Upload
ivory
View
57
Download
3
Tags:
Embed Size (px)
DESCRIPTION
Planmeca ProOne. The best choice for dental office. The best choice for dental office. The best choice for dental office. Easy to operate Open and easy patient access Side entry and open view No mirror, no traumatic view of injuries Triple laser beam system for accurate alignment. - PowerPoint PPT Presentation
Citation preview
Planmeca ProOne
The best choice for dental office
The best choice for dental office
The best choice for dental officeEasy to operateOpen and easy patient access
Side entry and open view •No mirror, no traumatic view of injuries
Triple laser beam system for accurate alignment
Intuitive controls
• Graphic User Interface (GUI) for intuitive and cognitively ergonomic selection of the wanted program and exposure parameters.
Clear and sharp images
•The focal layer shape is based on scientific study on human jaw shape
3 different sizes x 3 different forms = 9 different focal layers
•Constant magnification
Clear access for all patients
•Wheelchair patients•Patient in hospital bed •Children can see the accompanying parent
Clear and sharp imagesThe path of the rotating centre of the radiation beam influences the image quality
Long path starting and ending well outside the jaw
Less radiation Less shadowsPlanmeca ProOne images have no ghost shadows
High diagnostic quality even in cases with metallic items in the object
Elimination of the cervical column shadow by reduced rotation speed at the central incisor region
Uniform darkness, and contrast
Reliable solutionsSimple mechanical construction
No mechanical control buttons
Minimised amount of PCB's and cables
Latest universal components
Reliable Effortless and fast to service
Autofocus
• Positions the focal layer automatically
• Takes first short lateral exposure
• A special algorithm find the jaw form and place and calculates the optimal location of the layer
Dynamic Exposure Control
Exposure Parameter Control Adjusts the exposure parameters optimal
for each patient automatically Prevents too low initial exposure
parameters from causing under-exposure and/or poor image quality
Prevents unnecessary high radiation levels
Automatic Gain Control Adjusts the sensitivity of the sensor
according to the amount of incoming radiation
Adapts automatically to patient anatomy Prevents pixel saturation even in soft
tissue and direct radiation areas Works in all programs
exposure control
dynamic gain control
= Exposure Parameter Control + Automatic Gain Control
Functional exposure programs• Panoramic programs:Standard panoramic program *Child panoramic program *Interproximal program **Orthogonal program **Bitewing program **
* incl. in basic programs
**incl. in advanced programs
Panoramic programsStandard panoramic program
•Normal path of the beam•Standard focal layer
Paediatric program•Traditional path of the beam
•Narrow focal layer•Reduces patient dose 35%
Panoramic programsOrthogonal panoramic programX-ray beam perpendicular to the jaw
extremely valuable for implant planning
helps to see crestal alveolar bone height to diagnose periodontal disease
Interproximal panoramic program
the X-ray beam and the interproximal contacts of the teeth are parallel
the teeth do not overlapextremely useful for caries detection
Interproximal programstandard panoramic interproximal panoramic
Normal panoramic geometry•teeth are overlapping
Geometry improved according to the teeth interproximal angulation
•no overlapping
Bitewing panoramic programBitewing Panoramic Program
•Produces bitewing like images from premolar and molar areas including parts of maxilla, mandible and rami.
•Ideal for caries diagnosis
•The bottom of the maxillary sinus and as well the mandibular canal and the mental foramen are also visible
•Uses interproximal projection geometry
•50% dose reduction compared to the normal panoramic program
Panoramic programs•Vertical and horizontal segmenting
limited exposure of the diagnostically interesting area
minimum radiation to patient
reduces the patient dose up to 80%
Functional exposure programs
•TMJ programsDouble Lateral TMJ program *Double PA TMJ program *Double Latera- PA TMJ program**Lateral 3 angles TMJ program (left or right) **
* incl. in basic programs
**incl. in advanced programs
TMJ programs
Lateral double TMJ
PA double TMJ
TMJ programs
Lateral-PA double TMJ
Lateral 3 angles TMJ
Functional exposure programs
•Sinus programs:PA-rotational sinus program *Lateral sinus program (left or right) ** Lateral midsagittal sinus program (left or right) **
* incl. in basic programs
**incl. in advanced programs
Basic sinus program
PA sinus program
•Special focal layer
Advanced sinus programs
Lateral non-rotational sinus
Midsagittal lateral non-rotational sinus
Functional exposure programs
•Cross sections:Manual Cross Sections programAutomatic Cross Sections program
•incl. in advanced programs
Cross sections
•1-3 cross-sectional images (manual)
•3 cross sectional images (automatic)
•Provides cross-sectional images to examine basic anatomy
•Not suitable for implant planning
Program configurations1.Basic programs (standard):
Standard panoramic program, Child panoramic program Double Lateral TMJ program, Double PA TMJ program PA-rotational sinus program
2.Advanced programs (optional): Improved interproximality program, Improved orthogonality program, Bitewing
program Double Latera- PA TMJ program, Lateral 3 angles TMJ program (left or right) Lateral sinus program (left or right), Lateral midsagittal sinus program (left or
right) Manual Cross Sections program, Automatic Cross Sections program
3. Horizontal and vertical segmenting (optional)
4. DEC (Dynamic Exposure Control) (optional)
Planmeca Romexis Digital imaging software
•The software for capturing, viewing and processing the images
•Features powerful Image Browser allowing for access to images
•Includes a wide range of tools for image processing.
•Versatile functions for printing and reporting.
•Planmeca Romexis Viewer software guarantees that images from Planmeca Romexis can be fully utilised anywhere outside the clinic
The end• More information:• Erkki Hiltunen• Product Manager, X-rays• tel: +358 20 7795 456 • [email protected]
• Mark Niemi• Product Manager, X-rays• tel: +358 20 7795 743 • [email protected]
• www.planmeca.com
4/2011