forward resistive Micromegas produced by CIREA/ELVIA and CERN Gabriel CHARLES

New results from CLAS12 forward resistive Micromegas produced by CIREA/ELVIA and CERN

  • Upload
    jeanne

  • View
    30

  • Download
    0

Embed Size (px)

DESCRIPTION

New results from CLAS12 forward resistive Micromegas produced by CIREA/ELVIA and CERN . Gabriel CHARLES. New results from CLAS12 forward resistive Micromegas built by ELVIA and CERN. Collaboration with ELVIA Geometry of the detector and first measurements - PowerPoint PPT Presentation

Citation preview

Page 1: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

New results from CLAS12 forward resistive Micromegas produced by

CIREA/ELVIA and CERN

Gabriel CHARLES

Page 2: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

G. Charles Workshop RD51, 24/04/2013 0

New results from CLAS12 forward resistive Micromegas built by ELVIA and CERN

Collaboration with ELVIA

Geometry of the detector and first measurements

Tests with a cosmic bench

Conclusions

Page 3: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

G. Charles Workshop RD51, 24/04/2013 1

Micromegas production at CIREA

Conclusion slide by D. Neyret for the previous RD51 mini-week

Page 4: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

Forward Micromegas for CLAS12

G. Charles Workshop RD51, 24/04/2013 2

Specifications :• active area : 430 mm diameter disk with a 50

mm diameter hole at the center• PCB thickness less than 100 µm and glued on

ROHACELL• 500 µm pitch, with 100 µm between two strips• resistive strips à la Joerg

Gerber view

Prototype by CIREA

Central zone

Prototype by CERN

Two prototypes tested

Page 5: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

Strip resistivity for the CERN prototype

G. Charles Workshop RD51, 24/04/2013 3

The resistivity was measured in more than 400 points on a non-bulked PCB

Strip 0

Strip 960

0 100 200 300 400 500 600 700 800 900 10000

50

100

150

200

250

300

350

Center external

Center external

External

Internal

Internal

External

Strip number

Resis

triv

ity [M

Ω]

Strip 290

Ground

strip

Courtesy : D. Attié

Page 6: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

Cosmic test bench

G. Charles Workshop RD51, 24/04/2013 4

• The two forward prototypes have been tested

• For both, more than 500,000 triggers have been recorded

• For each trigger, when a cluster is reconstructed in all the reference detectors, the track is interpolated to the prototype

• The position interpolated is then compared to the cluster reconstructed in the detector under test

Page 7: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

<S/N> ~ 140 at Vmesh = 450 V

First tests

G. Charles Workshop RD51, 24/04/2013 5

<S/N> ~ 150 at Vmesh = 460 V

• No leakage current after one day

• Excellent S/N ratio• Other variables consistent

with standard Micromegas

Page 8: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

Efficiencies

G. Charles Workshop RD51, 24/04/2013 6

Prototype by ELVIA

• Central zone not connected (forget hole in the drift)

• Lower efficiency on the top left part of the detector

Prototype by CERN

• Excellent efficiency on almost all the detector

• Low efficiency on the top left part of the detector

Page 9: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

Efficiencies

G. Charles Workshop RD51, 24/04/2013 6b

Prototype by ELVIA

Prototype by CERN

• Central zone not connected (forget hole in the drift)

• Lower efficiency on the top left part of the detector

• Efficiency around 90%

• Excellent efficiency on almost all the detector

• Low efficiency on the top left part of the detector

• Efficiency better than 90% almost everywhere

Page 10: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

Gain

G. Charles Workshop RD51, 24/04/2013 7

• The two detectors have lower gain both at the same position

• Just a coincidence ? A gas leak ? Switch gas entrance and exit to check

• About gas circulation : the design will be soon finalized, simulations by finite elements are ongoing

! Amplification gaps are different.

ELVIA CERN

Same fields for

both detectors

Page 11: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

Tests under X-ray generator

G. Charles Workshop RD51, 24/04/2013 8

Courtesy : C. Lahonde-Hamdoun and S. Procureur

Preliminary conclusion : there is no saturation at 1 MHz per cm².

Page 12: New results from CLAS12 forward resistive  Micromegas  produced by  CIREA/ELVIA  and CERN

Conclusions and perspectives

G. Charles Workshop RD51, 24/04/2013 9

Large size resistive MM by CIREA• Production without problem• Prototype tested in cosmic bench and under X rays• Normal behavior under cosmic rays : no leakage

current

First results on performances• Very good efficiency• No sign of saturation yet with X-rays• Next CLAS12 resistive may have lower resistivity

Next steps with ELVIA• Test of forward prototypes of resistive MM made by

serigraphy by ELVIA • Test of small (6x10 cm² active area) prototypes with

buried resistors for COMPASS• Large size (40x40 cm²) non-simplified prototype for

COMPASS

500 µm